Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A18-0044_approved documents_1533672974.pdf
75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspections: inspections@vailgov.com Fire - Construction Permit A18-0044 Issued: 08/07/2018 TOWN OF VAIL Property Information Address: 44 W MEADOW DR 6 ( 210107116006 ) Unit #: 6 Parcel Number: 210107116006 Legal Description: Subdivision: MEADOW VAIL PLACE CONDO Unit: 6 BK-0437 PG-0075 SWD 09-01-85 R785446 WD 12-17-01 R871732 QCD 12-23-03 Contacts Contact Type: Applicant Full Name: Baron Ferguson Address: 303 County Road 265 PO Box 883 Rifle, CO 81650 Phone: 9709895347 Contact Type: Applicant Full Name: Clint Bartels Address: PO Box 883 303 County Road 265 Rifle, CO 81650 Phone: 9706253398 Contact Type: Property Owner Full Name: MAIA REALTY LIMITED Address: 44 W MEADOW DR 6 VAIL, CO 81657-5705 Phone: None Contractor Contractor Type: Alarm Company: Acme Alarm Company State License #:Phone: 970-625-3398 Project Information Project Name: Maia Realty Limited 2018 Project Description: Fire Alarm Remodel Fees Paid Account #: 001-0000.31111.00 - Fire Alarm Permit Fee Fee Amount:$131.25 Account #: 001-0000.31123.00 - Fire Alarm Review Fee Fee Amount:$288.00 Total Paid:$419.25 Conditions Issued By: Town of Vail Fire and Emergency Services Department NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. FIRE ALARM PERMIT Commercial and Residential Fire Alarm shop drawings are required at the time of application submittal and must included information listed on the 2nd page of this form. Application will not be accepted without this information. Contractor Information: Company: _____________________________________________ Company Address: ______________________________________ City: ____________________ State: _______ Zip:_____________ Contact Name: _________________________________________ Contact Phone: _________________________________________ E-Mail ________________________________________________ I hereby acknowledge that I have read this application, filled out in full the information required, completed an accurate fire alarm sys- tem drawings and state that all the information as required is cor- rect. I agree to comply with the information and fire alarm system drawings, to comply with all Town ordinances and state laws, and to build this structure according to the towns zoning and subdivision codes, design review approval, National Fire Code, International Building and Residential Codes and other ordinances of the Town applicable thereto. X___________________________________________________ Contractor Signature (required) Project Street Address: __________ ______________________________ ___________ (Number) (Street) (Suite #) Building/Complex Name: ________________________________ Property Information Parcel #: ______________________________________________ (For parcel #, contact Eagle County Assessors Office at 970-328-8640 or visit www.eaglecounty.us/patie) Tenant Name: __________________________________________ Owner Name: __________________________________________ Complete Valuation for Fire Alarm Permit: Fire Alarm $: __________________ Office Use: Project #: ________________________________________ Building Permit #: _________________________________ Alarm Permit #: ___________________________________ Lot #: ____ Block # ____ Subdivision: __________________ Detailed Scope and Location of Work: ________________ ________________________________________________ ________________________________________________ ________________________________________________ (use additional sheet if necessary) Work Class: New ( ) Addition ( ) Remodel ( ) Repair ( ) Retro-Fit ( ) Other ( ) Type of Building: Single-Family ( ) Duplex ( ) Multi-Family ( ) Commercial ( ) Restaurant ( ) Other ( ) Date Received: Does a Monitored Fire Alarm Exist? Yes ( ) No ( ) Does a Sprinkler System Exist? Yes ( ) No ( ) 13-Apr 01 Fire and Emergency Services 2399 N. Frontage Road W. Vail, Colorado 81657 Tel: 970-479-2252 www.vailgov.com Fire Marshall 44 West Meadow Drive 6 Meadow Vail Place Acme Fire Alarm Company Po Box 883 Rifle CO 81650 Baron Ferguson 970-989-5344 baron@acmealarm.com Fire Department Process For Commercial & Residential Fire Alarm Systems Commercial and Residential Fire Alarm shop drawing requirements at the time of submittal must include the following: __________ A Colorado Registered Engineer’s stamp __________ Device locations on reflected ceiling plans __________ Reflected Ceiling Plans (RCP) __________ Typical device wiring diagrams __________ Battery calculations __________ Battery calculations __________ A list of specific device model numbers __________ Equipment cut sheets of each type of device __________ The number of each type of device __________ Information indicating the specific zones __________ Circuit diagrams __________ Point to point wiring diagram __________ Wiring type, size and number of conductors __________ The source of AC power circuits __________ Fire alarm panel locations __________ Knox Box location __________ Information indicating monitoring method and monitoring agency This check list has been provided to ensure that our review process may be handled in a timely manner. I have read and understand the above listed submittal requirements: Project/Street Address: _______________________________________________________ Contractor Signature: _______________________________________________________ Date Signed: _______________________________________________________ 01-feb-10 Fire Department Guidelines For Preventing Non-Emergency Fire Alarms In order to prevent a non-emergency response from the Vail Fire Department Suppression crews to the con- struction location you may be working on, we ask that you perform the following tasks: Please contact the Vail Fire Department at 479-2252. I have read and understand the above listed submittal requirements: Project/Street Address: _______________________________________________________ Contractor Signature: _______________________________________________________ Date Signed: _______________________________________________________ __________________ Determine what kind of fire alarm system exists within the structure you are working in with the owner or the manager of the property involved or by contact- ing the Vail Fire Department. __________________ Determine with the owner or manager of the property, which alarm company services the system for them __________________ Become familiar with the different components that are associated with the fire alarm system and how they operate before the DEMO begins. __________________ Never paint a smoke detector, thermal detector, or any other component of the fire alarm system and never paint a sprinkler head/cover plate. __________________ For larger projects, please contact the Vail Fire Department so that we can work with you in determining what needs to be done to alter or “Zone Out” spe- cific areas of the alarm system for the structure. 01-R3g-10 Fire Department Guidelines Pre-Plan Information Sheet BUILDING INFORMATION: Building Name: _______________________________________________________ Street Address & Phone #: _______________________________________________________ Knox Box Location: _______________________________________________________ Alarm Panel Location: _______________________________________________________ Vail Fire & Emergency Services Alarm Silence & Rest Codes: _______________________________________________________ RPS’: Names & Phone Numbers (Work & Home) Owner: _______________________________________________________ Property Manager: _______________________________________________________ Property Maintenance Mgr: _______________________________________________________ Alarm Service Company: _______________________________________________________ BUILDING UTILITIES: Gas: Main Location: _______________________________________________________ Other Locations: _______________________________________________________ Electric: Main Location: _______________________________________________________ Other Locations: _______________________________________________________ Water: Main Valve Location: _______________________________________________________ Main Fire Valve Location: _______________________________________________________ Secondary Fire Valve Loc: _______________________________________________________ 01-Feb-10 Instructions for calculating FIRE ALARM or SPRINKLER permit fees (see applicable section below): 1. Determine the valuation (labor & materials) 2. See base Permit Fee (flat fee) 3. Calculate the Plan review fee (multiply the valuation by the applicable percentage listed) Fire Alarm: Permit Fee: 3.75% of the valuation Plan Review Fee: $288.00, due at permit submittal Fire Sprinkler: Permit Fee: 4.25% of the valuation Plan Review Fee: $432.00, due at permit submittal OTHER Fire Permit Fees: • Permits issued under a Scope of Work letter shall be assessed a fee not less than $144.00 and may be increased at a rate of $72.00 per hour for inspections, revisions, and similar elements. • Re-inspections and plan review for re-submittals shall be billed at $72.00 per hour. • Operational Permits, Special Event Permits, and Construction Permits other than those required for Fire Alarm and Fire Sprinkler systems, issued under provisions of the International Fire Code shall be based on an hourly rate of $72.00 per hour per person for site inspections, plan review and permit processing. Town of Vail Fire Permit Fee Schedule • IDP-Photo Photoelectric Smoke Detector • IDP-Photo-T Photoelectric Smoke Detector with Thermal • IDP-Ion Ionization Smoke Detector • IDP-Acclimate Multicriteria Photoelectric Smoke Detector • IDP-Heat Fixed Temperature Thermal Detector • IDP-Heat-ROR Rate-of-Rise Detector with Thermal • IDP-Heat-HT Fixed High Temperature Thermal Detector • IDP-FIRE-CO Multi-Criteria CO and Smoke Sensor The B200S/B200S-LF are compatible with the following FACPs: • IFP-2000/RPS-2000 Intelligent Fire Panel • IFP-2000ECS Emergency Communication System with Fire Alarm Control Panel • IFP-1000 Intelligent Fire Panel • IFP-1000ECS Emergency Communication System with Fire Alarm Control Panel • IFP-100 Intelligent Fire Panel • IFP-100ECS Emergency Communication System with Fire Alarm Control Panel P/N 351564 Rev B Copyright © 2015 Honeywell International Inc. Intelligent Sounder Bases B200S/B200S-LF The B200S sounder base series is designed for new and existing commercial dwelling unit applications. It offers maximum flexibility in installation, configuration, and operation to meet or exceed UL 268 and UL 464 requirements. The sounder base “listens in” to the communication between the attached sensor head and the fire alarm control panel (FACP) to adopt the same address as the detector, but as a unique device type on the loop. The FACP can then use that address to command an individual sounder — or a group of sounders — to activate. In addition, the FACP’s will enable custom tone patterns. The B200S series sounder bases recognize the System Sensor synchronization protocol. This enables it to be used as a component of the general evacuation signal — along with other System Sensor horns, horn strobes, and chimes — when connected to a FACP output programmed as sounder base power. The B200S-LF low frequency sounder base is designed to meet the NFPA 72 sleeping space requirement to produce a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent. Studies show that a lower frequency, centered around 520 Hz, is the most ideal to awaken sleeping occupants, even those with mild to severe hearing loss. Features • Addressability for maximum configuration flexibility • Supports Continuous, ANSI Temporal 3, ANSI Temporal 4, and March Time tones • Custom tone capability with some FACP models • Ability to synchronize with other System Sensor notification devices • UL 268 and UL 464 compliant • Pre-wire mounting plate fits various junction box sizes • Uses a mechanical locking feature that prevents the removal of the attached sensor head • No external relays and input modules needed to supervise the Aux power • 520 Hz +/– 10% square wave tone (B200S-LF ) Installation The B200S series sounder bases can be mounted directly to 4” (10.16 cm) square, 4” (10.16 cm) octagon, 3 1/2” (8.9 cm) octagon, single-gang or double-gang junction boxes. Compatibility The B200S series are compatible with the following IDP- series detectors programmed for System Sensor protocol: (Firmware version 13.0 or higher for IFP-100 & IFP-1000. (Firmware version 4.0 or higher for IFP-2000). Agency Listings Pending B200SB200S-LF Specifications Physical Height: 2.0” (5.08 cm) less sensor Width: 6.875” (17.46 cm) Shipping Weight: B200S - .50 lb. (227gm) B200S-LF - .60 lb. (272gm) Electrical Aux Power Voltage 16 to 33 VDC (VFWR) Aux Power Standby Current B200S .50 mA maximum Aux Power Standby Current B200S-LF .55 mA maximum Aux Power Alarm Current B200S 35 mA maximum Aux Power Alarm Current B200S-LF 140 mA maximum SLC Operating Voltage 15 to 32 VDC SLC Standby/Alarm Current 300 µA max (base only) Environmental Operating Temperature: 32ºF – 120ºF (0ºC – 49ºC) Humidity: 10% – 93% non- condensing Sound Output Volume Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet, 24 Volts (in continuous tone). Ordering Information B200S Intelligent Sounder Base B200S-LF Intelligent Low Frequency Sounder Base M02-04-01 Detector Test Magnet M02-09-01 Telescoping Test Magnet Wiring B200S/B200S-LF This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Technical Support, Please call 800-446-6444. www.farenhyt.com Compatibility The IDP-FIRE-CO is compatible with the following FACPs programmed for System Sensor protocol: (Firmware version 12.0 or higher) • IFP-1000 Intelligent Fire Panel • IFP-1000ECS Emergency Communication System with Fire Alarm Control Panel • IFP-100 Intelligent Fire Panel • IFP-100ECS Emergency Communication System with Fire Alarm Control Panel • IFP-50 Intelligent Fire Panel P/N 351180 Rev A Copyright © 2012 Honeywell International Inc. Advanced Multi-Criteria Fire/CO Detector IDP-FIRE-CO The IDP-FIRE-CO is a plug-in, addressable device that provides both fire and carbon monoxide (CO) detection. For fire, the detector combines four separate sensing elements in one unit (smoke, CO, light/flame, and heat) to sense multiple components of a fire. This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulate. For CO, the detector’s electrochemical sensing cell creates a separate signal for life safety CO detection. Released through the incomplete burning of various fuels, CO is a colorless, odorless and deadly gas that is virtually impossible to detect with the human senses. Because the potential exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to increase across the U.S. and Canada. The IDP-FIRE-CO is listed to the UL 2075 standard for system-connected life safety carbon monoxide monitoring. The IDP-FIRE-CO should be used in conjunction with the B200S intelligent sounder base (sold separately), which can generate either a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm indication. With each sounder base carrying a unique address, the FACP can then command an individual sounder, or a group of sounders, to activate. The command set from the panel can be tailored to the specific event, allowing selection of tone, and group. For more information on the B200S refer to Data Sheet P/N 351182. Features • Unique ability to detect all four major elements of a fire: - Smoke - Carbon Monoxide (CO) - Light/flame - Heat • Separate CO detection signal • Highest nuisance alarm immunity • Automatic drift compensation of smoke sensor and CO cell • Uses only one address on the SLC • RealTest® CO testing capability • UL 268 and UL 2075 listed • Separates audible signal for fire or CO alarm when used with B200S base • CO cell end-of-life warning and fault IDP-FIRE-CO installed in a B200S Sounder Base (sold separately) Agency Listings Specifications Physical Diameter: 6.875” (17.46 cm) installed in a B200S base Height: 3.46” (8.79 cm) installed in B200S base Shipping Weight: 4.6 oz Color: Ivory Operating Temperature Range: 32° F to 100° F (0° C to 38° C) Humidity: 15 to 90% relative humidity (non-condensing) Air Velocity: 0 to 4,000 ft/min (0 to 20 m/sec) Electrical Operating Voltage: 15 to 32 VDC Maximum Standby: 300µA at 24 VDC (no communication every 5 seconds with LED blink enabled) Maximum Alarm Current (LED on): 7.2 mA at 24 VDC Sensitivity Settings Sensitivity settings are programmable through zone programming. Low: 4% per foot (30.48 cm) of smoke. Used in equipment rooms, kitchens, paint shop. Medium: 3% per foot (30.48 cm) of smoke. Moderately clean environments: Used in hotel rooms, dorm rooms. High: 2% per foot (30.48 cm) of smoke. Clean environments: Used in offices. Warning: After the CO cell has reached the end-of-life, the CO sensor no longer provides life safety protection. However, when the fire detector enters Photo, Thermal, Infrared (PTIR) mode, the following sensitivities apply: Level 1: 1% per foot (30.48 cm) of smoke. Very clean environments- Used in laboratories. Level 2: 2% per foot (30.48 cm) of smoke. Clean environments - offices. Level 5: 3% per foot (30.48 cm) of smoke. Moderately clean environments- Used in hotel rooms, dorm rooms. Level 6: Thermal alarm at 135° F (57° C). CO Monitoring UL Standard Reference - Alarm Thresholds are as follows: Note: Per UL Standard 2075, the IDP-FIRE-CO has been tested to the sensitivity limits defined in UL Standard 2034. Ordering Information IDP-FIRE-CO Multi-Criteria CO Detector Note: Due to the unique nature of this detector, please consult your Fire Alarm Control Panel Manufacturer for the specific model and compatibility. Accessories B200S Intelligent Sensor Sounder Base M02-04-01 Detector Test Magnet M02-09-01 Telescoping Test Magnet Parts Per Million Detector Response Time 70 ± 5 ppm 60-240 min. 150 ± 5 ppm 10-50 min. 400 ± 10 ppm 4-15 min. Made in the U.S.A. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. For Techincal Support, Please call 800-446-6444. www.farenhyt.com Installation The IDP-Photo and IDP-Photo-T plug into a compatible IDP-series detector base. Compatibility The IDP-Photo and IDP-Photo-T are compatible with the following IDP-series detector bases: B210LP 6 Mounting Base B501 4 Mounting Base B224BI 6 Isolator Base B224RB 6 Relay Base B200SR 6 Sounder Base The IDP-Photo and IDP-Photo-T are compatible with the following FACPs: IFP-2000 / RPS-2000 Intelligent Fire Panel IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel IFP-25 Intelligent Fire Panel P/N 350280 Rev E Copyright © 2011 Honeywell International Inc. Intelligent Photoelectric Smoke Detector & Photoelectric Smoke with Thermal IDP-Photo, IDP-Photo-T and IDP-PhotoR The IDP-Photo is a photoelectric smoke detector and the IDP-Photo-T is a photoelectric smoke detector with thermal. These plug in smoke detectors, with integral communication, provide features that surpass conventional detectors and are for use with Silent Knight IFP-series fire alarm control panels (FACPs). Detector sensitivity can be programmed from the FACP software. Sensitivity is continuously monitored and reported to the FACP. Point ID capability allows each detectors address to be set with rotary address switches, providing exact detector locations for selective maintenance when chamber contamination reaches unacceptable levels. IDP-Photo and IDP-Photo-T have a unique optical sensing chamber that is engineered to sense smoke produced by a wide range of combustion sources. In the IDP-Photo-T, dual electronic thermistors add 135ºF (57ºC) thermal technology to maximize detection. The IDP-PhotoR is a remote test capable detector for use with the DNR (W) duct smoke detectors. Features Sleek, low-profile design Reliable analog communications for trouble-free operation Age resistant polymer housing Dual electronic thermistor design on the IDP-Photo-T Superior EMI resistance for reliability Simple field cleaning for code compliance Variety of mounting options to meet any application Dual LED indicators for 360º visibility Detector transmits signal to indicate maintenance is required Optional remote LED annunciator (System Sensor® PN RA100Z) Plug-in mounting provides ease of installation Tamper-proof feature available on mounting bases Listed for use in duct applications Rotary address switches for fast installation UL Listed IDP-Photo (Base not Included) Intelligent Devices MEA 225-02-E Vol. V Specifications* Physical Height: 2.0 (5.0 cm) Diameter: 4.1 (10.4 cm) Shipping Weight: 5.2 oz. (147 g) Electrical Operating Voltage: 1532 VDC Standby Current: 250 µA @ 24 VDC (no communication; LED off) 300 µA @ 24 VDC (one communication every 5 sec with LED enabled) Alarm Current: 6.5 mA @ 24 VDC max (with LED on) Environmental Operating Temperature IDP-Photo: 32º 120ºF (0ºC 49ºC) IDP-Photo-T: 32º 100ºF (0ºC 38ºC) Humidity: 10% 93% non-condensing Other Ratings IDP-Photo-T Thermal: Fixed temperature setpoint 135ºF (57ºC) Velocity: 0 4000 fpm (0 20 m/sec) (suitable for installation in ducts) IDP-Photo Insect Screen Hole Size: 0.016 (0.41 mm) nominal Ordering Information IDP-Photo Photoelectric Smoke Detector IDP-Photo-T Photoelectric Smoke Detector with Thermal (135ºF) IDP-PhotoR Photoelectric smoke detector, remote test capable, for use with DNR (W) duct smoke detector Accessories RA100Z Remote LED Annunciator. XR2B Detector Removal Tool. A removal and replacement tool for IDP plug-in detectors. Includes the T55-127-000. M02-04-01 Detector Test Magnet. M02-09-00 Test Magnet with Telescoping Handle. XP-4 Extension Pole for XR2B. Extends from 5 15 ft. T55-127-000 Detector Removal Head. BCK-200B Black Detector Kit. For IDP-series detectors. * Unless otherwise noted, specifications apply to IDP-Photo and IDP-Photo-T. Wiring IDP-Series Detector Mounting Bases Made in the U.S.A. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: (800) 328-0103, Fax: (203) 484-7118. www.farenhyt.com Addressable Single Action and Dual Action Pull Stations Compatibility The IDP-Pull-SA and IDP-Pull-DA are compatible with the following FACPs: IFP-2000/RPS-2000 Intelligent Fire Panel IFP-1000 Intelligent Fire Panel IFP-100 Intelligent Fire Panel IFP-50 Intelligent Fire Panel P/N 350286 Rev D © 2007 Honeywell International Inc IDP-Pull-SA & IDP-Pull-DA The IDP-Pull-SA is a single action pull station requiring only one motion to activate the station. The IDP-Pull-DA is a dual action pull station requiring two motions to active the station. Both pull stations are designed to work with Silent Knight IFP-series fire alarm control panels (FACPs). Features Installer can open station without causing an alarm condition Dual-color LED is visible through handle of station blinks green to indicate normal operation and remains steady red in an alarm condition Key operated test and reset lock using lock plate actuator Key matches compatible FACP locks Meets the Americans with Disabilities Act Accessibility Guidelines (ADAAG) controls and operating mechanisms guidelines (Section 4.1.3[13]) Meets ADA requirement for 5 lbs maximum pull force to active Shell, door, and handle molded from durable LEXAN® Reliable analog communications for trouble-free operation Braille text on station handle Handle latches in down position and the word Activated appears, clearly indicating the station has been pulled Rotary address switches for fast installation UL Listed, including UL 38, Standard of Manually Actuated Signaling System Installation The IDP-Pull-SA and IDP-Pull-DA can be surface mounted to an SB-I/O surface back box or semi-flush mounted on a standard single-gang with a minimum depth of 2.13(5.40 cm) or double-gang or 4 (10.61 cm) square electrical box. You can also use the optional SSBG-TR (System Sensor® PN BG-TR) trim ring if the station is being semi-flush mounted. IDP-Pull-SA IDP-Pull-DA 7550 Meridian Circle, Suite 100 Maple Grove, Mn 55369-4927 763-493-6455 or 800-328-0103 Fax: 763-493-6475 www.farenhyt.com MEA 67-02-E Vol. IX For IDP-Pull-DA For IDP-Pull-DA Specifications* Physical Height: 5.5 (14 cm) Width: 4 (10.2 cm) Depth: 5.4 oz. (3.7 cm) Housing Material: LEXAN polycarbonate resin Bi-Colored LED: Blinking Green: Normal Steady Red: Alarm Switch: Single pole, single throw (SPST) normally open (N/O) switch which closes upon activation of the pull station Electrical Operating Voltage: 1532 VDC Operating Current (LED flashing): 300 ®A Wire Gauge: Up to 12 AWG (3.1 mm2) Environmental Operating Temperature 32º 120ºF (0ºC 49ºC) Humidity: 10% 93% non-condensing Ordering Information IDP-Pull-SA Single Action Pull Station IDP-Pull-DA Dual Action Pull Station Accessories SSBG-TR Optional trim ring. SB-I/O Surface backbox, indoor/outdoor. * Unless otherwise noted, specifications apply to IDP-Pull-SA andIDP-Pull-DA. For ordering purposes, an SS has been added to the System Sensor part numbers. ExampleSystem Sensor PN for SSB501 is B501. Made in the U.S.A. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Silent Knight 7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927. Phone: (800) 328-0103, Fax: (763) 493-6475. Agency Listings 7125-1653:0504 7135-1653:0503 S5512 S4011 FM approved except for ALERT models 3057383, 3057072 Features • Updated Modern Aesthetics • Small profile devices for Horns and Horn Strobes • Plug-in design with minimal intrusion into the back box • Tamper-resistant construction • Automatic selection of 12- or 24-volt operation at 15 and 30 candela • Field-selectable candela settings on wall units: 15, 30, 75, 95, 110, 135, and 185 • Horn rated at 88+ dBA at 16 volts • Rotary switch for horn tone and two volume selections • Mounting plate for all standard and all compact wall units • Mounting plate shorting spring checks wiring continuity before device installation • Electrically Compatible with legacy SpectrAlert and SpectAlert Advance devices • Compatible with MDL3 sync module • Listed for wall mounting only The System Sensor L-Series offers the most versatile and easy-to-use line of horns, strobes, and horn strobes in the industry with lower current draws and modern aesthetics. With white and red plastic housings, standard and compact devices, and plain, FIRE, and FUEGO-printed devices, System Sensor L-Series can meet virtually any application requirement. The L-Series line of wall-mount horns, strobes, and horn strobes include a variety of features that increase their application versatility while simplifying installation. All devices feature plug-in designs with minimal intrusion into the back box, making installations fast and foolproof while virtually eliminating costly and time-consuming ground faults. To further simplify installation and protect devices from construction damage, the L-Series utilizes a universal mounting plate for all models with an onboard shorting spring, so installers can test wiring continuity before the device is installed. Installers can also easily adapt devices to a suit a wide range of application requirements using field-selectable candela settings, automatic selection of 12- or 24-volt operation, and a rotary switch for horn tones with two volume selections. Indoor Selectable- Output Horns, Strobes, and Horn Strobes for Wall Applications System Sensor L-Series audible visible notification products are rich with features guaranteed to cut installation times and maximize profits with lower current draw and modern aesthetics. L-Series Specifications Architect/Engineer Specifications General L-Series standard horns, strobes, and horn strobes shall mount to a standard 2 x 4 x 1 7/8-inch back box, 4 × 4 × 1½-inch back box, 4-inch octagon back box, or double-gang back box. L-Series compact products shall mount to a single-gang 2 × 4 × 17⁄8-inch back box. A universal mounting plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be used for mounting wall compact models. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, L-Series products, when used with the Sync•Circuit™ Module accessory, shall be powered from a non-coded notification appliance circuit output and shall operate on a nominal 12 or 24 volts. When used with the Sync•Circuit Module, 12-volt-rated notification appliance circuit outputs shall operate between 8.5 and 17.5 volts; 24-volt-rated notification appliance circuit outputs shall operate between 16.5 and 33 volts. Indoor L-Series products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full-wave rectified unfiltered power supply. Strobes and horn strobes shall have field-selectable candela settings including 15, 30, 75, 95, 110, 135, and 185. Strobe The strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and shall be approved for fire protective service. The strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn Strobe Combination The horn strobe shall be a System Sensor L-Series Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. The horn strobe shall be wired as a primary-signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1 Hz over the strobe’s entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two audibility options and an option to switch between a temporal three pattern and a non-temporal (continuous) pattern. These options are set by a multiple position switch. The horn on horn strobe models shall operate on a coded or non-coded power supply. Synchronization Module The module shall be a System Sensor Sync•Circuit model MDL3 listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1 Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn strobe models over a single pair of wires. The module shall mount to a 411⁄16 × 411⁄16 × 21⁄8-inch back box. The module shall also control two Style Y (class B) circuits or one Style Z (class A) circuit. The module shall synchronize multiple zones. Daisy chaining two or more synchronization modules together will synchronize all the zones they control. The module shall not operate on a coded power supply. Physical/Electrical Specifications Standard Operating Temperature 32°F to 120°F (0°C to 49°C) Humidity Range 10 to 93% non-condensing Strobe Flash Rate 1 flash per second Nominal Voltage Regulated 12 DC or regulated 24 DC/FWR1,2 Operating Voltage Range 8 to 17.5 V (12 V nominal) or 16 to 33 V (24 V nominal) Operating Voltage Range MDL3 Sync Module 8.5 to 17.5 V (12 V nominal) or 16.5 to 33 V (24 V nominal) Input Terminal Wire Gauge 12 to 18 AWG Wall-Mount Dimensions (including lens) 5.6˝ L × 4.7˝ W × 1.91˝ D (143 mm L × 119 mm W × 49 mm D) Compact Wall-Mount Dimensions (including lens) 5.26” L x 3.46” W x 1.91” D (133 mm L x 88 mm W x 49 mm D) Horn Dimensions 5.6˝ L × 4.7˝ W × 1.25˝ D (143 mm L × 119 mm W × 32 mm D) Compact Horn Dimensions 5.25” L x 3.45” W x 1.25” D (133mm L x 88mm W x 32mm D) 1. Full Wave Rectified (FWR) voltage is a non-regulated, time-varying power source that is used on some power supply and panel outputs. 2. Strobe products will operate at 12 V nominal only for 15 cd and 30 cd. Horn and Horn Strobe Output (dBA) Switch Position Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR 1 Temporal High 84 89 89 2 Temporal Low 75 83 83 3 Non-Temporal High 85 90 90 4 Non-Temporal Low 76 84 84 5 3.1 KHz Temporal High 83 88 88 6 3.1 KHz Temporal Low 76 82 82 7 3.1 KHz Non-Temporal High 84 89 89 8 3.1 KHz Non-Temporal Low 77 83 83 9* Coded High 85 90 90 10* 3.1 KHz Coded High 84 89 89 * Settings 9 and 10 are not available on the 2-wire horn strobes. UL Max. Strobe Current Draw (mA RMS) Candela 8–17.5 Volts 16–33 Volts DC DC FWR Candela Range 15 88 43 60 30 143 63 83 75 N/A 107 136 95 N/A 121 155 110 N/A 148 179 135 N/A 172 209 185 N/A 222 257 UL Max. Current Draw (mA RMS), 2-Wire Horn Strobe, Candela Range (15–115 cd) DC Input 8-17.5 Volts 16-33 Volts 15cd 30cd 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 98 158 54 74 121 142 162 196 245 Temporal Low 93 154 44 65 111 133 157 184 235 Non-Temporal High 106 166 73 94 139 160 182 211 262 Non-Temportal Low 93 156 51 71 119 139 162 190 239 3.1K Temporal High 93 156 53 73 119 140 164 190 242 3.1K Temporal Low 91 154 45 66 112 133 160 185 235 3.1K Non-Temporal High 99 162 69 90 135 157 175 208 261 3.1K Non-Temporal Low 93 156 52 72 119 138 162 192 242 FWR Input 16-33 Volts 15cd 30cd 75cd 95cd 110cd 135cd 185cd Temporal High 83 107 156 177 198 234 287 Temporal Low 68 91 145 165 185 223 271 Non-Temporal High 111 135 185 207 230 264 316 Non-Temportal Low 79 104 157 175 197 235 283 3.1K Temporal High 81 105 155 177 196 234 284 3.1K Temporal Low 68 90 145 166 186 222 276 3.1K Non-Temporal High 104 131 177 204 230 264 326 3.1K Non-Temporal Low 77 102 156 177 199 234 291 UL Max. Horn Current Draw (mA RMS) Sound Pattern dB 8–17.5 Volts 16–33 Volts DC DC FWR Temporal High 39 44 54 Temporal Low 28 32 54 Non-Temporal High 43 47 54 Non-Temporal Low 29 32 54 3.1 KHz Temporal High 39 41 54 3.1 KHz Temporal Low 29 32 54 3.1 KHz Non-Temporal High 42 43 54 3.1 KHz Non-Temporal Low 28 29 54 Coded High 43 47 54 3.1 KHz Coded High 42 43 54 UL Current Draw Data Horn Tones and Sound Output Data 3825 Ohio Avenue • St. Charles, IL 60174 Phone: 800-SENSOR2 • Fax: 630-377-6495 www.systemsensor.com ©2017 System Sensor. Product specifications subject to change without notice. Visit systemsensor.com for current product information, including the latest version of this data sheet. AVDS86503 • 03/17 L-Series Dimensions Model Description Wall Horn Strobes P2RL 2-Wire, Horn Strobe, Red P2WL 2-Wire, Horn Strobe, White P2GRL 2-Wire, Compact Horn Strobe, Red P2GWL 2-Wire, Compact Horn Strobe, White P2RL-P 2-Wire, Horn Strobe, Red, Plain P2WL-P 2-Wire, Horn Strobe, White, Plain P2RL-SP 2-Wire, Horn Strobe, Red, FUEGO P2WL-SP 2-Wire, Horn Strobe, White, FUEGO Wall Strobes SRL Strobe, Red SWL Strobe, White SGRL Compact Strobe, Red SGWL Compact Strobe, White SRL-P Strobe, Red, Plain SWL-P Strobe, White, Plain SRL-SP Strobe, Red, FUEGO SWL-CLR-ALERT Strobe, White, ALERT L-Series Ordering Information Notes: All -P models have a plain housing (no “FIRE” marking on cover) All -SP models have “FUEGO” marking on cover All -ALERT models have “ALERT” marking on cover Compact Strobe / Horn Strobe Strobe / Horn Strobe Compact Horn Horn Model Description Horns HRL Horn, Red HWL Horn, White HGRL Compact Horn, Red HGWL Compact Horn, White Accessories TR-2 Universal Wall Trim Ring Red TR-2W Universal Wall Trim Ring White SBBRL Wall Surface Mount Back Box, Red SBBWL Wall Surface Mount Back Box, White SBBGRL Compact Wall Surface Mount Back Box, Red SBBGWL Compact Wall Surface Mount Back Box, White