HomeMy WebLinkAboutB18-0144_REV1 approved documents_1534519901.pdf 75 South Frontage Road Construction
0west, TOWN OF VAIL B18-0144 /Revision 001
TOWN
Vail,CO 81657 Issued: 08/17/2018
TOWN Or VAIL Office:970.479.2139
Inspections:
inspections@vailgov.com
Property Information
Address: 2670 BALD MOUNTAIN RD W(210103403016 )
Unit#:W
Parcel Number: 210103403016
Legal Description: Subdivision:VAILVILLAGE FILING 13 Block:2 Lot:29 UNIT B
Contacts
Contact Type:Applicant
Full Name:Todd Morrisoin
Address: 1120 ChambersAvenue Suite 3C Eagle,CO 81631 Phone: 9703280403
Contact Type:Property Owner
Full Name:EDWARDS,DEBRAJ. &DEAN P.
Address: Phone: None
Contractor
Contractor Type:General
Company: Precision Construction West,Inc
State License#: Phone: 970-328-0403
Projectlnformation
Project Name:Edwards Residence2017
R EV1-The Owneris interested in utilizing Thermasteel structural panels in place of dimensional lumber.
Therefore, KRM has had to modifythefoundation/footing plan and footing rebarschedule.The stamped
Project Description: panel drawingswill be available shortly foryour review. I have historically spoken with CJ about this matter.
PCW has built several Thermasteel structures in Eagle County to date.Adding a garage and master suite
to existing duplex.Also adding plumbing and mechanical.
Fees Paid
Account#:001-0000.31111.00-Building Permit Fee Fee Amount: $2,757.75
Account#:001-0000.31123.00 Building Plan Review Fee Fee Amount: $1,792.54
Account#: 110-0000.31060.00Construction Use Tax Fee Fee Amount: $8,100.00
Account#:001-0000.31111.00-Mechanical Permit Fee Fee Amount: $400.00
Account#:001-0000.31123.00MechanicalPlan Review Fee Fee Amount: $100.00
Account#:001-0000.31111.00-Plumbing Permit Fee Fee Amount: $150.00
Account#:001-0000.31123.00 Plumbing Plan Review Fee Fee Amount: $37.50
Account#: 111-0000.31127.00-Recreation Fee Fee Amount: $189.90
Account#:001-0000.31111.00-Revision Fee Fee Amount: $220.00
Account#:001-0000.31128.00 Will Call Fee(Building Scope) Fee Amount: $5.00
Account#:001-0000.31128.00 Will Call Fee(Mechanical Scope) Fee Amount: $5.00
Account#:001-0000.31128.00 Will Call Fee(PlumbingScope) Fee Amount: $5.00
Total Paid: $13,762.69
Conditions
CONDITIONS UNDER WHICH PERMITS BECOME VOID:
If construction is not begun within 6 months from the date permitwas issued.
If more than 5 months elapses betweeninspections.
If incorrectinformationis given on the application at the time the permitwas issued.
--../1., 4's,
Christopher Jarecki-Town of Vail Building Official
NOTICE:By issuance of this Permitthe applicant agrees to complywith all Titles of the Town of Vail Code and all applicable State and Federal
law.Failureto do so will void this Permit and the applicant shall forfeit all applicablefees.
MAR5020 County Road 154
Glenwood Springs,CO 81601
Geotechnical Engineering I Engineering Geology Phone:(970)945-7988
Materials Testing I Environmental Fax: (970)945-8454
Email: hpkglenwood@kumarusa.com
Office Locations: Denver(HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs, Summit County, Colorado
August 25, 2017
Dean and Deb Edwards
2670 Bald Mountain Road
Vail, CO 81657
deananddebv@ aol.com
Project No. 17-7-603
Subject: Debris Flow Risk Review, Proposed Addition to an Existing Residence, Lot 29,
Block 2, Vail Village, 13th Filing, 2670 Bald Mountain Road, Vail, Colorado
Dear Dean and Deb:
As requested, we have performed a debris flow risk review for the proposed addition to the
existing residence at 2670 Bald Mountain Road, Vail, Colorado. The project location is shown
on Figure 1. The purpose of the review was to assess if the proposed addition could increase the
existing moderate debris flow risk to the residence or other nearby residences, or to public
facilities situated near the residence. The review was performed in accordance with our August
3, 2017 proposal for geologic hazard assessment services. Our review is based on a field
reconnaissance on August 9, 2017, review of published regional debris flow information, aerial
photograph interpretations and our experience in the area. This report summarizes the
information used in our evaluation and presents our findings.
SUMMARY OF FINDINGS
The proposed new addition should not increase the existing moderate debris flow risk to nearby
residences or public facilities. In our opinion, construction of the addition could increase the
debris flow risk to the existing residence at 2670 Bald Mountain Road due to the proposed
changes to the existing site grading and drainage. Proper drainage design, as described in this
report, will help to mitigate some of the additional risk to the existing residence.
PROPOSED DEVELOPMENT
We understand that the proposed construction includes a two-level, wood-frame addition to the
west side of the existing residence. The addition will be structurally attached to the existing
residence, extending approximately 20 feet west, with a footprint of about 400 square feet. The
Dean and Deb Edwards
August 25, 2017
Page 2
addition will consist of a garage lower-level with a slab-on-grade, and a dwelling area on the
upper level. An excavation into the existing slope, west of the residence will be required, and a
permanent retaining wall will be constructed to restrain the excavated slope. The retaining wall
will be up to about 10 feet in height, structurally connected to the addition and parallel the
property line with the adjacent residence to the west.
PROJECT SITE CONDITIONS
The project site is in northeast Vail, north of Interstate 70 and south of Bald Mountain Road, as
shown on Figure 1. The existing residence at the site is accessed via a driveway extending south
and downhill from Bald Mountain Road. The driveway is about 200 feet in length and splits off
an upper driveway leading to the adjacent residence to the west. The driveway initially rises
slightly in elevation from Bald Mountain Road and then descends in elevation about 5 feet to the
garage level of the residence. Both the upper and lower driveway to the residence are bordered
by steep slopes up to the north toward Bald Mountain Road. Residences of similar construction
are located on adjacent lots to the east and west of the subject lot, with the nearest residence
located approximately 50 feet to the west and about 14 feet uphill from the garage level of the
residence at the project site. Residences are also constructed along the north side of Bald
Mountain Road.
DEBRIS FLOW AND FLOOD CHARACTER AND RISK
The subject lot is partially located on the lower portion of a mapped alluvial/debris fan lobe and
in a mapped moderate debris flow hazard zone, Figure 2. The fan originates from a drainage
issuing from the steep hillside north of Bald Mountain Road. The drainage is currently partially
channeled between two houses on the north side of Bald Mountain Road (roughly shown on
Figure 2) with a drainage grate/storm drain system constructed where the channel intersects Bald
Mountain Road.
The alluvial fan was formed by sediment deposition associated with hyperconcentrated flows,
otherwise known as debris floods and debris flows. Floods and debris flow events are
characterized depending on the amount of sediment carried by the flow. Floods, also known as
clear water flows, typically have sediment concentrations of less than 20 percent by volume.
Flows with about 20 and 45 percent sediment content are typically termed debris floods. Flows
H-PMKUMAR
Project No. 17-7-603
Dean and Deb Edwards
August 25, 2017
Page 3
with over 45 percent sediment by volume are called debris flows and may contain large boulders
and organic debris, as well as soil and smaller rock.
Drainage Basin and Fan: The drainage basin up-slope of the alluvial fan at the project site is
very steep with an average slope of about 48 percent along the fan drainage and a basin drainage
area estimated at about 80 acres. The alluvial fan at the base of the slope covers about 20 acres
with a slope of about 20 percent down the fan. The fan developed after the late Pleistocene,
Pinedale-age Gore Creek Valley Glacier retreated up-valley about 16,800 years ago (Benson and
Others, 2005). Alluvial fans grow through sediment deposition on the fan due to repeated
flood/debris flow events. Fan growth on undeveloped alluvial fans generally proceeds through
perching of channels on the fan as sediment is deposited and breaching of the perched channel
during flood events, with the channel migrating to a new path along lower relief portions of the
fan. In this manner the broad, fan shaped geomorphic feature is created. Development on
alluvial fans generally constrains the channel to one location that is maintained through clearing
of debris. This tends to cause additional perching of the maintained channel as flood events
deposit soil and rock in the maintained channel, along with deposition of the material further
down the slope through the channel.
Flow Triggers and Statistical Recurrence Intervals: Historic debris flows and floods in the
Vail area have been triggered by intense thunderstorms or rapid snowmelt, and are considered
extreme events, generally with a long recurrence interval frequently in excess of 100 years.
However, to our knowledge, a fan stratigraphy study has not been completed on the fan at the
subject site, and the statistical recurrence interval of significant flood and debris flow events
can't be estimated with any certainty.
Existing Debris Flow Risk: The official Town of Vail (2000) Debris Flow Hazard Map shows
that a portion of the lot at 2670 Bald Mountain Road, including the residence and the proposed
addition, are in a moderate hazard debris flow zone. The Town of Vail (2000) map is based on
an earlier report by Mears (1984). Mears (1984) describes a moderate debris flow hazard zone
as an area that can experience property damage through flooding, erosion and impact of muddy
water, soil, rock and debris. In general, we concur that the residence and the new proposed
H-P-WU R
Project No. 17-7-603
Dean and Deb Edwards
August 25, 2017
Page 4
addition are in a moderate debris flow hazard zone, as delineated on the Town of Vail Debris
Flow Hazard Map.
Development of residences on the uphill side of Bald Mountain Road resulted in the creation of a
constricted flow channel that connects the upper fan portion of the drainage channel to Bald
Mountain Road. The juncture of the channel and Bald Mountain Road occurs approximately 130
feet uphill, and about 45 degrees west of north from the subject residence as roughly shown on
Figure 2. The juncture of the channel and Bald Mountain Road is about 25 feet higher in
elevation than the lower driveway level of the existing residence. A stormwater drainage
structure, consisting of an inlet grate,joined to a stormwater drainage pipe, was observed where
the drainage meets the roadway. The design capacity of the stormwater structure is unknown,
but based on our observations, it is our opinion that if the drainage structure is maintained in an
unobstructed manner, the system will be capable of handling low to moderate volume clear water
and low volume debris floods. Floods of extended duration or carrying significant debris, such
as debris flows during extreme events, may block and/or exceed the capacity of the grate and
stormwater system, and subsequently top the roadway surface. In such an event, the flow would
likely travel east down the roadway as well as continue south across the roadway and down the
steep slopes above the upper and lower driveways. In the site's current configuration, based on
the lower driveway grade, the flow could then impact the existing residence before flowing
around the residence to the west and continuing downhill south of the residence. In our opinion,
the scenario outlined above constitutes the known, moderate debris flow hazard to the existing
structure.
Potential Debris Flow Risk: The construction of the addition, with the planned cut into the
adjacent slope to the west and construction of the retaining wall, will effectively block the
existing flow path of any flood or debris flow event that reaches the residence, and prevent the
flow from passing to the west of the residence and continuing downhill to dissipate. The
relatively steep slope up to the adjacent residence on the west should constrain the blocked flow
and prevent impact to the adjacent residence. Although not increasing the risk for debris flow
hazards to adjacent structures or public facilities, it is our opinion that construction of the
addition will increase the debris flow hazard risk to the existing residence at 2670 Bald Mountain
Road. The owner should be aware of the increased risk and need to mitigate the risk. We
H-vKUMAR
Project No. 17-7-603
Dean and Deb Edwards
August 25, 2017
Page 5
understand that relocating the addition and/or further cutting into the slope to allow for passage
of debris flows are not preferred or viable options. As another means to mitigate some of the
potential for increased risk to the existing structure, a culvert type drainage structure could be
constructed adjacent to and under the planned addition in a fairly straight alignment, to allow a
flow path for debris flood or flow during an extreme event. The culvert structure should be large
enough to allow for periodic cleaning and maintenance and should daylight downhill from the
residence and addition in such a manner as to not impact adjacent properties. A minimum two-
foot diameter concrete pipe should allow for periodic maintenance and allow an unobstructed
flow path.
A review of preliminary project plans indicates that a drop inlet is planned in the lower driveway
to accommodate stormwater drainage from the driveway. The drop inlet will be connected to a
buried 12-inch rigid pipe that will pass under a portion of the retaining wall before effecting a
near right angle turn to pass along the west foundation line of the addition, daylighting downhill
from the residence. Although reportedly sufficient to accommodate normal stormwater drainage
from the driveway area, it has been our experience that the small diameter pipe and sharp turn
system is prone to blockage and as such, is not recommended to accommodate a possible debris
flow or flood event.
A debris flow analysis was beyond the scope of this review and flow calculations regarding
maximum anticipated flows were not used in the preparation of this report and the
recommendations therein. If the owner is concerned about the risk of damage from debris flow
events, further analysis, such as Flow 2D modeling to develop appropriate mitigation
recommendations could be made.
LIMITATIONS
This study was conducted according to generally accepted engineering geology principles and
practices in this area, at this time. We make no warranty either express or implied. The
information presented in this report is based on our field observations, aerial photograph
interpretations, the proposed development discussed in this report and our experience in the area.
This report has been prepared exclusively for our client to evaluate if the proposed addition
could increase the existing moderate debris flow and flood risk to the existing residence and
H-P�KUMAR
Project No. 17-7-603
Dean and Deb Edwards
August 25, 2017
Page 6
other facilities on the alluvial fan in the vicinity of Lot 29. We are not responsible for technical
interpretations by others of our information.
If you have any questions or need further assistance, please call our office.
Sincerely,
H-P KUMAAR
V `
, 1 :�
James A. Parker, E.,P. P . }• 1 S4 p'l3 e2 Y�8
:YY
\ a
\ 1
Reviewed by: '�t�1r�r.P/25 ��c%'/"
Steven L. Pawlak,P.E.
JAP/kac
Attachments: Figure 1 - Vicinity Map
Figure 2 - Site Map
cc: Michael A. Hazard, A.I.A. —Michael Hazard Associates— mha(cii ail.net
REFERENCES
Benson, L. and Others, 2005,New Data for Late Pleistocene Pinedale Alpine Glaciations from
Southwestern Colorado: Quaternary Science Review V.25, p. 49-65.
Mears, A.I., 1984, Debris-Flow and Debris-Avalanche Hazard Analysis: Prepared for the Town
of Vail, Colorado (November, 1984).
River Restoration.org, 2011, Vail 2010 Flood Assessment: Prepared for the Town of Vail,
Colorado (January 27, 2011).
Town of Vail, 2000, Official Debris Flow Hazard Map, Town of Vail: Prepared by the Town of
Vail, Vail, Colorado (Adopted by the Town Council on October 17, 2000).
H-PWUMAR
Project No. 17-7-603
j )
I`
e
1
< - I CL
''.-411.- ti 1 <
U Z
cr
a.
I
e
0 I
t
N
I ?
I I
A
1
�1 {
LL
0
,, 1
s
.
, W
k —J
Q
U
N
Z + O M
ti,!._ ~ O
H (D
,r O I
Z
N
Q7
Li
w
F-p
QO
�O
WJ
O�
O }
mace
W m p
ai.,Z
—C3 o
X p 0]
Or
Ff �
{ >.y F-
y .ism'-�` � ^ -�._
'AN Z U i ry W
rn,-,\ , .r ,eirt - , .r..;, I. i - - ..:' -',' I=
f,r),Vi ‘.i"-• L...1 tt)
S / t ®��a `% ® A
r,i ... Her j. y .
/
la i
c. -.31t 6r .
.,. ,.. .: ..... , s ,,_
, ,.. .., ., .
.. .. . .„. :..,,..
...,...„ .t.,,, it -
4+ r
' ' .� . titL.--,:,.'
'% O i., i�we., �.
�`R :.:,,, 'S
`1 -..l �''` -ate , _� O
/ - f� 0 6 I „ til
1.. 1 a 4 "
1. i r.g •,.''t' ce- ...,,s 16 •
/ 'JP,r- .
1t 'I _ i. .1 •meq}
§t
.
At, _i rte- , LV
7#4
\ _
s F F ,.
.. S.
' -1- 1 I iii
kr 4j' r1i�
J
a
U
O
H L0
O I
Z
°I1111
PERMIT FEE RECEIPT
TOWN OF VAIL Case # B18-0144
Date Printed: 05/23/2018
TOWN OF VAIL - FEES RECEIPT
Permit Summary
Case Number: B18-0144 Status: Approved
Permit Number: Date Started: 04/17/2018
Permit Type: Construction Subc ases Duplex
Lot Number: 29
Property: 2670 BALD MOUNTAIN RDW(210103403016 W)(210103403016)
Contacts
Contact Type: Applicant
Company Name: Precision Construction West, Inc
Full Name: Todd Morrisoin
Address: 1120 Chambers Avenue Suite 3C Eagle, CO 81631
Email: todd@pcwbuilds.com
Contact Type: Property Owner
Full Name: EDWARDS,DEBRA J. & DEAN P.
Address:
Permit Fees
Fee Information Account Amount
Permit Fee 001-0000.31111.00 $3,307.75
Construction Tax 110-0000.31060.00 $8,100.00
Recreation Fee 111-0000.31127.00 $189.90
Will Call Fee 001-0000.31128.00 $15.00
Payment Information Date Paid Payment Type Amount
Construction Tax 05/23/2018 Check $8,100.00
Paid By:Dean&Debra Edwards-Notes:110-Dean&Debra Edwards
Will Call Fee 05/23/2018 Check $15.00
Paid By:Dean&Debra Edwards-Notes:110-Dean&Debra Edwards
Permit Fee 05/23/2018 Check $3,307.75
Paid By:Dean&Debra Edwards-Notes:110-Dean&Debra Edwards
Recreation Fee 05/23/2018 Check $189.90
Paid By:Dean&Debra Edwards-Notes:110-Dean&Debra Edwards
FEE TOTAL $11,612.65
AMOUNT PAID $11,612.65
BALANCE DUE $0.00
75 South Frontage Road West,Vail,Colorado 81657 05/23/2018-9:02:42 AM-Generated by:do ouc h
1/1
Department of Community Development
75 South Frontage Road
TOWN OF VA11 ' Vail, Co 81657
Tel: 970-479-2139
www.vailgov.com
Geologic Hazard Acknowledgement
Date: April 20, 2018
Legal Description: Vail Village Filing 13, Block 2, Lot 29, Unit B
Physical Address: 2670 Bald Mountain Rd., Vail, CO 81657
Property Owner. Debra J. Edwards and Dean P. Edwards
Project No: B18-0144
The undersigned has/have read the site specific geologic investigation, prepared by James A. Parker. P.E.,
P.G., HP Kumar, dated August 25, 2017 on this_ day of , 2018 . I/We understand from the
conclusions of the Geological Hazard Report that the proposed structure is located in a Moderate Hazard
Debris Flow hazard zone, and there is a risk of a debris flow reaching the structure and causing damage.
INVe are prepared to accept these facts and risks, and I/We request that the Town of Vail Community
Development Department issue a building permit for the propo ed improvements.
4.,s1 „v.._ • corda
Owner Signre Owner Signature
P t,. rc.IL
Owner Name(Print) Owner Name (Print)
ALENA SHERASH
State of Colorado ) Notary Public
State of Colorado
)ss. Notary ID#20174007184
County of Eagle 1 My Commission Expires 02-15-2021
The foregoing instrument was acknowledged before me this O 3 day of I p R/L ,20 a by
Debg a, J Ca"u.kc:,mS c nnc ca/1 P c°d u,cud,s'
Witness my hand and official seal. qqf
My Commission expires: /5--DZ C
Notary Public
1.1...•'loll A
mAR5020 County Road 154
Glenwood Springs, CO 81601
Geotechnical Engineering I Engineering Geology Phone: (970)945-7988
Materials Testing I Environmental Fax: (970)945-8454
Email: hpkglenwood@kumarusa.com
Office Locations: Denver(HQ), Parker, Colorado Springs, Fort Collins, Glenwood Springs,Summit County, Colorado
June 29, 2018
Precision Construction West
Attn: Todd Morrison
P.O. Box 3145
Eagle, Colorado 81631
todd@pcwbuilds.com
Project No. 17-7-603.01
Subject: Observation of Excavation, Proposed Garage Addition, Edwards Residence,
Lot 29B, Block 2, Filing 13, Vail Village, 2670 Bald Mountain Road West, Vail,
Colorado
Dear Todd:
As requested, a representative of H-P/Kumar observed the excavation at the subject site on June
20, 2018 to evaluate the soils exposed for foundation support. The findings of our observations
and recommendations are presented in this report. The services are supplemental to our proposal
for professional engineering services to Dean and Deb Edwards, dated August 3, 2017. We
previously reviewed the debris flow risk at the site for the planned addition and submitted our
findings to the Edwards in a report dated August 25, 2017, under our Project No. 17-7-603.
The garage will be attached to the west side of the residence and be two story construction.
Ground floor will be slab-on-grade. The addition has been designed to be supported on spread
footings assuming an allowable soil bearing pressure of 2,000 psf. The existing residence is
apparently founded on shallow spread footings.
At the time of our site visit, the foundation excavation which was essentially complete had been
cut in two levels from about 6 to 10 feet below the adjacent ground surface. The excavation
subgrade was at the same elevation as the existing residence spread footing bearing elevation
adjacent the building. The soils exposed in the bottom of the excavation consisted of medium
dense, silty sand and gravel with cobbles and boulders. The results of a gradation analysis
performed on a sample of the sand and gravel soils (minus 3 inch fraction) obtained from the site
are presented on Figure 1. No free water was encountered in the excavation and the soils were
slightly moist to moist.
Considering the conditions exposed in the excavation and the nature of the proposed
construction, spread footings placed on the undisturbed natural granular soil designed for an
allowable bearing pressure of 2,000 psf can be used for support of the proposed garage. There
could be some differential settlement with respect to the existing structure which should
considered in the design. Footings should be a minimum width of 16 inches for continuous walls
Precision Construction West
June 29, 2018
Page 2
and 2 feet for columns. Loose and disturbed soils in footing areas should be removed and the
bearing level extended down to the undisturbed natural soils and the subgrade compacted.
Exterior footings should be provided with adequate soil cover above their bearing elevations for
frost protection. Continuous foundation walls should be reinforced top and bottom to span local
anomalies such as by assuming an unsupported length of at least 10 feet. Foundation walls
acting as retaining structures should also be designed to resist a lateral earth pressure based on an
equivalent fluid unit weight of at least 50 pcf for on-site soil, excluding topsoil and oversized
(plus 6 inch)rocks as backfill. A perimeter foundation drain should be provided to prevent
temporary buildup of hydrostatic pressure behind the foundation walls acting as retaining
structures and prevent wetting of the building interior. Structural fill placed within floor slab
areas can consist of the on-site sand and gravel soils compacted to at least 95% of standard
Proctor density (SPD) at a moisture content near optimum. Backfill placed around the structure
should be compacted to at least 90% SPD and the surface graded to prevent ponding within at
least 10 feet of the building.
The recommendations submitted in this letter are based on our observation of the soils exposed
within the foundation excavation and do not include subsurface exploration to evaluate the
subsurface conditions within the loaded depth of foundation influence. This study is based on
the assumption that soils beneath the footings have equal or better support than those exposed.
The risk of foundation movement may be greater than indicated in this report because of possible
variations in the subsurface conditions. In order to reveal the nature and extent of variations in
the subsurface conditions below the excavation, drilling would be required. It is possible the
data obtained by subsurface exploration could change the recommendations contained in this
letter. Our services do not include determining the presence, prevention or possibility of mold or
other biological contaminants (MOBC) developing in the future. If the client is concerned about
MOBC, then a professional in this special field of practice should be consulted.
If you have any questions or need further assistance, please call our office.
Sincerely,
H-P-KUM ' - �
J'a?an. .h4►
i3 3.
yA
ii Pr
David A. Young, P'00,104....-7_z
rry 1.216 �I"I r
DAY/kac '4- 1••• eaImo`CI NC
attachment Figure 1, agimIt st Results
cc: Micheal Hazard, AIA (mha54@comcast.net)
KRM Consultants—Nicholas Ripp (nicholas@krmconsultants.com.)
H-P``KUMAR Project No. 17-7-603.01
HYDROMETER ANALYSIS SIEVE ANALYSIS
, TIME READINGS U.S. STANDARD SERIES CLEAR SQUARE OPENINGS
24 MRS 7 MRS
100 MI MI -.MIN 19MIN 4MIN 1MIN 0. 100 50 40 30 16 10 . 4 3 - I 1 5"6. 6.0
90 - 1 1 IN 10
1 I
ao 1 I --� 20
70 1 1 Nor T 3a
1
60 1 1 --, 1
40 W
50 __
was I 50 S
�i� _
40 ■■ 1 60
30 �' -- 70
•
e'1M111111531311311=11=1M1e11Mi INIIIMIIIIIMMII eIIIIMa•IIIITR1111=11!•e1•== IIIMEe1_IINIMIl•
20
I I I 50
_ I _ 1 I
10 • t 1
I _ 4.
1111 i 90
0 I I I I I I I I I I I III! 1 — 11 I _I III- I 1 I I I I I 1 l I I 1 II I 100
.001 .002 .005 .009 .019 .037 .075 .150 .300 I .600 1.16 12.36 4.75 9.5 19 35.1 76.2 127 200
425 2.0 152
I . DIAMETER OF PARTICLES IN MILLIMETERS
I
CLAY TO SILT SAND GRAVEL
FINE MEDIUM COARSE FINE COARSE COBBLES
GRAVEL 51 % SAND 30 % SILT AND CLAY 19 %
LIQUID LIMIT PLASTICITY INDEX
SAMPLE OF: Silty Sandy Gravel FROM: Bottom of Garage Addition Excavation
14
0
E
2
S
f
I
41
E. These test results apply only to the
W samples which were tested. The
S testing report shall not be reproduced,
• except In full, without the written
0 approval of Kumar& Associates, Inc.
Sieve analysis testing is performed In
Ei accordance with ASTM D422, ASTM C136
.� and/or ASTM 01140.
41 17-7-603.01 H-PtiKU1V AR GRADATION TEST RESULT Fig. 1
75 South Frontage Road Construction
0West, TOWN OF VAIL B18-0144
TOWN
Vail,CO 81657 Issued: 05/24/2018
TOWN Or VAIL Office:970.479.2139
Inspection Line:970.479.2149
Property Information
Address: 2670 BALD MOUNTAIN RDW(210103403016 W)(210103403016 )
Unit#:W
Parcel Number: 210103403016
Legal Description: Subdivision:VAILVILLAGE FILING 13 Block:2 Lot:29 UNITB
Contacts
Contact Type:Applicant
Full Name:Todd Morrisoin
Address: 1120 ChambersAvenue Suite 3C Eagle,CO 81631 Phone: 9703280403
Contact Type:Property Owner
Full Name:EDWARDS,DEBRAJ.&DEAN P.
Address: Phone: None
Contractor
Contractor Type:General
Company: Precision Construction West,Inc
State License#: Phone: 970-328-0403
Projectlnformation
Project Name:Edwards Residence 2017
Project Description: Adding a garage and master suite to existing duplex.Also adding plumbing and mechanical.
Fees Paid
Account#:001-0000.31111.00-Building Permit Fee Fee Amount: $2,757.75
Account#:001-0000.31123.00 Building Plan Review Fee Fee Amount: $1,792.54
Account#: 110-0000.31060.00Construction Use Tax Fee Fee Amount: $8,100.00
Account#:001-0000.31111.00-Mechanical Permit Fee Fee Amount: $400.00
Account#:001-0000.31123.00 MechanicalPlan Review Fee Fee Amount: $100.00
Account#:001-0000.31111.00-Plumbing Permit Fee Fee Amount: $150.00
Account#:001-0000.31123.00 Plumbing Plan Review Fee Fee Amount: $37.50
Account#: 111-0000.31127.00-Recreation Fee Fee Amount: $189.90
Account#:001-0000.31128.00 Will Call Fee(Building Scope) Fee Amount: $5.00
Account#:001-0000.31128.00 Will Call Fee(Mechanical Scope) Fee Amount: $5.00
Account#:001-0000.31128.00 Will Call Fee(Plumbing Scope) Fee Amount: $5.00
Total Paid: $13,542.69
Conditions
CONDITIONS UNDER WHICH PERMITS BECOME VOID:
If construction is not begun within 6 months from the date permitwas issued.
If more than 5 months elapses betweeninspections.
If incorrectinformationis given on the application at the time the permitwas issued.
Christopher Jarecki-Town of Vail Building Official
NOTICE:By issuance of this Permitthe applicant agrees to complywith all Titles of the Town of Vail Code and all applicable State and Federal
law.Failure to do so will void this Permit and the applicant shallforfeit all applicablefees.