E18-0151_Approved Plans_1533582069.pdf
O EQUIPMENTSCHEDULEWO OF 6,. TAG DESCRIPTION PARTNUMBER NOTES gli 1 PV MODULE LG 350 W MATED WITH SOLAR EDGE P370 OPTIMIZERS 2 PV ARRAY 24 MODULESX 2 TWO STRINGS OF 12 X 2 id Oro 3 3-BOX WET LOCATION DOUBLE GANG 4 DC DISCO N/A INTEGRAL TO INVERTER -ii •b 5 INVERTER SOLAR EDGE X2 SE7600A-US,UL1741,UL1699B,RAPID SHUTDOWN 4., 6 AC PANEL CUTLER HAMLER 100-A 71010a lei 7 AC DISCO 100-A SERVICE-RATED,UTILITYREADILY ACCESSIBLE,VISIBLE OPEN,LOCKABLE AND LABELED:PV AC DISCONNECT#1 08/06/18 8 SERVICE PANEL GE 240 VAC, 200A MAIN, 200A BUS 9 AC DISCO 100-A SERVICE-RATED,UTILITYREADILY ACCESSIBLE,VISIBLE OPEN,LOCKABLE AND LABELED:PV AC DISCONNECT#2 10 SERVICE PANEL GE 240 VAC, 200A MAIN, 200A BUS 0 M METER 240V,200A 0CO 0 © © DC DISCO INVERTER 0 • 00 0\ N A nC 12 MODULES IN SERIES nc 40A WITH SOLAR EDGE P370 A J-BOX i AC DISCO AC DISCO 12 MODULES IN SERIES lU n Supply WITH SOLAR EDGE P370 4 Side tap II DC DISCO INVERTER ••ED•.. 80AFuses � 00A Man •...� •.., %••• ••• . , ,v VE 12 MODULES IN SERIES ; 40A MAIN SERVICE WITH SOLAR EDGE P370 N ^ / PANEL .. .......� ,J 6 12 MODULES N SERIES WITH SOLAR EDGE P370 •• ' 1 ® ® 4 5 BUILDING GROUNDING 0 CONDUITANDCONDUCTORSCHEDULEIf 16.8 KW SOLAR PV SYSTEM TAG DESCRIPTIONOR CONDUCTOR TYPE COND. NUMBER OF CONDUIT CONDUIT 11 FLUSH MOUNTED TO ROOF 4 GAUGE CONDUCTORS TYPE SIZE 1 PV WIRE 10 4 N/A N/A BARECOPPEREGC 10 1 N/A N/A r „ [ { -1- 2 THWN-2 10 8 EMT 3/4" 13 u Carol& Michael Phillips THWN-2 EGC 10 I 2696 Davos Trail 3 THWN-2 8 6 EMT 3/4" SOLAR ELECTRIC Vail, Colorado 81657 THWN-2 GROUND 10 I 4 THWN-2 4 3 OFFSET 1" 722 Iowa Street DRAW NBY BKS CHECKED BY W VP THWN-2 GROUND 10 I _ Golden, CO 80403 5,6 THWN-2 4 3 EMT 3/4 303 903-9119 DATE:6/21/2017 REVA SHEET 1 OF 2 THWN-2 GROUND 10 I EMT Calculations 2 PV SOURCE CIRCUIT 9.7A X 1.56=15.132A,#10 THWN-2 =35A X 80%(conduit fill)=28A,Tempadder22 C (Conduit.5"to 3.5"offroof)=22C+41C=66C=.58 x 28 A=16.2 A,15.132A< 16.2A 4,5,6 INVERTER OUTPUT 32 A X 1.25 =40A OCPD No Temp Correction.#8 THWN-2=55A, 32A<55A L ABEL S(PER 2015 IFC 605.11.1 AO OF 6..4. 2017 AND NEC) , INVERTER/DC DISCO: NOTES: z. C in 47, WARNING ELECTRIC SHOCK HAZARD Cie eft. IF A GROUND FAULT IS INDICATED, .b NOR laili BE UNGROALLY OUNDEED CONDUCTORED AND ENERGIZEDMAY j-1010 08/06/18 DC DISCONNECT WARNING PV MODULERATINGS(STC) INVERTER RATINGS ELECTRICSHOCK HAZARD MODULE MAKE LGELECTRONICS INVERTER MAKE SOLAREDGE DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND MODULE MODEL 350 W INVERTER MODEL 7600TL-US LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION MAX POWER-POINTCURRENT(IMP) 9.7 MAX DC VOL TRATING 600 VDC MAX POWER-POINT VOL TAGE(VMP) 36.1 MAX POWER@ 40 DEG C 7400 W AC OPEN-CIRCUIT VOL TAGE(VOC) 42.7 NOMINAL AC VOL TAGE 240 VDC Peak Power:16.8 KW DC SHORT-CIRCUIT CURRENT(ISC) 10.77 MAX AC CURRENT 32.0 AAC Max Power Voltage:350 V DC MAX SERIES FUSE(OCPD) 20 MAX OCPD RATING 40 A AC Max Power Current:9.7 A DC Max Open Circuit Voltage:500 V MAXIMUMPOWER(PMAX) 350 Short Circuit Current:10.77 A MAX VOL TAGE 1000V SERVICE PANEL: VOC TEMP COEFF%/DegC -.28 WARNING: DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING INVERTER OUTPUT CONNECTION GROUNDING NOTES: DO NOT RELOCATE THIS OVERCURRENT DEVICE 1. Modules grounded together withUNIRACETL listedtop AC DISCO: mount grounding clamps. 2. Each module row connected SOLAR DISCONNECT to EGC with Tyco listed WARNING grounding device. ELECTRICSHOCK HAZARD 3.Module mounting rails are DO NOT TOUCH TERMINALS.TERMINALS NOT grounded. ON BOTH THE LINE AND LOAD SIDES 4. Grounded per 2017 NEC MAY BE ENERGIZED IN THE OPEN POSITION CONDUIT AND ENCLOSURES(PER 2015 IFC 5.11.1): WARNING: PHOTOVOLTAICPOWER SOURCE 4 0 d 4 16.8 KW SOLAR PV SYSTEM NET METER HOUSING: FLUSH MOUNTED TO ROOF PHOTOVOLTAIC SYSTEM 3 [J ( . I CONNECTED Carol& Michael Phillips 2696 Davos Trail PRODUCTION METER SOLAR ELECTRIC Vail, Colorado 81657 (PERXCEL ENERGY STANDARD SECTION4.14.4) Raised relief stamped in all-weather aluminum strip 722 Iowa Street DRAWN BY BKS CHECKED BY WVP PV PRODUCTION METER Golden, CO 80403 303 903-9119 DATE:6/21/2017 REV A SHEET 2 OF 2 2695 DAVOS TRAIL