Loading...
HomeMy WebLinkAboutcut sheets_46.pdf11/17/16 PROPOSAL SUBMITTED TO: NAME: Xcel Energy Attn. Howard Cheney MAILING ADDRESS: CITY: STATE: ZIP: CELL: - EMAIL: howard.j.cheney@xcelenerqy.com WORK TO BE PERFORMED AT: LOCATION: Pump/Electrical House ADDRESS: Matterhorn Bridge CITY: Vail STATE: CO ZIP:81657 lob No. R-6463 ALL MATERIAL IS GUARANTEED TO BE AS SPECIFIED, AND THE WORK TO BE PERFORMED IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS SUBMITTED AND COMPLETED' IN A WORKMAN LIKE MANNER. Upon acceptance of proposal, please sign and fax back to 970-328-2077 P.O. BOX 2123, Eagle, CO 81631Telephone970-328-2340 Fax 970 328-2077 1 Cont...-actot•s, Inc. SCOPE OF WORK JOB# R-6463 The Following proposal is for the Residence located at Matterhorn Bridge, Vail. This is based upon a walk through with Eddie Leiva. TCC proposes to do the following Roof Work -TCC to provide labor and materials to remove existing cedar shake roof and install a Metal Roof System. -TCC will remove cedar shakes, clean exposed roof areas and replace any damaged underlayment's such as plywood if needed. -TCC will manufacture and install Painted Metal Flashings to eave, rake. Color TBD 8JeOW/\/ . -Provide and install GRACE Ice and Water Shield HT to exposed roof areas for proper waterproofing. -Manufacture and install a 24GA Painted Metal Standing Seam Roof System to exposed roof areas. Color TBD /3 e&w N . -Estimated Cost ................... _ ......................................................................... $4, 8 50. 00 CONDITIONS: 1. Please be advised that materials for this proposal have been bid at current market prices and cannot be guaranteed past 30 days. 2. Payment is due upon receipt of Invoice. Any past due amounts are subject to a 3.5%/month Interest charge. Property subject to have a LIEN filed if not paid with in 60 days from last day worked at job site. 3. WINTER CONDITIONS CLAUSE: Proposal does not indude ice and snow removal, if needed this will be billed on a cost plus basis. 4. WARRANTY: TCC Contractors Inc. will warranty all labor against leaks for a period of 60 days. Warranty Is void if snow exceeds 24" and is not removed. Snow removal performed by anyone other than TCC Contractors Inc. or other local, properly insured contractor will void warranty. 5. INSURANCE: TCC Contractors Inc. is fully insured with liability Insurance In the amount of $2,000,000 and workman's compensation. Certificates of Insurance will be forwarded to client upon acceptance of proposal. ACCEPTANCE OF PROPOS __________ 11/17/16 Eddie Leiva, Estimator/Project Manager 0 ZED REPRESENTATIVE DATE I /-115"" -.,,1. Cl/ -6 P.O. BOX 2123, Eagle, CO 81631Telephone970-328-2340 Fax 970 328-2077 2 PAC-CLAD' PETERSEN ALUMINUM A*CARDINAL RED A*COLONIAL RED BURGUNDY A*TERRACOTTA A*STONE WHITE A*GRANITE A*SANDSTONE A* MEDIUM BRONZE A* DARK BRONZE A*SLATE GRAY A* BONE WHITE A*MUSKET GRAY A*CHARCOAL MIDNIGHT BRONZE MATIEBLACK INTERSTATE BLUE A* HEMLOCK GREEN A* ARCADIA GREEN A*PATINA GREEN A*HUNTER GREEN A*MILITARY BLUE AWARD BLUE HARTFORD GREEN FOREST GREEN A *EVERGREEN Kynar 500" or Hylar saaa· pre-finished steel and aluminum for roofing, curtainwall and storefront applications. • Denotes PAC-CLAD Metallic Colors * Denotes ENERGY STAR colors A Denotes PAC-CLAD Cool Colors *BERKSHIRE BLUE A *SLATE BLUE See back for color availability chart. Note: Midnight Bronze available in .040 aluminum only. PAC-CLAD" Metallic Colors ••*COPPER PENNY e A* AGED COPPER PETERSEN ALUMINUM CORPORATION HQ: 1005 Tonne Road Elk Grove Village, IL 60007 P: 800-PAC-CLAD F: 800-712-7150 9060 Junction Drive Annapolis Junction, MD 20701 P: 800-344-1400 F: 301-953-7627 WWW .PAC-CLAD.COM 10551 PAC Road Tyler, TX 75707 P: 800-441-8661 F: 903-581-8592 •A*CHAMPAGNE 102 Northpoint Parkway Acworth, GA 30102 P: 800-272-4482 F: 770-420-2533 e A*WEATHERED ZINC 1885 Station Pkwy NW, Ste B Andover, MN 55304 P: 877-571-2025 F: 866-901-2935 PAC-CLAD REFLECTIVITY EMISSIVITY 3 YEAR SRI STEEL ALUMINUM ENERGY STANDARD COLORS EXPOSURE 24 GA 22 GA 032 U40 05. DG3 STAR' ALMOND ARCADIA GREEN BONE WHITE CARDINAL RED CHARCOAL CITYSCAPE COLONIAL RED DARK BRONZE EVERGREEN GRANITE* HEMLOCK GREEN HUNTER GREEN MANSARD BROWN MEDIUM BRONZE MILITARY BLUE MUSKET GRAY PATINA GREEN SANDSTONE SIERRA TAN SLATE BLUE SLATE GRAY STONE WHITE TEAL TERRA COTTA PAC-CLAD METALLIC COLORS AGED COPPER CHAMPAGNE COPPER PENNY SILVER WEATHERED ZINC ZINC 0.53 0.31 0.67 0.37 0.27 0.44 0.32 0.26 0.27 0.32 0.29 0.27 0.29 0.26 0.29 0.31 0.33 0.49 0.36 0.25 0.37 0.64 0.26 0.36 0.26 0.40 0.47 0.49 0.26 0.33 0.87 0.88 0.86 0.86 0.87 0.86 0.88 0.85 0.86 0.87 0.86 0.86 0.86 0.88 0.87 0.87 0.86 0.87 0.87 0.87 0.88 0.87 0.87 0.88 0.87 0.82 0.87 0.81 0.82 0.88 PAC-CLAD STANDARD COLORS (DO NOT MEET COOL RDOF REQUIREMENTS) AWARD BLUE BERKSHIRE BLUE* BURGUNDY FOREST GREEN HARTFORD GREEN INTERSTATE BLUE MATTE BLACK MIDNIGHT BRONZE 0.26 CLEAR-COAT ACRYLIC FINISH (NDN-KYNAR) GALVALUME PLUS 0.68 0.87 0.14 0.52 0.32 0.64 0.36 0.27 0.43 0.32 0.24 0.25 0.33 0.30 0.26 0.27 0.25 0.28 0.30 o.n 0.49 0.36 0.24 0.36 0.61 0.26 0.35 0.25 0.36 0.44 0.46 0.23 0.32 0.25 0.55 62 32 81 39 27 49 34 24 26 33 29 26 29 26 29 n 34 56 39 24 40 77 25 39 25 42 53 54 23 35 25 57 * * * * * * * * * • * * * • * * * * • * • * * * * PAC-CLAD0 Metallic finishes are available from stock at a moderate extra wst. PAC-<:lAD• Copper Penny is a Non-Weathering finish. Solar Reflectance Index calculated according to ASTM E-1980. "Low Gloss/Low Sheen.full Kynar soo• or Hylar sooo• finish Energy Sta ... Performance Criteria: Emissivity uses ASTM CBn. Reflectivity uses ASTM Cl549. Technical Data for Kynar soo•/Hylar sooo• Coating: > South Florida Exposure: Color (ASTM D 2244) -No more than 5dE Hunter units at 20 years; Chalk (ASTM D 4214) -Rating no less than 8 at 20 years; Film integrity -20 years. > Accelerated Weathering (ASTM D 4587, ASTM G 154): 5000 Hours. QUV-A, 340 NM Bulb -Chalk, per ASTM D 4214, rating of 6 or better; Color, per ASTM D 2244, < 5dE (Hunter Units) color change. > Humidity Resistance (ASTM D 2247): Galvalume or HOG, 100% RH, 2000 hours -No field blisters: Aluminum, 100% RH, 3000 hours -No field blisters > Salt Spray Resistance (ASTM B 117): Aluminum, 3000 hours, Galvalume or HOG, 1000 hours -Creep from scribe no more than 1/16', no field blisters > Chemical/Acid Pollution Resistance (ASTM D 1308): Pass > T-Bend (ASTM D 4145): 1T -3T with no loss of adhesion > Pencil hardness (ASTM D 3363): HB -28 > Specular Gloss (ASTM D 523)@ 60 degrees: Typical -20 -35 > Abrasion Resistance (ASTM D 968): 65 +/-10 liters > Cross Hatch Adhesion (ASTM D 3359): No loss of adhesion > Reverse Impact (ASTM D 2794) Galvalume or HOG, 2x metal thickness inch-pounds, no loss of adhesion; Aluminum, l.Sx metal thickness inch-pounds, no loss of adhesion > Flame Test (ASTM E 84): Class A Coating > Water Immersion (ASTM D 870): 500 hours, 100 degrees, no loss of adhesion Samples: These color reproductions are as accurate as modern printing technology will permit. Free material samples are available on request. Recycled Content: For information on recycled content, contact your PAC representative or visit www.pacgreeninfo.com PAC-CLAD' is a registered trademarl< of Petersen Aluminum Corporation, Kynar soo• 1s a registered trademark of Ett Atochem North America, Inc Hylar sooo• is a registered trademarl< of Ausimont USA. 9/1015 Our DMC 150SS roof system will lend striking dimension to any architectural design. This versatile 1-1 /2" mechanically seamed panel can be curved to a wide range of radiuses and applications -from barrel roofs to conical shapes and more. Concealed fasteners and a floating clip system reduce the effect of thermal stresses on the panels, helping to maintain a beautifully smooth, uniform appearance despite fluctuations in temperature. Ideal Application: Commercial Residential Single lock panel Double lock panel Available widths: 12', 14', 16', 18', 19' or 20'* *Drexel Metals design pressures, wind uplifts and test reports are for specific deck attachments, material gauges. clip spacing and panel widths. A complete specification and listing is available online at www.drexelmetals.com Substrates available: • Galvalume• -24ga and 26ga • Drexlume• -24ga and 26ga • Aluminum -.032' • Copper -16 oz and lead-coated copper • Falzinc Profile Options: • Single lock panel • Double lock panel •Radius panel (single or double lock) Finishes and product warranty: Available in a variety of coatings and colors by AkzoNobel. See the Drexel Metals color card fo~ ,. / standard colors and paint J I' specifications. AkzoNobel T~Ane-."'81"51'odao, Production options: Installation: Can be installed over steel decking with Polylso, or over plywood decking and Drexel Metals MetShield• underlayment. Slope: Minimum slope 2:12 Testing: In accordance with: (i@"V 11 L 111 ,...-cD ,__,_COUNTY. ull .. .. --Sl~lllmkt.ooldl www .drexelmetals.com Unseamed panel Galvalume• Substrate: High-performance painted metal roofing product, carefully tensioned leveled for superior flatness. 35YEAR WARRANTY 35-Year Non Pro-rated PVDF Paint Warranty Single lock panel Aluminum Substrate: High-performance painted metal roofing product, carefully tensioned leveled for superior flatness. 35YEAR WARRANTY 35-Year Non Pro-rated PVDF Paint Warranty Factory made or field rolled to exact lengths Optional: striation, beads, pencil ribs - Minimum Roof Pitch: 2:12-low roof pitch Double lock panel Drexlume• Substrate: Mill finished Galvalume• with a two-sided, clear acrylic finish. 25 YEAR WARRANTY 25-Year Non Pro-rated Drexlume Warranty (Acrylic Coated Galvalume) MetShield L!.!..1~1.U..!.!!.£.!.U • UL 580 Wind Uplift (Class 90) • ASTM E1646 Water Infiltration • TAS 125 Wind Uplift •UL 1897 Extended Phase Wind Uplift •UL 2218 Class 4 Hail Impact • UL 790 Class A Fire Rating • UL Environmental - SRI Third Party Verified • TAS 100 Wind Driven Rain • ASTM E1680 Air Infiltration • ASTM E1886 Missile Impact • ASTM 2140 Static Pressure Water Head • Miami-Dade County Approved • Florida Building Code Approved •Texas Department of Insurance Approval 1234 Gardiner Lane, Louisville, KY 40213 888-321-9630 toll-free • 502-690-6174 fax -· ....... C2013 Drexel MetaJs, Inc, All rights reserved. Galvalume• is a registered trademark of BEIC International. Inc. Orexlume• is a trademark of Drexel Metals, Inc. ENERGY STAR name and logo are registered U.S. marks and are owned by the U.S. government. Colors shown represent the actual color as closely as possible. To enStXe exact color tor tnal approval, a metal color chip is available. warranty statements mentioned are ouUines: complete Limited warranty information is available on request. No olhef warranty expressed or implied is appicabte.