HomeMy WebLinkAboutB18-0284_Approved Plans_1532359304.pdf200A Main AC DISCO AC DISCO DC DISCO DC DISCO J-BOX 12 MODULES IN SERIES WITH SOLAR EDGE P370 12 MODULES IN SERIES WITH SOLAR EDGE P370 12 MODULES IN SERIES WITH SOLAR EDGE P370 12 MODULES IN SERIES WITH SOLAR EDGE P370 MAIN SERVICE PANEL 1 2 3 8 10 M M UTILITY SERVICE 1 4 5 BUILDING GROUNDING Carol & Michael Phillips 2696 Davos Trail Vail, Colorado 81657 16.8 KW SOLAR PV SYSTEM FLUSH MOUNTED TO ROOF DATE: 6/21/2017 REV A SHEET 1 OF 2 722 Iowa Street Golden, CO 80403 303 903-9119 DRAWN BY BKS CHECKED BY WVP CONDUIT AND CONDUCTOR SCHEDULE 1 2 3 TAG DESCRIPTION OR CONDUCTOR TYPE PV WIRE BARE COPPER EGC THWN-2 THWN-2 EGC THWN-2 THWN-2 GROUND 4 THWN-2 THWN-2 GROUND 5,6 THWN-2 THWN-2 GROUND COND. GAUGE 10 10 10 10 8 10 NUMBER OF CONDUCTORS 4 1 8 1 6 1 CONDUIT TYPE N/A N/A EMT EMT CONDUIT SIZE N/A N/A 3/4” 3/4” 4 3 OFFSET 1” 10 1 4 3 EMT 3/4 10 1 EMT INVERTER OUTPUT 4,5,6 32 A X 1.25 = 40A OCPD No Temp Correction. #8 THWN-2 = 55A, 32A ‹ 55A 2 PV SOURCE CIRCUIT (Conduit .5” to 3.5” off roof) = 22C + 41C =66C=.58 x 28A = 16.2 A, 15.132A ‹ 16.2A 9.7A X 1.56 = 15.132A, #10 THWN-2 = 35A X 80% (conduit fill) = 28A,Temp adder 22 C Calculations INVERTER 4 5 DC AC INVERTER 6 DC AC 2 3 40A 40A 7 80A Fuses 9 Supply Side tap 6 EQUIPMENT SCHEDULE 1 3 2 TAG DESCRIPTION PV MODULE PV ARRAY J-BOX PART NUMBER LG 350 W 24 MODULES X 2 NOTES MATED WITH SOLAR EDGE P370 OPTIMIZERS TWO STRINGS OF 12 X 2 WET LOCATION DOUBLE GANG 4 6 5 7 DC DISCO INVERTER AC PANEL AC DISCO N/A SOLAR EDGE X 2 CUTLER HAMLER INTEGRAL TO INVERTER SE7600A-US, UL1741, UL1699B, RAPID SHUTDOWN 100-A 100-A SERVICE-RATED, UTILITY READILY ACCESSIBLE,VISIBLE OPEN, LOCKABLE AND LABELED: PV AC DISCONNECT #1 8 9 SERVICE PANEL AC DISCO GE 240 VAC, 200A MAIN, 200A BUS 100-A SERVICE-RATED, UTILITY READILY ACCESSIBLE,VISIBLE OPEN, LOCKABLE AND LABELED: PV AC DISCONNECT #2 10 M SERVICE PANEL METER GE 240 VAC, 200A MAIN, 200A BUS 240V, 200A 07/23/18 GROUNDING NOTES: 1. Modules grounded together with UNIRAC ETL listed top mount grounding clamps. 2. Each module row connected to EGC with Tyco listed grounding device. 3.Module mounting rails are NOT grounded. 4. Grounded per 2017 NEC PV MODULE RATINGS (STC) MAX POWER-POINT CURRENT (IMP) MAX POWER-POINT VOLTAGE (VMP) OPEN-CIRCUIT VOLTAGE (VOC) SHORT-CIRCUIT CURRENT (ISC) MAX SERIES FUSE (OCPD) MAXIMUM POWER (PMAX) MAX VOLTAGE VOC TEMP COEFF %/Deg C MODULE MAKE MODULE MODEL LG ELECTRONICS 350 W 9.7 36.1 42.7 10.77 20 350 1000V -.28 INVERTER RATINGS MAX DC VOLT RATING MAX POWER @ 40 DEG C NOMINAL AC VOLTAGE MAX AC CURRENT MAX OCPD RATING INVERTER MAKE INVERTER MODEL SOLAR EDGE 7600TL-US 600 VDC 7400 W AC 240 VDC 32.0 AAC 40 A AC NOTES:INVERTER/DC DISCO: WARNING ELECTRIC SHOCK HAZARD IF A GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED DC DISCONNECT WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION Peak Power: 16.8 KW DC Max Power Voltage: 350 V DC Max Power Current: 9.7 A DC Max Open Circuit Voltage: 500 V Short Circuit Current: 10.77 A SERVICE PANEL: WARNING: DUAL POWER SOURCES SECOND SOURCE IS PHOTOVOLTAIC SYSTEM WARNING INVERTER OUTPUT CONNECTION DO NOT RELOCATE THIS OVERCURRENT DEVICE AC DISCO: NET METER HOUSING: PHOTOVOLTAIC SYSTEM CONNECTED Raised relief stamped in all-weather aluminum strip PRODUCTION METER ( PER XCEL ENERGY STANDARD SECTION 4.14.4) 2695 DAVOS TRAIL PV PRODUCTION METER SOLAR DISCONNECT WARNING ELECTRIC SHOCK HAZARD DO NOT TOUCH TERMINALS. TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OPEN POSITION LABELS (PER 2015 IFC 605.11.1 2017 AND NEC) CONDUIT AND ENCLOSURES (PER 2015 IFC 5.11.1): WARNING: PHOTOVOLTAIC POWER SOURCE Carol & Michael Phillips 2696 Davos Trail Vail, Colorado 81657 16.8 KW SOLAR PV SYSTEM FLUSH MOUNTED TO ROOF DATE: 6/21/2017 REV A SHEET 2 OF 2 722 Iowa Street Golden, CO 80403 303 903-9119 DRAWN BY BKS CHECKED BY WVP 07/23/18 20” 16.8 kW PHOTOVOLTAIC (PV) SOLAR SYSTEM 48 350-WATT LG ELECTRONICS SOLAR PANELS FLUSH-MOUNTED on SOUTHEAST-FACING ROOF AREAS Carol & Michael Phillips 2696 Davos Trail Vail, Colorado 81657 Garage Roof House Roof 36” 56” 24” 80” 36” 36” 36” 07/23/18