HomeMy WebLinkAboutE18-0159_Shapiro Residence Load Calc_1537902893.pdf 7roF \
Job Name: Shapiro Residence .,Q
Job Address:4425 Glen Falls a
i,
09/25/18
Residential Load Calculation - Existing Dwelling Unit
NEC Article 220.83(A)
General Lighting #of Circ. Or Sq Ft Total VA
Existing Livable SF @ 3VA/Sq Ft 3484 10452
Additional Livable SF @3VA/SqFt 245 735
Small App. Circuits @ 1500VA each 2 3000
Laundry Circuit @ 1500 VA each 1 1500
Total G.L. 15687
Appliances #of App. VA each Total VA
Disposal 1 1200 1200
Dishwasher 1 1300 1300
Microwave 1 950 950
Refrigerators 1 996 996
Ex Hood 1 400 400
Gas Cooktop 1 300 300
Wine Chiller 0 400 0
Elevator 0 6960 0
Insta Hot 1 1300 1300
Humidifier 0 5500 0
Jetted Tub 0 1400 0
Steam Shower 0 9600 0
Hot Tub 1 9600 9600
Total App 16046
Clothes Dryer #of Dryers VA Each Total VA
1 6240 6240
7roF \4/e
iiia.15.%
Total Dryer 6240
tk
Electric Cooking Appliances #of Cooking Appliances VA Each Total VA 1Q0]
Electric Range 1 9600 9600 09/25/18
Electric Oven 0 6200 0
Total Cooking 9600
Heat Total VA
Heat Tape 3840
Electric Heat 156
Boiler 1440
Total Heat 5436
Air Conditioning
Total VA
Condenser 0
Air Handler 0
Ductless 0
Total AC 0
X001 OF I/4/
i riC
ec
..11-1Q1013
09/25/18
Demand Factors VA
Total General Lighting 15687
Appliances 16046
Dryer Load 6240
Total Electric Cooking Load 9600
Total Heat or AC (Larger) 5436
Total Loads 53009
Demand Factors
First 8KVA @ 100% 8000
Remainder @ 40% 18004
Total Connected Load in VA 26004
Min. Service Amps @ 240V 108