Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
E18-0112_VILLAGE CENTER BLDG 2 ELEV E10_1528137352.pdf
it ell:1 5 9743.0 IN, Qin 06/04/18 ELECTRICAL LEGEND HOUSE PANEL A HOUSE PANEL B PROJECT:VILLAGE CENTER BUILDING 2 ENGINEER: SOH PROJECT:VILLAGE CENTER BUILDING 2 ENGINEER: SOH (NOT ALL SYMBOLS REQUIRED FOR THIS PROJECT) PROJECT#: 18022 VOLTAGE: 120/208V,3P,4W PROJECT#: 18022 VOLTAGE: 120/208V, 3P,4W 0 RECESSED OR SURFACE DOWNLIGHT ABBREVIATIONS MOUNTING: EXISTING MAINS: 200A MLO MOUNTING: EXISTING MAINS: 100A MLO Q-I WALL MOUNTED LIGHT FIXTURE TYPE: EXISTING AIC: 10K TYPE: EXISTING AIC: 10K AC -ABOVE COUNTER _ PHASE PHASE PHASE PHASE qa RECESSED FLUOR.LIGHT FIXTURE AFG AFF -ABOVE FINISHED FLOOR ABOVE FINISHED GRADE DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION _ AHJ -AUTHORITY HAVING JURISDICTION Aa SURFACE FLUOR.LIGHT FIXTURE — AL -ALUMINUM ELEVATOR 9506 100 3 1 2 2 20 90 ELECTRICAL ROOM COMM RM REC 180 _ 20 1 1 2 1 20 1000 _UNIDENTIFIED C u co CV FIXTURE DESIGNATIONS: CU COPPER — a) — UPPER CASE-FIXTURE TYPE EC -ELECTRICAL CONTRACTOR SHUNT TRIP 9506 3 4 90 COMMON ROOM? 180 20 1 3 4 1 20 • 1000 UNIDENTIFIED c a01-0 / LOWER CASE-SWITCH DESIGNATION EM -EMERGENCY CONTRACTOR 9506 5 6 1 20 500 CIRCUIT PUMP COMMON ROOM? 180 20 1 5 6 1 20 500 BOILER PUMP = 0 °6 CO SHADING ON FIXTURE INDICATES EMERG.BATTERY BACKUP GGND -GROUND BOILER RM LTS 500 20 1 7 8 2 30 2500 1ST FLR DRYER PUMP#1 500 20 2 7 8 1 20 100 HEAT TIMER u) u) Lo ti — GFI -GROUND FAULT INTERRUPTER C O i II FLUORESCENT STRIP FIXTURE MC MECHANICAL CONTRACTOR FIRST FLOOR HALL LTS 500 20 1 9 10 2500 _500 9 10 1 20 180 TELEPHONE PANEL O .2-)2 ,7) . I n n I TRACK LIGHT AS NOTED OR SCHEDULED NIC -NOT IN CONTRACT ELECTRICAL ROOM 180 20 1 11 12 2 30 2500 2ND FLR DRYER PUMP#2 500 20 2 11 12 1 20 500 BOILER#1 0 m a U WALL WASHER NL -NIGHT LIGHT — „ 0 'O c .. a NTS NOT TO SCALE SPARE 0 20 1 13 14 2500 500 13 14 1 20 500 BOILER#2 a) 0 x 0 0 . 0 POLE-MOUNTED FIXTURE PC -PLUMBING CONTRACTOR 6TH FLOOR HALL LIGHTS 500 20 1 15 16 2 30 2500 3RD FLR DRYER FIRE ALARM PANEL 100 20 1 15 16 1 20 100 TEKMAR CONTROLLER c-0 < LL _V POST(BOLLARD)FIXTURE REF -REFERENCE — L L N O STEP LIGHT UNO -UNLESSRUNDERGROUND OTHERWISE SPARE 0 20 1 17 18 2500 HOT WATER HEATER 1000 20 1 17 18 2 20 500 WH PUMP#1 N > 2ND FLOOR HALL LIGHTS 500 20 1 19 20 2 30 2500 4TH FLR DRYER PANEL REC NORTH 180 15 1 19 20 500 N �a N oN . ® UTP -UNSHIELDED TWISTED PAIR — in U CEILING OR WALL MOUNTED EXIT LIGHT WP WEATHER PROOF 3RD FLOOR HALL LIGHTS 500 20 1 21 22 2500 ELEVATOR RECALL 180 20 1 21 22 2 20 500 WH PUMP#2 — °o 2 m CO N <il—l'' EMERGENCY BATTERY LIGHTS XFMR TRANSFORMER O Q u) 00 (B +18" -MOUNTING HEIGHT TO CENTERLINE 4TH 5TH FLOOR HALL LIGHTS 500 20 1 23 24 2 30 2500 5TH FLR DRYER ELEVATOR FAN 180 20 1 23 24 500 DUPLEX RECEPTACLE @ 18"UNLESS NOTED OF DEVICE AFF OR AFG 7TH FLOOR HALL LIGHTS 500 20 1 25 26 2500 ELEVATOR LTG 180 20 1 25 26 0 SPACE W - w N Ni ac DOUBLE DUPLEX RECEPTACLE @ 18"UNLESS NOTED NORTH STAIR WELL LTS 1-7 500 20 1 _27 28 2 30 2500 6TH FLR DRYER ELEV EQ ROOM EF 500 20 1 27 28 0 SPACE J°0 o 0FLUSH FLOOR DUPLEX RECEPTACLE FIRE ALARM SYSTEM — (j3 W c0 07 7TH FLR LAUNDRY LTS & REC 380 20 1 29 30 2500 PIT REC & LIGHT 300 20 1 29 30 0 SPACE 3 D To ai ® SPECIAL OUTLET PS NOTED FACP FIRE ALARM CONTROL PANEL 1ST FLR LAUNDRY LTS & REC 380 20 1 31 32 2 30 2500 7TH FLR DRYER 0 31 32 0 �--' ca) _ c DUPLEX RECEPTACLE HALF-SWITCHED @ 18"UNLESS NOTED IIS FIRE ALARM ANNUNCIATOR PANEL — V U O 21VD FLR LAUNDRY LTS& REC 380 20 1 33 34 2500 0 33 34 0 ID POP-UP RECEPTACLE 0 FIRE ALARM PULL STATION — �+ Q Q 6TH FLR LAUNDRY LTS & REC 380 20 1 35 36 2 30 1500 SUB PANEL EXTERIOR LTG 0 35 36 0 ai la TELE-POWER POLE Ell ALARM HORN OR SPEAKER — lc a) c 4TH FLR LAUNDRY LTS & REC 380 20 1 37 38 1500 0 37 38 0 U 2 Q 1- MULTI-OUTLET PLUG STRIP 1=1:1E COMBINATION HORN/STROBE OR SPEAKER/STROBE 5TH FLR LAUNDRY LTS & REC 380 20 1 39 40 1 20 180 ELEVATOR#1 0 39 40 0 i 0 Q 0 CH JUNCTION BOX IN FLOOR,CEILING OR IN WALL •H THERMAL HEAT DETECTOR Q d- 3RD FLR LAUNDRY LTS & REC 380 20 1 41 42 1 20 180 DO NOT TOUCH 0 41 42 0 8 ♦ COMPUTER/TELEPHONE OUTLET IN FLOOR OR WALL •I SMOKE/IONIZATION DETECTOR — I D TELEVISION OUTLET •P PHOTOELECTRIC SMOKE DETECTOR — TELEPHONE BACKBOARD ••H/P HEAT/PHOTOELECTRIC SMOKE DETECTOR LOAD CALCULATION SUMMARY REPLACE EXISTING ELEVATOR WITH NEW. LOAD CALCULATION SUMMARY eillOLD ELEVATOR 70 FLA, NEW ELEVATOR 79 FLA. .+�"��F�•��+•"'''•.,, CONDUIT RUN CONCEALED IN WALL OR ABOVE CEILING S��R DUCT DETECTOR CALCULATED POWER FACTOR: CALCULATED POWER FACTOR: ,�•'`+ck�p0 RSG/,5�f' CIRCUIT HOMERUN QF SPRINKLER SYSTEM FLOW SWITCH ,�� 0 �J — — — CONDUIT RUN BELOW FLOOR OR GRADE WE SPRINKLER SYSTEM TAMPER SWITCH 0 94 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS 0.90 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS : d �� �: ' ] CONDUIT STUB-UP-CAP&MARK ID- STROBE ° O LIGHTING/CONTINUOUS 8400 23 10500 29 LIGHTING/CONTINUOUS 0 0 0 0 - rj LIGHT SWITCH AT 46"UNLESS NOTED eD SMOKE/FIRE DAMPER CONNECTION ��11 • It . SUBSCRIPTS: RECEPTACLES 36980 102 23490 65 RECEPTACLES 4040 11 4040 11 � �' REMOTE INDICATOR LIGHT r ► Cr) 2=2-POLE SWITCH ¢ MECHANICAL 29019 80 36148.8 100 MECHANICAL 7000 23 7250 24 - -0 • 3=3-WAY SWITCH 1 1. % 4C/ i 4=4-WAY SWITCH SECURITY SYSTEM KITCHEN 0 0 0 0 KITCHEN 0 0 0 0 : C�� C(,, �.• M=MOTION-OPERATED SWITCH DC CONTACT DOOR SWITCH IN JAMB OR HINGE TOTAL 74399 206 70139 194 TOTAL 11040 34 11290 35 �` �1 C� .•` TO KEY-OPERATED THERMAL OVERLOAD SWITCH ®KJ INTRUSION MOTION DETECTOR AS SPECIFIED,CORRIDOR/ROOM — ��,',+r]/OI y�� ��* P=SWITCH WITH PILOT LIGHT C OR R ❑D DIMMER SWITCH W/WATTAGE ❑K KEY-OPERATED ACCESS SWITCH E PUSHBUTTON CONTROL STATION I SURVEILLANCE CAMERA HOUSE DISCONNECT O PC PROJECT:PHOTOELECTRIC CELL VILLAGE CENTER BUILDING 2 ENGINEER: SOH 0 DISTRIBUTION EQUIPMENT SYMBOLS TS TIME SWITCH PROJECT#: 18022 VOLTAGE: 120/208V, 3P,4W 0 THERMOSTAT AT 60"UNLESS NOTED DISCONNECT SWITCH MOUNTING: EXISTING MAINS: 200A MLO * Z < eDIVISION 15 EQUIPMENT �I— FUSES TYPE: EXISTING AIC: 10K FOOD SERVICE EQUIPMENT CIRCUIT BREAKER PHASE PHASE O COMMUNICATION SYSTEM ...-.A.-.) CURRENT TRANSFORMER DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION (.9 LLI TRANSFORMER QS 0-I SPEAKER IN CEILING OR WALL AA.N\ ED METER HIGHEST DEMAND 8860 3 1 2 3 1805 ADDITIONAL 15 FLA III-1 VOLUME CONTROL AT 60"UNLESS NOTED ® MAGNETIC MOTOR STARTER 8860 3 4 1805 FOR NEW ELEVATOR OMn 2 1: .0-1 MICROPHONE OUTLET IN FLOOR BOX OR WALL al DISCONNECT SWITCH '� 8860 5 6 1805 & ELEV ACCESSORIES• j LU C CALL-IN SWITCH PANELBOARD OR LOAD CENTER,FLUSH OR SURFACE MOUNTED SPACE 0 7 8 0 SPACE Li j PROGRAM BELL Il SWITCHBOARD,MOTOR CONTROL CENTER OR DISTRIBUTION BOARD SPACE 0 9 10 0 SPACE M ❑I INTERCOM LI TRANSFORMER SPACE 0 11 12 0 SPACE W 0 0CLOCK —III. GROUND SPACE 0 13 14 0 SPACE lO A❑ AMPLIFIER ECIRCUIT BREAKER SPACE 0 15 16 0 SPACE 0MOTOR OUTLET SPACE 0 17 18 0 SPACE li< Q et IIIA AUTOMATIC TRANSFER SWITCH SPACE 0 19 20 0 SPACE ��// SPACE 0 21 22 0 SPACE LJJ LL SPACE 0 23 24 0 SPACEH O SPACE 0 25 26 0 SPACE J SPACE 0 27 28 0 SPACE SPACE 0 29 30 0 SPACE Z O ELECTRICAL SPECIFICATIONS SPACE 0 31 32 0 SPACE 12 U SPACE 0 33 34 0 SPACE UJ SPACE 0 35 36 0 SPACE _ i. General Requirements SPACE 0 37 38 0 (SPACE (_III)SPACE 0 39 40 0 SPACE 0 \�\ 1. SCOPE: Furnish all materials and labor required to execute this work SPACE 0 41 42 0 SPACE O / as indicated on drawing and as specified, as necessary to complete the 11.1 contract. Electrical work shall include, but not limited to,these major LOAD CALCULATION SUMMARY HIGHEST DEMAND ON HOUSE METER IS 26,580 W. WE ARE REPLACING AN I- .i items: EXISTING ELEVATOR AND ADDING 15 AMPS OF POWER TO THE HOUSE PANELS. A. Complete wiring system for new lighting and power as shown, CALCULATED POWER FACTOR: BOTH OF THESE LOADS ARE SHOWN IN LIGHTING/CONTINOUS PER CODE. 0 < including new panelboards, new conduits, new wires, new wiring 1.00 < > CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS NEW WORK IS CLOUDED devices, new control devices, etc. for a complete lighting and ELEVATOR#1 REST IS EXISTING and power system. LIGHTING/CONTINUOUS 31995 89 39994 111 RECEPTACLES 0 0 0 0 79 FLA a. Complete feeder(s) installation as required for new and/or • • © O MECHANICAL 0 0 0 0 electrical apparatus as shown on single line diagram and KITCHEN 0 0 0 0 J drawings. TOTAL 31995 89 39994 111 // N PANEL PANEL 2. Complete provision, installation and connection of lighting fixtures, HOUSE HOUSE > W exit signs and lamps as specified and as shown on drawings. A B 3. Provide grounding and bonding Facilities. ST 3#1, #6CUG) 1-1/4"C 4. Test of entire system and work. l AEC PROJECT #: 18022 5. Operating, Maintenance and identification instructions manuals, if SMOKE DETECTOR AT P• f l TO ELEVATOR 100/3 CIRCUIT BREAKER AT any. ELEVATOR ROOM, ELEVATOR MOTOR ATMACHINE ROOM LOBBY&SHAFT W/aux PANEL WITHIN SIGHT DATE: ISSUE: OF ELEVATOR 8,000 AIC 8,000 AIC 6. PERMITS AND FEES: Obtain and pay for all necessary permits, inspec- CONTACTS. r 05/15/18 PERMIT tions, examinations and fees or charges necessary for execution and completion of electrical work. HEAT DETECTOR LOCATED H• I AT ELEVATOR ROOM & 25 23,25 (4#250 MCM AL, #2 AL G)2"C (3#1, #6 CU G) 1-1/4"C—F' 7. REGULATIONS AND CODES: ELEVATOR SHAFT W/aux ELEVATOR CONTACTS. CONTROLLER I I B-21,23,25 A. Applicable codes: National Electric Code (2014) - OS O. 0, METER#810498 Conform to the prevailing edition and amendments thereto of the 2#14 FROM CONTACTS IN I CAR CAR RECALL HIGHEST DEMAND PER Denver Electrical Codes, pertinent NFPA publications MODULE TO FIRE ALARM IHOLY CROSS IS 26.58 KW and to the requirements of Federal, State or other Cityagencies CONTROL PANEL TO LTG FAN q 9 OR 73.6 AMPS having jurisdiction. MONITOR SHUNT-TRIP (SEE 5 ELEVATOR B-27 NFPA 72) CONTROLLER Drawn By: Checked By: OR BUSSMANN 8. CONDUIT AND WIRE: I SOH AEC 2#14 FROM FIRE ALARM SPOWER © .TO A. CONDUCTOR SIZES AND TYPES: For sizes#1/0 AWG and larger, use CONTROL PANEL HEAT MODULE OR EQUIPMENT copper THW or aluminum XHHW. For sizes#1 AWG and smaller, use only DETECTOR INTIATING EQUAL I ROOM EF 59600 AIC 12,267 AIC •,© ■ copper wire with 600V insulation, types TW, THHN, or THW-stranded in CIRCUIT FOR DEVICES IN THE IF REQUIRED (4#250 MCM AL)2"C ELECTRICAL sizes#8 and larger, solid in sizes#10 and smaller. Control wiring shall be#14, ELEVATOR MACHINE ROOM I. .1 (3)200A FRN-R stranded. Provide a minimum#8 wire per EC drawings. AND SHAFT. 200/3 ELEV. C.B. AT PIT ONE-LINE 1INMDC UTILITY r -i TRANSFORMER & POWER I •, ,I, WP B_29 I PAD MOUNTED /� C THE ELEVATOR SYSTEM INTO RECALL MODE SHALL COMPLY PLANS WITH NFPA I . - - I ELECTRICAL ONE-LINE DIAGRAM ELEVATOR RECALL DIAGRAM L NO SCALE NOTE: PROVIDE SHORT CIRCUIT BRACING TO MEET FAULT CURRENT LEVELS NO SCALE NOTED ON ONE-LINE AS "X AFC", WHERE X IS IN AMPS. SERIES RATED CIRCUIT BREAKER COMBINATIONS ACCEPTABLE; SUBMIT MANUFACTURER'S SERIES RATINGS WITH SHOP DRAWING REVIEW. El • O 1 of 1 ©COPYRIGHT 2014 ARCHITECTURAL ENGINEERING CONSULTANTS, INC.