Loading...
HomeMy WebLinkAboutBlower Door Test Results_Ashton Hirst_4193 Spruce Way.pdfBUILDING LEAKAGE TEST N1102.4.1.2 (R402.4.1.2) Deeper Green Consulting Frisco, CO 80443 Website: www.deepergreenconsulting.com Date of Test: 9/10/2018 Test File: 4193A Spruce Way Technician: Matt Wright Project Number: Customer:Ashton Hirst Construction Building Address:Spruce Way Duplex 4193A Spruce Way Vail, CO 81657 Test Results 1.Airflow at 50 Pascals:1527 CFM50 (50 Pa = 0.2 w.c.)2.82 ACH50 2.Leakage Area:84.0 in2 LBL ELA @ 4 Pa 3.Building Leakage Curve:Flow Coefficient (C) = 120.1 Exponent (n) = 0.650 (Assumed) 4.Test Settings:Test Standard: RESNET One-Point Test Test Mode: Depressurization 5.Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1.Estimated Average Annual Infiltration Rate:96.9 CFM 0.18 ACH 19.4 CFM per person 2.Estimated Design Infiltration Rate:Winter:160.5 CFM 0.30 ACH Summer:109.3 CFM 0.20 ACH Cost Estimates 1.Estimated Cost of Air Leakage for Heating:$ 117 per year heating 2.Estimated Cost of Air Leakage for Cooling: Mechanical Ventilation Guideline (based on ASHRAE 62.2-2010) Recommended Whole Bldg Rate:65.9 CFM Base Rate:65.9 CFM BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 9/10/2018 Test File: 4193A Spruce Way Building Information Volume 32466.0 Surface Area Floor Area 2844.0 Height 35.0 # of Bedrooms 4 # of Occupants 5 Year of Construction 2018 Wind Shield M Location Climate Information Ventilation Weather Factor 0.80 Energy Climate Factor 19.00 Heating Degree Days 7850 Cooling Degree Days 28 Design Winter Wind Speed 1.6 mph Design Summer Wind Speed 10.9 mph Design Winter Temp Diff 77 deg F Design Summer Temp Diff 11 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost $0.70/ccf Heating Efficiency %95.00 Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) 25958 4/6/2018 Micromanometer Energy Conservatory DG700 29536-7-700 4/6/2018 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 9/10/2018 Test File: 4193A Spruce Way Depressurization Test: Environmental Data Indoor Temperature (°F) Outdoor Temperature (°F) Altitude (ft) 66.0 77.0 8400.0 Baseline Pressure Data Baseline 1 (Pa)0.0 Baseline 2 0.5 Baseline 3 -0.1 Baseline 4 -0.1 Baseline 5 0.0 Average Baseline (Pa)0.1 Baseline Range (Pa)0.6 Data Points - Collected using iTEC RESNET 100 - Data Entered Manually Nominal Building Pressure (Pa) Baseline Adjusted Building Pressure (Pa) Fan Pressure (Pa) Nominal Flow (cfm) Adjusted Flow (cfm) Fan Configuration -51.8 -51.9 66.3 1469 1564 Ring A Time Averaging Period: 10.0 Deviations from Standard RESNET One-Point Test - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 9/10/2018 Test File: 4193A Spruce Way Comments GeoTag Location Information: - Longitude: -106.29971 - Latitude: 39.63870 Time Stamp: 09/10/2018 02:33 PM