HomeMy WebLinkAboutB17-0483_A0.1 - GENERAL INFORMATION_1514401252.pdfABBREVIATIONS
SYMBOLS
&
A
A/C
AB
ABV
ACP
ACT
AD
ADMIN
ADJ
A.F.F.
ALT
ALUM
AP
APPROX
ARCH
AIR CONDITIONING
ANCHOR BOLT
ABOVE
ACOUSTICAL PANEL
ACOUSTICAL CEILING TILE
AREA DRAIN
ADMINISTRATION
ADJACENT
ABOVE FINISH FLOOR
ALTERNATE
ALUMINUM
ACCESS PANEL
APPROXIMATE
ARCHITECT/ARCHITECTURE
B
BD
BLDG
BLK
BLW
BM
B.O.
BR
BOARD
BUILDING
BLOCK
BELOW
BEAM
BOTTOM OF
BRONZE
C
C
CABT
CLNG
CI
CJ
CLR
CMU
CO
COL
CONT
CONC
CONV
CPT
CT
CU
CASEMENT
CABINET
CEILING
CAST IRON
CONTROL JOINT
CLEAR
CONCRETE MASONRY UNIT
CLEANOUT
COLUMN
CONTINUOUS
CONCRETE
CONVECTOR
CARPET
CERAMIC TILE
CONDENSING UNITD
DTL
D.F.
DH
DIA
DIM
DO
DR
DW
DWG
DETAIL
DRINKING FOUNTAIN
DOUBLE HUNG
DIAMETER
DIMENSION
DOUBLE WALL OVENS
DOOR DRAWING
DISHWASHER
DRAWING
E
EA
EF
ELEV
ELEC
ENCL
ENT
EQ
EQPT
EXST
EACH
EXHAUST FAN
ELEVATION
ELECTRIC
ENCLOSURE
ENTRANCE
EQUAL
EQUIPMENT
EXISTING
F
FD
FDN
FE
FIN
FLR
F.O.W
F.R.S.C.
FR
FS
FTG
FLOOR DRAIN
FOUNDATION
FIRE EXTENGUISHER
FINISH
FLOOR
FACE OF WALL (STUD, ETC.)
FIRE RESISTANT SELF CLOSING
FRAME
FLOOR SINK
FOOTING
AND
ANGLE
CENTER LINE
G
GA
GALV
GC
GL
GWB
GAUGE
GALVANIZED
GENERAL CONTRACTOR
GLASS/GLAZING
GYPSUM WALL BOARD
H
HB
HDCP
HGT
HM
H.P.
HR
H&V
HVAC
HOSE BIBB
HANDICAPPED
HEIGHT
HOLLOW METAL
HIGH POINT
HOUR
HEATING & VENTILATION
HEATING, VENTILATION & AIR
CONDITIONINGI
I.D.
INFO
INSUL
INSIDE DIAMETER
INFORMATION
INSULATION
J
JC
JT
JANITOR CLOSET
JOINT
K
KPL
KIT
KB
KC
KO
KICKPLATE
KITCHEN
KNEE BRACE
KITCHEN CABINET
KNOCKOUT
L
L.P.
LT
LOW POINT
LIGHT
M
MTL
MAT
MAX
MECH
MIN
M.O.
MTD
METAL
MATERIAL
MAXIMUM
MECHANICAL
MINIMUM
MASONRY OPENING
MOUNTED
N
NEC
N.I.C.
NO
N.T.S.
NECESSARY
NOT IN CONTRACT
NUMBER
NOT TO SCALE
O
O.C.
O.D.
O.H.
OPNG
OPP
ON CENTER
OUTSIDE DIAMETER
OPPOSITE HAND
OPENING
OPPOSITE
P
PART
P&D
PL
PLAM
PLMB
PLYWD
PR
PT
PTD
PARTITION
PLUMBING & DRAINAGE
PROPERTY LINE
PLASTIC LAMINATE
PLUMBING
PLYWOOD
PAIR
PAINT
PAINTED
R
R
RAD
RCP
R.D.
REC
REFL
REQ
REV
RM
R.O.
RADIUS/RISER
RADIATOR
REFLECTED CEILING PLAN
ROOF DRAIN
RECESS
REFLECTED
REQUIRED
REVEAL
ROOM
ROUGH OPENING
S
S
SAD
SF
SHT
SIM
SLNT
SPEC'D
SPEC
S.O.G.
STD
STL
SS
STOR
STF
SINK
SADDLE
SQUARE FEET
SHEET
SIMILAR
SEALANT
SPECIFIED
SPECIFICATION
SLAB ON GRADE
STANDARD
STEEL
STAINLESS STEEL
STORAGE
STAFFT
T
T.B.S.
T.O.D.
THK
TEL
T.O.
T.O.D.
T.O.S.
T.O.W.
TYP
TREAD
TO BE SELECTED
TOP OF DRAIN
THICK
TELEPHONE
TOP OF
TOP OF DECKING
TOP OF SLAB
TOP OF WALL
TYPICAL
U
U.N.O.
UNF
U.V.
UNLESS NOTED OTHERWISE
UNFINISHED
UNIT VENTILATION
V
V
VCT
VENT.
V.I.F.
VP
VARIES
VINYL COMPOSITE TILE
VENTILATOR
VERIFY IN FIELD
VENT PIPE
W
W
W/
W/O
WC
W/D
WD
WH
W.P.
WT
WASHER
WITH
WITHOUT
WATER CLOSET
WASHER.DRYER
WOOD
WATER HEATER
WATERPROOF/WATERPROOFING
WEIGHT
1. ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND IN ACCORDANCE WITH ALL APPLICABLE
CODES, ORDINANCES, LAWS, PERMITS AND THE CONTRACT DOCUMENTS.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION ON
THE SITE. ALL MATERIALS AND COMPONENTS SHALL BE INSTALLED PER MANUFACTURES INSTRUCTIONS AND
SPECIFICATIONS WITH FULL WARRANTIES.
3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING WORK. SHOULD
A DISCREPANCY APPEAR IN THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND
EXISTING CONDITIONS, NOTIFY THE ARCHITECT AT ONCE FOR INSTRUCTION ON HOW TO PROCEED.
4. CHANGES FROM THE PLANS MADE WITHOUT CONSENT OF THE ARCHITECT ARE UNAUTHORIZED AND SHALL
RELIEVE THE ARCHITECT OF RESPONSIBILITY FOR ALL CONSEQUENCES ARRIVING OUT OF SUCH CHANGES.
5. SHOULD A CONFLICT OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS, THE SPECIFICATIONS SHALL
TAKE PRECEDENCE UNLESS A WRITTEN DECISION FROM THE ARCHITECT HAS BEEN OBTAINED WHICH
DESCRIBES A CLARIFICATION OR ALTERNATE METHOD AND/OR MATERIALS.
6. THE CONTRACTOR SHALL CONFINE HIS/HER OPERATIONS ON THE SITE TO AREAS PERMITTED BY THE OWNER.
7. THE JOB SITE SHALL BE MAINTAINED IN A CLEAN, ORDERLY CONDITION, FREE OF DEBRIS AND LITTER AND
SHALL NOT BE UNREASONABLY ENCUMBERED WITH ANY MATERIALS OR EQUIPMENT. EACH SUB-CONTRACTOR
IMMEDIATELY UPON COMPLETION OF EACH PHASE OF HIS/HER WORK SHALL REMOVE ALL TRASH AND DEBRIS AS
OF RESULT OF HIS/HER OPERATION.
8. ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED AND PROTECTED TO PREVENT DAMAGE
AND DETERIORATION. FAILURE TO PROTECT MATERIALS MAY BE CAUSE FOR REJECTION OF WORK.
9. THE CONTRACTOR SHALL DO ALL CUTTING, FITTING OR PATCHING OF HIS/HER WORK THAT MAY BE REQUIRED
TO MAKE ITS SEVERAL PARTS FIT TOGETHER PROPERLY AND SHALL NOT ENDANGER ANY OTHER WORK BY
CUTTING, EXCAVATING OR OTHERWISE ALTERING THE TOTAL WORK OR ANY OTHER PART OF IT. ALL PATCHING,
REPAIRING AND REPLACING OF MATERIALS AND SURFACES CUT OR DAMAGED IN EXECUTION OF WORK SHALL BE
DONE WITH APPLICABLE MATERIALS SO THAT SURFACES REPLACED WILL, UPON COMPLETION, MATCH
SURROUNDING SIMILAR SURFACES.
10. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE COMMENCED
UNTIL THE SUBMISSION HAS BEEN REVIEWED BY THE ARCHITECT. ALL SUCH PORTIONS OF THE WORK SHALL BE
IN ACCORDANCE WITH REVIEWED SHOP DRAWINGS AND SAMPLES.
11. DIMENSIONS:
A) ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE OF DRAWINGS.
B) ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF C.M.U. OR FACE OF CONCRETE U.N.O.
C) CEILING HEIGHT DIMENSIONS ARE FROM FINISHED FLOOR TO FACE OF FINISH CEILING MATERIALS
UNLESS NOTED OTHERWISE.
12. CONTRACTOR TO PROVIDE ALL NECESSARY BLOCKING, BACKING AND FRAMING FOR LIGHT FIXTURES,
ELECTRICAL UNITS, A.C. EQUIPMENT, RECESSED ITEMS AND ALL OTHER ITEMS AS REQUIRED.
13. WHERE LARGER STUDS OR FURRING ARE REQUIRED TO COVER PIPING AND CONDUITS, THE LARGER STUD
SIZE OR FURRING SHALL BE EXTENDED THE FULL SURFACE OF THE WALL WIDTH AND LENGTH WHERE THE
FURRING OCCURS.
14. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL CONCEALED SPACES, VOIDS,
ATTICS, ETC. VERIFY TYPE REQUIRED WITH ARCHITECT PRIOR TO INSTALLATION.
15. PROVIDE ACCESS AND MINIMUM VENTILATION REQUIREMENTS TO ALL CRAWL SPACES AS REQUIRED BY
GOVERNING CODES.
16. INSTALL TEMPERED GLASS AS REQUIRED BY GOVERNING CODES.
17. STRUCTURAL AND FIRE RESISTIVE INTEGRITY SHALL BE MAINTAINED AS REQUIRED BY GOVERNING CODES.
18. FIREBLOCKS AND DRAFT STOPS SHALL BE PROVIDED AS REQUIRED BY GOVERNING CODES.
19. THE BUILDING THERMAL ENVELOPE SHALL BE DURABLY SEALED TO LIMIT AIR INFILTRATION PER I.E.C.C. 402.4
20. RECESSED LIGHT SHALL BE SEALED PER I.E.C.C. 402.4.3.
GENERAL NOTES:
1. CONTRACTOR SHALL COORDINATE ALL DEMOLITION WITH THE NEW CONSTRUCTION TO DETERMINE
DIMENSIONS AND SCOPE OF WORK AND TO ENSURE THAT NO ITEMS OR SERVICES TO REMAIN ARE DISTURBED
OR DAMAGED.
2. PROVIDE AND PLACE BRACING AND SHORING AS REQUIRED. TAKE NECESSARY PRECAUTIONS TO PROPERLY
INSTALL TEMPORARY SUPPORT STRUCTURES TO REMAIN TO PREVENT DAMAGE OR UNACCEPTABLE
DEFLECTION.
3. WHERE REMOVALS ARE MADE CONTRACTOR SHALL PATCH ALL CONSTRUCTION TO PROVIDE SMOOTH AS
NEW CONDITION.
3. CONTRACTOR SHALL PATCH AND/OR LEVEL ALL EXISTING SURFACES RECEIVING NEW FINISHES.
4. PROTECT ALL ITEMS TO REMAIN AND ALL EXISTING CONSTRUCTION NOT SCHEDULED TO BE DEMOLISHED -
IMMEDIATELY REPAIR OR REPLACE DAMAGED ITEMS.
5. REROUTE ALL UTILITIES REMAINING IN USE INTERRUPTED BY DEMOLITION.
6. OWNER TO REMOVE ALL FURNITURE, EQUIPMENT, AND OTHER FURNISHINGS FROM CONSTRUCTION AREA
PRIOR TO PROJECT START.
7. CONTRACTOR TO COORDINATE DEMOLITION WITH ENGINEERING DOCUMENTS.
8. SEAL ALL OPENINGS UNCOVERED DURING DEMOLITION OF FURRED WALLS, RELOCATION OF DUCT SHAFTS
OR PIPE CHASES, OR REMOVAL OF PARTITIONS OR FIXTURES.
9. ALL DAMAGED EXISTING WORK MUST BE REPAIRED AND PREPARED TO RECEIVE NEW FINISHES. THE
CONTRACTOR SHALL INCLUDE ON THE BASE PRICE ALL REPAIR OR REPLACEMENT WORK REQUIRED FOR NEW
CONSTRUCTION.
10. RESTORE THE INTEGRITY OF EXISTING FIRE RATED PARTITIONS, FIREPROOFING AND STRUCTURE DAMAGED
DURING DEMOLITION. GC TO FIRE STOP RATED PENETRATIONS AT THE END OF EACH DAY.
11. DUST PROOF PARTITIONS & RELATED PROTECTIONS ERECTED DURING DEMOLITION OPERATIONS SHALL
REMAIN IN PLACE FOR THE DURATION OF THE CONSTRUCTION PERIOD UNLESS OTHERWISE INSTRUCTED BY
THE TENANT OR ARCHITECT.
12. VERIFY ALL EXISTING POWER/DATA/GAS DEVICES; REMOVE ALL DEAD AND NON-STANDARD DEVICES
13. REMOVE EXISTING CEILING TILES; MAINTAIN GRID IN ALL AREAS WHERE CEILING IS SHOWN TO REMAIN.
REMOVE AND REPLACE ANY DEFECTIVE PORTIONS OF GRID AND PREPARE FOR NEW CEILING TILES
GENERAL DEMOLITION NOTES:
VICINITY MAP
NORTHPROJECT LOCATION
WEST WING - VAIL HEALTH
1
A4.1
A6.0
1 SIM
DOOR TAG
WINDOW TAG
FLOOR OR
SPOT ELEVATION
REVISION SYMBOL
INTERIOR ELEVATION
SYMBOL
DETAIL NO.
SHEET NO.
SECTION NO.
SHEET NO.
PROPOSED
CONTOUR
EXISTING
CONTOUR
DRAWING SYMBOLS
100
1
24
3
A8.1
100'-0"
T.O. PLYWOOD
100
WALL TAG1
114
CRPT CRPT FLOOR FINISH
GRAPHIC KEY TO MATERIALS
BATT
BRICK
STONE
STEEL
RIGID
FINISH
ROUGH
BLOCKING
GLU-LAM
PLYWOOD
EARTH
CONCRETE
MASONRY
METAL
INSULATION
WOOD
GROUT LIGHWEIGHT
CONCRETE
CONCRETE BLOCK
COMPACTED FILL
POROUS FILL
CAST
CODE ANALYSIS
2015 INTERNATIONAL BUILDING CODE
2015 INTERNATIONAL FIRE CODE
2015 INTERNATIONAL MECHANICAL CODE
2015 INTERNATIONAL PLUMBING CODE
2012 FUEL AND GAS CODE
2015 INTERNATIONAL ENERGY CONSERVATION CODE
2014 NATIONAL ELECTRICAL CODE
2015 INTERNATIONAL EXISTING BUILDING CODE
TOWN OF VAIL AMENDMENTS
OCCUPANCY
- LEVEL 3 HEALTH CARE (I-2)
-LEVEL 4 BUSINESS (B)
TYPE OF CONSTRUCTION (IBC TABLE 601 AND NFPA 220)
- TYPE I-B, II (222)
- FLOOR-CEILING 2 HOUR
- ROOF-CEILING 1 HOUR
- STRUCTURAL FRAME 2 HOUR - 1 HOUR WHERE SUPPORTS ROOF
- COLUMNS 2 HOUR - 1 HOUR WHERE SUPPORTS ROOF
- LOAD-BEARING WALLS
EXTERIOR 2 HOUR - 1 HOUR WHERE SUPPORTS ROOF
INTERIOR 2 HOUR - 1 HOUR WHERE SUPPORTS ROOF
BUILDING IS FULLY SPRINKLED
PROJECT DESCRIPTION
PROJECT CONSISTS OF CREATING A NEW OFFICE FROM AND EXISTING
BUSINESS CENTER. TWO WALLS AND A DOOR WILL BE ADDED TO CREATE
THE SPACE.
OWNER
STEADMAN CLINIC
181 WEST MEADOW DRIVE
VAIL, CO 81657
PROJECT TEAM
970.476.1100
ARCHITECT
VERTICAL ARTS, INC.
216 MAIN STREET
UNIT C-210
EDWARDS, CO 81632
CONTACT: CHANDLER DEIMUND
970.594.0056
CONTRACTOR
JACKSON BUILDING COMPANY
PO BOX 6625
VAIL, CO 81658
CONTACT: BRICE JACKSON
970.331.6800
MEP ENGINEER
BG BUILDINGWORKS
222 CHAPEL PLACE
UNIT AC-21
AVON, CO 81620
CONTACT: DAVID LYLE
970.949.6108
Copyright VERTICAL ARTS, INC.
All Rights Reserved
This document, and the ideas and designs
incorporated herein, as an instrument of
professional service, is the property of Vertical
Arts Inc. and is not to be used, in whole or in part,
for any other project without the written
authorization from a principal of Vertical Arts, Inc.
SHEET NO.
DRAWING TITLE
ISSUE NAME DATE
12/11/2017 11:09:23 AMA0.1
GENERAL
INFORMATION
STEADMAN CLINIC181 WEST MEADOW DRIVEVAIL, COSHEET INDEX
Sheet
Number Sheet Name
ARCHITECTURAL
A2.1 PLANS AND ELEVATIONS
GENERAL
A0.1 GENERAL INFORMATION
MECHANICAL
ME0.1 GENERAL MECHANICAL INFORMATION
ME2.1 MECHANICAL - ELECTRICAL PLANS
PERMIT SET 11.18.2017
11/17/2017
12/27/17