Loading...
HomeMy WebLinkAboutF18-0054_approved documents_1536100666.pdf 75 South Frontage Road Fire-Construction Permit 0West, TOWN OF VAIL F18-0054 TOWN Vail,CO 81657 Issued: 09/04/2018 TOWN Or VAIL Office:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 551 N FRONTAGE RDW(210106302013) (210106302013 ) Unit#: Parcel Number: 210106302013 Legal Description: RED SANDSTONE ELEMENTARY SCHOOL Contacts Contact Type:Applicant Full Name:Jeremy Craig Address: 10864 W CoCo Place Littleton,CO 80127 Phone: 9703933242 Contact Type:Property Owner Full Name:EAGLE COUNTY SCHOOL DISTRICT RE-50J Address: Phone: None Contractor Contractor Type:Fire Protection Company: Assurance Fire Systems, Inc. State License#: 18-S-06113 Phone: 303-798-4448 Projecllnformation Project Name:Red Sandstone Elementary 2017 Project Description: Red Sandstone Elementary School-Install new fire sprinkler system per NFPA 13 Fees Paid Account#:001-0000.31111.00-Fire Suppression Permit Fee Fee Amount: $2,954.81 Account#:001-0000.31123.00 Fire Suppression Review Fee Fee Amount: $432.00 Total Paid: $3,386.81 Conditions Issued By:Town of V ailFireand Emergency Services Department NOTICE:By issuance of this Permitthe applicant agrees to complyto all Titles of the Town of Vail Code and all applicable State and Federal law.Failureto do so will void this Permit and the applicant shallforfeit all applicablefees. HYDRAULIC CALCULATIONS i "� � : \ IRF,5 0 , • . , Assurance Fire Systems Assurance Fire Systems 10864 Coco PI. Littleton,CO 80127 303-798-4448 Job Name : 18034 Red Sandstone ES Drawing : FP4 Location : 551 N Frontage Rd West,Vail, CO 81657 Remote Area : 1 Contract : 18034 Data File : 18034 Red Sandstone ES Area 1.WXF Date/Time : 07/09/2018 -6:0 PM Computer Programs by Hydratec Inc. Revision: 50.53.5 Assurance Fire Systems Page 1 18034 Red Sandstone ES Date 7/9/2018 HYDRAULIC CALCULATIONS for Project name: Red Sandstone ES Location: 551 N Frontage Rd West,Vail, CO 81657 Drawing no: FP4 Date: 7/9/2018 Design Remote area number: 1 Remote area location: Classroom 212 Occupancy classification: Light Hazard Density: 0.1 - Gpm/SqFt Area of application: 1030 -SqFt Tyler J. Shaw, CET Coverage per sprinkler: 400 -SqFt NICET Lvl III #118820 Type of sprinklers calculated: ECLH Pendent No. of sprinklers calculated: 5 In-rack demand: -- GPM Hose streams: 100 - GPM Total water required(including hose streams): 311.214 - GPM @ 68.039- Psi Type of system: Wet Volume of dry or preaction system: -- Gal Water supply information Date: 9/21/2017 Location: On Site Source: ERWSD Name of contractor: Assurance Fire Systems Address: 10864 Coco PI./ / Littleton,CO 80127 Phone number: 303-798-4448 Name of designer: T. Shaw Authority having jurisdiction: Vail Fire Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Revision: 50.53.5 Water Supply Curve C Assurance Fire Systems Page 2 18034 Red Sandstone ES Date 7/9/2018 City Water Supply: Demand: Cl -Static Pressure : 86.4 D1 - Elevation : 8.480 C2 - Residual Pressure: 85.5 D2 -System Flow : 211.214 C2 - Residual Flow : 1678 D2 -System Pressure : 68.039 Hose ( Demand ) : 100 D3 -System Demand : 311.214 Safety Margin : 18.322 150 140 : 130 ' P 120 R 110 E 100 S 90 Cl • C2 ci0 S 80 D 70 D2 R 60 3 E 50 40 30 20 10 o D1 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N ^ 1.85 ) Computer Programs by Hydratec Inc. Revision: 50.53.5 Flow Diagram Assurance Fire Systems Page 3 18034 Red Sandstone ES Date 7/9/2018 40.1 80.7 211.2 211.2 211.2 101 F 102 F 103 F 104 F 105<- J1 F TOR2- BOR2 BKFL BAS TEST 1' 40.1 123.4 211.2 211.2 211.2 I 40.1 40.61 106F 103 T I 80.7 42.61 107F 104 87.9 105-> 108 43.6 87.9 109<- 110<- 111<- 108 1' 43.6 I 43.6 44.21 112 F 111 Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary Assurance Fire Systems Page 4 18034 Red Sandstone ES Date 7/9/2018 Fitting Legend Abbrev. Name 1/2 3/4 1 1% 1% 2 21/2 3 3'% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zcb Colt C200 Vert Butt Fitting generates a Fixed Loss Based on Flow Fve Vic Flex%K14 AH2 ULtST (-1)=31 in (-2)=36 in (-3)=48 in (-4)=60 in (-5)=72 in 12.5 19.5 24.5 21 41 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with*. The fittings marked with a *show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a*will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 Pressure/ Flow Summary- STANDARD Assurance Fire Systems Page 5 18034 Red Sandstone ES Date 7/9/2018 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 101 119.58 11.2 12.8 na 40.07 0.1 400 12.8 102 119.92 24.19 na 103 119.92 24.87 na 104 119.92 27.29 na 105 119.92 31.86 na J1 109.17 48.03 na TOR2 109.17 51.72 na BOR2 105.12 57.99 na BKFL 105.12 58.01 na BASE 100.0 67.12 na TEST 100.0 68.04 na 100.0 106 119.58 11.2 13.17 na 40.64 0.1 400 12.8 107 119.58 11.2 14.49 na 42.64 0.1 400 12.8 108 119.92 31.74 na 109 119.58 11.2 15.17 na 43.63 0.1 400 12.8 110 119.92 28.53 na 111 119.92 29.3 na 112 119.58 11.2 15.6 na 44.23 0.1 400 12.8 The maximum velocity is 16.87 and it occurs in the pipe between nodes 104 and 105 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen-Williams Assurance Fire Systems Page 6 18034 Red Sandstone ES Date 7/9/2018 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf *EQUIVALENT K'S *REMOTE HEAD TO SUPPLY 101 119.58 11.20 40.07 1 T 5.84 0.010 120 12.800 to Fve-2 19.5 28.617 -0.147 102 119.92 40.07 1.083 0.0 28.627 0.4029 11.535 Vel = 13.96 102 119.92 0.0 1.5 E 5.645 10.720 120 24.188 to 0.0 5.645 0.0 103 119.92 40.07 1.728 0.0 16.365 0.0414 0.677 Vel = 5.48 103 119.92 40.65 1.5 0.0 16.000 120 24.865 to 0.0 0.0 0.0 104 119.92 80.72 1.728 0.0 16.000 0.1512 2.420 Vel = 11.04 104 119.92 42.63 1.5 T 11.29 2.500 120 27.285 to 0.0 11.290 0.0 105 119.92 123.35 1.728 0.0 13.790 0.3315 4.571 Vel = 16.87 105 119.92 87.86 3 5E 52.472 240.430 120 31.856 to T 22.488 74.960 4.656 J1 109.17 211.21 3.334 0.0 315.390 0.0365 11.518 Vel = 7.76 J1 109.17 0.0 3 4E 41.977 59.030 120 48.030 to 0.0 41.977 0.0 TOR2 109.17 211.21 3.334 0.0 101.007 0.0365 3.689 Vel = 7.76 TOR2 109.17 0.0 3 T 22.488 4.040 120 51.719 to B 14.992 37.480 4.754 * * Fixed Loss= 3 BOR2 105.12 211.21 3.334 Fsp 0.0 41.520 0.0365 1.517 Vel = 7.76 BOR2 105.12 0.0 4 0.0 1.500 120 57.990 to 0.0 0.0 0.0 BKFL 105.12 211.21 4.31 0.0 1.500 0.0100 0.015 Vel = 4.64 BKFL 105.12 0.0 4 E 18.536 5.120 140 58.005 to Zcb 0.0 40.779 8.755 ** Fixed Loss= 6.537 BASE 100 211.21 4.31 B 22.243 45.899 0.0079 0.361 Vel = 4.64 BASE 100 0.0 4 E 14.534 45.000 140 67.121 to T 29.067 46.508 0.0 TEST 100 211.21 4.1 G 2.907 91.508 0.0100 0.918 Vel = 5.13 100.00 Qa = 100.00 TEST 311.21 68.039 K Factor= 37.73 *NEW PATH 106 119.58 11.20 40.64 1 T 5.84 0.010 120 13.170 to Fve-2 19.5 28.617 -0.147 103 119.92 40.64 1.083 0.0 28.627 0.4137 11.842 Vel = 14.15 0.0 103 40.64 24.865 K Factor= 8.15 *NEW PATH 107 119.58 11.20 42.64 1 T 5.84 0.010 120 14.493 to Fve-2 19.5 28.617 -0.147 104 119.92 42.64 1.083 0.0 28.627 0.4520 12.939 Vel = 14.85 0.0 104 42.64 27.285 K Factor= 8.16 *NEW PATH Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen-Williams Assurance Fire Systems Page 7 18034 Red Sandstone ES Date 7/9/2018 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 105 119.92 -87.86 3 0.0 16.000 120 31.856 to 0.0 0.0 0.0 108 119.92 -87.86 3.334 0.0 16.000 -0.0072 -0.115 Vel = 3.23 0.0 108 -87.86 31.741 K Factor= -15.59 *NEW PATH 109 119.58 11.20 43.63 1 T 5.84 0.010 120 15.173 to Fve-2 19.5 28.617 -0.147 110 119.92 43.63 1.083 0.0 28.627 0.4715 13.499 Vel = 15.20 110 119.92 0.0 1.5 0.0 16.000 120 28.525 to 0.0 0.0 0.0 111 119.92 43.63 1.728 0.0 16.000 0.0485 0.776 Vel = 5.97 111 119.92 44.23 1.5 T 11.29 2.500 120 29.3 01 to 0.0 11.290 0.0 108 119.92 87.86 1.728 0.0 13.790 0.1769 2.440 Vel = 12.02 0.0 108 87.86 31.741 K Factor= 15.59 *NEW PATH 112 119.58 11.20 44.23 1 T 5.84 0.010 120 15.598 to Fve-2 19.5 28.617 -0.147 111 119.92 44.23 1.083 0.0 28.627 0.4838 13.850 Vel = 15.40 0.0 111 44.23 29.301 K Factor= 8.17 Computer Programs by Hydratec Inc. Revision: 50.53.5 HYDRAULIC CALCULATIONS i "� � : \ IRF,5 0 , • . , Assurance Fire Systems Assurance Fire Systems 10864 Coco PI. Littleton,CO 80127 303-798-4448 Job Name : 18034 Red Sandstone ES Drawing : FP5 Location : 551 N Frontage Rd West,Vail, CO 81657 Remote Area : 2 Contract : 18034 Data File : 18034 Red Sandstone ES Area 2.WXF Date/Time : 07/09/2018 -6:2 PM Computer Programs by Hydratec Inc. Revision: 50.53.5 Assurance Fire Systems Page 1 18034 Red Sandstone ES Date 7/9/2018 HYDRAULIC CALCULATIONS for Project name: Red Sandstone ES Location: 551 N Frontage Rd West,Vail, CO 81657 Drawing no: FP5 Date: 7/9/2018 Design Remote area number: 2 Remote area location: Gym Occupancy classification: Light Hazard Density: 0.10 - Gpm/SqFt Area of application: 1575 -SqFt Coverage per sprinkler: 225 -SqFt Tyler J Shaw, CET Type of sprinklers calculated: QR Upright NICET Lvl III #118820 No. of sprinklers calculated: 7 In-rack demand: -- GPM Hose streams: 100 - GPM Total water required(including hose streams): 259.216 -GPM @ 46.4132- Psi Type of system: Wet Volume of dry or preaction system: -- Gal Water supply information Date: 9/21/2018 Location: On Site Source: ERWSD Name of contractor: Assurance Fire Systems Address: 10864 Coco PI./ / Littleton,CO 80127 Phone number: 303-798-4448 Name of designer: T. Shaw Authority having jurisdiction: Vail Fire Notes: (Include peaking information or gridded systems here.) System has been automatically peaked. See peaking summary sheet. Computer Programs by Hydratec Inc. Revision: 50.53.5 Water Supply Curve C Assurance Fire Systems Page 2 18034 Red Sandstone ES Date 7/9/2018 City Water Supply: Demand: Cl -Static Pressure : 86.4 D1 - Elevation : 10.576 C2 - Residual Pressure: 85.5 D2 -System Flow : 159.216 C2 - Residual Flow : 1678 D2 -System Pressure : 46.413 Hose ( Demand ) : 100 D3 -System Demand : 259.216 Safety Margin : 39.958 150 140 130 p 120 R 110 E 100 S 90 •C1 C2 0 S 80 U 70 R 60 E 50 D2 40 1 3 30 20 10 6 D1 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N ^ 1.85 ) Computer Programs by Hydratec Inc. Revision: 50.53.5 Flow Diagram Assurance Fire Systems Page 3 18034 Red Sandstone ES Date 7/9/2018 18.5 41.1 47.9 24.3 24.3 159.2 159.2 159.2 201 F 202 F 203 F 204 F 205<- 206 F 207 F 208<- 209 F 210 F 211<- J1 <- TOR,- BOR-2- BK FL- BASE TEST 41.1 71.1 24.3 24.3 159.2 159.2 159.2 159.2 4 49.2 88.1 134.9 201 F 212<- 213<- 214<- 215<- 216<- 217<- 210 26.5 49.2 111.3 29.9 29.9 15.9 3 9 204 218- 219-* 220- 221<- 222F 223E 224<- 215 T 29.9 7 39 39 I 71.1 I 23.2 23.2 205F 225F 226<- 216 23.2 I 47.9 I 111.3 I 23.6 23.61 206F 227F 228F 217 23.6 Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary Assurance Fire Systems Page 4 18034 Red Sandstone ES Date 7/9/2018 Fitting Legend Abbrev. Name '/2 3/4 1 1% 1% 2 21/2 3 3'% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zcb Colt C200 Vert Butt Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with*. The fittings marked with a *show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a*will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 Pressure/ Flow Summary- STANDARD Assurance Fire Systems Page 5 18034 Red Sandstone ES Date 7/9/2018 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 201 124.42 5.6 16.14 na 22.5 0.1 225 7.0 202 124.42 5.6 16.29 na 22.6 0.1 225 7.0 203 124.42 16.99 na 204 123.42 17.96 na 205 123.42 18.16 na 206 123.42 18.25 na 207 123.42 18.26 na 208 124.42 18.03 na 209 124.42 19.66 na 210 123.42 20.29 na 211 123.42 21.47 na J1 109.17 29.85 na TOR2 109.17 32.04 na BOR2 105.12 37.69 na BKFL 105.12 37.7 na BASE 100.0 45.87 na TEST 100.0 46.41 na 100.0 212 124.42 5.6 16.15 na 22.51 0.1 225 7.0 213 124.42 5.6 16.44 na 22.71 0.1 225 7.0 214 124.42 18.73 na 215 123.42 19.9 na 216 123.42 20.01 na 217 123.42 20.16 na 218 123.42 17.92 na 219 124.42 17.19 na 220 124.42 5.6 16.8 na 22.95 0.1 225 7.0 221 124.42 5.6 16.77 na 22.94 0.1 225 7.0 222 124.42 5.6 16.89 na 23.01 0.1 225 7.0 223 124.42 18.96 na 224 123.42 19.88 na 225 124.42 17.91 na 226 124.42 19.39 na 227 124.42 18.0 na 228 124.42 19.54 na The maximum velocity is 6.73 and it occurs in the pipe between nodes 213 and 214 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen-Williams Assurance Fire Systems Page 6 18034 Red Sandstone ES Date 7/9/2018 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf *EQUIVALENT K'S *REMOTE HEAD TO SUPPLY 201 124.42 5.60 18.54 1.5 0.0 15.000 120 16.143 to 0.0 0.0 0.0 202 124.42 18.54 1.728 0.0 15.000 0.0099 0.149 Vel = 2.54 202 124.42 5.60 22.60 1.5 T 11.29 4.730 120 16.292 to 0.0 11.290 0.0 203 124.42 41.14 1.728 0.0 16.020 0.0435 0.697 Vel = 5.63 203 124.42 0.0 1.5 T 11.29 1.000 120 16.989 to 0.0 11.290 0.433 204 123.42 41.14 1.728 0.0 12.290 0.0434 0.534 Vel = 5.63 204 123.42 29.94 2.5 0.0 15.000 120 17.956 to 0.0 0.0 0.0 205 123.42 71.08 2.705 0.0 15.000 0.0135 0.202 Vel = 3.97 205 123.42 -23.16 2.5 0.0 13.580 120 18.158 to 0.0 0.0 0.0 206 123.42 47.92 2.705 0.0 13.580 0.0066 0.089 Vel = 2.68 206 123.42 -23.59 2.5 0.0 8.000 120 18.247 to 0.0 0.0 0.0 207 123.42 24.33 2.705 0.0 8.000 0.0019 0.015 Vel = 1.36 207 123.42 0.0 1.5 T 11.29 1.000 120 18.262 to 0.0 11.290 -0.433 208 124.42 24.33 1.728 0.0 12.290 0.0164 0.202 Vel = 3.33 208 124.42 0.0 1.5 2T 22.58 76.270 120 18.031 to 0.0 22.580 0.0 209 124.42 24.33 1.728 0.0 98.850 0.0164 1.625 Vel = 3.33 209 124.42 0.0 1.5 T 11.29 1.000 120 19.656 to 0.0 11.290 0.433 210 123.42 24.33 1.728 0.0 12.290 0.0165 0.203 Vel = 3.33 210 123.42 134.89 3 T 22.488 31.800 120 20.292 to 0.0 22.488 0.0 211 123.42 159.22 3.334 0.0 54.288 0.0216 1.175 Vel = 5.85 211 123.42 0.0 3 4E 41.977 22.840 120 21.467 to T 22.488 79.457 6.172 J1 109.17 159.22 3.334 B 14.992 102.297 0.0217 2.215 Vel = 5.85 J1 109.17 0.0 3 4E 41.977 59.030 120 29.854 to 0.0 41.977 0.0 TOR2 109.17 159.22 3.334 0.0 101.007 0.0217 2.187 Vel = 5.85 TOR2 109.17 0.0 3 T 22.488 4.040 120 32.041 to B 14.992 37.480 4.754 ** Fixed Loss= 3 BOR2 105.12 159.22 3.334 Fsp 0.0 41.520 0.0217 0.899 Vel = 5.85 BOR2 105.12 0.0 4 0.0 1.500 120 37.694 to 0.0 0.0 0.0 BKFL 105.12 159.22 4.31 0.0 1.500 0.0060 0.009 Vel = 3.50 BKFL 105.12 0.0 4 E 18.536 5.120 140 37.703 to Zcb 0.0 40.779 7.952 * * Fixed Loss= 5.735 BASE 100 159.22 4.31 B 22.243 45.899 0.0047 0.214 Vel = 3.50 BASE 100 0.0 4 E 14.534 45.000 140 45.869 to T 29.067 46.508 0.0 TEST 100 159.22 4.1 G 2.907 91.508 0.0059 0.544 Vel = 3.87 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen-Williams Assurance Fire Systems Page 7 18034 Red Sandstone ES Date 7/9/2018 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 100.00 Qa= 100.00 TEST 259.22 46.413 K Factor= 38.05 *NEW PATH 201 124.42 3.96 1.5 0.0 15.000 120 16.143 to 0.0 0.0 0.0 212 124.42 3.96 1.728 0.0 15.000 0.0006 0.009 Vel = 0.54 212 124.42 5.60 22.51 1.5 0.0 15.000 120 16.152 to 0.0 0.0 0.0 213 124.42 26.47 1.728 0.0 15.000 0.0192 0.288 Vel = 3.62 213 124.42 5.60 22.70 1.5 T 11.29 26.540 120 16.440 to 0.0 11.290 0.0 214 124.42 49.17 1.728 0.0 37.830 0.0605 2.288 Vel = 6.73 214 124.42 0.0 1.5 T 11.29 1.000 120 18.728 to 0.0 11.290 0.433 215 123.42 49.17 1.728 0.0 12.290 0.0605 0.743 Vel = 6.73 215 123.42 38.96 3 0.0 15.000 120 19.904 to 0.0 0.0 0.0 216 123.42 88.13 3.334 0.0 15.000 0.0073 0.109 Vel = 3.24 216 123.42 23.17 3 0.0 13.580 120 20.013 to 0.0 0.0 0.0 217 123.42 111.3 3.334 0.0 13.580 0.0111 0.151 Vel = 4.09 217 123.42 23.59 3 0.0 8.000 120 20.164 to 0.0 0.0 0.0 210 123.42 134.89 3.334 0.0 8.000 0.0160 0.128 Vel = 4.96 0.0 210 134.89 20.292 K Factor= 29.94 *NEW PATH 204 123.42 -29.94 2.5 0.0 15.000 120 17.956 to 0.0 0.0 0.0 218 123.42 -29.94 2.705 0.0 15.000 -0.0027 -0.041 Vel = 1.67 218 123.42 0.0 1.5 T 11.29 1.000 120 17.915 to 0.0 11.290 -0.433 219 124.42 -29.94 1.728 0.0 12.290 -0.0241 -0.296 Vel = 4.10 219 124.42 0.0 1.5 T 11.29 4.730 120 17.186 to 0.0 11.290 0.0 220 124.42 -29.94 1.728 0.0 16.020 -0.0242 -0.387 Vel = 4.10 220 124.42 5.60 22.95 1.5 0.0 15.000 120 16.799 to 0.0 0.0 0.0 221 124.42 -6.99 1.728 0.0 15.000 -0.0017 -0.025 Vel = 0.96 221 124.42 5.60 22.94 1.5 0.0 15.000 120 16.774 to 0.0 0.0 0.0 222 124.42 15.95 1.728 0.0 15.000 0.0075 0.113 Vel = 2.18 222 124.42 5.60 23.01 1.5 T 11.29 41.540 120 16.887 to 0.0 11.290 0.0 223 124.42 38.96 1.728 0.0 52.830 0.0393 2.077 Vel = 5.33 223 124.42 0.0 1.5 T 11.29 1.000 120 18.964 to 0.0 11.290 0.433 224 123.42 38.96 1.728 0.0 12.290 0.0393 0.483 Vel = 5.33 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen-Williams Assurance Fire Systems Page 8 18034 Red Sandstone ES Date 7/9/2018 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 224 123.42 0.0 3 0.0 15.000 120 19.880 to 0.0 0.0 0.0 215 123.42 38.96 3.334 0.0 15.000 0.0016 0.024 Vel = 1.43 0.0 215 38.96 19.904 K Factor= 8.73 *NEW PATH 205 123.42 23.16 1.5 T 11.29 1.000 120 18.158 to 0.0 11.290 -0.433 225 124.42 23.16 1.728 0.0 12.290 0.0151 0.185 Vel = 3.17 225 124.42 0.0 1.5 2T 22.58 76.270 120 17.910 to 0.0 22.580 0.0 226 124.42 23.16 1.728 0.0 98.850 0.0150 1.485 Vel = 3.17 226 124.42 0.0 1.5 T 11.29 1.000 120 19.395 to 0.0 11.290 0.433 216 123.42 23.16 1.728 0.0 12.290 0.0151 0.185 Vel = 3.17 0.0 216 23.16 20.013 K Factor= 5.18 *NEW PATH 206 123.42 23.59 1.5 T 11.29 1.000 120 18.247 to 0.0 11.290 -0.433 227 124.42 23.59 1.728 0.0 12.290 0.0155 0.191 Vel = 3.23 227 124.42 0.0 1.5 2T 22.58 76.270 120 18.005 to 0.0 22.580 0.0 228 124.42 23.59 1.728 0.0 98.850 0.0155 1.535 Vel = 3.23 228 124.42 0.0 1.5 T 11.29 1.000 120 19.540 to 0.0 11.290 0.433 217 123.42 23.59 1.728 0.0 12.290 0.0155 0.191 Vel = 3.23 0.0 217 23.59 20.164 K Factor= 5.25 Computer Programs by Hydratec Inc. Revision: 50.53.5 AutoPeaking Summary Assurance Fire Systems Page 9 18034 Red Sandstone ES Date 7/9/2018 Auto Peaking Summary- List of Pipes for Area Calculated Left Right Side Side From To Length From To Length 202 203 4.730 213 214 26.540 219 220 4.730 222 223 41.540 Flow Safety Pressure Required Margin Differential Area Calculated I 259.216 39.958 0.000 Right 15.000 I 259.276 40.224 -0.265 Typical Distance Between Heads = 15.000 Split Point Used in Worst Area Peaked = 201 Computer Programs by Hydratec Inc. Revision: 50.53.5 HYDRAULIC CALCULATIONS i "� � : \ IRF,5 0 , • . , Assurance Fire Systems Assurance Fire Systems 10864 Coco PI. Littleton,CO 80127 303-798-4448 Job Name : 18034 Red Sandstone ES Drawing : FP3 Location : 551 N Frontage Rd West,Vail, CO 81657 Remote Area : 3 Contract : 18034 Data File : 18034 Red Sandstone ES Area 3.WXF Date/Time : 07/09/2018 -6:13 PM Computer Programs by Hydratec Inc. Revision: 50.53.5 Assurance Fire Systems Page 1 18034 Red Sandstone ES Date 7/9/2018 HYDRAULIC CALCULATIONS for Project name: Red Sandstone ES Location: 551 N Frontage Rd West,Vail, CO 81657 Drawing no: FP3 Date: 7/9/2018 Design Remote area number: 3 Remote area location: Kitchen Occupancy classification: Ordinary Hazard Group 1 Density: 0.15 - Gpm/SqFt Area of application: 970 - SqFt Tyler J Shaw, CET Coverage per sprinkler: 130-SqFt NICET Lvl III #118820 Type of sprinklers calculated: QR Pendent No. of sprinklers calculated: 13 In-rack demand: -- GPM Hose streams: 250 - GPM Total water required(including hose streams): 495.095 -GPM @ 34.493- Psi Type of system: Wet Volume of dry or preaction system: -- Gal Water supply information Date: 9/21/2017 Location: On Site Source: ERWSD Name of contractor: Assurance Fire Systems Address: 10864 Coco PI./ / Littleton,CO 80127 Phone number: 303-798-4448 Name of designer: T. Shaw Authority having jurisdiction: Vail Fire Notes: (Include peaking information or gridded systems here.) Computer Programs by Hydratec Inc. Revision: 50.53.5 Water Supply Curve C Assurance Fire Systems Page 2 18034 Red Sandstone ES Date 7/9/2018 City Water Supply: Demand: Cl -Static Pressure : 86.4 D1 - Elevation : 3.681 C2 - Residual Pressure: 85.5 D2 -System Flow : 245.095 C2 - Residual Flow : 1678 D2 -System Pressure : 34.493 Hose ( Demand ) : 250 D3 -System Demand : 495.095 Safety Margin : 51.813 150 140 130 ' P 120 R 110 E 100 S 90 ci C1 • C2 0 S 80 U 70 R 60 E 50 • 40 D2 30 1 0 D3 20 10 200 400 600 800 1000 1200 1400 1600 1800 FLOW( N ^ 1.85 ) Computer Programs by Hydratec Inc. Revision: 50.53.5 Flow Diagram Assurance Fire Systems Page 3 18034 Red Sandstone ES Date 7/9/2018 19.9 56.8 150.8 245.1 245.1 245.1 301<- 302 4- 303 4- 304 4- 305 4- 306 4- 3074- TORO BORA- BOP2 SKF-- BASE TEST 19.9 95.1 206.9 245.1 245.1 245.1 3 6.9 303- 308 19.8 3 8.3 309 4- 310 4- 311 4- 304 1' 19.8 I 19.8 18.51 312 4- 311 18.4 3 6.9 3134- 3144- 3154- 308 1' 18.4 I 18.4 18.51 316 4- 315 18.5 3 7 317 4- 318 4- 319 4- 305 1' 18.5. t I 18.51 37 150.8 18.51 I 320 4- 319 I 18.7 I 321<- 322<- 305 18.7 18.6 3 7.31 323 4- 324 4- 325 4- 306 1' 18.6 I 18.61 37.3 18.71 I 326 4- 325 I 18.9 I 327 4- 328 4- 306 18.9' I 206.9 19 329 4- 330 4- 307 19 19.1 331 4- 332 4- 307 19.1 Computer Programs by Hydratec Inc. Revision: 50.53.5 Fittings Used Summary Assurance Fire Systems Page 4 18034 Red Sandstone ES Date 7/9/2018 Fitting Legend Abbrev. Name 1/2 3/4 1 1% 1% 2 21/2 3 3'% 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 10 0 12 9 10 12 19 21 0 0 0 0 0 E NFPA 13 90'Standard Elbow 1 2 2 3 4 5 6 7 8 10 12 14 18 22 27 35 40 45 50 61 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 1 2 2 3 4 5 6 7 8 10 11 13 T NFPA 13 90'Flow thru Tee 3 4 5 6 8 10 12 15 17 20 25 30 35 50 60 71 81 91 101 121 Zcb Colt C200 Vert Butt Fitting generates a Fixed Loss Based on Flow Fve Vic Flex%K14 AH2 ULtST (-1)=31 in (-2)=36 in (-3)=48 in (-4)=60 in (-5)=72 in 12.5 19.5 24.5 21 41 Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch Note: Fitting Legend provides equivalent pipe lengths for fittings types of various diameters. Equivalent lengths shown are standard for actual diameters of Sched 40 pipe and CFactors of 120 except as noted with*. The fittings marked with a *show equivalent lengths values supplied by manufacturers based on specific pipe diameters and CFactors and they require no adjustment. All values for fittings not marked with a*will be adjusted in the calculation for CFactors of other than 120 and diameters other than Sched 40 per NFPA. Computer Programs by Hydratec Inc. Revision: 50.53.5 Pressure/ Flow Summary- STANDARD Assurance Fire Systems Page 5 18034 Red Sandstone ES Date 7/9/2018 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Req. 301 108.5 5.6 12.68 na 19.94 0.15 128 7.0 302 108.83 13.69 na 303 108.83 13.9 na 304 108.83 13.92 na 305 108.83 14.02 na 306 108.83 14.25 na 307 108.83 14.54 na TORI 108.83 17.93 na BOR1 105.12 23.94 na BOR2 105.12 23.96 na BKFL 105.12 23.98 na BASE 100.0 33.28 na TEST 100.0 34.49 na 250.0 308 108.83 13.9 na 309 108.5 5.6 12.52 na 19.81 0.15 77 7.0 310 108.83 13.41 na 311 108.83 13.46 na 312 108.5 5.6 10.86 na 18.45 0.15 59 7.0 313 108.5 5.6 10.82 na 18.42 0.15 65 7.0 314 108.83 13.41 na 315 108.83 13.47 na 316 108.5 5.6 10.87 na 18.46 0.15 65 7.0 317 108.5 5.6 10.88 na 18.47 0.15 112 7.0 318 108.83 13.49 na 319 108.83 13.57 na 320 108.5 5.6 10.94 na 18.52 0.15 109 7.0 321 108.5 5.6 11.16 na 18.71 0.15 115 7.0 322 108.83 13.83 na 323 108.5 5.6 11.06 na 18.62 0.15 112 7.0 324 108.83 13.71 na 325 108.83 13.79 na 326 108.5 5.6 11.13 na 18.68 0.15 96 7.0 3 27 108.5 5.6 11.3 5 na 18.86 0.15 96 7.0 328 108.83 14.07 na 329 108.5 5.6 11.57 na 19.05 0.15 127 7.0 330 108.83 14.34 na 331 108.5 5.6 11.63 na 19.1 0.15 99 7.0 332 108.83 14.41 na The maximum velocity is 9.01 and it occurs in the pipe between nodes 307 and TORI Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen-Williams Assurance Fire Systems Page 6 18034 Red Sandstone ES Date 7/9/2018 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf *EQUIVALENT K'S *REMOTE HEAD TO SUPPLY 301 108.5 5.60 19.94 1 E 2.336 2.240 120 12.677 to T 5.84 8.176 -0.143 302 108.83 19.94 1.083 0.0 10.416 0.1108 1.154 Vel = 6.94 302 108.83 0.0 1.5 T 11.29 7.650 120 13.688 to 0.0 11.290 0.0 303 108.83 19.94 1.728 0.0 18.940 0.0114 0.216 Vel = 2.73 303 108.83 36.88 3 0.0 3.810 120 13.904 to 0.0 0.0 0.0 304 108.83 56.82 3.334 0.0 3.810 0.0031 0.012 Vel = 2.09 304 108.83 38.26 3 0.0 12.000 120 13.916 to 0.0 0.0 0.0 305 108.83 95.08 3.334 0.0 12.000 0.0083 0.100 Vel = 3.49 305 108.83 55.70 3 0.0 12.000 120 14.016 to 0.0 0.0 0.0 306 108.83 150.78 3.334 0.0 12.000 0.0196 0.235 Vel = 5.54 306 108.83 56.17 3 0.0 8.170 120 14.251 to 0.0 0.0 0.0 307 108.83 206.95 3.334 0.0 8.170 0.0353 0.288 Vel = 7.61 307 108.83 38.15 3 4E 41.977 28.470 120 14.539 to 0.0 41.977 0.0 TORI 108.83 245.1 3.334 0.0 70.447 0.0481 3.388 Vel = 9.01 TORI 108.83 0.0 3 E 10.494 3.710 120 17.927 to B 14.992 25.486 4.607 ** Fixed Loss = 3 BOR1 105.12 245.1 3.334 Fsp 0.0 29.196 0.0481 1.404 Vel = 9.01 BOR1 105.12 0.0 4 0.0 1.500 120 23.938 to 0.0 0.0 0.0 BOR2 105.12 245.1 4.31 0.0 1.500 0.0133 0.020 Vel= 5.39 BOR2 105.12 0.0 4 0.0 1.500 120 23.958 to 0.0 0.0 0.0 BKFL 105.12 245.1 4.31 0.0 1.500 0.0140 0.021 Vel = 5.39 BKFL 105.12 0.0 4 E 18.536 5.120 140 23.979 to Zcb 0.0 40.779 8.830 * * Fixed Loss= 6.613 BASE 100 245.1 4.31 B 22.243 45.899 0.0103 0.475 Vel = 5.39 BASE 100 0.0 4 E 14.534 45.000 140 33.284 to T 29.067 46.508 0.0 TEST 100 245.1 4.1 G 2.907 91.508 0.0132 1.209 Vel = 5.96 250.00 Qa= 250.00 TEST 495.10 34.493 K Factor= 84.30 *NEW PATH 303 108.83 -36.88 3 0.0 4.190 120 13.904 to 0.0 0.0 0.0 308 108.83 -36.88 3.334 0.0 4.190 -0.0014 -0.006 Vel = 1.36 0.0 308 -36.88 13.898 K Factor= -9.89 *NEW PATH 309 108.5 5.60 19.81 1 E 2.336 1.250 120 12.516 to T 5.84 8.176 -0.143 310 108.83 19.81 1.083 0.0 9.426 0.1096 1.033 Vel = 6.90 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen-Williams Assurance Fire Systems Page 7 18034 Red Sandstone ES Date 7/9/2018 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 310 108.83 0.0 1.5 0.0 4.950 120 13.406 to 0.0 0.0 0.0 311 108.83 19.81 1.728 0.0 4.950 0.0111 0.055 Vel = 2.71 311 108.83 18.45 1.5 T 11.29 0.680 120 13.461 to 0.0 11.290 0.0 304 108.83 38.26 1.728 0.0 11.970 0.0380 0.455 Vel = 5.23 0.0 304 38.26 13.916 K Factor= 10.26 *NEW PATH 312 108.5 5.60 18.45 1 T 5.84 0.010 120 10.856 to Fve-2 19.5 28.617 -0.143 311 108.83 18.45 1.083 0.0 28.627 0.0960 2.748 Vel = 6.43 0.0 311 18.45 13.461 K Factor= 5.03 *NEW PATH 313 108.5 5.60 18.42 1 T 5.84 0.010 120 10.818 to Fve-2 19.5 28.617 -0.143 314 108.83 18.42 1.083 0.0 28.627 0.0957 2.739 Vel = 6.42 314 108.83 0.0 1.5 0.0 6.000 120 13.414 to 0.0 0.0 0.0 315 108.83 18.42 1.728 0.0 6.000 0.0098 0.059 Vel = 2.52 315 108.83 18.46 1.5 T 11.29 0.680 120 13.473 to 0.0 11.290 0.0 308 108.83 36.88 1.728 0.0 11.970 0.0355 0.425 Vel = 5.05 0.0 308 36.88 13.898 K Factor= 9.89 *NEW PATH 316 108.5 5.60 18.46 1 T 5.84 0.010 120 10.866 to Fve-2 19.5 28.617 -0.143 315 108.83 18.46 1.083 0.0 28.627 0.0961 2.750 Vel = 6.43 0.0 315 18.46 13.473 K Factor= 5.03 *NEW PATH 317 108.5 5.60 18.47 1 T 5.84 0.010 120 10.877 to Fve-2 19.5 28.617 -0.143 318 108.83 18.47 1.083 0.0 28.627 0.0962 2.753 Vel = 6.43 318 108.83 0.0 1.5 0.0 8.000 120 13.487 to 0.0 0.0 0.0 319 108.83 18.47 1.728 0.0 8.000 0.0099 0.079 Vel = 2.53 319 108.83 18.52 1.5 T 11.29 1.320 120 13.566 to 0.0 11.290 0.0 305 108.83 36.99 1.728 0.0 12.610 0.0357 0.450 Vel = 5.06 0.0 305 36.99 14.016 K Factor= 9.88 *NEW PATH 320 108.5 5.60 18.52 1 T 5.84 0.010 120 10.942 to Fve-2 19.5 28.617 -0.143 319 108.83 18.52 1.083 0.0 28.627 0.0967 2.767 Vel = 6.45 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen-Williams Assurance Fire Systems Page 8 18034 Red Sandstone ES Date 7/9/2018 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf 0.0 319 18.52 13.566 K Factor= 5.03 *NEW PATH 321 108.5 5.60 18.71 1 T 5.84 0.010 120 11.159 to Fve-2 19.5 28.617 -0.143 322 108.83 18.71 1.083 0.0 28.627 0.0985 2.819 Vel = 6.52 322 108.83 0.0 1.5 T 11.29 6.680 120 13.835 to 0.0 11.290 0.0 305 108.83 18.71 1.728 0.0 17.970 0.0101 0.181 Vel = 2.56 0.0 305 18.71 14.016 K Factor= 5.00 *NEW PATH 323 108.5 5.60 18.62 1 T 5.84 0.010 120 11.061 to Fve-2 19.5 28.617 -0.143 324 108.83 18.62 1.083 0.0 28.627 0.0977 2.796 Vel = 6.49 324 108.83 0.0 1.5 0.0 8.000 120 13.714 to 0.0 0.0 0.0 325 108.83 18.62 1.728 0.0 8.000 0.0100 0.080 Vel = 2.55 325 108.83 18.68 1.5 T 11.29 1.320 120 13.794 to 0.0 11.290 0.0 306 108.83 37.3 1.728 0.0 12.610 0.0362 0.457 Vel = 5.10 0.0 306 37.30 14.251 K Factor= 9.88 *NEW PATH 326 108.5 5.60 18.68 1 T 5.84 0.010 120 11.126 to Fve-2 19.5 28.617 -0.143 325 108.83 18.68 1.083 0.0 28.627 0.0982 2.811 Vel = 6.51 0.0 325 18.68 13.794 K Factor= 5.03 *NEW PATH 327 108.5 5.60 18.86 1 T 5.84 0.010 120 11.347 to Fve-2 19.5 28.617 -0.143 328 108.83 18.86 1.083 0.0 28.627 0.1000 2.863 Vel = 6.57 328 108.83 0.0 1.5 T 11.29 6.680 120 14.067 to 0.0 11.290 0.0 306 108.83 18.86 1.728 0.0 17.970 0.0102 0.184 Vel = 2.58 0.0 306 18.86 14.251 K Factor= 5.00 *NEW PATH 329 108.5 5.60 19.05 1 T 5.84 0.010 120 11.572 to Fve-2 19.5 28.617 -0.143 330 108.83 19.05 1.083 0.0 28.627 0.1018 2.915 Vel = 6.63 330 108.83 0.0 1.5 T 11.29 7.320 120 14.344 to 0.0 11.290 0.0 307 108.83 19.05 1.728 0.0 18.610 0.0105 0.195 Vel = 2.61 0.0 307 19.05 14.539 K Factor= 5.00 Computer Programs by Hydratec Inc. Revision: 50.53.5 Final Calculations : Hazen-Williams Assurance Fire Systems Page 9 18034 Red Sandstone ES Date 7/9/2018 Node1 Elev1 K Qa Nom Fitting Pipe CFact Pt to or Ftngs Pe ******* Notes ****** Node2 Elev2 Fact Qt Act Eqiv Len Total Pf/Ft Pf *NEW PATH 331 108.5 5.60 19.10 1 T 5.84 0.010 120 11.628 to Fve-2 19.5 28.617 -0.143 332 108.83 19.1 1.083 0.0 28.627 0.1023 2.928 Vel = 6.65 33 2 108.83 0.0 1.5 T 11.29 0.680 120 14.413 to 0.0 11.290 0.0 307 108.83 19.1 1.728 0.0 11.970 0.0105 0.126 Vel = 2.61 0.0 307 19.10 14.539 K Factor= 5.01 Computer Programs by Hydratec Inc. Revision: 50.53.5 Memorandum Alpine Eng.Inc. To: Deborah Shaner(Fire Protection Engineer), shanerls@comcast.net Mike Vaughan(Vail Fire Chief),mvaughan@vailgov.com Greg Hall(TOV), ghall@vailgov.com Chad Salli(TOV),csalli@vailgov.com Greg Macik(TAB),greg@tabassociates.com Tug Birk (ERWSD),dbirk@erwsd.org From: Glenn Palmer AEI,970-926-3373; Palmer@alpinecivil.com Date: September 22,2017 Re: Red Sandstone Elementary School Fire Flow Test Attendees: ERWSD (water department),Alpine Engineering(Glenn,Matt,and Rosa) On Thursday, September 21, 2017, a Fire Hydrant Flow Test was performed at Red Sandstone Elementary. Fire hydrant #050 located at the upper west playground area was the measuring hydrant and the#052 located at the west end of the bus loop was the flowing hydrant. Elevations, measured pressures, and calculated flow are presented below. Q = 29.83cd2J where: Q= flow in GPM c = orifice coefficient, 0.9 d= diameter orifice opening, 2.5" p=pitot pressure in psi Typical water line depth= 7 ft, typical FH nozzle height above ground= 3 ft Fire Hydrant#050—measuring FH Approximate elevation of nozzle(added 3 ft from ground for nozzle height) = 8240 ± Static Pressure= 101 psi Residual Pressure while flowing FH 052 at 1678 GPM=99 psi Fire Hydrant#052—flowing FH Approximate elevation of nozzle(added 3 ft from ground for nozzle height)= 8200± Static Pressure= 120 psi Pitot pressure= 100 psi and Q = 1678 GPM Did not ask ERWSD for HWL at Tank 4 because we thought we had plenty of pressure and flow; therefore, felt it was not needed. FH Measured Measured Measured Suggested Suggested Static Residual Flow Static* Residual* #050 101 psi 99 psi 96-101 psi 95 psi #052 120 psi 1678 GPM 115-125 psi *Reduce pressures by 4 psi for mid tank Required fire flow for a 4 level parking garage = 1250 GPM (per Deborah Shaner email 9/20/17-2015 IFC Appendix B; 50%reduction for sprinklered building) Glenn Palmer,PE: Alpine Engineering Inc. lki H 022 �:� 7°Z . 0 -E.; FH 028 ,8 PVC @g ps9 5 ©1.00% C�;`F� „DIP �I BP 003 AiI� O .' -' (R3`)\- 6 FH 024 �� 22, g'PV TANK 4 DIS 7_,:t 'O�BA �G �� g0@15.• 39% FH 0'0 tL S o PV 006 HWL 8478 I '=o2.1. Gg 6 �� o HI 86 CAP 1.0MG �� FL 20 Imo' @ p\P LO 62 L `t' 60 15'.10„ `•7 161.79'-8"PVC@7.669 /A BP 002 ` �,� FH 018 FH 030 S_--� 50'-80%G @0.50% VC 10 11 12 SUC 8"DIt 10'8\P @0.5 _pis �� 6"DIP pVG @,.65% FH 026 R S U B D V I S I O\ O LIST 7, In/ #1 56HP-- M g1.9'2- Z'S„ 14 #2 50HP 300GPM Ig 60 8"PVC@14.45% O #3 100HP 600GPM ©, 3, 8' ` 4 BLOCK 2, VA I L CIA T O ATC H 12'DIP •6g9 VC 199.43'-8"p V i5.51'-8"PVC @5.24% 12"DIP ©4.80% �S 17.22'-8"PVC I`�20.38' 8"P VC ©3'-6,,, @1 3.82% •6V /C3'0 T p,5©8. gg"PVC 141©8-8"PVC 247.30'-8»PVC ©5.81% 99C 336')S,\ /1 " 6.129 @6.688 C 1---/ D^ 111 /9. o 11111. -411111, 23".04 14.00% �Q � @ ,.�/ FH 03 5 8 Pic / � 3 65' 6"DIP 9b______-7--<,@_ 6 FH 034 ,1 8 / ar.a- 0 At'/ 1 N � pop 'V 058 *OFF* 95—6'DIP rJ LL_I co o (/ 4 1,1 iiiii CO A SANDY :a 111Th. :Fr a t ��Alir IN POTATO : ',„ , , �,„„„„„,„ ,, .,rat ww, ..,-,,,. , ',. ..,41,,,,, - I...-.---11) s9 2\ D \ STATIC 11RE01 PSI ' � 'es .TmiNiiiiqiiRESIDUAL = 99 PSI gg l=-6 � L�LL / rel— 163 _ 2»DSP ci_ „4/ ilir- ftlimemiTiparmA lelAllow �,- FLOW 187 12 246.13'-8"PVC = \F EI / DIP IV S @ g STATIC 120 PSI 1 __. . Y 61.99' 8"PVC PITOT = 100 PSI . \ -------- I■ @1.699 J I iliac'NN 0) ______ , � FH 046 07. II \ �@ •73.96'-8"PVC � _5a.. ''''''. @13.68%o • m v v \*._,____. ' ,,,,1 ,,, 3 0- 1 ii, ---10w • I @6 4 2� @68 4. CS / SIC 9 lig '0' P S' o i i o \0.C)\? �.�x2% 0 BP\lc @ L 303 G� Z o o O V FH 060 �,"■ --`.11. ii 0,,,0 AFS Assurance Fire Systems FIRE SPRINKLER PRODUCT SUMITTALS FOR Red Sandstone Elementary School 551 N Frontage Road W Vail, CO 81621 r :303-798-4448 o :720-922-7698 10864 West Coco Place 40 :info@assurancefiresystems.com Littleton,CO 80127 :www.assurancefiresystems.com December 6, 2012 Sprinkler 89a C MIRAGE® QR EXTENDED NIKING TECHNICAL DATA COVERAGE LIGHT HAZARD ELO CONCEALED PENDENT SPRINKLER VK636(K11.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Mirage®Quick Response Extended CoverageLight Hazard ELO Concealed Pendent Sprinkler VK636 is a thermosensitive solder link spray sprinkler designed for installation on concealed pipe systems where the appearance of a smooth ceiling is desired.The 11.2K sprinkler meets Light Hazard density requirements at lower pressures than 5.6K or 8.0K sprinklers. The fusible operating element and special deflector characteristics meet the challenges of quick response extended coverage standards. The sprinkler is pre-assembled with a threaded adapter for installation with a low-profile cover assembly that provides up to '/z" (12.7 mm) of vertical adjust- ment.The two-piece design allows installation and testing of the sprinkler prior to installation of the cover plate.The"push-on","thread-off' design of the concealed cover plate assembly allows easy installation of the cover plate after the system has been tested and the ceiling finish has been applied.The cover assembly can For Light Hazard Occupancies Only be removed and reinstalled,allowing temporary removal of ceiling panels without taking the sprinkler system out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS cOus cULus Listed: CategoryVNIV Refer to the Approval C hart on page 89c and Design C riteria on page 89d for cULus Listing requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2010. Minimum Operating Pressure:7 psi (0.5 bar). Maximum Working Pressure:175 psi (12 bar).Factory tested hydrostatically to 500 psi (34.5 bar). Thread size: 3/4"(20 mm) NPT Nominal K-Factor: 11.2 U.S. (161.3 metric*) *Metric K-factor measurement is shown in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Patents Pending Material Standards: Sprinkler Body: Brass UNS-C 84400 Viking Technical Data may be found on Deflector: Brass UNS-C 23000 or Bronze UNS-C 51000 The Viking Corporation's Web site at Deflector Pins: Stainless Steel http://www.vikinggroupinc.com. Fusible Element Assembly:Nickel Alloy and Eutectic Solder The Web site may include a more recent Lever and Lever Bar:Stainless Steel Seat: Bronze UNS-C31400/UNS-C31600 edition of this Technical Data Page. Deflector Carrier: Brass UNS-C 84400 or QM Brass Screw:Brass UNS-C 36000 Belleville Spring Sealing Assembly:Nickel Alloy,coated on both sides with PTFE Tape CoverAdapter:C old Rolled Steel UNS-G10080, Finish: Clear C hromateover Zinc Plating Cover Assembly Materials: Cover:Brass UNS-C 26800 Base: Cold Rolled Steel UNS-G10060/G10080, Finish: Copper Flash Springs: Nickel Alloy Solder: Non-eutectic Ordering Information: (Also refer to the current Viking price list.) Viking Mirage®QR EC LH ELO C oncealed Pendent Sprinkler VK636 and Cover Plate Assembly must be ordered separately: Sprinkler: Base Part No. 16102A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix:165 °F (74°C)= C,205 °F (96°C)= E For example,sprinkler VK636 with a 165 °F (74 °C)temperature rating= 16102AC. Form No. F_121009 Replaces page 89a-e, dated August 12, 2011. (Revised Deflector and Deflector Carrier Materials) Sprinkler 89b December 6, 2012 ® MIRAGE® QR EXTENDED NIKING TECHNICAL DATA COVERAGE LIGHT HAZARD ELO CONCEALED PENDENT SPRINKLER VK636(K11.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Cover Plate Assembly: Base Part No. 15765 (3-5/16"diameter) Specify finish and temperature rating of the cover plate assembly by adding the appropriate suffixes for the finish and the cover temperature rating to the base part number: Finish Suffix: Polished Chrome= F,Painted White=M-/W, Painted Ivory= M-/I,Painted Black= M-/B Temperature Suffix: 135 °F (57°C)=A or 165 °F(74°C)=C For example,cover 15765 with a Polished Chromefinish and a 165 °F (74 °C)temperature rating= 15765FC. Available Finishes And Temperature Ratings: Refer to Table 1. Accessories: (Also refer to the"Sprinkler Accessories"section of the Viking data book.) Sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 15467W/B (available since 2009), or B. Head Cabinet Wrench Part No. 15466*** (available since 2009) C.Optional Concealed Cover Plate Installer Tool Part No. 14867 (available since 2007) **Requires a''IA"ratchet(not available from Viking).***Also optional for removal of the protective cap.Ideal for sprinkler cabinets. Sprinkler Cabinet: Part No. 01731A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions,when the temperature around the sprinkler approaches its operating temperature, the cover plate detaches. Continued heating of the exposed sprinkler causes the heat-sensitive fusible element assembly to disengage, releasing seat and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Model VK636 Sprinkler is available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGSAND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Temperature Rating of the Cover Plate Classification Temperature Rating' Ceiling Temperature2 Cover As d) Base Part No.3 135 °F (57°C) Ordinary 165 °F (74 °C) 100 °F (38 °C) 165 °F (74°C) 15765 Intermediate 205 °F (96 °C) 150 °F (65 °C) 165 °F (74°C) Cover Plate Finishes: Polished Chrome,Painted White, Painted Ivory, or Painted Black Footnotes 'The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading, sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Base part number is shown.For complete part number,refer to Viking's current price list schedule. December 6, 2012 Sprinkler 89c C MIRAGE® QR EXTENDED NIKING TECHNICAL DATA COVERAGE LIGHT HAZARD ELO CONCEALED PENDENT SPRINKLER VK636(K11.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com NPT Thread Size Nominal K-Factor Maximum Overall Length Sprinkler Base Water Working Pressure (Sprinkler Body) Part Number' Inches mm U.S. metric' Inches mm 16102A 3/4 20 11.2 161.3 175 psi(12 Bar) 2-7/16 61.8 ApprovaTChart Quick Response Extended Coverage Light Hazard ELO £paled Pendent Sprinkler VK636 611 Maximum SprinklerListings and Approvals' Minimum Water Supply Requirements4 Maximum Area Spacing Flow/Pressure Per Sprinkler (Refer also to Design Criteria on pg 89d.) (Length x Width) cULus5'6 FM NYC 16'x 16' (4.9 m x 4.9 m) 30 gpm @ 7.2 psi(113.6 L/min @.50 Bar) 256 ft?(23.8 m2) AW1,BX1 -- See Footnote7. 18'x 18' (5.5 m x 5.5 m) 33 gpm @ 8.7 psi(124.9 L/min @.60 Bar) 324 ft?(30.1 m2) AW1,BX1 -- See Footnote7. 20'x 20'(6.1 m x 6.1 m) 40 gpm @ 12.8 psi(151.4 L/min @.88 Bar) 400 ft?(37.2 m2) AW1,BX1 -- See Footnote7. Sprinkler Temperature Ratings Cover Assembly Temperature Ratings Cover Plate Finishes8 A-165 °F(74°C) W-135 °F(57°C)or 165 °F(74°C)cover 157651 1 - Polished Chrome, Painted White, Painted B-205°F(96°C) X-165 °F(74°C)cover 157651 Ivory,or Painted Black Footnotes 1 Part number shown is the base part number.For complete part number,refer to current Viking price list schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This chart shows the listings and approvals available at the time of printing.Other approvals may be in process.C heck with the manufacturer for any additional approvals. ^For areas of coverage smaller than shown,use the"Minimum Water Supply Requirement"for the next larger area listed. Flows and pressures listed are per sprinkler. 5 Listed by Underwriter's Laboratories, Inc.for use in the U.S.and Canada. 6cULus Listings are limited to Light Hazard occupancies with smooth,flat,horizontal ceilings only. 'Meets New York City requirements,effective July 1, 2008. 8 Painted finish consists of Polyester Baked Enamel. Other paint colors are available on request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer. Contact Viking for additional information. NOTE:C ustom colors are indicated on a label inside the cover assembly.Refer to Figure 1. \c0 C U S 0/7 9f y � o O v � VIKING Identification of Custom Paint Color: All custom color painted cover plates will have an identifying label affixed to the Inside of the cover that Indicates custom color and will have a representative sample (a paint dot) of the paint on the label Figure 1: Identification of Custom Paint Color for Concealed Covers Sprinkler 89d December 6, 2012 C MIRAGE® QR EXTENDED N1K1NGTECHNICAL DATA COVERAGE LIGHT HAZARD ELO CONCEALED PENDENT SPRINKLER VK636(K11.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer to the Approval Charton page 89c.) cULus Listing Requirements:Quick Response Extended C overageLight Hazard ELO Concealed Pendent Sprinkler VK636 is cULus Listed for instal- lation in accordance with the latest edition of NFPA 13 for extended coverage pendent spray sprinklers: • Limited to Light Hazard occupancies with smooth,flat,horizontal ceilings only. • Minimum spacing allowed is 8 ft.(2.4 m)unless baffles are installed in accordance with NFPA 13. • Minimum distance from walls is 4 in. (102 mm). • Maximum distance from walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured perpendicular to the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for extended coverage pendent spray sprinklers must be followed. NOTE:Concealed sprinklers must be installed in neutral or negative pressure plenums only. IMPORTANT: Always refer to Bulletin Form No. F_0 91699- Care and Handling of Sprinklers. Also refer to page EC1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Sprinkler Wrench Sprinkler �— �i — Flat 2-3/4" -to 2-7/8" I I Frame ,,,,19 � lI I (70 to 73 mm) I I Arms —`1 ' diameter opening ,I 1�I is required in I_i1 the ceiling Sprinkler and 1--------- ________ Adapter Assembly -- —/ _ �I■I< (Protective Cap Iii1 �,1�ii is removed for -_ '' , installation--use Wrench 15466**) NEVER install the sprinkler Sprinkler by applying the installation lin_,` , 41 Wrench wrench across the frame arms. (Part No, ^�^r, 15467W/Bw DO NOT overtighten. Use only the designated is shown) ��� sprinkler wrench, Viking Part **A 1/2" ratchet �_� Number 15467W/B or 15466. is required (not DO NOT apply more than available from Viking). 25 ft. lbs. of torquie. A leak =i tight seal should be achieved Step 2: Carefully press the by turning the sprinkler Step 1: Carefully slide the wrench upward and turn slightly clockwise 1 to 1-1/2 turns wrench sideways around to ensure engagement with the beyond finger tight. the deflector and pins, sprinkler wrench flats, Figure 2: Sprinkler Installation and Correct Use of Wrenches December 6, 2012 Sprinker 89e ® MIRAGE® QR EXTENDED NIKING TECHNICAL DATA COVERAGE LIGHT HAZARD ELO CONCEALED PENDENT SPRINKLER VK636(K11.2) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 3/4" � -- � (20 mm) NPT _ E---EI — I I 11 2-3/4" — -= (70 mm) 3" NM 2-1/2' (76 mm) (63,5 mm) - --_'- Maximum Minimum L"Ill3-5/16" (84,1 mm) Note Upon sprinkler activation, the deflector descends to approximately 1-1/16" (28 mm) below the sprinkler body. Figure 3: Sprinkler Dimensions and Cover Installation THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_121009 Replaces page 89a-e, dated August 12, 2011. (Revised Deflector and Deflector Carrier Materials) February 6, 2009 Sprinkler 54a MIRAGE° STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462AND HP SPRINKLER VK463(K5.6) The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1 . DESCRIPTION Viking Mirage®Standard and Quick Response Concealed Pendent SprinklerVK462 and HP Sprinkler VK463 are thermosensitive glass-bulbspray sprinklers designed for installa- tion on concealed pipe systems where the appearance of a smooth ceiling is desired. The sprinkler is pre-assembled with a threaded adapter for installationwith a low-profile cover assembly that provides up to 1/2" (12.7 mm) of vertical adjustment.The two-piece . design all owsinstallation and testing of the sprinkler prior to installation of the cover pl ate. The "push-on", "thread-off'design of the concealed cover plate assembly allowseasy installationof the cover pl ate after the system has been tested and the ceiling finish has been applied.The cover assembly can be removed and reinstalled,allowingtemporary removal of ceiling panels without taking the sprinkl ersystem out of service or removing the sprinkler. 2. LISTINGS AND APPROVALS cULus Listed:Category VNIV FM Approval:Class 2015 NYC Approved:MEA 89-92-E, Volume 32 VdS Approved:Certificate G4080021 LPC Approved: Ref.No. 096e/12 CE Certified:Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032 Refer to the Approval Chart on page 54c and Design Criteria on page 54d for cULus Listing requirements that must be fol l owed. 3. TECHNICAL DATA Specifications: Available since 2006. Minimum Operating Pressure:7 psi (0.5 bar)" Viking Technical Data may be found on Maximum Working Pressure: Sprinkler VK463 is rated for use with water working pressures ranging from the minimum 7 psi (0.5 bar)up to The Viking Corporation's Web site at 250 psi(17.2 bar)for high-pressure systems. High-pressure(HP) http://www.vikinggroupinc.com. sprinklers can be identified by locating"250"stamped on the deflec- The Web site may include a more recent tor.Sprinkler VK462 is rated to a maximum 175 psi(12 bar)wwp. edition of this Technical Data Page. Factory tested hydrostatical I y to 500 psi(34.5 bar) Testing: U.S.A. Patent No.4,831,870 Thread size: 1/2" (15 mm) NPT Nominal K-Factor: 5.6 U.S. (80.6 metrict) GI ass-bulb fluid temperature rated to-65 °F (-55°C) Patents Pending "cULus Listing, FM Approval,and NFPA 13 installs require a minimum of 7 psi (0.5 bar).The minimum operating pressure for LPCB and CE Approvals ONLY is 5 psi(0.35 bar). tMetric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Material Standards: Sprinkler Body: Brass UNS-C84400 Deflector:Copper UNS-C19500 for SprinklerVK462 Phosphor Bronze UNS-C51000 for Sprinkl erVK463 Deflector Pins: Stainless Steel Alloy Bulb:Glass, nominal 3 mm diameter Pip Cap and Insert Assembly:Copper UNS-C11000 and Stainless Steel UNS-S30400 Button: Brass UNS-C36000 Screws: 18-8 Stainless Steel Bel levil leSpring Sealing Assembly:Nickel Alloy,coated on both sides with TeflonTape Yoke: Phosphor Bronze UNS-C51000 Cover Adapter:Cold Rolled Steel UNS-G10080, Finish: Cl ear Chromate over Zinc Plating Form No. F_103005 Replaces page 54a-e, dated Sept. 12, 2008. (Added VdS Approval for Sprinkler 13503 with cover 13504). Sprinkler 54b February 6, 2009 MIRAGE° STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462AND HP SPRINKLER VK463(K5.6) The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Cover Assembly Materials: Cover:Copper UNS-C11000 Base: Brass UNS-C26000 or UNS-C26800 Springs:Nickel Alloy Solder: Eutectic Ordering Information:(Also refer to the currentViking price I ist) Viking Mirage®Standard and Quick Response Concealed Pendent Sprinklers and Cover Plate Assemblies must be ordered separately: Sprinkler: Base Part No. 13503A, 14697A, or HP Base Part No. 13667A Specify sprinkler temperature rating by adding the appropriate suffix for the temperature rating to the base part number: Temperature Suffix(°F/°C): 155°/68° = B, 175°/79° = D, 200°/93° = E For example,sprinkler VK463 with a 155 °F/68°C temperature rating= 13667AB. Cover Plate Assembly:Base Part No. 13504 (2-3/4"diameter), Base Part No. 13642 (3-5/16"diameter),or Base Part No. 15394 (square cover plate,3-5/16" diameter) Specify finish and temperature rating of the cover plate assembly by first adding the appropriate suffix for the finish and then the appropriate suffix for the cover temperature rating to the base part number: Finish Suffix:Polished Chrome= F,Painted White= M-/SW1004, Painted Ivory= M-/SW1634, Painted Black= M-/SW1007 Temperature Suffix(°F/°C): 135°/57° UL (139°/59°FM)=A, 165°/74° =C For example,cover 13504 with a Polished Chrome finish and a 165 °F/74°C temperature rating= 13504FC. Note:Square cover pl ate 15394 cULus Listing is for the 135 °F(57°C)temperature rated cover plateonly.Refer to the Approval Chart. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the"SprinklerAccessories"section of the Viking data book.) Sprinkler Wrenches**: A. Heavy Duty Wrench Part No. 14047W/B (available since 2006), or B. Head Cabinet Wrench Part No. 14031*** (available since 2006) C. Optional Concealed Cover Plate Instal I erTool Part No. 14412 for cover 13504, or Part No. 14867 for the I arge diameter cover (available since 2007) **Requires a 1/2"ratchet(not avail ablefrom Viking).***Optional for removal of the protective cap.Ideal for sprinkler cabinets. Sprinkler Cabinet:Part No. 01731A, Capacity:five(5)sprinklers(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions,when the temperature around the sprinkler approaches its operating temperature,the cover plate detaches. Continued heating of the exposed sprinklercauses the heat-sensitive I iquid in the gl ass bul b to expand and the bul b to shatter, rel easing the yoke, pip-cap and sealing spring assembly.Water fl owing through the sprinklerorifice strikes the sprinklerdeflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS,TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY Viking SprinklersVK462 and VK463 are available through a network of domestic and international distributors.See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current I ist price schedule or contact Viking directly. February 6, 2009 Sprinkler54c MIRAGE° STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462AND HP SPRINKLER VK463(K5.6) The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Approval ChartSprinkler Temperature Rating Cover Plate Temperature Rating Mirage°Concealed Pendent Sprinklers VK462 and VK463 AW1t Cover Plate Finish KEY NPT Overall Length Sprinkler Thread Nominal Maximum (Sprinkler Listings and Approvals4 Base SIN Size K-Factor Water Working Body) (Refer also to Design Criteria on page 54d.) Part No.' Inch mm U.S. metria Pressure Inches mm cULus' FM NYC' VdS LPCB C E ' Standard Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi(12 bar) 2-3/16" 56 -- AU1, BX1 -- AY1,CZ1 -- -- 14697A VK462 1/2" 15 5.6 80.6 175 psi(12 bar) 2-3/16" 56 -- -- -- -- AV2,BW2 AV2,BW2 Quick Response Applications 13503A VK462 1/2" 15 5.6 80.6 175 psi(12 bar) 2-3/16" 56 AV1, BX1 -- AV1, BW1 -- -- -- 14697A VK462 1/2" 15 5.6 80.6 175 psi(12 bar) 2-3/16" 56 AV1, BX1 -- AV1, BW1 -- -- -- 13667A VK463 1/2" 15 5.6 80.6 250 psi(17.2 bar)3 2-3/16" 56 AV1, BX1 -- AV1, BW1 -- -- -- Cover Plate Assembly Temperature Ratings° U-135 °F(57°C)cULus Listed cover 135041, 136421 (I arge diameter), or 153941 (square cover pl ate) Sprinkler Temperature Ratings FM Approved as 139°F(59°C) V - 135 °F (57 °C) cULus Listed cover 135041 or Finishes of the Cover Plate Assembly' A- 155 °F(68°C) 13642' (I arge diameter) 1 -Polished Chrome, Painted White, Painted Ivory,or B - 175 °F (79°C) and 200 °F W - 165 °F (74 °C) cover 135041 or 136421 (large Painted Black (93°C) diameter) 2-Polished Chrome,Painted White C-200 °F(93°C) X- 165 °F (74 °C)cover 135041, 136421 (large diam- eter),or 153941(square cover plate) Y- 135 °F(57°C)cover 135041 Z- 165 °F(74°C)cover 135041 Footnotes 1 Part number shown is the base part number.For complete part number,refer to current Viking price I ist schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3The Water Working Pressure rating is stamped on the deflector. This chart shows the listings and approval savail abl eat the time of printing.Other approval smay be in process.Check with the manufacturer for any additional approvals. 5 Listed by Underwriter's Laboratories for use in the U.S.and Canada. 6 Accepted for use,City of New York Department of Buildings,MEA Number 89-92-E,Vol.32. 7(E Certified,Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2032. 8 The 135/139 °F cover has an orange I abel.The 165 °F cover has a white I abel. ' Painted finish consists of Polyester Baked Enamel.Other paint colors are availableon request with the same listings as the standard paint colors. Listings and approvals apply for any paint manufacturer.Contact Viking for additional information. NOTE:Custom colorsare indicated on a label inside the cover assembly.Refer to Figure 1. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Temperature Rating of Cover Bulb Color Classification _ Temperature Rating' Ceiling Temperature2 Assembly(Required) Ordinary 155 °F (68 °C) 100 °F (38 °C) 135 °F (57°C)cULus Red 139 °F (59°C) FM Intermediate 175 °F (79 °C) 150 °F (65°C) 165 °F (74 °C) Yellow Intermediate 200 °F (93°C) 150 °F (65°C) 165 °F (74 °C) Green Cover Plate Finishes: Polished Chrome, Painted White, Painted Ivory,or Painted Black Footnotes 1 The sprinklertemperature rating is stamped on the sprinkler deflector. 2 Based on NFPA-13. Other limits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. Sprinkler54d February 6, 2009 MIRAGE° STANDARD AND TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462 AND HP SPRINKLER VK463(K5.6) The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Al so refer to the Approval Chart on page 54c.) cULus Listing Requirements: Mirage®Standard and Quick Response Concealed Pendent Sprinklers VK462 and VK463 are cULus Listed for instal I ationin accordance with the I atest edition of NFPA 13 for standard coverage pendent spray sprinklers as indicated below. • For hazard occupancies up to and including Ordinary Hazard,Group II. • Protection areas and maximum spacing shal I be in accordance with the tables provided in NFPA 13. Maximum spacing al I owed is 15 ft.(4.6 m). • Minimum spacing allowed is 6 ft.(1.8 m)unless bafflesare installed in accordance with NFPA 13. • Minimum distance from wal is is 4 in.(102 mm). • Maximum distance from wallsshalI be no more than one-half of the allowabledistance between sprinkl ers.The distance shall be measured perpendicul ar to the wal I. • The sprinklerobstruction rules contained in NFPA 13 for standard coverage pendent spray sprinklersmust be fol I owed. NOTE:Concealed sprinklers must be installed in neutral or negative pressure plenums only. FM Approval Reauirements: Mirage®Concealed Pendent SprinklerVK462 is FM Approved as a standard response standard spray sprinkl eras indicated in the Approval Chart for hazard occupancies up to and including Ordinary Hazard, Group II. For installation in accordance with the latest applicable FM Leas Prevention Data Sheets(incl uding 2-8N)and Technical AdvisoryBul I etins.FM Global Loss Prevention Data Sheets and Technical Advisory BulI etinscontain guidelines rel atingto,but not I imitedto:minimum water supply requirements,hydraul icdesign,ceiling sl opeand obstructions, minimum and maximum allowable spacing,and deflector distance bel ow the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page SR1-3 or QR1-3 for general care,installation,and maintenance information. Viking sprinklers are to be installed in accordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB,APSAD,VdS or other similar organizations,and also with the provisions of governmental codes, ordi- nances, and standards,whenever applicable. \o U S D❑ NOT PAINT 9f, y � o r— O v V2C- NIKING Identification of Custom Paint Color: All custom color painted cover plates will have an identifying label affixed to the Inside of the cover that indicates custom 3-5/16" (84,1 mm) color and will have a representative sample (a paint dot) of the paint on the label Figure 1: Identification of Custom Paint Color for Concealed Covers Figure 2: Square Cover Assembly 15 394 February 6, 2009 Sprinkler54e MIRAGE° STANDARD AND NII(ING TECHNICAL DATA QR CONCEALED PENDENT SPRINKLER VK462AND HP SPRINKLER VK463(K5.6) The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Sprinkler r_ —, Wrench i�° Flat Sprinkler , ILII.lir. „I1� " 2-1/4" (57.2 mm) Frame \ diameter opening Arms bilF� L is required in =�\ `I��I the ceiling. :- �J Sprinkler and — -�!o 1—� Adapter Assembly LI! .. ........ MI (Protective Cap is removed for ommmmm i --use 1���m�II� _- - nstallation THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_103005 Replaces page 54a-e, dated Sept. 12, 2008. (Added VdS Approval for Sprinkler 13503 with cover 13504). April 25, 2008 Sprinkler 51a MICROFAST°AND TECHNICAL DATA MicrofastHP° QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Teleph one: 269-945-9501 Tech nicalServices 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast° and MicrofastHP° Quick Response Upright and Conventional (Old Style) Sprinklers are small, thermosensitive, glass-bulb spray sprinklers -� +rrr- available in several different finishes, temperature ratings, and K-Factors to „Y meet design requirements. The special Polyester and Teflon° coatings y ' " can be used in decorative applications where colors are desired. In addi- tion, these coatings have been investigated for installation in corrosive atmos- pheres and are cU Lus listed as corrosion resistant as indicated in the Approval Chart.(Note:FM Global has no approval classification for Teflon°and Polyester coat- °I/1 % a ings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved:Class 2020 NYC Approved:Calendar Number 219-76-SA and MEA 89-92-E,Volume 16 ABS Certified:Certificate 04-HS407984B-PDA VdS Approved:Certificate G4060054, G4060056, G4880046, G4930039, and G4980020 LPC Approved:Ref.No. 096e/03,TE30401, and TE30872 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40131, and 0786-CPD-40171 MED Certified:Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 51d and Design Criteria on page 51e for cU Lus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1987. Minimum Operating Pressure:7 psi (0.5 bar) Maximum Working Pressure:Sprinklers VK315 and VK340 are rated for Viking Tech nical Data may be found on use with water working pressures ranging from the minimum 7 psi The Viking Corporation's Web site at (0.5 bar)up to 250 psi (17 bar)for high-pressuresystems. High-pres- http://www.vikinggroupinc.com. sure(HP)sprinklers can be identified by locating"250" stamped on The Web site may include a more recent the deflector.All other Part Nos. not mentioned above are rated to a edition of this Tech nical Data Page. maximum 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing:U.S.A.Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to-65 °F (-55°C) Overall Length: Refer to the Approval Chart Material Standards: Frame Casting: Brass U NS-C84400 Deflector: Brass U NS-C23000 or Copper U NS-C19500 for Sprinklers 06661B and 12281. Copper U NS-C19500 for Sprinklers 06665B, 06764B, and 07060. Brass U NS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06719B, 06717B, and 12286): Brass U NS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly:Nickel Alloy,coated on both sides with Teflon Tape Screw:Brass U NS-C36000 Pip Cap and Insert Assembly:Copper U NS-C11000 and Stainless Steel U NS-S30400 For Teflon°Coated Sprinklers: Belleville Spring-Exposed,Screw-Nickel Plated, Pip Cap-Teflon®Coated Form No. F_080488 Replaces page 51a-e, dated March 7, 2008. (U pdated LPCB Approval on Sprinkler 14817.) Sprinkler 51b April 25, 2008 MICROFAST°AND VIKING TECHNICAL DATA MicrofastHP° QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Tech nical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information:(Also refer to the current Viking price list.) Order Microfast°and MicrofastHP°Quick Response Upright and Conventional Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass=A, Chrome-Enloy'= F,White Polyester= M-/W,Black Polyester= M-/B,and Black Teflon°= N Temperature Suffix (°F/°C): 135°/68° =A, 155°/68° = B, 175°/79° = D, 200°/93° = E, and 286°/141° = G For example,sprinkler VK300 with a 1/2" thread, Brass finish and a 155 °F/68°C temperature rating= Part No. 06661BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: Standard Wrench:Part No. 10896W/B (available since 2000) Sprinkler Cabinets: A. Six-head capacity:Part No. 01724A (available since 1971) B.Twelve-head capacity:Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions,the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS,TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast° and MicrofastHP° Quick Response Upright and Conventional Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. April 25, 2008 Sprinkler 51c MICROFASP AND NIKING TECHNICAL DATA MicrofastHP° QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Teleph one: 269-945-9501 Tech nical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGSAND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 135 °F (57 °C) 100 °F (38 °C) Orange Ordinary 155 °F (68°C) 100 °F (38 °C) Red Intermediate 175 °F (79°C) 150 °F (65 °C) Yellow Intermediate 200 °F (93°C) 150 °F (65 °C) Green High 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass,Chrome-Enlo/®, White Polyester, Black Polyester, and Black Teflon° Corrosion-Resistant Coatings': White Polyester, Black Polyester, and Black Teflon° Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading, sprinkler location,and other requirements of the Authority Having Jurisdiction.Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 51d. These tests cannot and do not represent all possible corrosive environments.Prior to installation, verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon° coatings. Protective Wrench SprinkWr Plat Ca �� 0 p 0896 /. Figure 1: Standard Sprinkler Wrench 10896W/B Sprinkler 51d April 25, 2008 MICROFASP AND VIKING TECHNICAL DATA MicrofastHP® QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Tech nicalServices 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Approval Chart Temperature KEY Microfast®and MicrofastHP®Quick Response l+-Finish Upright and Conventional Sprinklers A1X F Escutcheon(if applicable) Maximum 175 PSI 12 bar)WWP Base Part Th read Size Nominal Overall Length Listings and Approvals3 Number' SIN K-Factor (Refer also to Design Criteria on page 51e.) NPT BSP U.S. metric2 Inches mm cULus4 FM' NYC9 VdS LPCB CE Upright-Standard Orifice 06661B VK300 1/2" 15 mm 5.6 80.6 2-3/16 56 A2 A3 A2 -- -- -- -- 07060 VK345 -- 15 mm 5.6 80.6 2-3/16 56 -- A3 -- A3 A3 B312 B314 Conventional-Standard Orifice 06766B VK310 I 1/2" 115 mm I 5.6 I 80.6 I 2-3/16 I 56 I A3 -- A3 -- A3 I 8312 I B314 Upright-Large Orifice 06665B VK350 3/4" -- 8.0 115.2 2-5/16 59 A2 A3 A2 A3 A3 B312 -- 14817 VK350 -- 20 mm 8.0 115.2 2-5/16 59 A2 A3 A2 A3 A3 B312 -- 06764B VK350 1/2" 15 mm 8.0 115.2 2-5/16 59 A2 -- A2 A3 -- -- -- Conventional-Large Orifice 06768B VK354 I 3/4" 120 mm I 8.0 I 115.2 I 2-5/16 I 59 I A2 -- A3 -- A3 I 8312 I -- Uprigh t-Small Orifice10 06717B11 VK325 1/2" 15 mm 2.8 40.3 2-3/16 56 A2 Al A2 -- -- -- -- 067196" VK327 1/2" 15 mm 4.2 60.5 2-3/16 56 A2 -- A2 -- -- -- -- 069316" VK327 -- 10 mm 4.2 60.5 2-3/16 56 -- -- -- A3 -- E113 -- Maximum 250 PSI(17 bar)WWP Upright-Standard Orifice Base Part Th read Size Nominal Overall Length Listings and Approvals3 SINK-Factor (Refer also to Design Criteria on pa a 51e. Number NPT BSP U.S. metric2 Inches mm cULus4 FM NYC9 VdS LPCB (E 0 12281 VK315 1/2" 15 mm 5.6 80.6 2-3/16 56 A2 -- A2 -- -- - _ Upright-SmallOrifice10 1228611 I VK340 I 1/2" 115 mm I 2.8 I 40.3 I 2-3/16 56 I A2 I -- A2 -- -- -- I -- Approved Temperature Ratings A- 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), Approved Finish es and 286 °F (141°C) 1 - Brass and Chrome-Enloyf' B- 155 °F (68 °C), 175 °F (79°C),200 °F (93°C), and 286 °F (141°C) 2 - Brass, Chrome-Enloy', White Polyester5'6, Black Polyester5,6 C- 135 °F (57°C), 155 °F (68°C), 175 °F (79°C), and 286 °F (141°C) and Black Teflon®5 D- 135 °F (57°C), 155 °F (68°C),and 175 °F (79°C) 3- Brass,Chrome-Enloy®, White Polyester6•6, and Black Polyester5.6 E-155 °F (68°C) Footnotes 'Base part number is shown.For complete part number,refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. 5 cU Lus Listed as corrosion resistant. 6 Other colors are available on request with the same Listings and Approvals as the standard colors. For installation in accordance with the latest applicable FM Loss Prevention Data Sheets and Technical Advisory Bulletins. 'Accepted for use, City of New York Board of Standards and Appeals,Calendar Number 219-76-SA. 'Accepted for use, City of New York Department of Buildings, MEA 89-92-E,Vol.16. 10 Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet systems only. Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 11The sprinkler orifice is bushed. 12(E Certified,Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 13 CE Certified,Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40131. 14 2 MED Certified,Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. April 25, 2008 Sprinkler 51e MICROFAST°AND TECHNICAL DATA MicrofastHP° QUICK RESPONSE UPRIGHT AND CONVENTIONAL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Tech nicalServices 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com (Also refer to the ApprovalDESIGN Chart onCRITERIA page 51d) cULus Listing Requirements: Microfast®and MicrofastHP®Quick Response U pright and Conventional Sprinklers are cU Lus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers,or old style(conventional)sprinklers. • Designed for use in Light and Ordinary Hazard occupancies(exception:small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). • The sprinkler installation rules contained in NFPA 13 for standard spray upright sprinklers must be followed.For conventional sprinklers, refer to the installation guidelines for old style(conventional)sprinklers. FM Approval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data Sheets(including 2-8N)and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers.Also refer to page QR1-3 for general care, installation, and maintenance information.Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking tech nical data, the appropriate standards of NFPA,FM Global, LPCB, APSAD,VdS or oth ersimilar organizations,and also with the provisions of governmental codes, ordinances,and standards,whenever applicable. THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_080488 Replaces page 51a-e, dated March 7, 2008. (U pdated LPCB Approval on Sprinkler 14817.) March 14, 2008 Sprinkler 41a MI R•FA T°AND MicrofastHP® QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLERS The V ikingCorporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast® and MicrofastHP® Quick Response Pendent Sprinklers are small, thermosensitive,glass-bulb spray sprinklers available in several different finishes and10- temperature ratings and K-Factors to meet design requirements.The special Polyester and Teflon®coatings can be used in decorative applications where colors are desired. In addition, these coatings have been investigated for installation in corrosive at- _ mospheres and are cULus listed as corrosion resistant as indicated in the Approval Chart.(Note:FM Global has no approval classification for Teflon®and Polyester coat- \41 11- ings as corrosion resistant.) 2. LISTINGS AND APPROVALS — _— cULus Listed: Category VNIV FM Approved:Class 2020 NYC Approved:Calendar Number 219-76-SA and MEA 89-92-E,Volume 16 ABS Certified:Certificate 04-HS407984C-PDA V dS Approved:Certificate G4040095, G4040097, G4060056, G4060057, G4880045, G4930038, and G4980021 LPC Approved:Ref.No. 096e/03 and 096e/04 CE Certified: Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001, 0832-CPD-2003, 0786-CPD-40130, and 0786-CP D-40170 MED Certified:Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008 NOTE: Other International approval certificates are available upon request. Refer to the Approval Chart on page 41d and Design Criteria on page 41e for cULus and FM approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1987. Viking Technical Data may be found on Minimum Operating Pressure:7 psi (0.5 bar) The Viking Corporation's Web site at Maximum Working Pressure:Sprinklers 12282 and 12290 are rated for http://www.vikinggroupinc.com. use with water working pressures ranging from the minimum 7 psi The Web site may include a more recent (0.5 bar)up to 250 psi (17 bar)for high-pressure systems. High-pres- edition of this Technical Data Page. sure(HP)sprinklers can be identified by locating"250" stamped on the deflector.All other Part Nos. not mentioned above are rated to a maximum 175 psi (12 bar)wwp. Factory tested hydrostatically to 500 psi (34.5 bar) Testing:U.S.A.Patent No. 4,831,870 Thread size: Refer to the Approval Chart Nominal K-Factor: Refer to the Approval Chart Glass-bulb fluid temperature rated to-65 °F (-55°C) Overall Length: Refer to the Approval Chart Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Phosphor Bronze UNS-C51000 or Copper UNS-C19500 for Sprinklers 06662B, 06666B, 06765B, and 12104. Copper UNS-C19500 for Sprinkler 12282. Brass UNS-C26000 for all other Sprinklers. Bushing (for Sprinklers 06718B, 06720B, and 12290): Brass UNS-C36000 Bulb: Glass, nominal 3 mm diameter Belleville SpringSealingAssembly:Nickel Alloy,coated on both sides with Teflon Tape Screw:Brass UNS-C36000 Pip Cap and Insert Assembly:Copper UNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment:Brass UNS-C36000 Ejector Spring(for Sprinkler 12104): Stainless Steel Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 06666B,Added Dry System note in approval chart for S mall Orifice.) Sprinkler 41b March 14, 2008 MI R•FA T®AND KI TECHNICAL DATA MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings Ml 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com For Teflon°Coated Sprinklers: Belleville Spring-Exposed,Screw-Nickel Plated, Pip Cap-Teflon®Coated For Polyester Coated Sprinklers: Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking price list.) Order Microfast°and MicrofastHP°Quick Response Pendent Sprinklers by first adding the appropriate suffix for the sprinkler fin- ish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix:Brass=A, Chrome-Enlo/®= F,White Polyester= M-/W,Black Polyester= M-/B,and Black Teflon°= N Temperature Suffix(°F/°C): 135°/68° =A, 155°/68° = B, 175°/79° = D, 200°/93°= E, and 286°/141° = G For example,sprinkler VK302 with a 1/2" thread, Brass finish and a 155 °F/68°C temperature rating= Part No. 06662BAB Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the"Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench:Part No. 10896W/B (available since 2000). B.Wrench for coated and/or recessed sprinklers: Part No. 12144W/B**(available since 2003) NOTE: RECESSED PENDENT SPRINKLERS WITH PROTECTIV ECAPS MUST USE WRENCH 12144W/B. "A 1/2"ratchet is required(not available from Viking). Sprinkler Cabinets: A. Six-head capacity:Part No. 01724A (available since 1971) B.Twelve-head capacity:Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter,releasing the pip cap and sealing spring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Microfast®and MicrofastHP°Quick Response Pendent Wrench Sprinklers are available through a network of domestic and Slats international distributors. See The Viking Corporation web site for P r o t e c t i v e the closest distributor or contact The Viking Corporation. /�ogaeaki1 S p r i n k l e r Cap 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. O:96 ED) Figure 1: Standard Sprinkler Wrench 10896W/B March 14, 2008 Sprinkler 41c MICROFASP AND VIKING TECHNICAL DATA MicrofastHP° QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nomina Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 135 °F (57°C) 100 °F (38 °C) Orange Ordinary 155 °F (68°C) 100 °F (38°C) Red Intermediate 175 °F (79°C) 150 °F (65°C) Yellow Intermediate 200 °F (93°C) 150 °F (65°C) Green High 286°F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy/, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings4: White Polyester, Black Polyester, and Black Teflon® Footnotes ' The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may apply,depending on fire loading, sprinkler location,and other requirements of the Authority Having Jurisdiction.Refer to specific installation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the approving agencies indicated on pages 41d. These tests cannot and do not represent all possible corrosive environments.Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment. For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon°coatings. 1�,,-/Il �n%�in II — ,�I y � — Sprinkler Wrench 12144W/B®x for installing coated \vim 1111 and/or recessed pendent sprinklers H Carefully slide the f with protective caps wrench sideways r 1 around the protective cap, ensuring engage- = ` ment with the sprinkler =; )KXA 1/2" ratchet is required wrench flats, (not available from Viking). Figure 2: Wrench 12144W/B for Coated and/or Recessed Pendent Sprinklers Sprinkler 41d March 14, 2008 MICROFASP AND VIKING IIMicrofastHP® QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLERS The V iking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com Approval Chart Temperature KEY Microfast®and MicrofastHP®Quick Response Pendent S rinklers Finish p p A1X�Escutcheon(if applicable) Maximum 175 P12 bar)WWP ill Sprinkler Thread Size Nominal Overall Listings and Approvals3 Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No.1 NPT BSP U.S. metric2 Inches mm cULus4 FMS NYCE V dS LPCB (E 00 Standard Orifice 06662B VK302 1/2" 15 mm 5.6 80.6 2-1/4" 58 AIX,BIY A3X,B3Y A1X, B1Y A3 A3X,B3Y C3X, E3Y13 C3X,E3Y15 Large Orifice 06666B VK352 3/4" 20 mm 8.0 115.2 2-3/8" 60 AIX,B1Y A2X, B2Y A1X, B1Y -- A3X C313 -- 12104 VK352 3/4" 20 mm 8.0 115.2 2-1/4" 58 -- -- -- G3 -- -- -- 06765B VK352 1/2" 15 mm 8.0 115.2 2-3/8" 60 A1X,B1Y -- A1X,B1Y A3 -- -- -- Small Orifice" 06718B10 VK329 1/2" 15 mm 2.8 40.3 2-3/16" 56 A1X,B1Y A2X A1X,BIY -- -- -- -- 0672061° VK331 1/2" 15 mm 4.2 60.5 2-1/4" 58 AIX,BIY -- AIX,BIY -- -- -- -- 06932B VK331 -- 10 mm 4.2 60.5 2-3/8" 60 -- -- -- A3 -- G214 -- Maximum 250 PSI (17 bar)WWP Standard Orifice Sprinkler Thread Size Nominal Overall Listings and Approvals' Base SIN K-Factor Length (Refer also to Design Criteria on page 41e.) Part No' NPT BSP U.S. metric2 Inches mm 1 cULus4 FM NYC11 VdS LPCB (E 0 12282 VK317 1/2" 15 mm 5.6 80.6 2-1/4" 58 A1X,B1Y -- A1X -- -- -- -- Maximum 250 PSI (17 bar)WWP Small Orifice' 1229010 VK342 1/2" 15 mm 2.8 40.31 2-3/16" 56 A1X,B1Y -- AIX -- -- -- -- Approved Temperature Ratings Approved Escutcheons A-135°F(57°C), 155°F(68°C), 175°F(79°C),200°F(93°C), Approved Finishes X - Standard surface-mounted escutcheon or and 286°F(141 °C) 1 - Brass, Chrome-Enloyu, White Poly- the Viking Microfast® Model F-1 Adjustable B-135°F(57°C),155°F(68°C),175°F(79°C),and 200°F(93°C) ester78, Black Pol ester78, and Black Escutcheon" - 155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), and 286 °F y (141 °C) Teflon®7 Y - Standard surface-mounted escutcheon or D - 135 °F (57 °C), 155 °F (68 °C), 175 °F (79 °C), and 286 °F 2-Brass and Chrome-Enloe'' the Viking Microfast Model F-1 Adjustable (141 °C) 3-Brass,Chrome-Enloy®,White Polyester', Escutcheon12 or recessed with the Viking E-155 °F(68°C), 175 °F(79°C),and 200°F(93°C) and Black Polyester' Micromatid® Model E-1 or E-2 Recessed F- 155 °F(68°C), 175 °F(79°C),and 286°F(141 °C) Escutcheon G-155°F(68°C) Footnotes 1 Base part number is shown.For complete part number,refer to Viking's current price schedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and approvals available at the time of printing.Check with the manufacturer for any additional approvals. 4 Listed by Underwriters Laboratories Inc.for use in the U.S.and Canada. 5 FM Approved for use only in wet-pipe sprinkler systems(or preaction systems qualifying as wet systems)for protection of occupancies described in the Factory Mutual Engineering and Research Loss Prevention Data Sheets and TechnicalAdvisory Bulletins. 'Accepted for use,City of New York Board of Standards and Appeals,Calendar Number 219-76-SA. 'cULus Listed as corrosion resistant. 8 Other colors are available on request with the same Listings and Approvals as the standard colors. 'Listings and Approvals limited to Light Hazard Occupancies where allowed by the installation standards being applied,with hydraulically calculated wet systems only.Exception:4.2K sprinklers may be installed on hydraulically calculated dry pipe systems where piping is corrosion resistant or internally galvanized. 10The sprinkler orifice is bushed. "Accepted for use,City of New York Department of Buildings, MEA Number 89-92-E,Vol.16. 12The Viking Microfast® Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. 13 LE Certified,Standard EN 12259-1, EC-certificate of conformity 0832-CPD-2001 and 0832-CPD-2003. 14 CE Certified,Standard EN 12259-1, EC-certificate of conformity 0786-CPD-40130 and 0786-CPD-40170. 15 -MED Certified,Standard EN 12259-1, EC-certificate of conformity 0832-MED-1003 and 0832-MED-1008. March 14, 2008 Sprinkler 41e MICROFASP AND VIKING TECHNICAL DATA MicrofastHP® QUICK RESPONSE PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com DESIGN CRITERIA Malb (Also refer to the Approval Chart on page 41d) cULus Listing Requirements: Microfast®and MicrofastHP®Quick Response Pendent Sprinklers are cULus Listed as indicated in the Approval Chart for installation in accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies(exception:small orifice sprinklers are limited to Light Hazard where allowed by the installation standards being applied, with hydraulically calculated wet systems only). • The sprinkler installation rules contained in NFPA 13 for standard spray pendent sprinklers must be followed. FM Approval Requirements: For installation in accordance with the latest applicable FM Loss Prevention Data S heets(including 2-8N)and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and Technical Advisory Bulletins contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,V dS or other similar organizations,and also with the provisions of governmental codes, ordinances,and standards,whenever applicable. Ceiling Opening Size: 2-5/16" (58.7 mm) minimum 2-1/8" ms 2-1/2" (63.5 mm) maximum (54 mm) 1/2' - (15 mm) NPT aiNI £ i �C�➢91a01o0� 1-3/4" f � 2-1/4" (44.5 mm) 2" (50,8 mm) 1-1/2" (38,1 mm) (58 mm) -' (41 rim) Minimum= Maximum Installed with a Pendent Sprinkler standard 1/8" surface- 06662B (VK302) mounted escutcheon. Installed with a Microfast Model F-1 Adjustable Escutcheon Figure 3: Sprinkler V K302 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Sprinkler 41f March 14, 2008 MICROFASP AND NIII<ING I(IMicrofastHP® QUICK TECHNICAL DATA RESPONSE PENDENT SPRINKLERS The V iking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-945-4495 Email: techsvcs@vikingcorp.com 2-1/8" Ceiling Opening Size: 2-1/8" _ (54 mm) 2-5/16" (58,7 mm) minimum (54 mm) 2-1/2" (63,5 mm) maximum Ir 'MI NM 1-1/8" (28,6 mm) 1-3/4" = Minimum 2" lly 1-1/8" (28,6 mm) (44.5 mm) A Minimum Maximum - (50.8 mm) t \ iMaximum _.. Installed with a Micromatic Model E-1 Recessed Escutcheon Installed with a thread on Model E-2 Recessed Escutcheon Figure 4: Sprinkler V K302 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_081296 Replaces page 41a-f, dated October 12, 2007. (Added LPCB Approval and updated CE Approval for Sprinkler 06666B, Added Dry System note in approval chart for Small Orifice.) February 13, 2009 Sprinkler43a MI R•FA AND MI R'- NII<ING TECHNICAL DATA FASTHR) QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLERS (VK305&VK319) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1. DESCRIPTION Viking Microfast° and MicrofastHP°Quick Resp onse Horizontal Sidewall Sprinklers are small thermosensitive glass bulb spray sprinklers available with various finishes and temperature ratings to meet design requirements. The special Polyester and Teflon° coatings can be used in decorative app licationswhere colors are desired. - In addition, these coatings have been investigated for installation in corrosive at mosp heres and are cULus listed as corrosion resistant as indicated in the Approval Chart.(Note:FM Global has no approvablassificationforTeflon®and Polyester coat- ings as corrosion resistant.) 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2020 NYC Approved: MEA 89-92-E,Volume 16 Refer to the App rovaChart on p age 43d and Design Criteria on p age 43e for cULus and FM app rovalrequirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 2003. Minimum Operating Pressure:7 psi(0.5 bar) Maximum Working Pressure: Sprinkler VK319 is rated for use with water Viking Technical Data may be found on working pressures ranging from the minimum 7 psi (0.5 bar) up to The Viking Corporation's Web site at 250 psi (17 bar)for high-pressure systems. High-pressure (HP)sprin- http://www.vikinggroupinc.com. klers can be identified by locating "250"stamped on the deflector. The Web site may include a more recent Sprinkler VK305 is rated to a maximum 175 psi (12 bar)wwp. edition of this Technical Data Page. Factory tested hydrostatically to 500 psi(34.5 bar) Testing:U.S.A. Patent No. 4,831,870 Nominal K-Factor: 5.6 U.S. (80.6 metric*) *Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. Glass-bulb fluid temperature rated to-65 °F (-55°C) Overall Length:2-11/16" (68 mm) Material Standards: Frame Casting: Brass UNS-C84400 Deflector: Cop p erU NS-C 19500 Bulb: Glass, nominal 3 mm diameter Belleville Sp ring Sealing Assembly:Nickel Alloy,coated on both sides with Teflon Tap e Screw:Brass UNS-C36000 Pip Cap:CopperUNS-C11000 and Stainless Steel UNS-S30400 Pip Cap Attachment:Brass UNS-C36000 For Teflon°Coated Sp rinklers:Belleville Sp ring-Exposed,Screw-Nickel Plated, Pip Cap-Teflon®Coated For Polyester Coated Sprinklers:Belleville Spring-Exposed Ordering Information: (Also refer to the current Viking p rice list.) Order Quick Resp onse Horizontal Sidewall Sprinklers by first adding the appropriate suffix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix:Brass=A, Chrome-Enloy°= F,White Polyester= M-/W,Black Polyester= M-/B,and Black Teflon°= N Temperature Suffix(°F/°C):135°/68°=A, 155°/68°= B, 175°/79°= D,200°/93°= E, and 286°/141° = G For example,sprinkler VK305 with a Brass finish and a 155 °F/68°C temperature rating= Part No. 12121AB Form No. F_030103 Rep lacesp age43a-f,dated March2,2007.(RevisedFM Design Criteria.Added the Model G-1 Escutcheon.) Sprinkler43b February 13, 2009 MI R•FA PAND MI VR'- FASTHP� QUICK RESPONSE 11UNGTECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLERS (VK305&VK319) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the"Sp rinklerAccessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench:Part No. 10896W/B (available since 2000). B.Wrench for recessed sprinklers with protective shields: Part No. 13655W/B**(available since 2003) "A1/2"ratchet is required(not available from Viking). Sprinkler Cabinets: A. Six-head capacity:Part No. 01724A (available since 1971) B.Twelve-head capacity:Part No. 01725A(available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions,the heat-sensitive liquid in the glass bulb expands,causing the glass to shatter,releasing the pip cap and sealing sp ring assembly.Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform sp ray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY Viking Quick Response Horizontal Sidewall Sprinklers are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Wrench SprinkLer ShleLd © LTE Plat /11i,fir-allliilliiiihill ,...., 1 110896 ED Figure 1: Standard Sprinkler Wrench 10896WB February 13, 2009 Sprinkler43c MI R•FA T®AND MICRO- NI IKING TECHNICAL DATA 1(1FASTHP® QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLERS (VK305&VK319) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-950WTechnical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 — Ordinary 135 °F (57°C) 100 °F (38 °C) Orange Ordinary 155 °F (68°C) 100 °F (38 °C) Red Intermediate 175 °F (79°C) 150 °F (65°C) Yellow Intermediate 200 °F (93°C) 150 °F (65°C) Green High 286°F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass,Chrome-Enloy°, White Polyester, Black Polyester, and Black Teflon® Corrosion-Resistant Coatings3: White Polyester, Black Polyester, and Black Teflon® Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other limits may app ly,dep ending on fire loading, sprinkler location,and other requirements of the Authority Having Jurisdiction.Refer to specificinstallation standards. 3 The corrosion-resistant coatings have passed the standard corrosion test required by the app rovingagencies indicated in the App rovaChart.These tests cannot and do not represent all possible corrosive environments.Prior to installation, verify through the end-user that the coatings are comp atiblewith or suitable for the prop osedenvironment.For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the sp ring is exposed on sprinklers with Polyester and Teflon®coatings. Sprinkler Wrench Part No. 13655W/B* for Recessed Horizontal Sidewall Sprinklers Protective Fit the wrench over the sprinkler Sprinkler and protective shield as shown. Shield 11 ll V,--- El 11 \ i i I *Note: A 1/2" ratchet is required (not available from Viking). Figure 2: Wrench 13655W/B for Recessed Horizontal Sidewall Sprinklers Sp rinkler43d February 13, 2009 MI R•FA T''AND MI R.- FASTHP� QUICK RESPONSE TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLERS (VK305&VK319) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart "Fnsherature KEY Microfast®and MicrofastHP®Quick Response A1X41-Escutcheon(if applicable) Horizonliailiallarinklers Nominal Listings and Approvals' Base Part SIN Maximum Thread Size K-Factor Overall Length (Refer also to Design Criteria on pg 43e.) Number' Pressure C c NPT BSP U.S. metric2 Inches mm cULus4 FM NYC5 LPCB Maximum 175 PSI(12 Bar)WWP For Light or Ordinary Hazard Occupancies. Deflectors must be located 4"to 12" (102 mm to 305 mm)below the ceiling. 12121 VK305 175 psi 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y,B1X -- A1Y -- -- -- Maximum 175 PSI WWP For Light Hazard Occupancies Only. Deflectors must be located 4"to 6"(102 mm to 152 mm)below the ceiling. cULus FM' NYC LPCB C E 1- 12121 VK305 175 psi 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y,B1X A2Y,B2Z -- -- -- -- Maximum 250 PSI WWP For Light or Ordinary Hazard Occupancies. Deflectors must be located 4"to 12" (102 mm to 305 mm)below the ceiling. cULus4 FM NYC5 LPCB C E 12285 VK319 250 psi 1/2" 15 mm 5.6 80.6 2-11/16 68 A1Y,B1X -- A1Y -- -- -- Approved Escutcheons Approved Temperature Ratings X- Installed with standard surface-mounted escutcheons or A 135°F(57°C),155°F(68°C),175°F Approved Finishes the Viking Microfast® Model F-1 Adjustable Escutcheon', (79 °C), 200 °F (93 °C),and 286°F 1 - Brass, Chrome-Enloy®, White Polyester', or recessed with the Viking Micromatic®Model E-1, E-2 or (141 °C) Black Polyester',and Black TeflonO7 G-1 Recessed Escutcheon B-135°F(57°C),155°F(68°C),175°F 2-Brass Y- Installed with standard surface-mounted escutcheons or (79°C),and 200°F(93°C) the Viking Microfast®Model F-1 Adjustable Escutcheon' Z-Installed with the Viking Model G-1 Recessed Escutcheon Footnotes 1 Base p artnumber shown.For comp letep artnumber,refer to Viking's current p riceschedule. 2 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 3 This table shows the listings and app rovalsavailable at the time of printing.Other app rovalsmay be in process. 'Listed by Underwriters Laboratories Inc.for use in the U.S. and Canada. 'Acceptedfor use, City of New York Departmentof Buildings, MEA 89-92-E,Vol.16. 6 FM App rovecfor installation in accordance with the latest app licableFM Loss Prevention Data Sheets and Technical Advisory Bulletins. 7cULu s Listed as corrosion-resistant. Other colors are available on request with the same Listings and Approvals as the standard colors. The Viking Microfast®Model F-1 Adjustable Escutcheon is considered a surface-mounted escutcheon because it does not allow the fusible element of the sprinkler to be recessed behind the face of the wall or ceiling. February 13, 2009 Sprinkler43e MI R•FA AND MI R'- NII<ING TECHNICAL DATA FASTHR) QUICK RESPONSE HORIZONTAL SIDEWALL SPRINKLERS (VK305&VK319) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-950?Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESIGN CRITERIA (Also refer to the Approval Chart on p age43d.) cULus Listing Requirements: Quick Resp onse Horizontal Sprinklers VK305 and VK319 are cULus Listed as indicated in the App rovaChart for installation in accordance with the latest edition of NFPA 13 for sidewall standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occup ancies. • Locate the deflector 4"to 12" (102 mm to 305 mm)below the ceiling. • Protection areas and maximum sp acing shall be in accordance with the tables provided in NFPA 13. • Minimum sp acing allowed is 6 ft.(1.8 m). • Align the top of the deflector parallel with the ceiling. • Locate no less than 4"(102 mm)from end walls. • Maximum distance from end walls shall be no more than one-half of the allowable distance between sprinklers.The distance shall be measured perpendicularto the wall. • The sprinkler installation and obstruction rules contained in NFPA 13 for sidewall standard sp raysprinklers must be followed. FM Approval Requirements: Install in accordance with the latest app licableFM Loss Prevention Data Sheets (including 2-8N) and Technical Advisory Bulletins. FM Global Loss Prevention Data Sheets and TechnicalAdvisory Bulletins contain guidelines relating to,but not limited to:minimum water sup p lyrequirements,hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing,and deflector distance below the ceiling. NOTE:The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699- Care and Handling of Sprinklers. Also refer to page QR1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD,VdS or other similar organizations,and also with the provisions of governmental codes, ordinances,and standards, whenever applicable. Wall Opening Size: 2-5/16" (58.7 mm) minimum 2-1/2" (63,5 mm) maximum 2-7/16" 2-1/16" 2-11/16" (619 mm) I (52.4 mm) (68.3 mm) Minimum f ( 4 m 1-1/4" .al ..q I llllllllllll � I (31,8 mm) IIIIIIIIIIIIIII� i �l 5m) "ME � 1✓I 1/2" � 1 � � (15 mm) 1 NPT HSW Sprinkler 2-5/8" 12121 (VK305) Pi (66.7 mm) Maximum Installed with a standard 1/8" (3.1 mm) Installed with a Micro-Fast surface-mounted escutcheon Model F-1 Adjustable Escutcheon Figure 3: Sidewall Sprinkler VK305 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Sp rinkler43f February 13, 2009 MICROFAST'AND MICRO- FASTHP5 QUICK RESPONSE \ilium TECHNICAL DATA HORIZONTAL SIDEWALL SPRINKLERS (VK305&VK319) The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-950?Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Wall Opening Size: 2-5/16" (58.7 mm) minimum 2-1/2" (635 mm) maximum 1-5/8" 1 3/4" (41.3 mm) (44,5 mm) I Minimum I Minimum f Fl_ f ,._ 2-1/8" -� -1 2 1/8" -1 -� 7---- . (25-41 54 mm) IIIIIIII g 1 �I �I C54 mm) 111110! VIII 41 �I it 41_60 `�� 1 2-1/4" I 2-5/8" (57.2 mm) (67 mm) Maximum Maximum Installed with a Micromatic Installed with a Model E-2 Model E-1 Recessed Escutcheon Thread on Recessed Escutcheon Figure 4: Sidewall Sprinkler VK305 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Wall Opening Size with the Model G-1 Escutcheon: 2-5/8" (66 mm) minimum 1/8" 3-3/4" (95 mm) maximum ---I f (3.2 mm) Adjustable iL_Fl Adjustable -\ Outer Cup Adapter Ring _ o�31 � a 1�.il�4�MI 2-5/8" 4�� / ��������������.1111—.11 .� i✓ (6 6 mm) (102 mm) �, Depth: 7 _ 1-1/16" (27 mm) 1-1/16"IyL Maximum Recess: (27 mm) 1/2" (12,7 mm) Figure 5: Sidewall Sprinkler VK305 Dimensions with the Model G-1 Recessed Escutcheons Form No. F_030103 Rep lacesp age43a-f,dated March2,2007.(RevisedFM Design Criteria.Added the Model G-1 Escutcheon.) April 24, 2009 Sprinkler105a NIKI TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com 1 . DESCRIPTION Viking Quick Response Dry Pendent Sprinklers are thermosensitive spray sprinklers suit- able for use in areas subject to freezing.The sprinklers are designed for dry systems and preaction systems where it is necessary to prevent water or condensation from enter- ing the drop nipple before sprinkleroperation.They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry Pendent Sprinklersare available in various finishes and temperature ratings to meet design requirements. 2. LISTINGS AND APPROVALS cULus Listed:Category VNIV NYC Approved:MEA 89-92-E Volume 15 Refer to the Approval Chart on page 105d and Design Criteria on page 105d for cULus Listing requirements that must be fol l owed. 3. TECHNICAL DATA Viking Technical Data may be found on Specifications: The Viking Corporation's Web site at Minimum Operating Pressure:7 psi (0.5 bar) http://www.vikinggroupinc.com. Maximum Working Pressure:175 psi(12 bar).Factory tested pneumatically The Web site may include a more recent to 100 psi (6.89 bar) Thread size: 1" NPT edition of this Technical Data Page. Nominal K-Factor: 5.6 U.S. (80.6 metric*)for al I I isted and approved I engths. *Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. GI ass-bulb fluid temperature rated to-65 °F (-55°C) Material Standards: Frame Casting: Brass UNS-C84400 Deflector:Brass UNS-C26000 Bulb:Glass, nominal 3 mm diameter Bel levil leSpring Seal ing Assembly:Nickel Alloy,coated on both sides with Teflon Tape Displacement Ring: Phosphor Bronze UNS-C51000 Compression Screw:Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter:Brass UNS-C36000 Orifice: Copper UNS-C21000 Gasket: Buna-N Tube: ERW Hydraul is Steel Tube Inlet: Brass UNS-C31400 or UNS-C31600 Support(Internal):Brass UNS-C36000 Barrel:Steel Pipe UNS-G10260, El ectrodeposited Epoxy Base finish Barrel Threads: UNS-G10260 SI eeve(for Adjustable Standard style only):Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 Ordering Information:(Also refer to the current Viking price Iist.) Order Quick Response Dry Pendent Sprinklers by first adding the appropriate suffix for the sprinkler finish,the appropriate suffix for the temperature rating,and then the suffix for the I ength("A"dimension) to sprinkler base part number.Order in a specific I ength noted as the"A"dimension (see Figures 3 through 5).The "A"dimension is the distance from the face of the fitting (tee)to the desired finished surface of the ceiling. Form No. F_031793 Replaces page 105a-f, dated February 13, 2009. (Added note regarding CPVC tee fittings.) Sprinkler105b April 24, 2009 TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com These sprinklers are I isted and approved in lengths from 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) for the adjustable standard style,3"to 47" (76.2 mm to 1,194 mm)for the plain barrel style,and 3-1/4"to 47-1/2" (82.5 mm to 1,207 mm)for the adjustable recessed style. Lengths exceeding the standard lengths are available,with no approvals,on a "made-to-order"basis: Recessed Dry Pendent up to 65-1/2" (1,664 mm).Adjustable Standard Dry Pendent up to 63-1/2" (1,613 mm). Plain Barrel Dry Pendent up to 65"(1,651 mm). Contact the manufacturer for more information. Finish Suffix:Brass=A,Chrome-Enloe = F,and White Polyester= M-/W Temperature Suffix(°F/°C): 155°/68° = B, 175°/79° = D,200°/93° = E,286°/141° =G For example,sprinkler VK176 with a Chrome finish and a 155 °F/68 °C temperature rating,and "A"length of 10" = Part No. 08383FB10. Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the"SprinklerAccessories"section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench:Part No. 07297W/B (available since 1991) B.Wrench for recessed sprinklers:Part No. 07565W/B**(available since 1991) **A'/2"ratchet is required(not available from Viking). Sprinkler Guard:Chrome,with no I istings or approvals,for installation on dry pendent sprinklers manufactured after May 1994 only(Part No. 08954). Replacement Escutcheons: A.Adjustable Standard Dry Escutcheon:Base Part No. 07741 B. Recessed Dry Escutcheon Cup: Base Part No. 05459A 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat-sensitive I iquid in the gl ass bulb expands, causing the gl ass to shatter,releasing the internal parts to open the waterway.Water fl owing through the sprinklerorifice strikes the sprinklerdeflector,forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS,TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY11111 wrench The Viking Quick Response Dry Pendent Sprinkler is available through Plat a network of domestic and international distributors. See The Viking Protective im i Corporation web site for the closest distributor or contact The Viking ;;;� Sprinkler Corporation. a°iia 3AON38 Shield V 8. GUARANTEE I��` For details of warranty, refer to Viking's current I ist price schedule orrl`. I1 contact Viking directly. VIKING 07297 Q Figure 1: Standard Sprinkler Wrench 07297W/B April24, 2009 Sprinkler 105c VIKING TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature prinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 155 °F (68 °C) 100 °F (38 °C) Red Intermediate 175 °F (79 °C) 150 °F (65 °C) Yellow Intermediate 200 °F (93 °C) 150 °F (65 °C) Green High j 286 °F (141 °C) 225 °F (107 °C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®(patents pending), and White Polyester Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13. Other limits may apply,depending on fire loading, sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards.IlSprinkler Wrench 07565W/B** must be used for installing recessed dry sprinklers iiNI I U Ali.1 m1 1. 1��mm.j. iffy, nil ll i '111111! Step 1: Carefully slide the wrench ; sideways around the ' i sprinkler deflector. M Step 2: Carefully press the wrench upward and f ?EA 1/2" ratchet is required, turn slightly to ensure (Not available from Viking.) engagement with the sprinkler wrench flats. Figure 2: Wrench 07565W/B for Adjustable Recessed Dry Pendent Sprinklers Sprinkler105d April 24, 2009 NIIIUNG TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Approval Chart Temperature KEY Quick Response Dry Pendent Sprinklers �,fr—Finish Maximum 175 PSI(12 bar)WWP A1X4Escutcheon(if applicable) Sprinkler Thread Size Nominal Order Length Listings and Approvals" Base Part SIN Style K-Factor2 Increment (Refer also to Design Criteria below.) Number NPT BSP U.S. metric' Inches mm cULus5 FM NYCE VdS LPCB CE 0 08383 VK176 Adjustable 1" -- 5.6 80.6 1/2" 12.7 Al -- Al -- Standard 08385 VK180 Adjustable 1" -- 5.6 80.6 1/4" 6.35 B2 -- B2 -- Recessed 08387 VK172 Plain 1" -- 5.6 80.6 1/2" 12.7 A3 -- A3 -- Barrel Approved Temperature Ratings Approved Finishes and"A"Dimensions A- 155 °F (68 °C), 175 °F (79°C), 200 °F (93 °C), 1 - Chrome-Enloe' or White Polyester sprinkler with a Chrome-Enlo9 or White Polyester and 286 °F(141 °C) Sleeve and Escutcheon with"A"dimensions 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) 2-Chrome-Enloy®or White Polyester with"A"dimensions 3-1/4"to 47-1/2" (82.5 mm to 1,207 mm) B- 155°F(68°C),175°F(79°C),and 200°F(93°C) 3-Chrome-Enl off"or Brass with"A"dimensions 3"to 47"(76.2 mm to 1,194 mm) Footnotes 1 Part number shown is the base part number.For complete part number,refer to current Viking price I ist schedule. 2 K-Factor appl ies for standard I engths("A"Dimensions indicated above). 3 Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. 'This chart shows the I istings and approvals avail abl eat the time of printing. Other approvals may be in process. Check with the manufacturer for any additional approvals. Listed by Underwriter's Laboratories for use in the U.S.and Canada. 6 Accepted for use, City of New York Department of Buil dings, MEA Number 89-92-E,Vol.15. DESIGN CRITERIA I I (Al so refer to the Approval Chart above.) NOTE:When using CPVC fittings with Viking dry sprinklers, use only new Nibco Model 5 012-S-Bl tees.When selecting other CPVC fittings, contact Viking Technical Services. cULus Listing Requirements: Standard Dry Pendent Sprinklersare cULus Listed as indicated in the Approval Chart for instal lationin accordance with the latest edition of NFPA 13 for standard spray sprinklers. • Designed for use in Light and Ordinary Hazard occupancies. • The sprinkler installation and obstruction rules contained in NFPA 13 for standard spray pendent sprinklers must be fol lowed. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page DRY1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA,FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards,whenever applicable. April 24, 2009 Sprinkler 105e NIIKING TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com For "A" Dimension: 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2" (12,7 mm) between 1-1/2" and 45-1/2" (38.1 mm and 1,156 mm). NOTE: The deflector will be located approximately 3-7/16" (87.3 mm) below the ceiling. with 1" (25.4 mm) upward and 1" (25.4 mm) downward adjustment, Deflector at minimum distance below ceiling. /.UUIII1 NOTE: To locate the deflector jllll�� at the minimum distance � below the ceiling, with I I I no downward adjustment Minimum ceiling opening W-7/16" available, order the A (61.9 mm) dry pendent sprinkler diameter: 1-3/4" (44.5 mm), I Minimum Maximum ceiling opening �, 1" (25.4 mm) shorter diameter: 2-1/4" (57 mm). than the "A" dimension, l. (1 111Mr 13/16" 1=1 NOTE: Finished — (20.6 mm) JILIPPP To locate the deflector Ceiling at the maximum distance 4-7/16" below the ceiling, with 1-1/2" /TSleeve finish (112.7 mm) no downward adjustment (38.1 mm) I. matches escutcheon. Maximum available, order the diameter _I dry pendent sprinkler 3-1/16" I 1" (25.4 mm) longer (77.8 mm) than the "A" dimension. Deflector at maximum distance below ceiling. Figure 3: Adjustable Standard Dry Pendent Sprinkler MII'S $ ��-i For "A" DimensioneargikUIIIO } 1. Determine the distance from face of tee to � A the finished ceiling. %— 2. Round to nearest 1/'l T'For "A" Dimension (6.35 mm) between mmEmmm 3-1/4" (82.5 mm) and A 1. Determine the Minimum ceiling opening: 47-1/2' (1,207 mm) distance from 2-1/8" (54 mm) diameter, ❑utside the face of the NOTE: Sprinkler will be diameter: tee to the base recessed approximately 1-5/16" of the sprinkler. Maximum ceiling opening: PP Y 2-1/2" (63.5 mm) diameter, 5/16" (7.9 mm) above (33.4 mm) 2. Round up to the the finished ceiling with (same as 1" next highest 1/2" (25 mm) (12.7 mm) incre- 5/8" (15.8 mm) vertical Schedule ment between 3" adjustment available. 40 pipe). (76.2 mm) and Ad justment: T 47" (1,194 mm). 5/16" (7,9 mm)- C== 1 L T .. 5/16" (7.9 mm) 111 C--1---- Finished ceiling 1-5/8" Minimum: � N � (48.3 mm) 1" (25.4 mm) —_ 1 ir Maximum: 3-1/16" 1-5/8" (42,1 mm) — _ 77,9 mm) Figure 4: Adjustable Recessed Dry Pendent Sprinkler Figure 5: Plain Barrel Dry Pendent Sprinkler Sprinkler 105f April 24, 2009 NIKING TECHNICAL DATA QUICK RESPONSE DRY PENDENT SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com For "A' Dimension; 1. Determine the distance from the face of the tee to the finished ceiling. 2. Round to the nearest 1/2" (12,7 mm) between 1-1/2" and 45-1/2" (38.1 mm and 1,156 mm). NOTE; The deflector will be located approximately 3-7/16' (87.3 mm) below the ceiling. with 1' (25.4 mm) upward and 1' (25.4 mm) downward adjustment. Deflector at minimum / Install 1 inch NPT threaded distance below ceiling. end of dry pendent sprinkler g. into the 1 Inch NPT outlet Minimum Recommended■ �'DDI�I00��of a malleable Iron tee fitting NOTE; Temperature Distance From per ANSI B 16,3 (Class 150) or cast Iron threaded tee fitting I, To locate the deflector In Face of Tee to 601 per ANSI 16,4 (Class 125) only. Freezer Top of Freezer /•==_Y , at the minimum distance -20 °F 12 inches Minimum ceiling opening diameter; 1 below the ceiling, with (-29 °C) (300 mm) 1-3/4' (44,45 mm) -7/16' no upward adjustment / Maximum ceiling opening diameter; (61,9 mm) available, order the dr) -40 °F 18 Inches 2-1/4' (57 mm). I Minimum (-40 °C) (450 mm) N I pendent sprinkler 1' (25.4 mm: -50 °F 2a inches / Seal the clearance space shorter than the "A" around the sprinkler barrel (a51 trp a I I to avoid leakage air se- 93=-933111133=331333331 IMFFIMI dimension. x Based on industrypractice the freezer area and conse- 13/16' quent formation of condensate NOTE; I/ _NEW (20,6 mm) around the sprinkler frame, Freezer Ceiling J which could Inhibit operation To locate the deflector or cause premature operation. 4-7/16' at the maximum distance , Ref to Figure 7 below, (112,7 mm) below the ceiling, with Sleeve finish 1-1/2' (38,1 mm)- 'I' matches If humidity and temper- Maximum no upward adjustment diameter escutcheon condensation on the ature differential causes available, order the dr) -. exposed dry sprinkler I pendent sprinkler 1' (25,4 mm; 3-1/16' barrel, consider wrapping longer than the 'A" (77,8 mm) the exposed barrel with Deflector at maximum Insulation, foam Insulating dimension, tape, or equivalent. distance below ceiling. Figure 6: Dry Pendent Sprinkler Installation in Freezers(Adjustable Standard Dry Pendent Sprinkler is Shown) I • Seal (or equivalent method) Seal _ mr . . J',W WI r�������������iA.. . r /���������������A I�������������������A Clearance ® Insulated Opening Freezer Structure I• Im_ Dry Sprinkler Seal on Exterior of' Freezer Dry Sprinkler Seal Within Freezer Figure 7: Dry Sprinkler Seal(Adjustable Standard Dry Pendent Sprinkler is Shown) Form No. F_031793 Replaces page 105a-f, dated February 13, 2009. (Added note regarding CPVC tee fittings.) Page 1 of 8 QUICK RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com 1 . DESCRIPTION Viking Quick Response Dry Horizontal Sidewall Sprinklers are thermosensitive spray sprinklerssuitabl e for use in areas subject to freezing. The sprinklersare1111 C designed for dry systems and preaction systems where it is necessary to prevent water or condensation from entering the drop nipple before sprinkler operation. They may also be installed in spaces subject to freezing and supplied from a wet system in an adjacent heated area. Viking Quick Response Dry HSW Sprinklers are available in various finishes -`3rf and temperature ratings to meet design requirements.The special Polyester and El ectrol ess Nickel PTFE (ENT) coatings have been investigated for installation in corrosive atmospheres and are I isted/approved as corrosion resistant as indi- cated in the Approval Charts. (Note: FM Global has no approval classification for �I�N��•i Polyester coatings as corrosion resistant.) NOTE:When installed in some corrosive environments,the Polyester finish II may change color.This natural discoloration over time is not in itself an indi- cation of corrosion and should not be treated as such.All sprinklers installed For Light Hazard Occupancies Only in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV US FM Approved:Classes 2013 and 2015 FM NYC Approved:MEA 89-92-E, Volume 15 Refer to Approval Chart 1 and Design Criteria on page 106c for cULus Listing requirements,and refer to Approval Chart 2 and Design Criteria on page 106d for FM Approval requirements that must be fol lowed. 3. TECHNICAL DATA Specifications: Available since 1993. Minimum Operating Pressure:7 psi (0.5 bar) Maximum Working Pressure:175 psi(12 bar). Factory tested pneumatically to 100 psi (6.89 bar) Thread size: 1" NPT or 25 mm BSP Nominal K-Factor: 5.6 U.S. (80.6 metric*)for al I I isted and approved lengths. *Metric K-factor measurement shown is when pressure is measured in Bar.When pressure is measured in kPa,divide the metric K-factor shown by 10.0. GI ass-bulb fluid temperature rated to-65 °F (-55°C) Covered by the fol lowing U.S. Patent numbers:8,636,075 and 8,376,060 Viking Technical Data may be found on Material Standards: The Viking Corporation's Web site at Frame Casting: Brass UNS-C84400 http://www.vikinggroupinc.com. Deflector:Phosphor Bronze UNS-C51000 The Web site may include a more recent Bul b:Glass, nominal 3 mm diameter edition of this Technical Data Page. BellevilleSpring Sealing Assembly: Nickel Alloy,coated on both sides with PTFE Tape Compression Screw:Brass UNS-C36000 Pip Cap: Brass UNS-C31400 or UNS-C31600 Pip Cap Adapter:Brass UNS-C36000 Orifice: Copper UNS-C22000 or UNS-C11000 Tube: ERW Hydraul is Steel Tube Support(Internal):Stainless Steel UNS-S30400 Barrel:Steel Pipe UNS-G10260, El ectrodeposited Epoxy Base finish Barrel End and Threads: QM Brass SI eeve(for Adjustable Standard style only):Brass UNS-C26000 or UNS-C26800 Escutcheon Materials: Adjustable Standard Dry Escutcheons: Brass UNS-C26000 or UNS-C26800 Recessed Dry Escutcheons: Cold Rolled Steel UNS-G10080 ENT Coated Adjustable and Recessed Escutcheons: Stainless Steel UNS-530400 Ordering Information:(Also refer to the current Viking price I ist.) Order QR Dry HSW Sprinklers by first adding the appropriate suffix for the sprinkler finish,the appropriate suffix for the temperature rating, and then the suffix for the length("A"dimension) to sprinkler base part number.Order in a specific length noted as the"A"dimension.The "A"dimension is the distance from the face of the fitting(tee)to the desired finished surface of the wall in which it is tobe instal I ed. Form No. F_031993 Rev 15.1 Page 2 of 8 NimNoTh QUICK RESPONSE TECHNICAL DATA DRY HORIZONTAL SIDEWALL SPRINKLERS The Viking Corporation, 210 N Industrial Park Drive,Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax:269-818-1680 Email:techsvcs@vikingcorp.com These sprinklers are listed and approved in lengths from 1-1/2" to 45-1/2" (38.1 mm to 1,156 mm) for the adjustable standard style,3"to 47" (76.2 mm to 1,194 mm)for the plain barrel style,and 3-1/4"to 47-1/2" (82.5 mm to 1,207 mm)for the adjustable recessed style. Lengths exceeding the standard lengths are avail abl e,with no approvals, on a"made-to-order" basis: Recessed Dry HSW up to 65- 1/2" (1,664 mm).Adjustable Standard Dry HSW up to 63-1/2" (1,613 mm). Plain Barrel Dry HSW up to 65"(1,651 mm). Contact the manufacturer for more information. Finish Suffix:Brass=A,Chrome= F,White Polyester= M-/W,and ENT= JN Temperature Suffix:155 °F (68 °C) = B, 175 °F (79°C) = D,200 °F (93°C)= E, 286 °F (141 °C) = G Escutcheon Suffix = Y for the adj. recessed sprinkler with the Model G-1 Escutcheon (no suffix needed for the Model E-1 Escutcheon). NOTE Sprinkler is turned s deways For example,sprinklerVK182 with 1" NPT Threads, a Chrome finish,a 155 for clarity 'Pefer to Figures 2-7 ) °F(68°C)temperature rating,the Model G-1 Escutcheon,and "A"length co��ec oefector osientGtlon of 10" = Part No. 08386UFBY10. Protect Available Finishes And Temperature Ratings:Refer to Table 1. Sprinkle Accessories: (Also refer to the"Sp rinklerAccessories"section.) Shield Sprinkler Wrenches: A.Standard Wrench:Part No. 07297W/B (available since 1991) B.Wrench for recessed sprinklers:Part No.07565W/B**(available since 1991) 1110 ■ **A/2"ratchet is required(not available from Viking). 1 — IN Dry Sprinkler Protective Cover:Part No. 15610 Replacement Escutcheons: A.Adjustable Standard Dry Escutcheon:Base Part No. 08086F Wrench B. Model E-1 Recessed Dry Escutcheon Cup: Base Part No. 05459A Flat 4. INSTALLATION Refer to appropriate NFPA Installation Standards. \=- 5. OPERATION VIKING x729' O During fire conditions, the heat-sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the internal parts to open the water- way.Water flowingthrough the sprinkler orifice strikes the sprinkler deflector, Figure 1: forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS,TESTS AND MAINTENANCE Standard Sprinkler Wrench 07297W/B Refer to NFPA 25 for Inspection,Testing and Maintenance requirements. 7. AVAILABILITY The Viking Quick Response Dry Horizontal Sidewal I Sprinkler is avail abl ethrough a network of domestic and international distribu- tors.See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current I ist price schedule or contact Viking directly. TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES Sprinkler Temperature Sprinkler Nominal Maximum Ambient Bulb Color Classification Temperature Rating' Ceiling Temperature2 Ordinary 155 °F (68 °C) 100 °F (38°C) Red Intermediate 175 °F (79 °C) 150 °F (65°C) Yellow Intermediate 200 °F (93°C) 150 °F (65°C) Green High 286 °F(141 °C) 225 °F (107 °C) Blue Sprinkler Finishes:Brass, Chrome,White Polyester,and ENT Corrosion-Resistant Coating3,4: White Polyester and ENT in al I temperature ratings Footnotes 1 The sprinkler temperature rating is stamped on the deflector. 2 Based on NFPA-13.Other I imits may apply,depending on fire loading,sprinkler location,and other requirements of the Authority Having Jurisdiction. Refer to specific instal I ation standards. 3 The corrosion-resistant Polyester and ENT coatings have passed the standard corrosion test required by the approving agencies indi- cated in the Approval Charts.These tests cannot and do not represent all possible corrosive environments.Note: These coatings are NOT corrosion proof. Prior to installation,verify through the end-user that the coatings are compatible with or suitable for the proposed environment. Polyester and ENT coatings are applied to the exposed exterior surfaces only.Note that the spring is exposed on sprinklers with Polyester and ENT coatings. 4 When installed in some corrosive environments,the Polyester finish may change color.This natural discoloration over time is not in itself an indication of corrosion and should not be treated as such.All sprinklers installed in corrosive environments should be replaced or tested as described in NFPA 25 on a more frequent basis. Form No. F_031993 Rev 15.1