HomeMy WebLinkAboutB18-0096_Electrical Approved Plans_1537562915.pdf' ' ISSUE LOG KEY: # DATEISSUE LOG ELECTRICAL SHEET INDEX TITLE COVER SHEETE-000 DESIGN DEVELOPMENT02.19.2018ISSUED AS PART OF A SET ' ' NOT PART OF SET ' ' ISSUED FOR INFORMATION ONLY* √ √ √ √ √ ELECTRICAL SCHEDULESE-001 ELECTRICAL PLAN - PARKING LEVELE-201 ELECTRICAL PLAN - LEVEL 2E-203 ABBREVIATIONSPOWER SYMBOLS SINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE GFCI DUPLEX RECEPTACLE DUPLEX RECEPTACLE; HALF SWITCHED ISOLATED GROUND DUPLEX RECEPTACLE WALL MOUNTED SPECIAL OUTLET AS NOTED SPECIAL OUTLET AS NOTED JUNCTION BOX WALL MOUNTED JUNCTION BOX FLOOR MOUNTED JUNCTION BOX DUPLEX RECEPTACLE MOUNTED ABOVE COUNTERC FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM DIVISION 15 EQUIPMENT POWER CONNECTION FUSED DISCONNECT NON FUSED DISCONNECT MOTOR STARTER ENCLOSED CIRCUIT BREAKER PULL BOX PUSH BUTTON TRANSFORMER PANELBOARD OR LOADCENTER CONTACTOR ELECTRIC MOTOR METER THERMOSTAT ATS AUTOMATIC TRANSFER SWITCH ONE-LINE DIAGRAM SYMBOLS CIRCUIT HOMERUN CONDUIT RUN CONDUIT RUN BELOW GRADE CONDUIT UP CONDUIT DOWN DISCONNECT SWITCH FUSE CIRCUIT BREAKER CURRENT TRANSFORMER POTENTIAL TRANSFORMER METER SURGE PROTECTION DEVICE VOLT-METER SELECTOR SWITCH GROUND GF GROUND FAULT PROTECTION AMP-METER ST SHUNT TRIP NORMALLY OPEN CONTACT NORMALLY CLOSED CONTACT COLD WATER GROUND CONNECTION BUILDING STEEL GROUND CONNECTION TIMER SWITCH MULTI-OUTLET PLUG STRIP TIME CLOCK PHOTO-CELL SWITCH THERMAL OVERLOAD SWITCH VARIABLE SPEED SWITCH KEY SWITCH LIGHTING FIXTURE SYMBOLS RECESSED LIGHTING FIXTURE WALL MOUNTED LIGHT WALL MOUNTED UP-LIGHT PENDANT MOUNTED LIGHT SURFACE MOUNTED LIGHT DIRECTIONAL/ADJUSTABLE RECESSED LIGHTING FIXTURE MONO-POINT LIGHTING FIXTURE RECESSED STEP LIGHT FLUORESCENT STRIP LIGHT WALL MOUNTED LINEAR FLUORESCENT LIGHT RECESSED OR SURFACE MOUNTED FLUORESCENT TROFFER FIXTURE WITH EMERGENCY BACKUP OR ON EM CIRCUIT WALL MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN EMERGENCY LIGHTS CEILING MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH DOOR JAMB SWITCH LIGHTING CONTROL SYMBOLS EXTERIOR POLE MOUNTED LIGHT EXTERIOR POST (BOLLARD) MOUNTED LIGHT DAYLIGHT PHOTO SENSORDL KEY SWITCH LV VARIABLE SPEED SWITCH DIMMER THREE-WAY DIMMER LOW VOLTAGE SWITCH WALL OCCUPANCY SENSOR/SWITCH THERMAL OVERLOAD SWITCH OCCUPANCY SENSOR - WALL MOUNTED OCCUPANCY SENSOR - CORRIDOR CEILING MOUNTED S S3 ST SO D 3 D SV SK SJ S4 SK SV ST S PC TC TS A V SPD M T C T PB CB N -- J J J NOTE: ALL SYMBOLS SHOWN ON LEGEND ARE NOT NECESSARILY USED. OS OS OCCUPANCY SENSOR - CEILING MOUNTED OS NOTES: · LIGHT LINEWEIGHT INDICATES EXISTING. · HATCHED AREAS INDICATE DEMOLITION. · 'C' ADJACENT TO A DEVICE INDICATES MOUNTING ABOVE COUNTERTOP. AFC AFF AFG AHJ - ABOVE FINISHED CEILING - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE - AUTHORITY HAVING JURISDICTION AL - ALUMINUM AWG AP - ACCESS POINT - AMERICAN WIRE GAUGE BFG BMS BAS - BUILDING AUTOMATION SYSTEM - BELOW FINISH GRADE - BUILDING MANAGEMENT SYSTEM C CATV CCTV - CONDUIT - COMMUNITY (CABLE) ANTENNA TELEVISION SYSTEM - CLOSED CIRCUIT TELEVISION CKT - CIRCUIT CPU - CENTRAL PROCESSING UNIT CT - CURRENT TRANSFORMER DISP - GARBAGE DISPOSAL DW - DISHWASHER (E) - EXISTING EM - EMERGENCY EWC - ELECTRIC WATER COOLER FBO GFI FA FACP GRD GC - FIRE ALARM - FIRE ALARM CONTROL PANEL - FURNISHED BY OTHERS - GENERAL CONTRACTOR - GROUND FAULT CIRCUIT INTERRUPTER - GROUND IAW IN ACCORDANCE WITH- IC IDF IG IR LAN - INTERMEDIATE CROSS-CONNECT - INTERMEDIATE DISTRIBUTION FRAME - ISOLATED GROUND - INFRARED - LOCAL AREA NETWORK NIC MDF (N) MAIN DISTRIBUTION FRAME- NEW- NOT IN CONTRACT- NL NIGHT LIGHT- NTS NOT TO SCALE- OC PA ON CENTER- PUBLIC ADDRESS- REF REFRIGERATOR- TVSS TTB TELECOMMUNICATIONS TERMINAL BOARD- TRANSIENT VOLTAGE SURGE SUPPRESSOR- TVTB TELEVISION TERMINAL BOARD- UG UNO W V UNDERGROUND- UNLESS NOTED OTHERWISE- VOLT- WATT- WP XP WAN WLAN WAP WIDE AREA NETWORK- WIRELESS ACCESS POINT- WIRELESS LOCAL AREA NETWORK- WEATHERPROOF- EXPLOSIONPROOF- +18" DEVICE ABOVE FINISH FLOOR (VERIFY W/ ARCH ELEVS) MOUNTING HEIGHT TO CENTERLINE OF- FIRE ALARM SYMBOLS FIRE ALARM CONTROL PANEL REMOTE ANNUNCIATOR PANEL SMOKE DETECTOR HEAT DETECTOR COMBO SMOKE/HEAT DETECTOR FIRE ALARM HORN FIRE ALARM STROBE FIRE ALARM COMBO HORN/STROBE FIRE ALARM PULL STATION S FIRE ALARM SPEAKER S FIRE ALARM COMBO SPEAKER/STROBE FIREMAN'S PHONE JACK DUCT DETECTOR SPRINKLER SYSTEM FLOW SWITCH SPRINKLER SYSTEM TAMPER SWITCH FIRE/SMOKE DAMPERFSD FT FF F F HH ANN FACP H SMOKE DETECTOR W/ SOUNDER BASESB CO SMOKE DETECTOR W/ CARBON MONOXIDE BD T BD R BEAM TYPE SMOKE DETECTOR TRANSMITTER BEAM TYPE SMOKE DETECTOR RECEIVER INDIVIDUAL ADDRESSABLE MODULE MONITORED RELAY POST-INDICATOR VALVE CARBON MONOXIDE DETECTOR PIV MR IAM CO FIRE ALARM CHIME FIRE ALARM CHIME/STOBE REMOTE TESTER SWITCHRTS LOW TEMPERATURE SENSORLT ELECTRICAL SYSTEMS LEGEND ELECTRONIC SAFETY & SECURITY SYMBOLS F MULTI-OUTLET WIREWAY VOICE/DATA SYMBOLS COMBO PHONE/DATA OUTLET TELEPHONE WALL OUTLET DATA WALL OUTLET TELEPHONE FLOOR OUTLET DATA FLOOR OUTLET COMBO PHONE/DATA FLOOR OUTLET DOUBLE TELEPHONE WALL OUTLET DATA WALL OUTLET DOUBLE COMBO PHONE/DATA OUTLET VOICE/DATA/FIBER OUTLETOF POINT OF SALE (POS) OUTLETPOS AUTOMATED TELLER MACHINE (ATM) STATIONATM PUBLIC PAYPHONE OUTLETPP ELEVATOR PHONE OUTLETE POWER/TELECOM POLE WIRELESS LAN (WI-FI) ACCESS POINT OUTLET FAX/COPIER OUTLET EMERGENCY SERVICES PHONE OUTLETEM F C L CEILING MOUNTED CAMERA WALL MOUNTED CAMERA MAGNETIC DOOR CONTACT SWITCH ADA ACCESS CONTROL MAIN PANELADA CRP CARD READER - PROXIMITY S ELECTRIC LOCK - STRIKE LM ELECTRIC LOCK - MAGNETIC LR ELECTRIC LATCH / ROD RETRACTOR SM MAGNETIC DOOR CONTACT SWITCH PANIC BUTTONP CORNER MOUNTED CAMERA 180° VIEW DOME CAMERA 360° VIEW DOME CAMERA HEMISPHERIC DOME FISHEYE CAMERA 180° 360° FE INTRUSION MOTION SENSOR SECURITY KEYPAD MON CCTV MONITOR ACCESS CONTROL MAIN PANELACP EXIT PANIC/CRASH BAR SENSORREX SECURITY CENTRAL PROCESSING UNITCPU SECURITY/ACCESS CONTROL WORKSTATIONWS K I CRS CARD READER - PROXIMITY ELECTRICAL PLAN - LEVEL 1E-202 ELECTRICAL PLAN - LEVEL 3E-204 ELECTRICAL PLAN - LEVEL 4E-205 ELECTRICAL UNIT PLAN - 1 BRE-311 ELECTRICAL PLAN - ROOFE-206 ELECTRICAL UNIT PLAN - STUDIOE-301 ELECTRICAL UNIT PLAN - STUDIOE-302 ELECTRICAL UNIT PLAN - STUDIOE-304 ELECTRICAL UNIT PLAN - STUDIOE-303 ELECTRICAL UNIT PLAN - STUDIOE-305 ELECTRICAL UNIT PLAN - STUDIOE-306 ELECTRICAL UNIT PLAN - 1 BRE-308 ELECTRICAL UNIT PLAN - STUDIOE-307 ELECTRICAL UNIT PLAN - 1 BRE-309 ELECTRICAL UNIT PLAN - 1 BRE-310 ELECTRICAL UNIT PLAN - 1 BRE-312 ELECTRICAL UNIT PLAN - 1 BR ELECTRICAL UNIT PLAN - 1 BR ELECTRICAL UNIT PLAN - 1 BR E-313 ELECTRICAL UNIT PLAN - 2 BR E-314 E-315 E-316 ELECTRICAL DIAGRAMSE-400 ELECTRICAL DIAGRAMSE-401 √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √√ √ √ GENERAL NOTES: 1. THESE DRAWINGS ACCOMPANY THE PUBLISHED CONSTRUCTION DOCUMENT SPECIFICATION BOOK (PROJECT MANUAL). 2. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK. 3. REVIEW ARCHITECTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID. 4. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 5. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND ORDINANCES. 6. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 7. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS. 8. VERIFY EXACT LOCATIONS OF EXISTING AND NEW UNDERGROUND UTILITIES, PIPING AND RACEWAY SYSTEMS PRIOR TO TRENCHING. PROVIDE NECESSARY TRENCHING, BACKFILL, EXCAVATION, SUPPORTS, SERVICE FEEDERS (CONDUIT AND/OR WIRE), PULLBOXES, TRANSFORMER PADS, SAWCUTTING AND PATCHING, CONCRETE/PAVING, ETC. REQUIRED. BACKFILL TRENCHES TO 90 PERCENT COMPACTION AND PATCH TO MATCH EXISTING. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT UTILITY COMPANY DRAWINGS AND REQUIREMENTS. ELECTRICAL CONTRACTOR IS TO SUBMIT A COMPLETE CONSTRUCTION DRAWING SET TO THE ELECTRICAL UTILITY COMPANY WITH-IN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THEIR REVIEW, APPROVAL, CONSTRUCTION SCHEDULING AND INSTALLATION OF THE UTILITY TRANSFORMER WITH THE UTILITY COMPANY. NOTIFY OWNER OF ANY SCHEDULING CONFLICTS. 9. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN. 10. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION. 11. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED. 12. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 13. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. 14. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 20 AMPERES FOR DUPLEX RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT. 15. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS, UNLESS NOTED OTHERWISE. CONNECTORS SHALL BE INSULATED THROAT TYPE. MINIMUM RACEWAY SIZE IS 3/4”. ALL FEEDERS SHALL BE INSTALLED IN RACEWAY CONFIGURATIONS SHOWN ON ONE-LINE. BRANCH CIRCUITS 25A AND LARGER SHALL BE INSTALLED IN INDIVIDUAL RACEWAYS. BRANCH CIRCUITS 20A AND SMALLER MAY BE GROUPED INTO RACEWAYS AS TO NOT EXCEED 6 CURRENT-CARRYING 75-DEGREE CONDUCTORS, OR 9 CURRENT-CARRYING 90-DEGREE CONDUCTORS, IN A SINGLE RACEWAY. METAL CLAD CABLE IS PERMITTED. 16. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUAL, AND SHALL BE IDENTIFIED AT ALL JUNCTION, PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT, ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. 17. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. 18. PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS. 19. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVED FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT. 20. FIRE ALARM, SOUND, TELEPHONE, COMPUTER AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1” SHALL HAVE LONG RADIUS SWEEPS (12 TIMES THE DIAMETER). 21. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER. 22. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 23. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE. √ √PERMIT ISSUE√ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √√ √ √ √ √07.24.2018TECHNOLOGY ENLARGED PLANSE-402 TECHNOLOGY RISER DIAGRAMSE-500 TECHNOLOGY RISER DIAGRAMSE-501 TECHNOLOGY DIAGRAMSE-600 √ √ √ √ ELECTRICAL SITE PLANE-100 √ TECHNOLOGY DIAGRAMSE-601 √ ELECTRICAL SCHEDULESE-002 √ Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-000 ELECTRICAL COVER SHEET 09/21/18 MECHANICAL EQUIPMENT SCHEDULE MARK DESCRIPTION VOLT / PHASE HP WATTS FLA MCA MOCP DISCONNECT/ FUSE SIZE FEEDER CIRCUIT SPECIFIC NOTES B-1 BOILER 120/1 - 600 5.0 15.0 20A1P 1P MOTOR RATED SWITCH 20A(2WG) M1-1 M1-3 M1-5 WH-1 DOMESTIC HOT WATER 120/1 - 480 4.0 5.0 20A1P 1P MOTOR RATED SWITCH 20A(2WG) M1-7 M1-9 P-1 HEATING WATER CIRC PUMP 208/1 - 1,380 6.6 8.3 20A2P 30A, 2P, NF 20A(3WG) SEE PLANS P-2 BOILER INJECTION PUMP 208/3 - 1,350 3.8 4.7 20A3P 30A, 3P, NF 20A(4WG) SEE PLANS P-3 WATER HEATER INJECTION PUMP 120/1 - 400 3.3 4.2 20AP 1P MOTOR RATED SWITCH 20A(2WG) M1-37 M1-39 P-4 DOMESTIC HOT WATER RECIRC PUMP 120/1 - 280 2.3 2.9 20A1P 1P MOTOR RATED SWITCH 20A(2WG)M1-2 P-5 SNOW MELT CIRC PUMP 208/3 - 600 1.7 2.1 20A3P 30A, 3P, NF 20A(4WG) M1-4,6,8 P-6 ELEVATOR SUMP PUMP 120/1 1/2 1,176 9.8 12.3 20A1P 1P MOTOR RATED SWITCH 20A(2WG) M1-10 GF-1 GLYCOL FEEDER 120/1 - 84 0.7 0.9 20A1P 1P MOTOR RATED SWITCH 20A(2WG) M1-12 MAU-1 CORRIDOR MAKE-UP AIR UNIT 208/1 3/4 2,392 7.6 11.5 20A2P 30A, 2P, FUSED 20A(3WG) M1-30,32 MAU-2 LAUNDRY MAKE-UP AIR UNIT 208/3 2 3,922 7.5 10.9 20A3P 30A, 3P, FUSED 20A(4WG) M1-34,36,38 EF-1 CEILING EXHAUST FAN #1 120/1 - 17 0.1 0.2 20A1P 1P MOTOR RATED SWITCH 20A(2WG) SEE PLANS EF-2 CEILING EXHAUST FAN #2 120/1 - 27 0.2 0.3 20A1P 1P MOTOR RATED SWITCH 20A(2WG) SEE PLANS EF-3 WALL EXHAUST FAN #3 120/1 1/4 696 5.8 7.3 20A1P 1P MOTOR RATED SWITCH 20A(2WG) M1-40 EF-4 WALL EXHAUST FAN #4 120/1 1/20 96 0.8 1.0 20A1P 1P MOTOR RATED SWITCH 20A(2WG) M1-40 EF-5 CEILING EXHAUST FAN #5 120/1 - 126 1.1 1.3 20A1P 1P MOTOR RATED SWITCH 20A(2WG) SEE PLANS EF-6 DRYER EXHAUST FAN #6 120/1 - 72 0.6 0.8 20A1P 1P MOTOR RATED SWITCH 20A(2WG) M1-28 UH-1 UNIT HEATER #1 120/1 - 16 0.1 0.2 20A1P 1P MOTOR RATED SWITCH 20A(2WG) SEE PLANS CUH-1 RECESSED CABINET UNIT HEATER #1 120/1 1/10 192 1.6 2.0 20A1P 1P MOTOR RATED SWITCH 20A(2WG) M1-26 CUH-3 CEILING CABINET UNIT HEATER #3 120/1 1/15 132 1.1 1.4 20A1P 1P MOTOR RATED SWITCH 20A(2WG) M1-22 CUH-4 CEILING CABINET UNIT HEATER #4 120/1 1/10 192 1.6 2.0 20A1P 1P MOTOR RATED SWITCH 20A(2WG) M1-24 GENERAL NOTES: A. SEE SPECIFICATIONS FOR ELECTRICAL DIVISION AND MECHANICAL DIVISION MOTOR STARTER COORDINATION. B. PROVIDE PHASE PROTECTION FOR ALL THREE PHASE MOTORS ABOVE 7-1/2 HP. C. PROVIDE ALL EXTERIOR DISCONNECTS WITH NEMA 3R RATING. D. WHEN EQUIPMENT IS LISTED WITH ONLY A HORSEPOWER RATING THE DISCONNECT AND FEEDER ARE SIZED PER THE N.E.C. SPECIFIC NOTES: (1) (2) (3) (4) LUMINAIRE SCHEDULE TYPE DESCRIPTION MOUNTING RECESS DEPTH LAMPS INPUT WATTS VOLT MANUFACTURER CATALOG NUMBER SPECIFIC NOTESQTY TYPE LUMENS G1 GARAGE PENDANT WITH INTEGRAL MOTION SENSOR, TYPE 5 DISTRIBUTION, 3000K PENDANT - -LED AS SUPPLIED, 3000K 4,575 37 120-277 LITHONIA DSXPG LED 20C 530 30K T5M MVOLT PIR S1 SURFACE MOUNTED ROUND FIXTURE, 90 CRI, 3000K SURFACE - -LED AS SUPPLIED, 3000K 1,800 20 120-277 JUNO JSF 13IN 18LM 30K 90CRI MVOLT ZT WH S2 2' SURFACE MOUNTED LINEAR FIXTURE, 90 CRI, 3000K WALL - -LED AS SUPPLIED, 3000K 1,490 19.5 120-277 WAC LIGHTING WS-63724-30 AL S3 3' SURFACE MOUNTED LINEAR FIXTURE, 90 CRI, 3000K WALL - -LED AS SUPPLIED, 3000K 2,330 28.5 120-277 WAC LIGHTING WS-63736-30 AL S4 4' LED STRIP LIGHT, 80 CRI, 3500K SURFACE - -LED AS SUPPLIED, 3500K 4,146 38 120-277 LITHONIA CDS L48 MVOLT DM 35K 80CRI WH S5 ELEVATOR PIT LIGHT SURFACE - -LED AS SUPPLIED, 4000K 6,000 45 120 LITHONIA FEM L48 6000LM LPAFL MD 120 GZ10 40K 80CRI WLFEND X1 EXIT SIGN SURFACE - - LED AS SUPPLIED - 0.8 120-277 LITHONIA EXR LED M6 GENERAL NOTES: A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS SHALL NOT QUOTE PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS AND ELECTRICAL DIVISION SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY DRAWINGS AND SPECIFICATIONS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING. B. REFER TO DRAWINGS FOR FIXTURES REQUIRING EMERGENCY BATTERY BACKUP OPTION (SHOWN BY HATCH IN/OVER SYMBOL). MINIMUM LIGHT OUTPUT FOR EM BALLAST SHALL BE 600 LUMENS. C. ALL FLUORESCENT LAMPS ARE TO BE 3500° KELVIN COLOR TEMPERATURE SPECIFIC NOTES: (1) (2) (3) (4) SITE LUMINAIRE SCHEDULE TYPE DESCRIPTION MOUNTING LAMPS INPUT WATTS VOLT MANUFACTURER CATALOG NUMBER SPECIFIC NOTESQTY TYPE LUMENS E1 EXTERIOR WALL SCONCE WALL -LED AS SUPPLIED, 3000K 3,276 25 120-277 LITHONIA WST LED P2 30K VW MVOLT PIR E2 EXTERIOR PATH LIGHT SURFACE -LED AS SUPPLIED, 3000K 435 12 120 STRUCTURA MAC-42-L30-SO-S*-C*-120-STD R1 EXTERIOR RECESSED CAN ABOVE DOORS RECESSED -LED AS SUPPLIED, 3000K 1,020 14 120-277 LITHONIA WF6 LED 30K MVOLT GENERAL NOTES: A. THE LUMINAIRE SCHEDULE CAN NOT BE USED INDEPENDENTLY OF THE DRAWINGS AND SPECIFICATIONS TO OBTAIN LUMINAIRE COSTS. THE INDIVIDUAL ESTABLISHING LUMINAIRE COSTS SHALL NOT QUOTE PRICING WITHOUT FIRST SEEING APPLICABLE ELECTRICAL DRAWINGS AND ELECTRICAL DIVSION SPECIFICATIONS. THE CONTRACTOR IS REPONSIBLE FOR PROVIDING NECESSARY DRAWINGS AND SPECIFICATIONS TO THE INDIVIDUAL QUOTING LUMINAIRE PRICING. B. REFER TO DRAWINGS FOR FIXTURES REQUIRING EMERGENCY BATTERY BACKUP OPTION (SHOWN BY HATCH IN/OVER SYMBOL). MINIMUM LIGHT OUTPUT FOR EM BALLAST SHALL BE 600 LUMENS. SPECIFIC NOTES: (1) (2) (3) (4) Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-001 ELECTRICAL SCHEDULES 09/21/18 DISTRIBUTION PANEL:VOLTAGE: 120/208V, 3PH, 4W SWB MINIMUM BUS: 2000 LOCATION: MAIN: ELEC ROOM 2000/3 CB MOUNTING: MINIMUM AIC: SURFACE 65,000 PANELS/RISERS MOTORS/EQUIPMENT PANEL SUBTOTAL DEMAND PANEL TOTALMARK: M1 P1 L1 P3 DP1 DP3 ELEV-1 OCPD: 200/3 CB 250/3 CB 70/3 CB 250/3 CB 600/3 CB 600/3 CB 110/3 CB RESIDENTIAL 0 0 0 0 175,482 180,924 356406 100% 356406 LIGHTING 0 144 4,259 0 0 0 0 4403 125% 5504 RECEPTACLES 0 10,800 0 3,070 0 0 0 13870 NEC 220 11935 LARGEST MOTOR 3,921 0 0 0 0 0 16,625 16625 25% 4156 MOTORS 17,799 0 0 0 0 0 0 34424 100% 34424 EQUIPMENT 3,468 6,000 0 13,654 0 0 0 23122 100% 23122 APPLIANCES 0 15,000 0 15,000 0 0 0 30000 >6 19500 PANEL TOTAL (KVA): 455.0 PANEL TOTAL (A): 1264 PANEL: M1 VOLTAGE: 120/208V, 3PH, 4W MINIMUM BUS: 150 LOCATION: ELEC ROOM MAIN: MLO MOUNTING: SURFACE MINIMUM AIC: 42,000 NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B C POLE TRIP A B C TRIP POLE A B C 1 600 E B-1 1 20 + 20 1 M P-4 280 2 3 600 E B-1 1 20 + 20 3 M P-5 200 4 5 600 E B-1 1 20 + - - M - 200 6 7 480 E WH-1 1 20 + - - M - 200 8 9 480 E WH-1 1 20 + 20 1 M P-6 1176 10 11 690 M P-1 2 20 + 20 1 M GF-1 84 12 13 690 M - - - + 20 1 E UH-1 (x8) 128 14 15 690 M P-1 2 20 + 20 1 E UH-1 (x4) 64 16 17 690 M - - - + 20 1 M EF-2 - TRASH 27 18 19 450 M P-2 2 20 + 20 1 M EF-5/EF-1/EF-2 - MECH 197 20 21 450 M - - - + 20 1 E CUH-3 132 22 23 450 M - - - + 20 1 E CUH-4 192 24 25 450 M P-2 2 20 + 20 1 E CUH-1 192 26 27 450 M - - - + 20 1 M EF-6 (x10) 720 28 29 450 M - - - + 20 2 M MAU-1 1196 30 31 450 M P-2 2 20 + - - M - 1196 32 33 450 M - - - + 20 3 LM MAU-2 1307 34 35 450 M - - - + - - LM - 1307 36 37 400 M P-3 1 20 + - - LM - 1307 38 39 400 M P-3 1 20 + 20 1 M EF-3/EF-4 792 40 41 SPARE 1 20 + 20 1 SPARE 42 43 SPARE 1 20 + 20 1 SPARE 44 45 SPARE 1 20 + 20 1 SPARE 46 47 SPARE 1 20 + 20 1 SPARE 48 49 SPACE + SPACE 50 51 SPACE + SPACE 52 53 SPACE + SPACE 54 55 SPACE + SPACE 56 57 SPACE + SPACE 58 59 SPACE + SPACE 60 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 0 0 125% 0 B. (R) RECEPTACLES 0 0 NEC 220 0 C. (LM) LARGEST MOTOR 3921 3921 25% 980 D. (M) MOTORS (ALL) 17799 17799 100% 17799 E. (E) EQUIPMENT 3468 3468 100% 3468 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 (1) PANEL TOTAL (KVA): 22.2 (2) (3) PANEL TOTAL (A): 62 (4) (5) PANEL: P1 VOLTAGE: 120/208V, 3PH, 4W MINIMUM BUS: 150 LOCATION: ELEC ROOM MAIN: MLO MOUNTING: SURFACE MINIMUM AIC: 42,000 NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B C POLE TRIP A B C TRIP POLE A B C 1 1080 R PARKING LEVEL 1 20 + 20 1 R LEVEL 1 CORRIDOR 720 2 3 1620 R PARKING LEVEL 1 20 + 20 1 R LEVEL 1 LOBBY 720 4 5 900 R MECH ROOM 1 20 + 20 1 R LEVEL 1 ELEC ROOM 360 6 7 900 R ELEC ROOM 1 20 + 20 1 R LEVEL 1 OFFICE 900 8 9 180 R EAST STAIR 1 20 + 20 1 R LEVEL 2 CORRIDOR 720 10 11 180 R WEST STAIR 1 20 + 20 1 R LEVEL 2 ELEC ROOM 360 12 13 1260 R EXTERIOR 1 20 + 20 1 A LEVEL 2 - DRYER (1) 1500 14 15 360 R ELEVATOR REC 1 20 + 20 1 A LEVEL 2 - DRYER (1) 1500 16 17 1500 A LEVEL 1 - DRYER (1) 1 20 + 20 1 A LEVEL 2 - DRYER (1) 1500 18 19 1500 A LEVEL 1 - DRYER (1) 1 20 + 20 1 A LEVEL 2 - WASHER (1) 1500 20 21 1500 A LEVEL 1 - DRYER (1) 1 20 + 20 1 A LEVEL 2 - WASHER (1) 1500 22 23 1500 A LEVEL 1 - WASHER (1) 1 20 + 20 1 E LEVEL 2 - VENDING 1500 24 25 1500 A LEVEL 1 -WASHER (1) 1 20 + 20 1 E LEVEL 2 - VENDING 1500 26 27 1500 E LEVEL 1 - VENDING 1 20 + 20 1 R LEVEL 2 - LAUNDRY 180 28 29 1500 E LEVEL 1 - VENDING 1 20 + 20 1 L SITE LIGHTING 144 30 31 180 R LEVEL 1 - LAUNDRY 1 20 + 20 1 R GENERATOR REC 180 32 33 SPARE 1 20 + 20 1 SPARE 34 35 SPARE 1 20 + 20 1 SPARE 36 37 SPARE 1 20 + 20 1 SPARE 38 39 SPARE 1 20 + 20 1 SPARE 40 41 SPARE 1 20 + 20 1 SPARE 42 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 144 144 125% 180 B. (R) RECEPTACLES 10800 10800 NEC 220 10400 C. (LM) LARGEST MOTOR 0 0 25% 0 D. (M) MOTORS (ALL) 0 0 100% 0 E. (E) EQUIPMENT 6000 6000 100% 6000 SPECIFIC NOTES: (A) APPLIANCES 15000 15000 >6 9750 (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. PANEL TOTAL (KVA): 26.3 (2) (3) PANEL TOTAL (A): 73 (4) (5) PANEL: L1 VOLTAGE: 120/208V, 3PH, 4W MINIMUM BUS: 100 LOCATION: ELEC ROOM MAIN: 70/3 CB MOUNTING: SURFACE MINIMUM AIC: 22,000 NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B C POLE TRIP A B C TRIP POLE A B C 1 654 L PARKING GARAGE 1 20 + 20 1 L ELEVATOR 90 2 3 798 L PARKING LEVEL 1 20 + 20 1 L LEVEL 1 558 4 5 486 L EXTERIOR 1 20 + 20 1 L LEVEL 2 358 6 7 285 L WEST STAIR 1 20 + 20 1 L LEVEL 3 358 8 9 314 L EAST STAIR 1 20 + 20 1 L LEVEL 4 358 10 11 SPARE 1 20 + 20 1 SPARE 12 13 SPARE 1 20 + 20 1 SPARE 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 4259 4259 125% 5324 B. (R) RECEPTACLES 0 0 NEC 220 0 C. (LM) LARGEST MOTOR 0 0 25% 0 D. (M) MOTORS (ALL) 0 0 100% 0 E. (E) EQUIPMENT 0 0 100% 0 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 (1) PANEL TOTAL (KVA): 5.3 (2) (3) PANEL TOTAL (A): 15 (4) (5) PANEL: P3 VOLTAGE: 120/208V, 3PH, 4W MINIMUM BUS: 250 LOCATION: LVL 3 ELEC CLOSET MAIN: 250/3 CB MOUNTING: SURFACE MINIMUM AIC: 22,000 NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B C POLE TRIP A B C TRIP POLE A B C 1 720 R LEVEL 3 CORRIDOR 1 20 + 20 1 R LEVEL 4 CORRIDOR 720 2 3 360 R LEVEL 3 ELEC ROOM 1 20 + 20 1 R LEVEL 4 ELEC ROOM 360 4 5 938 E ROOF HEAT TRACE (1) 2 30 + 30 2 E ROOF HEAT TRACE (1) 938 6 7 938 E - - - + - - E - 938 8 9 1028 E ROOF HEAT TRACE (1) 2 30 + 30 2 E ROOF HEAT TRACE (1) 923 10 11 1028 E - - - + - - E - 923 12 13 1500 A LEVEL 3 - DRYER (2) 1 20 + 20 1 A LEVEL 4 - DRYER (2) 1500 14 15 1500 A LEVEL 3 - DRYER (2) 1 20 + 20 1 A LEVEL 4 - DRYER (2) 1500 16 17 1500 A LEVEL 3 - DRYER (2) 1 20 + 20 1 A LEVEL 4 - DRYER (2) 1500 18 19 1500 A LEVEL 3 - WASHER (2) 1 20 + 20 1 A LEVEL 4 - WASHER (2) 1500 20 21 1500 A LEVEL 3 - WASHER (2) 1 20 + 20 1 A LEVEL 4 - WASHER (2) 1500 22 23 1500 E LEVEL 3 - VENDING 1 20 + 20 1 E LEVEL 4 - VENDING 1500 24 25 1500 E LEVEL 3 - VENDING 1 20 + 20 1 E LEVEL 4 - VENDING 1500 26 27 180 R LEVEL 3 - LAUNDRY 1 20 + 20 1 R LEVEL 4 - LAUNDRY 180 28 29 550 R ATTIC REC/LTG 1 20 + 30 2 SPARE (1) 30 31 SPARE (1) 2 30 + - - - 32 33 - - - + 30 2 SPARE (1) 34 35 SPARE (1) 2 30 + - - - 36 37 - - - + 20 1 SPARE 38 39 SPARE 1 20 + 20 1 SPARE 40 41 SPARE 1 20 + 20 1 SPARE 42 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 0 0 125% 0 B. (R) RECEPTACLES 3070 3070 NEC 220 3070 C. (LM) LARGEST MOTOR 0 0 25% 0 D. (M) MOTORS (ALL) 0 0 100% 0 E. (E) EQUIPMENT 13654 13654 100% 13654 SPECIFIC NOTES: (A) APPLIANCES 15000 15000 >6 9750 (1) PROVIDE 30-mA GFEP CIRCUIT BREAKER. PANEL TOTAL (KVA): 26.5 (2) PROVIDE 5-mA GFCI CIRCUIT BREAKER. (3) PANEL TOTAL (A): 74 (4) (5) LOAD SUMMARY - DP1 (600 AMPS - 208 VOLTS) VOLTAGE: 208 NUMBER OF PANEL LOAD UNIT TOTAL LOAD PHASE: 3 UNITS (VA) (VA) UNIT STUDIO 17 17,599.0 299,183 STUDIO + 2 17,659.0 35,318 1BR 10 17,798.0 177,980 2BR 2 17,950.0 35,900 TOTAL NUMBER OF UNITS 31 CALCULATED RESIDENTIAL LOAD 548,381 VA DEMAND FACTOR (PER TABLE 220.84) 0.32 DEMANDED RESIDENTIAL LOAD 175,482 VA 487.1 AMPS Note: LOAD SUMMARY - DP3 (600 AMPS - 208 VOLTS) VOLTAGE: 208 NUMBER OF PANEL LOAD UNIT TOTAL LOAD PHASE: 3 UNITS (VA) (VA) UNIT STUDIO 18 17,599.0 316,782 STUDIO + 2 17,659.0 35,318 1BR 12 17,798.0 213,576 2BR 2 17,950.0 35,900 TOTAL NUMBER OF UNITS 34 CALCULATED RESIDENTIAL LOAD 601,576 VA DEMAND FACTOR (PER TABLE 220.84) 0.30 DEMANDED RESIDENTIAL LOAD 180,473 VA 500.9 AMPS Note: PANEL: DP3 VOLTAGE: 120/208V, 3PH, 4W MINIMUM BUS: 600 LOCATION: LVL 3 ELEC CLOSET MAIN: 600/3 CB MOUNTING: SURFACE MINIMUM AIC: 42,000 NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B C POLE TRIP A B C TRIP POLE A B C 1 UNIT 301 STUDIO 2 100 + 100 2 UNIT 401 STUDIO 2 3 - - - + - - - 4 5 UNIT 302 ONE BR 2 100 + 100 2 UNIT 402 ONE BR 6 7 - - - + - - - 8 9 UNIT 303 ONE BR 2 100 + 100 2 UNIT 403 ONE BR 10 11 - - - + - - - 12 13 UNIT 304 TWO BR 2 100 + 100 2 UNIT 404 TWO BR 14 15 - - - + - - - 16 17 UNIT 305 STUDIO 2 100 + 100 2 UNIT 405 STUDIO 18 19 - - - + - - - 20 21 UNIT 306 STUDIO 2 100 + 100 2 UNIT 406 STUDIO 22 23 - - - + - - - 24 25 UNIT 307 STUDIO 2 100 + 100 2 UNIT 407 STUDIO 26 27 - - - + - - - 28 29 UNIT 308 STUDIO 2 100 + 100 2 UNIT 408 STUDIO 30 31 - - - + - - - 32 33 UNIT 309 STUDIO + 2 100 + 100 2 UNIT 409 STUDIO + 34 35 - - - + - - - 36 37 UNIT 310 ONE BR 2 100 + 100 2 UNIT 410 ONE BR 38 39 - - - + - - - 40 41 UNIT 311 ONE BR 2 100 + 100 2 UNIT 411 ONE BR 42 43 - - - + - - - 44 45 UNIT 312 STUDIO 2 100 + 100 2 UNIT 412 STUDIO 46 47 - - - + - - - 48 49 UNIT 313 STUDIO 2 100 + 100 2 UNIT 413 STUDIO 50 51 - - - + - - - 52 53 UNIT 314 STUDIO 2 100 + 100 2 UNIT 414 STUDIO 54 55 - - - + - - - 56 57 UNIT 315 STUDIO 2 100 + 100 2 UNIT 415 STUDIO 58 59 - - - + - - - 60 61 UNIT 316 ONE BR 2 100 + 100 2 UNIT 416 ONE BR 62 63 - - - + - - - 64 65 UNIT 317 ONE BR 2 100 + 100 2 UNIT 417 ONE BR 66 67 - - - + - - - 68 69 SPARE 2 100 + 100 2 SPARE 70 71 - - - + - - - 72 73 SPARE 2 100 + 100 2 SPARE 74 75 - - - + - - - 76 77 SPARE 2 100 + 100 2 SPARE 78 79 - - - + - - - 80 81 SPARE 2 100 + 100 2 SPARE 82 83 - - - + - - - 84 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 0 0 125% 0 B. (R) RECEPTACLES 0 0 NEC 220 0 C. (LM) LARGEST MOTOR 0 0 25% 0 D. (M) MOTORS (ALL) 0 0 100% 0 E. (E) EQUIPMENT 0 0 100% 0 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 (1) PANEL TOTAL (KVA): 180.5 (2) REFER TO 'LOAD SUMMARY - DP3' ON THIS SHEET FOR MORE INFORMATION. (3) PANEL TOTAL (A): 501 (4) (5) PANEL: DP1 VOLTAGE: 120/208V, 3PH, 4W MINIMUM BUS: 600 LOCATION: ELEC ROOM MAIN: MLO MOUNTING: SURFACE MINIMUM AIC: 65,000 NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B C POLE TRIP A B C TRIP POLE A B C 1 UNIT 101 STUDIO 2 100 + 100 2 UNIT 201 STUDIO 2 3 - - - + - - - 4 5 UNIT 102 ONE BR 2 100 + 100 2 UNIT 202 ONE BR 6 7 - - - + - - - 8 9 UNIT 103 ONE BR 2 100 + 100 2 UNIT 203 ONE BR 10 11 - - - + - - - 12 13 UNIT 104 TWO BR 2 100 + 100 2 UNIT 204 TWO BR 14 15 - - - + - - - 16 17 UNIT 105 STUDIO 2 100 + 100 2 UNIT 205 STUDIO 18 19 - - - + - - - 20 21 UNIT 106 STUDIO 2 100 + 100 2 UNIT 206 STUDIO 22 23 - - - + - - - 24 25 UNIT 107 STUDIO 2 100 + 100 2 UNIT 207 STUDIO 26 27 - - - + - - - 28 29 UNIT 108 ADA STUDIO + 2 100 + 100 2 UNIT 208 STUDIO 30 31 - - - + - - - 32 33 UNIT 109 ONE BR 2 100 + 100 2 UNIT 209 STUDIO + 34 35 - - - + - - - 36 37 UNIT 110 STUDIO 2 100 + 100 2 UNIT 210 ADA ONE BR 38 39 - - - + - - - 40 41 UNIT 111 STUDIO 2 100 + 100 2 UNIT 211 ONE BR 42 43 - - - + - - - 44 45 UNIT 112 STUDIO 2 100 + 100 2 UNIT 212 STUDIO 46 47 - - - + - - - 48 49 UNIT 113 STUDIO 2 100 + 100 2 UNIT 213 STUDIO 50 51 - - - + - - - 52 53 UNIT 114 ONE BR 2 100 + 100 2 UNIT 214 STUDIO 54 55 - - - + - - - 56 57 SPARE 2 100 + 100 2 UNIT 215 STUDIO 58 59 - - - + - - - 60 61 SPARE 2 100 + 100 2 UNIT 216 ONE BR 62 63 - - - + - - - 64 65 SPARE 2 100 + 100 2 UNIT 217 ONE BR 66 67 - - - + - - - 68 69 SPARE 2 100 + 100 2 SPARE 70 71 - - - + - - - 72 73 SPARE 2 100 + 100 2 SPARE 74 75 - - - + - - - 76 77 SPARE 2 100 + 100 2 SPARE 78 79 - - - + - - - 80 81 SPARE 2 100 + 100 2 SPARE 82 83 - - - + - - - 84 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 0 0 125% 0 B. (R) RECEPTACLES 0 0 NEC 220 0 C. (LM) LARGEST MOTOR 0 0 25% 0 D. (M) MOTORS (ALL) 0 0 100% 0 E. (E) EQUIPMENT 0 0 100% 0 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 (1) PANEL TOTAL (KVA): 175.5 (2) REFER TO 'LOAD SUMMARY - DP1' ON THIS SHEET FOR MORE INFORMATION. (3) PANEL TOTAL (A): 487 (4) (5) Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-002 ELECTRICAL SCHEDULES 09/21/18 UP(22R) FIRE EXCAB FIRE EXCAB 5 UP UP UP DN T 1. UTILITY TRANSFORMER. 2. REFER TO ELECTRICAL ONE-LINE DIAGRAM ON SHEET E-400 FOR FEEDER SIZE. 3. ELECTRICAL SERVICE ENTRANCE EQUIPMENT LOCATED IN THIS ROOM. 4. BOLLARDS SHALL BE CONTROLLED VIA EXTERIOR LIGHTING CONTROL PANEL WITH ASTRONOMIC TIME CLOCK AND PHOTOCELL. 5. GENERATOR LOCATED UNDER THIS PORTION OF THE BUILDING. PROVIDE WEATHERPROOF DUPLEX RECEPTACLE AT GENERATOR. CIRCUIT RECEPTACLE TO P1-32. SCALE: 1 ELECTRICAL SITE PLAN 1/16" = 1'-0" 4 E2 P1-30 4 E2P1-30 4 E2 P1-30 20A(2WG) (3)4"C. VOICE/DATA PEDESTAL CATV PEDESTAL 1 4 E2 4E2 4E2 4 E2 4E2 4E2 4E2 4E2 FLAG NOTES:X 5 4 E2 3 2 20A(2WG) P1-30 P1-30 P1-30 P1-30 P1-30 P1-30 P1-30 P1-30 P1-30 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL SITE PLAN E-100 09/21/18 UP (22R) FIRE EXCAB FIRE EXCAB UP UP 18/2 18/2 29 1 K J F E D B A 9 10 2 4 6 12 15 16 17 18 19 20 21 22 YF Y YH YL YJ YM 16 17 18 19 20 21 22 YK YE YD 7 5 1 2 L M 3 7 6 9 10 G H SCALE: ELECTRICAL PLAN - PARKING LEVELS 1/8" = 1'-0" +48" +48" +48" +48" +48" WP WP WP G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 G1 E1 E1 OS J P1-2 J S4S S4 S4 S4S4 S4S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S4 S+48" +48" +48" +48" +48" +48" +48" +48" +48" +48"SS OS OS OS S S OS OS WP 'SWB' S3 S3 S3 S3 S3 E1 E1 E1 E1 E1 E1 G1 G1 G1 G1 G1 G1 P1-1 P1-1 P1-1 P1-1 P1-3 P1-3 P1-3 P1-3 P1-3 P1-3 P1-3 P1-3 P1-3 P1-5 P1-5 P1-5 P1-5 SOP1-5 P1-7 P1-7 P1-7 P1-7 P1-9 P1-11 P1-13 P1-13 P1-13 P1-13 OS OS SK S K OS SK S1 S5 P1-15 L1-1 L1-1 L1-1 L1-1 L1-1 L1-3 L1-3 L1-3 L1-3 L1-5 L1-5 L1-5 L1-5 L1-2 L1-7 L1-9 'M1' 'P1' 'L1' 'ATS-E' 'ATS-S' 1. ALL LIGHTING ON THIS SHEET IS ON EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. 2. ALL EXIT SIGNS SHALL BE CIRCUITED TO LOCAL LIGHTING CIRCUIT. NOTES: 1. RECEPTACLE MOUNTED IN ELEVATOR PIT. 2. LIGHT MOUNTED IN ELEVATOR PIT. 3. PROVIDE 20A, 120V ELECTRICAL FEED TO JUNCTION BOX FOR MOTORIZED GARAGE DOOR. GARAGE DOOR SHALL BE CONTROLLED VIA KEYPAD FOR ENTRY AND MOTION DETECTOR FOR EXIT. COORDINATE EXACT POWER REQUIREMENTS AND CONTROLS WITH GARAGE DOOR REVIEWED SUBMITTAL PRIOR TO ROUGH-IN. COORDINATE EXACT LOCATION OF CONTROLS WITH GENERAL CONTRACTOR AND ARCHITECT PRIOR TO ROUGH-IN. 4. PROVIDE 1" CONDUIT WITH PULL STRING FROM THIS LOCATION TO 'ELEC ROOM' ON THIS LEVEL FOR ELECTRIC UTILITY METER REPEATER. ELECTRICAL CONTRACTOR SHALL PROVIDE SELF-ADHESIVE PRINTED LABEL INDICATING CONDUIT IS TO BE USED BY ELECTRIC UTILITY ONLY. 5. PUSH BUTTON TO CONTROL SHUNT TRIP DISCONNECT IN 'ELEC ROOM'. PROVIDE PROTECTIVE COVER TO PREVENT ACCIDENTAL PRESSING. PUSH BUTTON SHALL BE CLEARLY LABELED AS THE MAIN DISCONNECT. 6. ALL EXTERIOR LIGHTS SHALL BE CONTROLLED VIA EXTERIOR LIGHTING CONTROL PANEL WITH ASTRONOMIC TIME CLOCK AND PHOTOCELL. 7. SURFACE MOUNT CCTV CAMERA - IP MEGAPIXEL DOME. 8. PROVIDE EMERGENCY SHUT-OFF PUSH BUTTON FOR GENERATOR IN THIS LOCATION. PROVIDE PROTECTIVE COVER TO PREVENT ACCIDENTAL PRESSING. PUSH BUTTON SHALL BE CLEARLY LABELED AS THE DISCONNECT FOR THE GENERATOR. 9. PROVIDE 1" CONDUIT WITH PULL STRING TO THIS LOCATION FROM GARAGE DOOR CONTROLLER/MOTOR. RE: FLAG NOTE #3 ON THIS SHEET FOR MORE INFORMATION. 10. PROVIDE ACUITY WSD PDT DUAL-TECHNOLOGY, 1-POLE WALL SENSOR SWITCH OR EQUIVALENT. 11. PROVIDE ACUITY CMR-PDT-10-2P DUAL-TECHNOLOGY, 2-POLE WALL, CEILING MOUNT, OCCUPANCY SENSOR OR EQUIVALENT. FLAG NOTES:# 1 2 3 J 4 5 8 6 6 6 7 7 9 11 10 11 11 11 11 11 11 11 7 7 7 P 6 P 1 P 2 P 2 P 2 P 3P 3 P 4 P 5 P 1 EF 4 EF 3 EF 2 EF 1 EF 5 EF 2 EF 2 CUH 1 UH 1 UH 1 UH 1 UH 1 UH 1 UH 1 UH 1 UH 1 B 1 B 1 B 1 WH 1 WH 1 UH 1 UH 1 UH 1 CUH 3 CUH 4 UH 1 M1-11,13 M1-15,17 M1-19,21,23 M1-25,27,29 M1-31,33,35 GF 1 M1-14 M1-14 M1-14 M1-14 M1-14 M1-14 M1-14 M1-14 M1-16 M1-16 M1-16 M1-16 M1-18 M1-20 M1-20 M1-20 M1-20 X1 X1 +48"P1-1 P1-1 X1 X1X1 X1 L1-5 6 X1 1 1 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH31 AUG. 2018 PERMIT RESPONSES ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - PARKING LEVELS E-201 09/21/18 SCALE: ELECTRICAL PLAN - LEVEL 1 1/8" = 1'-0" UP DN UP DN DN D/W 1 K J F E D B A 8 10 2 4 6 12 15 16 17 18 19 20 21 22 YB YA YC YD YF YG YH YL YJ YM 16 17 18 19 20 21 22 YK YE YD 7 5 1 2 L M 3 7 6 8 10 G H D/W D/WD/WD OS SOSK SK SK S3 S3 S3 S3 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 R1 E1 E1 X1 X1 X1 X1 X1 X1 S1 S1 S OS S1 SO S4 X1 P1-2 P1-2 P1-2 P1-2 P1-4 P1-4 P1-4 P1-4 P1-6 P1-8 P1-8 P1-8 P1-8 L1-5 L1-5 L1-7 L1-9 L1-4 L1-4 L1-4 L1-4 L1-4 1. ALL LIGHTING ON THIS SHEET IS ON EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. 2. ALL EXIT SIGNS SHALL BE CIRCUITED TO LOCAL LIGHTING CIRCUIT. NOTES: 1. ALL EXTERIOR LIGHTS SHALL BE CONTROLLED VIA EXTERIOR LIGHTING CONTROL PANEL WITH ASTRONOMIC TIME CLOCK AND PHOTOCELL. 2. SURFACE MOUNT CCTV CAMERA - IP MEGAPIXEL DOME. 3. WIRELESS ACCESS POINT (WI-FI). MOUNT 2-PORT BISCUIT JACK ABOVE CEILING. PROVIDE ACCESS PANEL AS REQUIRED. 4. GENERATOR ANNUNCIATOR PANEL. 5. PROVIDE ACUITY CMR-PDT-10-2P DUAL-TECHNOLOGY, 2-POLE, CEILING MOUNT, OCCUPANCY SENSOR OR EQUIVALENT. 6. PROVIDE ACUITY WSD PDT DUAL-TECHNOLOGY, 1-POLE WALL SENSOR SWITCH OR EQUIVALENT. 7. RE: DIAGRAM 2/E-402 FOR MDF INFORMATION. FLAG NOTES:# 1 1 2 180 2 3 3 3 3 3 3 ANN4 5 5 6 6 7 P1-27 P1-29 P1-17 P1-19 P1-21P1-23P1-25P1-31WP P1-13 WP P1-13 WP P1-13 X1 1 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH31 AUG. 2018 PERMIT RESPONSES ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELETRICAL PLAN - LEVEL 1 E-202 09/21/18 SCALE: ELECTRICAL PLAN - LEVEL 2 1/8" = 1'-0" UP DN UP DN D/W 1 K J F E D B A 8 10 2 4 6 12 15 16 17 18 19 20 21 22 YB YA YC YD YF YG YH YL YJ YM 16 17 18 19 20 21 22 YK YE YD 7 5 1 2 L M 3 7 6 8 10 G H D/W D/WD/WSKSK SK S3 S3 S3 S3 S OS X1 X1 X1 X1 X1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S4 SO P1-10 P1-10 P1-10 P1-10 P1-12 L1-7 L1-9 L1-6 L1-6 L1-6 1. ALL LIGHTING ON THIS SHEET IS ON EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. 2. ALL EXIT SIGNS SHALL BE CIRCUITED TO LOCAL LIGHTING CIRCUIT. NOTES: 1. WIRELESS ACCESS POINT (WI-FI). MOUNT 2-PORT BISCUIT JACK ABOVE CEILING. PROVIDE ACCESS PANEL AS REQUIRED. 2. PROVIDE ACUITY CMR-PDT-10-2P DUAL-TECHNOLOGY, 2-POLE, CEILING MOUNT, OCCUPANCY SENSOR OR EQUIVALENT. 3. PROVIDE ACUITY WSD PDT DUAL-TECHNOLOGY, 1-POLE WALL SENSOR SWITCH OR EQUIVALENT. FLAG NOTES:# 2 3 1 1 1 1 1 1 P1-24 P1-26 P1-14 P1-16 P1-18P1-20P1-22P1-28Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - LEVEL 2 E-203 09/21/18 SCALE: ELECTRICAL PLAN - LEVEL 3 1/8" = 1'-0" UP DN UP DN D/W 1 K J F E D B A 8 10 2 4 6 12 15 16 17 18 19 20 21 22 YB YA YC YD YF YG YH YL YJ YM 16 17 18 19 20 21 22 YK YE YD 7 5 1 2 L M 3 7 6 8 10 G H D/W D/W D/WD/WS3 S3 S3 S3 SK SK X1 X1 X1 X1 X1 SO S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S4 S OS 'DP3' P3-1 P3-3 P3-1 P3-1 P3-1 L1-7 L1-9 L1-8 L1-8 L1-8SK'P3' 1. ALL LIGHTING ON THIS SHEET IS ON EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. 2. ALL EXIT SIGNS SHALL BE CIRCUITED TO LOCAL LIGHTING CIRCUIT. NOTES: 1. WIRELESS ACCESS POINT (WI-FI). MOUNT 2-PORT BISCUIT JACK ABOVE CEILING. PROVIDE ACCESS PANEL AS REQUIRED. 2. PROVIDE ACUITY CMR-PDT-10-2P DUAL-TECHNOLOGY, 2-POLE, CEILING MOUNT, OCCUPANCY SENSOR OR EQUIVALENT. 3. PROVIDE ACUITY WSD PDT DUAL-TECHNOLOGY, 1-POLE WALL SENSOR SWITCH OR EQUIVALENT. FLAG NOTES:# 2 3 1 1 1 1 1 1 P3-23 P3-25 P3-13 P3-15 P3-17P3-19P3-21P3-27Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - LEVEL 3 E-204 09/21/18 SCALE: ELECTRICAL PLAN - LEVEL 4 1/8" = 1'-0" DN H GF DN 1 K J F E D B A 8 10 2 4 6 12 15 16 17 18 19 20 21 22 YB YA YC YD YF YG YH YL YJ YM 16 17 18 19 20 21 22 YK YE YD 7 5 1 2 L M 3 7 6 8 10 G H D/W D/W D/W D/WD/WSS3 S3 S3 S3 SK SK X1 X1 X1 X1 X1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S1 S4 SOS OS S5 P1-15 P3-2 P3-2 P3-2 P3-2 P3-4 L1-2 L1-7 L1-9 SKL1-10 L1-10L1-10 1. ALL LIGHTING ON THIS SHEET IS ON EMERGENCY GENERATOR UNLESS NOTED OTHERWISE. 2. ALL EXIT SIGNS SHALL BE CIRCUITED TO LOCAL LIGHTING CIRCUIT. NOTES: 1. WIRELESS ACCESS POINT (WI-FI). MOUNT 2-PORT BISCUIT JACK ABOVE CEILING. PROVIDE ACCESS PANEL AS REQUIRED. 2. PROVIDE ACUITY CMR-PDT-10-2P DUAL-TECHNOLOGY, 2-POLE, CEILING MOUNT, OCCUPANCY SENSOR OR EQUIVALENT. 3. PROVIDE ACUITY WSD PDT DUAL-TECHNOLOGY, 1-POLE WALL SENSOR SWITCH OR EQUIVALENT. 4. RECEPTACLE MOUNTED IN TOP OF ELEVATOR SHAFT. 5. LIGHT MOUNTED IN TOP OF ELEVATOR SHAFT. FLAG NOTES:# 4 5 3 4 1 1 1 1 1 1 P3-24 P3-26 P3-14 P3-16 P3-18P3-20P3-22P3-28Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - LEVEL 4 E-205 09/21/18 1 K J F E D B A 9 10 2 4 6 12 15 16 17 18 19 20 21 22 Y YF YG YH YL YJ YM 16 17 18 19 20 21 22 YK YE YD 7 5 1 2 L M 3 7 6 9 10 G H SCALE: ELETRICAL PLAN - ROOF 1/8" = 1'-0" 1. PROVIDE 12W/FT, 208 VOLT ELECTRICAL, SELF REGULATING, HEATING CABLE IN ALL GUTTERS AND DOWNSPOUTS. ELECTRIC HEATING CABLE SHALL BE UL AND CSA LISTED SPECIFICALLY AS ELECTRIC ROOF AND GUTTER DE-ICING AND SNOWMELTING EQUIPMENT. CABLE BE QUALIFIED FOR PROLONGED UV EXPOSURE TO THE SUN PER IEEE 515-1997 AND TO WITHSTAND CONTINUOUS SUBMERSION IN WATER PER IEEE 515.1-1997. PROVIDE ALL ELECTRICAL CONNECTION KITS, SUPPORTS, DOWNSPOUT HANGERS, CONTROLS, AND OTHER APPERTENANCES FOR A COMPLETE AND OPERABLE SYSTEM IN COMPLIANCE WITH MANUFACTURER'S RECOMENDATIONS. 2. OVERCURRENT PROTECTION FOR ELECTRIC HEATING CABLE CIRCUITS SHALL BE 30-mA-TRIP GROUND FAULT TYPE CIRCUIT BREAKERS. 3. PROVIDE ELECTRIC HEATING CABLE IN DRAINAGE VALLEYS, AS SHOWN ON PLAN. ROUTE ELECTRIC HEATING CABLE A MINIMUM OF 8” INTO ROOF DRAIN. 4. CONTRACTOR SHALL PROVIDE COMPLETE AND OPERABLE CONTROL SYSTEM. SYSTEM SHALL CONSIST OF AMBIENT THERMOSTAT AND MOISTURE SENSOR WITH CONTACTOR(S). 5. CONTRACTOR SHALL SUBMIT SHOP DRAWING SUBMITTAL WITH ALL EQUIPMENT, CONTROLS, CONTACTORS AND ACCESSORY DATA SHEETS. DATA SHEETS SHALL BE MARKED INDICATING THE ACTUAL MODEL, VOLTAGE, RATINGS, AND ACCESSORIES BEING PROPOSED TO BE PROVIDED. SHOP DRAWING SHALL INCLUDE LAYOUT PLAN INDICATING ZONING, CONTROL INTENT, AND ESTIMATED CIRCUIT LENGHTS. PARTIAL OR INCOMPLETE SUBMITTALS WILL NOT BE ACCEPTED. 6. ACTUAL INSTALLED HEAT TRACE CIRCUIT LENGTH MAY VARY FROM DESIGN OR PLANNED FOR CIRCUIT LENGTHS. CONTRACTOR SHALL MEASURE AND RECORD ACTUAL CIRCUIT LENGTHS AND PROVIDE THE CIRCUIT LENGTHS AS PART OF TEST REPORTS. CIRCUIT LENGTH SHALL NOT EXCEED THE MANUFACTURER'S RECOMMENDED LENGTH FOR THE OVERCURRENT PROTECTION RATING. CONTACT ARCHITECT/ENGINEER IF ACTUAL INSTALLED ELECTRIC HEATING CABLE LENGTHS EXCEED THE MANUFACTURER'S RECOMMENDED LENGTH FOR THE OVERCURRENT PROTECTION RATING. 7. CONTRACTOR SHALL PROVIDE ALL TESTING AND FIELD QUALITY CONTROL MEASURES RECOMMENDED BY MANUFACTER. INCLUDING, BUT NOT LIMITED TO, MEGER TEST ALL ELECTRIC HEATING CABLE CIRCUITS. AFTER INSTALLATION ALL HEATING CABLE CIRCUITS SHALL BE TESTED WITH A 2500 VDC MEGOHMMETER, INSULATION RESISTANCE FROM THE CONDUCTORS TO THE SHIELD SHALL BE GREATER THAN 1000 MEGOHMS. CONTRACTOR SHALL RECORD ALL TESTS AND PROVIDE TEST REPORTS TO ARCHITECT/ENGINEER, PRIOR TO PROJECT CLOSEOUT OR FINAL PUNCH REQUESTS, AS PART OF THE PROJECT CLOSEOUT DOCUMENTS. ROOF HEAT TRACE NOTES: J J J J 1 1 1 1 1. PROVIDE 30A, 208V ELECTRICAL CIRCUIT TO WEATHERPROOF JUNCTION BOX FOR ROOF HEAT TRACE. REFER TO ROOF HEAT TRACE NOTES ON THIS SHEET FOR MORE INFORMATION. 2. PROVIDE (1) RUN OF 12W/FT, SELF-REGULATING HEATING CABLE IN GUTTER AND (1) RUN OF 12W/FT, SELF-REGULATING HEATING CABLE IN DOWNSPOUT. REFER TO ROOF HEAT TRACE NOTES ON THIS SHEET FOR MORE INFORMATION. 3. MECHANICAL EQUIPMENT LOCATED IN ATTIC SPACE. 4. LOCATE SWITCH AT HATCH TO ATTIC SPACE. 5. LIGHT FIXTURES SHALL BE LOCATED IN ATTIC SPACE. 6. LOCATE JUNCTION BOX IN ATTIC SPACE FOR FUTURE HEAT TRACE. PROVIDE 1" CONDUIT FROM PANEL 'P3' TO JUNCTION BOX FOR FUTURE HEAT TRACE CONDUCTORS. ELECTRICAL CONTRACTOR SHALL CLEARLY LABEL JUNCTION BOX WITH SELF-ADHESIVE PRINTED LABEL INDICATING JUNCTION BOX IS FOR FUTURE HEAT TRACE CONNECTION. 7. PROVIDE (1) RUN OF 12W/FT, SELF-REGULATING HEATING CABLE IN GUTTER AND (1) RUN OF 12W/FT, SELF-REGULATING HEATING CABLE IN DOWNSPOUT. EXTEND HEATING CABLE 5 FEET INTO STORM DRAIN. REFER TO ROOF HEAT TRACE NOTES ON THIS SHEET FOR MORE INFORMATION. FLAG NOTES:# 7 7 2 2 P3-5,7 P3-9,11 P3-6,8 P3-10,12 MAU 1 MAU 2 EF 6 EF 6 EF 6 EF 6 EF 6 EF 6 EF 6 EF 6 EF 6 EF 6 3 3 3 S4 S4 S4 S4 S4 S 4 5 5 5 5 5 P3-29 P3-29 P3-29 J J J J 6 6 6 6 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - ROOF E-206 09/21/18 SCALE: 1 ELECTRICAL PLAN - TYPE STUDIO ( NO SHAFT) @ LEVELS 1-4 1/2"= 1'-0" S1 S1 S2 S1 S1 S1 S1 SSS SS REF 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. MOUNT RECEPTACLE WITHIN 10" OF TOP OF COUNTERTOP. 5. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: 1 C DISP S2 3 4 C S +72" RANGE MW TV DW1 5 'UNIT LOAD CENTER' EF 1 1 3 5,7 9 11 2 13 6 6 6 8 6 8 8 8 8 6 10 10 10 12 1212 14 UNIT TYPE: STUDIO (NO SHAFT) @ LEVELS 1-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1080 6 7 4500 A - - - + 20 1 R REC 900 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 360 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - STUDIO 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 448 3 = 1344 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4344 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 470 VA Over 120,000VA 25% = 0 VA 3470.4 VA x 100% = 3470 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 19517 VA TOTAL DEMAND ELECTRICAL LOAD: 17149 VA MINIMUM ELECTRICAL SERVICE SIZE: 82.4 AMPS C 4 C 13 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - STUDIO E-301 09/21/18 SCALE: 1 ELECTRICAL PLAN - TYPE STUDIO (NO SHAST) OPP HAND @ LEVELS 1-4 1/2"= 1'-0" S2 S1 S1 S S S1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. MOUNT RECEPTACLE WITHIN 10" OF TOP OF COUNTERTOP. 5. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# S1 REF 1 C DISP S2 3 4 C S RANGE +72" MW DW 1 TV 5 'UNIT LOAD CENTER' EF 1 S1 S1 S1 SS 1 3 5,7 9 11 13 13 6 6 6 6 6 8 8 8 8 8 10 10 10 12 12 12 14 UNIT TYPE: STUDIO (NO SHAFT) OPP HAND @ LEVELS 1-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1080 6 7 4500 A - - - + 20 1 R REC 900 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 360 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - STUDIO 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 449 3 = 1347 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4347 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 471 VA Over 120,000VA 25% = 0 VA 3471.45 VA x 100% = 3471 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 19520 VA TOTAL DEMAND ELECTRICAL LOAD: 17150 VA MINIMUM ELECTRICAL SERVICE SIZE: 82.5 AMPS C 2 C 4 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - STUDIO E-302 09/21/18 SCALE: 1 ELECTRICAL PLAN - STUDIO x01 @ LEVELS 1-4 1/2"= 1'-0" S2 S1 S1 SS S S1 REF 1 C DISPS 2 3 4 C S 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. MOUNT RECEPTACLE WITHIN 10" OF TOP OF COUNTERTOP. 5. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# RANGE MW +72" DW 1 TV 'UNIT LOAD CENTER' 5 EF 1 S1 S1 S1 SS 1 3 5,7 9 11 13 13 6 6 6 6 6 8 8 8 8 8 10 10 10 12 12 14 12 UNIT TYPE: STUDIO x01 @ LEVELS 1-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1080 6 7 4500 A - - - + 20 1 R REC 900 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 360 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) DC 1 18 N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - STUDIO 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 450 3 = 1350 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4350 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 473 VA Over 120,000VA 25% = 0 VA 3472.5 VA x 100% = 3473 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 19523 VA TOTAL DEMAND ELECTRICAL LOAD: 17152 VA MINIMUM ELECTRICAL SERVICE SIZE: 82.5 AMPS C 2 C 4 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - STUDIO E-303 09/21/18 SCALE: 1 ELECTRICAL PLAN - STUDIO x07 @ LEVELS 1-4 1/2"= 1'-0" S2 S1 S1 SS S 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. MOUNT RECEPTACLE WITHIN 10" OF TOP OF COUNTERTOP. 5. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES: S1 REF 1 C DISP S2 3 4 C S RANGE +72" MW DW 1 TV 5 'UNIT LOAD CENTER' EF 1S1 S1 S1 SS 1 3 5,7 9 11 13 13 6 6 6 6 6 8 8 8 8 8 10 10 10 12 12 12 14 UNIT TYPE: STUDIO x07 @ LEVELS 1-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1080 6 7 4500 A - - - + 20 1 R REC 900 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 360 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - STUDIO 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 449 3 = 1347 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4347 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 471 VA Over 120,000VA 25% = 0 VA 3471.45 VA x 100% = 3471 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 19520 VA TOTAL DEMAND ELECTRICAL LOAD: 17150 VA MINIMUM ELECTRICAL SERVICE SIZE: 82.5 AMPS C 2 C 4 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: # Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - STUDIO E-304 09/21/18 SCALE: 1 ELECTRICAL PLAN - STUDIO x08 @ LEVELS 1-4 1/2"= 1'-0" S2 S1 S1 S SS 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. MOUNT RECEPTACLE WITHIN 10" OF TOP OF COUNTERTOP. 5. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# S1 REF 1 C DISP S2 3 4 C S RANGE +72" MW DW 1 TV 5 'UNIT LOAD CENTER' HRV 1 S1 S1 S1 SS 1 3 5,7 9 11 1313 6 6 6 6 6 8 8 8 8 8 12 12 10 10 10 16 12 UNIT TYPE: STUDIO x08 @ LEVELS 1-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1080 6 7 4500 A - - - + 20 1 R REC 900 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 360 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - STUDIO 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 449 3 = 1347 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4347 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 471 VA Over 120,000VA 25% = 0 VA 3471.45 VA x 100% = 3471 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 19520 VA TOTAL DEMAND ELECTRICAL LOAD: 17150 VA MINIMUM ELECTRICAL SERVICE SIZE: 82.5 AMPS C 2 C 4 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - STUDIO E-305 09/21/18 SCALE: 1 ELECTRICAL PLAN - TYPE STUDIO + x09 UNITS @ LEVELS 1-4 1/2"= 1'-0" 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# UNIT TYPE: STUDIO + x09 @ LEVELS 1-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1080 6 7 4500 A - - - + 20 1 R REC 900 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 SPARE 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPACE + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - STUDIO 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 504 3 = 1512 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4512 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 529 VA Over 120,000VA 25% = 0 VA 3529.2 VA x 100% = 3529 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 19685 VA TOTAL DEMAND ELECTRICAL LOAD: 17208 VA MINIMUM ELECTRICAL SERVICE SIZE: 82.7 AMPS 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES:S SSSS S1 S1 S1 S1 S2 S1 S1 REF 1 2 DISP S3 4 C S C RANGE MW +72" DW 1 TV 5 'UNIT LOAD CENTER' EF 1 1 3 5,7 9 11 13 13 6 6 6 6 68 8 8 8 8 10 10 10 12 12 12 14 C 2 C 4 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - STUDIO E-306 09/21/18 MAX.SCALE: 1 ELECTRICAL PLAN - ACCESSIBLE STUDIO + @ LEVEL 1 1/2"= 1'-0"SSS S S S1 S1 S1 S1 S2 S1 S1 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. MOUNT RECEPTACLE WITHIN 10" OF TOP OF COUNTERTOP. 5. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# REF 1 2 DISP S3 4 C S C RANGE MW +72" DW 1 TV 5 'UNIT LOAD CENTER' EF 1 1 3 5,7 9 11 13 13 6 6 6 6 68 8 8 8 8 10 10 10 12 12 12 14 UNIT TYPE: ADA STUDIO + VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1080 6 7 4500 A - - - + 20 1 R REC 900 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 360 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - STUDIO + 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 505 3 = 1515 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4515 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 530 VA Over 120,000VA 25% = 0 VA 3530.25 VA x 100% = 3530 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 19688 VA TOTAL DEMAND ELECTRICAL LOAD: 17209 VA MINIMUM ELECTRICAL SERVICE SIZE: 82.7 AMPS C 2 C 4 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - STUDIO E-307 09/21/18 D/WSCALE: 1 ELECTRICAL PLAN - ONE BR x02 @ LEVELS 1-4 1/2"= 1'-0"SSS1 S2 S1 S1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. MOUNT RECEPTACLE WITHIN 10" OF TOP OF COUNTERTOP. 5. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# 5 'UNIT LOAD CENTER'SS1 6 8 8 14 12 10 UNIT TYPE: ONE BR x02 @ LEVELS 1-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1620 6 7 4500 A - - - + 20 1 R REC 1620 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 360 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - STUDIO + 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 635 3 = 1905 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4905 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 667 VA Over 120,000VA 25% = 0 VA 3666.75 VA x 100% = 3667 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 20078 VA TOTAL DEMAND ELECTRICAL LOAD: 17346 VA MINIMUM ELECTRICAL SERVICE SIZE: 83.4 AMPS 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: SS S1 S1 DW DISP SCC C REF+72" MW RANGE 1 1 3 2 TV TV EF 1 1 3 5,7 9 11 2 4 6 6 4 66 6 6 6 8 88 10 10 12 C13 S1 C13 8 8 8 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - STUDIO E-308 09/21/18 D/WSCALE: 1 ELECTRICAL PLAN - ONE BR x03 @ LEVELS 1-4 1/2"= 1'-0" S SSSSS1 S2 S1 S1 S1 S1 S1 DWDISP SC C C REF +72" MW RANGE 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# 1 13 2 C S TV TV 4 'UNIT LOAD CENTER' EF 1 1 3 5,7 9 1124 6 6 6 4 6 66 6 6 6 8 8 88 8 8 8 10 10 10 10 12 12 12 14 UNIT TYPE: ONE BR x03 @ LEVELS 1-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1800 6 7 4500 A - - - + 20 1 R REC 1620 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 540 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - 1BR 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 637 3 = 1911 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4911 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 669 VA Over 120,000VA 25% = 0 VA 3668.85 VA x 100% = 3669 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 20084 VA TOTAL DEMAND ELECTRICAL LOAD: 17348 VA MINIMUM ELECTRICAL SERVICE SIZE: 83.4 AMPS C13 13 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: 8 C13 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title ELECTRICAL PLAN - 1 BR E-309 09/21/18 D/WSCALE: 1 ELECTRICAL PLAN - ONE BR - UNITS 310 & 410 1/2"= 1'-0" S SS SSSS1 S2 S1 S1 S1 S1 S1 S1 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# DW DISP SCC C REF+72" MW RANGE 1 1 3 2 CSTV TV 4 'UNIT LOAD CENTER' EF 1 1 3 5,7 911 2 4 4 6 6 6 6 6 6 6 6 88 8 8 88 8 10 10 10 10 10 12 1214 12 UNIT TYPE: ONE BR - UNITS 310 & 410 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1620 6 7 4500 A - - - + 20 1 R REC 1440 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 120 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 540 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - 1BR 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 654 3 = 1962 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4962 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 687 VA Over 120,000VA 25% = 0 VA 3686.7 VA x 100% = 3687 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 20135 VA TOTAL DEMAND ELECTRICAL LOAD: 17366 VA MINIMUM ELECTRICAL SERVICE SIZE: 83.5 AMPS C13 13 8 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: C13 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-310 ELECTRICAL PLAN - 1 BR 09/21/18 D/WSCALE: 1 ELECTRICAL PLAN - TYP ONE BR @ LEVELS 1-4 1/2"= 1'-0" SSSSS SS1 S2 S1 S1 S1 S1 S1 S1 DWDISP SC C C REF +72" MW RANGE 1 13 2 C 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:#STV TV 4 'UNIT LOAD CENTER' HRV 1 1 3 5,7 9 1124 4 6 6 6 6 66 6 88 8 8 8 8 8 8 10 10 10 10 10 12 12 14 12 UNIT TYPE: ONE BR @ LEVELS 1-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1440 6 7 4500 A - - - + 20 1 R REC 1620 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 120 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 360 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - 1BR 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 654 3 = 1962 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4962 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 687 VA Over 120,000VA 25% = 0 VA 3686.7 VA x 100% = 3687 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 20135 VA TOTAL DEMAND ELECTRICAL LOAD: 17366 VA MINIMUM ELECTRICAL SERVICE SIZE: 83.5 AMPS 13 C 13 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: 13 C Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-311 ELECTRICAL PLAN - 1 BR - B 09/21/18 D/W SCALE: 1 ELECTRICAL PLAN - ONE BR x16 @ LEVELS 1-4 1/2"= 1'-0" SSSS SS1 S2 S1 S1 S1 S1 S1 DWDISP SC C C REF +72" MW RANGE 1 13 2 C S 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# TV TV 4 1 3 5,7 9 112 4 4 6 6 6 6 66 6 8 8 8 8 8 8 88 10 10 10 10 12 12 EF 1 12 14 UNIT TYPE: ONE BR x16 @ LEVELS 1-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1620 6 7 4500 A - - - + 20 1 R REC 1620 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 120 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 540 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - 1BR 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 613 3 = 1839 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4839 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 644 VA Over 120,000VA 25% = 0 VA 3643.65 VA x 100% = 3644 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 20012 VA TOTAL DEMAND ELECTRICAL LOAD: 17323 VA MINIMUM ELECTRICAL SERVICE SIZE: 83.3 AMPS C 13 13 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: C 13 S1 'UNIT LOAD CENTER' 6 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-312 ELECTRICAL PLAN - 1 BR - B 09/21/18 D/W SCALE: 1 ELECTRICAL PLAN - ONE BR x17 @ LEVELS 2-4 1/2"= 1'-0"SS S1 S2 S1 S1S1 S1 S1 SS SC 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# REF 1 +72" 2 MW RANGE DW 1 C SDISP 3 C C S TV TV 4 EF 1 135,7 9 11 2 4 4 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 10 10 1010 12 12 12 14 UNIT TYPE: ONE BR x17 @ LEVELS 2-4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1620 6 7 4500 A - - - + 20 1 R REC 1620 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 120 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 540 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - 1BR 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 623 3 = 1869 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4869 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 654 VA Over 120,000VA 25% = 0 VA 3654.15 VA x 100% = 3654 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 20042 VA TOTAL DEMAND ELECTRICAL LOAD: 17333 VA MINIMUM ELECTRICAL SERVICE SIZE: 83.3 AMPS C 13 13 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: C 13 S1 'UNIT LOAD CENTER' 8 Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-313 ELECTRICAL PLAN - 1 BR - S 09/21/18 D/WSCALE: 1 ELECTRICAL PLAN - ONE BR, TYPE S @ LEVEL 4 1/2"= 1'-0"SS S1 S2 S1 S1 S1 S1 S1 SS SC REF 1 +72" 2 MW RANGE DW 1 C SDISP 3 C C STV TV 4 EF 1 135,7 9 11 2 4 4 6 6 6 6 6 6 6 6 8 8 8 8 8 8 8 10 10 1010 12 12 12 14 C 13 13 C 13 'UNIT LOAD CENTER' 8 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. MOUNT RECEPTACLE WITHIN 10" OF TOP OF COUNTERTOP. 5. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES:UNIT TYPE: ONE BR, TYPE S @ LEVEL 4 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1620 6 7 4500 A - - - + 20 1 R REC 1620 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 540 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - 1BR 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 635 3 = 1905 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4905 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 667 VA Over 120,000VA 25% = 0 VA 3666.75 VA x 100% = 3667 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 20078 VA TOTAL DEMAND ELECTRICAL LOAD: 17346 VA MINIMUM ELECTRICAL SERVICE SIZE: 83.4 AMPS Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-314 ELECTRICAL PLAN - 1 BR - S 09/21/18 SCALE: 1 ELECTRICAL PLAN - NE TWO BR @LEVELS 2 & 3 1/2"= 1'-0"SSS1 S2S1 S1 S1 S1 S1 S2 S SSSC REF 1 +72" 2 RANGE MW C C S DISP 3 DISP 1 C C STV TV TV 4 EF 1 1 3 5,7 9 1142 4 6 6 6 6 6 6 6 6 8 8 8 8 1010 10 10 1212 12 12 12 14 14 1414 14 16 C 13 88 S1 SS1 S1 'UNIT LOAD CENTER'S8S10 C 13 C 13 10 12 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES: N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - 2BR 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 782 3 = 2346 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 5346 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 821 VA Over 120,000VA 25% = 0 VA 3821.1 VA x 100% = 3821 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 20519 VA TOTAL DEMAND ELECTRICAL LOAD: 17500 VA MINIMUM ELECTRICAL SERVICE SIZE: 84.1 AMPS UNIT TYPE: NE TWO BR @ LEVELS 2 & 3 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1620 6 7 4500 A - - - + 20 1 R REC 1440 8 9 864 A DISPOSAL 1 20 + 20 1 R REC 1260 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 L LIGHTING 160 12 13 540 R KITCHEN 1 20 + 20 1 R BATHROOMS 436 14 15 SPARE 1 20 + 20 1 R MEDIA CABINET 1800 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + 20 1 SPARE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-315 ELECTRICAL PLAN - 2 BR 09/21/18 SCALE: 1 ELECTRICAL PLAN - ACCESSIBLE ONE BR @ LEVEL 2 1/2"= 1'-0" S SS SSS1 S2 S1S1S1 S1 S1 DW DISP SCC C REF+72" MW RANGE 1 1 3 2 CSTV TV 4 'UNIT LOAD CENTER' EF 1 1 3 5,7 911 2 4 4 6 6 6 6 6 6 6 6 8 8 8 8 88 8 10 10 10 10 12 12 14 12 C13 13 C 13 8 1. PROVIDE 5-mA GFCI CIRCUIT BREAKER IN PANEL SERVING THIS RECEPTACLE. 2. PROVIDE 60A, 208V RECEPTACLE FOR ELECTRIC RANGE. COORDINATE EXACT POWER REQUIREMENTS WITH MANUFACTURER'S INSTALLATION INSTRUCTIONS PRIOR TO ROUGH-IN. 3. PROVIDE GFCI RECEPTACLE FOR GARBAGE DISPOSAL. 4. STRUCTURED MEDIA CABINET FOR UNIT TECHNOLOGY SYSTEMS. PROVIDE DUPLEX RECEPTACLE INSIDE MEDIA CABINET. FLAG NOTES:# 1. PROVIDE ARC-FAULT CIRCUIT-INTERRUPTER (AFCI) CIRCUIT BREAKERS FOR ALL BRANCH CIRCUITS SERVING OUTLETS OR DEVICES IN RESIDENCE, EXCEPT FOR GARAGE AND BATHROOMS, PER NEC 210.12. 2. PROVIDE TAMPER-RESISTANT TYPE RECEPTACLES IN ALL AREAS REQUIRED IN NEC 406.12. 3. VERIFY ALL EQUIPMENT AND APPLIANCE ELECTRICAL POWER CONNECTION REQUIREMENTS WITH GC PRIOR TO ROUGH-IN, FOR THE EXACT MODELS MAY HAVE CHANGED SINCE DESIGN. 4. REFER TO ARCHITECTURAL PLANS AND INTERIOR ELEVATIONS FOR RECEPTACLE AND DEVICE PLACEMENT. COORDINATE ALL RECEPTACLE MOUNTING LOCATIONS WITH FIXTURES, APPLIANCES, CABINETRY, AND OTHER EQUIPMENT. 5. COORDINATE EXACT POWER CONNECTION AND DEVICE REQUIREMENTS FOR TELECOM, AV, DATA, AND SECURITY EQUIPMENT WITH LOW VOLTAGE SYSTEMS PLANS. OR WITH ARCHITECT AND LOW VOLTAGE CONTRACTOR IF NO LOW VOLTAGE SYSTEMS PLANS ARE AVAILABLE. 6. COORDINATE 120 VOLT POWER CONNECTIONS FOR FIRE ALARM SYSTEM AND DEVICES, AND CARBON MONOXIDE DEVICES. 7. ALL EQUIPMENT, DEVICES AND CONDUCTORS SHALL BE IN NEW CONDITION AND RATED FOR THE APPLICATION. 8. COORDINATE POWER CONNECTIONS FOR MECHANICAL EQUIPMENT, OWNER PROVIDED EQUIPMENT AND APPLIANCES, AND ALL OTHER EQUIPMENT PROVIDED BY OTHER DIVISIONS WITH SUBMITTAL DATA CUT SHEETS, WIRING DIAGRAMS, MANUFACTURER'S INSTALLATION INSTRUCTIONS. FIELD COORDINATE EXACT LOCATIONS OF EQUIPMENT AND POWER CONNECTIONS WITH GC AND OTHER DIVISIONS/CONTRACTORS. 9. CONTRACTOR SHALL PROVIDE A “BOX WALK” WITH ARCHITECT AND/OR OWNER'S REPRESENTATIVE AFTER ELECTRICAL DEVICE BOXES HAVE BEEN ROUGHED-IN OR INSTALLED AND PRIOR TO WIRING AND INSTALLATION OF DEVICES. CONTRACTOR SHALL INCLUDE IN THEIR PRICE THE RELOCATION AND ADJUSTMENTS OF ELECTRICAL DEVICE BOXES TO MEET THE ARCHITECT'S/OWNER'S REQUIREMENTS. 10. ELECTRICAL CONTRACTOR IS RESPONSIBLE FOR FIELD COORDINATING THE LOCATION OF ELECTRICAL EQUIPMENT, JUNCTION BOXES, DISCONNECTS, ETC. EC SHALL BE RESPONSIBLE FOR COORDINATION AND THE ROUTING OF FEEDERS, AND BRANCH CIRCUITS. 11. THE NUMBER NEXT TO ELECTRICAL DEVICES, RECEPTACLES, AND SWITCHES INDICATES THE CIRCUIT IN THE UNIT LOAD CENTER SERVING THAT DEVICE. 12. REFER TO MECHANICAL EQUIPMENT SCHEDULE SHEET E-001 FOR SAFETY SWITCH SIZE AND CONDUCTOR SIZES COORDINATE FINAL CONNECTIONS WITH MECHANICAL CONTRACTOR AND REVIEWED SUBMITTALS. RESIDENTIAL DWELLING UNIT NOTES:UNIT TYPE: ACCESSIBLE ONE BR @ LEVEL 2 VOLTAGE: 120/208V, 1PH, 3W MOUNTING: RECESSED BUS: 100 AIC: (2) MAIN: MLO NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 1440 E REF (1) 1 20 + 20 1 A SMALL APP 1500 2 3 1580 A MW 1 20 + 20 1 A SMALL APP 1500 4 5 4500 A RANGE 2 60 + 20 1 R REC 1620 6 7 4500 A - - - + 20 1 R REC 1440 8 9 864 A DISPOSAL 1 20 + 20 1 L LIGHTING 100 10 11 1080 A DISHWASHER (1) 1 20 + 20 1 R BATHROOM 237 12 13 540 R KITCHEN 1 20 + 20 1 R MEDIA CABINET 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 20 1 SPARE 18 19 SPACE + SPACE 20 21 SPACE + SPACE 22 23 SPACE + SPACE 24 GENERAL NOTES: SPECIFIC NOTES: A. (1) PROVIDE 5-mA GFCI CIRCUIT BREAKER. B. (2) RE: 'UNIT LOAD CENTER SCHEDULE'/E-400 FOR AIC RATING. C. D.(3) E. (4) N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: BAS DATE: 7/21/2018 PROJECT NAME: Solar Vail BUILDING: UNIT #: VOLTAGE: PHASE: - 1BR 208 1 LIGHTING & GENERAL RECEPTACLES: (NEC 220.12, via NEC 220.42) AREA(S.F.): VA / S.F. LOAD 656 3 = 1968 VA SMALL APPLIANCES: (NEC 220.52(A)) 2 1500 = 3000 VA LAUNDRY CIRCUITS: (NEC 220.52(B)) 0 1500 = 0 VA 4968 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 689 VA Over 120,000VA 25% = 0 VA 3688.8 VA x 100% = 3689 VA ELECTRIC COOKING APPLIANCES: (NEC 220.55) Range 1 9000 VA = 9000 VA 9000 VA x 100% = 9000 VA APPLIANCES: (NEC 220.53) APPLIANCE # LOAD TOTAL Refrigerator 1 1440 VA = 1440 VA Dishwasher 1 1080 VA = 1080 VA Disposal 1 1656 VA = 1656 VA Microwave 1 1800 VA = 1800 VA 5976 VA x 75% = 4482 VA MECHANICAL EQUIPMENT: EF-1 1 17 VA = 17 VA 0 0 VA = 0 VA 17 X 100% = 17 VA MISCELLANEOUS EQUIPMENT: IT 1 180 VA = 180 VA 180 X 100% = 180 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 20141 VA TOTAL DEMAND ELECTRICAL LOAD: 17368 VA MINIMUM ELECTRICAL SERVICE SIZE: 83.5 AMPS Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-316 ELECTRICAL PLAN - 2 BR 09/21/18 SPACE200A/3PSWB 2000A 208Y/120V, 3ø, 4W 2000/3MCCB M 'M1' 150A/3P'P1' PARKING LEVEL LEVEL 1 600A/2PUNIT LOAD CENTER TYPICAL OF 14 LEVEL 2 UNIT LOAD CENTER TYPICAL OF 17 600A/3PLEVEL 3 'DP3' UNIT LOAD CENTER TYPICAL OF 17 250A/3P'P3' LEVEL 4 UNIT LOAD CENTER TYPICAL OF 17 #3/0 GROUNDING ELECTRODE CONDUCTORS SIZED PER SERVICE WIRING SCHEDULE. BLDG. STEEL I.A.W. N.E.C. 250-52(A)(2) WATER SERVICE I.A.W. N.E.C. 250-52(A)(1) 20 L.F. OF #4CU ENCASED IN MIN. 2" OF CONCRETE. I.A.W. N.E.C. 250-52(A)(3) N G 70A/3P'L1' N L E N L 110A/3P110A/3P 70A/3P 15HP ELEV-1 E 106kVA NATURAL GAS GENERATOR.T SCALE: 1 ELECTRICAL ONE-LINE DIAGRAM NOT TO SCALE SERVICE WIRING SCHEDULE AMPS ALUMINUM (4W) GROUNDING ELECTRODE CONDUCTOR 3Ø, 4 WIRE W.P. M.F. C.E.C. G.RING G. ROD 2000 7[(4-500 KCMIL) 3 1/2"C] #3/0 CU #3/0 CU #3/0 CU #3/0 CU #6 CU CONDUIT SIZES ARE BASED ON NEC TABLE 4 (RNC) AND TABLE 5 (THHN INSULATION). ABBREVIATIONS: W.P. - WATER PIPE; M.F. - METAL FRAME OR STRUCTURE; C.E.C. - CONCRETE ENCASED ELECTRODE; G.RING. - GROUND RING; G.ROD - GROUND ROD, PIPE OR PLATE ELECTRODE WIRING SCHEDULE - ALUMINUM AMPS (2WG) (3WG) (4WG) 1Ø, 2 WIRE, GROUND 1Ø, 3 WIRE, GROUND OR 3Ø, 3 WIRE, GROUND 3Ø, 4 WIRE, GROUND 125 (2#2/0 & 1#4 G) 1 1/2"C (3#2/0 & 1#4 G) 2"C (4#2/0 & 1#4 G) 2"C 150 (2#3/0 & 1#4 G) 1 1/2"C (3#3/0 & 1#4 G) 2"C (4#3/0 & 1#4 G) 2 1/2"C 200 (2-250 KCMIL & 1#4 G) 2"C (3-250 KCMIL & 1#4 G) 2 1/2"C (4-250 KCMIL & 1#4 G) 3"C 250 (2-350 KCMIL & 1#2 G) 2 1/2"C (3-350 KCMIL & 1#2 G) 3"C (4-350 KCMIL & 1#2 G) 3"C 600 2[(2-500 KCMIL & 1#2/0 G) 2 1/2"C] 2[(3-500 KCMIL & 1#2/0 G) 3"C] 2[(4-500 KCMIL & 1#2/0 G) 3 1/2"C] CONDUCTOR SIZES ARE BASED ON 75° TERMINATIONS. CONDUIT SIZES ARE BASED ON NEC TABLE 4 (RNC) AND TABLE 5 (THHN INSULATION). WIRING SCHEDULE - COPPER AMPS (2WG) (3WG) (4WG) 1Ø, 2 WIRE, GROUND 1Ø, 3 WIRE, GROUND OR 3Ø, 3 WIRE, GROUND 3Ø, 4 WIRE, GROUND 20 (2#12 & 1#12 G) 3/4"C (3#12 & 1#12 G) 3/4"C (4#12 & 1#12 G) 3/4"C 30 (2#10 & 1#10 G) 3/4"C (3#10 & 1#10 G) 3/4"C (4#10 & 1#10 G) 3/4"C 40 (2#8 & 1#10 G) 3/4"C (3#8 & 1#10 G) 3/4"C (4#8 & 1#10 G) 1"C 50 (2#6 & 1#10 G) 3/4"C (3#6 & 1#10 G) 1"C (4#6 & 1#10 G) 1"C 60 (2#4 & 1#10 G) 1"C (3#4 & 1#10 G) 1"C (4#4 & 1#10 G) 1 1/4"C 70 (2#4 & 1#8 G) 1"C (3#4 & 1#8 G) 1 1/4"C (4#4 & 1#8 G) 1 1/4"C 80 (2#2 & 1#8 G) 1"C (3#2 & 1#8 G) 1 1/4"C (4#2 & 1#8 G) 1 1/2"C 90 (2#2 & 1#8 G) 1"C (3#2 & 1#8 G) 1 1/4"C (4#2 & 1#8 G) 1 1/2"C 100 (2#1 & 1#8 G) 1 1/4"C (3#1 & 1#8 G) 1 1/2"C (4#1 & 1#8 G) 1 1/2"C 110 (2#1 & 1#6 G) 1 1/4"C (3#1 & 1#6 G) 1 1/2"C (4#1 & 1#6 G) 1 1/2"C CONDUCTOR SIZES ARE BASED ON 60° TERMINATIONS LESS THAN 100A AND 75° TERMINATIONS GREATER THAN 100A CONDUIT SIZES ARE BASED ON NEC TABLE 4 (RNC) AND TABLE 5 (THHN INSULATION).150A(4WG)AL150A(4WG)AL600A(4WG)AL250A(4WG)AL70A(4WG)CU110A(4WG)CU110A(4WG)CU2000A(4W)ALUTILITY TRANSFORMER ATS-E. 125A, 4-POLE AUTOMATIC TRANSFER SWITCH ATS-S. 70A, 4-POLE AUTOMATIC TRANSFER SWITCH 110A/3PSEPARATELY ENCLOSED CIRCUIT BREAKER WITH SHUNT TRIP. HD ST 1. HEAT DETECTOR ACTIVATION IN ELEVATOR SHAFT OR AT ELEVATOR CONTROLLER LOCATION SHALL ACTIVATE SHUNT TRIP TO SHUT DOWN ELEVATOR POWER. 2. PUSH BUTTON TO ACTIVATE SHUNT TRIP CIRCUIT BREAKER LOCATED ON EXTERIOR OF BUILDING. REFER TO SHEET E-201 FOR LOCATION. 3. REFER TO 'UNIT LOAD CENTER SCHEDULE' ON THIS SHEET FOR FEEDER SIZE. 4. REFER TO 'UNIT LOAD CENTER SCHEDULE' ON THIS SHEET FOR SHORT-CIRCUIT RATING OF LOAD CENTER. 5. FEEDER UPSIZED FOR VOLTAGE DROP. FLAG NOTES:# 1 ST 2 70A(4WG)CU 3 3 UNIT LOAD CENTER SCHEDULE UNIT FEEDER SIZE AIC RATING OF LOAD CENTER 101 125A(3WG)AL 10,000 102 125A(3WG)AL 10,000 103 125A(3WG)AL 10,000 104 125A(3WG)AL 10,000 105 125A(3WG)AL 10,000 106 125A(3WG)AL 10,000 107 125A(3WG)AL 10,000 108 125A(3WG)AL 22,000 109 125A(3WG)AL 22,000 110 125A(3WG)AL 10,000 111 125A(3WG)AL 10,000 112 125A(3WG)AL 10,000 113 125A(3WG)AL 10,000 114 125A(3WG)AL 10,000 201 125A(3WG)AL 10,000 202 200A(3WG)AL 10,000 203 125A(3WG)AL 10,000 204 125A(3WG)AL 10,000 205 125A(3WG)AL 10,000 206 125A(3WG)AL 10,000 207 125A(3WG)AL 10,000 208 125A(3WG)AL 10,000 209 125A(3WG)AL 10,000 210 125A(3WG)AL 22,000 211 125A(3WG)AL 22,000 212 125A(3WG)AL 10,000 213 125A(3WG)AL 10,000 214 125A(3WG)AL 10,000 215 125A(3WG)AL 10,000 216 125A(3WG)AL 10,000 217 125A(3WG)AL 10,000 301 125A(3WG)AL 22,000 302 125A(3WG)AL 10,000 303 125A(3WG)AL 10,000 304 125A(3WG)AL 10,000 305 125A(3WG)AL 10,000 306 125A(3WG)AL 22,000 307 125A(3WG)AL 22,000 308 125A(3WG)AL 22,000 309 125A(3WG)AL 22,000 310 125A(3WG)AL 10,000 311 125A(3WG)AL 22,000 312 200A(3WG)AL 22,000 313 125A(3WG)AL 10,000 314 200A(3WG)AL 10,000 315 125A(3WG)AL 10,000 316 200A(3WG)AL 10,000 317 200A(3WG)AL 22,000 401 125A(3WG)AL 22,000 402 125A(3WG)AL 10,000 403 125A(3WG)AL 10,000 404 200A(3WG)AL 22,000 405 125A(3WG)AL 10,000 406 125A(3WG)AL 22,000 407 125A(3WG)AL 22,000 408 125A(3WG)AL 22,000 409 125A(3WG)AL 22,000 410 125A(3WG)AL 10,000 411 125A(3WG)AL 10,000 412 200A(3WG)AL 10,000 413 200A(3WG)AL 10,000 414 200A(3WG)AL 10,000 415 200A(3WG)AL 10,000 416 225A(3WG)AL 10,000 417 225A(3WG)AL 10,000 SHORT CIRCUIT / VOLTAGE DROP CALCULATION SUMMARY POINTTAG VOLTAGE / PHASE LENGTH (FT) COPPER / ALUMINUM CONDUIT WIRE SIZE # OF SETS FEEDER VOLTAGE DROP (%) TOTAL VOLTAGE DROP (%) Isc AVAILABLE UPSTREAM Isc (FAULT) F1 SWB 208V, 3Ø 120 A N 500 7 0.8% 0.8% 99,500 59,794 F2 M1 208V, 3Ø 20 A S 3X 1 0.1% 1.0% 59,794 28,095 F3 P1 208V, 3Ø 20 A S 3X 1 0.2% 1.0% 59,794 28,095 F4 ATS-S 208V, 3Ø 20 C S 4 1 0.1% 0.9% 59,794 16,534 F5 L1 208V, 3Ø 30 C S 4 1 0.1% 1.0% 16,534 7,929 F6 ATS-E 208V, 3Ø 20 C S 1 1 0.1% 0.9% 59,794 25,276 F7 ELEV-1 208V, 3Ø 100 C S 1 1 0.6% 1.6% 25,276 6,504 F8 DP1 208V, 3Ø 20 A S 500 2 0.2% 1.0% 59,794 47,250 F9 UNIT 101 LC 208V, 1Ø 100 A S 2X 1 1.1% 2.1% 47,250 6,453 F10 UNIT 102 LC 208V, 1Ø 130 A S 2X 1 1.5% 2.5% 47,250 5,125 F11 UNIT 103 LC 208V, 1Ø 120 A S 2X 1 1.4% 2.3% 47,250 5,503 F12 UNIT 104 LC 208V, 1Ø 120 A S 2X 1 1.4% 2.3% 47,250 5,503 F13 UNIT 105 LC 208V, 1Ø 100 A S 2X 1 1.1% 2.1% 47,250 6,453 F14 UNIT 106 LC 208V, 1Ø 85 A S 2X 1 1.0% 2.0% 47,250 7,413 F15 UNIT 107 LC 208V, 1Ø 95 A S 2X 1 1.1% 2.1% 47,250 6,744 F16 UNIT 108 LC 208V, 1Ø 60 A S 2X 1 0.7% 1.7% 47,250 9,857 F17 UNIT 109 LC 208V, 1Ø 40 A S 2X 1 0.5% 1.5% 47,250 13,389 F18 UNIT 110 LC 208V, 1Ø 70 A S 2X 1 0.8% 1.8% 47,250 8,709 F19 UNIT 111 LC 208V, 1Ø 70 A S 2X 1 0.8% 1.8% 47,250 8,709 F20 UNIT 112 LC 208V, 1Ø 90 A S 2X 1 1.0% 2.0% 47,250 7,063 F21 UNIT 113 LC 208V, 1Ø 80 A S 2X 1 0.9% 1.9% 47,250 7,800 F22 UNIT 114 LC 208V, 1Ø 100 A S 2X 1 1.1% 2.1% 47,250 6,453 F23 UNIT 201 LC 208V, 1Ø 120 A S 2X 1 1.4% 2.3% 47,250 5,503 F24 UNIT 202 LC 208V, 1Ø 150 A S 250 1 0.9% 1.9% 47,250 7,135 F25 UNIT 203 LC 208V, 1Ø 120 A S 2X 1 1.4% 2.3% 47,250 5,503 F26 UNIT 204 LC 208V, 1Ø 130 A S 2X 1 1.5% 2.5% 47,250 5,125 F27 UNIT 205 LC 208V, 1Ø 110 A S 2X 1 1.2% 2.2% 47,250 5,940 F28 UNIT 206 LC 208V, 1Ø 90 A S 2X 1 1.0% 2.0% 47,250 7,063 F29 UNIT 207 LC 208V, 1Ø 100 A S 2X 1 1.1% 2.1% 47,250 6,453 F30 UNIT 208 LC 208V, 1Ø 75 A S 2X 1 0.8% 1.8% 47,250 8,229 F31 UNIT 209 LC 208V, 1Ø 80 A S 2X 1 0.9% 1.9% 47,250 7,800 F32 UNIT 210 LC 208V, 1Ø 60 A S 2X 1 0.7% 1.7% 47,250 9,857 F33 UNIT 211 LC 208V, 1Ø 55 A S 2X 1 0.6% 1.6% 47,250 10,553 F34 UNIT 212 LC 208V, 1Ø 80 A S 2X 1 0.9% 1.9% 47,250 7,800 F35 UNIT 213 LC 208V, 1Ø 75 A S 2X 1 0.8% 1.8% 47,250 8,229 F36 UNIT 214 LC 208V, 1Ø 95 A S 2X 1 1.1% 2.1% 47,250 6,744 F37 UNIT 215 LC 208V, 1Ø 90 A S 2X 1 1.0% 2.0% 47,250 7,063 F38 UNIT 216 LC 208V, 1Ø 110 A S 2X 1 1.2% 2.2% 47,250 5,940 F39 UNIT 217 LC 208V, 3Ø 110 A S 2X 1 1.2% 2.2% 47,250 6,728 F40 P3 208V, 3Ø 80 A S 350 1 0.3% 1.1% 59,794 16,737 F41 DP3 208V, 3Ø 80 A S 500 2 0.8% 1.6% 59,794 28,999 F42 UNIT 301 LC 208V, 1Ø 40 A S 2X 1 0.5% 2.0% 28,999 11,363 F43 UNIT 302 LC 208V, 1Ø 75 A S 2X 1 0.9% 2.4% 28,999 7,416 F44 UNIT 303 LC 208V, 1Ø 65 A S 2X 1 0.7% 2.3% 28,999 8,233 F45 UNIT 304 LC 208V, 1Ø 80 A S 2X 1 0.9% 2.5% 28,999 7,066 F46 UNIT 305 LC 208V, 1Ø 60 A S 2X 1 0.7% 2.2% 28,999 8,713 F47 UNIT 306 LC 208V, 1Ø 40 A S 2X 1 0.5% 2.0% 28,999 11,363 F48 UNIT 307 LC 208V, 1Ø 30 A S 2X 1 0.3% 1.9% 28,999 13,400 F49 UNIT 308 LC 208V, 1Ø 40 A S 2X 1 0.5% 2.0% 28,999 11,363 F50 UNIT 309 LC 208V, 1Ø 20 A S 2X 1 0.2% 1.8% 28,999 16,328 F51 UNIT 310 LC 208V, 1Ø 70 A S 2X 1 0.8% 2.4% 28,999 7,803 F52 UNIT 311 LC 208V, 1Ø 40 A S 2X 1 0.5% 2.0% 28,999 11,363 F53 UNIT 312 LC 208V, 1Ø 90 A S 250 1 0.6% 2.1% 28,999 9,445 F54 UNIT 313 LC 208V, 1Ø 60 A S 2X 1 0.7% 2.2% 28,999 8,713 F55 UNIT 314 LC 208V, 1Ø 105 A S 250 1 0.6% 2.2% 28,999 8,491 F56 UNIT 315 LC 208V, 1Ø 75 A S 2X 1 0.9% 2.4% 28,999 7,416 F57 UNIT 316 LC 208V, 1Ø 125 A S 250 1 0.8% 2.3% 28,999 7,483 F58 UNIT 317 LC 208V, 1Ø 95 A S 250 1 0.6% 2.1% 28,999 9,104 F59 UNIT 401 LC 208V, 1Ø 55 A S 2X 1 0.6% 2.2% 28,999 9,253 F60 UNIT 402 LC 208V, 1Ø 85 A S 2X 1 1.0% 2.5% 28,999 6,747 F61 UNIT 403 LC 208V, 1Ø 70 A S 2X 1 0.8% 2.4% 28,999 7,803 F62 UNIT 404 LC 208V, 1Ø 90 A S 250 1 0.6% 2.1% 28,999 9,445 F63 UNIT 405 LC 208V, 1Ø 70 A S 2X 1 0.8% 2.4% 28,999 7,803 F64 UNIT 406 LC 208V, 1Ø 50 A S 2X 1 0.6% 2.1% 28,999 9,863 F65 UNIT 407 LC 208V, 1Ø 40 A S 2X 1 0.5% 2.0% 28,999 11,363 F66 UNIT 408 LC 208V, 1Ø 50 A S 2X 1 0.6% 2.1% 28,999 9,863 F67 UNIT 409 LC 208V, 1Ø 30 A S 2X 1 0.3% 1.9% 28,999 13,400 F68 UNIT 410 LC 208V, 1Ø 80 A S 2X 1 0.9% 2.5% 28,999 7,066 F69 UNIT 411 LC 208V, 1Ø 70 A S 2X 1 0.8% 2.4% 28,999 7,803 F70 UNIT 412 LC 208V, 1Ø 100 A S 250 1 0.6% 2.2% 28,999 8,787 F71 UNIT 413 LC 208V, 1Ø 100 A S 250 1 0.6% 2.2% 28,999 8,787 F72 UNIT 414 LC 208V, 1Ø 115 A S 250 1 0.7% 2.3% 28,999 7,955 F73 UNIT 415 LC 208V, 1Ø 120 A S 250 1 0.7% 2.3% 28,999 7,712 F74 UNIT 416 LC 208V, 1Ø 135 A S 250 1 0.8% 2.4% 28,999 7,064 F75 UNIT 417 LC 208V, 1Ø 140 A S 250 1 0.9% 2.4% 28,999 6,871 ** FOR DESIGN PURPOSES, A 500KVA UTILITY TRANSFORMER WITH A MAXIMUM AVAILABLE (SYMMETRICAL) FALUT AT THE SECONDARY OF 99,500 AMPS HAS BEEN ASSUMED. ACTUAL TRANSFORMER AND FAULT CURRENT INFORMATION SHALL BE PROVIDED TO THE ELECTRICAL ENGINEER, PRIOR TO PURCHASING ANY ELECTRICAL EQUIPMENT, TO ALLOW VERIFICATION OF THESE CALCULATIONS. SHORT CIRCUIT CALCULATIONS ARE FURNISHED FOR ALL FAULT LEVELS ABOVE 10,000 AMPS @ 208 VOLT. ANY FAULT CURRENT BELOW THIS LEVEL IS CONSIDERED SAFE FOR THE ELECTRICAL SYSTEM TO CLEAR OR EQUIPMENT IS BUILT TO WITHSTAND THIS LEVEL OF FAULT SAFELY. F1 F2 F3 F37 F36 F5 F4 F6 F7 4 4 4 4 4 'DP1' 600A(4WG)ALF8 70A(4WG)CU #1/0 CU GROUNDING ELECTRODE CONDUCTORS. BLDG. STEEL I.A.W. N.E.C. 250-52(A)(2) WATER SERVICE I.A.W. N.E.C. 250-52(A)(1) 20 L.F. OF #4CU ENCASED IN MIN. 2" OF CONCRETE. I.A.W. N.E.C. 250-52(A)(3) N G Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-400 ELECTRICAL DIAGRAMS 09/21/18 GUTTERMELT CONTROL DIAGRAM NO SCALE 120 VOLT N H PANEL ICESTOP CABLE ICESTOP CABLE ICESTOP CABLE CONTACTOR 30-mA GFCI CIRCUIT BREAKERS. GUTTERMELT TEMPERATURE SENSOR TO LOCK-OUT GUTTERMELT ABOVE 40°F (ADJ.) OR (MOISTURE/TEMPERATURE SENSOR). EXTERIOR LIGHTING CONTROL DIAGRAM NO SCALE 120V TC TO EXTERIOR LIGHTS PC PHOTOCELL (WPS-5527K) MOUNTED ON ROOF FACING NORTH. DOUGLAS LIGHTING CONTROL PANEL #WPAK-33518-S TYPICAL SYSTEM CLOCK NO SCALE TYPICAL DEVICE ALIGNMENT EQ EQ 6"MIN. ℄ ℄ ℄ DOOR WINDOW EQ EQ ℄LIGHTING CONTROL ℄ ℄ OFFSET COMMUNICATIONS DEVICES FROM POWER DEVICES TO EITHER OPPOSITE SIDE OF STUD BAY, OR ADJACENT STUD BAY. NOTES: 1. IF ALIGNMENT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. EQ BACKSPLASH ABOVE COUNTER DEVICE RECEPTACLE COUNTERTOP EQ FINISHED FLOOR FINISHED CEILING 6" MIN. 20" MAX. ALIGN DEVICES (OUTLETS, CONTROLS, ETC.) VERTICALLY. DO NOT VERTICALLY ALIGN POWER AND COMMUNICATIONS DEVICES SIMULTANEOUSLY. 18" 48"64" 78" 90" 78" 64" 90" 6"MIN FIRE ALARM DEVICES 48" ELECTRICAL DEVICES 96" NOTES: 1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. WALL-MOUNT NO SCALE TYPICAL DEVICE MOUNTING HEIGHTS OC DLV S CBC TS TC ANN FACP SH SH F 120" MAX. 80" MIN. 96" MAX. TOP OF DEVICE 9'-0"+ CEILING 8'-0" CEILING TOP OF CABINET TOP OF CABINET TOP OF DEVICE CL OF DEVICE TOP OF DEVICE TOP OF CABINET TOP OF CABINET BOTTOM OF DEVICE MINIMUM, TOP OF DEVICE FINISHED FLOOR FINISHED CEILING 18" TOP OF DEVICE 48" MINIMUM, TOP OF DEVICE BOTTOM OF DEVICE TOP OF CABINET TOP OF CABINET 90" 6"MIN. 96" NOTES: 1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. TYPICAL DEVICE MOUNTING HEIGHTS I I CR FINISHED FLOOR 48" 84" FINISHED CEILING 90" 78" 64" 24" NO SCALE I WALL-MTDCABINET CPUAPS ACP K C VCT CK MAV TV S ANN FACP SH SH F 80" MIN. 96" MAX. 120" MAX. CL OF DEVICE CL OF DEVICE TOP OF DEVICE TOP OF CABINET 8'-0" CEILING 9'-0"+ CEILING CL OF DEVICE LOW VOLTAGE DEVICES FIRE ALARM DEVICES A B ICESTOP CABLE Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-401 ELECTRICAL DIAGRAMS 09/21/18 1. 3/4" PLYWOOD - 'AC' GRADE. COAT WITH FIRE RETARDANT PAINT. 'A' SIDE SHALL FACE INTERIOR OF ROOM. 2. LADDER-STYLE CABLE RUNWAY - 12" WIDE. PROVIDE CHATSWORTH PRODUCTS OR EQUAL. 3. PRIMARY BONDING BUSBAR (PBB). PROVIDE 12"X4" BUSBAR BY HARGER, CHATSWORTH, OR EQUAL. 4. (3) 4" C. FROM SERVICE PROVIDER PEDESTAL, ROUTED THROUGH THE GARAGE. RE: ELECTRICAL SITE PLAN/E-100. EXTEND CONDUIT 3" INTO ER/MDF. PROVIDE FIRESTOPPING AS REQUIRED. 5. CATV AND VOICE/DATA DEMARC POINT. 6. 45U 4-POST EQUIPMENT RACK FRAME - FLOOR MOUNT. PROVIDE CHATSWORTH OR EQUAL. 7. (3) 4" C. SLEEVES TO ABOVE ACCESSIBLE CEILING. EXTEND SLEEVES 3" ON EITHER SIDE OF WALL ASSEMBLY. PROVIDE FIRESTOPPING AS REQUIRED. 8. VERTICAL CABLE MANAGEMENT - 6" WIDE, DOUBLE-SIDED. PROVIDE CHATSWORTH "VELOCITY" OR EQUAL. 9. WALL MOUNT EQUIPMENT CABINET. PROVIDE CHATSWORTH OR EQUAL. 10. 66-BLOCK PUNCH DOWN FOR PHONE SYSTEM. FLAG NOTES:# 1. PROVIDE CONDUIT SLEEVES THROUGH WALLS TO STRUCTURE TO FACILITATE CABLING. PROVIDE FIRE-RATED PATHWAYS WHERE REQUIRED. 2. ALL LOW VOLTAGE CONDUIT STUBBED OUT ABOVE FINISHED CEILINGS SHALL HAVE LONG RADIUS SWEEPS. 3. CABLE TIES SHALL BE RELEASABLE AND COMPOSED OF HOOK AND LOOP, RUBBER OR SOFT POLYMER. ZIP-TIES OR EQUAL SHALL NOT BE USED. 4. ROUTE ALL CABLING NOT IN CONDUIT VIA J-HOOKS, ARLINGTON LOOPS OR SLINGS SUSPENDED FROM STRUCTURE. CABLING SHALL NOT RUN UNSUPPORTED FOR LENGTHS GREATER THAN 5'-0". 5. ALL VOICE/DATA CABLING SHALL BE TERMINATED ON RACK MOUNTED PATCH PANELS. 6. ALL INFRASTRUCTURE SUPPORTING VOICE/DATA STRUCTURED CABLING SYSTEMS (RACKING, GROUNDING, PATHWAYS, ETC.) SHALL MEET BICSI STANDARDS. 7. ALL TELECOMMUNICATIONS CABLING SHALL BE HOMERUN TO THE NEAREST SERVING TR/IDF. NOTES: 6 3 4 1 2 7 SCALE:1 MDF ENLARGED PLAN 1/2" = 1'-0" CABLE RUNWAY, BOTTOM AT +90"AFF. SCALE:2 MDF -RACK ELEVATIONS 1/2" = 1'-0" 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 VERTICAL CABLE MGMTFOUR-POST DIST RACK 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 VERTICAL CABLE MGMTFOUR-POST DIST RACKRESERVED FOR OWNER EQUIPMENT.VERTICAL CABLE MANAGER. CHATSWORTH VELOCITY 6" WIDE DOUBLE-SIDED, TYPICAL. HORIZONTAL CABLE MGMT 8 , TYP. 2U HORIZONTAL CABLE MANAGEMENT. PROVIDE CHATSWORTH OR EQUAL. TYPICAL. 5 48 PORT POE LAN SWITCH 10 2 E-402 48 PORT PATCH PANEL 48 PORT POE LAN SWITCH 48 PORT PATCH PANEL HORIZONTAL CABLE MGMT 48 PORT POE LAN SWITCH 48 PORT PATCH PANEL 48 PORT POE LAN SWITCH 48 PORT PATCH PANEL HORIZONTAL CABLE MGMT DATA PATCHPANEL. PROVIDE BLUE CONNECTORS, TYPICAL. CCTV CONNECTORS SHALL BE GREEN. UPS PROVIDED BY OTHERS. Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-402 TECHNOLOGY ENLARGED PLANS 09/21/18 LEVEL 4 LEVEL 3 LEVEL 2 LEVEL 1 PARKING LEVEL ER/MDF 2"C. ROOF SCALE:1 PATHWAYS & SPACES RISER DIAGRAM NOT TO SCALE WEATHERHEAD TERMINATION (FUTURE USE) 1. CABLING MAY BE ROUTED VIA CABLE TRAY, J-HOOKS, ARLINGTON LOOPS OR EQUAL ABOVE ACCESSIBLE CEILING. 2. PROVIDE LONG RADIUS SWEEPS (4X) ON ALL COMMUNICATIONS CONDUIT PATHWAYS. 3. CABLING WITHIN RESIDENTIAL UNITS MAY BE RUN "WILD" FROM STRUCTURED MEDIA CABINET TO COMMUNICATIONS OUTLET BOX. NOTES: RESIDENTIAL UNIT TYPICAL STRUCTURED MEDIA CABINET. RESIDENTIAL UNIT RESIDENTIAL UNIT RESIDENTIAL UNIT 4" CONDUIT SLEEVES, QTY. AS REQUIRED, TYPICAL. PROVIDE FIRESTOPPING AS REQUIRED FOR FIRE RATED PARTITIONS. TYPICAL. LEVEL 2 LEVEL 1 PARKING LEVEL ER/MDF SCALE: 2 COMMUNICATIONS BONDING DIAGRAM NOT TO SCALE ACCESSIBLE CEILING ACCESSIBLE CEILING ACCESSIBLE CEILING ACCESSIBLE CEILING PBB G BOND TO BUILDING STEEL, TYPICAL. TELECOMMUNICATIONS BONDING CONDUCTOR (TBC). #2/0 AWG INSULATED COPPER. BOND TO GROUNDING BUS IN ELECTRICAL PANEL. FIELD COORDINATE WORK WITH ELECTRICAL CONTRACTOR. DATA PHONE CATV CABLETRAY, TYPICAL. NETWORK RACK, TYPICAL. BONDING NOTES: 1. ALL BONDING CONNECTIONS SHALL BE MADE WITH HEAVY DUTY 2-HOLE COMPRESSION LUGS WITH STAINLESS STEEL SCREWS AND LOCKING NUTS, TWO SCREWS & NUTS PER LUG. 2. PROVIDE BONDING BUSBARS IN ALL COMMUNICATION CLOSETS. BOND PRIMARY BUSBAR (PBB) TO BUILDING MAIN ELECTRICAL SERVICE GROUND WITH #2/0 AWG INSULATED STRANDED COPPER CONDUCTOR AND #2/0 BETWEEN BUSBARS. BONDING TO BUILDING STRUCTURE, CONDUITS, UTILITY PIPING, OR ELECTRICAL SUB-PANELS IN LIEU OF BONDING TO BUILDING MAIN ELECTRICAL SERVICE GROUND IS NOT ACCEPTABLE. 3. BONDING CONDUCTOR BETWEEN PBB AND END BUSBAR SHALL BE CONTINUOUS. PROVIDE C-TYPE COMPRESSION TAPS TO FEED INTERMEDIATE BUSBARS. 4. BOND EACH CONDUIT IN ALL COMMUNICATIONS ROOMS WITH #6 AWG INSULATED STRANDED COPPER BONDING CONDUCTOR TO BONDING BUSBAR. ROUTE CONDUCTOR IN CABLE RUNWAY TO BONDING BUSBAR. 5. BOND CABLE TRAY AND RUNWAY WITH #6 AWG INSULATED STRANDED COPPER BONDING CONDUCTOR TO BONDING BUSBAR. TWO-HOLE COMPRESSION LUGS, TYPICAL.FRONT ELEVATION #6 AWG INSULATED BONDING COND. TO COMM. EQUIP. MOUNTING BRACKET, TYPICAL. BONDING BUSBAR, TYPICAL. INSULATOR, TYPICAL. #2/0 AWG INSULATED BONDING COND. FROM TBB. PLAN SYMBOL: CONNECT TO: · CABLE RUNWAY AND CABLE TRAY · BUILDING STEEL OR CONDUIT RISER · EACH DATA RACK #6 AWG, TYPICAL. TO TELECOMMUNICATIONS BONDING BACKBONE (TBB). TO TELECOMMUNICATIONS BONDING CONDUCTOR (TBC).4"VARIES: 12" - 20" CONNECT TO: · CABLE RUNWAY AND CABLE TRAY · BUILDING STEEL OR CONDUIT RISER · EACH DATA RACK · PARALLEL END-OF-LINE SBB (BACKBONE BONDING CONDUCTOR) #6 AWG, TYPICAL. TO TELECOMMUNICATIONS BONDING BACKBONE (TBB). 2"12" #2/0 #2/0 #2/0 TYPICAL SBB TYPICAL PBB SCALE: 3 COMMUNICATIONS BONDING BUSBAR DIAGRAM NOT TO SCALE TO COMM. SERVICE PROVIDER PEDESTALS. TO CATV SERVICE PROVIDER PEDESTAL. (2) 4"C. (1) 4"C. 1"C., TYPICAL. Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-500 TECHNOLOGY RISER DIAGRAMS 09/21/18 SCALE: 1 COMMUNICATIONS RISER DIAGRAM NOT TO SCALE PHONE DATA MCC NETWORKING EQUIPMENT BY OWNER (TYPICAL). TO SERVICE PROVIDER PEDESTAL. ER/MDF SERVICE PROVIDER DEMARCATION POINT. RACK MOUNT 48-PORT RJ45 PATCH PANEL, TYPICAL. TERMINATE 568B. TERMINATE HORIZONTAL CABLING ON APPROPRIATE PATCH PANEL. 25PR CAT5E UTP BY CONTRACTOR. 12STR SMOF BY CONTRACTOR. CAT6 CAT6 TYPICAL VOICE/DATA OUTLETS. 1. ALL ANALOG VOICE OUTLETS SHALL BE SERVED FROM THE ER/MDF. NOTES: SCALE: 2 CATV RISER DIAGRAM NOT TO SCALE TO SERVICE PROVIDER PEDESTAL. ER/MDF SERVICE PROVIDER DEMARCATION POINT. CATV TYPICAL RESIDENTIAL UNIT CAT6 TYPICAL UNIT DATA OUTLETS.4PR CAT6 4PR CAT6 TYPICAL RESIDENTIAL UNIT TYPICAL UNIT TV OUTLETS. TV TV RG6/U RG6/U RG6/U PROVIDE 75 OHM TERMINATION FOR UNUSED PORTS. Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title E-501 TECHNOLOGY RISER DIAGRAMS 09/21/18 COMMUNICATIONS OUTLET BOX DIAGRAM THREADED NIPPLE WITH PROTECTIVE BUSHING. COMMUNICATIONS CABLING. CONDUIT PATHWAY, UP OR DOWN FROM OUTLET BOX. SINGLE DEVICE MUD-RING. LARGE CAPACITY OUTLET BOX; HUBBELL HBL260 OR EQUAL. 4-11/16" x 4-11/16" x 3-1/4", TYPICAL UNO. NO SCALE DOUBLE DATA OUTLET DIAGRAM COR MODULAR CAT6 CONNECTOR (BLUE). TERMINATE T568B. BLANK MODULAR INSERT, MATCH FACEPLATE COLOR. 3-PORT MODULAR COMMUNICATIONS FACEPLATE, COLOR TO MATCH RECEPTACLES. (2) 4PRCAT6 UTP CABLE(BLUE JACKET). PLAN SYMBOL:NO SCALE OUTLET LABEL OUTLET LABEL NOTES: 1. PROVIDE LEVEL 1 ADMINISTRATION PER ANSI/TIA/EIA-606. 2. PROVIDE LABEL ON FRONT OF FACEPLATE. 1" C. WALL PHONE OUTLET DIAGRAM NOTES: 1. PROVIDE LEVEL 1 ADMINISTRATION PER ANSI/TIA/EIA-606. 2. PROVIDE LABEL ON FRONT OF FACEPLATE. W CAT3 CONNECTOR (BLUE). TERMINATE T568B. STAINLESS STEEL WALL PHONE MOUNT PLATE, WITH RECESSED JACK PORT. PLAN SYMBOL:NO SCALE 4PR CAT3 UTP CABLE (BLUE JACKET). 1" C. WIRELESS ACCESS POINT OUTLET DIAGRAM PLAN SYMBOL:NO SCALE SURFACE MOUNT "BISCUIT" JACK W/ (1) CAT6 JACK.4PR CAT6A UTP CABLING (BLUE ). ROUTE TO SERVING IDF. STRUCTURE. WAP #1 J-HOOK OR EQUAL. PROVIDE 15'-0" CABLE COILED FOR FIELD-ADJUSTMENT OF OUTLET LOCATION. ACCESS POINTS AND PATCH CABLES OWNER PROVIDED. ACCESSIBLE CEILING.12"T568B STANDARD 8-POSITION / 8-CONDUCTOR DEVICE WIRING DIAGRAM 1 1 PAIR 2 PAIR 2 4 5 1 2 PIN MODULAR CONNECTOR PINOUTS 87 6 4 5 3 2 7 2 3 5 4 6 PAIR 1 PAIR 3 PAIR 3 PAIR 1 8 PAIR 4 PAIR 4 2 3 4 1 PAIR COLOR CODE 2 3 4 1 3 6 7 8 BLUE WHITE/BLUE WHITE/ORANGE ORANGE WHITE/GREEN GREEN WHITE/BROWN BROWN NO SCALE 1 002 1 003 1 001 1 001 SEQUENTIALLY NUMBERED PORT IDENTIFIER TYPICAL OUTLET & CABLING LABELING CONVENTION NO SCALE JACK 'A' PORT # JACK 'C' PORT # JACK 'B' PORT # NOTES: 1. ALL LABELS SHALL BE MACHINE PRINTED. 2. LABELING CONVENTION APPLIES TO BOTH FACEPLATE AND CABLING. 3. PROVIDE COLOR CODED JACK FOR INTENDED USE. 0001 TYPICAL PATCH PANEL LABELING CONVENTION NO SCALE NOTES: 1. ALL LABELS SHALL BE MACHINE PRINTED. 2. LABELING CONVENTION APPLIES TO BOTH PATCH PANEL AND HORIZONTAL CABLING. 3. MULTIPLE PATCHPANELS CONTINUE SEQUENTIALLY NUMBERED PORT IDENTIFIER, I.E. PORT 1 ON SECOND PATCHPANEL WILL BE IDENTIFIED AS '0049', ETC. RACK MOUNT 48-PORT RJ-45 (8P8C) PATCH PANEL. PORT IDENTIFIER. 1 2 3 4 5 6 25 26 27 28 29 30 A B C JACK IDENTIFIER 1 001 SEQUENTIALLY NUMBERED PORT IDENTIFIER 0002 0003 0004 0005 0006 0025 0026 0027 0028 0029 0030 BUILDING LEVEL IDENTIFIER: 0 - BASEMENT 1 - 1ST FLOOR ETC. BUILDING LEVEL IDENTIFIER: 0 - BASEMENT 1 - 1ST FLOOR ETC. HORIZONTAL CABLE LABELING CONVENTION NO SCALE NOTES: 1. ALL LABELS SHALL BE MACHINE PRINTED AND SHALL WRAP COMPLETELY AROUND CABLE. 2. LABELING SHALL BE PAPER WITH THERMOPLASTIC WRAP. PATCH PANEL. 4PR UTP CABLE. 6" MAX. 8P8C RJ-45 CONNECTOR. 1 001 WALLPLATE OR BISCUIT OUTLET. 4PR UTP CABLE. 6" MAX. 8P8C RJ-45 CONNECTOR. 1 001 BUILDING LEVEL IDENTIFIER: 0 - BASEMENT 1 - 1ST FLOOR ETC. SEQUENTIALLY NUMBERED PORT IDENTIFIER 1 001 1 001 BUILDING LEVEL IDENTIFIER: 0 - BASEMENT 1 - 1ST FLOOR ETC. SEQUENTIALLY NUMBERED PORT IDENTIFIER TYPICAL PATCH CABLE LABELING CONVENTION NO SCALE NOTES: 1. ALL LABELS SHALL BE MACHINE PRINTED AND SHALL WRAP COMPLETELY AROUND CABLE. 2. LABELING SHALL BE PAPER WITH THERMOPLASTIC WRAP. 01 001 TO PATCH PANEL. TO LAN SWITCH. 4PR UTP CABLE. 8P8C RJ-45 CONNECTOR. 6" MAX. 6" MAX. LAN SWITCH # PORT # 01 001 001 SEQUENTIALLY NUMBERED PATCH PANEL PORT IDENTIFIER 001 8P8C RJ-45 CONNECTOR. 1 001 A B JACK 'A' PORT # JACK 'B' PORT # JACK IDENTIFIER 2-PORT SURFACE MOUNT BISCUIT JACK. TYPICAL BISCUIT JACK LABELING CONVENTION NO SCALE NOTES: 1. ALL LABELS SHALL BE MACHINE PRINTED. 2. LABELING CONVENTION APPLIES TO BOTH FACEPLATE AND CABLING. 3. PROVIDE COLOR CODED JACK FOR INTENDED USE. 1 001 SEQUENTIALLY NUMBERED PORT IDENTIFIER BUILDING LEVEL IDENTIFIER: 0 - BASEMENT 1 - 1ST FLOOR ETC. 4PR UTP CABLE. OUTLET PATHWAY DIAGRAM - DRYWALL PARTITION OUTLET ASSEMBLY. CONDUIT STUBBED ABOVE ACCESSIBLE CEILING. 6" RADIUS MINIMUM CONDUIT SWEEP. FINISHED FLOOR. WALL SURFACE (GYP BD). ACCESSIBLE CEILING. PROVIDE INSULATED BUSHING ON END OF CONDUIT. ADHERE TO ONE OF THE FOLLOWING METHODS FOR ROUTING CONDUIT FROM OUTLET: 1. STUB INTO SPACE ABOVE ACCESSIBLE CEILING; 2. ROUTE TO NEAREST ARLINGTON LOOP PATHWAY; 3. ROUTE TO SERVING IDF/MDF. NO SCALE FIRE-RATED PATHWAY DIAGRAM NO SCALE FIRE-RATED PARTITION. FIRE-RATED PATHWAY BY HILTI OR STI. HORIZONTAL CABLING. J-HOOK, ARLINGTON LOOP OR CABLE TRAY. 12"12" FINISHED CEILING. A B C D E F G H J K L M Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title TECHNOLOGY DIAGRAMS E-600 09/21/18 RF DISTRIBUTION MODULE / SPLITTER, BY OTHERS. AC DUAL POWER MODULE. (LEVITON 47605-DP) NETGEAR GS-105PE PoE-POWERED 5-PORT SWITCH (10/100/1000 OR EQUIVALENT. PROVIDE LEVITON MOUNTING BRACKETS FOR INSTALLATION INTO MEDIA CABINET. STRUCTURED MEDIA CENTER, INCLUDE FLUSH MOUNT COVER. (LEVITON 47605-28W) OR EQUIVALENT. 12-PORT CATEGORY 6 STRUCTURED MEDIA PANEL, FOR VOICE/DATA. (LEVITON 476TM-612) STRUCTURED MEDIA CABINET ELEVATION PLAN SYMBOL: 1"C FROM SERVING TELECOM ROOM/IDF. CEILING SURFACE MOUNT CAMERA DIAGRAM 3/4"C. HOMERUN TO NEAREST CABLETRAY OR TELECOM ROOM. 4PR CAT6 UTP CABLE (YELLOW). TERMINATE WITH MALE 8P8C PLUG. PROVIDE 36" SLACK COILED AT PATCHPANEL. HOMERUN TO CCTV PATCHPANEL IN SERVING IDF. CAMERA BACKBOX. FINISHED SURFACE. CAMERA. PLAN SYMBOL:NO SCALE A B Sheet Number Date:VAIL, COLORADO953 S. Frontage Rd. West Vail, Colorado 81657 tel: 970.476.1147 gpslarchitects.com SOLAR VAIL501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCH24 JUL. 2018 ALL SHEETS VE PERMIT ISSUE ALBUQUERQUE | AVON | DENVER | FORT COLLINS 303.278.3820 www ˛bgbuildingworks˛com Project No. 9911.00 Copyright 2018 Sheet Title TECHNOLOGY DIAGRAMS E-601 09/21/18