Loading...
HomeMy WebLinkAboutF18-0047_approved documents_1532552838.pdf 75 South Frontage Road Fire-Construction Permit 0West, TOWN OF VAIL F18-0047 TOWN Vail,CO 81657 Issued: 07/25/2018 TOWN Or VAIL Office:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 551 N FRONTAGE RDW(210106302013) (210106302013 ) Unit#: Parcel Number: 210106302013 Legal Description: RED SANDSTONE ELEMENTARY SCHOOL Contacts Contact Type:Applicant Full Name:Jeremy Craig Address: 10864 W CoCo Place Littleton,CO 80127 Phone: 9703933242 Contact Type:Property Owner Full Name:EAGLE COUNTY SCHOOL DISTRICT RE-50J Address: Phone: None Contractor Contractor Type:Fire Protection Company: Assurance Fire Systems, Inc. State License#: 18-S-06113 Phone: 303-798-4448 Projecllnformation Project Name:Red Sandstone Elementary 2017 Project Description: Red Sandstone Parking Garage-install new dry pipe fire sprinkler system and new dry standpipe system Fees Paid Conditions Issued By:Town of V ailFireand Emergency Services Department NOTICE:By issuance of this Permitthe applicant agrees to complyto all Titles of the Town of Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicant shallforfeit all applicablefees. Fire and Emergency Services 2399 N. Frontage Road W. Vail, Colorado 81657 TOWN OF VA I L Tel: 970-479-2252 www.vailgov.com Fire& Emergency Services Fire Marshal FIRE SPRINKLER PERMIT Commercial & Residential Fire Alarm shop drawings are required at the time of application submittal and must include the following information: 1. A Colorado Registered Engineer's stamp or N.I.C.E.T level III (min)stamp 2. Equipment cut sheets of materials 3. Hydraulic calculations 4. A State of Colorado contractor registration number 5. Plans must be submitted by a Registered Fire Protection Contractor Project Street Address: Office Use: 551 N Frontage Road W Project#: (Number) (Street) (Suite#) Red Sandstone Garage Building Permit#: anone Building/Complex Name: g Sprinkler Permit#: Contractor Information: Lot#: Block# Subdivision: Company: Assurance Fire Systems Company Address: 10864 W CoCo Place Detailed Description of Work: Littleton CO80127 Install new Dry-pipe sprinkler system City: State: Zip: Jeremy Craig and dry standpipe system Contact Name: (use additional sheet if necessary) Contact Phone: 970-393-3242 E-Mail jcraig@assurancefiresystems.com Detailed Location of Work: I hereby acknowledge that I have read this application,filled out in full the information required, completed an accurate sprinkler sys- Does a Monitored Fire Alarm Exist? Yes( ) No tem working plan,and state that all the information as required is correct. I agree to comply with the information and sprinkler system Does a Sprinkler System Exist? Yes(i'1 No(' 1 working plans,to comply with all Town ordinances and state laws, and to build this structure according to the town's zoning and subdi- Work Class: vision codes,design review approval, National Fire Protection Asso- ciation 13, International Building and Residential Codes and other New( Addition(`' Remodel (-1 Repair( ordinances of Town plicable thereto. Retro-Fit(--. Other(7) X Type of Building: Co for Si ture(required) Single-Family( ) Duplex(n) Multi-Family( Commercial ( Restaurant((_. Other( i Property Information Parcel#: 210106302013 Complete Valuation for Fire Sprinkler Permit:45,950 (For parcel#,contact Eagle County Assessors Office at 970-328-8640 or Fire Sprinkler$: visit www.eaglecounty.us/patie) Tenant Name: Date Received: Owner Name: Town Of Vail 2014-0916 ii 4--,-0,,,0 ,:.. AFS Assurance Fire Systems FIRE SPRINKLER PRODUCT SUMITTALS & CALCULATIONS FOR Red Sandstone Garage 551 N Frontage Road W Vail, CO 81621 r :303-798-4448 o :720-922-7698 10864 West Coco Place 40 :info@assurancefiresystems.com Littleton,CO 80127 :www.assurancefiresystems.com +� Hydraulic Overview JobNumber:1 Resort Descrietion:Ordinar Grou•I ONE-PARKING Job Number Design Engineer 1 AL BRUCH Job Name: Phone FAX RED SANDSTONE GARAGE Address 1 State Certification/License Number 551 N.FRONTAGE RD.W Address 2 AHJ VAIL,CO Address 3 Job Site/Building System s Density Area of Application 0.150gpm/ft2 1950.00ft2(Actual 2015.66ft2) Most Demanding Sprinkler Data Hose Streams 5.6 K-Factor 17.55 at 9.822 250.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 117.00ft2 18 System Pressure Demand System Flow Demand 45.923 354.68 Total Demand Pressure Result 604.68 @ 45.923 +43.926(48.9%) Supplies Mr Check Point Gauges Node Name Flow(gpm) Hose Flow(gpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(qpm) 12 Water Supply 1678.00 250.00 90.000 89.000 ALAN W. BRUCH NICET LEVEL III WATER BASED SYSTEMS CERTIFICATION NO. 108440 EXPIRESJUNE 2021 JUNE 26, 2018 efhoff iffe..1ALCZ4a.- SIGNATURE Red Sandstone Garage alli Water Supply at Node 12(1678.00, 0.00,90.000,89.000) . : `1111111111 I Ill I Illl`l-1 100 : UN liii111111IJI1 e Static Pressure 90.000 90�.. —11678.00 @ 89.000 80 s' : i1111 fra. INT „11111111l11PII. . 70 • e '._ d--1.4. ,.,_. f . c_.. 60 ;M. . . .) : ..... �11111 p;;• 11111111 g 50 354.68 ri 45.923 I I I :,,i..ii 1111111111 a 40 E 604.68 with hose streams F,11.lltil 30 E System demand curve �� Y�`��U�.:aU�{II 20 10 IrlaA alIIIIIIIIIIIIIIIINI1111111IIIIIIIIIII1IIIIII II1IIIIII 111111111 III1I111I 111111 III 0 Z0p 1400 210028003500 U 1050175024503150 Water flow,gpm L©M.E.P.CAD,Inc. in AutoSPRINK®12 v12.0.59.0 6/26/2018 10:57:33PM Page 1 Hydraulic Graph Job Number:1 Report Description:Ordinary Group I(ONE-PARKING) Water Supply at Node 12 100 Static Pressure 90.000 90 _ 678.00 @ 89.000 80 70 60 Ul Q 50 N 354.68 @ 45.923 o_ 604.68 with hose streams 40 30 System demand curve 20 I, 10 0 MIB I_I I I I I I I I I I I I I I I I I I 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 111111111 111111111 111111111 111111111 111111111 0350 700 1050 1400 1750 2100 2450 2800 3150 3500 Water flow,gpm Hydraulic Graph Water Supply at Node 12 Static:Pressure 90.000 Residual:Pressure 89.000 @ 1678.00 Available Pressure at Time of Test 89.849 @ 604.68 system Dam and 45.923 @ 354.68 System Demand(Including Hose Allowance at Source) 45.923 @ 604.68 �4 ©M.E.P.CAD,Inc. AutoSPRINK®12 v12.0.59.0 6/26/2018 10:57:36PM Page 2 i Summary Of Outflowing Devices Job Number:1 g:::-..' - Report Description:Ordinary Group I(ONE-PARKING) Actual Flow Minimum Flow K-Factor Pressure Device (qpm) (qpm) (K) (psi) 4> Sprinkler 101 17.55 17.55 5.6 9.822 Sprinkler 102 17.89 17.55 5.6 10.205 Sprinkler 103 19.11 17.55 5.6 11.642 Sprinkler 104 17.55 17.55 5.6 9.824 Sprinkler 105 17.89 17.55 5.6 10.211 Sprinkler 106 19.12 17.55 5.6 11.655 Sprinkler 107 18.68 17.55 5.6 11.129 Sprinkler 108 18.95 17.55 5.6 11.455 Sprinkler 109 19.93 17.55 5.6 12.662 Sprinkler 110 18.77 17.55 5.6 11.233 Sprinkler 111 19.04 17.55 5.6 11.563 Sprinkler 112 20.02 17.55 5.6 12.783 Sprinkler 113 20.87 17.55 5.6 13.888 Sprinkler 114 20.88 17.55 5.6 13.909 Sprinkler 115 21.20 17.55 5.6 14.327 Sprinkler 116 21.29 17.55 5.6 14.455 Sprinkler 117 22.75 17.55 5.6 16.505 Sprinkler 118 23.18 17.55 5.6 17.140 b Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. In AutoSPRINK®12 v12.0.59.0 6/26/2018 10:57:39PM Page 3 '_ 1Node Analysis JobNumber:1 Report Description:Ordinary Group I(ONE-PARKING) Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 12 8193'-5 S 45.923 354.68 101 8220'-4% Spr(-9.822) 9.822 17.55 102 8220'-5 Spr(-10.205) 10.205 17.89 103 8220'-5'% Spr(-11.642) 11.642 19.11 104 8220'-4% Spr(-9.824) 9.824 17.55 105 8220'-5 Spr(-10.211) 10.211 17.89 106 8220'-5'/4 Spr(-11.655) 11.655 19.12 107 8220'-4'% Spr(-11.129) 11.129 18.68 108 8220'-4% Spr(-11.455) 11.455 18.95 109 8220'-5 Spr(-12.662) 12.662 19.93 110 8220'-4'/z Spr(-11.233) 11.233 18.77 111 8220'-4% Spr(-11.563) 11.563 19.04 112 8220'-4% Spr(-12.783) 12.783 20.02 113 8220'-11 Spr(-13.888) 13.888 20.87 114 8220'-10% Spr(-13.909) 13.909 20.88 115 8220'-10% Spr(-14.327) 14.327 21.20 116 8220'-10% Spr(-14.455) 14.455 21.29 117 8220'-10% Spr(-16.505) 16.505 22.75 118 8220'-4% Spr(-17.140) 17.140 23.18 1 8220'-5% P0(5'-0) 14.850 2 8220'-5% P0(5'-3%) 18.139 3 8220'-5'% PO(5'-3%) 18.168 4 8220'-5'/, P0(6'-0) 18.252 5 8220'-5 P0(6'-0) 18.423 6 8220'-4% P0(6'-0) 18.713 7 8212'-9 fE(9'-4%) 31.680 8 8208'-31/4 fE(13'-2) 36.160 9 8205'-11% DPV(7'-6%) 38.388 10 8203'-11 P0(26'-4) 40.513 11 8209'-2%< E(17'-7%) 38.650 13 8220'-4% P0(5'-3'/z) 9.833 14 8220'-4'% P0(5'-0) 9.833 15 8220'-5'% P0(5'-0) 14.872 16 8220'-5'% P0(5'-0) 15.322 17 8220'-5 P0(5'-0) 15.467 18 8220'-4% P0(5'-0) 17.633 L©M.E.P.CAD,Inc. 15 AutoSPRINK®12 v12.0.59.0 6/26/2018 10:57:42PM Page 4 Job Number:1 i ydraulic Analysis Report Description:Ordinary Group I(ONE-PARKING) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OF Route 1 BL 1.4420 17.53 3.44 100 0.030321 13'-0 Pf 0.394 101 8220'-4% 17.55 5.6 9.822 Sprinkler Pe -0.011 102 8220'-5 10.205 13'-0 Pv BL 1.4420 35.41 6.96 100 0.111418 13'-0 Pf 1.448 102 8220'-5 17.89 5.6 10.205 Sprinkler Pe -0.011 103 8220'-51h 11.642 13'-0 Pv BL 1.4420 54.52 10.71 100 0.247533 13'-0 Pf 3.218 103 8220'-5% 19.11 5.6 11.642 Sprinkler Pe -0.011 1 8220'-5% 14.850 13'-0 Pv BL 1.4420 75.39 14.81 100 0.450836 2'-0 Pf 3.291 1 8220'-5% 20.87 14.850 Flow(q)from Route 5 5'-3% Pe -0.002 2 8220'-5% 18.139 P0(5'-3%) 7-3''/ Pv CM 4.2600 75.39 1.70 100 0.002307 9'-0 Pf 0.021 2 8220'-5% 18.139 Pe 0.008 3 8220'-5'h 18.168 9'-0 Pv CM 4.2600 150.87 3.40 100 0.008323 9'-0 Pf 0.075 3 8220'-5% 75.47 18.168 Flow(q)from Route 2 Pe 0.008 4 8220'-51h 18.252 9'-0 Pv CM 4.2600 229.62 5.17 100 0.018105 9'-0 Pf 0.163 4 8220'-514 78.76 18.252 Flow(q)from Route 3 Pe 0.008 5 8220'-5 18.423 9'-0 Pv CM 4.2600 308.75 6.95 100 0.031310 9'-0 Pf 0.282 5 8220'-5 79.12 18.423 Flow(q)from Route Pe 0.008 6 8220'-4% 18.713 9'-0 Pv CM 4.2600 354.68 7.98 100 0.040469 191'-7 Pf 9.652 6 8220'-4% 45.93 18.713 Flow(q)from Route 9 46-11% Pe 3.315 7 8212'-9 31.680 4f E(9'-4%),E(9'-4%) 238'-6% Pv CM 4.2600 354.68 7.98 120 0.028882 21'-111h Pf 2.535 7 8212'-9 31.680 65'-10 Pe 1.945 8 8208'-3% 36.160 5fE(13'-2) 87'-9'% Pv CM 4.2600 354.68 7.98 100 0.040469 4'-3'% Pf 1.237 8 8208'-3% 36.160 26-3% Pe 0.991 9 8205'-11% 38.388 fT(18'-9%),DPV(7'-6%) 30'-7 Pv DY 4.2600 354.68 7.98 120 0.028882 0'-6 Pf 1.231 9 8205'-11% 38.388 42'-1% Pe 0.894 10 8203'-11 40.513 BV(15'-9%),P0(26'-4) 42'-7% Pv CM 6.3570 354.68 3.59 120 0.004112 12'-9 Pf 0.420 10 8203'-11 40.513 89'-3% Pe -2.283 11 8209'-2'% 38.650 2f E(17.-7%),2BV(12'-7),PRV, 102'-0'% Pv LtE(11'-3%),E(17-7%) UG 6.2800 354.68 3.67 140 0.003281 89'-4'% Pf 0.438 11 8209'-2'% 38.650 44'-1% Pe 6.835 12 8193'-5 45.923 2E(22'-0%),S 133'-6 Pv 250.00 Hose AllowanceAt Source 12 604.68 OF Route 2 BL 1.4420 0.02 0.00 100 0.000000 14'-0 Pf 0.000 101 8220'-4% 17.55 5.6 9.822 Sprinkler, 5'-3% Pe 0.012 13 8220'-4%z 9.833 P0(5'-3'%) 19'-3'% Pv BL 1.0490 0.02 0.01 120 0.000001 36-1 Pf 0.000 13 8220'-4'% 9.833 30'-0 Pe 0.000 14 8220'-4'% 9.833 10E(2'-0),2BaIV,T(5'-0), 66-1 Pv P0(5'-0) BL 1.4420 0.02 0.00 100 0.000000 14'-0 Pf 0.000 14 8220'-4'% 9.833 Pe -0.010 104 8220'-4% 9.824 14'-0 Pv BL 1.4420 17.58 3.45 100 0.030488 13'-0 Pf 0.396 104 8220'-4% 17.55 5.6 9.824 Sprinkler Pe -0.009 105 8220'-5 10.211 13'-0 Pv BL 1.4420 35.47 6.97 100 0.111753 13'-0 Pf 1.453 105 8220'-5 17.89 5.6 10.211 Sprinkler Pe -0.009 106 8220'-5% 11.655 13'-0 Pv BL 1.4420 54.59 10.72 100 0.248104 13'-0 Pf 3.226 106 8220'-5% 19.12 5.6 11.655 Sprinkler Pe -0.009 15 8220'-5'% 14.872 13'-0 Pv BL 1.4420 75.47 14.83 100 0.451762 2'-0 Pf 3.298 15 8220'-5% 20.88 14.872 Flow(q)from Route 6 5'-3% Pe -0.001 3 8220'-5'% 18.168 P0(5'-3%) 7-3% Pv Route 3 ©M.E.P.CAD,Inc. NU AutoSPRINK®12 v12.0.59.0 6/26/2018 10:57:45PM Page 5 Job Number:1 iii ydraulic Analysis Report Description:Ordinary Group I(ONE-PARKING) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length BL 1.5300 18.68 3.26 100 0.025576 13'-0 Pf 0.332 107 8220'-4'/2 18.68 5.6 11.129 Sprinkler Pe -0.007 108 8220'-4% 11.455 13'-0 Pv BL 1.5300 37.64 6.57 100 0.093442 13'-0 Pf 1.215 108 8220'-4% 18.95 5.6 11.455 Sprinkler Pe -0.007 109 8220'-5 12.662 13'-0 Pv BL 1.5300 57.56 10.04 100 0.205092 13'-0 Pf 2.666 109 8220'-5 19.93 5.6 12.662 Sprinkler Pe -0.007 16 8220'-5'/< 15.322 13'-0 Pv BL 1.5300 78.76 13.74 100 0.366307 2'-0 Pf 2.931 16 8220'-5'/< 21.20 15.322 Flow(q)from Route 7 6'-0 Pe -0.001 4 8220'-5% 18.252 P0(6'-0) 8'-0 Pv Route 4 BL 1.5300 18.77 3.28 100 0.025795 13'-0 Pf 0.335 110 8220'-4'% 18.77 5.6 11.233 Sprinkler Pe -0.005 111 8220'-4% 11.563 13'-0 Pv BL 1.5300 37.81 6.60 100 0.094249 13'-0 Pf 1.225 111 8220'-4% 19.04 5.6 11.563 Sprinkler Pe -0.005 112 8220'-4% 12.783 13'-0 Pv BL 1.5300 57.83 10.09 100 0.206876 13'-0 Pf 2.690 112 8220'-4% 20.02 5.6 12.783 Sprinkler Pe -0.005 17 8220'-5 15.467 13'-0 Pv BL 1.5300 79.12 13.81 100 0.369453 2'-0 Pf 2.956 17 8220'-5 21.29 15.467 Flow(q)from Route 8 6'-0 Pe -0.001 5 8220'-5 18.423 P0(6'-0) 8'-0 Pv Route 5 SP 1.0490 20.87 7.75 120 0.140786 0'-5'% Pf 0.767 113 8220'-11 20.87 5.6 13.888 Sprinkler, 5'-0 Pe 0.195 1 8220'-5% 14.850 P0(5'-0) 5'-5'%Pv OF Route 6 SP 1.0490 20.88 7.75 120 0.140982 0'-5%z Pf 0.768 114 8220'-10% 20.88 5.6 13.909 Sprinkler, 5'-0 Pe 0.195 15 8220'-5% 14.872 P0(5'-0) 5'-5'%Pv - Route 7 SP 1.0490 21.20 7.87 120 0.144897 0'-5'% Pf 0.792 115 8220'-10% 21.20 5.6 14.327 Sprinkler, 5'-0 Pe 0.203 16 8220'-5% 15.322 P0(5'-0) 5'-5'%Pv - Route 8 SP 1.0490 21.29 7.90 120 0.146099 0'-5% Pf 0.802 116 8220'-10% 21.29 5.6 14.455 Sprinkler, 5'-0 Pe 0.211 17 8220'-5 15.467 P0(5'-0) 5'-5%Pv Route 9 SP 1.0490 22.75 8.45 120 0.165161 0'-6 Pf 0.909 117 8220'-10% 22.75 5.6 16.505 Sprinkler, 5-0 Pe 0.219 18 8220'-4% 17.633 P0(5'-0) 5'-6 Pv BL 1.5300 45.93 8.02 100 0.135099 2'-0 Pf 1.081 18 8220'-4% 23.18 17.633 Flow(q)from Route 10 6'-0 Pe -0.000 6 8220'-4% 18.713 P0(6'-0) 8'-0 Pv Route 10 BL 1.5300 23.18 4.05 100 0.038133 13'-0 Pf 0.496 118 8220'-4% 23.18 5.6 17.140 Sprinkler Pe -0.003 18 8220'-4% 17.633 13'-0 Pv Equivalent Pipe Lengths of Valves and Fittings(C=120 only) II / Actual Inside Diameter \4 87 Value Of C 100 130 140 150 l Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 ©M.E.P.CAD,Inc. MU AutoSPRINK®12 v12.0.59.0 6/26/2018 10:57:45PM Page 6 Job Number:1 ydraulic Analysis Report Description:Ordinary Group I(ONE-PARKING) Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream (Total Length Pipe Type Legend Units Legend 11111M116 Fittings Legend d AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe E 90°Elbow Pe Pressure due to elevation difference between indicated points UG Underground Pv Velocity pressure at a point in a pipe EE 45°Elbow Eel 11W Elbow Ee2 22W Elbow Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. ,111 AutoSPRINK®12 v12.0.59.0 6/26/2018 10:57:45PM Page 7 June 28, 2013 Sprinkler5la MICROFAST°AND TECHNICAL DATA MicrofastHP° QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast°and MicrofastHP°Quick Response U prightand Conventional(Old • INO Style)Sprinklers are small,thermosensitive,glass-bulb spray sprinklers available in '" r-- sever al dif f er enffin is hes, -.severaldifferentfinishes,temperature ratings,and K-Factors to meet design require- ments.The special Polyester,Polytetrafluoroethylene(PTFE),and ElectrolessNickel PTFE(ENT)coatingscan be used in decorativeapplicationswherecolorsaredesired. In addition,these coatings have been investigated forinstallation in corrosive atmos- pheres and are listed/approved as corrosion resistant as indicated in the Approval Charts.(Note:FM Global approves the ENT coating as corrosion resistant. FM Global has no approval classificationforPTFE and Polyester coatings as corrosion resistant.) 2. LISTINGS AND APPROVALS Ous cULus Listed: Category VNIV FM FM Approved: Classes 2002 and 2020 NYC Approved: Calendar Number 219-76-SA and MEA 89-92-E,Volume 16 ABS Certified: Certificate 04-HS407984B-PDA [yds] VdS Approved: Certificates G4060054, G4060056, G4880046, G4930039, and G4980020 LPCB I LPC Approved: Ref.No. 096e/03,TE30401, and TE30872 (E CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, 0786-CPD-40171, and 0786-CPD-40278 0 MED Certified: Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to Approval Chart 1 and Design Criteria on pages 51c-d for cULus Listing requirements,and refer to Approval Chart 2 and Design Criteria on page 51e for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Viking Technical Data may be found on Available since 1987. The Viking Corporation's Web site at Minimum Operating Pressure: 7 psi (0.5 bar)* http://www.vikinggroupinc.com. Maximum Working Pressure: Sprinklers VK315 and VK340 are rated for The Web site may include a more recent use with water working pressures ranging from the minimum 7 psi (0.5 edition of this Technical Data Page. bar) up to 250 psi (17 bar) for high-pressure systems. High-pressure (HP)sprinklers can be identified by locating "250"stamped on the de- flector.All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing:U.S.A.Patent No. 4,831,870 Thread size: Refer to the Approval Charts Nominal K-Factor: Refer to the Approval Charts Glass-bulb fluid temperature rated to-65 °F (-55°C) Overall Length: Refer to the Approval Charts *cU Lus Listing, FM Approval, and NFPA 13 installs require a minimum of 7 psi (0.5 bar).The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). Material Standards: Frame Casting: Brass U NS-C84400 or QM Brass for Sprinklers 12978, 06766B, 07060, and 12281. Brass U NS-C84400 for all other sprinklers. Deflector: Brass UNS-C23000 or Copper U NS-C19500 for Sprinklers 12978, 06764B, and 12281. Copper U NS-C19500 for Sprinklers 06665B, 07060, and 14817. Brass U NS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass U NS-C36000 Bulb: Glass, nominal 3 mm diameter Form No. F_080488 Replaces page 51a-e, dated June 11, 2013. (ENT finish is no approved as corrosion resistant.) Sprinkler5lb June 28, 2013 Ni1uNG® MICROFAST°AND TECHNICAL DATA MicrofastHP° QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Belleville Spring Sealing Assembly:Nickel Alloy,coated on both sides with PTFE Tape Screw:Brass U NS-C36000 Pip Cap and Insert Assembly:Copper U NS-C11000 and Stainless Steel U NS-S30400 For PTFE Coated Sprinklers: Belleville Spring-Exposed,Screw-Nickel Plated, Pip Cap-PTFE Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed For ENT Coated Sprinklers: Belleville Spring-Exposed,Screw and Pipcap- ENT plated. Ordering Information: (Also refer to the current Viking price list.) Order Microfast°and MicrofastHP°Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass=A, Chrome= F,White Polyester= M-/W,Black Polyester= M-/B,and Black PTFE= N, ENT= JN Temperature Suffix(°F/°C): 135°/57° =A, 155°/68° = B, 175°/79° = D,200°/93° = E, and 286°/141° = G For example,sprinkler VK300 with a 1/2" thread,Brass finish and a 155 °F/68°C temperature rating= Part No. 12978AB Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"SprinklerAccessories"section of the Viking data book.) Sprinkler Wrench: Standard Wrench:Part No. 10896W/B (available since 2000) Sprinkler Cabinets: A. Six-head capacity: Part No. 01724A (available since 1971) B.Twelve-head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast°and MicrofastHP°Quick Response U prighland Conventional Sprinklers are available through a networkof domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGSAND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79°C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass,Chrome,White Polyester, Black Polyester, Black PTFE,and ENT Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black PTFE. ENT in all temperature ratings except 135 °F (57°C) Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51c-e.These tests cannot and do not represent all possible corrosive environments.Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment.For automatic sprinklers,the coatings indicated are applied to the exposed exteriorsurfaces only.Note that the spring is exposed on sprinklers with Polyester, ENT,and PTFE coatings. For ENT coated automatic sprinklers,the waterway is coated. June 28, 2013 Sprinkler5lc II(IF1G ® MICROFAST®AND TECHNICAL DATA MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 1 (UL) Temperature KEY Microfast®and MicrofastHP®Quick Response ,. Finis Neon(if applicable) Upright and Conventional Sprinklers Maximum 175 PSI (12 bar)WWP Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals3 SIN (Refer also to Design Criteria on page 51d.) Number' NPT BSP U.S. metric2 Inches mm cULus4 NYC8 VdS LPCB (E Upright-Standard Orifice 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 Al, 64 See Footnote 7. -- -- -- -- 07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 -- -- A2 A2 B212 B215 Conventional-Standard Orifice 067666 VK310 F1/2" 15 mm 5.6 80.6 2-3/16 56 A2 7 A2 -- A2 B212 B215 Upright-Large Orifice _ 06665B VK3503/4" -- 8.0 115.2 2-5/16 59 Al, 64 Al A2 A2 B212 -- _ 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 Al, 64 Al A2 A2 6212 -- _ 06764619 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 Al, 64 Al A2 -- A213 -- Conventional-Large Orifice 067686 VK354 3/4" 20 mm 8.0 115.2 2-5/16 59 Al A2 -- A2 6212 -- Upright-Small Orifice11 06717611 VK325 1/2" 15 mm 2.8 40.3 2-3/16 56 Al Al -- -- -- -- 067196" VK3271/2" 15 mm 4.2 57 2-3/16 56 Al Al -- -- -- -- _ 06931B11 VK327 -- 10 mm 4.2 57 2-3/16 56 -- -- A2 -- C314 -- Maximum 250 PSI(17 bar)WWP Upright-Standard Orifice Base Part Thread Size Nominal K-Factor Overall Length Listings and Approvals3 SIN (Refer also to Design Criteria on page 51d.) Number NPT BSP U.S. metric2 Inches mm cULus4 NYC8 VdS LPCB CE 0 12281 VK315 1/2" 15 mm 5.6 80.6 2-3/16 56 Al Al -- -- -- -- Upright-Small - Upright-Small Orifice 70 1228611 VK340 1/2" 15 mm 2.8 40.3 2-3/16 56 Al Al -- -- -- -- Approved Temperature Ratings Approved Finishes A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 1 Brass, Chrome, White Polyester56, Black Polyester", and 286°F (141°C) Black PTFE5 B- 155 °F (68°C), 175 °F (79°C),200 °F (93°C),and 286°F (141°C) 2-Brass,Chrome,White Polyester56,and Black Polyesters C 155 °F (68°C) 3-Brass and Chrome 4-ENT5 Footnotes I Base part number is shown.For complete part number,refer to Viking's current price schedule. 'Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. 5cU Lus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. 1 Meets New York City requirements,effective July 1,2008. 'Accepted for use,City of New York Board of Standards and Appeals,Calendar Number 219-76-SA. 9 Accepted for use,City of New York Department of Buildings,MEA 89-92-E,Vol.16. 10 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet systems only. Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. "The sprinkler orifice is bushed. 12 (E Certified,Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13 CE Certified,Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40278. 14 (E Certified,Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 15 0 MED Certified,Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. 19 The 1/2"NPT Large Orifice Sprinkler is Listed and Approved for retrofit only Sprinkler5ldJune 28, 2013 Ni1uNG® MICROFAST°AND TECHNICAL DATA MicrofastHP° QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA- UL (Also refer to Approval Chart 1 on page 51c) cULus Listing Requirements: Microfast®and MicrofastHP®Quick Response U prightand Conventional Sprinklers are cU Lus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers, or old style(conventional)sprinklers. • Designed for use in Light and Ordinary Hazard occupancies(exception:small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed.For conventional sprinklers, refer to the installation guidelines for old style(conventional)sprinklers. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB,APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Pr-CD l,eL l lve Wrench Sprinkler Flat Ca p M896 I' Figure 1: Standard Sprinkler Wrench 10896W/B June 28, 2013 Sprinkler5le MICROFASr AND TECHNICAL DATA MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) Temperature KEY Microfast®Quick Response Upright SprinklersEscutc �Finish A1Xf- heon(if applicable) Maximum 175 PSI(12 bar)WWP Base Part SIN Thread Size Nominal K-Factor Overall Length FM Approvals' Number' NPT BSP U.S. metric2 Inches mm (Refer also to Design Criteria below.) Standard Orifice 12978 VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 A2, B3 07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 A2 Large Orifice 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 A2, B3 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 A2, B3 06764B7 VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 A2, B3 Small Orifice4 0671766 VK325 1/2" 15 mm 2.8 40.3 2-3/16 56 Al Approved Finishes Approved Temperature Ratings 1 -Brass and Chrome A- 135 °F (57°C), 155 °F (68°C), 175 °F (79°C),200 °F (93°C),and 286 °F (141°C) 2 - Brass, Chrome, White Polyesters, and Black B- 155 °F (68 °C), 175 °F (79°C),200 °F (93°C),and 286 °F (141°C) Polyesters 3-ENT' Footnotes 1 Base part number is shown. For complete part number,refer to Viking's current price schedule. z Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the FM Approvals available at the time of printing.Check with the manufacturer for any additional approvals. FM Approved as quick response Non-Storage pendent sprinklers. For specific application and installation requirements,reference the latest appli- cable FM Loss Prevention Data Sheets(including Data Sheet 2-0). Other colors are available on request with the same Approvals as the standard colors. 6 The sprinkler orifice is bushed. 'The 1/2"NPT Large Orifice Sprinkler is Listed and Approved for retrofit only FM approved as corrosion resistant. DESIGN CRITERIA- FM (Also refer to Approval Chart2 above.) FM Approval Requirements: The sprinklers indicated in Approval Chart 2 are FM Approved as quick response Non-Storage upright sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(including Data Sheet 2-0). FM Global Loss Prevention Data Sheets contain guidelines relating to,but not limited to:minimum water supply requirements,hydraulic design,ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA,FM Global, LPCB, APSAD,VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_080488 Replaces page 51a-e, dated June 11, 2013. (ENT finish is no approved as corrosion resistant.) July 17, 2013 Sprinkler 105a C TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suitable for use in areas subject to freezing.The sprinklers are designed for dry sys- tem s and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation.They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklers are available in various finishes and tem perature ratings to meet design requirements.The special Polyester and Electroless Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are listed/approved as corrosion resistant as indicated in the Approval Charts.(Note:FM Global has no approval classification for Polyester coatings as corrosion resistant.) NOTE: When installed in some corrosive environments, the Polyester finish may change color.This natural discoloration over time is not in itself an indica- tion of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA25 on a more frequent basis. 2. LISTINGS AND APPROVALS cOos cULus Listed: Category VNIV .<>, FM Approved: Classes 2013 and 2015 —.o NYC Approved: MEA 89-92-E Volume 15 Refer to Approval Chart 1 and Design Criteria on page 105d for cULus Listing requirem ents,and refer to Approval Chart 2 and Design Criteria on page 105e for FM Approval requirem entsthat must be followed. 3. TECHNICAL DATA Specifications: Minimum Operating Pressure:7 psi (0.5 bar) Maximum Working Pressure:175 psi (12 bar). Factory tested pneumaticallyto 100 psi (6.89 bar) Thread size: 1" NPT or 25 m m BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*)for all listed and approved lengths. * Metric K-factor m easurem entshown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F (-55°C) Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Brass UNS-C26000 Bulb: Glass, nominal 3 m m diameter Belleville Spring Sealing Assembly:Nickel Alloy, coated on both sides with PTFE Tape Viking Technical Data may be found on Compression Screw:Brass UNS-C36000 The Viking Corporation's Web site at Pip Cap: Brass UNS-C31400 or UNS-C31600 http://www.vikinggroupinc.com. Pip Cap Adapter:Brass UNS-C36000 The Web site may include a more recent Orifice:Copper UNS-C22000 or UNS-C11000 edition of this Technical Data Page. Tube:ERW Hydraulic Steel Tube Support(Internal):Stainless Steel UNS-S30400 Barrel:Steel Pipe UNS-G10260, Electrodeposited Epoxy Base finish Barrel End and Threads:QM Brass Sleeve (for Adjustable Standard style only): Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons:Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons:Cold Rolled Steel UNS-G10080 Form No. F_031793 Replaces page 105a-f, dated October 25, 2010. (Added ENT finish.) Sprinkler 105b July 17, 2013 C TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email: techsvcs@vikingcorp.com ENT Coated Adjustable and Recessed Escutcheons:Stainless Steel UNS-S30400 Ordering Information: (Also refer to the current Viking price list.) Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish, the appropriate suffix for the temperature rating,and then the suffix for the length ("A"dimension)to sprinkler base part number.Order in a specific length noted as the "A"dimension.The "A"dimension is the distance from the face of the fitting(tee)to the desired finished surface of the ceiling. These sprinklers are listed and approved in lengths from 1-1/2"to 45-1/2"(38.1 m m to 1,156 m m)for the adjustable standard style, 3"to 47"(76.2 m mto 1,194 m m)forthe plain barrel style,and 3-1/4"to 47-1/2"(82.5 m m to 1,207 m m)for the adjustable recessed style. Lengths exceeding the standard lengths are available,with no approvals,on a"made-to-order"basis: Recessed Dry Pendent up to 65-1/2" (1,664 m m).Adjustable Standard Dry Pendent up to 63-1/2"(1,613 m m).Plain Barrel Dry Pendent up to 65" (1,651 m m). Contact the manufacturer for more information. Finish Suffix: Brass=A, Chrome= F,White Polyester= M-/W,and ENT= JN Temperature Suffix: 155 °F (68°C) = B, 175 °F (79 °C)= D, 200 °F (93 °C) = E, 286 °F (141 °C) = G For example,sprinkler VK176 with a Chrome finish and a 155 °F (68 °C) temperature rating, and "A" length of 10" = Part No. 08383UFB 10. Available Finishes And Temperature Ratings: Refer to Table 1. Wrench Accessories: (Also refer to the"Sprinkler Accessories"section of the Flat 111 Viking data book.) Protective 1. �i inns S rirkler Sprinkler Wrenches: Nournvism '"-I p A. Standard Wrench:Part No. 07297W/B(available since 1991) Shield B. Wrench for recessed sprinklers: Part No. 07565W/B** ® lil\�lyl (available since 1991) '`,` -' **A'/2"ratchet is required(not available from Viking). Sprinkler Guard: Chrome,with no listings or approvals,for installation on dry pendent sprinklers made after May 1994 only (Part No. 08954). Replacement Escutcheons: VIKING 07297 O A.Adjustable Standard Dry Escutcheon:Base Part No. 07741 B. Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Figure 1: Standard Sprinkler Wrench 07297WiB Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions,the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the waterway. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spraypattem to extinguish or control the fire. sprinkler wrench 07565W/Bw)K Must be 6. INSPECTIONS,TESTS& MAINTENANCE Used for installing recessed dr Refer to NFPA 25 for Inspection, Testing and sprinklers Maintenance requirements. Ali s s s of WM- i irnww ri 7. AVAILABILITY !lir II step 2 carefully press ilkI'll` /ill the wrench upward and The Viking Quick Response Dry Pendent Sprink- �` / turn slightly to ensure nip ler is available through a network of domestic — engagement with the - - and international distributors. See The Viking sprinkler wrench flats Corporation web site for the closest distributor Step 1: carefully AE*A 1/2" ratchet is k } } or contact The Viking Corporation. slide the wrench required (Not avail- sideways around the -= able from Viking) 8. GUARANTEE sprinkler deflector. For details of warranty, refer to Viking's current Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers July 17, 2013 Sprinkler 105c C TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLERTEMPERATURE RATINGSAND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 155 °F (68°C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass,Chrome,White Polyester, and ENT Corrosion-Resistant Coating3,4: White Polyester and ENT in all temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other lim its m ay apply,depending on fire loading, sprinkler location,and other requirem entsof the Authority Having Jurisdiction. Refer to specific installation standards. The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indicated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments. Note: These coatings are NOT cor- rosion proof.Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environ- ment. Polyester and ENT coatings are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 4 When installed in some corrosive environments,the Polyester finish may change color.This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA25 on a more frequent basis. For "A" Dimension: 1, Determine the distance from the face of the tee to the finished telling. 2. Round to the nearest 1/2" (12.7 mm) between 1-1/2" and 45-1/2" (38.1 mm and 1,156 mm). NOTE: The deflector will be located approximately 3-7/16" (87.3 mm) below the ceiling. with 1" (25.4 mm) upward and 1" (25.4 mm) downward adjustment. Deflector at minimum distance below ceiling. .00141MIN NOTE: To locate the deflector at the minimum distance below the ceiling, with ISI no downward adjustment Minimum ceiling opening ,—, -7/16" available, order the A (61.9 rim) dry pendent sprinkler diameter: 1-3/4" (44.5 mm). Minimum Maximum ceiling opening N, 1" (25.4 mm) shorter diameter: 2-1/4" (57 mm). than the "A" dimension, / IIIMr 13/16" 1�1 NOTE: Finished — (20.6 mm) 111111PP To locate the deflector Ceiling at the maximum distance 4-7/16" below the ceiling, with 1-1/2" Sleeve finish (1127 mm) no downward adjustment (38.1 mm) matches escutcheon. Maximum available, order the diameter _AL dry pendent sprinkler 3-1/16" I 1" (25.4 ma) longer (77.8 mm) than the "A" dimension, Deflector at maximum distance below ceiling. Figure 3: Adjustable Standard Dry Pendent Sprinkler Sprinkler 105d July 17, 2013 NIKING® TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email: techsvcs@vikingcorp.com 111111 Approval Chart 1 (UL) 1 Temperature KEY Quick Response Dry Pendent Sprinklers Finish F i Maximum 175 PSI (12 bar)WWP A1 Escutcheon(f appli Sprinkler Thread Size Nominal K-Factor2 Order Length Increment Listings and Approvals4 SIN Style _ (Refer also to Design Criteria below.) Base Part No.1 NPT BSP U.S. metric3 Inches mm cULuss NYCE VdS LPCB (E • 08383U Adjustable 1" -- 5.6 80.6 1/2" 12.7 Al,A5 Al -- -- -- -- VK176 16457U Standard -- 25 mm -- 80.6 1/2" 12.7 Al,A5 -- -- -- -- -- 08385U Adjustable 1" -- 5.6 80.6 1/4" 6.35 B2, B6 B2 -- -- -- -- 16453U VK180 Recessed -- 25 mm -- 80.6 1/4" 6.35 B2, B6 -- 08387U Plain 1" -- 5.6 80.6 1/2" 12.7 A3 A4 -- -- -- -- 16455U VK172 Barrel -- 25 mm -- 80.6 1/2" 12.7 A3 -- Approved Finishes and "A"Dimensions 1 -Chrom eor White Polyester'sprinklerwith a Chrom eor White Polyester Sleeve and Escutcheon Approved Temperature Ratings with"A"dimensions 1-1/2" to 45-1/2"(38.1 m m to 1,156 m m) A- 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), 2-Chrome or White Polyester'with"A"dimensions 3-1/4"to 47-1/2"(82.5 m m to 1,207 m m) and 286°F(141 °C) 3-Chrome,Brass,White Polyester',or ENT'with"A"dimensions 3"to 47"(76.2 m m to 1,194 m m) B - 155 °F (68 °C), 175 °F (79°C), and 200 °F 4-Chrom eor Brass with"A"dim ensions 3"to 47"(76.2 m m to 1,194 m m) (93°C) 5 - ENT' sprinkler with an ENT' Sleeve and Escutcheon with "A"dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) 6-ENT'with"A"dimensions 3-1/4"to 47-1/2"(82.5 m m to 1,207 m m) Footnotes ' Part num ber shown is the base part num ber.For com pletepart num ber,refer to current Viking price list schedule. 2 K-Factor applies for standard lengths("A"Dimensions indicated above). Metric K-factor m easurem entshown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. °This chart shows the listings and approvals available at the time of printing.Other approvals maybe in process.Check with the manufacturer for any additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S.and Canada. e Accepted for use, City of New York Departm entof Buildings, MEA Num ber 89-92-E,Vol.15. cULus Listed as corrosion resistant. DESIGN CRITERIA- UL Also refer to Approval Chart 1 above.)_ NOTE:When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklers are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. IMPORTANT: Always refer to Bulletin Form No. F_091699- Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data,the appropriate standards of NFPA,LPCB,APSAD,VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. July 17, 2013 Sprinkler 105e NIKINGC TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart 2 (FM) - Temperature KEY Quick Response Dry Pendent Sprinklers ��Finish Maximum 175 PSI(12 bar)WWP A1XFEscutcheon(if applicable) Sprinkler Base SIN Style Thread Size Nominal K-Factor2 Order Length Increment FM Approvals4 Part No. NPT BSP U.S. metric Inches mm (Refer also to Design Criteria below.) 08383U 1" -- 5.6 80.6 1/2" 12.7 Al 16457U VK176 Adjustable Standard -- 25 mm -- _ 80.6 1/2" 12.7 Al 08385U 1" -- 5.6 80.6 1/4" 6.35 B2 VK180 Adjustable Recessed 16453U -- 25 m m -- 80.6 1/4" 6.35 B2 08387U 1" -- 5.6 80.6 1/2" 12.7 A3 16455U VK172 Plain Barrel -- 25 mm -- 80.6 1/2" 12.7 A3 Approved Temperature Ratings Approved Finishes and"A"Dimensions A-155 °F(68°C), 175 °F(79°C),200°F(93°C), 1 - Brass,Chrome,White Polyester, or ENT'sprinkler with a Brass,Chrome,White Polyester, or and 286°F(141 °C) ENT'Sleeve and Escutcheon with"A"dimensions 1-1/2"to 45-1/2"(38.1 m m to 1,156 m m) 2-Brass,Chrome,White Polyester,or ENT'with"A"dimensions 3-1/4"to 47-1/2"(82.5 m mto 1,207 m n) B-155°F(68°C),175°F(79°C),and 200°F(93°C) 3-Brass,Chrom e,White Polyester,or ENT' with"A"dim ensions 3"to 47"(76.2 m m to 1,194 m m) Footnotes ' Part num ber shown is the base part num ber.For com pletepart num ber,refer to current Viking price list schedule. 2 K-Factor applies for standard lengths("A"Dimensions indicated above). 3 Metric K-Factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. °This chart shows the FM Approvals available at the time of printing. Other approvals may be in process.Check with the manufacturer for any ad- ditional approvals. 5 FM approved as corrosion resistant. DESIGN CRITERIA- FM (Also refer to Approval Chart 2 above.) NOTE:When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5012-S-BI tees.When selecting other CPVC fittings, contact Viking Technical Services. FM Approval Requirements: The Dry Pendent Sprinklers in the Approval Chart above are FM Approved as quick response Non-storage standard spray sprinklers as indicated in the FM Approval Guide. For specific application and installation requirements,reference the latest applicable FM Loss Prevention Data Sheets(includ- ing 2-0)and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not lim ited to: minimum water supply requirements,hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT:Always refer to Bulletin Form No. F 091699-Care and Handling of Sprinklers.Also refer to page DRY1-3 for general care, installation, and maintenance information.Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data,the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other similar organizations,and also with the provisions of governmental codes, ordinances,and standards,whenever applicable. 1'00 _ oon •o re_ Air i0. .„ 'i For "A" Dimension } 1 Determine the distance = from face of tee to For "A" Dimension, the finished ceiling. A2. Round to nearest 1/4° A 1. Determine the Minimum ceilingopening, (635 mm) between distance from P g'' \ Outside the face of the 2-1/8" (54 mm) diameter, 3-1/4" (82.5 mm) and 47-1/2" (1,207 mm), diameter, tee to the hose 1-5/16" , of the sprinkler. Maximum ceiling opening, (33.4 mm) 2-1/2" (63,5 mm) diameter, NOTE n Sprinkler will be 2. Roundup tothe recessed approximately same as nexxtthighestt 1/2' 5/16" (7.9 mm) above 1" (25 mm) (12.7 mm) incre- Schedule Hent between 3" the finished ceiling with 40 pipe). (76.2 mm) and Adjustment: 5/8" (15.8 mm) vertical 47" (1,194 mm). 5/16" (7.9 mm) C-_ 1-�1 adjustment available. 5/16" (7.9 mm) 1 . 1 �--i I Finished ceiling 1-5/8" Minimum, 1" (25,4 mm) ��sN�<� (48.3 mm) Maximum, 1-5/8" (42.1 mm) --I- --.-3-1/16" (77.9 mm)- Figure 4: Adjustable Recessed Dry Pendent Sprinkler L Figure 5: Plain Barrel Dry Pendent Sprinkler Sprinkler 105f July 17, 2013 Nimmict TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email: techsvcs@vikingcorp.com Ambient Exposed Barrel Install 1 inch NPT threaded Temperature Ambient Temperature / end of drypendent sprinkler Deflector at p 40°F/4°CI50°F/10°CI60°F/16°C P P minimum distance of Protected — into the 1 inch NPT outlet below ceiling Areaw at the Exposed Minimum Barrel of a malleable iron tee fitting Discharge End LengthEK Face of Tee gper ANSI B 16.3 (Class 150) of the Sprinkler to Top of Ceiling Up to 2' (50.8 mm) In (mm) In. (mm) In. (mm) _,. _ or cast iron threaded tee fitting 40°F (4°C) 0 1 0 0 j i per ANSI 16.4 (Class 125) only. adjustment available, 30°F (-1°C) 0 0 0 , ® 1333333 Note; 20°F ( 7 C) 4 (100) 0 0 Minimum ceiling opening diameter: To locate the 1-3/4" (44.5 mm) — deflector at the 10°F (-12°C) 8 (203) 1 (25.4) 0 (Exposed i 0°F (-18°C) 12 (305) 3 (76) 0 Barrel) Maximum ceiling opening diameter -7/16' minimum distance 2 1/4" (57 mm). i � below the ceiling, -10°F (-23°C)14 (356) 4 (102) 1 (25,4) (61,9 mm) with no upward -20°F (-29°C)14 (356) 6 (152) 3 (76) / Seal the clearance I Minimum adjustment avail -30°F (-34°C)16 (406)8 (203)4 (102) space around the ---'N'--- able, order the ® 333333 sprinkler to avoid leak- dry pendent sprink- -40°F (-40°C)18 (457)8 (203) 4 (102) P ler 1' (25.4 mm) -50°F (-46°C)20 (508)10 (254)6 (152) i gB333336 13333Ee of air into the �I�I= shorter than the -60°F (-51°C)20 (508)10 (254)6 (152) ® — 13/16" protected area and "A" dimension. C20,6 mm) consequent formation FFFFICF1 Ceiling - of condensate around the frame, which could Note; / Sleeve finish inhibit operation or To locate the 4-7/16"cause premature opera deflector at the 1-1/2" (38.1 mm) matches tion, Refer to Figure (112.7 mm) maximum distance diameter 21... escutcheon 7 below. below the ceiling, Maximum with no downward If humidity and temp- . . adjustment avail- 3-1/16' erature differential able, order the (Protected Area) causes condensation dry pendent sprink (77,8 mm) on the exposed dry �'' - ler 1' (25,4 mm) sprinkler, consider longer than the wrapping the exposed Deflector at "A" dimension. barrel with insulation, maximum distance foam insulating tape, below ceiling or equivalent. *The protected area refers to the area below the ceiling. The ambient temperature is the temperature at the discharge end of the sprinkler. For protected area temperatures that occur between the values listed, use the next cooler temperature. wwThe minimum required barrel length is not the same as the 'A' dimension. Refer to Figures 3-5 for the 'A' dimension. NOTE: Exposed minimum barrel lengths are inclusive up to 30 mph wind velocities. Figure 6: Dry Pendent Sprinkler Required Minimum Barrel Length Based on Ambient Temperature in the Protected Area (Adjustable Standard Dry Pendent Sprinkler is Shown) Seal Part No. 13864 ■ (or equivalent method) Seal IMIIM AB i In Clearance ® Insulated Opening ■ Ceiling ■ I. .I Dry Sprinkler Seal on the Dry Sprinkler Seal Within the Ceiling Exterior of the Ceiling Figure 7: Dry Sprinkler Seal (Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_031793 Replaces page 105a-f, dated October 25, 2010. (Added ENT Finish.) FireLock® ButerflyValve ✓ctaulic° Style 705 with Weatherproof Actuator 10.81 Material Specifications: Body: Ductile iron conforming to ASTM A-536, grade 65-45-12 End Face, 2 — 6"/50— 150 mm:Ductile iron conforming to ASTM A-536, grade 65-45-12 Seal Retainer,8 — 12'1200— 300 m m:Ductile iron conforming to ASTM A-536, grade 65-45-12 Approvals/Listings: Coating:B lack alkyd enamel c®us ® vds LPCB �? Disc: Ductile iron conforming to ASTM A-536, grade LISTED #G410001 104j/04 65-45-12, with electroless nickel coating conforming to See Victaulic Publication 10.01 for more details. ASTM B-733 Seat: Product Description: 0 Grade "E" EPDM The Series 705 B utterfly Valve features a weatherproof actuator housing Approved for indoor or outdoor use, a Stems:416 stainless steel conforming to ASTM A-582 ductile iron body and disc with EPDM seats. Designed for fire protection services only.Victaulic FireLock Stem Seal Cartridge: C36000 brass Series 705 Butterfly Valve is cULus Listed, LPCB Listed, FM and VdS Approved for 300 psi/2068 kPa service. Bearings: Stainless Steel with TFE lining Contact Victaulic for details of agency approvals. Stem Seals: EPDM Stem Retaining Ring:Carbon steel Actuator: 0 2—8"/50—200mm: Brass or bronze traveling nut on a steel lead screw, in a ductile iron housing ❑ 10— 12"/250—300mm: Steel worm and cast iron quadrant gear, in a cast iron housing Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date • victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. 1 ictaulic° victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Approvals and Listings: Approval/Listing Service Pressures Series 705 Butterfly Valve Size cULus FM Vds LPCB 2"/50 mm up to 300psi/2068kPa n/a up to 300psi/2068kPa i up to 300psi/2068kPa 21 1/2765 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 7 6.1 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3"/80mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 4"/100 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 5"/125 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 139.7 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 6"/150 mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 165.1 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 8"/200mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 10"/250 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 12"/300 mm up to 300psi/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 2 ictaulic" victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Dimensions: t / 0H m I ,\, ,H. __ � II i GE-; .. A ..-D NOTE:OPTIONAL l 715MM TAP AVAILABLE. CONTACT VICTAULIC FOR DETAILS. Actual Dimensions Nominal Outside E to E Size Diameter A B C D E F G DIA H J inches inches inches inches inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 2 2.37 5 4.25 2.28 6.41 _ - 4.00 4.22 4.50 2.12 60.3 60.3 108.0 57.9 162.8 101.6 107.2 114.3 53.8 21/2 2.87 5 3.7 7 2.28 7.54 _ _ 4.00 4.22 4.50 1.7 7 7 3 7 3.0 95.8 57.9 191.5 101.6 107.2 114.3 45.0 76.1mm 3.000 3.77 2.28 7.54 _ _ 4.00 4.22 4.50 1.77 7 6.1 95.8 57.9 191.5 101.6 107.2 114.3 45.0 3 3.500 3.7 7 2.53 7.7 9 _ - 4.50 4.22 4.50 1.7 7 88.9 88.9 95.8 64.3 197.9 114.3 107.2 114.3 45.0 4.250 4.63 2.88 8.81 _ _ 5.50 4.22 4.50 2.20 108 mm 108.0 117.6 73.2 223.8 139.7 107.2 114.3 55.9 4 4.500 4.63 2.88 8.81 _ _ 5.50 4.22 4.50 2.20 114.3 114.3 117.6 73.2 223.8 139.7 107.2 114.3 55.9 5.250 5.88 3.35 10.88 _ _ 6.56 6.19 6.30 2.58 133 mm 133.0 149.4 85.1 276.4 166.6 157.2 160.0 65.5 5.500 5.88 3.35 10.88 _ _ 6.56 6.19 6.30 2.58 139.7 mm 139.7 149.4 85.1 276.4 166.6 157.2 160.0 65.6 5 5.563 5.88 3.35 10.88 _ _ 6.56 6.19 6.30 2.58 141.3 141.3 149.4 85.1 27 6.4 166.6 157.2 160.0 65.5 159 mm 6.250 5.88 3.84 11.38 - 0.41 7.52 6.19 6.30 2.58 159.0 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6.500 5.88 3.84 11.38 _ 0.41 7.52 6.19 6.30 2.58 165.1mm 165.1 149.4 97.5 289.1 10.4 191.0 157.2 160.0 65.5 6 6.625 5.88 3.84 11.38 _ 0.41 7.52 6.19 6.30 1.90 168.3 168.3 149.4 97.5 289.1 10.4 191.0 157.2 160.0 48.3 8 8.625 5.33 5.07 13.53 0.80 1.47 10.00 6.19 8.10 2.33 219.1 219.1 135.4 128.8 343.6 20.3 37.3 254.0 157.2 205.7 59.2 10 10.7 50 6.40 6.37 15.64 1.41 1.81 12.25 8.10 9.00 _ 27 3 27 3.0 162.6 161.8 397.3 35.8 46.0 311.2 205.7 228.6 12 12.7 50 6.50 7.36 16.64 2.30 2.80 14.25 8.10 9.00 - 323.9 323.9 165.1 186.9 422.7 58.4 71.1 362.0 205.7 228.6 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 3 ictaulic" victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/ meters of straight pipe. Nominal Outside Equivalent Size Diameter mm mm Feet/m inches inches of pipe 2 2.375 6 50 60.3 1.8 21 2.875 6 65 73.0 1.8 76.1 mm 3.000 6 76.1 1.8 3 3.500 7 80 88.9 2.1 4 4.500 8 100 114.3 2.4 • 108 mm 108 mm 8 2.4 • 5 5.563 12 125 141.3 3.7 133 mm 133 mm 12 3.7 139.7 mm 5.500 12 139.7 3.7 6 6.625 14 150 168.3 4.2 159 mm 159 mm 14 4.3 165.1 mm 6.500 14 165.1 4.2 8 8.625 16 200 219.1 4.9 10 10.750 18 250 273.0 5.5 12 12.750 19 300 323.9 5.8 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 4 ictaulicc victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Performance: Cv values for flow of water at +60°F/+16°C through a fully open valve are shown in the table below. For additional details, contact Victaulic. Formulas for Cv values Formulas for Kv values AP=Q2/C 2 Where: AP=Q2/Kv2 Where: v Flow Coefficient CC Flow Factor K Q=C x VAP Q=KvxVAP Q(Flow) GPM Q(Flow) m3/h r 4P(Pressure Drop) psi AP(Pressure) bar Valve Size Full Open Valve Size Full Open Actual Actual Nominal Outside Nominal Outside Size Diameter Flow Coefficient Size Diameter Flow Coefficient inches inches Cv inches inches K mm mm mm mm 2 2.375 2 2.375 50 60.3 17 0 50 60.3 147 21/2 2.875 260 21/2 2.875 225 65 7 3.0 65 7 3.0 76.1mm 7600 260 76.1 .1mm 7600 225 .1 3 3.500 3 3.500 80 88.9 440 80 88.9 380 4 4.500 4 4.500 100 114.3 820 100 114.3 710 108 mm 108 mm 820 108 mm 108 mm 710 5 5.563 5 5.563 125 141.3 1200 125 141.3 1040 133 mm 133 mm 1200 133 mm 133 mm 1040 139.7 mm 139 1200 1397 .7 mm 139.71040 6 6.625 6 6.625 150 168.3 1800 150 168.3 1560 159 mm 159 mm 1800 159 mm 159 mm 1560 0 .500 165.1 mm 665 1800 165.1 mm 665 1560 8 8.625 8 8.625 200 219.1 3400 200 219.1 2940 10 10.7 50 10 10.7 50 250 273.0 5800 250 273.0 5020 12 12.7 50 12 12.750 300 323.9 9000 300 323.9 7 7 90 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 5 ictaulic" victaulic.com I Butterfly Valve I Series 705 I Publication 10.81 Switch and Wiring: DL LISTED JUNCTION BOX//7 CONDUIT SA/ 1. The supervisory switch contains two single pole, �, '-1. ►��«.IIII:� double throw, pre-wired switches. �'� �� r NPT 1®1 CONDUHCONNECTORS �% 2. Switches are rated: > WIRE NUTS 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps @ 125 VDC FIREALARM TO END-OF-LINE RESISTOR, CONTOL 0.25 amps © 250 VDC SUPE VP""" DR"EXT'"°"ATDR SUPERVISORY CIRCUIT NO. COM. 3. Switches supervise the valve in the "OPEN" position. SWITCH -. CONTACTRATING: nj M M 10A AT 125 AND 5. One switch has two#18 insulated wires per terminal, 250VAC, lll� lll� lll� 0.5 AAT 125 VDC, which permit complete supervision of leads (refer 0.25AT250VDC REEL ' _ OR to diagrams and notes below).The second switch VOLTAGE SOURCE HORN has one #18 insulated wire per terminal. This double Switch 1:2 leads per terminal Switch 2:1 lead per terminal circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm, in the area that the valve NOTE: The above diagram shows a connection between is installed. the common terminal (yellow—S1 and yellow-with- orange stripe—S2) and the normally closed terminal 6. A#14 insulated ground lead (green) is provided. (blue—S1 and blue-with-orange stripe—S2). In this Switch #1 = S1 example, the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open,the For connection to the supervisory circuit of a UL indicator light and alarm will go out. Cap off any unused Listed alarm control panel wires(e.g. brown with orange stripe). Switch #2 = S2 Only S1 (two leads per terminal) may be connected to Auxiliary switch that may be connected to auxiliary the fire alarm control panel. devices, per the authority having jurisdiction The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per Normally Closed: (2) Blue NFPA70 (NEC). sl Common: (2) Yellow Normally Closed: Blue with Orange Stripe s2 Normally Open: Brown with Orange Stripe Common: Yellow with Orange Stripe Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product youare installing. Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic®is a registered trademark of Victaulic Company. 10.81 5662 Rev F Updated 11/2014 ©2014 Victaulic Company.All rights reserved. victaulic.com 6 jctaulic° Bulletin 358 Rev. C ModeEXLowPressure Reliabl Q D ryP ipeValve System 5 2" (DN50), 21/2"(DN65), 3" (DN80), 76 mm, 4" (DN100 ), 6" (DN150), 165mm&8"(DN200) Features 1. Differential latching clapper-type, lightweight, dependable construc- tion. 2. Low Air Pressurized System, 8 psi -to-28 psi (0.6 bar-to- 1.9 bar) Max 0' o. - 11) 3. Reset externally. Cover removal is eie '�'� o a® not required. 4. No priming water requirement 5. Hydrostatic testing with the clapper 'jnoodaVN• ��litaerh‘ in the closed positions ���yu"�'� Ant I �..� 6. No riser check valve required i, �� ����� I ,�� 7. Valve latches in open position. No ( ,r r. / 1 pressure-operated relief valve is -”;-4,t,V 6 117-- 1-1T641110INCH Ise required \ ,ir�r ,; , ��� ��11i 8. Nitrogenpressurized systemoptional .; � � �����E 1, 41, 9. Drainvalvetodrainpotentialstanding _OAiff water column. ` :,*��_ 10. Grooved inlet and outlet. % ���. ��G3 *TEN=�i� 11. Pressure rating of 250 psi (17.2 bar) ���1� or 300 psi (20.7 bar) [(4" (100mm), 6" (150mm) & 165mm only)]. Note: For retrofit applications where an existing pneumatic supply is available.The Reli- able Model EX Dry Valve can be oper- � I) �` /,l ated with 40 psi (2.8 bar) maximum air � �_ or nitrogen pressure. The higher pres- j► sure may result in a delay in valve op- eration and longer water delivery time 358CVRD when compared to the lower (design) pressures of the valve. Listings & Approvals (Only when used with Reliable's Trim Sets.) 1. Listed by Underwriters Laboratories, Inc. and UL certified for Canada (cULus). 2. Certified by Factory Mutual Approvals(FM). 3. Loss Prevention Certification Board(LPCB) 4. VdS Schadenverhutung GmbH (VdS) (DN50, DN65, DN80, DN100, DN150, and DN200 sizes only). 5. EN Certificates(CE) per EN 12259-3:2000 + A1:2001 + A2:2005 DN50: 0786-CPR-40300 DN65: 0786-CPR-40301 DN80:0786-CPR-40302 DN100: 0786-CPR-40303 D N 150: 0786-CPR-40304 DN200: 0786-CPR-40305 Reliable Automatic Sprinkler Co., Inc., 103 Fairview Park Drive, Elmsford, New York 10523 SECTION VIEW OFMODEL"CLOSED" DRY VALVE WITH CLAPPER IN OPEN , CLOSED AND REAR VIEW OF "LATCHED" POSITIONS MODEL EX DRY VALVE TO SYSTEM LEVER SYSTEM SIDE SUPERVISORY11\ :11111. GAS PORTCLAPPER IN �OPEN POSITION PUSH ROD �, 40 � lociSUPPLEMENTAL tI SYSTEM SIDE PORT 1/ CLAPPER IN l.��J` �1 (NOT USED) yO - �� o� "LATCHED"POSITION Ilk �(fi kw, r..., /p 1/ CLAPPER IN •'r4illi i®o ®/i�/ �c �.N �I`�M li � ` "CLOSED"POSITION . /��� "ACTUATOR ��� 1 C � ry�� ALARM PORT ` / 1 `�11SUPERVISORY GAS ��l� ����� ` � ��� ��PORT I��;� iCONDENSATE � ��� ACTUATORIPUSH ROD •.I1- DRAIN PORT CHAMBER ACTUATOR r � TEST PORT 1DRAIN PORT : \ ) ` EXTERNALPUSH ROD CHAMBER + RESET KNOB m. ii. �; WATER PORT SUPPLY SIDE , ` SYSTEM DRAIN PORT WATER PORT SYSTEM DRAIN PORT PUSH INWARD AND ROTATE EXTERNAL RESET KNOB CLOCKWISE TO RESET CLAPPER. DO SO ONLY WHEN PUSH ROD CHAMBER IS UNPRESSURIZED(0 PSIG). FROM 359FG01B SUPPLY Fig. 1 General The Reliable Model EX Low Pressure Dry Pipe Valve is When a sprinkler operates,there will be a loss of air or a hydraulically operated,differential latching clapper-type nitrogen pressure in the sprinkler system's piping which valve(see Fig 1.) designed for use as a primary control will cause the Model EX Low Pressure Dry Valve to open. valve in a dry pipe valve system. The trim set used with The loss of air pressure allows a releasing discharge of the Model EX Low Pressure Dry Pipe Valve allows the sys- water from the pushrod chamber. Since the pressure can- tern's air or nitrogen pressure requirement to be consider- not be replenished through the inlet restriction as rapidly ably less than the available water supply pressure(See as it is vented, the push rod chamber pressure falls in- Table A, page 7). The following benefits are a direct result stantaneously. When the push rod chamber pressure ap- of the ability to use lower air pressure: proaches approximately one-third of the supply pressure, 1. In refrigerated area systems,lower air pressure de- the upward force of the supply pressure acting beneath creasesthe possibilityof ice plugs,which could im- the clapper overcomes the lever-applied force thereby pede or prevent the flow of water to sprinkler heads opening the clapper. in the event of fire. Once the clapper has opened,the lever acts as a latch, 2. Lower air pressure (volume)will enable smaller ca- preventing the clapper from returning to the closed po- pacity, lower cost dehydration equipment when it is sition. Water from the supply flows through the Dry Pipe required. Valve into the system piping.Water also flows through the 3. Lowerair or nitrogen pressure can reduce water de- Dry Pipe Valve's alarm outlet to the alarm devices. livery time when the system actuates,and in some After system shutdown, resetting the Model EX Low cases,may eliminate the need for an accelerator. Pressure Dry Pipe Valve is quite simple. Doing so only re- 4. Low pressure requirements make the use of dry ni- quires pushing in and turning the reset knob at the rear trogen gas, instead of air,practical even on larger of the valve(see Fig. 1). The external reset feature of the systems.Resulting benefits include a lower-than-air Model EX Low Pressure Dry Pipe Valve provides a means dew point,which minimizes ice plugging of system for simple, economical system testing, which is one es- lines, and enhances "user friendliness" during in- sential facet of a good maintenance program.The external stallation and operation. reset feature does not, however, eliminate another impor- 5. System maintenance is simplified since priming tantfacetofgoodmaintenance,namely,periodiccleaning water is not required and the Dry Pipe Valve can be and inspection of the internal valve parts. reset externally without cover removal.This is ac- In the event that water builds up inside the valve due to complished by pushing in and turning the external condensate from the air supply system or water left inside reset knob at the rear of the Dry Pipe Valve(see from valve system testing,a drain is available for venting. Fig.1). This feature provides a significant system- After closing the main supply valve,a small valve over the restoration time advantage. drain cup can be opened slightly until the water inside the The Model EX Low Pressure Dry Pipe Valve's trim set(see valve body and the main pipe column has drained. Fig.2)provides all of the necessary equipment for connec- The Model B Manual Emergency Station is also included tions to the pushrod chamber's inlet and outlet ports,the in the Model EX Low Pressure Dry Pipe Valve trim set. It 11/4" (30mm) or 2" (50mm) main drain, alarm devices, air consists of an aluminum nameplate mechanically at- supply, water supply and required pressure gauges. This tached to a ball valve.The valve handle in its OFF position trim set is available in individual parts, in time-saving,seg- is guarded against accidental turning to the ON position mentally assembled kit forms, or fully assembled to the (and system discharge)by a nylon cable tie provided with Model EX Low Pressure Dry Pipe Valve(with or without a each trim kit. The cable tie is inserted after the system control valve). has been restored for operation. The nylon cable tie is de- All the sizes of the Model EX Low Pressure Dry Pipe signed to allow,in case of an emergency, forceful turning Valvetrim sets maybe equipped with the optional Reliable of the valve handle to the ON position. As an alternative Model B1 Accelerator, trim kit P/N 6516000003,(see Figs. to the Model B Hydraulic Manual Emergency Station,the 2&3).This device acts as an exhauster which will hasten Model A Hydraulic Manual Emergency Pull Box(see Reli- the operation of the Model EX Low Pressure Dry Valveand able Bulletin 506) is also available and can be provided minimize the water delivery time for the entire system. as an option. Whenever ambient temperature conditions are high, the System Operation water temperature in the Model EX Low Pressure Dry Pipe The Reliable Model EX Low Pressure Dry Pipe Valve is Valve's pushrodchambercould possibly increase,thereby shown in both closed and open positions in Fig. 1. In the increasing the pressure in the chamber to values exceed- closed position,the supply pressure acts on the underside ing the rated pressure of the system. In an indoor installa- of the clapper and also on the push rod through the push tion where standard room temperatures are exceeded, a rod chamber's inlet restriction. The resultant force due to pressure relief kit may be needed. Pressure relief kit, P/N the supply pressure acting on the push rod is multiplied by 6503050001, can be installed into the pushrod chamber's the mechanical advantage of the lever and is more than releasing line to limit the pressure to 250 psi(17.2 bar). sufficient to hold the clapper closed against normal sup- ply pressure surges. 3. LOW AIR PRESSURE SWITCH (NOT INCLUDED WITH / LOOSE AND SEGMENTALLY ASSEMBLED) iO (�4 ri��1��� /�---- ;''/ FROM AIR OR Il'^i` �� / ——— K.-if'NITROGEN SUPPLY O (�i4F� / tQ�. / Ll/ PRESSUREAIM O�•-.H / / RELIEF // ,•-'ij f VALVE ` _ 111111 0 c1T(f: ‘,..s•rink, ( .� 111 TO ��� ALARM PRESSURE SWITCH :��iyf DRAIN (NOT INCLUDED WITH J 'I I LOOSE AND SEGMENTALLY ASSEMBLED) I nl I VENT TO ATMOSPHERE TO 0 MODEL EX SYSTEMA OPTIONAL DRY PIPE -T p6•1' I.'/, PUSH-ROD CHAMBER VALVE 611,1- MODEL BI Or I �_/ TOMECHANICAL ACCELERATOR KR PRESSURE GAUGE f� SPRINKLERA ARM (PART NUMBER 6616000013) `���� / �l � J /I I q'\ 1 •..z.-:----. /// TO NON-SILENCEABLE {I -�, / /I (1.5- I-- `r L 1 ' ` ALARM PRESSURE SWITCH V //r I w05.0; / (REF.NEPA 72) 1 60 `*1 I`tt...,49,"0 lir r__ ,�_4 1.( J �. u 11 TO ":1711'zo BAR l'� — 'tel(r V _C IEJ.I BUP �� L— .St,q, �c I Bili•*I' 4J AVAILABLE TRIM CONFIGURATIONS: 0 1)INDIVIDUAL PARTS(MODEL EX DRY PIPE VALVE SOLD SEPARATELY) TO Ii 2)SEGMENTALLY ASSEMBLED(MODEL EX DRY PIPE VALVE SOLD SEPARATELY) DRIP 0 •3)FULLY ASSEMBLED TO MODEL EX DRY PIPE VALVE WITH CONTROL VALVE CUP V Ij� �A` WATER SUPPLY ( 4)FULLY ASSEMBLED TO MODEL EX DRY PIPE VALVE WITH CONTROL VALVE W/INLET SPOOL i�. PflessuEGAucE 5)FULLY ASSEMBLED TO MODEL EX DRY PIPE VALVE WITHOUT CONTROL VALVE -— THE MODEL EX DRY PIPE VALVE DOES NOT REQUIRE Fig AN IN-LINE CHECK VALVE FOR AIR MAINTENANCE.THE ALL STEEL COMPONENTS OF THE TRIM ASSEMBLIES ARE GALVANIZED � RECOMMENDED INSTALLATION LOCATION FOR A FIRE DEPT '' . CONNECTION(FOCI IS BETWEEN THE MODEL EX DRY 4110.0 CONNECTION VALVE AND THE WATER SUPPLY CONTROL VALVE. WATER 1171_. SUPPLY _.``` ■ / VALVETHE CONTROL(BUTTERFLY)VALVE,ADJOINING COUPLING _ CONTROL ARE INCLUDED IN THE'FULLY ASSEMBLED TO MODEL EX JDRY PIPE VALVE WITH CONTROL VALVE'TRIMaFccm fj. CONFIGURATION ONLY,REFER TO PAGE 69 OF THIS 36II ``_ BULLETIN FOR PART NUMBER/ORDERING INFORMATION. THE CONTROL(BUTTERFLY)VALVE,INLET SPOOL,AND — ADJOINING COUPLINGS ARE INCLUDED IN THE'FULLY ASSEMBLED TO MODEL EU DRY PIPE VALVE WITH CONTROL VALVE W/INLET SPOOL'TRIM CONFIGURATION ONLY.REFER TO 1�_ � PAGE k9 OF THIS BULLETIN FOR PART NUMBER/ORDERING 1 INFORMATION, FROM SUPPLY Fig. 2 Hydrostatic Testing of EXValves andEXSystems Model EXLowPressure D ryP i peValve Description As required by NFPA 13, fire sprinkler systems with 1. Valve&System-Pressure Rated to 250 psi(17.2 bar)for working pressures up to and including 150 psi are to be 2"(50mm),21/2"(65mm),76mm and 8"(200mm)and 300 hydrostatically tested at a water pressure of 200 psi and psi(20.7 bar)for4"(100mm), 165mm&6"(150mm) maintain that pressure without loss for two hours. Fire 2. Factory tested to a hydrostatic pressure of (Valve only) sprinkler systems with working pressures above 150 psi 500 psi (34.5 bar)for 2" (50mm), 21/2" (65mm), 76mm are required to be hydrostatically tested at 50 psi above and 8" (200mm), 600 psi (41.4 bar)for 4" (100mm), the system working pressure and maintain that pressure 165mm &6" (150mm). without loss for two hours. In addition to the hydrostatic 3. End and trim connections: tests described above, dry pipe systems require an ad- • ANSI/AWWA C606 dimensions: ditional low pressure air test. In some cases, hydrostatic testing (in accordance with Nominal Outlet Groove Groove Outlet Face to the NFPA13 requirements noted above)will result in pres- Pipe Size Diameter Diameter Width Groove Groove sures that exceed the working Pressure of the valve and 2.375" 2.250" 11/32" 5/8" trim kit for the two-hour test period. The valve and appli- 2"(50 mm) (60mm) (57mm) (9.0mm) (16mm) cable trim kit have been tested,approved and listed under 2.875" 2.720" 11/32" 5/8" these conditions and as such, hydrostatic testing in accor- 2'/2"(65 mm) (73mm) (69mm) (9.0mm) (16mm) dance with NFPA 13 is acceptable. In addition, the clap- 76 mm 3.000" 2.845" 11/32" 5/8" per can remain in the closed position and the trim kit need (76mm) (72mm) (9.0mm) (16mm) not be isolated,as each has been designed to withstand 3"(80 mm) 3.500" 3.344" 11/32" 5/8" hydrostatic testing as required by NFPA 13. (89mm) (85mm) (9.0mm) (16mm) Hydrostatically testing the valve and trim to pres- 4"(100 mm) 4.500" 4.334" 3/8" 5/8" sures higher than their rating is limited to the hydrostatic (114mm) (110mm) (9.5mm) (16mm) test as referenced by NFPA13. It does not address the 165 mm 6.500" 6.330" 3/8" 5/8" occurrence(s) of a "water hammer" effect, which can in- (165mm) (161mm) (9.5mm) (16mm) _ deed damage the valve. A "water hammer" in the water 6"(150 mm) 6.625" 6.455" 3/8" 5/8" supply piping of the valve can create pressures in excess (168 mm) (164mm) (9.5mm) (16mm) of the rated pressure and should be avoided by all neces- 8"(200 mm) 8.625" 8.441" 7/16" 3/4" sary means.This condition may be created from improper (219mm) (214mm) (11mm) (19mm) fire pump settings, underground construction work,or an • Flange dimensions: improperventing of trapped air in the water supply piping. Flange Flange Nominal Bolt Bolt Fe Flange Number Type Pipe circle circle Hole Thickness of Bolts Technical Data Size Dr Dr Dimer Reliable Model EX Low Pressure Dry Pipe Valves,with ASME 4 71/2" 34" 9" /s associated trim,sizes 2"(50mm),21"(65mm),3"(80mm), 616.5 (100mm) (191mm) (19mm) (229rrm) (24mm) 8 Class 150 76mm&8"(200mm)are rated for use at a minimum water iso supply pressure of 20 psi(1.4 bar)and a maximum water 7005-2 4" 73//' 3i4" 9" 15/16" 8 supply pressure of 250 psi (17.2 bar),sizes 4" (100mm), PN16 (100mm) (180rrnm) (19mm) (229mm) (24mm) 6" (150mm) & 165mm are rated for use at a minimum wa- ASME 6° 91/2" I 7/ 11" 5/16' B16.5 ter supply pressure of 20 psi(1.4 bar)and a maximum wa- class 50 (150mm) (241mm) (22 m) (279mm) (24mm) 8 ter supply pressure of 300 psi (20.7 bar).Water supplied iso 6" 97/s' 29/" 11" 15/16" to the inlet of the valve and to the pushrod chamber must 7005-2 8 be maintained between 40°F(4°C)and 140°F (60°C). PN16 (150mm) (240-nm) (23mm) (279rrm) (24mm) The following list of technical bulletins pertains to valves ASME s° 113/4" 78° 131/2" 1" B16.5 and devices that may be used in this Dry Pipe Valve sys- class 50 (200mm) (298mm) (22mm) (343mm) (25.4mm) 8 tem: iso 7C05-2 g„ 115 „ 29/32" 13/z„ 1„ 12 Model EX Dry Pipe Valve R eliable 358/359 PN16 ( ''m) (295mm) (23rrrn) (343mm) (25.4mm) Mechanical Sprinkler Alarm Reliable 612/613 • Threaded openings Per ANSI B 2.1 Pressure Maintenance Device Reliable 254 Nitrogen Regulating Device Reliable 254 Model B1 Accelerator Trim Kit Reliable 323 Hydraulic Emergency Station(Model A) Reliable 506 Low Air Pressure Alarm Switch(Potter) 5401564 Waterf low Pressure Alarm Switch(Potter) 5400928 5. RELIABLE MODEL B1 ACCELERATOR KIT (P/N 6516000003) AIR PRESSURE GAUGE ,1 FROM MODEL EX m DRY PIPE VALVE SYSTEM TRIM u MODEL B1 ACCELERATOR V ik. 0. NIPPLE, 1/2"x 2" I �������� NIPPLE, 1/2"x 3" ji ""� ELBOW, 1/2" -AIM. �� NOTE: A MINIMUM OF 15 PSI BALL VALVE, 1/2" (1.0 BAR)OF SUPERVISORY AIR PRESSURE IS REQUIRED NIPPLE, 1/2"x 2" WHEN USING A MODEL B1 ACCELERATOR. SEE BULLETIN 323 FOR DETAILS VENT TO ATMOSPHERE 359FG04_A Fig. 3 MODEL B HYDRAULIC MANUAL EMERGENCY STATION ooa oma: jj 4. Valve Exterior's Color: System Air or Nitrogen Pressure Requirements Valve Size Color The system trim includes gauges to read the pneumat- 2" (50 mm) Black or Red is and water pressures of Model EX Dry Valve.Table A specifies the air or nitrogen pressure level to be applied 21/2" (65 mm) Black or Red to the Model EX Dry Pipe Valve.Optional Reliable Model 76 mm Red A-2 Pressure Maintenance Device(see Reliable Bulletins 3" (80 mm) Blackor Red 254)automatically provides a safeguard against pressure 4" (100 mm) Blackor Red leaks in the sprinklerpiping,and properly restricts the flow 165 mm Red of makeup air.When the optional Model B1 Accelerator is 6" (150 mm) Blackor Red used, a Model A-2 Pressure Maintenance Device and a tank-mounted air compressor are required.Also, when a 8"(200 mm) Blackor Red Model B1 Accelerator is used, to expedite water-delivery 5. Faceto face dimensions: time,the pneumatic pressure must not be less than 15 psi Valve Size End Connection: End to End: (1.0 bar). 2"(50mm), 21/2" Whenever multiple dry systems are installed at the (65mm), 76mm Groove/Groove 121/2"(318mm) same location,each dry system is to have its own Model &3"(80mm) A-2 Pressure Maintenance Device installed for individual Groove/Groove 14" (356mm) maintenance of air pressure (Refer to the 2007 Edition of 4"(100mm) Flange/Groove 16" (406mm) NFPA 13, section 7.2.6.5.3). Flange/Flange 16" (406mm) Groove/Groove 16" (406mm) Table A(For the fastest water transit time, use no &(165mm) Flange/Groove 19" (48 3mm) more than the"Best Performance Max"pneumatic Flange/Flange 19" (483mm) pressure) 8"(200mm) Groove/Groove 193/"(492mm) Water Pressure psi Pneumatic Pressure to be Pumped into Flange/Flange 211/4"(540mm) (bar) Sprinkler Sy stem psi(bar) 6. Valve Shipping Weight: Maximum Not Less Than Best Performance Max Valve Size: End Connection: Weight: 20(1.4) 8(0.6) 10(0.7) 2"(50mm), 21/2" 30(2.1) 10(0.7) 14(1.0) (65mm), 76mm Groove/Groove 34 lbs(15 kg) 50(3.4) 12(0.8) 16(1.1) &3"(80mm) 75(5.2) 13(0.9) 17(1.2) Groove/Groove 64 lbs(29 kg 100(6.9) 15(1.0) 19(1.3) 125(8.6) 16(1.1) 20(1.4) 4"(100mm) Flange/Groove 79 lbs(36 kg) 150(10.3) 17(1.2) 21 (1.4) Flange/Flange 92 lbs(42 kg) 175(12.1) 18(1.2) 22(1.5) Groove/Groove 95 lbs(43 kg) 200(13.8) 19(1.3) 23(1.6) 6"(150mm) Flange/Groove 122 lbs(56 kg) 225(15.5) 21 (1.4) 25(1.7) &165mm 250(17.2) 22(1.5) 26(1.8) Flange/Flange 138 lbs(69 kg) 275(19.0) 23(1.6) 27(1.9) Groove/Groove 148 lbs(67 kg) 300(20.7) 24(1.7) 28(1.9) 8"(200mm) Flange/Flange 197 lbs(90 kg) Note:During system set-up,a higher pneumatic pressure may be re- l. Trim Shipping Weight: quired in order to properly set the Model EX Dry Valve. Nitrogen used in refrigerated area systems minimizes a Valve Size: Weight: possibility of ice build-up and blockage inside the system 2"(50mm), 21/2"(65mm), 76mm 30 lbs(13.6 kg) piping that could inhibit proper system operation.The cal- &3"(80mm) culated nitrogen supply in lbs (kg) to pressurize various 4"(100mm), 6"(150mm), 165mm 34 lbs(15.5 kg) system capacities to 10 psi (0.7 bar) at different freezer &8"(200mm) temperatures is as follows: 8. Friction loss(Expressed in equivalentlength of Schedule System Freezer Temperature, °F(°C) Approx. 40 pipe,based on Hazen&Williams formula. Capacity 20 0 -20 -40 -60 Fill Time Equivalent Length: Gal.(L) (-6.7) (-18) (-29) (-40) (-51) (min*) Valve Size: C = 120 C = 100 CV 250 1.90 1.90 2.00 2.10 2.20 1 2"(50mm) 4.4 ft(1,3 m) 3.1 ft(1,0 m) 101 (946) (0.86) (0.86) (0.91) (0.95) (1.00) 500 3.64 2.80 4.00 4.20 4.40 2 21"(65mm) 6.0 ft(1,8 m) 4.3 ft(1,3 m) 236 (1893) (1.65) (1.27) (1.81) (1.91) (2.00) 76mm 7.7 ft(2,3 m) 5.5 ft(1,7 m) 241 750 5.50 5.70 6.00 6.30 6.60 3 3"(80mm) 12.6 ft(3,8 m) 9.0 ft(2,7 m) 254 (2839) (2.49) (2.59) (2.72) (2.86) (2.99) 1000 7.30 7.60 8.00 8.33 8.80 4 4"(100mm) 14 ft(4,3 m) 10 ft(3,0 m) 469 (3785) (3.31) (3.45) (3.63) (3.78) (3.99) 165mm 29.4 ft(9,0 m) 20.9 ft(6,4 m) 886 Note: (1 bar=100 kPa) Consult Reliable Bulletin 357 for more detailed information. 6"(150mm) 29.4 ft(9,0 m) 20.9 ft(6,4 m) 886 *When filled with the Reliable Model A-2 Pressure Main- 8"(200mm) 53.5 ft(16,3 m) 38.1ft(11,6 m) 1516 tenance Device having the bypass valve open. 9. Installation position:Vertical 7. Patents U.S. Patent Pending for a Dry Pipe Valve Arrangement Ordering Information Specify: • Valve Model, Size & End Connection- Valve Part Numbers Valve Size&End Connection Flange Type Color Reliable Part Number Black 6101021010 2"(50mm) Gry/Gry N/A Red 6101021015 Black 6101025010 21/2" (65mm) Gry/Gry N/A Red 6101025015 Black 6101031010 3"(80mm)Gry/Gry N/A Red 6101031015 76mm Gry/Gry N/A Red 6101051015 Black 6101041010 4" (100mm) Gry/Gry N/A Red 6101041015 ASME Class 150 Black 6101041020 4" (100mm) Flg/Gry ASME Class 150 Red 6101041025 ISO PN16 Red 6101041045 ASME Class 150 Black 6101041030 4" (100mm) Flg/Flg ASME Class 150 Red 6101041035 ISO PN16 Red 6101041055 Black 6101061010 6" (168mm)Gry/Gry N/A Red 6101061015 ASME Class 150 Black 6101061020 6" (168mm)Flg/Gry ASME Class 150 Red 6101061025 ISO PN16 Red 6101061045 ASME Class 150 Black 6101061030 6" (168mm)Flg/Flg ASME Class 150 Red 6101061035 ISO PN16 Red 6101061055 165mm Gry/Gry N/A Red 6101065015 ASME Class 150 Red 6101065025 165mm Flg/Gry ISO PN16 Red 6101065045 Black 6101081010 8"(200mm)Gry/Gry N/A Red 6101081015 ASME Class 150 Black 6101081030 8"(200mm) Flg/Flg ASME Class 150 Red 6101081035 ISO PN16 Red 6101081055 8. • Trim— The trim set is available in individual parts, in time-saving segmentally assembled kit forms, or fully assembled to the Model EX Low Pressure Dry Pipe Valve(with or without a control valve). TRIM PART NUMBERS: 2" (5OMM), 2-1/2" (65MM), 3" (60MM) Sc 76MM: INDIVIDUAL TRIM COMPONENTS(ASSEMBLY REQUIRED,EX VALVE NOT INCLUDED):6501030001 SEGMENTALLY ASSEMBLED TRIM(EX VALVE NOT INCLUDED):6501030002 4" (1O0MM), 6" (168MM), 165MM & 8" (2O0MM): INDIVIDUAL TRIM COMPONENTS(ASSEMBLY REQUIRED,EX VALVE NOT INCLUDED):6501060001 SEGMENTALLY ASSEMBLED TRIM(EX VALVE NOT INCLUDED):6501060002 FOR FULLY ASSEMBLED TO MODEL EX VALVE SEE THE PART NUMBER SCHEME BELOW: VALVE SIZE: PART NUMBER SCHEME: 2 2":2-1//2"((652 265MM) 3:3"(80MM) 4:4"(100MM) 5:76MM MISC OPTIONS: 6:6'(168MM) 0:BLACK VALVE 7:165MM A:RED VALVE 8:8'(200MM) B:RED VALVE WITH DOMESTIC TRIM PRESSURE SWITCHES: C:CHINESE MARKINGS ON VALVE 1:POTTER WITH UL/ULC/FM APPROVALS D:BLACK VALVE WITH DOMESTIC TRIM 2:SYSTEM SENSOR WITH ULC APPROVALS 3:SYSTEM SENSOR WITH UL/FM APPROVALS EXAMPLE P / N : 6506061010 CONTROL VALVE/ACCELERATOR: 0:WITHOUT CONTROL VALVE,WITHOUT ACCELERATOR END CONNECTION: 1:WITH CONTROL VALVE,WITHOUT ACCELERATOR 1:GROOVED INLET,GROOVED OUTLET 2:WITHOUT CONTROL VALVE,WITH ACCELERATOR 2:CLASS 150 FLANGED INLET,GROOVED OUTLET 3:WITH CONTROL VALVE,WITH ACCELERATOR 3:CLASS 150 FLANGED INLET,CLASS 150 FLANGED OUTLET 4:WITH CONTROL VALVE,WITH INLET SPOOL 4:PN16 FLANGED INLET,GROOVED OUTLET 5:WITH CONTROL VALVE,WITH INLET SPOOL AND ACCELERATOR 5:PN16 FLANGED INLET,PN16 FLANGED OUTLET NOTE: 76MM&165MM NOT AVAILABLE WITH CONTROL VALVE. NOTE: 2"(50MM),2-1/2'(65MM),3"(80MM)&76MM NOT AVAILABLE 4"(100MM),6"(168MM)&165MM WITH FLANGED INLET AND WITH FLANGED INLET AND FLANGED OUTLET OR FLANGED FLANGED OUTLET OR FLANGED INLET AND FLANGED OUTLET INLET AND FLANGED OUTLET.8"(200MM)NOT AVAILABLE NOT AVAILABLE WITH CONTROL VALVE. 8"(200MM)WITH WITH FLANGED INLET AND GROOVED OUTLET FLANGED INLET AND FLANGED OUTLET NOT AVAILABLE WITH CONTROL VALVE THE EXAMPLE IS A BLACK 6"(168MM)VALVE WITH POTTER PRESSURE SWITCHES, WITHOUT A CONTROL VALVE,WITHOUT AN ACCELERATOR AND HAS A GROOVED INLET AND GROOVED OUTLET 359FG11B Fig.5 9. • Additional equipment Component Part Mfgr. Description Technical Bulletin OS&Y - Water Supply Control Valve Select Butterfly, - Tamper Switch(Optional)for OS&Y Potter Valve Model OS&Y2 5400928 B TamperSwitch(Optional)for Butterfly Potter Model P1BV2 Valve 5400928 Dry Pipe Valve A Model EX Reliable 358/359 Dry Pipe Valve System A Refer to Parts in this Bulletin Reliable 358/359 Model PS10-2(DPDTcULus,FM) Potter Waterflow Alarm Pressure Switch B 5400928 Model PS10-2(DPDTVdS) Model PS25-2(DPDTcULus,FM) Potter Low Air Alarm Pressure Switch B 5401564 Model PS25-2(DPDTVdS) Mechanical Alarm(Optional) A Model C Reliable 612/613 Manual Emergency Station A Model A Hydraulic(Pilot Line)Type Reliable 506 Sprinklers A Closed Type Reliable 110, 117, 131, 136,etc. Air Compressor" C Per NFPA 13 F-30 Pressure Maintenance Device A Model A-2 Reliable 254 Accelerator Kit* A Model B1 Reliable 323 Nitrogen Regulating Device A Regulator with Optional Low Air Pressure Switch Reliable 254 *If the optional Model B1 Accelerator is used, a tank-mounted air compressor and an A-2 pressure maintenance device must be provided. Additionally the use of a tank-mounted air compressor helps to eliminate on/off compressor cycling that may occur as a result of small leakage in the air line between the pressure maintenance device and the 1/2" check valve, as well as due to ambienttemperature changes in the system piping. System Equipment Manufacturers (A)Reliable Automatic Sprinkler Co., Inc. (B)Potter (C) Gast Manufacturing Corp. 10. Nominal Installation Dimensions in Inches(mm) Pipe Size A B C D* D** D*** D****D***** E F G H I J K L M N P Q 2"(50 mm) 81/ 7 71/2 121/2 153/4 211/4 N/A N/A 101/4 203/4 121 41/2 83/4 63/4 71/4 63/4 16 6 11 93/4 (216) (178) (191) (318) (400) (540) (260) (527) (318) (114) (222) (171) (184) (171) (406) (152) (279) (248) 21/z"(65 mm), 81/ 7 71/2 121/2 161/2 22 101/4 203/4 121/2 41/2 83/4 63/4 71/4 63/4 16 6 11 93/4 3 (80 mm)& (216) (178) (191) (318) (419) (559) N/A N/A 76 mm (260) (527) (318) (114) (222) (171) (184) (171) (406) (152) (279) (248) 4"(100 mm) 81/2 71/2 71/2 14 183/4 241/4 16 16 111/2 22 151A 51/ 93/4 73/4 8 101/2 171/2 6 11 113/4 (216) (191) (191) (356) (476) (616) (406) (406) (292) (559) (387) (140) (248) (197) (203) (267) (445) (152) (279) (298) 6"(150 mm) 81/2 8 71 16 211/4 263/4 19 19 131/4 233/4 16 51/2 101/4 8 10 11 191/2 6 11 113/4 &165 mm (216) (203) (191) (406) (540) (679) (483) (483) (337) (603) (406) (140) (260) (203) (254) (279) (495) (152) (279) (298) 81/ 81/2 7Y2 193/8 251/4 303/4 211/4 131/ 24 161/ 51/ 121/4 9 71/ 121/4 191/4 6 11 113/4 8"(200 mm) (216) (215) (191) (492) (641) (781) N/A (540) (343) (610) (419) (140) (311) (229) (191) (311) (489) (152) (279) (298) D* is the takeout for a Gry/Gry EX valve only. D** is the total takeout for a Gry/Gry EX valve with a Reliable control valve or,for 2" (50 mm) valves only,Anvil control valve. Substituting a NIBCO control valve increases the total takeout to 22" (559 mm) for a 6" (150 mm) valve and reduces the total takeout to 243/4" (629 mm) for an 8"(200 mm) valve. D***is the total takeout for a Gry/Gry EX valve with an Inlet Spool and a Reliable control valve or,for 2" (50 mm) valves only,Anvil control valve.Substituting a NIBCO control valve increases the total takeout to 271/2" (698 mm)for a 6" (150 mm) valve and reduces the total takeout to 301/4" (769 mm) for an 8"(200 mm) valve. D**** is the takeout for a Flg/Gry EX valve only. D***** is the takeout for a Flg/Flg EX valve only. TRIM SHOWN FULLY ASSEMBLED WITHOUT CONTROL VALVE - C II N 4), J i wi. �� �_ _ irk.=�I ' ir......_.........,_...w_ l ■. 61.- � � Jill -- .11 SII/ `il� I�s��1l_ ,;a��He M�VIII iI4 F E !�' II■; IvasI� — ■I�� 111LX.- 11%1 LPCS ., Eilp ill 111 :11,11 i dirlr§-3120.7 BAR *Wort* .1 etirWil 1211111IP'k' i I r—- K A A A I i siii KO Illr t I 1, V I III O I II . Lipi H P - B I - Q - 359BKPC - - L G -- I 11. Reliable. . . For Complete Protection Reliable offers a wide selection of sprinklercomponents. Following are some of the many precision-made Reliable products that guard life and property fromfire around the clock. • Automatic sprinklers • Deluge valves • Flush automatic sprinklers • Detector check valves • Recessed automatic sprinklers • Check valves • Concealed automatic sprinklers • Electrical system • Adjustable automatic sprinklers • Sprinkler emergency cabinets • Dry automatic sprinklers • Sprinkler wrenches • Intermediate level sprinklers • Sprinkler escutcheons and guards • Open sprinklers • Inspectors test connections • Spray nozzles • Sight drains • Alarm valves • Ball drips and drum drips • Retarding chambers • Control valve seals • Dry pipe valves • Air maintenance devices • Accelerators for dry pipe valves • Air compressors • Mechanical sprinkler alarms • Pressure gauges • Electrical sprinkler alarm switches • Identification signs • Water flow detectors • Fire department connection The equipment presented in this bulletinis to be installed in accordanceviththe latestpublished Standards of the National Fire Protection Association,Factory Mutual Research Corporation,or othersimilarorganizations and also with the provisions of governmental codes or ordinances wheneverapplicable. Products manufactured and distributed by Reliable have been protecting life and property for almost 100 years. Manufactured by Reliable Automatic Sprinkler Co., Inc. A Recycled (800)431 1588Sales Offices vi1r Paper Reilabid (800)848 6051 Sales Fax (914) 829 2042 Corporate Offices Revision lines indicate updated or new data. www.reliablesprinkler.com Internet Address EG.Printed in U.S.A.11/16 P/N 9999970426 Page 1 of 6 NIKING® ACCELERATOR TECHNICAL DATA MODEL D-2 The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION The Viking Model D-2 Accelerator is a quick-opening device, with an integral anti-flood r • assembly,used to increase the operating speed of a differential type dry pipe valve.An . • accelerator (quick-opening device) is recommended on alI differential dry pipe valves and is required on dry pipe systems of certain capacities.Refer to NFPA Standards and v� Authorities Having Jurisdiction.The Viking Model D-2 Accelerator is a direct replacement E: I. for the Model D-1 Accelerator. Features • Pilot responsive • Refer to NFPA-13 for maximum system size k • Automaticallyresets • Integral anti-flood assembly =ti • Factory Tested 2. LISTINGS AND APPROVALS 0 UL Listed:VJPZ Scan with smart phone to access technical and troubleshootingresources. Me FM Approved:ACCELERATORS with Buil t-InAnti-fIoodingDevice. 3. TECHNICAL DATA 0 . .21 0 Specifications: Shipping Weight: 6.2 I bs.(2.8 kg) ■ ■ • Material Specifications: Refer Figure 2. 1 • 1.0: ■ Ordering Information: ■ Availablesince 1998 7 Part Number:09881 Accessories: VModel D-2 Accelerator Trim Kit(galvanized steel)for instal lationon Viking Model F The Viking Coral Data may be found on The Viking Corporation's Web site at Dry Valves(all sizes). Includes one air gauge. Viking Part No. 09730 http://www.vikinggroupinc.com. 4. INSTALLATION The Web site may include a more recent A. On Dry Valve Trim edition of this Technical Data Page. Verify that the water supply piping has been adequately flushed to reduce the opportunity for foreign matter to contaminate sprinkler piping and/or trim components.Install the Model D-2 Accelerator in the dry valve trim piping according to the Model D-2 Accelerator Trim Chart.The dry system air supply must be connected as shown on the trim chart.DO NOT expose the accelerator to the hydrostatic test. A CAUTION THE DRY VALVE CLAPPER MUST BE LATCHED OPEN DURING PERFORMANCE OF THE HYDROSTATIC TEST. FOLLOW INSTALLATION INSTRUCTIONS BELOW IN PARAGRAPH 4B:GENERAL INSTALLATION INSTRUCTIONS. B. General Installation Instructions The air supplyshould be from an automatic,regulatedand restricted source suppl ied with clean,dry,oil-freeair(or nitrogen). Devices used should be specifical I yl isted for such service.A Viking air maintenance device and an appropriately sized de- hydrator are recommended.When corrosive atmospheres and/or contaminated water supplies are present,it is the owner's responsibility to verify compatibility with the Model D-2 Accelerator and associated equipment. 1. Remove all plastic thread protectors from the openings of the accelerator. 2. Apply a small amount of pipe-joint compound or tape to the external threads of all pipe connections required.Take care not to al lowany compound,tape,or other foreign matter inside any of the nipples or openings of the accelerator or trim. 3. The Model D-2 Accelerator must be installed upright(with the air gauge opening at the top)as shown on the trim chart. Observe flow arrow, on bottom of accelerator, below the 1/2" NPT inlet. 4. Instal la 0-80 psi(0-5.5 bar)retard to 250 psi(17.2 bar),air gauge in the 1/4"(8 mm)NPT opening in the top of the accelerator. 5. DO NOT expose the accelerator to the hydrostatic test. Form No. F_010898 16.03.04 Rev 16.1 Replaces page 111a-f, dated November 25, 2013. (Added reference#2 to repair kit) Page 2 of 6 NIKING® ACCELERATOR TECHNICAL DATA MODEL D-2 The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1/4" NVI bauge Connection Upper 0,4 Chamber ;' "%1 RI �,� Cover Diaphragm ����® Antl-Flood A I� — _ 411010) `/ �� Assembly `� i� Actuator Rod .�Middle / ` ` - AO_____/ 0- Chamber .;��� 11- r AntHFlood ��l,l101d �`...W 11 ��, .� Assembly *;.��`�%�/.a.6 Lower ,A rt TSI , 172:711 ©: Chamber .D. ,�a0�,7I1�Y,®®�.9� 'J j�� �� � ,��9.4iNl�Bd�E :,% Locating Clapper -- "7 Sleeve Diaphragm „�rut, Screen 1/8" NPT ` 1/2" NPT ''' Inspection /_-1/2" NPT W" MI1/2' NPT Plug ` OutletInlet �6;5Outlet 1/2" NPT oBgy1'9,Y7/�7// Outlet 1-11..- SECTI❑N A-A Figure 1 A CAUTION THE ACCELERATOR ISOLATION VALVES ARE TO BE KEPT IN THE NORMALLY OPEN POSITION.DO NOT CLOSE, EXCEPT DURING HYDROSTATIC TESTING OR TO SERVICE THE ACCELERATOR. C. Placing In Service I. On Dry Valve Trim When the dry pipe system is ready to be placed in service,verify that all equipment is adequately heated and protected to prevent freezing and physical damage. 1. With the water supply main control valve CLOSED,drain all water from the dry pipe system. If the system has oper- ated, open all low-point drains and the system flowtest valve.Allowenough time to completelydrain the system. 2. Verify that the intermediate chamber of the dry valve is free of water. No water should fl owfrom the drip check when the plunger is pushed. 3. Reset the dry valve(Refer to individual Technical Data for the dry valve). 4. Close all low point drains,the system flowtest valve,and the priming water level test valve in the dry valve trim. 5. Observe the air pressure gauge on top of the accelerator.The gauge must read zero before the accelerator will auto- maticallyreset. It may be necessary to loosen,remove,and re-installthe accelerator air gauge (use the appropriate wrench)to vent trapped air pressure from the upper chamber, even when the gauge indicates zero if the air supply is on while performing this step. 6. Pressurize the system in accordance with recommended settings. DO NOT exceed 60 psi (4.1 bar). 7. When the air pressure on the accelerator air gauge equals the system set pressure, perform Dry Pipe Valve Priming Water Level Test described in Paragraph 6-B-I to verify that water is not present above the priming level test valve in the dry valve trim.Priming water is NOT required for Viking dry valves.If the presence of water is detected above the priming level test valve,the system may not have been properly drained.To verify that the system has been properly drained, repeat Steps 1 through 7 above as required. NOTE: STEP 7 IS REQUIRED ANY TIME WATER HAS ENTERED THE SPRINKLER PIPING. IF NO WATER HAS BEEN ALLOWED TO ENTER THE SYSTEM SINCE THE PREVIOUS PRIMING WATER LEVEL TEST,THIS STEP MAY NOT BE REQUIRED. 8. Open the main drain valve(located on the inlet of the dry valve). 9. Slowlyopen the water supply main control valve. 10. When flow is developed from the main drain,close the main drain valve. 11. Fullyopen and secure the water supply main control valve supplying the dry valve. 12. Secure all val ves in their normal operating position. 13. Notify authorities having jurisdiction and those in the affected area that the system is in service. 5. OPERATION (Referto Figure 1.) The accelerator operates on the principle of unbalanced pressures.When the accelerator is pressurized, air enters the inlet,goes Form No. F_010898 16.03.04 Rev 16.1 Page 3 of 6 c TECHNICAL DATA ACCELERATORMODEL D-2 The Viking Corporation, 210 N Ind ustrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com through the screen filter into the lower chamber and through the anti-floodassembly into the middle chamber.From the middle chamber, the air sl owl yenters the upper chamber through an orifice restriction in the cover diaphragm. In the SET position,the system air pressure is the same in all chambers.The accelerator outlet is at atmospheric pressure.When a sprinkler or release operates,the pressure in the middle and lower chambers will reduce at the same rate as the system.The orifice restriction in the cover diaphragm restricts the air flowfrom the upper chamber, causing a relativelyhigher pressure in the upper chamber.The pressure differential forces the cover diaphragm down, pushing the actuator rod down.This action vents the pressure from the lower chamber to the outlet,allowingthe inlet pressure to force the clapperdiaphragm open. The pressure in the accelerator outlet forces the anti-fl oodassembl y cl osed. On a dry pipe system the air pressure from the accelerator outlet is directed to the dry pipe valve intermediate chamber.As the air pressure increases in the intermediate chamber of the dry valve,the dry valve pressure differential is destroyed and the dry valve trips,allowingwaterto enter the dry pipe system. After the dry valve trips,water entering the intermediate chamber of the dry valve wil I fil I the trim piping connecting the accelera- tor to ccelera- torto the dry system. However, when the anti-floodassemblyis pressurized closed,water is prevented f rom entering the middle and upper chambers of the accelerator. NOTICE THE OWNER IS RESPONSIBLE FOR MAINTAINING THE FIRE PROTECTION SYSTEM AND DEVICES IN PROPER OP- ERATING CONDITION. 6. INSPECTIONS, TESTS AND MAINTENANCE A WARNING ANY SYSTEM MAINTENANCE THAT INVOLVES PLACING A CONTROL VALVE OR DETECTION SYSTEM OUT OF SER- VICE MAY ELIMINATE THE FIRE PROTECTION CAPABILITIES OF THAT SYSTEM. PRIOR TO PROCEEDING, NOTIFY ALL AUTHORITIES HAVING JURISDICTION. CONSIDERATION SHOULD BE GIVEN TO EMPLOYMENT OF A FIRE PA- TROL IN THE AFFECTED AREAS. Prior to performing any work on the system in which the Model D-2 Accelerator is installed,refer to technical data for the system and equipment used. The Viking Model D-2 Accelerator must be kept free of foreign matter, freezing conditions,corrosive atmospheres,contaminated water suppl ies,and any condition that could impair its operation or damage the device. It is imperative that the system be inspected and tested on a regular basis. The frequency of the inspections may vary due to contaminated water suppl ies,corrosive water suppl ies,corrosive atmospheres,as well as the condition of the air supply to the system. For minimum maintenance and inspection requirements,refer to NFPA25. In addition, the authority having jurisdiction may have additional maintenance,testing,and inspection requirements that must be fol lowed. A. Inspection I. After every operation,and each time water is allowed to enter the system: 1. Inspect the interior of the accelerator for the presence of water. Dampness or condensation may indicate that the air supplyis not being dried adequately.If water is allowedto enter the middle and/or upper chamber of the accelerator, it may contaminate the accelerator orifices and prevent it from operating properly. 2. Remove the 1/8" NPT inspection plug. If water or dampness is present,the accelerator must be disassembled(as described in Section 6-C-I I: Disassembly),cleaned,and dried. II. Inspection of Accelerators: Weekly inspection is recommended. If the system is equipped with a low air(or nitrogen)alarm,monthlyinspections may be adequate. 1. Check the air pressure gauge I ocated on the top of the accelerator.Air pressure in the upper chamber of the accelera- tor should equal the air pressure maintained in the system on which it is installed.A difference in pressures other than slight variation due to gauge calibration tolerancemay indicate gauge malfunction,plugged accelerator orifices and/or filters, or other maintenance is required.See Section 6-C ACCELERATOR MAINTENANCE. NOTE: STANDARD TOLERANCE ALLOWANCE IN PRESSURE GAUGE CALIBRATION MAY RESULT IN A SLIGHT VARIA- TION WHEN THE PRESSURE READINGS OF ANY TWO GAUGES ARE COMPARED. 2. Verify that alI other trim valves are in their normal operating position. 3. Check for signs of mechanical damage and/or corrosive activity. If detected, perform maintenance as required or, if necessary, replacethe device. Form No. F_010898 16.03.04 Rev 16.1 Page 4 of 6 c TECHNICAL DATA ACCELERATORMODEL D-2 The Viking Corporation, 210 N Ind ustrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 4. Verify that the accelerator and trim are adequately heated and protected to prevent freezing and physical damage. 5. Verify that the water supply main control valve is open and secure. B. Tests I. Dry Pipe Valve Priming Water Level Test, Low Air Alarm Test, and Non-Flow Accelerator Test for Dry Valves Equipped with a Model D-2 Accelerator and Installed Accordingto Model D-2 Accelerator Trim Charts: The priming water level test is recommended quarterly and each time the system is placed in service after water has entered the system.Al so,each time the system is placed in service after water has entered the system,it is good practice to repeat the priming water level test within one week.Testing is used to verify that the system has been properly drained and that no water is present above the priming level test valve in the dry valve trim after draining the system.Any water columning(accumulationof water above the priming level test valve)can slow or even preventthe dry valveclapperfrom opening when the dry system operates. Quarterly testing of low air alarmsis recommended.Semi-annual testing of accelerators is recommended.Conduct non-flow test when partial flowtest or ful I flowtest is not required: 1. Notify the Authority Having Jurisdiction and those in the area affected by the test. 2. Close the water supply main control valve supplying the dry valve. 3. Open the main drain valve(I ocated on the inlet of the dry valve). NOTE: PERFORMING STEPS 4 OR 5 OF THIS TEST WILL CAUSE THE ACCELERATOR TO OPERATE. HOWEVER,WITH THE WATER SUPPLY MAIN CONTROL VALVE CLOSED,AND THE MAIN DRAIN VALVE OPEN, OPERATION OF THE AC- CELERATOR SHOULD NOT TRIP THE DRY VALVE. 4. Dry valve priming water level test: a. Verify that the water supply main control valve is closed and the main drain valve is open. b. Close the air supply. c. Ful I yopen the priming I evel test val vein the dry val vetrim to check for the presenceof water. If the presence of water is detected,the system may not have been properly drained. Perform steps 1 through 7 in Paragraph 4-C-I of PLACING ACCELERATOR IN SERVICE on Dry ValveTrim. d. When the test is complete:If/when no water is detected,open the air supply and continue to Step 6. 5. Low-air alarm test and non-flowaccelerator test: a. Verify that the water supply main control valve is closed and the main drain valve is open. b. Gradual I yopen the priming I evel test val vein the trim of the dry val veto simul ate operation of the dry system.Observe and record the pressure at which the low air al arm operates. c. When the test is complete,continue to Step 6. 6. Close the priming level test valve. 7. Loosen(use the appropriate wrench), and remove the accelerator air gauge to rel ease pressure from the upper chamber of the accelerator, allowing it to reset. 8. Re-instal land tighten (use the appropriate wrench)the accelerator air gauge. 9. Al lowpressure to be restored to the dry pipe system and accelerator. 10. When air pressure on the accelerator air gauge equals the system set pressure, verify that the intermediate chamber of the dry valve is free of water. No water should fl ow from the drip check when the plunger is pushed. 11. When testing is complete, return the system being tested to service. Perform Steps 8 through 13 of Paragraph 4.0 PLACING ACCELERATOR IN SERVICE on DryValveTrim. C. Accelerator Maintenance(Referto Figure 2.) I. On Dry Valves To remove a Model D-2 Accelerator from the trim of the dry valve for inspection and/or maintenance: 1. Close the water supply main control valve and open the main drain(located on the inlet of the dry valve),placing the system out of service. 2. Isolate the accelerator from the system by closing the shut-off valves on the accelerator trim. 3. Loosen the accelerator air gauge to vent the trapped air pressure from the accelerator. 4. Loosen each of the pipe unions necessary to disconnect the accelerator from the trim. 5. Refer to Paragraph 6.11-B: Disassembly. II. Disassembly (Referto Figure 2.) 1. Remove the four cover screws(16a) from the base(15) using a 3/16"AI lenwrench. 2. Remove the cover(1) from the housing (7). 3. Remove the cover diaphragm assembly(2) from the housing (7) for inspection. Blow air through filters and orifice. Replacethe assembl yif unit is damaged or plugged.DO NOT attempt to wash or clean the filters or orifice.Water may cause them to become plugged,requiring replacement of the assembly. 4. Remove the actuator rod(4),actuator rod spring(5),and retaining ring(3)for inspection and cleaning.Repl acethe actuator rod(4) if it is pitted,corroded,or damaged. NOTE: REPLACE BOTH U-CUPS(10) WHENEVER THE ACTUATOR ROD(4) IS REPLACED. Form No. F_010898 16.03.04 Rev 16.1 Page 5 of 6 NIKING® ACCELERATOR TECHNICAL DATA MODEL D-2 The Viking Corporation, 210 N Ind ustrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services:877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 5. Remove the housing insert(6) using a socket wrench with a 1-3/8"socket. 6. With the housing insert(6) removed,the U-cup (10) and U-cup retainer(11) can be removed from the housing insert (6)using a tool with a diameter of 1/8" or less. 7. Remove the housing spring(12) from the housing (7). 8. To remove any other parts from the accelerator, the accelerator will now need to be turned over so that the base (15) is in the upright position. 9. Remove the four socket head screws(16b)from the base (15), using a 3/16"Allenwrench. 10. With the housing (7)now removed,the screen filter(9)can be removed using a tool with a diameter of or less. 11. Remove the anti-flood kit from the housing (7)using a Phil l ipshead screwdriver. 12.The clapperdiaphragm(13) can now be removed from the base(15). 13. With the clapperdiaphragm(13) now removed,the U-cup(10) and U-cup retainer(11) can be removed from the clap- per diaphragm(13) using a tool with a diameter of 1/8" or I ess. 14.The seat (14) can now be removed from the base(15) using a socket wrench with a 7/8"socket. 15. If the locating pin (17) needs to be replaced(offered individually,not part of a repair kit),remove it from the base (15) and replace it with a new one. III. Installation of New Parts To start install ingthe new parts,start from the base(15) and work your way up. 1. Install the seat (14) into the base(15) using a socket wrench with a 7/8"socket. 2. Before installing the clapperdiaphragm (13), the U-cup (10) and U-cup retainer(11) must first be installedinto the clapperdiaphragm(13). To install the U-cup(10) and U-cup retainer(11) into the clapperdiaphragm(13). a. Applythe Lithium grease(18) evenly spread on the U-cup(10) and U-cup retainer(11). b. Install the U-cup (10) and U-cup retainer(11) into the clapper diaphragm (13) with the tapered side of the U-cup (10) installedinto the clapperdiaphragm(13). 3. The clapperdiaphragm (13) can now be installed onto the base (15) by lining up the hole in the clapperdiaphragm (13) with the locating pin (17). 4. Install the new anti-flood kit onto the housing (7)with a Phil I ipshead screwdriver, making sure the Viking logo is in the upright position. 5. Prior to install ingthe housing (7)back onto the base(15), the screen filter(9)will need to be installedinto the housing (7), using a tool with a diameter of 1/4"or less. 6. Re-instal Ithe housing (7)onto the base (15) by lining up the hole in the housing (7),with the locating pin (17). 7. The accel eratorcan now be turned over so that the base(15) is in the upright position,and the four socket head screws (16b) can now be installedinto the base(15) using a 3/16"Allenwrench. 8. Turning the accelerator over so that the housing (7)is now in the upright position,the housing spring(12) can now be installedinto the housing (7). 9. Before install ingU-cup(10) and U-cup retainer(11) into the housing insert(6): a. Applythe Lithium grease(18) evenly spread on the U-cup(10) and U-cup retainer(11). b. Install the U-cup (10) and U-cup retainer(11) into the housing insert(6) with the tapered side of the U-cup (10) installedinto the housing insert(6). 10. Instal I the housing insert(6)into the housing (7),making sure that the center of the housing insert(6)I ines up with the housing spring(12) and using a socket wrench with a 1-3/8" socket to install the housing insert(6). 11. Install the actuator rod spring(5)onto the actuator rod(4). 12. Install the actuator rod(4) into the housing insert(6). 13. Install the cover diaphragm assembly(2)onto the cover(1). NOTE:THE COVER DIAPHRAGMASSEMBLYIS NOT PART OF THE REPAIRKIT.IT IS OFFEREDASAN INDIVIDUAL COMPONENT ONLY. SEE FIGURE 2. 14. Instal I the cover(1) onto the housing (7)verifying that the center of the cover diaphragm assembly(2)I ines up with the actuator rod(4). 15.The four cover screws(16a) can now be installedinto the cover(1) using a 3/16"Allenwrench. 7. AVAILABILITY The Viking Model D-2 Accelerator is availablethrough a network of domestic and international distributors. See the Viking Corp. Web site for closest distributor or contact The Viking Corporation. 8. GUARANTEES For details of warranty, referto Viking's current I ist price schedule or contact Viking directly. Form No. F_010898 16.03.04 Rev 16.1 Page 6 of 6 NIKING® ACCELERATOR TECHNICAL DATA MODEL D-2 The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone:269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com ITEM PART NO. DESCRIPTION MATERIAL NO. NUMBER REQ'D 16 i 1 -- Cover Brass Casting 1 I ! 2 05480B Cover Diaphragm Assembly Various, Nitrile 1 I 3 * Retaining Ring Stainless Steel 157 1 C. 4 * Actuator Rod Brass Rod 1 �` 5 * Actuator Rod Spring Stainless Steel 302 1 6 * Housing Insert Brass UNS C36000oils 7 Housing Brass Casting 1 8 05105S 1/8" Pipe Plug Steel 1 9 * Screen Filter Stainless Steel 304 1 10 * U-Cup Buna-N 2 1 11 * U-Cup Retainer Stainless Steel 302/304 2 12 * Housing Spring Stainless Steel 302 1 ® a 13 * Clapper Diaphragm Polyethersulfone/EPDM 1 �, 14 * Seat Brass Rod UNS-C36000 1 © \ 6 / 15 -- Base 16a & Brass Casting 1 c,:) 16972 Screw, S.H. 1/4"-20 UNC x 1" Zinc Plated 8 16b 17 05472A Locating Pin Stainless Steel 304 1 © a 18 Not Shown © * Lithium Grease Lithium Grease 3/8 oz. I --Indicates repl acementpart not available O *Indicates replacement partonlyavailablein a Sub-Assemblylistedbelow. I SUB-ASSEMBLIES O 2 6, 9 14, 14834 Repair Kit- Includes Air Gauge 18-19 lar 19 06057A Anti-FloodKit ORIENTATION0 iZi — VIEW _V NOTE: Repair Kit 14834 incl udesa cover gasket and four screws(1/2-20 x 2-1/4)that are not used on the 11 / Model D-2 Accelerator. 0 0 O \„..........— 0 :,..... o0 • oa wA` oo 0 yh , .9 ID ØQa \ i O \ ., IlWr ID \�40I ,,., I) ORIENTATION • e ,. 0 a et VIEW ••r � , 0 '/ 0 . 6. \ . . ® o 1 , /� ��e0 Denotes Assembly Sequence, 1/2' NPT Outlet �„---- numbers imprinted on part. Note that The plastic parts and rubber diaphragms are notched for proper Figure 2 assembly. Form No. F_010898 16.03.04 Rev 16.1 Replaces page 111a-f, dated November 25, 2013. (Added reference#2 to repair kit) Colt Series Excellence M atters - Specif _t! s 200 (a) Double Check Assembly A s E 300 (a) Double Check Detector Assembly FIRE&WATERWORKS losoh , Colt Features The AMES Challenge backflow assemblies - AMES offers the best performing, +' • • Closest competitor is more than easiest to service,lowest installed cost — . 360%heavier backflow assemblies in the industry. • Most compact design in the industry We challenge any backflow manufac- ■ Entire valve body and closure sleeve turer to disprove these claims,through manufactured from 300 - authoriz ed,3rd party testing. 1�. Series Stainless Steel A- 111.! eirt .. ._._,____ ,_______. 4.. Ailt• • I. 01 7 L • Approved - with gate valves or UL/FM • butterfly valves .11011 I 1 • Approved for horizontal,vertical or t ..'• "N" pattern installations i Check our Website for approval updates. . -. • • _ _ — 0 1 '` ■ Utilizes groove connections for ease —— illi of installation &pipe alignment • Patented Link-check modules allow _ _ ease of serviceability F - ■ Smallest enclosure _ — J _ IC -i- 17------------1 ■ Eliminates flowswitchfluctuation . ■ Made in USA IN . • _ __ The AMES Challenge Assembly Weight Layylength Compare 4" Double Check With-Shutoff Valves Compare 4" Double Check With Shutoff Valves Backflow Assembly W eight (lbs) % Heavier Backflow Assembly Lay length (in) % Longer Than AMES Than AMES Colt 200 W/BFG 61 Colt 200 W/BFG 29.3 Febco 850 W/OS&Y-GPC5/O1 312 411% Febco 850 W/OS&Y-GPC5/01 46.2 59% Wilkins 350 WIGS&Y-BF350 281 360% Wilkins 350 W/OS&Y-BF350 37.7 29% En • ineer in • the Curve Colt 200/300 Certified flow Characteristics (Including OS&Y shut-offs) Colt 200 - 300 2.5" 3" P-1 18 18 • 16 16 •� 14 14 up 12 12 O 10 10 8 - 8 N 6 6 • 4 ` - 4 _1 V) _.•81111111111111111..'-- 2 - 2 N 0 0 4.1 0 100 200 300 400 500 0 500 1000 1500 2000 2500 Flow rate in gallons per minute Installation Guidelines Most field problems occur because dirt or debris present in Interior Installation the system at the time ofinstallation becomes trapped in the 1st check seating area resulting in a low or zero differ- ential across the 1st check. The system should be flushed !I PI before the backflow valve is installed.If the system is not flushed until after the backflow valve is installed,remove both check modules from the valve and open the inlet shut- offto allow water to flow for a sufficient time to flush debris from the water line.If debris in the water system I I continues to cause fouling,a strainer can be installed upstream ofthe backflow assembly. AMES models 200&300 may be installed in either horizontal,vertical,or"N"position as long as the Enclosure installation backflow assembly is installed in accordance with the direction ofthe flow arrow on the assembly and the local water authority approves the installation. 12"min The assembly should be installed with adequate clearance around the valve to allow for inspection,testing,and servicing. 4.1.1011 Twelve inches should be the minimum clearance between the lower portion of the assembly and the floor or grade. • Colt 200/300 dimensions & weight • - Ill kil d1!iIi 111* i h i All 1111 E ��IIJi II!$ I CtItl. Zil.,.. i'iir*\ piolm -0,4- 4 . 1. ,1), . _ . .. 54,,,,,,,,,,,,,,oz, , 1,...„,„.0 ,:i. F200 -- H A D F300 ith gate valves (Inches) W ith ul/fm butterfly valves (Inches) OS&Y NRS OS&Y BFG Size A B B C D E F/200 F/300 Weight A B C D E F/200 F/300 Weight 21/2" 31 163/s 93/8 31/2 22 151 93/16 133/16 1251bs 28 111 31/2 22 14X5/16 9 13 56 lbs 3" 3111/16 187/8 101/4 311/16 223/4 173/8 101/2 141/2 1451bs 281 12 31'/16 22 3/4 15 7/16 91 131 54 lbs 0+10..1 4" 3311/16 223/4 123/16 4 24 181 113/16 153/16 161 lbs 293/16 125/8 311/16 24 161/4 10 14 61 lbs 6" 44 301/2 16 51 333/4 233/16 15 19 2951bs 361 15 5 333/4 1911/16 101 141 117lbs 8" 50 373/4 19�5/i6 611/16 405/8 27/16 173/16 213/16 4801bs 43 183/4 61/2 40% 235/16 143/16 183/16 261 lbs 10" 571 453/4 2313/6 83/6 50 321/2 20 24 781 lbs MilMil UL/FMB utterfly valves available for shutoff valves Advantages of UL/FM - butterfly valves . J • Butterfly valves have built-in tamper i - sw itchw iring a.■ Backflowassembly is lighter .i, &more compact • Groove couplings allow ease of _ "N" p a t t e _ installation&pipe alignment 1 • All butterfly valves display flow 0 -.m.--indicator flag I q "• is -41# A _ L 1- + _�., llir--1 Horizontal lailw - - � '; riir ,-- . LL. - _ _ . . • 1 -it I. `' 1 Vert,Iiiillill 1-7 • ,... iipoilligili .0•44 I ical i ' 1 - Cutaway View - fu 11 flow operation Applications — Colt 300 Double Check Detector Check Assemblies are used to pre- vent backflow ofpollutants that are objectionable,but not toxic.Double Check Detector Check Assemblies may be 300 Series installed under continuous pressure service and maybe subject Stainless Steel Body to backpressure. and Sleeve The Double Check Detector Check Assembly is used primarily on fireline sprinkler systems when it is necessary to monitor Replaceable unauthorized use of water. seat-discs Quick Approvals access Contact the factory or visit the website: sleeve www.amesfirewater.com Specifications The Backflow Assembly shall consist oftwo independent . Link-check modules within a single housing with sleeve access,required test cocks and drip tight shut-offvalves. Link-checks may be removed and reinstalled in housing without 1 any special tools.The housing shall be constructed of300 Series stainlesssteel with groove end connections.Link-checks I shall have reversible elastomer disks and in operation shall produce drip tight closure against the reverse flow ofliquid t . .ii caused by back pressure or back siphonage.Device shall be 4 manufactured in the USA.Device shall be COLT 200 or 300 I manufactured by AMES ofSacramento,California. II C haracteristics and materials Rated Working Pressure Hydrostatic Test Pressure ' 175 PSI 350 PSI • #3 test cock • Temperature Range Body Construction 33 F-140 F 300 Series Stainless Steel Link-check modules End Connection Groove per AWWA C-606(IPS)or Flange per ANSI B16.1, I Normal operation Class125 In normal flowing operation,the independent Link-check remains closed until there is a water demand.Each check will then open and maintain an approximate 1 PSI differential in the direction offlow.In a nonf low or backflow condition, both checks will close until the resumption ofnormal flow. Applications — C olt 200 Double Check Assemblies are used to prevent backflow of pollutants that are objectionable but not toxic.Double checks may be installed under continuous pressure serviceII and may be subject to backpres sure. AM ES M Double Check Assemblies may be used in fire protection FIRE&WATERWORKS systems without chemical additives,industrial in-plant Division of watts Industries plumbing systems and other systems requiring low hazard 875 National Drive Suite#107 protection.Local codes may vary,consult authorities for Sacramento,CA 95834 specific approved applications. Phone 916.928.0123 Fax 916.928.9333 S-COLT-200/300 0308 P a t e n t Pending www.amesfnewater.com f .• .-. S(HEDULEIO 840 ._.. . . ror:A • .. „ pv," 0 lip .--k.!-! P.. Ilesialwpi... WI. ' *� .' f = • lt_ I._ ,� Alwaysreadyto protectyourmostvaluableassets. As the leading supplier of steel sprinklerpipe,we understand that there are no second chances in fire suppression.You need products of enduring quality and exceptionalstrength-plus reliable service.You need Bull M oose. Bull Moose Fire Sprinkle rPipe Prod uctlnformation Nominal Pipe Size(Inches) 1" 1-1/4" 6" 8" 0.D.(in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 6.625 8.625 1.315 1.660 1.900 2.375 2.875 3.500 4.500 R ID.(in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 6.357 8.249 CQ 1.049 1.380 1.610 2.067 2.469 3.068 4.026 LUEmpty Weight (Ih/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 9.290 16.940 LU 1.680 2.270 2.720 3.660 5.800 7.580 10.800 Water Filled Weight (lb/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 23.038 40.086 —I 2.055 2.918 3.602 5.114 7.875 10.783 16.316 G C.R.R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 1.158 1.805 0 1.00 1.00 1.00 1.00 1.00 1.00 1.00 LL1 Pieces per L ift 91 61 61 37 30 19 19 10 7 LU 70 51 44 30 30 19 19 u LiftWeight (lbs)21'lengths 2,695 2,319 2,677 2,051 2,224 1,732 2,242 1,951 2,490 1=. 2,470 2,431 2,513 2,306 3,654 3,024 4,309 N L iftWeight (lbs)24'lengths 3,079 2,650 3,060 2,344 2,542 1,979 2,563 2,230 2,848 VI 2,822 2,718 2,872 2,635 4,116 3,456 4,925 LiftWeight (lbs)25'lengths 3,208 2,760 3,187 2,442 2,648 2,062 2,670 2,940 2,894 2,992 2,745 4,350 3,601 5,130 SCHEDULE 10 B 40 ADVANTAGES: OTHER BENEFITS/SERVICES: • UL listed(US&Canada)and FM approved • We have the most stocking locations in the industry, • ASTM A135 and A795 Type E,Grade A Certified for best delivery and availability • Plain end or roll groove • Complies with NFPA-13,13R and 14 • E ddyGuard II'bacterial-resistant internalcoating • Industry-leading hydraulic characteristics • Custom length options • CRR of 1.0 and greater • Hot dipped galvanization • All pipe NDT weld tested • Reddi-Pipe®red or blackpipeeliminates field painting • Compatible for use in wet,dry,preaction and deluge sprinkler systems Exclusive maker of Redd i-Pipe® • The only maker with E PDs(to help earn LEE Dpoints). RED OR BLACK PAINTED PIPE. GI 4 CERTIFIED c °� us LISTED n:a. EA APPROVED NFPA' `" t- Lailo. 1446 A 800.325.4467 Milliallill 11 MULL MOOSE sales®BullMooselndustries.com IIIIPI - TUBE :u IMooseTube.com IPS CARBON STEEL PIPE- FIRE PROTECTION PRODUCTS 1 0.0 3 VICTAULIC® IS AN ISO 9001 CERTIFIED COMPANY Fire Lock® Fittings PRODUCT DESCRIPTION FireLock®products comprise a unique system specifically designed for fire protection services.FireLock full-flow elbows and tees are a CAD-developed, hydrodynamic design that has a shorter center-to-end 40/jir dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain --"'",iir. similar flow characteristics as standard full flow fittings. • Ilp' FireLock fittings are designed for use exclusively with Style 005 and Style 009 FireLock couplings. Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock Style 005 couplings. // a f a` Patented See Victaulic Itilrpublication 10.01 ,. for details. DIMENSIONS C to E No.001 No.003 No.002 No.006 Cto(,, , Fitting Size 90°Elbow 45°Elbow StraightTee Cap p .� Actual Ap rx. Ap rx. Ap rx. Thickness Ap rx. fi ��,s� p oo Nominal Outside C to E Weight C to E Weight C to E Weight "T" Weight C T Diameter Diameter Inches Each Inches Each Inches Each Inches Each to d Inches/mm Inches/mm mm Lbs./kg mm Lbs./kg mm Lbs./kg mm Lbs/kg 11/4 1.660 - - - - - - 0.82 0.3 No.001 No.003 32 42.4 - - - - - - 21 0.1 C 11/2 1.900 2.75 1.2 1.75 0.9 2.75 2.0 0.82 0.4 to E i 40 48.3 70 0.5 45 4.1 70 0.9 21 0.2 - - -� .-T -II \ ,....a It 2 2.375 2.75 1.7 2.00 1.8 2.75 2.4 0.88 0.6 50 60.3 70 0.8 51 0.8 70 1.1 22 0.3 ▪ oho to 21/2 2.875 3.00 3.1 2.25 2.2 3.00 3.6 0.88 1.0 E 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 I 3.000 3.00 3.30 2.25 2.4 - - - - No.002 No.006 76.1 mm 76.1 76 1.5 57 1.1 3 3.500 3.38 4.0 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 4.250 4.00 5.7 3.00 5.1 4.00 7.5 - - 108 mm 108.0 102 2.6 76 2.3 102 3.4 - - 4 4.500 4.00 6.7 3.00 5.6 4.00 8.7 1.00 2.4 100 114.3 102 3.0 76 2.5 102 3.9 25 1.1 5 5.563 4.88 12.6 3.25 8.3 4.88 15.7 1.00 4.1 125 141.3 124 5.7 83 3.8 124 7.1 25 1.9 159 mm 6.250 5.50 12.6 3.50 9.2 3.50 17.9 - - 158.8 140 5.7 89 4.2 140 8.0 - - 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 10.3 25 2.7 8 8.625 6.81 25.5 4.25 20.4 6.94 38.7 1.13 12.7 200 219.1 173 11.6 108 9.3 176 17.6 29 5.8 8 REGISTEREDTRADEMARKOF VICTAULIC-©COP YRIGHT2006 VICTAULIC-PRINTED IN U.S.A.-SKU#WCAS-67 PJUX 1539 REV F United States•Pho ne:1-800-PICK-VIC(1-800-742-5842)•Fax:610-250-8817•e-mail:pickvic@victaulic.com Canada•Pho ne:905-884-7444•Fax:905-884-9774•e-mail:viccanada@victaulic.com Euro pe.Pho ne:32-9-381-1500•Fax:32-9-380-4438•e-mail:viceuro@victaulic.be UK•Phone:44(0)1438741100•Fax:44(0)1438313883•e-mail:viceuro@victaulic.be Central and SouthAmerica•Phone:610-559-3300•Fax:610-559-3608•e-mail:vical@victaulic.com I Cta L 1 I Co Australasia•Phone:86-21-54253300•Fax:86-21-54253671 -e-mail:vicap@victaulic.com 10.03 FLOW DATA Frictional Resistance Fitting Size Equivalent Feet/meters of Straight Pipe Actual StraightTee Nominal Outside No.002 Diameter Diameter 90°Elbow 45°Elbow Inches/mm Inches/mm No.001 No.003 Branch Run 11/4 1.660 1.5 0.8 3.7 1.5 32 42.4 0.5 0.2 1.1 0.5 11/2 1.900 2.2 1.1 5.5 2.2 40 48.3 0.7 0.3 1.7 0.7 2 2.375 3.5 1.8 8.5 3.5 50 60.3 1.1 0.5 2.6 1.1 21/2 2.875 4.3 2.2 10.8 4.3 65 73.0 1.3 0.7 3.3 1.3 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 1.4 0.7 3.4 1.4 3 3.500 5.0 2.6 13.0 5.0 80 88.9 1.5 0.8 4.0 1.5 108 mm 4.250 6.4 3.2 15.3 6.4 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2.1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 6.4 2.6 159 mm 6.250 9.4 4.9 25.0 9.6 158.8 2.9 1.5 7.6 2.9 6 6.625 10.0 5.0 25.0 10.0 150 168.3 3.0 1.5 7.6 3.0 8 8.625 13.0 5.0 33.0 13.0 200 219.1 4.0 1.5 10.1 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. MATERIAL SPECIFICATIONS Fitting:Ductile iron conforming to ASTM A-536, grade 65-45-12 Fitting Coating:Orange enamel • Optional:Hot dipped galvanized This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions. Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. 2 FireLock® Fittings FPR CARBONTETIOSTEEL PIPEO10.02 FIRE PROTECTION PRODUCTS 3 iCt�UIGC° Style 005 m e,00,........ .. Vie "lis FireLockTM co,ket System Rigid Coupling with Vic-Plus'• Gasket System PRODUCT DESCRIPTION Flelock' Style 076 ngkf Sprinkler Systems.Angle- ONLY on vire protection coupling has a unique,pat- pad design pumas ascerri- systems. ented angle-pad design Gly by removing cne nut/ Vic-Plus Casket System: which a6oxs Ute housings tole and sover the Vlcuulu•non offers a gas- tooffsetwpalnping the housinduces the gasket. kIcta ICmwhtchrega gas- groom.•.. ' grow s.By pecmmng the This reduces components r10 field lubrication.The s housings to slide on the to handle during assembly: VIc-Pludt System(patent _ angled bolt pads.rigidity Is speeds and eases ed to tbn an pipe grooved to p%ldmg)is dry.deans and nen-toNctaub.spentsmtims. ass&n]ac It reduces =atK:•s The Fire lock coup/rigs and ek'rytime sueemessgy provide rigidity for valve Style 006 FSreLock coo- and ebrnlrutee the MESS g,,�,, connecnons,&emains and pliug�n-iU3 the Via and chaeta of ill 1 king straight inns. Support Plus Casket System o'er-lubncauon. i and hanging requirements are designed and rec- p _ Ir, n correspond to NFPA 13 =mended[or use f LPG eV lea rear(... -1 VdS aro oroaonpye L _ . DIMENSIONS 32E Ma Max. 4bw. OrtmncIonc Nomura Won. End Plot End QaootNdl Inobec: Aprx. y Ino10c Prc4c.9 Load Sro.t NO..ilia N9f Ea. F1 PU'• Lbo :, n: Ino9ec: x v Z L>:: . d�aui 1 a 3W 1E5 C .5 2.51X: ..]c 4 E iii L*D : ; :5C 75 .5 3.%X3 -- !✓ - liar - :5C 1523 C .' 2-%X275 ].eC f .f .. Rated fa wet andel :punka - 2lYinat350PS11Z41tSkPa)fcc 26 25f Z23 C . 2.%X275 aC : - - t%-d'(@.d-779.3 mmUa:eda , _ and 300 PSI(2069IPa)kcd%- 76.1 ern 3w zas C :' 2-%X275 - - ▪ -- B'Me-219.1=Orr-cc 3 3W '2E5 C :' 3.%X236 a(' . .. _ Schedule 10rok grooved of Schedule 40 cut ccrea grooved 4, 350 55E5 C 't . _ wed pre,Style 095anod and ' . 2413 2-%X 26I dws du accommodate°gun- IP]emm41:55 C '( 2.%X' • S.E.:: _ - am Lsaerma or anguli ' d+SMlm. S :3m '393 C '( 2-%X236 dee - . . e330mm )» 6x95 [ 't 2-%X236 :€] : :: - ' 15 f 3m)mm 362 'RS C 't 2-%X236 (.ee a:c _ a.� —. 6 300 ,(gel C 't _ 5 G - 3.%X26 t2C - -- -. 1520 cm >m ;COO [ 't 2.%X41,.: I .2 _ 5.5 - e6iemm VAS C,f 2-%X 2% . : • - 55 6 32 67625 0..19 2.%X41% - - •05}Maar an:mmreY2 Vb91k•Wad011rtlpnbs•P.O.B0x31.Ental PA 10114951 •OB01 KES.Vf55wa 6U.fl%0LPA10747.1410PICKNC•fAK:6101250a17•wesMciwitam .aaMt Coo e49101e:e luinatsVa.c OOP, t of N74 11,6•1 eatP5A MATERIAL SPECIFICATIONS Housing Duct&ton codcan- roc.and Approvedlay Factory Bokc/Nutu:Hex treated au. baa to ASPM A-395,grade E& Mutuat Pasaxch Is wet and Ga none.:ur ekxtrophmd m 45-15.and ASTM A-535.grade dry(cd free an)spsmkhr pop ASTM Bd37:T3ak Gad lack 85-0512 vMas up to the:and Waking conturrang to ASTM A-193 Howling Caen Orange Fcossure usln3 the G.nda'B' mtu.-la:atasn3a 1101X0 PSI animal 'Pipe A Mc-Run Gasket 17E5340 kPal.i7amed henna 3 Optional Not dipped gab•} Syst.aa roqumag nil 6atl contkcmmg to A-563. =ad 1ubctcntan G::da A Gasket Pa dry sa .:an2.Vimnhc t Swdrd gala asRmblalpawl 3 Grade"E"EPDM- A conurum to:woauacedtb. air m dy PP.therm la-ST PSyyaTteyepmo used Grade R' p cam?IJo t&c9smxd Tram a ix- Vic-Plus Gasket eclat wddal.FrcL:lkt RmhSwM VRI Type cowitviy�opam woe Mann nos <dl.as butt bean Lb-Nd ly System Gannet Vataula fin I.UNC) Vttaac mows w wan. U•acwrnms LSmtmas details. roma use a neesosl"shat tv Tis int:<mama rFcc &d hcLov is hazel on the Iatat hstm-and approvaldata at the tune d FFuncatron LaaaagrJAp�c J Gria:: are to anjaand cc:flit: by the app:cndsagmacs,Contact Vtctaubc Ba peixmance en ahs papa and the laa.t4.-tray and app4—mb.. Read Wonrg Preach" RYAd Nose"Fromm Pepe Ste Pipe Ste 3onedme imam IR ULC FM torod.a holm U. MC FM 5 P4.3 175 ITS ITS 9 2 a 360 300 3 14.4 353 350 350 6 175 175 ns 1040 • 5-B 300 300 TO SF 114.a 300 300 39 BLT 14.2 300 300 90 Separ.0 114.3 300 330 39 O4•A 300 300 90 TL 114.3 300 300 39 6 175 175 ITS WLS 114.2 300 300 39 GT 14.2 300 300 90 XL/XL-II 114.3 300 300 39 EL 14.2 39 300 39 NOTES: S:da o LWY/AF19md EL:o6xs to LlttoS•Aprowel Mapx 6006 rakes to Lbmo/ `Oc1teala 5 seed spm43x papa. Eddyme use rvcln'Ix pp* AFpcaatd Sups CO a Sups XL 10 Was mL tod/ApFcwod mtIdaxmed CY Ball MxmoTuba stmt pipe mmulatved =o212/2 10 Acca sptYa pia Co. ty Maud tato fG Canddl 0 ache to Lmed/App<mOG E3 Wmto Letoo/App<mnd fmFaatls. adubm:tad�mna Pia E3-Fba radspmbs pp WLS talars to LSmd/AFprowd rondamacd ty Hammon Ppb stmt sprodOx papa=nub:tmad ELT::Ac to Llshlappcvwd Sc Catag Co. Cy WTmmMadTuba Calpmy. ty htiD:anTtox pipe map:ny cG 31:ram'to ilmed/A Vd XN6.3:dm to bXtd/ entad M'A1rta:anTotaCrchpxy 36p6:-Tr stag spmv.Mcpppa XL or XL-13 Mimi ap:mm:;tpo OF bac to LuterAppow0 mxivaxe:cd ty Areal Tito ala mmplmcwtaa 7/Altai Tuba and Dyna-now stmt spnalds pipe Ccadcr CxTaltios Gandtut Cap:canal. mmaamdea by A-nalrlTW 31:3.1:2 to LineG/Ancow.,6 Real OrccoYub=mat amzalbY O T:alias tLIrtal••Apprcvvl Oyaa Women Tubo Sad and= Tame!stag pt a Ppa Capsanat mua'Eamxod ay A-nalaa Tuba ▪ Y NOTES 'Waal Aerate cm End Lonnie bb.tan L imams aid aeboISbtat anedcn sward'xa7t/LP1SI saelppa.slavraMaougrr-vbaarca- arcevnnW &flospexlcarona consul Waldo 1xpaanpxa on mu pipe WARNING:FOR CM TIME FIELD TEST CULT.ma Med nn.g W ewng Prorate MY/OS aaearod b In lob Ito elgarot WC In, 7 Fs naalnaadbn cdy.Rroma Bra pngt re awrady it 3 and adr<t emdnmpdho epma:4CMTac10n 0 Neta M tab imam'o:eat nurse d avail?meant More bred no bob ye Wa1W Iola mdadgodala M aoplrg eat tpxl immi.Cora Wale b m1S gStye 0:6 ooupb92 wadi am LPGApprowa b 12 Si,ZITS P66. WARNING:Pang smuts mud amyl maapca.nm and aawa bbt re aa.ping climonsy en shwa a anyVManes ping peWacb, 71npcda dm' ....Wn.rSbteweta-wry uwau..Owl Se lodmameahe.Meaon Rewe salts waist*Nenters. Vault mown Mrgl..Nay.puha Mok.p...6.gr.vtl.a, .,d*gran whoa rote anitskosming]Wren 10.90-2 Print Page 1 of 1 45° ELBOW =i h Pl4Y.fiR Dysi:1 N 1fr.'L'+mna+fl JRI�YI� Ductile Iron MATERIAL SPECIFICATIONS • Ductile iron threaded fithings are UL ULC Listed S. Factory Mutual Approved for 500 psi service_ ', Ductile iron per ASTM A536 Class 65.45.12. Dimensions conform to ASME B 16.1 4 Threads are NPT per ANSI/ASME B1.20.1. NOTICE Wok.oapriaPirgehav9hrghgri#nrlpfrarrcrththan Jo4;ff0011 pp, rF,rr4foro,over figFaninq nm caar•da<rsayob pipe Good,xlich .ay cause leakage 150,13.,r<:•' '.'}t should br r.sjhbered IIreP I4rr4 Inrwel 119nd li k,byr frp mo-r.. No•I..rns 45° ELBOW APPROVE Far L climgAlpra,ai NitaIFt H orriut5i�r rlE I1 ni Oe6ei it Ale x.5'�e�iiig Dire'e suis 14pprax. andLlrrdtatiuna'dolt nu She YY4h Il!n-Ir 14urbrr PrcFsrrr' ,. • • _hcl rr. Y rtacmorSanlser#n And hrAm1191ar"Solas kpnwrietlyd. 7"1 ; rt' cls fJ i =i7031r PP4 033 S,lp 1 1: {8 �!C 8140#421•11 Walt E.30 129 I;' f'.78 1i3 84op031i6 060:155 SpU 1.43 1 :at if 8p31SS PP4541;'• 1.88 • •Lt.s14C 4 phi Pryc7ur*Rmingr Fcr add dianal Iinirrgr and apprarals,see fhe imlwed dila raaen. SPF CEa&ductile.Iron Fittings www.anviatar.corn (1ANV-167 http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=1963 11/2/2011 Print Page 1 of 1 900 ELBOW Foo Prairr Milan of An t NremeLena Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings ore UL&ULC Listed 8. factory Mutual Approved for 50.0 psi service. Ductile iron per ASTM A536 Class 65.45.12. Dimensions conform to ASME B16.14 Threads are NPT per ANSI/ASME B1.20.1. Nowt 4rQn tThr31.ha4eh Oer rror flsrlgnrhpiciI+rsl Poe Thergrora,ovgr ii *army CC."..-,uso damage io pipe iFrpds v1,idi rna1 caurebakogo-ow/14.w f... ,.P'vold beiigi erred Ives Irma ^'*!^'"d trnd liylti,kryr r4 rnx-1-. .-. ,F.—, 90" ELBOW nf�aR0lffo For ListIngirkprprvoM E L Hanna! a AnrI lirm UnirFrsli !i .4lo king Itimeosioes Applax d LIIMilgrg4tsaQrYhbdslr norther Nem6er Prr'vre' Th.loch MWrF PrrY+hrt7/GGIrs 4rLWrt7Ft an AmINIArrIlSti r'Sa R.prrtortsOri. •• EdLCOXIt3 160k44 • I tidrr ?34 (10)054. BI 1- •UL,ULC .FM Prsssu:a Faohngs far addilienalhsri ow:molt,teolho reelyio5Idalesreean. ®16sannik; SPF Cast IS,Ductito Iron Fittings vwuw.aswils ar.ccm http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=1962 11/2/2011 Print Page 1 of 1 COUPL' ar- Ins Watch Cf. r1JYra hrnmri1 rFr�v> Ductile Iron MATERIAL SPECIFICATIONS Ductile iron threaded fittings are UL&ULC listed g factory Mutual Approved far 544 psi service. Ductile iron ger ASTM A536 Class 65-45.12. Dimensions conform to ASME 816.14 'Threads are NPT per ANSI/ASME B1.2 0.1. NOTICE .'7104 4ron H ngt ha,mil h oper lanmle areegth.rinn rh41 vd OW ppe TheraForargvor 119hlann%coo caus4 dorna9aio ppalFnodr which may caure4akago Dadre.ron Te. 1-rhooId be1.gi erred Ihr.1.*hurry bound Iund tishr,kyr ro mqr;figs Eyx hi rm A COUPLING RpROVi'o For lastlog oprwal d.fzih Norra.l She Ntm Uoltrrr.1 111mr.si..s Approx. .Itd LIrrrlailow/ tsltww i iI• k*Iri6r, N.m6er Wt-E*ti prom prrWflrrf/C91R 4rFMk.Ft ov An vINltrrrr115v r"ail ArpronrttUv.. Meet 1 00 vinain Dm 1.y. LI as addd9iW NA C-1 $10038076 RQG66 ' 7 .41)._ Par addrhonal h9rn91 and 9ppo.va6r s.s 1114 i•Khnicol dols xchon .9Pi Cant.IS,[]uctita iron Fittings wow.anvifstar.cam J ABIMI'2S http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=1970 11/2/2011 Print Page 1 of 1 REDUCING TEE ria vm,irr4 anion orJu„i r.rffir,.e1 Ductile Iron MATERIAL SPECIFICATIONS Didile iron threaded firtin sora UI.&ULC Listed 8 factory Mutual Approved for 5OO psi service. - ----r- -- - Ductile iron per ASTM A536 Class 65.45.12. Dimensions conform to AWE B16.14 A B- Threads are NPT pa-ANSI/ASME B1.20.1. NOTICE[4.011441Witisrsgt Ewe prgrrcr rir,r114/run lhri it rI i.c.*4# •UI.1,4C&FM Kamm Rain" ppa Ther.pbr.,ev4riightrarngwncause damage iv pipe ilrindswldd, fai ddrhonad Lalmgr andapcmych,seo-Iha Iactn dais aarnan. mai wureleakoga Dndlt4rran f+r+ i vId beUgpiened lxae himy beyond lnr,d v9ti,4.0 ro mgra 41,.mss•hi rm REDUCING TEE Far Lktingfappramat°Mails anrf Llmitatbns mica our Mob Slt4 \514>$1 Aral Kona l3eir4p4R gir... IiIlrrrwills yppros- evww.arerdirrN.romarc ne,.cean 4PPROVE� Nominal$ i krlrb4r Amin Wetki I E Wil% Melt`FArni151ar"Salet Rep tarlatiri. C _ _ 4.454 PSJ NM ir.{mail!a(m k.4m117. rid NJ REDUCING TEE H..: ' s.11-101195 (11M Soo- 041y .'y NamIYr1 Sire AEA hem Llniuersrl 141" 6imeniianl ''1dpprar_ 0 }i6rk.ny' 4'41 413 Y NrnN ber rm6er VA_lock prri#ure I 1171 01323 500:.: ? 01331 Sao- all 1.. c.., [mu - 9 014 ` IA• • ' $100044$6 4T3-06 41' 1:' M.S.!, '3d r I r!F.'..; ;.13 0111.1 410 ... --`--- 0.9 15. . . ... I310ua i 4T5.$I `.00 If l.il . '_' . d4 . . ;:15 01333 ii.. • 1. ' , S)xiva 1'. : ::1.3 ' oT131 r_' .. _ • . . 1'':104414 DT553 1;. 1'.' . 01411 -'? G1r'1 u8 1 r 1 %N.1 x' . ::19 DIM Y ' ' . :'3ri ' 4TSd,o ...no . of 1.7 1%t 1,1'; Li .ii 614111 500 i3 11ti. i'. ] !ill I r ;,JJ4o4i DID, - 300 . . - 1!s.1 x 1'., ".i---0T1 i 5E, r 'l ,11 fh1 1'r:,'.... . ':'3 01441 5. .I 13; ' , • . :-:i4 DTd1i 5. 1HY 1..1:, r§u_l,311 DTI T,. 1.4', • . :-;7 VFW ~:1. •. I li a I}S c I 8100013y [11,110 54' 1 4? 41553 ;r' i 1 IA1I:Gc 3h 0001 ii `=. • i. . ." , :.:MiSi _ . _. 1 r 1 t e 9401044345 011.110 • .' - '. '. ' 1c404550 DT&i6 . . ! ' '14 ' 11x9 444401352- 0T531 - - ., • =d::h7U4560 DTSS3 1'.Si134« 810001350 D151] YC 'i 11.31 }1 -14 '24"14. "10044516 Kw `.00 14'. ;:', c •6f:15.1 910001318 01311 5414 '45 1 1.1 '4u ':1 2 r- r , ;:.34 OTdd1 - ... 1'1 x 1 x 1'4' 9100-3$5 0133-0 90 . ' 1 51 '40 -.e 2 e I , 1(.42 2 (4.52 1 y 1 I IN' &40044314 01533 500 1.44 1.87 ''eL , 7 e 2:1:;, , -;:11"I GTII&4 '..41 49.;8 I1 10.1$ 8401001402 01511 904 1,41 134 I.66 3,05 I ?e2,I j '1 :;11 4T665 -.JO2A7 Io • 35.61 34.91 .7.13 0�6 .. Ih.rIF50 34C401.00 01512 504 14.2 1.U5 11.15 Is 9..rori Ma? - :1J9 3461 3633 4445 15Sx1wr1 ' 9100017'4 01313 ' 50 1.45 139 l.94 Y.--1.e5 2Y,s2-o-l; ' - 6T?a'2 .hr "." ". SPF Cant uctito Iron Fittings 1iimw.anuilYtaircom `1�'2! 4 El http://www.anvilintl.com/ProductSearch/PrintProduct.aspx?lid=1966 11/2/2011 Anchoring Systems Fi1`T1 HDI / HDI-L Drop-In Anchor 4.3.5 4.3.4.1 P RODUCTDESCRIPTION The Hilti HDI/HDI-L Drop-In anchor is an internally threaded, flush m ountedexpansion anchor for use in concrete. P roductFeatures HDI • Lip allows accurate flush surface • Anchor, setting tool&Hilti drill bit setting,independent of hole form a matched tolerance depth&ideal for repetitive system to provide reliable fastenings with threaded rods - fastenings of equal length • Below surface setting for easy • Intelligent expansion section patchwork adaptsto the base material& • Allowsforshallow embedment reduces numberof hammer without sacrificing performance b lows up to 50% HDI-L • Easy to read brand&size 14111.‘ . • Lip provides flush installation, identification (red laser print) consistent anchor depth,and easy rod alignment Guide Specifications Expansion Anchors: Expansion anchors shall be flush or shell type which meetthe description in Federal Specification FF-S-325, Group VIII,Type 1, for expansion shield anchors.Anchors to be zinc plated in accordance with ASTM B633, Sc.1, Type III.Anchors shall be Hilti HDI/HDI-L anchors as supplied by Hilti,Inc.,P.O. Box21148, Tulsa, O K 74121. Installation: Shell or flush type anchors to be installed in holes drilled with Hilti carbide tipped drill bits.Anchors shall be installed per manufacturer's recommendations. Approvals/Listings • City of Los Angeles(COLA): Research Report No.23709(HDI Only) • Factory Mutual(FM):Serial No.22765"Sprinkler Hangar Components—Expansion Shields."(HDI and HDI-L) • Conforms to the description in Federal Specification FF-S-325,Group VIII,Type 1 for expansion shield anchors. (HDI and HDI-L) • Underwriters Laboratory(UL),"Pipe Hangers"(3/8"-3/4"diameter)(HDI and HDI-L) • International Conference of Building Officials(ICBG ES):Evaluation Report No.2895(HDI Only) MECHANICAL • Southern Building Code Congress(SBCCI): Report No.9930(HDI Only) PROPERTIES 4.3.5.2 MATERIAL SPECIFICATIONS ksi(fMPa) ksi(MPa) HDI/HDI-L Carbon Steel material meetsthe requirements of AISI 1010M for the 1/4", 3/8"&1/2" 44 (303) 53 (365) HDI Carbon Steel material meetsthe requirements of AISI 12L14 for the 5/8"and 3/4"sizes 60 (415) 78 (540) HDI Stainless Steel material m eetsthe requirements of AISI 303 60 (414) 100 (689) Carbon Steel HDI/HDI-L plated with a dull zinc finish for corrosion protection in accordance with ASTM B633,Sc.1, Type III 4.3.5.3TECHNICAL DATA HDI/HDI-L Specification Table I HDI/HDI-L HDI/HDI-L HDI/HDI-L HDI HDI AnchorSize in. 1/4 3/8 1/2 5/8 3/4 Combined Shear and Details (mm) (6.4) (9.5) (12.7) (15.9) (19.1) Tension Loading db;,: bit diameter' in. 3/8 1/2 5/8 27/32 1 hnom:std.depth of embed. in. 1 18/18 2 29/18 33/18 e: anchor length (mm) (25) (40) (51) (65) (81) N 5/3\ / V \5/3 h,: hole depth d ) + I( d /I <_10 m: useablethread in. 7/18 5/8 11/18 7/8 13/8 Nrec Vrec length (mm) (11) (15) (17) (22) (34) (Ref. Section 4.1.3) Threads per in. 20 16 13 11 10 h: min.base material in. 3 31/8 4 51/8 63/8 thickness (mm) (76) (79) (102) (130) (162) T;861:max.tightening ft lb 4 11 22 37 80 torque (Nm) (5.4) (14.9) (29.8) (50.2) (108.5) 1. For Hilti m atched tolerance carbide tipped drill bits,see section 10.4.1. 134 Hilti Product Technical Guide 2001•Hilti U.S.:1-800-879-8000/www.us.hilti.com•Hilti Canada:1-800-363-4458/www.ca.hilti.com Threaded Accessories Fig. B3205- Threaded Rod (right-hand threads- both ends) (TOLCO Fig.103) ®TOLCO Fig. B3205L- Threaded Rod (right& Iefthand threads) Size Range: 3/8"-16 thru 3"-4 rod X11111111111 Specify Length Material: Steel 11 Function: Recommended for use as a hanger support in hanger assemblies. \1 Rod is threaded on both ends with right hand threads of the length shown.Also TL available with left and right hand threads-specify Fig.B3205Lwhen ordering. llllllll1111111 � A Maximum Temperature: 750°F(399°C) -1 Thread Size Finish: Plain.Contact Cooper B-Line for alternative finishes and materials. Order By: Figure number, rod size,length and finish 01.4. 19 Standard Design Load Thread Size Thread Length TL 650°F(343°C) 750°F(399°C) Part No. A in. (mm) Lbs. (kN) Lbs. (kN) B3205-3/8 x'L' 3/8"-16 21/2' (63.5) 730 (3.25) 572 (2.54) B3205-1/2 x'L' 1/2"-13 21/2' (63.5) 1350 (6.00) 1057 (4.70) B3205-5/8 x'L' 5/8"-11 21/2' (63.5) 2160 (9.61) 1692 (7.52) B3205-3/4 x'L' 3/4"-10 3' (76.2) 3230 (14.37) 2530 (11.25) B3205-7/8 x'L' 7/8"-9 31/2' (88.9) 4480 (19.93) 3508 (15.60) For larger sizes consult full line pipe hanger catalog. —Im- al 03 03 Fig. ATR- All Threaded Rod (TOLL°Fig.99&Fig.100) 0. CD 3 1 --N 1�� Material: Steel 16 thru 1 /2° 6 rod in 10' (3.05m)lengths Mater C8 D c Maximum Temperature: 750°F(399°C) Cl) I Finish: Plain.Contact Cooper B-Line foralternative finishes and materials. 1 ��11111111 Order By: Figure number, rod size,length and finish �`p�711111 71 Note: Fig.99 is cut to length all threaded rod.Fig.100 is full length. Part No. Threads Recommended Load Approx.Wt./100Ft. 4000,0000,41. - &Size Per Inch Lbs. (kN) Lbs. (kg) ATRIA"x`L' 20 240 (1.07) 12 (5.44) ' ATR 3/8"x`L' 16 730 (3.24) 29 (13.15) :, ATR 1/2"x`L' 13 1350 (6.00) 53 (24.04) r rY ATR 3/4"x`L' 11 2160 (9.60) 89 (40.37) ATR3/4"x`L' 10 3230 (14.37) 123 (55.79) ATR7/8"x`L' 9 4480 (19.93) 170 (77.11) For larger sizes consult full line pipe hanger catalog. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. liril. COOPER B-Line Pipe Hangers Fig. 200- "Trimline"Adjustable Band Hanger (Cooper B-Line Fig. B317ONF) ®TOLCO Fig. 200F- "Trimline"Adjustable Band Hanger with Felt Lining (Cooper B-Line Fig. B317ONFF) C)I1S Fig. 200C- "Trimline"Adjustable Band Hanger with Plastic Coated (Cooper B-Line Fig.B317ONFC) LISTED Fig. 200S- "Trimline"Adjustable Band Hanger with Non-Captured Nut Size Range: APPROVED Fig.200 - 1/2"(15mm)thru8"(200mm)pipe Material: Steel,Pre-Galvanized to G90 specifications O�,��;��.�;� Function: For fire sprinkler and other general piping purposes. Knurled - swivel nut design permits hanger adjustment after installation. Features: ' =_ • (1/2"(15mm)thru2"(50mm) Flared edges ease installation forall pipe types and protect CPVC plastic pipe from abrasion. Captured design �� keeps adjusting nut from separating with hanger. Hanger is easily •o \ B installed around pipe. A . , For hanger with non-captured nut order Fig.200S. ' • (21/2" (65mm)thru8"(2oomm))Spring tension on nut holds it securely in ', �,< hanger before installation.Adjusting nut is easily removed. j', Approvals:Underwriters Laboratories listed(1/2"(15mm)thru 8"(200mm)) ,._. Fig.200-1/2.200-3/4 in the USA(UL)and Canada(cUL)for steel and CPVC plastic pipe and Fig.200-1 to 200-2 Fig.200-2112 to 200-8 Factory Mutual Engineering Approved(FM)(3/4"(20mm)thru 8"(200mm)). Conforms to Federal Specifications WW-H-171E&A-A-1192A,Type 10 and Manufacturers Standardization Society ANSI/MSS SP-69&SP-58, Type 10. _,,,i,, Top- Maximum Temperature: 650°F(343°C) Finish: Pre-Galvanized. Stainless Steel _ materials will be supplied with(2)hex nuts in place of a knurl nut. 4, Order By: Figure number and pipe size m Designed to meet or exceed requirements of m FM DS 2-0. • 3 - 0 m H Fig.200 Fig.200C Fig.200F Pipe Size Rod Size A B Approx.Wt./100 _,,,t(�. Part No. in. (mm) in. (mm) in. (mm) Es. (kg) 'mr- 2001/2 1/2" (15) 3/8"-16 31/8" (79.4) 25/8" (66.7) 11 (5.0) 200-3/4 3/4" (20) 3/8"-16 31/8" (79.4) 21/2" (63.5) 11 (5.0) 200-1 1" (25) 3/8"-16 33/8" (85.7) 25/8" (66.7) 12 (5.5) 200-11/4 11/4" (32) 3/8"-16 33/4" (94.0) 27/8" (73.0) 13 (5.9) 200-11/2 11/2" (40) 3/8"-16 37/8" (98.4) 27/8" (73.0) 14 (6.4) 200- 2" (50) 3/8"-16 41/2" (114.3) 3" (76.3) 15 (6.9) 4 200 21/2" (65) 3/8"-16 55/8" (142.9) 41/8" (104.7) 27 (12.3) 200 3" (75) 3/8"-16 57/8" (149.1) 4" (101.6) 29 (13.3) Fig.200S 200-31/2 31/2" (90) 3/8"-16 73/8" (187.3) 51/4" (133.3) 34 (15.6) 200-4 4" (100) 3/8"-16 73/8" (187.3) 5" (127.0) 35 (16.0) 200-5 5" (125) 1/2"-13 91/8" (231.8) 61/4" (158.7) 66 (30.2) 200-1. 6" (150) 1/2"-13 101/8" (257.2) 63/4" (171.4) 73 (33.4) 2 8" (200) 1/2"-13 131/8" (333.4) 83/4" (222.2) 136 (62.3) All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. 20 100 COOPER B-Line