Loading...
HomeMy WebLinkAboutB18-0283_Approved Documents_1534542400.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspections: inspections@vailgov.com Construction B18-0283 Issued: 08/17/2018 TOWN OF VAIL Property Information Address: 4425 GLEN FALLS LN (210112313002) ( 210112313002 ) Unit #: Parcel Number: 210112313002 Legal Description: Subdivision: FOREST GLEN Lot: 2 BK-0587 PG-0376 MAP 08-19-92 BK-0587 PG-0377 DEC 08-19-92 BK-0643 PG-0741 QCD 06-16-94 R669632 DEC 09-17-98 R923883 MAP 07-26-05 R200800537 QCD 11-20-07 Contacts Contact Type: Applicant Full Name: Jeff Cohen Address: 210 Edwards Village Boulevard A201 Edwards, CO 81632 Phone: 970-926-3443 Contact Type: Property Owner Full Name: SSCS LLC Address: Phone: None Contact Type: Architect Full Name: Gregory Sparhawk Address: 301 Boulder Street 333 Minturn, CO 81645 Phone: 9704704945 Contact Type: Site Superintendent Full Name: Jeffrey Cohen Address: P.O. Box 1889 210 Edwards Village Blvd. A201 Edwards, CO 81632 Phone: 9709263443 Contractor Contractor Type: General Company: Cohen Construction, Inc State License #: Phone: 970-926-3443 Project Information Project Name: SSCS LLC 2018 Project Description:Addition to northeast corner of home on two stories. addition of dormer at north roof. removal of chimney and re-roof of entire home. additional interior renovation work and some window replacement. Fees Paid Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$3,233.75 Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$2,101.94 Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$9,800.00 Account #: 109-0000.31133.00 - Housing Fee-in-Lieu Fee Amount:$7,858.84 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$600.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$150.00 Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$1,050.00 Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$262.50 Account #: 111-0000.31127.00 - Recreation Fee Fee Amount:$88.20 Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00 Total Paid:$25,160.23 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. PERMIT FEE RECEIPT Case # B18-0283 Date Printed: 08/17/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B18-0283 Status: Approved Permit Number: Date Started: 07/06/2018 Permit Type: Construction Subcases Single Family Lot Number: 2 Property: 4425 GLEN FALLS LN (210112313002) (210112313002) Contacts Contact Type: Applicant Company Name: Cohen Construction, Inc Full Name: Jeff Cohen Address: 210 Edwards Village Boulevard A201 Edwards, CO 81632 Email: jcohen@cohenconstructioninc.com Contact Type: Property Owner Full Name: SSCS LLC Address: Contact Type: Architect Company Name: Gps Designs, LLC Full Name: Gregory Sparhawk Address: 301 Boulder Street 333 Minturn, CO 81645 Email: gregs@gpsdesigns.com Contact Type: Site Superintendent Company Name: Cohen Construction Inc. Full Name: Jeffrey Cohen Address: P.O. Box 1889 210 Edwards Village Blvd. A201 Edwards, CO 81632 Email: jcohen@cohenconstructioninc.com Permit Fees Fee Information Account Amount Permit Fee 001-0000.31111.00 $4,883.75 Construction Tax 110-0000.31060.00 $9,800.00 Housing Fee-in-Lieu 109-0000.31133.00 $7,858.84 Recreation Fee 111-0000.31127.00 $88.20 Will Call Fee 001-0000.31128.00 $15.00 Payment Information Date Paid Payment Type Amount Permit Fee 08/17/2018 Check $4,883.75 Paid By: Cohen Construction - Notes: ck#5465 Recreation Fee 08/17/2018 Check $88.20 Paid By: Cohen Construction - Notes: ck#5465 Construction Tax 08/17/2018 Check $9,800.00 Paid By: Cohen Construction - Notes: ck#5465 Housing Fee-in-Lieu 08/17/2018 Check $7,858.84 1 / 2 PERMIT FEE RECEIPT Case # B18-0283 Date Printed: 08/17/2018 Paid By: Cohen Construction - Notes: ck#5465 Will Call Fee 08/17/2018 Check $15.00 Paid By: Cohen Construction - Notes: ck#5465 FEE TOTAL $22,645.79 AMOUNT PAID $22,645.79 BALANCE DUE $0.00 08/17/2018 - 3:34:33 PM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657 2 / 2 Enviro Care Consulting Services, LLC 7100 Broadway Suite 2-N – Denver, Colorado 80221 August 2, 2018 Cohen Construction Inc. Jeff Cohen PO Box 1889 210 Edwards Village Blvd Unit A201 Edwards, Colorado 81632 RE: Limited Asbestos Building Inspection 4425 Glen Falls Lane– Vail, Colorado 81657 Enviro Care Project Number: 080118-1 Dear Mr. Cohen: Enviro Care Consulting Services LLC (Enviro Care) is pleased to submit this report summarizing our limited Asbestos Containing Materials (ACM) inspection to facilitate renovation or restoration of the structure. This report details the fieldwork completed and analytical results of samples collected. It is our understanding that you are planning renovation activities at the above referenced address. Per the United States Environmental Protection Agency (EPA) procedures published in Code of Federal Regulations (CFR) Title 40 Part 763, Subpart E – Asbestos-containing Materials in Schools and Colorado Regulation 8 (Regulation 8), suspect Asbestos Containing Building Materials (ACBM) must be properly sampled and analyzed prior to any renovation or demolition activities. The purpose of this sampling was to evaluate for the presence of any ACM in the areas identified. The inspection was conducted in accordance with Regulation 8. These inspection protocols specify requirements for the inspector (Section 763.85), laboratory (Section 763.87), and number of samples collected during an inspection (Section 763.86). 1.0 FIELD ACTIVITIES The inspection was conducted by a Colorado State Certified Asbestos Building Inspector on August 1, 2018. This inspection involved identification and sampling of suspect ACM at the above referenced property. Bulk samples of suspect ACM were collected by the Inspector in general conformance with Asbestos Hazardous Emergency Response Act (AHERA) protocols as outlined in Colorado Department of Public Health and Environment (CDPHE) Regulation 8. Random samples of suspect materials were collected in each homogeneous area (see Table 1 – Homogeneous Materials Table). Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker. 2.0 LABORATORY ANALYSIS Eleven (11) samples were submitted under chain of custody procedures to Reservoirs Environmental (RE) for analysis by polarized light microscopy (PLM) with dispersion staining techniques per EPA methodology (40 CFR 763, Subpart F). Visual estimations were used in obtaining the percentage of asbestos in bulk samples. RE is accredited under the National 2 Voluntary Laboratory Accreditation Program (NVLAP). A copy of the original laboratory report is attached to this summary report. 3.0 FINDINGS Suspect ACM includes nearly all building materials except bare concrete, glass, wood, masonry, metal or rubber. ACM contains asbestos greater than 1 percent, (> 1% asbestos) as confirmed by an accredited laboratory. ACM is categorized as Friable or Non-friable asbestos. Friable asbestos can be crumbled, pulverized, or reduced to a powder by hand pressure when dry. Non- friable asbestos is any material that cannot be crumbled, pulverized or reduced to a powder by hand pressure when dry. Our Inspector observed the following suspect ACM during this inspection: Friable:  Orange Peel Textured Surfacing Material on Drywall;  Smooth Knock Down Textured Surfacing Material on Drywall;  Smooth Textured Surfacing Material on Drywall; and  Tape and Joint Compound. Non-friable:  No non-friable materials were tested 3.1 Identified Asbestos Containing Materials Based on the completed PLM results, asbestos was not identified in the samples collected. Table 2, enclosed, contains a summary of samples and results. 4.0 CONCLUSION & RECOMMENDATION Only listed materials were tested or quantified as part of this inspection. If materials are encountered that have not been discussed in this report, stop all construction activities and contact a Colorado Certified Asbestos Building Inspector to test those materials prior to continuing with building demolition. 5.0 LIMITATIONS This asbestos inspection was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and/or recommendations expressed in this report are based on conditions observed during our asbestos building inspection of the areas identified as the renovation area. The information contained in this report is relevant to the date on which this survey was performed, and should not be relied upon to represent conditions at a later date. This asbestos inspection report is not considered a comprehensive asbestos inspection 3 report and it must be understood that the existence of unique or concealed ACM may be possible. This report has been prepared on behalf of and exclusively for use by the client for specific application to the project as discussed. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Enviro Care does not warrant the work of regulatory agencies or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made. This report is not to be used as a bidding document. Should you have any questions or require additional information, please feel free to contact our office at 720-390-5768. Sincerely, Andrew Fiegel Enviro Care Consulting Services LLC Colorado State Certified Asbestos Building Inspector # 24138 Enclosures: Table 1 - Homogenous Materials Table 2 - Summary of Asbestos Samples and Results Laboratory Analytical Report TABLE 1 HOMOGENEOUS MATERIALS TABLE Asbestos Containing Materials are Listed in Red. Table 1 HOMOGENEOUS MATERIALS TABLE 4425 Glen Falls Lane Vail, Colorado 81657 HA Description Estimated Quantity Locations Friable Non-Friable Category Hazard Ranking & Disturbance Potential 1 Orange Peel Textured Surfacing Material on Drywall 600 ft 2 Living Room, Lounge Room, Master Bath F NA/High 2 Smooth Knock Down Textured Surfacing Material on Drywall 500 ft 2 2 nd Floor Northeast Bathroom F NA/High 3 Smooth Textured Surfacing Material on Drywall 500 ft 2 1 st Floor Northeast Room F NA/High 4 Tape and Joint Compound 175 ft2 Throughout All Areas F NA/High Friable: material that be crumbled, pulverized, or reduced to powder with hand pressure when dry Non-Friable: material that cannot be crumbled, pulverized, or reduced to powder with hand pressure when dry Thermal Systems Insulation (TSI): used to control heat transfer and or condensation on HVAC, hot and cold water or other mechanical systems etc. Surfacing Material: material that is sprayed or troweled onto surfaces such as fire proofing on structural members, plaster for acoustical, decorative, etc. Miscellaneous Material: all other materials including taping mud, floor tile mastic, stucco, leveling compound, and hard plasters. Category I non-friable ACM: resilient floor coverings, asphalt roofing products, packings, gaskets, or galbestos containing greater than 1% asbestos Category II non-friable ACM: any material that is not Cat1 that contains greater than 1% asbestos Asbestos Containing Materials are Listed in Red. Hazard Ranking: 1= damaged or significantly damaged Thermal Systems Insulation (TSI) ACM; 2=damaged friable surfacing ACM; 3=significantly damaged friable surfacing ACM; 4=damaged or significantly damaged friable miscellaneous ACM; 5=ACBM with potential for damage; 6=ACBM with potential for significant damage; 7=any remaining friable ACBM or suspected ACBM. Disturbance Potential: Low = the material may be accessible but is not likely to be damaged under most circumstances. Moderate = the material is accessible and is likely to suffer limited damage over time. High = the material is friable and/or already damaged, is accessible, and there is specific reason to believe the material will receive a large amount of damage in the foreseeable future. Condition: Good = the material had no visible damage, or extremely minor damage or surface marring (i.e., a room of floor tile has only four or five with small corners broken from the tile. Damaged = the material had visible damage evenly distributed over less than 10% of its surface, or localized over less than 25% of its surface. Significantly damaged = the material had visible damage that is evenly distributed over 10% or more of its surface, or localized over 25% or more or its surface. TABLE 2 SUMMARY OF COLLECTED SAMPLES AND ANALYTICAL RESULT ND = No Asbestos Detected Sample Results are Expressed in Percentage and Type of Asbestos Mineral Present. Sample Sets That are Greater than 1% Asbestos are Listed in Red. Sample Sets Listed in Blue are OSHA Regulated Materials. TABLE 2 SUMMARY OF COLLECTED SAMPLES AND ANALYTICAL RESULT 4425 Glen Falls Lane Vail, Colorado 81657 SAMPLE NUMBER MATERIAL DESCRIPTION SAMPLE LOCATION ASBESTOS SAMPLE RESULTS HOMOGENOUS MATERIAL AND CONDITION SM 1-1 Orange Peel Textured Surfacing Material on Drywall 1st Floor Living Room 6” West of Chimney above Mantle ND 1/Good SM 1-2 Orange Peel Textured Surfacing Material on Drywall 1st Floor Northwest Lounge Room West Edge of Fireplace 6” high ND 1/Good SM 1-3 Orange Peel Textured Surfacing Material on Drywall 2nd Floor Master Bath South Wall Behind Clock ND 1/Good SM 2-1 Smooth Knock Down Textured Surfacing Material on Drywall 2nd Floor Northeast Bathroom Behind Java Photo ND 2/Good SM 2-2 Smooth Knock Down Textured Surfacing Material on Drywall 2nd Floor Northeast Bathroom North Wall East of Window 4’ High ND 2/Good SM 2-3 Smooth Knock Down Textured Surfacing Material on Drywall 2nd Floor Northeast Bathroom South Wall above Commode behind Blue Moon Painting ND 2/Good SM 3-1 Smooth Textured Surfacing Material on Drywall 1st Floor Northeast Room North Wall West of Fireplace 1” Above Floor ND 3/Good SM 3-2 Smooth Textured Surfacing Material on Drywall 1st Floor Northeast Room North Wall 6’ West of Double Doors 1.5’ High ND 3/Good SM 3-3 Smooth Textured Surfacing Material on Drywall 1st Floor Northeast Room North Wall ND 3/Good TJC 1-1 Tape and Joint Compound 2 nd Floor Master Bathroom Northeast Corner Behind Commode 4” High ND 4 Good ND = No Asbestos Detected Sample Results are Expressed in Percentage and Type of Asbestos Mineral Present. Sample Sets That are Greater than 1% Asbestos are Listed in Red. Sample Sets Listed in Blue are OSHA Regulated Materials. TABLE 2 SUMMARY OF COLLECTED SAMPLES AND ANALYTICAL RESULTS 4425 Glen Falls Lane Vail, Colorado 81657 SAMPLE NUMBER MATERIAL DESCRIPTION SAMPLE LOCATION ASBESTOS SAMPLE RESULTS HOMOGENOUS MATERIAL AND CONDITION TJC 1-2 Tape and Joint Compound 2nd Floor Northeast Bathroom Northwest Corner 6” High ND 4/Good LABORATORY ANALYTICAL REPORTS Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective April 2, 2018 Q:\QAQC\Lab\Reservoirs Environmental QA Manual.doc Subcontract Number: NA Laboratory Report: RES 415034-1 Project # / P.O. # 080118-1 Project Description: Vail RES 415034-1 Sincerely, August 2, 2018 Dear Customer, Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0 for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs respectively. Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The analysis has been completed in general accordance with the appropriate methodology as stated in the attached analysis table. The results have been submitted to your office. Enviro Care Consulting 7100 Broadway Suite 2-N Denver CO 80221 Andrew Fiegel is the job number assigned to this study. This report is considered highly confidential and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with personnel other than those of the client. The results described in this report only apply to the samples analyzed. This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any questions about this report, please feel free to call 303-964-1986. Jeanne Spencer President P: 303-964-1986 F: 303-477-4275 5801 Logan Street, Suite 100 Denver, CO 80216 Page 1 of 1 1-866-RESI-ENV www.reilab.com RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 415034-1 Enviro Care Consulting 080118-1 Vail August 01, 2018 Rush August 01, 2018 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective April 2, 2018 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method: EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 1000 SM 1-1 EM 2138695 Off white texture w/ tan paint A 12 ND 4060 Tan/off white drywall B 88 ND 1000 SM 1-2 EM 2138696 White texture w/ tan paint A 8 ND 5545 Gray/tan drywall w/ white paint B 92 ND 1000 SM 1-3 EM 2138697 White texture w/ tan/beige paint A 20 ND 6040 Off white/tan drywall B 80 ND 1000 SM 2-1 EM 2138698 White texture w/ off white paint A 20 ND 6535 Gray/tan drywall B 80 ND 1000 SM 2-2 EM 2138699 White texture w/ off white paint A 35 ND 5545 Gray/tan drywall B 65 ND 1000 SM 2-3 EM 2138700 White texture w/ off white paint A 40 ND 6535 Gray/tan drywall B 60 ND 1000 SM 3-1 EM 2138701 White texture w/ brown/multi-colored paint A 100 ND 1000 SM 3-2 EM 2138702 White texture w/ brown/multi-colored paint A 100 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 1 of 2 RES Job Number: Client: Client Project Number / P.O.: Client Project Description: Date Samples Received: Turnaround: Date Samples Analyzed: RES 415034-1 Enviro Care Consulting 080118-1 Vail August 01, 2018 Rush August 01, 2018 TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME Reservoirs Environmental, Inc. Reservoirs Environmental QA Manual Effective April 2, 2018 Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc RESERVOIRS ENVIRONMENTAL INC. NVLAP Lab Code 101896-0 Client Sample Number Lab ID Number L A Y E R Mineral Method: EPA 600/R-93/116 - Short Report, Bulk Physical Description Sub Part (%) Visual Estimate (%) ND=None Detected TR=Trace, <1% Visual Estimate Trem/Act=Tremolite/Actinolite Non Asbestos Fibrous Components (%) Non- Fibrous Components (%) Asbestos Content 1000 SM 3-3 EM 2138703 White texture w/ brown/multi-colored paintA 40 ND 3070 Tan/gray drywallB 60 ND 1000 TJC 1-1 EM 2138704 White texture w/ tan paintA 12 ND 1000 White tapeB 20 ND 8020 Off white/tan drywallC 68 ND 2080 TJC 1-2 EM 2138705 Yellow fibrous woven materialA 5 ND 1000 White texture w/ off white paintB 15 ND 8812 Gray/tan drywallC 80 ND TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%. Analyst / Data QAAnalyst Analyst Analyst Analyst P: 303-964-1986 F: 303-477-4275 1-866-RESI-ENV www.reilab.com 5801 Logan Street, Suite 100, Denver, CO 80216 Page 2 of 2