HomeMy WebLinkAboutload calcs_24.pdf 5075 Ute Lane
Existing Load Calculation 6/13/17:
3,330 sq.ft. @ 3VA 9,990 VA
Kitchen appliance X 2 3,000 VA
Dishwasher 1,200 VA
Disposal 1,200 VA
Refrigerator 1,200 VA
Microwave 1,200 VA
Range 10,000 VA
Washer 1,500 VA
Dryer 5,000 VA
Steamer 12,000 VA
General Load Sub-Total 46,290 VA
1" 10kVA @ 100% 10,000 VA
Remainder @ 40% 14,516 VA
Total Net General Load 24,516 VA
Boiler and pumps @ 100% 1,500 VA
Heat Tape @ 100% 3,000 VA
Total 29,016 VA
Calculated Load for Service 29,016 VA/240 volts = 121 Amps
Existing service size 200Amps
1
5075 Ute Lane
Proposed Load Calculation 6/13/17:
5605 sq.ft. @ 3VA 16,815 VA
Kitchen appliance X 2 3,000 VA
Dishwasher 1,200 VA
Disposal 1,200 VA
Refrigerator 1,200 VA
Microwave 1,200 VA
Range 10,000 VA
Washer x 2 3,000 VA
Dryer x2 10,000 VA
Hot Tub 10,000 VA
Steamer 12,000 VA
General Load Sub-Total 69,615 VA
1st 10kVA @ 100% 10,000 VA
Remainder @ 40% 23,846 VA
Total Net General Load 33,846 VA
Boiler and pumps @ 100% 3,000 VA
Heat Tape @ 100% 6,000 VA
Total 42,846 VA
Calculated Load for Service 42,846 VA/ 240 volts= 179 Amps
Existing service size 200Amps
Owner would like a New 320Amp Service
1