Loading...
HomeMy WebLinkAboutLoad Calc 3996 Lupine Dr.pdf City of Naperville Application# 1 Naperville W Address: 3996 Lupine Drive 2017 Dwelling Unit Electric Service & Feeder Load Calculator 220.12 General Lighting Load 3 va/ft2 of floor area,including unused space adaptable for future use. Floor Area= 3000 ft2 9,000 va Basement Floor Area= 2600 ft2 7,800 va 220.52(A) Small Appliance Load 1500 va for each 20 amp branch circuit required per 210.1(C)(1)in EACH kitchen, pantry, breakfast room,dining room,or similar areas. #of Small Appliance Branch Circuits= 4 X 1500 va= 6,000 va 220.52(B) Laundry Load #of Laundry Branch Circuits= 1 x 1500 va= 1,500 va Total General Lighting&Appliance Load= 24,300 va 220.42 Lighting Load Feeder Demand Factors First 3000 or less at a00% 3,000 va From 3001 to 120,000 at 35% 7,455 va Remainder over 120,000 at 25% - va Total Lighting Demand Load= 10,455 va 220.54 Electric Clothes Dryers Qty 1 Electric Dryer#1 5.50 kw 5,500 w Qty 0 Electric Dryer#2 - kw - w 220.55 Electric Cooking-Ranges,Stove Tops and Wall Ovens Qty 1 Wall Oven Nameplate 5.50 kw Qty 1 Electric Range Nameplate 7.50 kw Qty 0 Wall Oven Nameplate - kw Electric Cooking Demand Load= 8,450 w 220.51 Fixed Electric Space Heating Loads or Air Conditioning Load: Fixed Electric Space Heat#1 - kw AC#1/Geo - kva Fixed Electric Space Heat#2 - kw AC#2/Geo - kva Fixed Electric Space Heat#3 - kw AC#3/Geo - kva Fixed Electric Space Heat#4 - kw AC#4/Geo - kva Fixed Electric Space Heat#5 - kw AC#5/Geo - kva Total Heat&AC Load= - va 220.14 Appliance load--Dwelling Units Qty Description va(watts) Qty Description va(watts) 1 Central Furnace 1,200 1 Freezer 1,440 1 Dishwasher 1,200 1 Wine Cooler 360 1 Refrigerator 1,440 1 Spa/Hot Tub 12,000 1 Microwave 2,580 0 - 1 Range Hood 240 0 - 4 Vent Fan 400 0 - 2 Paddle Fan 180 0 - Total Connected Appliance Load= 20,040 va 220.53 Appliance load--Dwelling Units Total Appliance Demand Load= 15,030 va 220.50 Motor Loads @ 120 Volts Qty Description va(watts) Qty Description va(watts) 1 1/3hpGar/DoorOpener 250 0 - 1 1/3HPpump/Eject Pum! 250 0 - 0 0 - 0 - 0 - Total Motor Load= 500 va 430.24 Several Motors or a Motor(s)and Other Load(s) 25%of Largest Motor Load= 63 va Total Motor Demand Load= 563 va TOTAL CALCULATED DEMAND LOAD in Volt-amperes= 39,997 va TOTAL CALCULATED DEMAND LOAD in AMPS @120/240V 1ph3W= 167 amps EXISTING SERVICE SIZE 200 AMPS MINIMUM SERVICE SIZE 200 AMPS /ICE SIZE REQUESTED= 200 amps