HomeMy WebLinkAboutAssembly listing.pdf STANDARDS USG Durock"cement board exceeds ANSI standards for cementitious backer units(CBU).See ANSI A118.9 for test
methods and specifications for CBU and ANSI A1O8.11 for interior installation of CBU.Exceeds industry standards
as an exterior substrate for exterior finishes.Exceeds ASTM C1325 standards for nonasbestos fiber-mat reinforced
cementitious backer units.
0r0 .
fl
PARTITIO1• prg.1.1 ilric-0.ku•tRa
suiinuHrn Non-Load Bearing,Steel Framed -. Acoustical Performance ``��..
Construction Detail Description Test Number STC Test Number q
—1,4,, 1116Ii Sr 1(1(1( 'if1(QI lnitl l( I/2"US60urn k`Brand cementboard 0433 of
1 11Jillli111 li 111111iiliii1 3 1/2"20-gaugesleelstudsl6"o.c .
in ilill�lJ.ivSA1SISL4 -3'ROXULminera!wool AFB
.,__ry I ,;,,- •5/8"USG Sheetrock°Brand Firecode`Gypsum Paneis.one side
Twp-Hour Fire-RatedConstruction Non-Load-Bearing,Steel Framed Acoustical Performance
Construction Detail Description Test Number STC Test Number
•I/2"USG Burock"Brand cement board and1/4"ceramic the 0443 56 SA-851016
.; •Base layer1/2"USG Sheetrock'Brand Firecode'C Gypsum Based on alternate
tit)fflT(I07-1T1-Tl1T1TT(TfTF Panels design
6i/a iiiiiiiiiiiititi 11111IIIil11 -3-5/8"20-gauge steelstuds is.,
11}(Ut i{It It 11,II J{It IIJI)(Ri!- 3"Therma0bur,SAFE;,,,
-Face layerjolnislaped 58 SA451028
•Alturnatedesign two la yersl/2"USG Sheetrock'Brand
Firecode'C gypsum panels.oneside
One-Hour Fire-Rated Construction Chase Walls,SteelFremetl Acoustical Performance.
Construction Detail Description Test Number STC Test Number
•Face layer l/2"USG Durock`Brand cement board UL Des U473
T •Base layer 5/B"uSG Sheetrock'Brand Firecode'gypsum
5I Innri of)e5rrIg15n(lf5( panels or sheathing,or USG Fiberock'panels
ililiti\li1110t 111111 11 11111. -3-1/2"20-gaugestructuraistuds l6"o.c,
t llttii)iit)tV1R11)t,() il i -3"mineralwoolbett
•5/8"USG Sheetrock'Brand Firecode'Gypsum Panels opposite side
One-Hour Fire-RatedConstruction Load-Bearing,Wood Framed Acoustical Performance
Construction Detail Description Test Number STC Test Number
lfl 1(1(1(1 1(1(17 11 •1/2"USG Burock•Brand cement board andl/4"ceramic file UL Des U329 37 USG-840404
( 1f f,1 -2x4 wood studs l6"o.c.
5" 1100010 11111111110 _3-1/2'Thermahber'SAFB'"
t It J.R ii it r ` )1)ill)(l(= -Joints aped
•Alternate design 5/B"USG Sheetrock'Brand Firecode`gypsum 40 USG-830314
paneK one side
i ..... USGBe ock`Branticementboard 0303
5/ nr if1111T(TPA 1firy)f 1lTr` -Base layerl5/32"plywood
1111111nnl Illi riiiiiII -2x4woodstud516"o.e.
ii ll Ii ii h II{ t f itll II t ji -3"Thermahber'SAFB-
-Joints taped and treated '
•5/8"USG Sheetrock°Brand Firecodegyps um peneis,other
side
cism Chase Walls,Steel Framed Acoustical Performance
Construction Detail Description Test Number STC Test Number
• ( •1/2"056 Durock'Brand cement heartland l/4"ceramic tile WHI-49S-0505 50 SA-840523
i1;11111i� 1 ...i1 i 1 -Two rows 2 x4 wood studs IC'o.con 2 x8 common plate 0508
1 1 !!i -3-1/2"Thermafber°SAFE'^both cavities
9 - -4Hfl Hid}�}, Joints taped
I iliiliiiiiii ii7111i11 -Load-bearing up to 50%allowabledesign load
ROOF/CEILINGS One-Hour Fire-Rated Construction Steel Truss Acoustical Performance
Construction Detail Description Test Number STC Test Number
•5/8"USGSheetrock'Brand Firecode•gypsum panels UL Des P521,
-PC-I channels or equivalent P525,527,529
-Joints finished
-Steel roofdeck
-Steel truss 48"o.c.
•Roofcovering and roof insulation over1/2"USG Durock'Brand
cement boardorl/2"USG Sheetrock'Brand gypsum panels
USG Durock'Brand Cement Board Systems 14