HomeMy WebLinkAboutDRB18-0307_approved plans_1533309667.pdfBASEMENT SOUTH
8195' - 0"
FIRST FLOOR
SOUTH
8203' - 11"
SECOND FLOOR
SOUTH
8212' - 10"
THIRD FLOOR
SOUTH
8221' - 9"
FOURTH FLOOR
SOUTH
8230' - 8"
GARAGE / UNDER POOL
TYP.1
TYP.2
TYP.1
TYP.2
7' SECURITY POOL PROTECT FENCE
TRIM
SAVE / REUSE
TRASH ROOM
EGRESS
*
*
REPAINT UNIT #513 WINDOW
AND DOOR SASH TYP
OWNER TO VERIFY
2
A506
Sim
11
A506
Sim
6
A506
Sim
11
A506
Sim
11
A506
Sim
6
A506
Sim
6
A506
Sim
11
A506
Sim
11
A506
Sim
5
A506
Sim
6
A506
Sim
6
A506
Sim
7
A505
Sim 7
A505
Sim
7
A505
Sim
9
A505
Sim
5
A507
Sim
*BEYOND
*ADD 2 X 6 TRIM @ 11/A506 TYP
DRIVE THRU
BELLY BAND
METAL ROOF W/ SNOW FENCING
REPAINT DOORS AND FRAME
2 X 6 BETWEEN SIDING AND STUCCO
*
* *
*
*
*
*
CEDAR PLANK - TO BE REMOVED
EXISTING MATERIALS
SPLIT-FACE CMU - TO REMAIN AND
BE COVERED WITH NEW SIDING
ASPHALT
SHINGLES TO
REMAIN
CEMENTIOUS LAP SIDING - 7"
EXPOSURE (MOUNTAIN SAGE - HARDIE
PLANK)¹
PROPOSED MATERIALS
CEMENTIOUS STUCCO
(CROISSANT - SHERWIN WILLIAMS)
¹
STONE¹
¹TO MATCH 100/200 BUILDING
ASPHALT SHINGLES (MATCH
EXISTING)
1. ALL EXISTING WINDOWS TO BE REPLACED, EXCEPT WHERE NOTED;
CONTRACTOR TO PROVIDE DOOR AND WINDOW SCHEDULE BASED ON
MINIMUM REDUCTION OF EXISTING OPENING DIMENSIONS AND TO VERIFY
EMERGENCY EGRESS REQUIREMENTS FOR NEW WINDOWS
2. MATERIAL COLORS TO MATCH EXISTING ON 100/200 BUILDING (STONE TO
MATCH 300/400 BUILDING)
3. EXISTING CEDAR SHAKE SIDING TO BE REMOVED
4. EXISTING SPLIT-FACE CMU TO REMAIN AND BE COVERED BY NEW MATERIALS
AS PROPOSED AND REPAIRED AS NECESSARY
5. STUCCO TO RECEIVE CONTROL JOINTS PER MFR'S RECOMMENDATION AND
PER PATTERNS INDICATED ON ELEVATIONS
6. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING GUTTERS AND
DOWNSPOUTS AND INSTALL NEW GUTTERS AND DOWNSPOUTS WHERE
NOTED AND BE PLUMB AND HORIZONTAL. RE A101
7. ALL EXISTING HEAT TAPE TO BE REPLACED; NEW HEAT TAPED INSTALLED AT
NEW GUTTERS AND DOWNSPOUTS
8. CONTRACTOR TO REMOVE AND REPLACE EXPOSED UTILITIES AS NEEDED TO
COMPLETE THE WORK IN A NEAT AND WORKMANLIKE MANNER
9. CONTRACTOR TO REMOVE AND REPLACE EXTERIOR LIGHT FIXTURES AND ADD
LIGHT AND OUTLET TO EACH UNIT DECK
10. CONTRACTOR TO CLEAN AND REPAINT ALL DECK STRUCTURE TO REMAIN
11. ALL DECKS TO BE RESURFACED WITH REDWOOD DECKING WITH NEW
FLASHING TO BE INSTALLED AT SURROUNDING WALLS AND EDGE. 1 X 6 AT
UNIT DECKS (EXCEPT AT UNIT 501). 2 X 6 AT COMMON WALKWAYS.
12. ALL EXISTING DRYER VENT TERMINATIONS TO BE REPLACED WITH SEIHO
MODEL SFB-P OR SFB AS APPROPRIATE; ALL OTHER VENT TERMINATIONS TO
BE REPLACED WITH SIMILAR SIMILAR TO MATCH 100/200 BUILDING
13. REPAIR AND PATCH EXISTING GYPSUM BOARD SHEATHING WHERE
NECESSARY WTH PLYWOOD
14. REPLACE EXTERIOR CONDUIT AS NECESSARY AND CONCEAL AS CONDITIONS
ALLOW.
15. REPLACE COMMON WALKWAYS, STAIRS AND DECK STRUCTURE PER STRUCT
ENGINEER.
16. REMOVE AND REPLACE EXISTING PAINT ON TIMBER COLUMNS AT COMMON
WALKWAYS
17. ALL EXISTING CONCRETE WALKWAYS TO REMAIN EXCEPT WHERE NOTED
18.
19.
20. ALL MOUNTING ON HARDIE PLANK SIDING TO USE STURDIMOUNT MOUNTING
BLOCKS
21. REFER TO JAMES HARDE WEBSITE FOR REQUIRED INSTALLATION GUIDELINES
(WWW.JAMESHARDIEPROS.COM) REVIEW THE INSTALLATION INSTRUCTIONS
FOR THESE CRITICAL DETAILS(A) CLEARANCE TO SMF (B) CLEARANCE TO
GRADE, CONC., AND ROOF (C) PRIMING OF SIDES, INCLUDING FIELD CUT
EDGES (D) SEALANT AT LOCATIONS AS REQ'D BY MFGR. (E) MFGR.
RECOMENDED DETAILS AT LAP
GENERAL NOTES
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
07/05/18
A204
NORTH
ELEVATIONBREAKAWAY WEST 500EXTERIOR IMPROVEMENTS1634__963 LIONS RIDGE LOOP, VAIL, CO 8167509/05/17
3/16" = 1'-0" A204
3 NORTH ELEVATION - PROPOSED
# DESCRIPTION
1 FIBER CEMENT LAP SIDING, 7" EXPOSURE - COLOR: HARDIE FACTORY-APPLIED MOUNTAIN SAGE
JH50-30 BOTH FACES - ON TYVEK BUILDING WRAP
2 CEMENTITOUS STUCCO - COLOR: SHERWIN WILLIAMS SW7716 CROISSANT - ON TYVEK BUILDING
WRAP
3 BELLY BAND - 2X10 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 VAN BUREN
BROWN
5 WINDOW TRIM - 2X6 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 HASBROUCK
BROWN - OVER VYCOR WINDOW STRIP
8 DECK RAILING - POWDER COATED METAL RAILING TO MATCH 100/200 BLDG - COLOR: BLACK
17 STONE - TO MATCH EXISTING 100/200 BUILDING
18 STUCCO JOINTS TO MATCH 100/200 BUILDING
KEYNOTE LEGEND
DRB
APPROVED
8/1/2018 12:00:00
AM
FIRST FLOOR
SOUTH
8203' - 11"
SECOND FLOOR
SOUTH
8212' - 10"
THIRD FLOOR
SOUTH
8221' - 9"
FOURTH FLOOR
SOUTH
8230' - 8"
FIRST LEVEL
NORTH
8202' - 9"
SECOND LEVEL
NORTH
8213' - 2 1/4"
THIRD FLOOR
NORTH
8222' - 1 1/4"
2
A505
NEW RAILING WHERE
NONE CURRENTLY
EXISTS
TYP.2
TYP.1
TYP.17
NEW TRASH
ENCLOSURE TO
REPLACE EXIST.
NEW CORREGATED
METAL TRASH DOOR -
BARN DOOR STYLE
MOCK UP WINDOW / SAVE
INFILL W/ WOOD TRIM TO BELLY BAND
* *
11
A506
Sim
11
A506
Sim
11
A506
Sim
2
A506
Sim
1
A506
Sim
2
A506
Sim
A507
6 Sim
A505
11 Sim
6
A506
Sim
11
A506
Sim
7
A505
Sim
4
1. ALL EXISTING WINDOWS TO BE REPLACED, EXCEPT WHERE NOTED;
CONTRACTOR TO PROVIDE DOOR AND WINDOW SCHEDULE BASED ON
MINIMUM REDUCTION OF EXISTING OPENING DIMENSIONS AND TO VERIFY
EMERGENCY EGRESS REQUIREMENTS FOR NEW WINDOWS
2. MATERIAL COLORS TO MATCH EXISTING ON 100/200 BUILDING (STONE TO
MATCH 300/400 BUILDING)
3. EXISTING CEDAR SHAKE SIDING TO BE REMOVED
4. EXISTING SPLIT-FACE CMU TO REMAIN AND BE COVERED BY NEW MATERIALS
AS PROPOSED AND REPAIRED AS NECESSARY
5. STUCCO TO RECEIVE CONTROL JOINTS PER MFR'S RECOMMENDATION AND
PER PATTERNS INDICATED ON ELEVATIONS
6. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING GUTTERS AND
DOWNSPOUTS AND INSTALL NEW GUTTERS AND DOWNSPOUTS WHERE
NOTED AND BE PLUMB AND HORIZONTAL. RE A101
7. ALL EXISTING HEAT TAPE TO BE REPLACED; NEW HEAT TAPED INSTALLED AT
NEW GUTTERS AND DOWNSPOUTS
8. CONTRACTOR TO REMOVE AND REPLACE EXPOSED UTILITIES AS NEEDED TO
COMPLETE THE WORK IN A NEAT AND WORKMANLIKE MANNER
9. CONTRACTOR TO REMOVE AND REPLACE EXTERIOR LIGHT FIXTURES AND ADD
LIGHT AND OUTLET TO EACH UNIT DECK
10. CONTRACTOR TO CLEAN AND REPAINT ALL DECK STRUCTURE TO REMAIN
11. ALL DECKS TO BE RESURFACED WITH REDWOOD DECKING WITH NEW
FLASHING TO BE INSTALLED AT SURROUNDING WALLS AND EDGE. 1 X 6 AT
UNIT DECKS (EXCEPT AT UNIT 501). 2 X 6 AT COMMON WALKWAYS.
12. ALL EXISTING DRYER VENT TERMINATIONS TO BE REPLACED WITH SEIHO
MODEL SFB-P OR SFB AS APPROPRIATE; ALL OTHER VENT TERMINATIONS TO
BE REPLACED WITH SIMILAR SIMILAR TO MATCH 100/200 BUILDING
13. REPAIR AND PATCH EXISTING GYPSUM BOARD SHEATHING WHERE
NECESSARY WTH PLYWOOD
14. REPLACE EXTERIOR CONDUIT AS NECESSARY AND CONCEAL AS CONDITIONS
ALLOW.
15. REPLACE COMMON WALKWAYS, STAIRS AND DECK STRUCTURE PER STRUCT
ENGINEER.
16. REMOVE AND REPLACE EXISTING PAINT ON TIMBER COLUMNS AT COMMON
WALKWAYS
17. ALL EXISTING CONCRETE WALKWAYS TO REMAIN EXCEPT WHERE NOTED
18.
19.
20. ALL MOUNTING ON HARDIE PLANK SIDING TO USE STURDIMOUNT MOUNTING
BLOCKS
21. REFER TO JAMES HARDE WEBSITE FOR REQUIRED INSTALLATION GUIDELINES
(WWW.JAMESHARDIEPROS.COM) REVIEW THE INSTALLATION INSTRUCTIONS
FOR THESE CRITICAL DETAILS(A) CLEARANCE TO SMF (B) CLEARANCE TO
GRADE, CONC., AND ROOF (C) PRIMING OF SIDES, INCLUDING FIELD CUT
EDGES (D) SEALANT AT LOCATIONS AS REQ'D BY MFGR. (E) MFGR.
RECOMENDED DETAILS AT LAP
GENERAL NOTES
CEDAR PLANK - TO BE REMOVED
EXISTING MATERIALS
SPLIT-FACE CMU - TO REMAIN AND
BE COVERED WITH NEW SIDING
ASPHALT
SHINGLES TO
REMAIN
CEMENTIOUS LAP SIDING - 7"
EXPOSURE (MOUNTAIN SAGE - HARDIE
PLANK)¹
PROPOSED MATERIALS
CEMENTIOUS STUCCO
(CROISSANT - SHERWIN WILLIAMS)
¹
STONE¹
¹TO MATCH 100/200 BUILDING
ASPHALT SHINGLES (MATCH
EXISTING)
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
07/05/18
A205
WEST
ELEVATIONBREAKAWAY WEST 500EXTERIOR IMPROVEMENTS1634__963 LIONS RIDGE LOOP, VAIL, CO 8167509/05/17
3/16" = 1'-0"A205
2 WEST ELEVATION -PROPOSED
# DESCRIPTION
1FIBER CEMENT LAP SIDING, 7" EXPOSURE - COLOR: HARDIE FACTORY-APPLIED MOUNTAIN SAGE
JH50-30 BOTH FACES - ON TYVEK BUILDING WRAP
2CEMENTITOUS STUCCO - COLOR: SHERWIN WILLIAMS SW7716 CROISSANT - ON TYVEK BUILDING
WRAP
3BELLY BAND - 2X10 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 VAN BUREN
BROWN
5WINDOW TRIM - 2X6 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 HASBROUCK
BROWN - OVER VYCOR WINDOW STRIP
8DECK RAILING - POWDER COATED METAL RAILING TO MATCH 100/200 BLDG - COLOR: BLACK
17STONE - TO MATCH EXISTING 100/200 BUILDING
18STUCCO JOINTS TO MATCH 100/200 BUILDING
KEYNOTE LEGEND
PROPOSED CORREGATED MATERIAL
DRB
APPROVED
8/1/2018 12:00:00
AM
BASEMENT SOUTH
8195' - 0"
FIRST FLOOR
SOUTH
8203' - 11"
SECOND FLOOR
SOUTH
8212' - 10"
THIRD FLOOR
SOUTH
8221' - 9"
FOURTH FLOOR
SOUTH
8230' - 8"
FIRST FLOOR
EAST
8209' - 0"
SECOND FLOOR
EAST
8217' - 11"
THIRD FLOOR
EAST
8226' - 10"
2
A505
TYP.3
LOWER DOOR BEING REPLACED
WITH FIXED WINDOW. UPPER
WINDOW IS MULLED TO THE
DOOR AND WILL NEED TO BE
REPLACED. NOTIFY OWNER
SEE D1/A207
HAVE TO REPLACE.
DOES NOT MATCH.
NOTIFY OWNERA506
7 Sim
A506
2 Sim
A506
1 Sim
A506
7 Sim
EGRESS
43" HT RAILING TYP SNOW FENCE ON METAL ROOF
2
A506
Sim
7
A505
Sim
11
A506
Sim
11
A506
Sim
11
A506
Sim
11
A506
Sim
STONE CAP
NEW CORREGATED
METAL TRASH DOOR -
BARN DOOR STYLE
NEW GARAGE DOOR TRANSOM AND CLADDING TO MATCH BLDG 100 & 200
2 X 6 BETWEEN SIDING AND STUCCO
2 X 6 BETWEEN STONE AND STUCCO
A906
2
4
1. ALL EXISTING WINDOWS TO BE REPLACED, EXCEPT WHERE NOTED;
CONTRACTOR TO PROVIDE DOOR AND WINDOW SCHEDULE BASED ON
MINIMUM REDUCTION OF EXISTING OPENING DIMENSIONS AND TO VERIFY
EMERGENCY EGRESS REQUIREMENTS FOR NEW WINDOWS
2. MATERIAL COLORS TO MATCH EXISTING ON 100/200 BUILDING (STONE TO
MATCH 300/400 BUILDING)
3. EXISTING CEDAR SHAKE SIDING TO BE REMOVED
4. EXISTING SPLIT-FACE CMU TO REMAIN AND BE COVERED BY NEW MATERIALS
AS PROPOSED AND REPAIRED AS NECESSARY
5. STUCCO TO RECEIVE CONTROL JOINTS PER MFR'S RECOMMENDATION AND
PER PATTERNS INDICATED ON ELEVATIONS
6. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING GUTTERS AND
DOWNSPOUTS AND INSTALL NEW GUTTERS AND DOWNSPOUTS WHERE
NOTED AND BE PLUMB AND HORIZONTAL. RE A101
7. ALL EXISTING HEAT TAPE TO BE REPLACED; NEW HEAT TAPED INSTALLED AT
NEW GUTTERS AND DOWNSPOUTS
8. CONTRACTOR TO REMOVE AND REPLACE EXPOSED UTILITIES AS NEEDED TO
COMPLETE THE WORK IN A NEAT AND WORKMANLIKE MANNER
9. CONTRACTOR TO REMOVE AND REPLACE EXTERIOR LIGHT FIXTURES AND ADD
LIGHT AND OUTLET TO EACH UNIT DECK
10. CONTRACTOR TO CLEAN AND REPAINT ALL DECK STRUCTURE TO REMAIN
11. ALL DECKS TO BE RESURFACED WITH REDWOOD DECKING WITH NEW
FLASHING TO BE INSTALLED AT SURROUNDING WALLS AND EDGE. 1 X 6 AT
UNIT DECKS (EXCEPT AT UNIT 501). 2 X 6 AT COMMON WALKWAYS.
12. ALL EXISTING DRYER VENT TERMINATIONS TO BE REPLACED WITH SEIHO
MODEL SFB-P OR SFB AS APPROPRIATE; ALL OTHER VENT TERMINATIONS TO
BE REPLACED WITH SIMILAR SIMILAR TO MATCH 100/200 BUILDING
13. REPAIR AND PATCH EXISTING GYPSUM BOARD SHEATHING WHERE
NECESSARY WTH PLYWOOD
14. REPLACE EXTERIOR CONDUIT AS NECESSARY AND CONCEAL AS CONDITIONS
ALLOW.
15. REPLACE COMMON WALKWAYS, STAIRS AND DECK STRUCTURE PER STRUCT
ENGINEER.
16. REMOVE AND REPLACE EXISTING PAINT ON TIMBER COLUMNS AT COMMON
WALKWAYS
17. ALL EXISTING CONCRETE WALKWAYS TO REMAIN EXCEPT WHERE NOTED
18.
19.
20. ALL MOUNTING ON HARDIE PLANK SIDING TO USE STURDIMOUNT MOUNTING
BLOCKS
21. REFER TO JAMES HARDE WEBSITE FOR REQUIRED INSTALLATION GUIDELINES
(WWW.JAMESHARDIEPROS.COM) REVIEW THE INSTALLATION INSTRUCTIONS
FOR THESE CRITICAL DETAILS(A) CLEARANCE TO SMF (B) CLEARANCE TO
GRADE, CONC., AND ROOF (C) PRIMING OF SIDES, INCLUDING FIELD CUT
EDGES (D) SEALANT AT LOCATIONS AS REQ'D BY MFGR. (E) MFGR.
RECOMENDED DETAILS AT LAP
GENERAL NOTES
CEDAR PLANK - TO BE REMOVED
EXISTING MATERIALS
SPLIT-FACE CMU - TO REMAIN AND
BE COVERED WITH NEW SIDING
ASPHALT
SHINGLES TO
REMAIN
CEMENTIOUS LAP SIDING - 7"
EXPOSURE (MOUNTAIN SAGE - HARDIE
PLANK)¹
PROPOSED MATERIALS
CEMENTIOUS STUCCO
(CROISSANT - SHERWIN WILLIAMS)
¹
STONE¹
¹TO MATCH 100/200 BUILDING
ASPHALT SHINGLES (MATCH
EXISTING)
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
07/05/18
A206
EAST
ELEVATIONBREAKAWAY WEST 500EXTERIOR IMPROVEMENTS1634__963 LIONS RIDGE LOOP, VAIL, CO 8167509/05/17
3/16" = 1'-0"A206
1 EAST ELEVATION -PROPOSED
# DESCRIPTION
1FIBER CEMENT LAP SIDING, 7" EXPOSURE - COLOR: HARDIE FACTORY-APPLIED MOUNTAIN SAGE
JH50-30 BOTH FACES - ON TYVEK BUILDING WRAP
2CEMENTITOUS STUCCO - COLOR: SHERWIN WILLIAMS SW7716 CROISSANT - ON TYVEK BUILDING
WRAP
3BELLY BAND - 2X10 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 VAN BUREN
BROWN
5WINDOW TRIM - 2X6 REAL TRIM BRAND, PAINTED - COLOR: BENJAMIN MOORE HC-71 HASBROUCK
BROWN - OVER VYCOR WINDOW STRIP
8DECK RAILING - POWDER COATED METAL RAILING TO MATCH 100/200 BLDG - COLOR: BLACK
17STONE - TO MATCH EXISTING 100/200 BUILDING
18STUCCO JOINTS TO MATCH 100/200 BUILDING
KEYNOTE LEGEND
PROPOSED CORREGATED MATERIAL
DRB
APPROVED
8/1/2018 12:00:00
AM
UNIT 523
UNIT 513
UNIT 533
A506
6 Sim
A507
5 Sim
UNIT 522
UNIT 532
NOTE: STAIRS
AND RAILINGS
NOT SHOWN FOR
VISUAL CLARITY
EXIST.
MAILBOXES
MOVED TO THIS
LOCATION
NEW SLIDING-
DOOR UTILITY
ENCLOSURE TO
REPLACE EXIST.
NORTH BUILDING
BEYOND
A506
6 Sim
A507
4 Sim
A506
5 Sim
A507
5 Sim
FIRST FLOOR
SOUTH
8203' - 11"
SECOND FLOOR
SOUTH
8212' - 10"
THIRD FLOOR
SOUTH
8221' - 9"
FOURTH FLOOR
SOUTH
8230' - 8"
UNIT 522
UNIT 532
NOTE: STAIRS
AND RAILINGS
NOT SHOWN FOR
VISUAL CLARITY
503
502
501
A506
6 Sim
A506
11 Sim
A506
11 Sim
A506
5 Sim
A507
4 Sim
A507
5 Sim
A506
10 Sim
A507
1 Sim
A506
5 Sim
A506
10 Sim
A505
10 Sim
A506
11 Sim
A506
10 Sim
FIRST FLOOR
SOUTH
8203' - 11"
SECOND FLOOR
SOUTH
8212' - 10"
THIRD FLOOR
SOUTH
8221' - 9"
FOURTH FLOOR
SOUTH
8230' - 8"
A505
10 Sim A507
2 Sim
N
ELEVATION KEY PLAN
2 1
3
S
N
E
5 4 76
CEMENTIOUS LAP SIDING - 7"
EXPOSURE (MOUNTAIN SAGE - HARDIE
PLANK)¹
PROPOSED MATERIALS
CEMENTIOUS STUCCO
(CROISSANT - SHERWIN WILLIAMS)
¹
STONE¹
¹TO MATCH 100/200 BUILDING
ASPHALT SHINGLES
* EXIST. WINDOW/DOOR TO REMAIN
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
A210
SOUTH
BUILDING
ELEVATIONSBREAKAWAY WEST 500EXTERIOR IMPROVEMENTS1634__963 LIONS RIDGE LOOP, VAIL, CO 8167509/05/17
3/16" = 1'-0"A210
3 SOUTH BUILDING -LOOKING EAST -1
3/16" = 1'-0"A210
2 WALK-THROUGH -LOOKING EAST
3/16" = 1'-0"A210
1 WALK-THROUGH -LOOKING WEST
3/16" = 1'-0"A210
6 ELEVATION 1 -LOOKING WEST
3/16" = 1'-0"A210
7 ELEVATION 2 -LOOKING EAST
3/16" = 1'-0"A210
5 DECK 2 -LOOKING EAST
3/16" = 1'-0"A210
4 DECK 2 -LOOKING WEST
DRB
APPROVED
8/1/2018 12:00:00
AM
BASEMENT SOUTH
8195' - 0"
A
NEW STUCCONEW DOORS
NEW ADHERED STONE
VENEER - STOP AT
INSIDE CORNER
EXIST BOLLARD
TO REMAIN
REMOVE AND
REPLACE EXIST.
LIGHT FIXTURE
NEW TRIM
PROVIDE NEW TRIM
AT EXIST OPENING. TYP.
NEW STUCCO
REMOVE EXISTING
WALL-MOUNTD LIGHT
FIXTURE AND
CONDUIT. REPLACE
WITH NEW FIXTURE
AND CONCEAL
CONDUIT
METAL ROOF W/ SNOW FENCING
NEW GATE OR SLIDER DOOR
MOTION SENSOR LIGHT
7' HT GUARD RAIL ABV GRADE
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
07/05/18
A905
GARAGE
ELEVATIONBREAKAWAY WEST 500EXTERIOR IMPROVEMENTS1634__963 LIONS RIDGE LOOP, VAIL, CO 8167509/05/17
1/4" = 1'-0"A905
1 Elevation 3 -a1
1/4" = 1'-0"A905
2 Retaing Wall Elevation -Looking East
1/4" = 1'-0"A905
3 Retaining Wall Elevation -Looking North
1/4" = 1'-0"A905
4 Retaining Wall Plan
DRB
APPROVED
8/1/2018 12:00:00
AM