Loading...
HomeMy WebLinkAboutB08-0249 PLANSIm architects •r *rwrr+�wwwrrrwrrr•wwwwwrww• ML ECTR I CAL. 5Y MEKL 5 X CEILING MOUNTED INGANDE50ANT +PC CLG MTD fNCANDE5GANT W/ PULL CHAIN &ENERALM REEOU I REMIENTS g WALL MOUNTED INGANDE50ANT ® RECE55ED INGANDE50ANT -IC RATED A. GENERAL - ® RECESSED DIRECTIONAL INGANDESCANT 1. NOTIFY ARCHITECT IMMEDIATELY OF ANY 2, PRIOR TO THE START OF ANY WORK, THE EXHAUST FAN -VENT TO EXTERIOR CONFLICTS BETWEEN ANY CONTRACT DOCUMENTS CONTRACTOR AND SUBCONTRACTORS PRIOR TO THE START OF WORK. RE5PON51BLE FOR THE WORK SHOWN IN THESE FLOOD LIGHT W/ MOTION 5EN5OR DOCUMENTS SHALL INSPECT AND APPROVE ALL 2. IN THE EVENT OF ANY CONFLICTS BETWEEN THE PREPATORY WORK THAT HAS BEEN COMPLETED TO (j)5D SMOKE DETECTOR -AC- INTER - CONNECTED DOCUMENTS, THE ITEM OF M05T OR GREATEST RECEIVE His WORK. HE 15 TO ENSURE THAT HIS W BATTERY BACK -UP EXTENT OF WORK AS DETERMINED BY THE WORK AND ADJACENT WORK WILL FINISH TO ARCHITECT SHALL APPLY AND BE PERFORMED BY PROPER CONTOURS, PLANES AND LEVELS. }---t UNDER- CABINET COUNTER -TOP LIGHTING THE CONTRACTOR AT NO ADDITIONAL COST. PROMPTLY NOTIFY GENERAL CONTRACTOR OF ANY DEFECTS IN THE PREP WORK THAT WILL,. 5, ALL TRADES SHALL PERFORM THEIR WORK ADVERSELY AFFECT OR PREVENT THE WITHIN THE RECOGNIZED STANDARDS OF THE SATISFACTORY COMPLETION OF H15 WORK. , PADDLE FAN APPLICABLE INDUSTRY. FAILURE TO NOTIFY GENERAL CONTRACTOR SHALL I INDICATE ACCEPTANCE OF THE PREP WORK AND \ ,' 4. ANY DEVIATION OR CHANGE IN THE WORK FROM ANY 5UB5EOUENT CLAIMS OF DEFECT5 5HALL NOT THE CONTRACT DOCUMENTS WITHOUT PERMISSION BE RECOGNIZED. OF THE ARCHITECT PLACES ALL RESPONSIBILITY FOR THE DEVIATION OR CHANGE ON THE 3. NO WORK SHALL BE PERFORMED UNTIL ALL 2'x4' FLUORESCENT CONTRACTOR. PREP WORK HAS BEEN COMPLETED, CURED, DRIED, ETC AND READY TO RECEIVE THE WORK. GENERAL 5, THESE DOCUMENTS WERE PREPARED WITHOUT CONTRACTOR 15 RESPONSIBLE FOR THE TIMELY REGARD FOR THE D11/1510N OF WORK AMONG COORDINATION AND INSTALLATION OF ALL TRADES, GENERAL CONTRACTOR 15 TO MATERIALS. 1'x4' FLUORESCENT COORDINATE AND PROVIDE ALL WORK SHOWN ON THESE DOCUMENTS WITH ALL TRADES RE6ARDLE55 L OF WHICH DRAWING WORK 15 SHOWN ON. V 6. TH15 PROJECT 15 GOVERNED BY THE 2005 F L_ U M 5 I 1 ` 6 � M E C. H A N I C A L_ INTERNATIONAL BUILDING GODS AS ADOPTED BY ® ® W THE TOWN of VAIL, COLORADO, THE DRAWIN65 DO 1. INSTALLATION OF ALL PLUMBING 5. DOMESTIC WATER SYSTEM: NOT ALLOW WORK THAT DOES NOT COMPLY WITH AND MECHANICAL WORK SHALL PROVIDE COPPER PIPING THROUGHOUT. THESE CODES. GENERAL CONTRACTOR AND H15 COMPLY WITH ALL LOCAL CODES, PROVIDE ARMAFLEX INSULATION ON 5UB- CONTRACTORS ARE RESPONSIBLE FOR RULES AND RE6ULATION5 AND THE HOT WATER PIPING. COMPLYING WITH ALL APPLICABLE 001*2E5, 2003 INTERNATION MECHANICAL AND 1 ORDIANCE5, RULES REGULATIONS, ETC,, BY ALL PLUMBING CODES AS ADOPTED BY b, PROVIDE 50HEDULE 40 PVC AUTHORITIES HAYING JURISDICTION. GENERAL THE TOWN OF VAIL. SANITARY 5EWER PIPING WITH CONTRACTOR 15 RESPONSIBLE FOR OBTAINING AND CLEANOUT5 AS REQUIRED. FIELD PAYING FOR ALL REQUIRED PERMITS. 2. FIELD VERIFY ALL EXI5TIN6 VERIFY AND CONNECT TO EXI5ITN6 PLUMBING FROM ABOVE AND SANITARY SEWER SYSTEM 7. ALTHOUGH TrD architects HAS PERFORMEND ITS RELOCATE AS READ- NOTIFY OWNER SERVICE WITH DUE DILIGENCE AND CARE, IT DOES AT LEAST 72 HOURS IN ADVANCE OF '7. NEW BATHROOM EXHAUST FANS TO NOT GUARANTEE PERFECTION. EVERY EFFORT IS ANY DISRUPTION TO 5ERVICES ABOVE HAVE SMOKE DAMPERS AS REOD BY MADE TO PROVIDE A COMPLETE AND CLEAR SET BLDG CODE OF CONSTRUCTION DOCUMENTS, HOWEVER, 3. RE -USE ALL EXI5TNG STACKS, DISCREPANCIES OR OMISSIONS MAY OCCUR, VENTS, ETG AS FAR AS RELEASE OF THESE DOCUMENTS ANTICIPATES PRACTICAL- PROVIDE NEW AS REOD COOPERATION BETWEEN THE CONTRACTOR, OWNER AND ARCHITECT TO PROVIDE THE BEST POSSIBLE 4. PROVIDE SUBMITTALS FOR ALL PROJECT. THESE DRANIN65 HAVE BEEN PREPARED PLUMBING WORK PRIOR TO THE START FOR THE USE OF A QUALIFIED CONTRACTOR OF ANY WORK., EXPERIENCED IN THE CONSTRUCTION TEGHNIOUE5 AND SYSTEMS SHOWN, 5. GENERAL CONTRACTOR AND HI E L. E C T I C A L_ SUB - CONTACTORS ARE TO FIELD VERIFY ALL DIMENSIONS, EXI5TIN6 CONDITIONS, UTILITY LOCATIONS, ETC,., PRIOR TO BEGINNING ANY WORK 1. INSTALLATION OF ALL ELECTRICAL 4. ELECTRICAL CONTRACTOR TO OR ORDERING ANY MATERIALS, NOTIFY ARCHITECT WORK SHALL COMPLY WITH ALL COORDINATE NEW AND EXI5TIN6 OF DISCREPANCIES OR INCONSISTENCIES IN THESE LOCAL CODES, RULES AND SWITCHING WITH OWNER. DRAWING IMMEDIATELY. RE6ULATION5 AND THE NATIONAL B. SCOPE of WORK ELECTRICAL CODE, CURRENT EDITION. 5. OUTLETS, 5WITCHE5 AND PLATE INSTALL TELEPHONE AND CABLE TV COVERS THROUGHOUT THE PROJECT 1. THE INTENT OF THE CONTRACT DOCUMENTS 15 PER RE5PECTIVE COMPANIES' TO BE VEGORA' -COLOR AS THAT EACH CONTRACTOR SHALL PERFORM ALL REG2UIREMENT5; SELECTED. PROVIDE IC RATED ACTIONS NECESSARY AND REQUIRED TO PROVIDE RECE55ED CANS IN ALL ALL LABOR, MATERIALS, SUPPLIES, EQUIPMENT, 2. THE ELECTRICAL CONTRACTOR CEILIING5 -JUN0 OR EQUIVALENT. ALL TRANSPORTATION, FACILITIES AND SHALL PROVIDE PANEL SCHEDULES, FIXTURES TO BE U.L. LISTED, APPURTENANCES WHICH ARE INDICATED OR EQUIPMENT INFORMATION, AND REASONABLY IMPLIED BY EACH DRAWING AND COMPLETE SUBMITTALS, INCLUDING 6. SMOKE DETECTORS SHALL BE SPECIFICATION SECTION, ALL OF WHICH 15 LIGHTING, WITHIN 30 DAYS OF THE INSTALLED AS 5HOWN AND /OR IN COLLECTIVELY NECE55ARY AND REQUIRED FOR START OF WORK. ACCORDANCE WITH LOCAL FIRE THE EXECUTION OF THE WORK AS 5HOWN ON THE DEPARTMENT. DETECTORS SHALL BE CONTRACT DOCUMENTS. 3. THE ELECTRICAL CONTRACTOR WIRED INTO THE BUILDING ELECTRICAL SHALL PAY THE ELECTRICAL PERMIT SYSTEM, INTER - CONNECTED AND WITH 2. WRITTEN DIMENSIONS ON DRAWINGS GOVERN. DO FEE AND ANY OTHER REGUIRED FEES BATTERY BACK -UP. NOT SCALE DRAWIN65. DETAILS TAKE AND PERMITS. PROVIDE COPPER PRECEDENCE OVER SMALLER SCALE DRAWIN65. CIRCUIT WIRING THROUGHOUT.. 7. ALL NEW ELECTRICAL FIXTURES TO DRAWINGS AND SPECIFICATIONS ARE INTENDED TO RUN TO EXIST 5WITCHIN6 UNLESS AGREE. GENERALLY, SPECIFICATIONS WILL TAKE INDICATED OTHERWISE PRECEDENCE OVER DRAWINGS. SHOULD ANY DISCREPANCIES OCCUR, CONTRACTOR SHALL NOT PERFORM ANY WORK UNTIL RESOLVED BY THE ARCHITECT. WORK 5HOWN ON DRANINC75 BUT NOT IN SPECIFICATION OR SHOWN IN SPECIFICATIONS BUT NOT ON THE DRAWINGS: SHALL BE PROVIDED AS IF SHOWN ON BOTH. NO DEVIATIONS, CHANCaE5, SUBSTITUTIONS, ETC IN THE DOCUMENTS 5HALL BE MADE WITHOUT WRITTEN APPROVAL FROM THE ARCHITECT. IN THE CASE OF 'CONFLICTS BETWEEN OR WITHIN THE DRAWINGS AND SPECIFICATIONS., THE GREATER OUANTITY, HIGHER QUALITY, ETC' WORK SHALL BE PROVIDED AT NO ADDITIONAL G05T. C. PROJECT COQRDlNATiON 1. ALL CONTRACTORS AND SUBCONTRACTORS RESPONSIBLE FOR FOR WORK 5HOWN IN THE SPEGIFIGATIONS AND ON THE DRAWINGS SHALL JOINTLY AND SEPARATELY COORDINATE THEIR WORK WITH RE6ARD'TO 50HEDULIN6, INSTALLATION PROCEDURES, SHOP DRAWINGS AND INSTALLATION OF ALL RELATED MATERIALS., EXIST CEILING -NO YYORK EXIST CEILI46- NOAORK EX $ 5/6 M'fL EX 8 "5/6 MTL " STUDS 0 16" OC STUD9 "® 16 EX 5/6° TYPE 'X' VA EX 5lp`TYPE 'X' ON 5/9 TYPE 'X' DIN AT RIGHT AN6LE CEMENTITIOUS SAC,}CE TO "EA SIDE OF STUDS ATTACHED ")v / 1� " ` APPLIED" PARALLEL OR " TYPES DW SCREM 0 8" OC m" 1JERT "JO1N75, ' . ,. TO '8711175• W_ ! "1/4 "" TYPE i I2Voe_ a FLOOR 3 " GL6 RUNT 125' d 1NTERMEDIPTE."- V 0" OO=YERT(GAL :JOINT STUDS- JOINTS STA66ERM 24" ON EA SIDE 4 " ON OPPOSITE SIDES " ON OPF051TE SIDS BATT INSUL ESC SA7T.INSUL" BASE AS 5CHEDULED SASE "A5 SCHEDULED P2 -1 HR GA #WP 'I''0 72 ' GA #WP 1002 IIOV. GtUADRAPLEX RECEPTACLE � IIOV. DUPLEX RECEPTACLE GROUND FAULT INTERRUPTING RECEPTACLE 220 220 VOLT RECEPTACLE GROUND FAULT INTERRUPTING 4 6FI WATER PROOF RECEPTACLE � SPLIT WIRED RECEPTACLE FLR FLOOR RECEPTACLE/VERIFY FINAL LOCATION OVERHEAD DOOR OPENER /RECEPTACLE SWITCH THREE -WAY SWITCH 54 FOUR -WAY 5WITGH �0 5WITGH W/ DIMMER OMD MOTION DETECTOR 60 GARBAGE D I SP05AL D DOORBELL TELEPHONE JACK qr� DEDICATED PHONE LINE [J GABLE TELEVISION CLOCK TYPE OUTLET .JUNCTION BOX - DIRECT WIRED FIXTURE /APPLIANCE ❑ KEYED PLAN NOTES: I, REMOVE EXIST SOFFIT ABOVE CABINETS 2. REMOVE EXIST DOOR, FRAME AND WALLS -WATCH ADJACENT CON5TR TO MATCH EX 15T 5. REMOVE EXIST FLOORING, TILE SURROUND ® TUB, ALL FLUMBIBG FIXTURES $ AC0E50RIE5, LIGHTING AN D CABINETS. PREP EXIST SURFACES AS Rr=aV FOR NEW FINISHES. PROVIDE CEMENT BACKER BD @ NEW 5HOWER 4. REMOVE EXIST WALL5 COMPLETE AS 5HONN -PATCH ADJACENT SURFACES TO MATCH EXIST 5. NEW SHOWER-TIE INTO EXIST DRAIN- PROVIDE T EMP 6LA55 DOOR AND ENCLOSURE C ;ENERAL. ZE COL.1T10N NOTES: 1. ALL DEMOLITION WORK TO COMPLY WITH ALL CODES, ORDINANCES, RULES, REGULATIONS ETC, AS READ BY ALL AUTHORITIES HAVING JURISDICTION, 2. GC TO COORDINATE NOISY AND /OR DISRUPTIVE DEMOLITION WORK WITH OWNER PRIOR TO START OF WORK 3. GC 15 TO FIELD VERIFY ALL EXIST CONDITIONS AND COORDINATE WITH ORIGINAL BUILDING DRAWINGS AND FIELD CONDITIONS. 4. GC 15 TO FIELD VERIFY ALL EX151TNG PLUMBING, ELECTRICAL, ETC FROM ABOVE AND RELOCATE AS REOD FOR NEW CONSTRUCTION -GC 15 TO NOTIFY OWNER "72 HOURS IN ADVANCE OF ANY SERVICE DISRUPTIONS. 5. GENERAL CONTRACTOR 15 RESPONSIBLE FOR ALL 5HORIN6 INCLUDING DE516N,' INSTALLATION AND REMOVAL. �}SD f , may° -- -- '"� ( SG V/P 0 ( D L LLJ_ � U DW L_IV1NC7 /D INING REF E EI/��*.1 00 I I E2 L 0 0 f'- L A N 5 U "N'l T #2I 1/4 11 _ 011 EXIST WALL TO REMAIN Town i. valt I%Opy O FFIC E PO 'Box 1492 tel: 970- 479 -7387 Vad, CO 81698 fax: 970- 476 -0077 2008 TrD achstects, sic. All rights rescrvcd CONSULTANTS: ISSUE: JULY 22,200a -BLDG PERMIT L r V N ® ® W N 0 1 J 2 �} # t d1 3 # > 1 � � 0 A - o REF�� � O I V/P 0 ( D L LLJ_ � U DW L_IV1NC7 /D INING REF E EI/��*.1 00 I I E2 L 0 0 f'- L A N 5 U "N'l T #2I 1/4 11 _ 011 EXIST WALL TO REMAIN Town i. valt I%Opy O FFIC E PO 'Box 1492 tel: 970- 479 -7387 Vad, CO 81698 fax: 970- 476 -0077 2008 TrD achstects, sic. All rights rescrvcd CONSULTANTS: ISSUE: JULY 22,200a -BLDG PERMIT Ub1'IMUMd" "' 0 1 MRS& I II� W N 0 - J Q � � 0 � (3 O ( S) v Ub1'IMUMd" "' 0 1 MRS&