HomeMy WebLinkAboutB17-0483_[1] 9223.02M000-ME0.1_1514401253.pdf' ' ISSUE LOG KEY: # DATEISSUE LOG MECHANICAL SHEET INDEX TITLE GENERAL MECHANICAL INFORMATIONME0.1 PERMIT11.17.2017 ISSUED AS PART OF A SET ' ' NOT PART OF SET ' ' ISSUED FOR INFORMATION ONLY* √ √ √ MECHANICAL-ELECTRICAL PLANSME2.1 NOTES 1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONS ON LEGEND SHEET ARE NOT NECESSARILY USED ON THIS PROJECT. 2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES AND NOTATION CONVENTIONS OCCURRING IN THIS DRAWING SET ARE NECESSARILY DEFINED ON THESE LEGENDS. CONSULT THE ENGINEER IN THE EVENT SYMBOLOGY OR NOTATION INTERPRETATION IS REQUIRED. ABOVE SEA LEVEL PROJECT ALTITUDE 8,150' SPECIFICATIONS: 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK. 2. REVIEW ARCHITECTURAL, STRUCTURAL, MECHANICAL, AND OTHER DRAWINGS PRIOR TO BID. 3. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 4. SUBCONTRACTORS SHALL BE RESPONSIBLE TO NOTIFY THE PRIME CONTRACTOR OF DISCREPANCIES OR CONFLICTS IN THE CONSTRUCTION DOCUMENTS FOUND DURING BIDDING AND/OR PRIOR TO PERFORMING THE WORK. 5. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE OF COLORADO, AND NATIONAL CODES AND ORDINANCES. 6. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 7. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 8. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. 9. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. PROVIDE LABOR AND MATERIALS AS REQUIRED TO MAINTAIN AND/OR RESTORE CONTINUITY OF EXISTING SYSTEMS. 10. PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT. 11. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION. 12. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER. 13. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. FOR HID FIXTURES AND WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. 600 VOLT ALUMINUM WIRE AND CABLE IN SIZES 1/0 AND LARGER MAY BE SUBSTITUTED FOR COPPER ON SERVICES AND FEEDERS IF AMPACITY IS EQUAL TO OR GREATER THAN COPPER, AND VOLTAGE DROP IS EQUAL TO OR LESS THAN COPPER AND SHALL BE TERMINATED AT SWITCHES, LUGS, CIRCUIT BREAKERS, ETC., WITH MAC-ADAPT SERIES "MPT" MACHINE COMPRESSION ADAPTERS OR EQUAL. 14. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 15. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. 16. WIRE TERMINATION PROVISIONS FOR PANELBOARDS, CIRCUIT BREAKERS, SAFETY SWITCHES, AND ALL OTHER ELECTRICAL APPARATUS SHALL BE LISTED AS SUITABLE FOR 75 DEGREE CELSIUS. 17. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 15 AMPERES FOR DUPLEX RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT. 18. DEVICES SHALL BE AS FOLLOWS: A. RECEPTACLES - MATCH EXISTING OR HUBBELL NUMBER 5262 SERIES B. COVER PLATES SHALL EXISTING IN OTHER OFFICES OR AS SELECTED BY ARCHITECT. PROVIDE COVER PLATES FOR SWITCHES, RECEPTACLES, TELEPHONE, TELEVISION, COMPUTER, AND J-BOX OUTLETS AS REQUIRED. 19. FIXTURES RECESSED IN "T-BAR" CEILING SHALL BE SUPPORTED INDEPENDENTLY OF CEILING SYSTEM, WITH FOUR NUMBER 12 HANGER WIRES UP TO STRUCTURE. SECURE HANGER WIRES TO CORNERS OF FIXTURE. CLIP FIXTURE TO GRID ON TWO SIDES WITH FACTORY-FURNISHED CLIPS. FINAL CONNECTION TO FIXTURE SHALL BE MADE WITH A FLEXIBLE U.L. APPROVED ASSEMBLY. 20. ALL DUCTWORK, DIFFUSERS, PIPING, FIXTURES, AND EQUIPMENT SHOWN IN LIGHT LINE WEIGHT IS EXISTING, NEW INDICATED BY HEAVIER LINE WEIGHT, EXCEPT WHERE NOTED. PIPES, DUCTWORK, EQUIPMENT, ETC. TO BE REMOVED, ARE SHOWN HATCHED. 21. OFFSET PIPING, DUCTWORK, ETC. AS NECESSARY TO ACCOMMODATE STRUCTURE, BEAMS, AND COLUMNS, AND EXISTING EQUIPMENT. 22. FIRE STOPPING REQUIREMENT. PENETRATIONS THROUGH RATED WALLS AND FLOORS SHALL BE SEALED WITH A MATERIAL CAPABLE OF PREVENTING THE PASSAGE OF FLAMES AND HOT GASSES WHEN SUBJECTED TO THE REQUIREMENTS OF THE TEST STANDARD SPECIFIC FOR FIRE STOPS ASTM-E-814. ACCEPTABLE MATERIALS INCLUDE: DOW CORNING RTV FIRE STOP FOAM FOR BARE PIPE, METAL CONDUIT, AND ELECTRICAL CABLE; 3M FIRE DAM 150 CAULK FOR BARE PIPE, METAL CONDUIT, AND BUILDING CONSTRUCTION GAPS; 3M CP-25 CAULK AND FS-195 INTUMESCENT STRIPS FOR INSULATED PIPES, PLASTIC PIPE OR CONDUIT, AND ELECTRICAL CABLE. SUBMIT UL LISTED APPLICATION DATA FOR EACH TYPE OF PENETRATION ENCOUNTERED. 26. FIRE PROTECTION DESIGN/BUILD REQUIREMENTS: A. REVIEW AND REVISE EXISTING SPRINKLER SYSTEM. RELOCATE EXISTING OR ADD NEW SPRINKLER HEADS AS REQUIRED IN ACCORDANCE WITH NFPA 13, ALL APPLICABLE CODES AND ORDINANCES AND PROJECT REQUIREMENTS. B. SYSTEM SHALL BE INSTALLED COMPLETE AND OPERATIONAL, INCLUDING WATER FLOW INDICATOR, CONNECTIONS TO EXISTING ALARM, DRAIN PIPING, IDENTIFICATION SIGNS, ETC. C. WORK SHALL BE PERFORMED BY A QUALIFIED FIRE SPRINKLER INSTALLER WITH A MINIMUM OF FIVE (5) YEARS' EXPERIENCE IN SIMILAR INSTALLATIONS. D. COORDINATE ALL WORK WITH ALL OTHER TRADES PRIOR TO AND DURING INSTALLATION. TV OUTLET DIAGRAM NOTES: 1. PROVIDE LEVEL 1 ADMINISTRATION PER ANSI/TIA/EIA-606. 2. PROVIDE LABEL ON FRONT OF FACEPLATE. MODULAR CAT6 CONNECTOR (BLUE). TERMINATE T568B. F-CONNECTOR, FEMALE PASS-THROUGH. 2-PORT MODULAR COMMUNICATIONS FACEPLATE, COLOR TO MATCH RECEPTACLES. 4PR CAT6 UTP CABLE (BLUE JACKET). 1" C. SERIES 6 (RG6/U) CABLE (GREEN JACKET). NO SCALE OUTLET LABEL OUTLET LABEL DATA OUTLET DIAGRAM MODULAR CAT6 CONNECTOR (BLUE). TERMINATE T568B. BLANK MODULAR INSERT, MATCH FACEPLATE COLOR. 2-PORT MODULAR COMMUNICATIONS FACEPLATE, COLOR TO MATCH RECEPTACLES. 4PR CAT6 UTP CABLE (BLUE JACKET). NO SCALE OUTLET LABEL OUTLET LABEL NOTES: 1. PROVIDE LEVEL 1 ADMINISTRATION PER ANSI/TIA/EIA-606. 2. PROVIDE LABEL ON FRONT OF FACEPLATE. 1" C. NO SCALE TYPICAL DEVICE ALIGNMENT EQ EQ 6"MIN. ℄ ℄ ℄ DOOR WINDOW EQ EQ ℄LIGHTING CONTROL ℄ ℄ OFFSET COMMUNICATIONS DEVICES FROM POWER DEVICES TO EITHER OPPOSITE SIDE OF STUD BAY, OR ADJACENT STUD BAY. NOTES: 1. IF ALIGNMENT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. EQ BACKSPLASH ABOVE COUNTER DEVICE RECEPTACLE COUNTERTOP EQ FINISHED FLOOR FINISHED CEILING 6" MIN. 20" MAX. ALIGN DEVICES (OUTLETS, CONTROLS, ETC.) VERTICALLY. DO NOT VERTICALLY ALIGN POWER AND COMMUNICATIONS DEVICES SIMULTANEOUSLY. 18" 78" 48" ELECTRICAL DEVICES NOTES: 1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. NO SCALE TYPICAL DEVICE MOUNTING HEIGHTS S TOP OF CABINET TOP OF DEVICE CL OF DEVICE FINISHED FLOOR FINISHED CEILING PLAN SYMBOLS & ABBREVIATIONS THERMOSTATT TELEVISION OUTLET - WALL MOUNTEDTV VARIABLE VOLUME BOXVV VARIABLE VOLUME BOX W/ REHEATVR ABOVE FINISHED FLOOR BUILDING CONTROL SYSTEM BUILDING AFF BCS BLDG COMMON (OR CLOSED)C CUBIC FEET PER MINUTE (AIR FLOW RATE) CEILING (OR COOLING) CFM CLG EXISTING(E) GENERAL CONTRACTORGC MECHANICAL CONTRACTORMC MANUFACTURER NEW MFG (N) NATIONAL ELECTRIC CODENEC RETURN AIR REQUIRED RA REQ'D REQUIREMENTSREQ'MTS SUPPLY AIRSA TYPICALTYP DIAMETERØ COMBINATION FIRE/SMOKE DAMPERFSD FD FIRE DAMPER WITHW/ WITHOUTW/O SWITCHS DUPLEX RECEPTACLE C - ABOVE COUNTER - OCCUPANCY SENSOR/SWITCHO TELEPHONE WALL OUTLET DATA WALL OUTLET COMBO VOICE/DATA OUTLET X" - X" AFF HEIGHT SHEET NO. DRAWING TITLE AVON | DENVER | FORT COLLINS ˛ ˛ ME0.1 GENERAL MECHANICAL INFORMATIONSTEADMAN CLINIC181 WEST MEADOW DRIVEVAIL, COCopyright VERTICAL ARTS, INC. All Rights Reserved This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Vertical Arts Inc. and is not to be used, in whole or in part, for any other project without the written authorization from a principal of Vertical Arts, Inc. ISSUE NAME DATE PERMIT 11.17.2017 12/27/17