HomeMy WebLinkAboutA18-0047_approved documents_1533319259.pdfDN-60054:A • 04/18/18 — Page 1 of 4 Relay Base B224RB(A) Flanged Mounting Base B210LP(A)60054b5.jpg60054rb.jpg60054sr.jpg Standard Flanged Low-Profile Base B300-6 Flangeless Mounting Base B501(A)60054b5.jpgSounder Base B200S(A), B200SR(A), B200SCOA Low-Frequency Sounder Base B200S-LF, B200SR-LF Intelligent Bases Standard, Relay, Isolator, Sounder, and Low-Frequency Sounder Bases General Intelligent FlashScan® and CLIP detector mounting bases are avail- able to install NOTIFIER detectors in any application. Bases are available for the new, modern looking aesthetically pleasing 900 series addressable detectors, as well as previous series detectors. Both flanged and flangeless bases are available. To meet code and specific application requirements Relay, Isolator and Sounder Bases versions are available. Relay bases provide one form-C contact for auxiliary functions such as door closure and elevator recall. Isolator bases allow loops to continue to operate under fault conditions and automatically restore when the fault is removed. Sounder bases are available in temporal and non-tempo- ral pattern versions depending on whether the signal is to be used for evacuation purposes. Low frequency sounder bases are UL listed for low frequency operation and comply with NFPA 72 require- ments for sleeping spaces. Specifications NOTE: Specifications applies to all model variants “A”, “-BL”, “-LF”, “-IV”. See Product Line Information for detailed model description. Diameter • B501: 4" (10.16 cm) diameter. • B300-6: 6.1" (15.49 cm) diameter. • B224RI, B224RB, B210LP: 6.2" (15.748 cm) diameter. • B200S, B200SR, B200SCOA: 6.875" (17.46 cm) diameter. Wire gauge: • B224BI, B224RB: 14 to 24 AWG. • B300-6, B210LP, B501, B200S, B200SR, B200SCOA: 12 to 24 AWG Temperature range: • B224BI, B224RB, B200S, B200SR, B200SCOA: 32°F to 120°F (0°C to 49°C). • B300-6, B210LP, B501: -4°F to 150°F (-20°C to 66°C). Humidity range: 10% to 93% RH, non-condensing. System temperature and humidity ranges: This system meets NFPA requirements for operation at 0°C to 49°C (32°F to 120°F); and at a relative humidity (noncondensing) of 85% at 30°C (86°F) per NFPA, and 93% ± 2% at 32°C ± 2°C (89.6°F ± 1.1°F) per ULC. However, the useful life of the system’s standby batteries and the electronic components may be adversely affected by extreme tem- perature ranges and humidity. Therefore, it is recommended that this system and all peripherals be installed in an environment with a nominal room temperature of 15°C to 27°C (60°F to 80°F). Electrical Ratings FOR B200 SERIES BASES: External supply voltage: 16 to 33 VDC (VFWR) Standby current: 500 μA maximum. Alarm current: • B200S(A)(-IV) – 35 mA maximum at high-volume setting. – 15 mA maximum at low-volume setting. • B200S-LF(-IV), High-volume setting: – 70 mA maximum @ 33.0 VDC. – 90 mA maximum @ 24.0 VDC. – 140 mA maximum @16.0 VDC. • B200S-LF(-IV), Low-volume setting: – 15 mA maximum @ 33.0 VDC. – 20 mA maximum @ 24.0 VDC. – 25 mA maximum @ 16.0 VDC. • B200SR(A)(-IV) – 35 mA maximum. • B200SR-LF(-IV) – 65 mA maximum @ 33.0 VDC. – 90 mA maximum @ 24.0 VDC. – 125 mA maximum @16.0 VDC. • B200SCOA(-IV) – 40mA Max. (DC) – 70mA Max. (FWR) SLC operating voltage: 15 to 32 VDC. SLC standby current: See applicable sensor specification. Sound output: • B200S(A)(-LF)(-IV), high-volume*: Greater than 85 dBA mini- mum. • B200S(A)(-LF)(-IV), low-volume*: Greater than 75 dBA minimum. • B200SR(A)(-LF)(-IV)*: Greater than 85 dBA minimum. • B200SCOA(-IV), high-volume**: Greater than 87 dBA minimum. • B200SCOA(-IV), low-volume**: Greater than 85 dBA minimum Vail Fire & Emergency Services 08/03/18 Page 2 of 4 — DN-60054:A • 04/18/18 *Measured in a UL reverberant room at 10 feet, 24 Volts (continuous tone) **Measured in a ULC anechoic room at 10 feet, 24 Volts continuous tone) FOR B224BI, B224RB (A) (-IV): Operating voltage: 15 to 32 VDC (powered by SLC). Standby ratings: <500 μA maximum @ 24 VDC. Set time (B224RB(A)(-IV) only): short delay 55 to 90 msec; long delay 6 to 9 seconds. Reset time (B224RB(A)(-IV) only): 20 msec maximum. Relay characteristics (B224RB(A)(-IV) only): two-coil latching relay; one Form-C contact; ratings (UL/CSA): 0.9 A @ 125 VAC, 0.9 A @ 110 VDC, and 3.0 A @ 30 VDC. Product Line Information INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: “-IV” suffix indicates Ivory color model. NOTE: “-BL” suffix indicates Black color model. B210LP: Flanged mounted base. B210LPA: Same as B210LP ULC listed. B210LPBP: Bulk pack of B210LP contains 10. B300-6: White, 6” base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109) B300A-6: Same as B300-6, ULC listed. B300-6-BP: Bulk pack of B300-6, package contains 10 B300-6-IV: Ivory,6” base, standard flanged low-profile mounting base. (CSFM: 7300-1653:0109) B300A-6-IV: Ivory, 6” standard flanged low-profile mounting base, ULC listed. B501-WHITE: White, 4” standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109) B501-WHITE-BP: Bulk pack of B501-WHITE contains 10. B501-BL: Black, 4” standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109) B501-IV: Ivory color, 4” standard European flangeless mounting base. UL/ULC listed. (CSFM: 7300-1653:0109) B224RB-WH: White, relay base. (CSFM: 7300-1653:0216) B224RB-IV: Ivory, relay base. (CSFM: 7300-1653:0216) B224RBA-WH: White, relay base, ULC listing. B224RBA-IV: Ivory, relay base, ULC listing. B224BI-WH: White, isolator detector base. (CSFM: 7300- 1653:0216) B224BI-IV: Ivory isolator detector base. (CSFM: 7300-1653:0216) B224BIA-WH: White, isolator detector base, ULC listing. B224BIA-IV: Ivory isolator detector base, ULC listing. B200S-WH: White, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200S-IV: Ivory, Intelligent addressable sounder base capable of producing sound output in high or low volume with ANSI Temporal 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. Uses FlashScan protocol. (CSFM: 7300-1653:0213) B200SA-WH: Same as B200S-WH, ULC listing. B200SA-IV: Same as B200S-IV, ULC listing. B200SCOA-WH: White, Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications. B200SCOA-IV: Ivory Intelligent, programmable sounder base in English/French (required in Canada for ULC applications with SO Series detector applications, ULC listing. B200S-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200S-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. (CSFM: 7300-1653:0238) B200SR-WH: White, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SR-IV: Ivory, Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Intended for retrofit applications. (CSFM: 7300-1653:0213) B200SRA-WH: Same as B200SR-WH with, ULC listing. B200SRA-IV: Same as B200SR-IV in Ivory color, ULC listing. B200SR-LF-WH: White, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) B200SR-LF-IV: Ivory, Low Frequency Intelligent, programmable sounder base. Produces a fundamental frequency of 520 Hz +/- 10% with a square wave or its equivalent; designed to meet the NFPA 72 sleeping space requirement. Intended for retrofit applica- tions. (CSFM: 7300-1653:0238) MOUNTING KITS AND ACCESSORIES TR300: White, replacement flange for B210LP(A) base. TR300-IV: Ivory, replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Mounts to a U.S. single-gang electrical box. For use with B501(A) and B300(A)- 6. M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applications. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524m) sec- tions. T55-127-010: Detector removal tool without pole. CK300: White, detector color kit. Pack of 10. CK300-IR: White, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. CK300-IV: Ivory, detector color kit. Pack of 10. CK300-IR-IV: Ivory, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. CK300-BL: Black, detector color kit. Pack of 10. CK300-IR-BL: Black, detector color kit for use with FPTI and FCO Series detectors. Pack of 10. Vail Fire & Emergency Services 08/03/18 DN-60054:A • 04/18/18 — Page 3 of 4 Agency Listings and Approvals The listings and approvals below apply to intelligent bases as noted. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL Listed: S911, S1115 • ULC Listed: S911, S1115. •FM Approved. • MEA: 22-95-E, 205-94-E Vol. 2; 257-06-E • CSFM: 7270-0028-0502, 7272-0028:0503, 7300-1653:0126, 7135-1653:0213, 7300-1653:0109 Junction Box Selection Guide Base Models Single Gang 3.5" Oct. 4.0" Oct. 4.0" Sq. 4.0" Sq. with 3.0" mud ring 50 mm 60 mm 70 mm 75 mm B200S, B200SR, B200SCOA Yes Yes Yes Yes Yes No No No No B501 No Yes No No Yes Yes Yes Yes No B210LP Yes Yes Yes Yes Yes No No No No B224RB No Yes Yes Yes No No Yes Yes Yes B224BI No Yes Yes Yes No No No Yes Yes NOTE: Box depth contingent on base and wire size. Refer to National Electric Code or applicable local codes for appropriate recommendations. NOTE: Applies to all model variants “A”, “-BL”, “-LF”, “-IV”. See Product Line Information for detailed model description. Vail Fire & Emergency Services 08/03/18 FlashScan®, NOTIFIER® and System Sensor® are regis- tered trademarks of Honeywell International Inc. ©2018 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. Country of Origin: USA NOTIFIER 12 Clintonville Road Northford, CT 06472 203.484.7161 www.notifier.com Vail Fire & Emergency Services 08/03/18 DN-60689:C • 8/7/17 — Page 1 of 2 FCO-851(A) IntelliQuad™ PLUS Advanced Multi-Criteria Fire/CO Detector Intelligent/Addressable Devices DN-60689:C General World-class fire and carbon monoxide (CO) detection com- bined in a single addressable device provides a practical solu- tion for today’s market. The IntelliQuad PLUS FCO-851(A) Advanced Multi-Criteria Fire/CO Detector is a plug-in, addressable device that pro- vides both fire and carbon monoxide (CO) detection. For fire, the detector combines four separate sensing elements in one unit (smoke, CO, light/flame, and heat) to sense multiple com- ponents of a fire. This approach enables enhanced sensitivity to real fire with heightened immunity to nuisance particulate. For CO, the detector’s electrochemical sensing cell creates a separate signal for life safety CO detection. CO is a colorless, odorless, and deadly gas that is virtually impossible to detect with the human senses. It is released whenever carbon-based fuels (from fossil fuels to firewood) burn without enough oxygen to form CO2. Because the poten- tial exists for dangerous levels of CO to accumulate in almost any building, legislation mandating the use of CO detection in commercial spaces continues to increase across the U.S. and Canada. The FCO-851(A) is listed to the UL 268 standard for smoke detectors and the UL 2075 standard for system-con- nected life safety carbon monoxide monitoring. The FCO-851(A) should be used in conjunction with the B200S(COA) intelligent sounder base, which can generate either a Temp 3 pattern for fire or a Temp 4 pattern for CO alarm indication. The B200S(COA) recognizes the System Sensor synchroniza- tion protocol. This enables it to be used as a component of the general evacuation signal — along with other System Sensor horns, horn strobes, and chimes — when connected to a power supply or Fire Alarm Control Panel (FACP) output capa- ble of generating the System Sensor synchronization pulses. With each sounder base carrying a unique address, the FACP can then command an indvidual sounder — or a group of sounders — to activate. The command set from the panel can be tailored to the specific event, allowing selection of volume, tone, and group. NOTE: The FCO-851(A) is compatible with the NFS-320(C), NFS- 320SYS, NFS2-640, and NFS2-3030 operating with firmware ver- sion 17.0 (or higher) in FlashScan® mode; CLIP mode not sup- ported. Features • Unique ability to detect all four major elements of a fire. • Separate CO detection signal. • Highest nuisance alarm immunity. • Automatic drift compensation of smoke sensor and CO cell. • Uses only one address on the SLC. • RealTest® CO testing capability. • Separates audible signal for fire or CO alarm when used with the B200S base (B200SCOA in Canada). • CO cell end-of-life warning and fault. • FlashScan operation. Sensitivity Settings and Suggested Applications • Level 1: 1% / ft of smoke. Suggested for very clean envi- ronments such as laboratories. • Level 2: 2% / ft of smoke. Suggested for clean environ- ments such as offices. • Level 3: 3% / ft of smoke. Suggested for moderately clean environments such as hotel rooms, dorm rooms. • Level 4: 3% / ft of smoke with different algorithm process- ing and weighting of sensor elements. Suggested for hotel rooms near a shower, boiler rooms. • Level 5: 4% / ft of smoke. Suggested for equipment rooms, kitchens, paint shops. • Level 6: Thermal alarm at 135°F (57°C). Once the CO cell has reached end-of-life, the CO sensor no longer provides life safety protection; however, when the fire detector enters Photo, Thermal, Infrared (PTIR) mode, the fol- lowing sensitivities apply: • Level 1: 1% / ft of smoke. Suggested for very clean envi- ronments such as laboratories. • Level 2: 2% / ft of smoke. Suggested for clean environ- ments such as offices. • Level 3: 3% / ft of smoke. Suggested for moderately clean environments such as hotel rooms, dorm rooms. • Level 6: Thermal alarm at 135°F (57°C). Specifications PHYSICAL SPECIFICATIONS Size: 3.46" (8.79 cm) high x 6.875" (17.46 cm) diameter installed in B200S(COA) base. Shipping weight: 4.6 oz. (130.41 g). Color: Ivory.60689cov.JPGFCO-851(A) in B200S(COA) Sounder Base Vail Fire & Emergency Services 08/03/18 Page 2 of 2 — DN-60689:C • 8/7/17 IntelliQuad™ is a trademark and NOTIFIER®, RealTest® and FlashScan® are registered trademarks of Honeywell International Inc. ©2017 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Country of Origin: USA Operating humidity range: 15% – 90% relative humidity (noncondensings). Operating temperature: 0°C to 38°C (32°F to 100°F). Air velocity: 0 – 4000 ft./min. (0 to 20 m/sec.). ELECTRICAL SPECIFICATIONS Operating Voltage range: 15 – 32 volts VDC. Standby current (max. avg.): 300 µA at 24 VDC (one com- munication every 5 seconds with LED blink enabled). Maximum Alarm Current (LED on): 7.2 mA at 24 VDC. CO ALARM ACTIVATION LEVELS Alarm activation levels as defined by UL Standard 2034: Ordering Information NOTE: “A suffix indicates ULC listed model. FCO-851: IntelliQuad PLUS Advanced Multi-Criteria Fire/CO Detector. FCO-851A: IntelliQuad PLUS Advanced Multi-Criteria Fire/CO Detector, ULC listed. BX-501 Intelligent Detectors/Sensors Base. B501 Intelligent base. B501BH Sounder base. B501BH-2 Sounder base, steady tone. B501BHT-2 Sounder base, temporal tone. B200S/A Intelligent programmable, addressable sounder base. B200SR/A Sounder base. B200S-LF Addressable Low Frequency sounder base. B200SR-LF Low Frequency sounder base. B210LP/A Intelligent detector base. B200SCOA: Intelligent programmable sounder base, ULC listed. Includes CO detector markings in English and French. M02-04-00: Detector Test Magnet. M02-09-00: Telescoping Test Magnet. Agency Listings and Approvals The listings and approvals below apply to the primary product. In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL: S1115 (FCO-851). • ULC: SS527-11 (FCO-851A). • CSFM: 7275-0028:0264. Concentration of CO Maximum Alarm Time Response 70 (+/- 5) PPM 240 min (not less than 60 min) 150 (+/- 5) PPM 50 min (not less than 10 min) 400 (+/- 10) PPM 15 min (not less than 4 min) Vail Fire & Emergency Services 08/03/18 DN-6937:D • 12/07/2011 — Page 1 of 2 FAPT-851(A) Acclimate® Plus™ Multi-Sensor Low-Profile Intelligent Detector Intelligent/Addressable Devices DN-6937:D General The Notifier FAPT-851(A) Acclimate® Plus™ detector is an intelligent, addressable, multi-sensing, low-profile detector designed for use with Notifier Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). The Acclimate Plus detector uses a combination of photoelec- tric and thermal sensing technologies to increase immunity to false alarms. Unlike traditional intelligent detectors, the Accli- mate Plus detector has a microprocessor in the detector head that processes alarm data. As a result, the Acclimate Plus detector adjusts its sensitivity automatically, without operator intervention or control panel programming. Areas where the Acclimate Plus detector is especially useful include office complexes, schools, college campuses, manu- facturing and industrial facilities, and anywhere else the use of a particular area may change. The Acclimate Plus detector automatically adjusts its sensitivity to the environment. FlashScan® (U.S. Patent 5,539,389) is a communication pro- tocol developed to greatly enhance the speed of communica- tion between analog intelligent devices and compatible systems. Intelligent devices communicate in a grouped fash- ion. If one of the devices within the group has new information, the panel’s CPU stops the group poll and concentrates on sin- gle points. The net effect is response speed greater than five times that of earlier designs. Features • Automatically adjusts sensitivity levels without operator intervention or programming. Sensitivity increases with heat. • Microprocessor-based, combination photo and thermal technology. • Compatible with all Notifier Onyx and CLIP series Fire Alarm Control Panels (FACPs). • Addressable-analog communication. • Sleek, low-profile design. • Two-wire SLC connection. • Rotary, decimal addressing (1-99 on CLIP systems, 1-159 on FlashScan systems). • Addresses can be viewed and changed without electronic programmers. • Dual bi-color LED design provides 360° viewing angle. • LEDs lock red when in alarm. In FlashScan, LEDs flash green in standby for normal condition. • Built-in tamper-resistant feature. • Constructed of off-white fire-resistant plastic, designed to commercial standards, and offers an attractive appearance. • SEMS screws for wiring of the separate base. • Several base options, including relay, isolator, and sounder. • Built-in functional test switch activated by external magnet. • Listed to UL 268. • Capable of heat-only alarm mode, enabled by a special command from the panel. Smoke alarms are ignored. • Low-temperature signal at 45°F +/– 10°F (7.22°C +/– 5.54°C). Specifications Sensitivity: auto-adjusting levels: 1 to 2%/ft. and 2 to 4%/ft. with classic CLIP systems; 1 to 2, 2 to 3, and 3 to 4%/ft. with systems; fixed-sensitivity levels: 1, 2, and 4%/ft. with classic CLIP systems; 0.5, 1, 2, 3, and 4%/ft. with FlashScan systems. Size: 2.0" (5.3 cm) high; base determines diameter. – B210LP(A): 6.1" (15.5 cm) diameter. – B501(A): 4.1" (10.4 cm) diameter. – B200S(A): 6.875" (17.46 cm) diameter. – B200SR(A): 6.875" (17.46 cm) diameter. – B224RB(A): 6.2" (15.748 cm) diameter. Shipping weight: 5.2 oz. (147 g). Operating temperature: 0°C to 38°C (32°F to 100°F). UL-Listed velocity range: 0 – 4000 ft./min. (1219.2 m/min.), suitable for installation in ducts. Relative humidity: 10% – 93% noncondensing. Thermal sensing rating: fixed-temperature setpoint 135°F (57°C). ELECTRICAL SPECIFICATIONS Voltage range: 15 – 32 volts DC peak. Standby current (max. avg.): 300 A. Loop resistance: 50 ohms maximum; varies according to control panel used. Refer to panel installation manuals. LED current (max.): 6.5 mA @ 24 VDC (“ON”). Installation The FAPT-851(A) plug-in detector uses a separate base to simplify installation, service, and maintenance. A special tool allows maintenance personnel to plug-in and remove detec- tors without using a ladder. Suitable mounting base boxes include: FAPT-851(A) in B210LP(A) Base FAPT-851 with B210.pngVail Fire & Emergency Services 08/03/18 Page 2 of 2 — DN-6937:D • 12/07/2011 Notifier®, ONYX®, FlashScan®, and Acclimate® are registered trademarks and Acclimate Plus™ is a trademark of Honeywell International Inc. ©2011 by Honeywell International Inc. All rights reserved. Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. For more information, contact Notifier. Phone: (203) 484-7161, FAX: (203) 484-7118. www.notifier.com Made in the U.S. A. • 4.0" (10.16 cm) square box. • 3.5" (8.89 cm) or 4.0" (10.16 cm) octagonal box. • Single-gang box (except relay or isolator base). NOTE: The FAPT-851(A) detector has the unique ability to adjust sensitivity according to the environment, based on heat and smoke levels. Avoid installing these detectors in locations that are susceptible to rapid and high temperature changes. An example of an incorrect application would be near or in line with the output of a self-contained heater. Agency Listings and Approvals These listings and approvals apply to the modules specified in this. In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess. Consult factory for latest listing status. • UL Listed: S1115. • ULC Listed: S1115. • MEA Listed: 225-02-E. • FM Approved. • CSFM: 7272-0028:0206. • U.S. Coast Guard: 161.002/42/1 (NFS-640); 161.002/50/0 (NFS2-640/NFS-320/NFS-320C, excluding B210LP(A)). • Lloyd’s Register: 11/600013 (NFS2-640, NFS-320/NFS- 320C, excluding B210LP(A)). • Maryland State Fire Marshal: Permit # 2122. Ordering Information NOTE: “A” suffix indicates ULC Listed model. FAPT-851: Low-profile intelligent multi-sensor detector. FAPT-851A: Same as FAPT-851 but with ULC Listing. INTELLIGENT BASES NOTE: “A” suffix indicates ULC Listed model. NOTE: For details about intelligent bases and their mounting, see DN-60054. B210LP(A): Plug-in detector base; standard U.S. flanged low- profile mounting base. B210LPBP: Bulk pack of B210LP; package contains 10. B501(A): Flangeless mounting base. B501BP: Bulk pack of B501; package contains 10. B200S(A): Intelligent, programmable sounder base capable of producing sound output in high or low volume with ANSI Tem- poral 3, ANSI Temporal 4, continuous tone, marching tone, and custom tone. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Replaces B501BH series bases in retrofit applications. B224RB(A): Relay base Screw terminals: up to 14 AWG (2.0 mm²). Relay type Form-C. Rating: 2.0 A @ 30 VDC resistive; 0.3 A @ 110 VDC inductive; 1.0 A @ 30 VDC inductive. B224BI(A): Isolator base. Maximum: 25 devices between iso- lator bases. ACCESSORIES F110: Retrofit flange to convert B210LP to match the B710LP profile, or to convert older high-profile bases to low-profile. F110BP: Bulk pack of F110; package contains 15. F210: Replacement flange for B210LP(A) base. RA100Z(A): Remote LED annunciator. 3 – 32 VDC. Fits U.S. single-gang electrical box. Supported by B210LP(A) and B501(A) bases only. SMB600: Surface mounting kit for use with B210LP(A). M02-04-00: Test magnet. M02-09-00: Test magnet with telescoping handle. XR2B: Detector removal tool. Allows installation and/or removal of FlashScan® Series detector heads from base in high ceiling installations. T55-127-010: Detector removal tool without pole. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 m) sections. Vail Fire & Emergency Services 08/03/18 !August 1, 2018 Vail Fire 42 West Meadow Drive Vail, CO 81657 Attn: Mike Vaughan, Fire Marshal Pjct: Antlers Unit 403 Re: Scope of Work for Fire Alarm System Addition Dear Mike, The scope of work will be to bring the remodeled area up to NFPA standards adopted by Vail Fire. Work performed will be to one new FAPT- multi-criteria smoke detector to the each bedroom of the unit along with a B200S-LF low frequency sounder base to match the existing system. There are a total of two bedrooms In addition one multi-criteria combination smoke/CO FCO-851’s will in the living room by the fire place along with the B200SLF sounder bases. These devices will be added to the current main fire alarm control system, a Notifier NFS2-3030 in and will provide continuity between Unit 702 and the existing building. Once work has been completed and tested, CSI will contact Vail Fire Department and schedule a final fire alarm test of the new area. If there are any questions or concerns about the above information, please feel free to contact me at any time. Sincerely, Commercial Specialists of Western Colorado, LLC Tim Ward Tim Ward Vice President NICET Level IV 115941 601 Mulberry Street * Grand Junction Colorado 81501 210 Marmot Lane Unit 5B * Eagle, Colorado 81631 Voice (970) 328.1951 Fax (970) 328.1956 www.cswcfire.com Commercial Specialists, Inc. * Fire Alarm * BI - Directonal Amplifers * Test & Inspectons * * Security * Intercom * Area of Rescue * Access Control * Approved for install/changes. Vail Fire & Emergency Services 08/03/18