HomeMy WebLinkAboutDRB18-0359_Approved Plans_1533575472.pdf1
3
7
8
B C N O
5
6
A I J
2
H
4
P
ROOF OVERHANG BOUNDARY
5'-1 3/8" 4'-0" 12'-11 1/8" 6'-1" 5'-10" 10'-0 1/2" 27'-5 1/2" 4'-0"
5'-1 3/8" 66'-4 1/8" 4'-0"4'-0" 2'-4" 10'-2" 10'-2" 2'-4" 1'-0" 3'-0"33'-0"***** SPECIFIED BY CONSULTANTS
8
9
4
10
7
12
2
1
11 1
5
2
64
3
6
3 5
7
8
9
MENS RESTROOM
1
WOMENS
RESTROOM
2
HALLWAY
4
STARTER
8
KITCHEN
5
DINING
7
JANITOR
3
UTILITY
6
STONE COUNTER TO BE SUPPORTED BY METAL BRACKETS
1
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
A1.01
STARTER
SHACK MAIN
LEVELVGC -STARTER SHACKProject Number -xxxx1655 SUNBURST DRVAIL, CO 8165708/01/18
SD
NORTH
1/4" = 1'-0"2 SS - MAIN LEVEL - CAD
BATH ACCESSORIES TO
MATCH CLUB HOUSE BATH
ACCESSORIES
TOILETS ARE WALL
HUNG, TYP.
SANDSTONE CAP, TYP.
ONE GATE, HINGE ON
CORNER OF BUILDING
WASHED GRAVEL INSIDE
OUTDOOR STORAGE AREA
LOCATION OF
DEDICATION PLAQUE STONE COUNTERTOP
BUILT IN CABINETS
DATE NO. DESCRIPTION
7.30.18 1 Change to App
Plans
DRB
APPROVED
8/6/2018 12:00:00
AM
SS - MAIN LEVEL
8232' - 9"
2
A3.01
1
A3.02
2
A3.02
TYP.3
TYP.5
TYP.1
TYP.7
TYP.6
6
12
4.75 12
8252' - 5 1/2"
8244' - 2 1/2"
TYP. 2
1
SS - MAIN LEVEL
8232' - 9"
1
A3.01
TYP.5
TYP.3
TYP.1
TYP.6
TYP.4
6 12
8252' - 5"
8244' - 2 1/2"
TYP.7
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
A2.01
SOUTH &
EAST
ELEVATIONSVGC -STARTER SHACKProject Number -xxxx1655 SUNBURST DRVAIL, CO 8165708/01/18
SD
KEYNOTE LEGEND
KEY
VALUE KEYNOTE TEXT
1 WOOD SIDING
2 STONE
3 ASPHALT SHINGLE ROOF
4 BEIGE STUCCO
5 WOOD TRIM
6 BLACK TRIM
7 ROLL-UP DOOR
1/4" = 1'-0"1 SOUTH ELEVATION
1/4" = 1'-0" 2 EAST ELEVATION
DATE NO. DESCRIPTION
7.30.18 1 Change to App
Plans
DRB
APPROVED
8/6/2018 12:00:00
AM
SS - MAIN LEVEL
8232' - 9"
2
A3.01
1
A3.02
2
A3.02
TYP. 5
6 12
4.75 12
TYP.4
TYP.3
TYP.2
TYP.6
1
SS - MAIN LEVEL
8232' - 9"
1
A3.01
TYP.6
TYP.3
TYP.5
TYP.2
6
12
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
A2.03
NORTH &
WEST
ELEVATIONSVGC -STARTER SHACKProject Number -xxxx1655 SUNBURST DRVAIL, CO 8165708/01/18
SD
KEYNOTE LEGEND
KEY
VALUE KEYNOTE TEXT
1 WOOD SIDING
2 STONE
3 ASPHALT SHINGLE ROOF
4 BEIGE STUCCO
5 WOOD TRIM
6 BLACK TRIM
7 ROLL-UP DOOR
1/4" = 1'-0"2 NORTH ELEVATION
1/4" = 1'-0"1 WEST ELEVATION
DATE NO. DESCRIPTION
7.30.18 1 Change to App
Plans
DRB
APPROVED
8/6/2018 12:00:00
AM
SS - MAIN LEVEL
8232' - 9"
1 4
10'-4"6"
STONE CAP A5.08
2 Sim
2X8 DIMENSIONAL
LUMBER @ 16" O.C. ;
RE STRUCT.
5/8" GYPSUM
WALL BOARD
INTERIOR
STONE VENEER
EXTERIOR
INSULATION, FULL
DEPTH ; R 21MIN
TYVEK MEMBRANE
STRUCTURAL SHEATHING,
RE: STRUCTURE
6 MM. VAPOR
BARRIER
METAL LATH W/
DRAINAGE PLANE
2X4 DIMENSIONAL
LUMBER @ 16" O.C. ;
RE STRUCT.
TYVEK MEMBRANE OVER FLASHING
STRUCTURAL SHEATHING,
RE: STRUCTURE
CANT BLOCKING
HORIZ. WOOD SIDING
2" STONE CAP ; SLOPE TO EXT. ; THICKNESS OF
ADJ ROCK CANNOT EXCEED 1/4" VARIATION
DIM. LUMBER - 5.5"
SHEATHING - 0.625"
SIDING - 0.75"
TOTAL - 6.875"
DIM. LUMBER - 9.25"
SHEATHING - 0.625"
LATH W/ DRAIN PLANE - 0.25"
STONE - 2.75" MIN
TOTAL - 12.875"
CONTINUE TYVEK BEHIND
FLASH AND DOWN 2X8 WALL
INSULATION, R-21
MIN.
2X4 STUDS CONTINUE TO FOUNDATION WALL ; 2X8
SISTERED TO 2X4 STUDS
COPPER FLASHING
SS - MAIN LEVEL
8232' - 9"
I J
A5.08
2 Sim
2X8 DIMENSIONAL LUMBER @ 16" O.C. ;
PARTIAL HEIGHT - FOUNDATION WALL UP TO
3'6" ; SISTER TO 2X4 ; RE STRUCT.
5/8" GYPSUM
WALL BOARD
STONE VENEER
INSULATION, FULL
DEPTH ; R 21MIN
TYVEK MEMBRANE
STRUCTURAL SHEATHING,
RE: STRUCTURE
6 MM. VAPOR
BARRIER
METAL LATH W/
DRAINAGE PLANE
2X4 DIMENSIONAL LUMBER @ 16" O.C. ;
FULL HEIGHT - FOUNDATION WALL TO
SPRING POINT ; RE STRUCT.
TYVEK MEMBRANE
STRUCTURAL SHEATHING,
RE: STRUCTURE
HORIZ. WOOD SIDING
2" STONE CAP ; SLOPE TO EXT. ; THICKNESS OF
ADJ ROCK CANNOT EXCEED 1/4" VARIATION
INSULATION, R-21
MIN.
2X8 BEYOND SISTERED TO 2X4
5/8" GYPSUM
WALL BOARD
6 MM. VAPOR
BARRIER
2X4 STUDS CONTINUE FROM
FOUNDATION WALL TO
SPRING POINT; 2X8
SISTERED TO 2X4 STUDS
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
NOT
FOR
CON
S
T
R
U
C
TI
O
N
A5.08
SIDING TO
STONE
TRANSITIONVGC -STARTER SHACKProject Number -xxxx1655 SUNBURST DRVAIL, CO 8165707/31/18
SD
1/2" = 1'-0"1
WALL SECTION - SIDING TO STONE
TRANSITION
3" = 1'-0"2 WOOD SIDING TO STONE TRANSITION
1/2" = 1'-0"3
WALL SECTION - SIDING TO STONE
TRANSITION - ENTRY
3" = 1'-0"4
WOOD SIDING TO STONE TRANSITION
PLAN VIEW
DRB
APPROVED
8/6/2018 12:00:00
AM