HomeMy WebLinkAboutB18-0280 approved spec sheet.pdf--Sli-Od-~0
MENDOTA "SEABROO
Town of Vail
f; IE L D
DIRECT VENT rJ OPY
GAS FIREPLACE INSERT
WITH
HEARTHGLO COMBUSTION SYSTEM
INSTALLATION & OPERATING INSTRUCTIONS
CERTIFIED _...........,.
We recommend that our gas
hearth products be installed
and serviced by profes-
sionals who are certified in
the U.S. by the National
Fireplace Institute• (NFI) as
NFI Gas Specialists.
WARNING: THIS APPLIANCE TO BE USED ONLY AS AN INSERT IN
SOLID FUEL BURNING FIREPLACES.
NO. DT-0806
; With ANSI N•tton•I ~
a. W.-rwock H•rs•y ~ ~ .... ; ~ Ill-ii-II ; ~ Certif1ed e ~
G•sAppllanc•
/' / / ~-Cf~ ( 0/0/' ... d'? (_?
/ / /6 ~/1Js/.,/1e {},-
A VERTISSEMENT: Cet appareil a etre employe seulment com me un inserer dans
lecarburant solide brulant des cheminees.
NOTE: THE NAIURAL VENT (B-VENT) SYSTEM CANNOT BE USED 0 VENT THIS~NSERT MODEL!
WARNING: This product must be installed by a licensed plumber or gas fitter when installed in the commonwealth of Massachusetts. Improper installation,
adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a
qualified installer, service agency or the gas supplier.
FOR YOUR SAFETY: DO NOT STORE OR USE GASOLINE OR OTHER POUR VOTRE Securite: Ne pas entreposer ni utiliser d'essence ni d'autre vaperures ou Iiquides
FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY inflammables dans le voisinage de cet appareil ou de tout autre apparell.
OTHER APPLIANCE.
FOR YOUR SAFETY: WHAT TO DO IF YOU SMELL GAS: POUR VOTRE Securite: Que faire si vous sentez une odeur de gaz:
I. OPEN WINDOWS. I. Ne pas tenter d'allumer d'appareil
2. DON'T TOUCH ELECTRICAL SWITCHES. 2. Ne touchez a aucun interrupteur. Ne pas vous servir des telephones se trouvant dans le bati-
3. DO NOT USE ANY PHONE IN YOUR BUILDING mcnt ou vous vous trouvez.
4. EXTINGUISH ANY OPEN FLAME 3. Evacuez la piece, le bitiment ou la zone.
S. IMMEDIATELY CALL YOUR GAS SUPPLIER FROM A NEIGHBOR'S PHONE. 4. Appelez immediatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du 6. FOLLOW THE GAS SUPPLIERS INSTRUCTIONS. fournisser.
7. IF GAS SUPPLIER IS UNAVAILABLE, CALL YOUR FIRE DEPARTMENT. S. Si vous ne pouvez rejoindre le fournisseur de gas, appelez le service dos incendies.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, A VERTISSEMENT: Une installation, un reglage, une modification, un entretien ou une mainte-
SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY nance incorrects peuvent entrainer des dommages materiels, des lesions corporelles ou la perte de
DAMAGE. REFER TO THIS MANUAL. FOR ASSISTANCE OR ADDITIONAL vies humaines. Consuter le manuel des usagers fourn avec ce generateur d'air chaud.
INFORMATION, CONSULT A QUALIFIED INSTALLER, SERVICE AGENCY,
OR THE GAS SUPPLIER.
MISE EN GARDE: Installation, reglage, modification, entretien ou depannage non appropric\s pourront causer des blessures ou des dommages materiels. RHerez-vous au manuel du
proprietaire fourni avac cet appariel. Pour assistance ou renseignements complementaires, veulllez consulter un installateur experimente, une agence de depannage/entreitien ou cotre
compagnie gaziere. Pour utilisation avec les portes en verre certifiee l'appareil suelement. Ne pas operer avee le verriere enlever, craquelure, brise.
z.,,,r._...,,.,,,, "'~"'""' A60•1
,... 11&1. /111,a l'#lc r1•"''·
TABLE OF CONTENTS
SPECIFICATIONS ..............................................................•.................................•...............................................•.................. 1
CONGRATULATIONS! ...............................................................................•.........................................................................•. 2
GENERAL INFORMATION ................................................................................................................................................... 3
ELECTRICAL REQUIREMENTS .........................•...•..••.........•.••..•...•..•.•••.•......•.......................•..•..•.•.•.•.......•........•.......•...... 3
SPECIFICATIONS & CLEARANCES .....•........•.................••..••.•.•......•..•............................••.•.•....•..•.•......•................•.....•.... 4
INSTALLATION INSTRUCTIONS .................................•..............••....•................................•...........................................•... 6
FLUE VENTING ..................................•.....•......................•..........•......••........................•........................................................... 7
RAISED HEARTH SPECIFICATIONS ...........................•....................•..........................................•................................... 14
GAS SUPPLY REQUIREMENTS ......................................................•............•..................••.•...............•...........•..............•.... 15
GAS PRESSURE REQUIREMENTS ................................................................................................................................... 16
INSTALLATION CHECK OFF LIST ...............•..............•................................................................................•..............•... 16
LIGHTING CHECK OFF LIST ...............................................•....................•.....•......................•......•...........•..........•..•......... 17
LIGHTING INSTRUCTIONS •.................•........•.......•.......................................................•..................•........................•....... 18
DEEP TIMBER LOG SET INSTALLATION INSTRUCTIONS ..............•...•...............................................................•... 20
WALL SWITCH, REMOTE CONTROL OR THERMOSTAT OPERATION ..........................•...•....••.............•.•.....•.•.. 28
BLOWER OPERATION AND WIRING .•......•........•...•................•......••••..•.......•...........••...•.•.•...•.....•...............•.................. 29
BLOWER (S) REMOVAL ..................•..........•.....•.............•......•.......•..............................•................•.................................... 30
CUSTOMER INFORMATION AND TROUBLE-SHOOTING ...............................................................•........................ 31
TROUBLE SHOOTING MENDOTA GAS FIREPLACE INSERT .......••...........•.•.............................•......................•...... 32
GAS FLAME ADJUSTMENT ............................•.................................................................................................................. 32
MAINTENANCE ...................................................•..•.............................................................................................................. 33
REPLACEMENT PARTS LIST ............................................................................................................................................ 34
NATURAL TO LP GAS CONVERSION ...........•.................•........................................................•..............•....................... 35
"LABEL REPRESENTATION" ................•........•..............••...•............................................................................................. 37
MENDOTA WARRANTY QUALIFICATION & SERVICE REFERENCE FORM ......................................•.............. 38
MENDOTA EXTENDED LIFETIME PROTECTION AND LIMITED WARRANTY ................•................•............•.. 42
SPECIFICATIONS
MODEL D-40 DEEP TIMBER
High Fire -Adj. to -Low Fire
BTUH .................................................... NAT. GAS
BTUH .................................................... L.P. GAS
40,000
39,000
6,500
6,500
A Natural Gas to LPG conversion kit #HA-34-00178 must be purchased separately to burn LPG. -SEE Pg 35
MAIN ORIFICE ...... REAR BURNER: 32" NAT. GAS [1/16" L.P. GAS] -FRONT BURNER: #48 NAT. [#57 LP]
OVERALL EFFICIENCY ....................... EXCEEDS D.O.E. EFFICIENCY REQUIREMENTS (A.F.U.E.)
FLUE VENT LINER ............................... CO-LINEAR -4" DIAMETER EXHAUST & 4" DIAMETER INLET or
CO-AXIAL -4" DIAMETER EXHAUST & 6 "DIAMETER INLET
NET WEIGHT ......................................... 195 lbs.
SAFETY .................................................. AGA CERTIFIED PILOT GENERATOR, MILLIVOLT SYSTEM
ACTIVATED WITH SWITCH, REMOTE CONTROL OR THERMOSTAT.
GAS REQUIREMENTS ......................... SUPPLY PRESSURE: GAS INLET: 3/8" N.P.T.
NAT. GAS: 7" W.C. [5 .0" W.C. MIN., 11" W.C. MAX.]
L.P. GAS: 11" W.C. [11" W.C. MIN., 13" W.C. MAX.]
ELECTRICAL REQUIREMENTS ...... 120 Volts AC, 2 Amps
LISTINGS INTERTEK TESTING SERVICES TESTED TO: ANSI Z21.11.1-1993 & CANI-2.1 M89 "GAS-FIRED VENTED
ROOM HEATERS" & CAN/CGA 2.17-M91 "GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES", ANSI Z21.44-1995
"GAS-DIRECT VENT WALL FURNACES" AND CGA INTERIM REQUIREMENT #41-M91 "DIRECT VENT GAS
FIREPLACES" AND UL307B "MOBILE HOME. APPROVED EXCEPT RECREATIONAL VEHICLES"
Gas appliances must be tested and certified by a nationally recognized testing and certification agency to American National
Standards Institute -ANSI Gas Appliance Safety Standards. For more information see Pg. 37. The Mendota Gas Fireplace
Insert has been tested and certified by Intertek Testing Services. 8431 Murphy Drive, Middleton, WI 53562.
INSERT INCLUDES HEARTHGLO COMBUSTION SYSTEM, DUAL HOT AIR BLOWERS, 6-PIECE CERAMlC FIBER LOG SET & COALS, NEO-
CERAM GLASS, PIEZO IGNITER AND AGA CERTIFIED SAFETY SYSTEM.
OPTIONS: BLACK OR BRASS GRILL SETS, BLACK OR GOLD FILIGREE FRONTS, BLACK ARCHED DOOR KITS (ANDOVER), 3 SIZES OF
SURROUNDS & 2 TYPES (CO-LINEAR OR COAXIAL) OF VENTING KITS.
MENDOTA D-40 GAS DIRECT VENT FIREPLACE INSERT
SPECIFICATIONS & CLEARANCES
1<>----34---....
TOP VIEW
8 IN. MIN. CLEARANCE
D
...,__ ____ B ____ ___..,.. TRIM D-40 Surround Dimensions
-----------------------------_-_--_------~ ~~
><>-----36----co<
FRONT VIEW
----c-J I=-8" MAX. MANTEL I I DEPTH (WIDTH)
~·~
~llr
I -16" MIN. NON-COMBUSTIBLE I HEARTH EXTENSION
No Trim
With Black
or Brass
Trim
I CO-LINEAR VENT ADAPTER I
A
Inches mm.
31 788
33 838
36 914
31 1/16 792
33 1116 843
36 1/16 920
MENDOTA D-40 GAS DIRECT VENT FIREPLACE INSERT
4
B
Inches
44
48
52
44 1/8
48 1/8
52 1/8
mm.
1118
1220
1321
1122
1224
1326
SPECIFICATIONS & CLEARANCES
/;
12" MIN.
FROM TOP
OF GRILL
TO MANTEL
34
1 241
TOP VIEW
8 IN. MIN. CLEARANCE
FRONT VIEW
__j I--8" MAX. MANTEL I I DEPTH (WIDTH)
.. ~
13 1/4
161/4
13El
TRIM
i ·rr 19
========llL,Jll::=:::L....~~
1 6" MIN. NON-COMBUSTIBLE
HEARTH EXTENSION
5
D-40 Surround Dimensions
A B
Inches mm. Inches
No Trim 31 788 44
33 838 48
36 914 52
With Black or 31 1/16 792 44 1/8
Brass Trim
33 1116 843 48 1/8
36 1116 920 52 118
FIGURE 2: D-40 Surround Dimensions
CO-AXIAL VENT ADAPTER
mm.
1118
1220
1321
1122
1224
1326
FLUE VENTING
10. The D-40 Insert must be vented vertically to the outside and must use the Mendota flexible ducting system.
There are two methods for venting Mendota Direct Vent Inserts: 1) Co-Axial and 2) Co-Linear
FIGURE3
.---45-01-00069 VERTICAL VENT CAP
NOT SUPPLIED WITH KIT
..---45-01-00153 FLASHING/CAP ADAPTER
CLAMP
CO-AX DIRECT
VENT ADAPTER
AA-11-00378 COAXIAL
VENT KIT
CO-AXIAL VENT KIT (Typically for factory built ZC fireplaces.)
NOTE: THE INSERT IS DESIGNED, TESTED AND LISTED FOR OPERATION ONLY WITH MENDOTA
INSERT VENTING COMPONENTS AS LISTED IN FIGURES 3, 3A, 4 & 4A.
FIGURE3A
7
45-01-00069 VERTICAL VENT CAP
NOT SUPPLIED WITH KIT
45-01-00153 FLASHING/CAP ADAPTER
5-01-00123 DIRECT VENT
ADAPTER BOOT
CO-LINEAR
DURA-VENT CAP
~AMERI-0~NT ~
~ 50-06-00073 ~
o ~4" CLAMP t DO DIA. FLEX 0 35' 5' 4" DIA. FLEXLJLJ 4" DIA. FLEX
6" DIA. FLEX t v
~ 50-06-00073 ~~
Q: CLAMP
45-01-00123
0 .V. ADAPTER
45-01-00124
D.V. ADAPTER
AA-11-378 CO-AXIAL VENT KIT AA-11-377 CO-LINEAR VENT KIT
FIGURE4
NOTE: THE INSERT IS DESIGNED, TESTED & LISTED FOR OPERATION ONLY WITH MENDOTA
INSERT VENTING COMPONENTS AS LISTED IN FIGURES 3, 3A, 4 & 4A.
11 . (See FIGURE 4A) The vent kits include a trimable flashing. Measure, trim and shape flashing to fit the
existing flue liner. This flashing prevents water and small animals from entering area between the chimney liner
and flue liner. Plan for 1" to 1-1/2" (25 mm to 38 mm) overlap on each side. Center the flashing and mark it
about 3" (75 mm) larger in each dimension than the existing chimney. Trim the notch with snips and bend edges
with hand seaming tool, metal break or pliers.
I
18
L~
~18~
~FLASHING
FIGURE 4A: Chimney Flashing and cap
8