Loading...
HomeMy WebLinkAboutF18-0063_Approved Documents_1537305173.pdf 75 South Frontage Road Fire-Construction Permit 0West, TOWN OF VAIL F18-0063 Vail,CO 81657 Issued: 09/18/2018 TOWN OF VAIL „ Office:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 1330 SANDSTONEDR 9(2103121230049)(210312123004 ) Unit#:9 P a r c e IN u tuber: 210312123004 LegalDescription: Subdivision:OVERLOOKATVAILUNIT9 BK-0683 PG-0811 MAP 12-15-95 BK-0684 PG-0700 DEC 12- 28-9 5 Contacts ContactType: Applicant Full Name: Don Anderson Address: PO Box 3940331 MetcalfRd Avon,CO 81620 Phone: 9707488888 ContactType: PropertyOwner Full Name: BOUCHER,PETERW.&CAROLINE C. Address: Phone: None Contractor Contractor Type: Fire Protection Company: Meridian Intermountain/Vail Electronics State License#: Phone: 970-748-8888 Projecllnformation ProjeciName: BoucherResidence2018 ProjectDescription: Boucherresidence.Relocate three sprinklerheads. Fees Paid Account#:001-0000.31111.00 -Fire Scope LetterFee FeeAmount: $216.00 TotalPaid: $216.00 Conditions Issued By:TownofV ailFireand EmergencyServices Department NOTICE:Byissuance ofthis Permittheapplicantagreesto complyto all Titlesof theTownof Vail Code and all applicableStateand Federal law.Failureto do so will void this Permitand the applicantshallforfeitall applicablefees. °I1111 PERMIT FEE RECEIPT TOWN OF VAIL Case # F 18-0063 Date Printed: 09/11/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: F18-0063 Status: Created Permit Number: Date Started: 09/07/2018 Permit Type: Fire-Construction Permit Subc ases Fire Suppression Lot Number: G4 Property: 1330 SANDSTONE DR 9 (210312123004 9)(210312123004) Contacts Contact Type: Applicant Company Name: Meridain Intermountain Full Name: Don Anderson Address: PO Box 3940 331 Metcalf Rd Avon,CO 81620 Email: Dispatch@meridianintermountain.com Contact Type: Property Owner Full Name: BOUCHER, PETER W. &CAROLINE C. Address: Permit Fees Fee Information Account Amount Fire Scope Letter Fee 001-0000.31111.00 $216.00 Payment Information Date Paid Payment Type Amount Fire Scope Letter Fee 09/11/2018 Check $216.00 Paid By:Carolyn Godfrey-Notes:ck#17998 Vail Alarm/Meridian Intermountain FEE TOTAL $216.00 AMOUNT PAID $216.00 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 09/11/2018 -3:53:23 PM-Generated by:cgodfrey 1/1 WorldwideFire Protectionrtijci7 Contacts www.tyco-fire.com Products RAPID RESPONSE Series LFII Residential 4.9 K-factor Concealed Pendent Sprinkler Flat Plate, Wet Pipe an d D r yPipe Systems General The Series LFII Residential Concealed Pendent Sp rinklers (TY3596) has Description been designed with heat sensitivity and water distribution characteristics TYCO RAPID RESPONSE Series LFII proven to help in the control of residen- - Residential 4.9K Concealed Pendent tial fires and to improve the chance for Sp rinklers (TY3596) are decorative, occupants to escape or be evacuated. fast response,fusible solder sp rinklers The Series LFII Residential Con- 0111111 � designed for use in residential occu- cealed Pendent Sp rinklers(TY3596) p ancies such as homes, apartments, are ship p ed with a Disposable Pro- dormitories,and hotels. tective Cap. The Protective Cap is The cover p late assembly conceals temp orarily removed for installation, the sp rinkler operating components and then it can be rep laced to help above the ceiling.The flat profile of the protect the sprinkler while the ceiling NOTICE cover plate provides the optimum aes is being installed or finished. The tip of thetically ap p ealingsp rinkler design. the Protective Cap can also be used The Series LFII Residential Concealed In addition, the concealed design of to mark the center of the ceiling hole Pendent Sprinklers(TY3596)described the Series LFII Residential Concealed into p laster board, ceiling tiles, etc. herein must be installed and main- Pendent Sp rinklers(TY3596) provides by gently p ushing the ceiling p roduct tained in compliance with this docu- 1/2 inch (12,7 mm)vertical adjustment. against the Protective Cap.When the ment and with the applicable standards This adjustment provides a measure of ceiling installation is complete the Pro- of the NationalFire Protection Associa- flexibility when cutting fixed sprinkler tective Cap is removed and the Cover tion(NFPA),inadditionto the standards drops. Plate Assembly installed. of any authorities having jurisdiction. Failure to do so may impair the perfor- The Series LFII Residential Concealed Dry Pipe System Application mance of these devices. Sprink lers are intended for use in the The Series LFII Residential Concealed following scenarios: Pendent Sprinklers offers a laboratory The owner is responsible for main- approved option fordesigning dry p ip e taining their fire protection system • wet and dry p ip eresidential sp rin- residential sp rinklersystems,whereas, and devices in proper operating con- k ler systems for one-and two-fam- most residential sp rinklersare lab ora- dition.Contact the installing contrac- ily dwellings and mobile homes per tory approved for wet systems only. tor or product manufacturer with any NFPA 13D questions. Through extensive testing, it has been • wet and dry pipe residential sprinkler determined that the number of design Sprinkler systems for residential occupancies sp rinklers(hydraulic design area) for p up to and including four stories in the Series LFII Residential Concealed height per NFPA 13R Pendent Sp rinklers (TY3596) need Identification • wet and dry pipe sp rinklersystems not be increased over the number of w for thearesidentialryipep ortions any design sp rinklers (hydraulic design Number (SIN) occupancy per NFPA 13 area)as specified forwet pipe sprinkler systems,as is accustomed fordensity/ TY3596 area sp rinkler systems designed per NFPA 13. Consequently,the Series LFII Residen- tial Concealed Pendent Sprinklers offer the features of non-water filled pipe in IMPORTANT addition to not having to increase the Always refer to Technical Data number of design sprinklers(hydraulic Sheet TFP700 for the "INSTALLER design area)for systems designed to WARNING" that provides cautions NFPA 13, 13D, or 13R. with respect to handling and instal- lation of sprinklersystems and com- ponents. Improper handling and installation can permanentlydamage a sprinkler system or its compo- nents and cause the sprinklerto fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 FEBRUARY 2015 TFP442 TFP442 Page 2 of 6 BODY 1SEALING WRENCH (1/2" NPT) ASSEMBLY RECESS CAP ) JAI1` ' SPRINKLER 0 _ - WRENCHING M i _A AREA SSADDLE \ �� SUPPORT — \ PUSH WRENCH COMPRESSION IN TO ENSURE CUP WITH \_I SCREW ENGAGEMENT ROLL FORMED WITH SPRINKLER THREADS WRENCHING AREA LEVER FIGURE 2 �D Q W—TYPE 18 GUIDE SPRINKLER WRENCH PIN m I I I I I I I I I I° SOLDER LINK V ELEMENT GUIDE PIN HOUSING DEFLECTOR b L_� (OPERATED DEFLECTOR POSITION) SPRINKLER/SUPPORT CUP ASSEMBLY THREAD INTO RETAINER SUPPORT I WITH THREAD CUP UNTIL I DIMPLES O MOUNTING O SURFACE IS FLUSH WITH CEILING EJECTION SPRING ■ �— SOLDER' COVER PLATE/RETAINER --------- COVER TAB ASSEMBLY PLATE FIGURE 1 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENTSPRINKLER(TY3596) 2-1/2" DIA. SPRINKLER— (63,5 mm)� 1/2" (12,7 mm) FACE OF SUPPORT CUP 1/2" THREADED SPRINKLER ASSEMBLY NPT ADJUSTMENT FITTING / OPERATED SPRINKLER j�-1 ii COVE R E 1-7/8"±1/4" — __ PLATE�� (47,6 mm --- — RETAINER 1/8" GAP ±6,4 mm) (3,2 mm) il �� 1 _ — COVER— SPRINKLER— t 7/8"(22,2 mm) RETAINER SUPPORT CUP MOUNTING 1-1/8" (28,6 mm) ASSEMBLY ASSEMBLY 3/16" SURFACE \ ,.,'._.__.•',. (4,8 mm) 3-3/16" DIA. DISPOSABLE DEFLECTOR IN (81,0 mm) TIP PROTECTIVE CAP OPERATED POSITION FIGURE 3 RAPID RESPONSE SERIES LFII RESIDENTIAL CONCEALED PENDENT SPRINKLER(TY3596) INSTALLATION DIMENSIONS/PROTECTIVE CAP/ACTIVATED DEFLECTOR TFP442 Page 3 of 6 Technical Design Criteria Dry Pipe System Water Delivery When using the Series LFII Residen- Data tial Concealed Pendent Sp rinklers TYCO RAPID RESPONSE Series LFII (TY3596)in dry pipe sprinkler systems, Residential Concealed Pendent Sp rin- the time for water delivery must not Approvals klers(TY3596)are UL and C-UL Listed exceed 15 seconds forthe most remote UL and C-UL Listed for installation in accordance with this NYC Approved under MEA 44-03-E-2NSF operating sprinkler. Certified to NSF/ANSI 61 section. Note: When conditions exist that are Obstruction to The TYCO RAPID RESPONSE Series LFII Water Distribution Residential Concealed Pendent Sp rinklers outside the scope of the provided cri- Sp rinklersare to be located in accor- are only Listed with the Series LFII Con- feria,refer to the Residential Sprinkler dance with the obstruction rules of cealed Cover Plates having a factory-ap- Design Guide TFP490 for the manu- p liedfinish. facturer's recommendationsthat may NFPA 13D, 13R, and 13 as applicable Cover Plates can be ordered by following be acceptable to the authority having forresidential sprinklers as well as with the instructions in the Ordering Procedure jurisdiction. the obstruction criteria described within section. the Technical Data Sheet TFP490. Maximum Working Pressure System Types Operational Sensitivity 175 psi(12,1 bar) Per the UL Listing, wet p ip eand dry The sprinklersare to be installed rela- pipe systems may be utilized. Per the Discharge Coefficient C-UL Listing, only wet p ip esystems tive to the ceiling mounting surface as K=4.9 gp m/p sI (70,6 Ipm/bar1t2) may be utilized. shown in Figure 3. T emperatureRating Refer to Technical Data Sheet TFP485 Sprinkler Spacing 160°F (71°C)Sp rinklerwith about the use of residential sprinklers in The minimum sp acing between sp rin- 139°F (59°C)Cover Plate residential dry pipe systems. klers is 8 feet (2,4 m). The maximum Vertical Adjustment CeilingTypes sp acing between sp rinklers cannot 1/2 inch (12,7 mm) yp exceed the length of the coverage area Smooth flat horizontal, or beamed, or n hydraulically slop ed,in accordance with the 2013 (Ref.Table A or B) being ydraulicall y Refer to Ordering Procedure section. Edition of NFPA 13D, 13R, or 13 as calculated(e.g.,maximum 12 feet for a Physical Characteristics applicable. 12 ft.x 12 ft. coverage area,or 20 feet Body Brass for a 20 ft.x 20 ft. coverage area). Cap Bronze Hydraulic Design The Series LFII must not be used Saddle Brass (NFPAI3D and 13R) in applications where the air pres- Sealing Assembly Beryllium Nickel For systems designed to NFPA 13D sure above the ceiling is greater than w/TEFLON or NFPA 13R, the minimum required that below. Down drafts through the Soldered Link Halves Nickel sp rinkler flow rates are given in Support Cup could delay sprinkler Lever Bronze Tables A and B as a function of tern- Compression Screw Brass p erature rating and the maximum operation in a fire situation. Deflector Copper or allowable coverage areas. The Brass sp rinkler flow rate is the minimum Guide Pin Housing. Bronze required discharge from each of the Guide Pins Stainless Steel total number of"design sp rinklers"as or Bronze specified in NFPA 13D or NFPA 13R. Support Cup Steel The number of "design sp rinklers" Cover Plate Copper sp ecified in NFPA 13D and 13R for wet Retainer Brass pip esystems is to be applied when Cover Plate designing dry pipe systems. Ejection Spring Stainless Steel Hydraulic Design Operation (N FPA 13) M For systems designed to NFPA 13, the When exposed to heat from a fire,the number of design sp rinklers is to be CoverPlate,which is normally soldered the four most hydraulically demanding to the Support Cup at three points,falls sp rinklers.The minimum required dis- away to expose the sp rinklerassemb ly. charge from each of the four sp rinklers At this point the Deflectorsupported by is to be the greater of the following: the Arms drop sdown to its operated • the flow rates given in Tables A and position. The fusible link of the sp rin- B as a function of temp erature rat- kler assembly is comprised of two link ing and the maximum allowable cov- halves that are soldered together with erage area a thin layer of solder.When the rated • a minimum discharge of temperature is reached, the solder 0.1 gp m/ft.2 over the design area melts and the two link halves sep arate comp rised of the four (4) most allowing the sp rinkler to activate and hydraulically demanding sp rinklers flow water. for actual coverage areas p rotected by the four(4)sp rinklers The numb erof design sprinklers sp eci- fied in NFPA 13 for wet pipe systems is to be applied when designing dry p ip e systems. TFP442 Page 4 of 6 WET PIPE SYSTEM Minimum Flow and Residual Pressure",3 Maximum Maximum Coverage Spacing Ordinary Temp.Rating Minimum Area Ft. t 160°F (71°C) Ft.x Ft. Deflector to Installation Spacing (m x m) (m) Flow Pressure Ceiling Type Ft. gpm psi (m) (ham) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings 7/8 to 1-1/8 14 x 14 14 13 7.0 inches (4,3 x 4,3) (4,3) (49,2) (0,48) Beamed 16 x 16 16 13 7.0 Ceilings per 8 (4,9 x 4,9) (4,9) (49,2) (0,48) NFPA 13D or Concealed (2 4) 13R, or 13. Installed in 18 x 18 18 17 12.0 beam (5,5 x 5,5) (5,5) (64,3) (0,83) 7/8 to 1-1/8 inches below 20 x 20 20 20 16.7 bottom of (6,1 x 6,1) (6,1) (75,7) (1,15) beam Notes: 1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in gpm(Ipm)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications,the greater of 0.1 gpm/ft?over the design area or the flow in accordance with the criteria in this table must be used. TABLE A WETPIPE SYSTEM SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENTSPRINKLER(TY3596) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA DRY PIPE SYSTEM Minimum Flow and Residual Pressure 2,3 Maximum Maximum Coverage Spacing Ordinary Temp.Rating Minimum Area Ft 160°F (71°C) Ft.x Ft. Deflector to Installation Spacing (m x m) (m) Flow Pressure Ceiling Type Ft. gpm psi (m) (Ipm) (bar) 12 x 12 12 13 7.0 Smooth (3,7 x 3,7) (3,7) (49,2) (0,48) Ceilings - - 7/8 to 1-1/8 14 x 14 14 14 8.2 inches (4,3 x 4,3) (4,3) (53,0) (0,57) Beamed 16 x 16 16 15 9.4 Ceilings per 8 (4,9 x 4,9) (4,9) (56,8) (0,65) NFPA 13D or Concealed (2 4) 13R, or 13. Installed in 18 x 18 18 18 13.5 beam (5,5 x 5,5) (5,5) (68,1) (0,93) 7/8 to 1-1/8 inches below 20 x 20 20 21 18.4 bottom of (6,1 x 6,1) (6,1) (79,5) (1,27) beam Notes: 1. For coverage area dimensions less than or between those indicated,use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated. 2. Requirement is based on minimum flow in gpm(Ipm)from each sprinkler.The associated residual pressures are calculated using the nominal K-factor.Refer to Hydraulic Design under the Design Criteria section. 3. For NFPA 13 residential applications,the greater of 0.1 gpm/ft?over the design area or the flow in accordance with the criteria in this table must be used. TABLE B DRY PIPE SYSTEM RAPID RESPONSE SERIES LFII RESIDENTIAL 4.9 K-FACTOR FLAT PLATE CONCEALED PENDENT(TY3596) NFPA 13D, 13R,AND 13 HYDRAULIC DESIGN CRITERIA TFP442 Page 5 of 6 Installation Step 6. Screw on the Cover Plate Care must be exercised to avoid Assembly until its flange comes in damage before,during,and afterinstal- TYCO RAPID RESPONSESeries LFII contact with the ceiling. lation. Sp rinklers damaged by drop- Residential Concealed Pendent Sp rin- Do not continue to screw on the Cover ping, striking, wrench twist/slippage, klers (TY3596) must be installed in Plate Assembly such that it lifts a or the like,must be rep laced. accordance with this section. ceiling panel out of its normal position. The owner is resp onsible for the General Instructions If the Cover Plate Assembly cannot inspection,testing,and maintenance of Damage to the fusible Link Assembly be engaged with the Mounting Cup theirfire protection system and devices during installation can be avoided by or the Cover Plate Assembly cannot in compliance with this document, as handling the sprink ler by the support be engaged sufficiently to contact the well as with the applicable standards Aso- cup only(i.e.,do not apply pressure to ceiling, the Sp rinkler Fitting must be of the National Fire Protection on t the fusible Link Assembly). repositioned. ciation (e.g., NFPA 25), in addition to the standards of any other authorities A 1/2 inch NPT sp rinkleryoint should be Care and having jurisdiction.Contact the install- obtained with a minimum to maximum ing contractororproduct manufacturer torque of 7 to 14 lbs.-ft.(9,5 to 19,0 Nm). with any questions. Higher levels of torque may distort the Maintenance The owner must assure that the sp rin- sp rinklerinlet with consequent leakage TYCO RAPID RESPO NSE Series LFII klers are not used for hanging any or impairment of the sprinkler. Residential Concealed Pendent Sp rin- objects and that the sprinklers are only Do not attempt to compensate for klers (TY3596) must be maintained cleaned by means of gently dusting insufficient adjustment in the Cover and serviced in accordance with this with a feather duster; otherwise,non- Plate / Retainer Assembly by under- section. operation in the event of a fire or inad- or over-tightening the Sprinkler. Read- Before closing a fire protection system vertent operation may result. just the position of the sp rinklerfitting main control valve for maintenance Automatic sprinkler systems should be to suit. work on the fire p rotection system inspected,tested,and maintained bya Step 1. The sprinkler must only be which it controls, permission to shut qualified Inspection Service in accor- installed in the pendent position and down the affected fire protection dance with local requirements and/or with the centerline of the sprinkler p er- system must be obtained from the national codes. pendicular to the mounting surface. proper authorities and all personnel Step 2. Remove the Protective Cap. who may be affected by this action must be notified. Step 3. With p ip e thread sealant Absence of a CoverPlate may delay the applied to the pipe threads,and using the W-Type 18 Wrench shown in Figure sprinkler operation in a fire situation. 2, install and tighten the Sp rinkler/ When properly installed, there is a Support Cup Assembly into the fitting. nominal 1/8 inch (3,2 mm) air gap The W-Type 18 Wrench will accept a between the lip of the Cover Plate and 1/2 inch ratchet drive. the ceiling, as shown in Figure 3. This Step 4. Replace the Protective Cap by air gap is necessary for proper op era p ushing it upwards until it bottoms out tion of the sp rinkler by allowing heat against the Support Cup.The Protec flow from a fire to pass below and tive Cap help s prevent damage to the above the Cover Plate to help assure Deflectorand Guide Pins during ceiling appropriate release of the Cover Plate installation and/or during application of in a fire situation. If the ceiling is to be the finish coating of the ceiling. It may rep ainted after the installation of the also be used to locate the center of the Sp rinkler,care must be exercised to clearance hole by gently p ushing the ensure that the new paint does not seal ceiling material against the center p oint off any of the air gap. of the Cap. Factory painted Cover Plates must not Note:As long as the protective Cap be repainted.They should be rep laced, remains in place, the system is considif necessary, by factory p ainted ered to be"Out Of Service." units. Non-factory ap p liedp aint may adversely delay or p revent sp rinkler Step 5. After the ceiling has been operation in the event of a fire. completed with the 2-1/2 inch (63 mm) Do not p ull the Cover Plate relative to diameter clearance hole and in p rep the Enclosure.Separation may result. aration for installing the Cover Plate Assembly, remove and discard the Pro- Sp rinklers which are found to be tective Cap,and verify that the Deflec- leaking or exhibiting visible signs of tor moves up and down freely. corrosion must be rep laced. If the sprinkler has been damaged and Automatic sp rinklers must never be the Deflector does not move up and p ainted,p lated,coated, or otherwise down freely, replace the entire sprinkler altered after leaving the factory. Modi- assembly. Do not attempt to modify or fied or over heated sprinklers must be repair a damaged sprinkler. rep laced. TFP442 Page 6 of 6 Limited Ordering Warranty Procedure Forwarranty terms and conditions,visit Contact your local distributor for www.tyco-fire.com. availability. When p lacing an order, indicate the full product name and p art number(P/N). Sprinkler Assemblies Specify: Series LFII (TY3596) 4.9K Residential Concealed Pendent Sp rin- kler without Cover Plate Assembly, P/N 51-112-1-160 Cover Plate Assemblies Specify: Cover Plate Assembly with (specify) finish for the Series LFII (TY3596) 4.9K Residential Concealed Pendent Sprinkler, P/N (sp ecify): Ivory(RAL1015) P/N 56-202-0-135 Beige(RAL1001) P/N 56-202-2-135 Pure White*(RAL9010) P/N 56-202-3-135 Signal White**(RAL9003) P/N 56-202-4-135 Grey White(RAL9002) P/N 56-202-5-135 Brown(RAL8028) P/N 56-202-6-135 Black(RAL9005) P/N 56-202-7-135 Brushed Brass P/N 56-202-8-135 Brushed Chrome P/N 56-202-9-135 Custom Paint P/N 56-202-X-135 * Eastern Hemisphere sales only ** Previously knownas Bright White Note: All Custom Cover Plates are paintedusing Sherwin Williams Interior Latex Paint. Contact Tyco Customer Service with any questions related to custom orders. Sprinkler Wrench Sp ecify:W-Type 18 Sprink ler Wrench, P/N 56-000-1-265 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdal e,PA 19446 I Telephone+1-215-362-0700 Copyright©2015 Tyco Fire Products, LP. All rights reserved. tyco TEFLON is trademark of The DuPont Corporation. Fire Protection Products