ISSUE LOG KEY:
# DATEISSUE LOG
MECHANICAL SHEET INDEX
TITLE
GENERAL MECHANICAL INFORMATIONME0.1 PERMIT11.17.2017
ISSUED AS PART OF A SET
' ' NOT PART OF SET
' ' ISSUED FOR INFORMATION ONLY*
√
√
√
MECHANICAL-ELECTRICAL PLANSME2.1
NOTES
1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONS
ON LEGEND SHEET ARE NOT NECESSARILY USED ON
THIS PROJECT.
2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN
PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES AND
NOTATION CONVENTIONS OCCURRING IN THIS
DRAWING SET ARE NECESSARILY DEFINED ON THESE
LEGENDS. CONSULT THE ENGINEER IN THE EVENT
SYMBOLOGY OR NOTATION INTERPRETATION IS
REQUIRED.
ABOVE SEA LEVEL
PROJECT ALTITUDE
8,150'
SPECIFICATIONS:
1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK.
2. REVIEW ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND OTHER DRAWINGS PRIOR TO BID.
3. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT.
4. SUBCONTRACTORS SHALL BE RESPONSIBLE TO NOTIFY THE PRIME CONTRACTOR OF DISCREPANCIES OR CONFLICTS IN THE CONSTRUCTION
DOCUMENTS FOUND DURING BIDDING AND/OR PRIOR TO PERFORMING THE WORK.
5. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND
ORDINANCES.
6. PROVIDE PERMITS AND INSPECTIONS REQUIRED.
7. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A
PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER.
8. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION.
9. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF
DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND
MATERIALS AS REQUIRED TO MAINTAIN AND/OR RESTORE CONTINUITY OF EXISTING SYSTEMS.
10. PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT.
11. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE
ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION.
12. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS
NECESSARY AT NO COST TO OWNER.
13. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. FOR HID FIXTURES AND WIRING WITHIN 3 INCHES OF FLUORESCENT
BALLASTS WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30
DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. 600 VOLT ALUMINUM WIRE
AND CABLE IN SIZES 1/0 AND LARGER MAY BE SUBSTITUTED FOR COPPER ON SERVICES AND FEEDERS IF AMPACITY IS EQUAL TO OR
GREATER THAN COPPER, AND VOLTAGE DROP IS EQUAL TO OR LESS THAN COPPER AND SHALL BE TERMINATED AT SWITCHES, LUGS, CIRCUIT
BREAKERS, ETC., WITH MAC-ADAPT SERIES "MPT" MACHINE COMPRESSION ADAPTERS OR EQUAL.
14. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER
THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION.
15. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY.
16. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT BREAKERS, SAFETY SWITCHES, AND ALL OTHER ELECTRICAL APPARATUS
SHALL BE LISTED AS SUITABLE FOR 75 DEGREE CELSIUS.
17. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 15 AMPERES FOR DUPLEX
RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT.
18. DEVICES SHALL BE AS FOLLOWS:
A. RECEPTACLES - MATCH EXISTING OR HUBBELL NUMBER 5262 SERIES
B. COVER PLATES SHALL EXISTING IN OTHER OFFICES OR AS SELECTED BY ARCHITECT. PROVIDE COVER PLATES FOR SWITCHES,
RECEPTACLES, TELEPHONE, TELEVISION, COMPUTER, AND J-BOX OUTLETS AS REQUIRED.
19. FIXTURES RECESSED IN "T-BAR" CEILING SHALL BE SUPPORTED INDEPENDENTLY OF CEILING SYSTEM, WITH FOUR NUMBER 12 HANGER WIRES
UP TO STRUCTURE. SECURE HANGER WIRES TO CORNERS OF FIXTURE. CLIP FIXTURE TO GRID ON TWO SIDES WITH FACTORY-FURNISHED
CLIPS. FINAL CONNECTION TO FIXTURE SHALL BE MADE WITH A FLEXIBLE U.L. APPROVED ASSEMBLY.
20. ALL DUCTWORK, DIFFUSERS, PIPING, FIXTURES, AND EQUIPMENT SHOWN IN LIGHT LINE WEIGHT IS EXISTING, NEW INDICATED BY HEAVIER
LINE WEIGHT, EXCEPT WHERE NOTED. PIPES, DUCTWORK, EQUIPMENT, ETC. TO BE REMOVED, ARE SHOWN HATCHED.
21. OFFSET PIPING, DUCTWORK, ETC. AS NECESSARY TO ACCOMMODATE STRUCTURE, BEAMS, AND COLUMNS, AND EXISTING EQUIPMENT.
22. FIRE STOPPING REQUIREMENT. PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF
PREVENTING THE PASSAGE OF FLAMES AND HOT GASSES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC FOR
FIRE STOPS ASTM-E-814. ACCEPTABLE MATERIALS INCLUDE: DOW CORNING RTV FIRE STOP FOAM FOR BARE PIPE, METAL CONDUIT, AND
ELECTRICAL CABLE; 3M FIRE DAM 150 CAULK FOR BARE PIPE, METAL CONDUIT, AND BUILDING CONSTRUCTION GAPS; 3M CP-25 CAULK AND
FS-195 INTUMESCENT STRIPS FOR INSULATED PIPES, PLASTIC PIPE OR CONDUIT, AND ELECTRICAL CABLE. SUBMIT UL LISTED APPLICATION
DATA FOR EACH TYPE OF PENETRATION ENCOUNTERED.
26. FIRE PROTECTION DESIGN/BUILD REQUIREMENTS:
A. REVIEW AND REVISE EXISTING SPRINKLER SYSTEM. RELOCATE EXISTING OR ADD NEW SPRINKLER HEADS AS REQUIRED IN ACCORDANCE
WITH NFPA 13, ALL APPLICABLE CODES AND ORDINANCES AND PROJECT REQUIREMENTS.
B. SYSTEM SHALL BE INSTALLED COMPLETE AND OPERATIONAL, INCLUDING WATER FLOW INDICATOR, CONNECTIONS TO EXISTING ALARM,
DRAIN PIPING, IDENTIFICATION SIGNS, ETC.
C. WORK SHALL BE PERFORMED BY A QUALIFIED FIRE SPRINKLER INSTALLER WITH A MINIMUM OF FIVE (5) YEARS' EXPERIENCE IN SIMILAR
INSTALLATIONS.
D. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO AND DURING INSTALLATION.
TV OUTLET DIAGRAM
NOTES:
1. PROVIDE LEVEL 1 ADMINISTRATION PER
ANSI/TIA/EIA-606.
2. PROVIDE LABEL ON FRONT OF FACEPLATE.
MODULAR CAT6 CONNECTOR
(BLUE). TERMINATE T568B.
F-CONNECTOR, FEMALE
PASS-THROUGH.
2-PORT MODULAR COMMUNICATIONS
FACEPLATE, COLOR TO MATCH
RECEPTACLES.
4PR CAT6 UTP CABLE
(BLUE JACKET).
1" C.
SERIES 6 (RG6/U) CABLE
(GREEN JACKET).
NO SCALE
OUTLET LABEL
OUTLET LABEL
DATA OUTLET DIAGRAM
MODULAR CAT6 CONNECTOR
(BLUE). TERMINATE T568B.
BLANK MODULAR INSERT,
MATCH FACEPLATE COLOR.
2-PORT MODULAR COMMUNICATIONS
FACEPLATE, COLOR TO MATCH
RECEPTACLES.
4PR CAT6 UTP CABLE
(BLUE JACKET).
NO SCALE
OUTLET LABEL
OUTLET LABEL
NOTES:
1. PROVIDE LEVEL 1 ADMINISTRATION
PER ANSI/TIA/EIA-606.
2. PROVIDE LABEL ON FRONT OF
FACEPLATE.
1" C.
NO SCALE
TYPICAL DEVICE ALIGNMENT
EQ EQ
6"MIN.
℄
℄
℄
DOOR WINDOW
EQ EQ
℄LIGHTING
CONTROL
℄
℄
OFFSET COMMUNICATIONS
DEVICES FROM POWER
DEVICES TO EITHER
OPPOSITE SIDE OF STUD BAY,
OR ADJACENT STUD BAY.
NOTES:
1. IF ALIGNMENT OF DEVICES INDICATED HERE IS IN CONFLICT
WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA
DIMENSIONS SHALL GOVERN.
2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS.
LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL
SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS
SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT.
EQ
BACKSPLASH
ABOVE
COUNTER
DEVICE
RECEPTACLE
COUNTERTOP
EQ
FINISHED FLOOR
FINISHED CEILING
6"
MIN.
20"
MAX.
ALIGN DEVICES (OUTLETS,
CONTROLS, ETC.)
VERTICALLY. DO NOT
VERTICALLY ALIGN POWER
AND COMMUNICATIONS
DEVICES SIMULTANEOUSLY.
18"
78"
48"
ELECTRICAL DEVICES
NOTES:
1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS
DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN.
2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR
ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON
INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT.
NO SCALE
TYPICAL DEVICE MOUNTING HEIGHTS
S
TOP OF CABINET
TOP OF DEVICE
CL OF DEVICE
FINISHED FLOOR
FINISHED CEILING
PLAN SYMBOLS & ABBREVIATIONS
THERMOSTATT
TELEVISION OUTLET - WALL MOUNTEDTV
VARIABLE VOLUME BOXVV
VARIABLE VOLUME BOX W/ REHEATVR
ABOVE FINISHED FLOOR
BUILDING CONTROL SYSTEM
BUILDING
AFF
BCS
BLDG
COMMON (OR CLOSED)C
CUBIC FEET PER MINUTE (AIR FLOW RATE)
CEILING (OR COOLING)
CFM
CLG
EXISTING(E)
GENERAL CONTRACTORGC
MECHANICAL CONTRACTORMC
MANUFACTURER
NEW
MFG
(N)
NATIONAL ELECTRIC CODENEC
RETURN AIR
REQUIRED
RA
REQ'D
REQUIREMENTSREQ'MTS
SUPPLY AIRSA
TYPICALTYP
DIAMETERØ
COMBINATION FIRE/SMOKE DAMPERFSD
FD FIRE DAMPER
WITHW/
WITHOUTW/O
SWITCHS
DUPLEX RECEPTACLE
C - ABOVE COUNTER
- OCCUPANCY SENSOR/SWITCHO
TELEPHONE WALL OUTLET
DATA WALL OUTLET
COMBO VOICE/DATA OUTLET
X" - X" AFF HEIGHT
SHEET NO.
DRAWING TITLE
AVON | DENVER | FORT COLLINS
˛ ˛
ME0.1
GENERAL
MECHANICAL
INFORMATIONSTEADMAN CLINIC181 WEST MEADOW DRIVEVAIL, COCopyright VERTICAL ARTS, INC.
All Rights Reserved
This document, and the ideas and designs
incorporated herein, as an instrument of
professional service, is the property of Vertical
Arts Inc. and is not to be used, in whole or in part,
for any other project without the written
authorization from a principal of Vertical Arts, Inc.
ISSUE NAME DATE
PERMIT 11.17.2017
12/27/17