HomeMy WebLinkAboutLoad Calcs_31.pdf Double M Inc Date: 5-26-16 P.O. Box 1462 Gypsum, CO 81637 (970) 376-4862 Residential Electrical Load Calculations Owner: Fischer Residence Address: 2636 Davos Trail General Lighting Load Square footage: 4100 General lighting load: 12300 Watts Small appliance: 3000 Watts Laundry Circuit: 3000 Watts Lighting Load Subtotal: 18300 Watts First 3000 @ 100%: 3000 Watts 3001 watts to 120,000 watts @ 35%: 5355 Watts Over 120,000 watts @ 25%: Watts Lighting Load Total: 8355 Watts Cooking Equipment Loads Range: Load @ 100% 10400 Watts Dryer load Dryer: Load @ 100% 5000 Watts Fixed Appliance Load Dishwasher: 1050 Watts Disposal: 600 Watts Elevator: 7200 Watts Microwave: 1500 Watts Range Hood: 360 Watts Refrigerator: 1920 Watts Jacuzzi Tub: 1500 Watts Spa: 9600 Watts Freezer: 720 Watts Compressor: 4800 Watts Car charger: 9600 Watts Garage Door: 720 Watts Total: 39570 Watts Less than 4 appliance at 100%: Watts More than 4 appliances at 75%: 29677.5 Watts Total: 29677.5 Watts Heating or A/C load which ever is larger Heating unit: 1440 Watts A/C unit: Watts Heat tape: 5000 Watts Largest load: 6440 Load @ 100% 6440 Watts Largest Motor Load 4800 Watts @ 25%: 1200 Watts Total load: 61072.5 Watts Total amp draw: 254.46875 Amps Service Size: 400 Amps