HomeMy WebLinkAboutE18-0159_Shapiro Residence Load Calc_1537902893.pdf 7roF \ Job Name: Shapiro Residence .,Q Job Address:4425 Glen Falls a i, 09/25/18 Residential Load Calculation - Existing Dwelling Unit NEC Article 220.83(A) General Lighting #of Circ. Or Sq Ft Total VA Existing Livable SF @ 3VA/Sq Ft 3484 10452 Additional Livable SF @3VA/SqFt 245 735 Small App. Circuits @ 1500VA each 2 3000 Laundry Circuit @ 1500 VA each 1 1500 Total G.L. 15687 Appliances #of App. VA each Total VA Disposal 1 1200 1200 Dishwasher 1 1300 1300 Microwave 1 950 950 Refrigerators 1 996 996 Ex Hood 1 400 400 Gas Cooktop 1 300 300 Wine Chiller 0 400 0 Elevator 0 6960 0 Insta Hot 1 1300 1300 Humidifier 0 5500 0 Jetted Tub 0 1400 0 Steam Shower 0 9600 0 Hot Tub 1 9600 9600 Total App 16046 Clothes Dryer #of Dryers VA Each Total VA 1 6240 6240 7roF \4/e iiia.15.% Total Dryer 6240 tk Electric Cooking Appliances #of Cooking Appliances VA Each Total VA 1Q0] Electric Range 1 9600 9600 09/25/18 Electric Oven 0 6200 0 Total Cooking 9600 Heat Total VA Heat Tape 3840 Electric Heat 156 Boiler 1440 Total Heat 5436 Air Conditioning Total VA Condenser 0 Air Handler 0 Ductless 0 Total AC 0 X001 OF I/4/ i riC ec ..11-1Q1013 09/25/18 Demand Factors VA Total General Lighting 15687 Appliances 16046 Dryer Load 6240 Total Electric Cooking Load 9600 Total Heat or AC (Larger) 5436 Total Loads 53009 Demand Factors First 8KVA @ 100% 8000 Remainder @ 40% 18004 Total Connected Load in VA 26004 Min. Service Amps @ 240V 108 Existing Service Amps 200