HomeMy WebLinkAboutB18-0096_Fire Protection Approved Plans_1537563490.pdfPROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
DRAWN BY: NWR
CHECKED BY: KLMS O L A R V A I L V A I L , C OL OR A D O18-109
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
35% DESIGN SET02-13-2018
FIRE PROTECTION CONTRACTOR
501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-24-2018
F.D. CYCLE 2 REV.8-27-2018
FA-0.1
1
FIRE ALARM
DETAILS AND
NOTES
MOUNTING HEIGHTS
TYPICAL DEVICE
FIRE ALARM SYSTEM
SCOPE
THE PURPOSE OF THIS PROJECT IS TO PROVIDE A FIRE
ALARM SYSTEM FOR A NEW BUILDING. REQUIRED
DETECTION WILL BE PROVIDED AND NOTIFICATION WILL BE
PROVIDED THROUGHOUT. THE ELEVATOR IS A TRACTION
ELEVATOR AND THE SHAFT IS NOT SPRINKLERED.
FIRE DEPARTMENT
OCCUPANCY GROUP:
5
CODE ANALYSIS
NUMBER OF STORIES:
SYSTEM TYPE:
VAIL FIRE & EMERGENCY SERVICES
Notification
XX Actuate Zone Visual IndicatorSilence Horns & StrobesActuate Supervisory Alarm Visual IndicatorAct uate Trouble Alarm Visual IndicatorActuate Trouble Alarm Audible SounderXX Actuate General Alarm Audible SounderActuate General Alarm Visual IndicatorActuate Supervisory Alarm Audible Sounder1 Pull Station
System Inputs
X
X
XX
X
X
X
XXXX
5
6
7
2
4
12
9
10
8
Open Circuit
Ground Fault
Low Battery
AC Power Failure (1 Hour Delay)
Communication Fault
Silence feature at FACP
Notification Appliance Short CircuitTransmit Point ID & Condition To Supervisory StationControl Panel
Annunciation
13 Actuate Interior Horn/StrobesX
XX XX Smoke DetectorX
14
Water Flow Switch/Pressure Switch
Sprinkler Tamper SwitchActuate Exterior Horn/StrobeX XX XX X
XX
X X XX Elevator Shaft Smoke
Safety
Control
FACP SEQUENCE OF OPERATIONS
Recall
El evator Cab
to Primar y FloorRecall Elevator Cab to Alternate FloorShunt Trip Elevator PowerIlluminate
Fireman's Hat15
16
17
First Floor Elevator Lobby Smoke Detector
Alternate Floor Elevator Lobby Smoke Detector
X X XX X
X X XX X
X
X
S-1, S-2, B, A-3, R-2
X
X
X
X
X
XX
X
ADDRESSABLE
20
X
ADDITIONAL BID NOTES
1. THIS FIRE ALARM DESIGN IS FOR BID PURPOSES. IT IS
INTENDED THAT PRICING SUBMITTED SHALL INCLUDE
EVERYTHING REQUIRED TO PROVIDE A COMPLETE
AND OPERATIONAL SYSTEM TO THE OWNER,
WHETHER INDICATED ON THESE DRAWINGS OR NOT.
2. ALL WORK SHALL COMPLY WITH ALL APPLICABLE
FEDERAL, STATE, AND LOCAL CODES, LAWS, ACTS,
ORDINANCES, AND ALL AUTHORITIES HAVING
JURISDICTION.
3. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
ASPECTS OF JOBSITE SAFETY; THE AHJ AND
ENGINEER ASSUME NO RESPONSIBILITY OR RISK FOR
MEANS AND METHODS USED BY THE CONTRACTOR
FOR INSTALLING WORK DEPICTED ON THESE PLANS.
4. COORDINATE INSTALLATION WITH BUILDING
ELEMENTS AND OTHER TRADES. ALL PIPING SHALL BE
CONCEALED UNLESS APPROVED BY THE PROJECT
ARCHITECT.
5. AHJ SHALL DETERMINE FINAL LOCATION FOR FIRE
ALARM PANEL.Shut Down Associated Air Handli ng Uni tNFPA 72 2010
INTERNATIONAL BUILDING CODES 2015
XX Flash Fireman's HatX
Dwelling Unit Smoke DetectorXX X X
CO DetectorXX X X
GENERAL NOTES
1. ALL UNITS HAVE FLAT CEILINGS WITH NO
CEILING FANS.
2. ALL UNIT SMOKE DETECTORS TO BE
EQUIPPED WITH SOUNDER BASE.
X XX
X Activate Notification in UnitX
11
Low AirXX X
RES
18 2-Way Communication System
19
XX
XX X
X
3 Duct DetectorXX X X
09/21/18
LEVEL P FIRE ALARM FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
DRAWN BY: NWR
CHECKED BY: KLMS O L A R V A I L V A I L , C OL OR A D O18-109
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
35% DESIGN SET02-13-2018
FIRE PROTECTION CONTRACTOR
501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-24-2018
F.D. CYCLE 2 REV.8-27-2018
FA-1.1
2
LEVEL P
FIRE ALARM PLAN
09/21/18
LEVEL 1 FIRE ALARM FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
DRAWN BY: NWR
CHECKED BY: KLMS O L A R V A I L V A I L , C OL OR A D O18-109
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
35% DESIGN SET02-13-2018
FIRE PROTECTION CONTRACTOR
501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-24-2018
F.D. CYCLE 2 REV.8-27-2018
FA-1.2
3
LEVEL 1
FIRE ALARM PLAN
09/21/18
LEVEL 2 FIRE ALARM FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
DRAWN BY: NWR
CHECKED BY: KLMS O L A R V A I L V A I L , C OL OR A D O18-109
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
35% DESIGN SET02-13-2018
FIRE PROTECTION CONTRACTOR
501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-24-2018
F.D. CYCLE 2 REV.8-27-2018
FA-1.3
4
LEVEL 2
FIRE ALARM PLAN
09/21/18
LEVEL 3 FIRE ALARM FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
DRAWN BY: NWR
CHECKED BY: KLMS O L A R V A I L V A I L , C OL OR A D O18-109
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
35% DESIGN SET02-13-2018
FIRE PROTECTION CONTRACTOR
501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-24-2018
F.D. CYCLE 2 REV.8-27-2018
FA-1.4
5
LEVEL 3
FIRE ALARM PLAN
09/21/18
LEVEL 4 FIRE ALARM FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET 15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
DRAWN BY: NWR
CHECKED BY: KLMS O L A R V A I L V A I L , C OL OR A D O18-109
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
35% DESIGN SET02-13-2018
FIRE PROTECTION CONTRACTOR
501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-24-2018
F.D. CYCLE 2 REV.8-27-2018
FA-1.5
6
LEVEL 4
FIRE ALARM PLAN
09/21/18
ROOF FIRE ALARM FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
DRAWN BY: NWR
CHECKED BY: KLMS O L A R V A I L V A I L , C OL OR A D O18-109
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
35% DESIGN SET02-13-2018
FIRE PROTECTION CONTRACTOR
501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-24-2018
F.D. CYCLE 2 REV.8-27-2018
FA-1.6
7
ROOF
FIRE ALARM PLAN
09/21/18
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
Solar Vail_FP.dwg
35% DESIGN SET
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
2-13-2018
DRAWN BY: NWR
CHECKED BY:V A I L , COL OR A DO VERITAS: 18-109
FIRE PROTECTION CONTRACTOR
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
S O L A R V A IL FP0.1
1
FIRE SPRINKLER PLAN
COVER SHEET
PROJECT SCOPE NARRATIVE
THE SCOPE OF THIS PROJECT IS TO PROVIDE NEW FIRE SPRINKLER
SYSTEMS FOR A NEW BUILDING. PROVIDE DRY SYSTEM TO PROTECT
MECHANICAL UNITS ONLY IN ATTIC PER NFPA 13R 2016 ED. 6.6.6.
DESIGN CRITERIA PER NFPA 13R 2016 ED., 2012 I-CODES AND LOCAL AHJ
REQUIREMENTS.
QUICK RESPONSE SPRINKLER HEADS
MAX SPACING PENDENTS = 225 SQ. FT.
MAX SPACING ABOVE CEILING UPRIGHTS = 16'-0" x 16'-0"
MAX SPACING UPRIGHTS = 225 SQ. FT.
MAX SPACING EXTENDED COVERAGE PENDENTS= 20'-0" x 20'-0"
MAX SPACING SIDEWALL = 168 SQ. FT.
MAX SPACING SIDEWALL (ORDINARY HAZARD) = 16'-0" x 20'-0"
MAX SPACING UPRIGHTS (ORDINARY HAZARD) = 130 SQ. FT.
FIRE PROTECTION SYMBOL LEGEND
XX'-X"
X
PIPE PLUG
PIPE HANGER
PIPE COUPLING
PIPE ELEVATION
HYDRAULIC NODE
HORN STROBE
PIPE RISE
SYSTEM RISER
PIPE CAP
PIPE REDUCER
2-WAY EARTHQUAKE BRACE
PENDENT
HEAD ELEVATION
DROP PENDENT
FIRE DEPT CONNECTION
CONTROL VALVE
AUXILARY DRAIN
SHEET NOTE
PIPE DROP TC INSP. TEST CONN.
X
SIDE WALL
X'-X"
BID NOTES
1. THIS DESIGN IS FOR BID PURPOSES. IT IS INTENDED THAT
PRICING SUBMITTED SHALL INCLUDE EVERYTHING
REQUIRED TO PROVIDE A COMPLETE AND OPERATIONAL
SYSTEM TO THE OWNER, WHETHER INDICATED ON THESE
DRAWINGS OR NOT.
2. ALL WORK SHALL COMPLY WITH ALL APPLICABLE
FEDERAL, STATE, AND LOCAL CODES, LAWS, ACTS,
ORDINANCES, AND ALL AUTHORITIES HAVING
JURISDICTION.
3. THIS CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
ASPECTS OF JOBSITE SAFETY; THE GOVERNMENT AND
ENGINEER ASSUME NO RESPONSIBILITY OR RISK FOR
MEANS AND METHODS USED BY THE CONTRACTOR FOR
INSTALLING WORK DEPICTED ON THESE PLANS.
4. COORDINATE PIPING AND SPRINKLER INSTALLATION WITH
BUILDING ELEMENTS AND OTHER TRADES. ALL PIPING
SHALL BE CONCEALED UNLESS APPROVED BY THE
PROJECT ARCHITECT.
5. THE FIRE PROTECTION CONTRACTORS WORK SHALL
BEGIN AT A 6 X 9 FLANGE SPIGOT INSIDE THE BUILDING.
THIS FLANGE SPIGOT SHALL BE TWO HOLED AND LEVEL.
THIS FLANGE SPIGOT SHALL BE PROVIDED BY
UNDERGROUND CONTRACTOR. TEST CERTIFICATES
SHALL BE PROVIDED TO THE FP CONTRACTOR.
6. ALL AREAS ARE LIGHT HAZARD EXCEPT FOR STORAGE,
ELECTRICAL, AND MECHANICAL AREAS WHICH SHALL BE
ORDINARY HAZARD 1. PARKING GARAGE SHALL BE
ORDINARY HAZARD 1.
7. PROVIDE TEST CONNECTION FOR FULL FORWARD FLOW
TEST OF BACKFLOW PREVENTER AT SYSTEM DEMAND.
8. CONTRACTOR TO EXAMINE ALL CEILING SPACES TO
CONFIRM NFPA 13 GUIDELINES FOR INSTALLATION OF OR
OMISSION OF SPRINKLERS IN INTERSTITIAL SPACES.501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-27-2018
09/21/18
LEVEL P FIRE PROTECTION FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
Solar Vail_FP.dwg
35% DESIGN SET
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
2-13-2018
DRAWN BY: NWR
CHECKED BY:V A I L , COL OR A DO VERITAS: 18-109
FIRE PROTECTION CONTRACTOR
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
S O L A R V A ILFP1.1
2
LEVEL P
FIRE SPRINKLER PLAN501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-27-2018
09/21/18
LEVEL 1 FIRE PROTECTION FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET 15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
Solar Vail_FP.dwg
35% DESIGN SET
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
2-13-2018
DRAWN BY: NWR
CHECKED BY:V A I L , COL OR A DO VERITAS: 18-109
FIRE PROTECTION CONTRACTOR
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
S O L A R V A IL FP1.2
3
LEVEL 1
FIRE SPRINKLER PLAN501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-27-2018
09/21/18
LEVEL 2 FIRE PROTECTION FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
Solar Vail_FP.dwg
35% DESIGN SET
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
2-13-2018
DRAWN BY: NWR
CHECKED BY:V A I L , COL OR A DO VERITAS: 18-109
FIRE PROTECTION CONTRACTOR
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
S O L A R V A IL FP1.3
4
LEVEL 2
FIRE SPRINKLER PLAN501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-27-2018
09/21/18
LEVEL 3 FIRE PROTECTION FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
Solar Vail_FP.dwg
35% DESIGN SET
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
2-13-2018
DRAWN BY: NWR
CHECKED BY:V A I L , COL OR A DO VERITAS: 18-109
FIRE PROTECTION CONTRACTOR
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
S O L A R V A IL FP1.4
5
LEVEL 3
FIRE SPRINKLER PLAN501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-27-2018
09/21/18
LEVEL 4 FIRE PROTECTION FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET15 NORTH
LOCATION OF
DRY PIPE
VALVE FOR
ATTIC SYSTEM
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
Solar Vail_FP.dwg
35% DESIGN SET
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
2-13-2018
DRAWN BY: NWR
CHECKED BY:V A I L , COL OR A DO VERITAS: 18-109
FIRE PROTECTION CONTRACTOR
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
S O L A R V A ILFP1.5
6
LEVEL 4
FIRE SPRINKLER PLAN501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-27-2018
09/21/18
ROOF FIRE PROTECTION FLOOR PLAN
SCALE: 1/8" = 1'-0"
10 5 0 21 FEET15 NORTH
PROFESSIONAL SEAL
DATE: 3-26-2018
REVISIONS:
PROJECT NUMBER:
ISSUE:
Solar Vail_FP.dwg
35% DESIGN SET
COPYRIGHT 2018
This document is an instrument of service, and
as such, remains the property of the Engineer.
Permission for use of this document is limited
and can be extended only by written agreement
with Veritas Fire Engineering, Inc.
OF 7
2-13-2018
DRAWN BY: NWR
CHECKED BY:V A I L , COL OR A DO VERITAS: 18-109
FIRE PROTECTION CONTRACTOR
12364 W. Alameda Pkwy Ste. 135
Lakewood, Colorado 80228
303-985-3300 Office
303-985-5594 Fax
www.veritasfire.com
S O L A R V A IL FP1.6
7
ROOF
FIRE SPRINKLER PLAN501 NORTH FRONTAGE ROAD WESTLOT 8B, BLK 2, VAIL POTATO PATCHPERMIT ISSUE3-26-2018
PERMIT RESUBMIT7-27-2018
09/21/18