Loading...
HomeMy WebLinkAboutB17-0483_A0.1 - GENERAL INFORMATION_1514401252.pdfABBREVIATIONS SYMBOLS & A A/C AB ABV ACP ACT AD ADMIN ADJ A.F.F. ALT ALUM AP APPROX ARCH AIR CONDITIONING ANCHOR BOLT ABOVE ACOUSTICAL PANEL ACOUSTICAL CEILING TILE AREA DRAIN ADMINISTRATION ADJACENT ABOVE FINISH FLOOR ALTERNATE ALUMINUM ACCESS PANEL APPROXIMATE ARCHITECT/ARCHITECTURE B BD BLDG BLK BLW BM B.O. BR BOARD BUILDING BLOCK BELOW BEAM BOTTOM OF BRONZE C C CABT CLNG CI CJ CLR CMU CO COL CONT CONC CONV CPT CT CU CASEMENT CABINET CEILING CAST IRON CONTROL JOINT CLEAR CONCRETE MASONRY UNIT CLEANOUT COLUMN CONTINUOUS CONCRETE CONVECTOR CARPET CERAMIC TILE CONDENSING UNITD DTL D.F. DH DIA DIM DO DR DW DWG DETAIL DRINKING FOUNTAIN DOUBLE HUNG DIAMETER DIMENSION DOUBLE WALL OVENS DOOR DRAWING DISHWASHER DRAWING E EA EF ELEV ELEC ENCL ENT EQ EQPT EXST EACH EXHAUST FAN ELEVATION ELECTRIC ENCLOSURE ENTRANCE EQUAL EQUIPMENT EXISTING F FD FDN FE FIN FLR F.O.W F.R.S.C. FR FS FTG FLOOR DRAIN FOUNDATION FIRE EXTENGUISHER FINISH FLOOR FACE OF WALL (STUD, ETC.) FIRE RESISTANT SELF CLOSING FRAME FLOOR SINK FOOTING AND ANGLE CENTER LINE G GA GALV GC GL GWB GAUGE GALVANIZED GENERAL CONTRACTOR GLASS/GLAZING GYPSUM WALL BOARD H HB HDCP HGT HM H.P. HR H&V HVAC HOSE BIBB HANDICAPPED HEIGHT HOLLOW METAL HIGH POINT HOUR HEATING & VENTILATION HEATING, VENTILATION & AIR CONDITIONINGI I.D. INFO INSUL INSIDE DIAMETER INFORMATION INSULATION J JC JT JANITOR CLOSET JOINT K KPL KIT KB KC KO KICKPLATE KITCHEN KNEE BRACE KITCHEN CABINET KNOCKOUT L L.P. LT LOW POINT LIGHT M MTL MAT MAX MECH MIN M.O. MTD METAL MATERIAL MAXIMUM MECHANICAL MINIMUM MASONRY OPENING MOUNTED N NEC N.I.C. NO N.T.S. NECESSARY NOT IN CONTRACT NUMBER NOT TO SCALE O O.C. O.D. O.H. OPNG OPP ON CENTER OUTSIDE DIAMETER OPPOSITE HAND OPENING OPPOSITE P PART P&D PL PLAM PLMB PLYWD PR PT PTD PARTITION PLUMBING & DRAINAGE PROPERTY LINE PLASTIC LAMINATE PLUMBING PLYWOOD PAIR PAINT PAINTED R R RAD RCP R.D. REC REFL REQ REV RM R.O. RADIUS/RISER RADIATOR REFLECTED CEILING PLAN ROOF DRAIN RECESS REFLECTED REQUIRED REVEAL ROOM ROUGH OPENING S S SAD SF SHT SIM SLNT SPEC'D SPEC S.O.G. STD STL SS STOR STF SINK SADDLE SQUARE FEET SHEET SIMILAR SEALANT SPECIFIED SPECIFICATION SLAB ON GRADE STANDARD STEEL STAINLESS STEEL STORAGE STAFFT T T.B.S. T.O.D. THK TEL T.O. T.O.D. T.O.S. T.O.W. TYP TREAD TO BE SELECTED TOP OF DRAIN THICK TELEPHONE TOP OF TOP OF DECKING TOP OF SLAB TOP OF WALL TYPICAL U U.N.O. UNF U.V. UNLESS NOTED OTHERWISE UNFINISHED UNIT VENTILATION V V VCT VENT. V.I.F. VP VARIES VINYL COMPOSITE TILE VENTILATOR VERIFY IN FIELD VENT PIPE W W W/ W/O WC W/D WD WH W.P. WT WASHER WITH WITHOUT WATER CLOSET WASHER.DRYER WOOD WATER HEATER WATERPROOF/WATERPROOFING WEIGHT 1. ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND IN ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, LAWS, PERMITS AND THE CONTRACT DOCUMENTS. 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION ON THE SITE. ALL MATERIALS AND COMPONENTS SHALL BE INSTALLED PER MANUFACTURES INSTRUCTIONS AND SPECIFICATIONS WITH FULL WARRANTIES. 3. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SITE CONDITIONS BEFORE STARTING WORK. SHOULD A DISCREPANCY APPEAR IN THE CONTRACT DOCUMENTS, OR BETWEEN THE CONTRACT DOCUMENTS AND EXISTING CONDITIONS, NOTIFY THE ARCHITECT AT ONCE FOR INSTRUCTION ON HOW TO PROCEED. 4. CHANGES FROM THE PLANS MADE WITHOUT CONSENT OF THE ARCHITECT ARE UNAUTHORIZED AND SHALL RELIEVE THE ARCHITECT OF RESPONSIBILITY FOR ALL CONSEQUENCES ARRIVING OUT OF SUCH CHANGES. 5. SHOULD A CONFLICT OCCUR IN OR BETWEEN DRAWINGS AND SPECIFICATIONS, THE SPECIFICATIONS SHALL TAKE PRECEDENCE UNLESS A WRITTEN DECISION FROM THE ARCHITECT HAS BEEN OBTAINED WHICH DESCRIBES A CLARIFICATION OR ALTERNATE METHOD AND/OR MATERIALS. 6. THE CONTRACTOR SHALL CONFINE HIS/HER OPERATIONS ON THE SITE TO AREAS PERMITTED BY THE OWNER. 7. THE JOB SITE SHALL BE MAINTAINED IN A CLEAN, ORDERLY CONDITION, FREE OF DEBRIS AND LITTER AND SHALL NOT BE UNREASONABLY ENCUMBERED WITH ANY MATERIALS OR EQUIPMENT. EACH SUB-CONTRACTOR IMMEDIATELY UPON COMPLETION OF EACH PHASE OF HIS/HER WORK SHALL REMOVE ALL TRASH AND DEBRIS AS OF RESULT OF HIS/HER OPERATION. 8. ALL MATERIALS STORED ON THE SITE SHALL BE PROPERLY STACKED AND PROTECTED TO PREVENT DAMAGE AND DETERIORATION. FAILURE TO PROTECT MATERIALS MAY BE CAUSE FOR REJECTION OF WORK. 9. THE CONTRACTOR SHALL DO ALL CUTTING, FITTING OR PATCHING OF HIS/HER WORK THAT MAY BE REQUIRED TO MAKE ITS SEVERAL PARTS FIT TOGETHER PROPERLY AND SHALL NOT ENDANGER ANY OTHER WORK BY CUTTING, EXCAVATING OR OTHERWISE ALTERING THE TOTAL WORK OR ANY OTHER PART OF IT. ALL PATCHING, REPAIRING AND REPLACING OF MATERIALS AND SURFACES CUT OR DAMAGED IN EXECUTION OF WORK SHALL BE DONE WITH APPLICABLE MATERIALS SO THAT SURFACES REPLACED WILL, UPON COMPLETION, MATCH SURROUNDING SIMILAR SURFACES. 10. NO PORTION OF THE WORK REQUIRING A SHOP DRAWING OR SAMPLE SUBMISSION SHALL BE COMMENCED UNTIL THE SUBMISSION HAS BEEN REVIEWED BY THE ARCHITECT. ALL SUCH PORTIONS OF THE WORK SHALL BE IN ACCORDANCE WITH REVIEWED SHOP DRAWINGS AND SAMPLES. 11. DIMENSIONS: A) ALL DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE OF DRAWINGS. B) ALL DIMENSIONS ARE TO FACE OF STUD, FACE OF C.M.U. OR FACE OF CONCRETE U.N.O. C) CEILING HEIGHT DIMENSIONS ARE FROM FINISHED FLOOR TO FACE OF FINISH CEILING MATERIALS UNLESS NOTED OTHERWISE. 12. CONTRACTOR TO PROVIDE ALL NECESSARY BLOCKING, BACKING AND FRAMING FOR LIGHT FIXTURES, ELECTRICAL UNITS, A.C. EQUIPMENT, RECESSED ITEMS AND ALL OTHER ITEMS AS REQUIRED. 13. WHERE LARGER STUDS OR FURRING ARE REQUIRED TO COVER PIPING AND CONDUITS, THE LARGER STUD SIZE OR FURRING SHALL BE EXTENDED THE FULL SURFACE OF THE WALL WIDTH AND LENGTH WHERE THE FURRING OCCURS. 14. PROVIDE ALL ACCESS PANELS AS REQUIRED BY GOVERNING CODES TO ALL CONCEALED SPACES, VOIDS, ATTICS, ETC. VERIFY TYPE REQUIRED WITH ARCHITECT PRIOR TO INSTALLATION. 15. PROVIDE ACCESS AND MINIMUM VENTILATION REQUIREMENTS TO ALL CRAWL SPACES AS REQUIRED BY GOVERNING CODES. 16. INSTALL TEMPERED GLASS AS REQUIRED BY GOVERNING CODES. 17. STRUCTURAL AND FIRE RESISTIVE INTEGRITY SHALL BE MAINTAINED AS REQUIRED BY GOVERNING CODES. 18. FIREBLOCKS AND DRAFT STOPS SHALL BE PROVIDED AS REQUIRED BY GOVERNING CODES. 19. THE BUILDING THERMAL ENVELOPE SHALL BE DURABLY SEALED TO LIMIT AIR INFILTRATION PER I.E.C.C. 402.4 20. RECESSED LIGHT SHALL BE SEALED PER I.E.C.C. 402.4.3. GENERAL NOTES: 1. CONTRACTOR SHALL COORDINATE ALL DEMOLITION WITH THE NEW CONSTRUCTION TO DETERMINE DIMENSIONS AND SCOPE OF WORK AND TO ENSURE THAT NO ITEMS OR SERVICES TO REMAIN ARE DISTURBED OR DAMAGED. 2. PROVIDE AND PLACE BRACING AND SHORING AS REQUIRED. TAKE NECESSARY PRECAUTIONS TO PROPERLY INSTALL TEMPORARY SUPPORT STRUCTURES TO REMAIN TO PREVENT DAMAGE OR UNACCEPTABLE DEFLECTION. 3. WHERE REMOVALS ARE MADE CONTRACTOR SHALL PATCH ALL CONSTRUCTION TO PROVIDE SMOOTH AS NEW CONDITION. 3. CONTRACTOR SHALL PATCH AND/OR LEVEL ALL EXISTING SURFACES RECEIVING NEW FINISHES. 4. PROTECT ALL ITEMS TO REMAIN AND ALL EXISTING CONSTRUCTION NOT SCHEDULED TO BE DEMOLISHED - IMMEDIATELY REPAIR OR REPLACE DAMAGED ITEMS. 5. REROUTE ALL UTILITIES REMAINING IN USE INTERRUPTED BY DEMOLITION. 6. OWNER TO REMOVE ALL FURNITURE, EQUIPMENT, AND OTHER FURNISHINGS FROM CONSTRUCTION AREA PRIOR TO PROJECT START. 7. CONTRACTOR TO COORDINATE DEMOLITION WITH ENGINEERING DOCUMENTS. 8. SEAL ALL OPENINGS UNCOVERED DURING DEMOLITION OF FURRED WALLS, RELOCATION OF DUCT SHAFTS OR PIPE CHASES, OR REMOVAL OF PARTITIONS OR FIXTURES. 9. ALL DAMAGED EXISTING WORK MUST BE REPAIRED AND PREPARED TO RECEIVE NEW FINISHES. THE CONTRACTOR SHALL INCLUDE ON THE BASE PRICE ALL REPAIR OR REPLACEMENT WORK REQUIRED FOR NEW CONSTRUCTION. 10. RESTORE THE INTEGRITY OF EXISTING FIRE RATED PARTITIONS, FIREPROOFING AND STRUCTURE DAMAGED DURING DEMOLITION. GC TO FIRE STOP RATED PENETRATIONS AT THE END OF EACH DAY. 11. DUST PROOF PARTITIONS & RELATED PROTECTIONS ERECTED DURING DEMOLITION OPERATIONS SHALL REMAIN IN PLACE FOR THE DURATION OF THE CONSTRUCTION PERIOD UNLESS OTHERWISE INSTRUCTED BY THE TENANT OR ARCHITECT. 12. VERIFY ALL EXISTING POWER/DATA/GAS DEVICES; REMOVE ALL DEAD AND NON-STANDARD DEVICES 13. REMOVE EXISTING CEILING TILES; MAINTAIN GRID IN ALL AREAS WHERE CEILING IS SHOWN TO REMAIN. REMOVE AND REPLACE ANY DEFECTIVE PORTIONS OF GRID AND PREPARE FOR NEW CEILING TILES GENERAL DEMOLITION NOTES: VICINITY MAP NORTHPROJECT LOCATION WEST WING - VAIL HEALTH 1 A4.1 A6.0 1 SIM DOOR TAG WINDOW TAG FLOOR OR SPOT ELEVATION REVISION SYMBOL INTERIOR ELEVATION SYMBOL DETAIL NO. SHEET NO. SECTION NO. SHEET NO. PROPOSED CONTOUR EXISTING CONTOUR DRAWING SYMBOLS 100 1 24 3 A8.1 100'-0" T.O. PLYWOOD 100 WALL TAG1 114 CRPT CRPT FLOOR FINISH GRAPHIC KEY TO MATERIALS BATT BRICK STONE STEEL RIGID FINISH ROUGH BLOCKING GLU-LAM PLYWOOD EARTH CONCRETE MASONRY METAL INSULATION WOOD GROUT LIGHWEIGHT CONCRETE CONCRETE BLOCK COMPACTED FILL POROUS FILL CAST CODE ANALYSIS 2015 INTERNATIONAL BUILDING CODE 2015 INTERNATIONAL FIRE CODE 2015 INTERNATIONAL MECHANICAL CODE 2015 INTERNATIONAL PLUMBING CODE 2012 FUEL AND GAS CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE 2014 NATIONAL ELECTRICAL CODE 2015 INTERNATIONAL EXISTING BUILDING CODE TOWN OF VAIL AMENDMENTS OCCUPANCY - LEVEL 3 HEALTH CARE (I-2) -LEVEL 4 BUSINESS (B) TYPE OF CONSTRUCTION (IBC TABLE 601 AND NFPA 220) - TYPE I-B, II (222) - FLOOR-CEILING 2 HOUR - ROOF-CEILING 1 HOUR - STRUCTURAL FRAME 2 HOUR - 1 HOUR WHERE SUPPORTS ROOF - COLUMNS 2 HOUR - 1 HOUR WHERE SUPPORTS ROOF - LOAD-BEARING WALLS EXTERIOR 2 HOUR - 1 HOUR WHERE SUPPORTS ROOF INTERIOR 2 HOUR - 1 HOUR WHERE SUPPORTS ROOF BUILDING IS FULLY SPRINKLED PROJECT DESCRIPTION PROJECT CONSISTS OF CREATING A NEW OFFICE FROM AND EXISTING BUSINESS CENTER. TWO WALLS AND A DOOR WILL BE ADDED TO CREATE THE SPACE. OWNER STEADMAN CLINIC 181 WEST MEADOW DRIVE VAIL, CO 81657 PROJECT TEAM 970.476.1100 ARCHITECT VERTICAL ARTS, INC. 216 MAIN STREET UNIT C-210 EDWARDS, CO 81632 CONTACT: CHANDLER DEIMUND 970.594.0056 CONTRACTOR JACKSON BUILDING COMPANY PO BOX 6625 VAIL, CO 81658 CONTACT: BRICE JACKSON 970.331.6800 MEP ENGINEER BG BUILDINGWORKS 222 CHAPEL PLACE UNIT AC-21 AVON, CO 81620 CONTACT: DAVID LYLE 970.949.6108 Copyright VERTICAL ARTS, INC. All Rights Reserved This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Vertical Arts Inc. and is not to be used, in whole or in part, for any other project without the written authorization from a principal of Vertical Arts, Inc. SHEET NO. DRAWING TITLE ISSUE NAME DATE 12/11/2017 11:09:23 AMA0.1 GENERAL INFORMATION STEADMAN CLINIC181 WEST MEADOW DRIVEVAIL, COSHEET INDEX Sheet Number Sheet Name ARCHITECTURAL A2.1 PLANS AND ELEVATIONS GENERAL A0.1 GENERAL INFORMATION MECHANICAL ME0.1 GENERAL MECHANICAL INFORMATION ME2.1 MECHANICAL - ELECTRICAL PLANS PERMIT SET 11.18.2017 11/17/2017 12/27/17