Loading...
HomeMy WebLinkAboutB18-0280 approved spec sheet.pdf--Sli-Od-~0 MENDOTA "SEABROO Town of Vail f; IE L D DIRECT VENT rJ OPY GAS FIREPLACE INSERT WITH HEARTHGLO COMBUSTION SYSTEM INSTALLATION & OPERATING INSTRUCTIONS CERTIFIED _...........,. We recommend that our gas hearth products be installed and serviced by profes- sionals who are certified in the U.S. by the National Fireplace Institute• (NFI) as NFI Gas Specialists. WARNING: THIS APPLIANCE TO BE USED ONLY AS AN INSERT IN SOLID FUEL BURNING FIREPLACES. NO. DT-0806 ; With ANSI N•tton•I ~ a. W.-rwock H•rs•y ~ ~ .... ; ~ Ill-ii-II ; ~ Certif1ed e ~ G•sAppllanc• /' / / ~-Cf~ ( 0/0/' ... d'? (_? / / /6 ~/1Js/.,/1e {},- A VERTISSEMENT: Cet appareil a etre employe seulment com me un inserer dans lecarburant solide brulant des cheminees. NOTE: THE NAIURAL VENT (B-VENT) SYSTEM CANNOT BE USED 0 VENT THIS~NSERT MODEL! WARNING: This product must be installed by a licensed plumber or gas fitter when installed in the commonwealth of Massachusetts. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier. FOR YOUR SAFETY: DO NOT STORE OR USE GASOLINE OR OTHER POUR VOTRE Securite: Ne pas entreposer ni utiliser d'essence ni d'autre vaperures ou Iiquides FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY inflammables dans le voisinage de cet appareil ou de tout autre apparell. OTHER APPLIANCE. FOR YOUR SAFETY: WHAT TO DO IF YOU SMELL GAS: POUR VOTRE Securite: Que faire si vous sentez une odeur de gaz: I. OPEN WINDOWS. I. Ne pas tenter d'allumer d'appareil 2. DON'T TOUCH ELECTRICAL SWITCHES. 2. Ne touchez a aucun interrupteur. Ne pas vous servir des telephones se trouvant dans le bati- 3. DO NOT USE ANY PHONE IN YOUR BUILDING mcnt ou vous vous trouvez. 4. EXTINGUISH ANY OPEN FLAME 3. Evacuez la piece, le bitiment ou la zone. S. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE. 4. Appelez immediatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du 6. FOLLOW THE GAS SUPPLIERS INSTRUCTIONS. fournisser. 7. IF GAS SUPPLIER IS UNAVAILABLE, CALL YOUR FIRE DEPARTMENT. S. Si vous ne pouvez rejoindre le fournisseur de gas, appelez le service dos incendies. WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, A VERTISSEMENT: Une installation, un reglage, une modification, un entretien ou une mainte- SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY nance incorrects peuvent entrainer des dommages materiels, des lesions corporelles ou la perte de DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL vies humaines. Consuter le manuel des usagers fourn avec ce generateur d'air chaud. INFORMATION, CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY, OR THE GAS SUPPLIER. MISE EN GARDE: Installation, reglage, modification, entretien ou depannage non appropric\s pourront causer des blessures ou des dommages materiels. RHerez-vous au manuel du proprietaire fourni avac cet appariel. Pour assistance ou renseignements complementaires, veulllez consulter un installateur experimente, une agence de depannage/entreitien ou cotre compagnie gaziere. Pour utilisation avec les portes en verre certifiee l'appareil suelement. Ne pas operer avee le verriere enlever, craquelure, brise. z.,,,r._...,,.,,,, "'~"'""' A60•1 ,... 11&1. /111,a l'#lc r1•"''· TABLE OF CONTENTS SPECIFICATIONS ..............................................................•.................................•...............................................•.................. 1 CONGRATULATIONS! ...............................................................................•.........................................................................•. 2 GENERAL INFORMATION ................................................................................................................................................... 3 ELECTRICAL REQUIREMENTS .........................•...•..••.........•.••..•...•..•.•••.•......•.......................•..•..•.•.•.•.......•........•.......•...... 3 SPECIFICATIONS & CLEARANCES .....•........•.................••..••.•.•......•..•............................••.•.•....•..•.•......•................•.....•.... 4 INSTALLATION INSTRUCTIONS .................................•..............••....•................................•...........................................•... 6 FLUE VENTING ..................................•.....•......................•..........•......••........................•........................................................... 7 RAISED HEARTH SPECIFICATIONS ...........................•....................•..........................................•................................... 14 GAS SUPPLY REQUIREMENTS ......................................................•............•..................••.•...............•...........•..............•.... 15 GAS PRESSURE REQUIREMENTS ................................................................................................................................... 16 INSTALLATION CHECK OFF LIST ...............•..............•................................................................................•..............•... 16 LIGHTING CHECK OFF LIST ...............................................•....................•.....•......................•......•...........•..........•..•......... 17 LIGHTING INSTRUCTIONS •.................•........•.......•.......................................................•..................•........................•....... 18 DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS ..............•...•...............................................................•... 20 WALL SWITCH, REMOTE CONTROL OR THERMOSTAT OPERATION ..........................•...•....••.............•.•.....•.•.. 28 BLOWER OPERATION AND WIRING .•......•........•...•................•......••••..•.......•...........••...•.•.•...•.....•...............•.................. 29 BLOWER (S) REMOVAL ..................•..........•.....•.............•......•.......•..............................•................•.................................... 30 CUSTOMER INFORMATION AND TROUBLE-SHOOTING ...............................................................•........................ 31 TROUBLE SHOOTING MENDOTA GAS FIREPLACE INSERT .......••...........•.•.............................•......................•...... 32 GAS FLAME ADJUSTMENT ............................•.................................................................................................................. 32 MAINTENANCE ...................................................•..•.............................................................................................................. 33 REPLACEMENT PARTS LIST ............................................................................................................................................ 34 NATURAL TO LP GAS CONVERSION ...........•.................•........................................................•..............•....................... 35 "LABEL REPRESENTATION" ................•........•..............••...•............................................................................................. 37 MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM ......................................•.............. 38 MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY ................•................•............•.. 42 SPECIFICATIONS MODEL D-40 DEEP TIMBER High Fire -Adj. to -Low Fire BTUH .................................................... NAT. GAS BTUH .................................................... L.P. GAS 40,000 39,000 6,500 6,500 A Natural Gas to LPG conversion kit #HA-34-00178 must be purchased separately to burn LPG. -SEE Pg 35 MAIN ORIFICE ...... REAR BURNER: 32" NAT. GAS [1/16" L.P. GAS] -FRONT BURNER: #48 NAT. [#57 LP] OVERALL EFFICIENCY ....................... EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.) FLUE VENT LINER ............................... CO-LINEAR -4" DIAMETER EXHAUST & 4" DIAMETER INLET or CO-AXIAL -4" DIAMETER EXHAUST & 6 "DIAMETER INLET NET WEIGHT ......................................... 195 lbs. SAFETY .................................................. AGA CERTIFIED PILOT GENERATOR, MILLIVOLT SYSTEM ACTIVATED WITH SWITCH, REMOTE CONTROL OR THERMOSTAT. GAS REQUIREMENTS ......................... SUPPLY PRESSURE: GAS INLET: 3/8" N.P.T. NAT. GAS: 7" W.C. [5 .0" W.C. MIN., 11" W.C. MAX.] L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.] ELECTRICAL REQUIREMENTS ...... 120 Volts AC, 2 Amps LISTINGS INTERTEK TESTING SERVICES TESTED TO: ANSI Z21.11.1-1993 & CANI-2.1 M89 "GAS-FIRED VENTED ROOM HEATERS" & CAN/CGA 2.17-M91 "GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES", ANSI Z21.44-1995 "GAS-DIRECT VENT WALL FURNACES" AND CGA INTERIM REQUIREMENT #41-M91 "DIRECT VENT GAS FIREPLACES" AND UL307B "MOBILE HOME. APPROVED EXCEPT RECREATIONAL VEHICLES" Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American National Standards Institute -ANSI Gas Appliance Safety Standards. For more information see Pg. 37. The Mendota Gas Fireplace Insert has been tested and certified by Intertek Testing Services. 8431 Murphy Drive, Middleton, WI 53562. INSERT INCLUDES HEARTHGLO COMBUSTION SYSTEM, DUAL HOT AIR BLOWERS, 6-PIECE CERAMlC FIBER LOG SET & COALS, NEO- CERAM GLASS, PIEZO IGNITER AND AGA CERTIFIED SAFETY SYSTEM. OPTIONS: BLACK OR BRASS GRILL SETS, BLACK OR GOLD FILIGREE FRONTS, BLACK ARCHED DOOR KITS (ANDOVER), 3 SIZES OF SURROUNDS & 2 TYPES (CO-LINEAR OR COAXIAL) OF VENTING KITS. MENDOTA D-40 GAS DIRECT VENT FIREPLACE INSERT SPECIFICATIONS & CLEARANCES 1<>----34---.... TOP VIEW 8 IN. MIN. CLEARANCE D ...,__ ____ B ____ ___..,.. TRIM D-40 Surround Dimensions -----------------------------_-_--_------~ ~~ ><>-----36----co< FRONT VIEW ----c-J I=-8" MAX. MANTEL I I DEPTH (WIDTH) ~·~ ~llr I -16" MIN. NON-COMBUSTIBLE I HEARTH EXTENSION No Trim With Black or Brass Trim I CO-LINEAR VENT ADAPTER I A Inches mm. 31 788 33 838 36 914 31 1/16 792 33 1116 843 36 1/16 920 MENDOTA D-40 GAS DIRECT VENT FIREPLACE INSERT 4 B Inches 44 48 52 44 1/8 48 1/8 52 1/8 mm. 1118 1220 1321 1122 1224 1326 SPECIFICATIONS & CLEARANCES /; 12" MIN. FROM TOP OF GRILL TO MANTEL 34 1 241 TOP VIEW 8 IN. MIN. CLEARANCE FRONT VIEW __j I--8" MAX. MANTEL I I DEPTH (WIDTH) .. ~ 13 1/4 161/4 13El TRIM i ·rr 19 ========llL,Jll::=:::L....~~ 1 6" MIN. NON-COMBUSTIBLE HEARTH EXTENSION 5 D-40 Surround Dimensions A B Inches mm. Inches No Trim 31 788 44 33 838 48 36 914 52 With Black or 31 1/16 792 44 1/8 Brass Trim 33 1116 843 48 1/8 36 1116 920 52 118 FIGURE 2: D-40 Surround Dimensions CO-AXIAL VENT ADAPTER mm. 1118 1220 1321 1122 1224 1326 FLUE VENTING 10. The D-40 Insert must be vented vertically to the outside and must use the Mendota flexible ducting system. There are two methods for venting Mendota Direct Vent Inserts: 1) Co-Axial and 2) Co-Linear FIGURE3 .---45-01-00069 VERTICAL VENT CAP NOT SUPPLIED WITH KIT ..---45-01-00153 FLASHING/CAP ADAPTER CLAMP CO-AX DIRECT VENT ADAPTER AA-11-00378 COAXIAL VENT KIT CO-AXIAL VENT KIT (Typically for factory built ZC fireplaces.) NOTE: THE INSERT IS DESIGNED, TESTED AND LISTED FOR OPERATION ONLY WITH MENDOTA INSERT VENTING COMPONENTS AS LISTED IN FIGURES 3, 3A, 4 & 4A. FIGURE3A 7 45-01-00069 VERTICAL VENT CAP NOT SUPPLIED WITH KIT 45-01-00153 FLASHING/CAP ADAPTER 5-01-00123 DIRECT VENT ADAPTER BOOT CO-LINEAR DURA-VENT CAP ~AMERI-0~NT ~ ~ 50-06-00073 ~ o ~4" CLAMP t DO DIA. FLEX 0 35' 5' 4" DIA. FLEXLJLJ 4" DIA. FLEX 6" DIA. FLEX t v ~ 50-06-00073 ~~ Q: CLAMP 45-01-00123 0 .V. ADAPTER 45-01-00124 D.V. ADAPTER AA-11-378 CO-AXIAL VENT KIT AA-11-377 CO-LINEAR VENT KIT FIGURE4 NOTE: THE INSERT IS DESIGNED, TESTED & LISTED FOR OPERATION ONLY WITH MENDOTA INSERT VENTING COMPONENTS AS LISTED IN FIGURES 3, 3A, 4 & 4A. 11 . (See FIGURE 4A) The vent kits include a trimable flashing. Measure, trim and shape flashing to fit the existing flue liner. This flashing prevents water and small animals from entering area between the chimney liner and flue liner. Plan for 1" to 1-1/2" (25 mm to 38 mm) overlap on each side. Center the flashing and mark it about 3" (75 mm) larger in each dimension than the existing chimney. Trim the notch with snips and bend edges with hand seaming tool, metal break or pliers. I 18 L~ ~18~ ~FLASHING FIGURE 4A: Chimney Flashing and cap 8