HomeMy WebLinkAboutE18-0081_ANTLERS 702 LOAD CALC_1525455285.pdf S � C
wirg• 44,b
ANTLER702 LOAD CALCULATION °
PREPARED BY NICK LUNN OF COBALT ELECTRIC 05/04/18
970-309-7054
Project Name: Antlers 702
Project Type: One-Family Dwelling
Phases Ampacity:70 A
Neut ral Ampacity (derated): 36 A
Service Voltage: 240 V Single Phase
Total Phases Load: 16693 VA
Total Neutral Load: 8698 VA
General Lighting
(Table 220.12)
Area: 660 sq ft
Small Appliances: 1500 VA
l' ill
S C
Nuf
tib, ,4
Number of Circuits: 2 -/Q03
Laundry: 1500 VA 05/04/18
Totals:
Phases: 4218 VA
Neutral: 4218 VA
Fixed Appliances
(220.53)
Dishwasher: 1200 VA
Neutral: No
Disposer: 900 VA
Neutral: No
Compactor: 0 VA
Neutral: No
Water Heater: 0 VA
Neutral: No
Electric Baseboard Heat : 6000 VA
Neutral: No
Totals:
l' ill
S C
Phases (derated): 6075 VA ,
Neutral (derated): 0 VA 05/04/18
Dryer
(220.54; Table 220.54)
Dryers (Sum Total): 0 VA
Number of Dryers: 0
Totals:
Phases (derated): 0 VA
Neutral (derated): 0 VA
Cooking Equipment
(220.55; Informational Notes)
Column A (Sum Total): 0 VA
Number of Appliances (Column A): 0
Column B (Sum Total): 8000 VA
Number of Appliances (Column B): 1
Column C (Sum Total): 0 VA
Sill C
wirg• 44,b
Number of Aliances (Column C : 0 °,
pp ) -/Q03-0
05/04/18
Totals:
Phases (derated): 6400 VA
Neutral (derated): 4480 VA
Heating or A/C
(220.60)
Heating Unit : 0 VA
A/C Unit : 0 VA
Heat Pump: 0 VA
Totals:
Phases: 0 VA
Neutral: 0 VA
Largest Motor
(220.14)
Largest Motor: Enter Largest Motor Name
Sill C
Phases: 0 VA -
Neutral: 0 VA 05/04/18
Totals:
Phases (derated): 0 VA
Neutral (derated): 0 VA
This E-mail was generated on 5/2/2018 using the Electrical Load Calculator by
American Technical Publishers, Inc.