HomeMy WebLinkAboutB17-0393_CENTERLINE_DN13XC415_2.5 100% CDs_09.12.17 stamped 9_1507756500.pdfHFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX HFLEX
HFLEX HFLEX HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX
HFLEX HF LEX HFLEX
H FLEX
HFLEX
HFLEX
3
1
(1) (N) SPRINT 2.5 ANTENNA
ON (N) MOUNT EACH SECTOR
(RE:4/A5.0)
4 ANTENNA / ANCILLARY SCHEDULE AND NOTES
2
ANTENNA SPECS
SHEET NO.
SITE ADDRESS:
SITE NAME:
169 N. FRONTAGE RD
VAIL, CO 81657
US WEST COMM
TOWER
DN13XC415
SUBMITTAL
NO.
PRELIMINARY
DATE
DESCRIPTION
D/C
SG/ML
0
1
90% CD REVIEW
07-14-17
NO. DATE DESCRIPTION
D/C
SG/ML 90% CD REV B
08-28-17 2
SG/ML 100% CONST.
09-12-17 3
SG/ML 90% CD REV A
08-04-17
SHEET TITLE
TM
R
0'
20'
SCALE: 3/32" = 1'-0" (11X17)
SCALE: 3/16" = 1'-0" (22X34)
10'
SCALE: NTS
SCALE: NTS
SCALE: NTS
SCALE: NTS
NOT TO SCALE
ANTENNA PLAN
AND DETAILS
A4.0
NOTES:
1. STRUCTURAL ANALYSIS MUST BE PERFORMED ON ALL ROOFTOPS, FLAGPOLES AND TOWER SITES BEFORE INSTALLATION OF NEW ANTENNAS, NEW RRHs, & NEW
CABINETS/TEMPORARY PLATFORM. STRUCTURAL ANALYSIS PROVIDED BY GENERAL DYNAMICS.
2. EXISTING ANTENNAS ARE CDMA UNLESS NOTED OTHERWISE.
3. NEW SPRINT ANTENNAS INCLUDE RESPECTIVE RRHs WHICH SHALL BE MOUNTED ON THE PIPE BEHIND THE ANTENNA SIMILAR TO THAT SHOWN ON DETAIL 7, SHEET A-6.
4. FIELD VERIFY EXISTING AZIMUTH BEFORE RELOCATING THE ANTENNA, IF REQUIRED. PRIOR APPROVAL FROM SPRINT TO BE GRANTED BEFORE RELOCATION OF ANTENNAS.
5. ALL AZIMUTHS ARE TO BE ESTABLISHED CLOCKWISE FROM THE TRUE NORTH HEADING. CONTRACTOR SHALL VERIFY NEW ANTENNA RAD CENTER AND ORIENTATIONS
WITH SPRINT PCS PRIOR TO INSTALLATION OF ANTENNAS. PRIOR TO ATTACHING ANTENNAS AND MOUNTING SECTIONS, EXISTING TOWER AND TOWER FOUNDATION MUST
BE ANALYZED BY A LICENSED STRUCTURAL ENGINEER TO VERIFY TOWER IS CAPABLE OF SUPPORTING THE NEW LOADS. REFER TO STRUCTURAL ANALYSIS BY OTHERS.
CONTRACTOR SHALL REFER TO TOWER STRUCTURAL CALCULATIONS FOR ADDITIONAL LOADS. NO ERECTION OF MODIFICATION OF TOWER SHALL BE MADE WITHOUT
APPROVAL OF STRUCTURAL ENGINEER.
LENGTH
WIDTH
DEPTH
SIDE VIEW FRONT VIEW
TOP VIEW
ANTENNA DATA
MECHANICAL SPECIFICATIONS
MANUFACTURER HEIGHT WIDTH DEPTH WEIGHT
PART # ET-X-WM-18-65-8P
KMW 61" 12" 4.3" 36.4 LBS
0'
20'
SCALE: 3/32" = 1'-0" (11X17)
SCALE: 3/16" = 1'-0" (22X34)
10'
EXISTING ANTENNA PLAN
NEW ANTENNA PLAN
(E) BETA
SECTOR
AZIMUTH = 180°
(E) GAMMA SECTOR
AZIMUTH = 270°
(E
) ALPHA SECTOR
AZIMUTH = 108°
2.5 RRU / HYBRID CABLE SCHEDULE
SECTOR RRU MODEL RRU FREQUENCY
HYBRID CABLE
LENGTH
HYBRID CABLE
DIAMETER
JUMPER
SIZE
JUMPER
LENGTH
RET
LENGTH
RET CABLE
MANUFACTURER
RET CABLE
MODEL NUMBER
ALPHA RRH-B8 2500 MHz (E) (E) 1/2" 15' 15' COMMSCOPE iRET AISG V1.1
BETA RRH-B8 2500 MHZ (E) (E) 1/2" 15' 15' COMMSCOPE iRET AISG V1.1
GAMMA RRH-B8 2500 MHZ (E) (E) 1/2" 15' 15' COMMSCOPE iRET AISG V1.1
NEW ANTENNA SCHEDULE
SECTOR
ANTENNA
FREQUENCY
ANTENNA
MANUFACTURER
ANTENNA MODEL ANTENNA QTY. AZIMUTH
RAD
CENTER
ANTENNA
SIZE
ELECT. TILT
800/1900
MECH.
TILT
ALPHA 2500 MHz KMW ET-X-WM-18-65-8P 1 108° 99'-0" 61" TBD 0°
BETA 2500 MHz KMW ET-X-WM-18-65-8P 1 180° 116'-0" 61" TBD 0°
GAMMA 2500 MHz KMW ET-X-WM-18-65-8P 1 270° 97'-0" 61" TBD 0°
(2) (E) SPRINT NV
800/1900 RRUs PER
SECTOR TO REMAIN
(1) (E) SPRINT
NV ANTENNA
PER SECTOR
TO REMAIN
(3) (E) SPRINT HYBRIFLEX CABLES TO
REMAIN (1) PER SECTOR
(2) (E) SPRINT NV 800/1900 RRUs PER
SECTOR TO REMAIN
(3) (E) SPRINT HYBRIFLEX CABLES
TO REMAIN (1) PER SECTOR
(1) (N) SPRINT 2.5 RRU PER
SECTOR ON (N) UNISTRUT
MOUNT (RE:2/A5.0)
(1) (E) SPRINT
LEGACY ANTENNA
TO BE REPLACED
(TYP EACH SECTOR)
(1) (N) PIPE MOUNT TO
REPLACE (E) FOR ALL (N)
SPRINT 2.5 ANTENNAS EACH
SECTOR (RE:3/A5.0)
29'-10"
25'-1"
22'-0"
3
6'-7"
22'-1"
(N) BETA
SECTOR
AZIMUTH = 180°
(N) GAMMA SECTOR
AZIMUTH = 270°
(
N) ALPHA SECTOR
AZIMUTH = 108°
29'-10"
25'-1"
22'-0"
3
6'-7"
22'-1"
9'-6"6'-4"14'-1"
5'-8"6'-6"
7'-5"7'-2"5'-10"9'-1"
17'-1"
09/20/2017
10/11/17