HomeMy WebLinkAboutB18-0283_Approved Plans_1534542461.pdfA0.1 GRFA CALCS EXISTING PLANS 1 8" = 1'-0"2 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92PROPOSED PLANS 18" = 1'-0"1 1,928.4 sf 1,555.6 sf 537.0 sf TOTAL 3,484.0 sf 2,009.7 sf 1,719.5 sf 563.7 sf TOTAL 3,729.2 sf 08/17/18 A1.1 MAIN LEVEL PLANMAIN LEVEL 1 4" =1'-0"1 C 2018 GPS Designs LLCISSUE3 August 2018RELEASE Permit - Rev AShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92GARAGE 101 FAMILY RM 111 KITCHEN 109 DINING 108 HEARTH 107 LIVING 106 ENTRY 105 PANTRY 110 POWDER 104 3 4 BATH 103 MUD RM 102 CLO EXTEND DECK 4'-6" OUT. OPEN HOLE INSPECTION AT EXCAVATION FOR NEW FOOTER/FDN REMOVE SMALL CORNER GAS FIREPLACE DASHED WALLS REPRESENT EXISTING WALLS TO BE REMOVED, COORDINATE WITH STRUCTURAL POSTS TO REMAIN UPON REMOVAL OF DRYWALL. NEW STAIR AND MUD ROOM CONFIGURATION, UPPER TWO RUNS OF STAIRS TO REMAIN. NEW LOWER FLIGHT TO TIE INTO EXISTING LANDING. NEW TREADS TO BE 101 2" DEEP (RISER TO RISER) 1(: 5,6(56 72 0$7&+ (;,67,1*  “58" ‘ +$1'5$,/  $%29( 126,1* ,) 2:1(5 ELECTS TO CHANGE BALUSTERSAND NEWELS, SPACING SHALL NOT EXCEED 37 8" CLEAR. NEW DIRECT VENT GAS FIREPLACE. 42" MAJESTIC MARQUIS II WOOD BURNING FIREPLACE TO BE REMOVED DECK A3.1 1 A3.1 2 A3.0 1 A3.0 2 A3.3 2 A3.3 1 A3.2 2 A3.2 1 A3.1 1 A3.1 2 A3.0 1 A3.0 2 A3.3 2 A3.3 1 A3.2 2 A3.2 1 MECHANICAL 112 EXISTING MECHANICAL SYSTEMS TO REMAIN, EXTEND CURRENT ZONES TO INCLUDE ADDED SPACES REMOVE OVERFRAMED STEP AND TIE BACK TO OPENING AT ENTRY NEW FLUSH BEAM TO BE PLACED AT BEARING WALL BEING REMOVED NEW WINDOWS TO MATCH WIDTH OF EXISTING, RAISE SILL TO PROVIDE ADDITIONAL PRIVACY FOR EXISTING HOT TUB. DASHED WALS ARE EXISTING TO BE REMOVED TMPRD NEW DIRECT VENT GAS FIREPLACE. 36" MAJESTIC MARQUIS II NEW WALLS AND CEILING AT GARAGE TO LIVING SPACE MUST BE PROVIDED WITH 5 8" TYPE X DRYWALL UP NON-BEARING INTERIOR PARTITION WITH POCKETING PRIVACY DOORS TIED TO CEILING AT EITHER END RE: DTLS TMPRD TMPRD TMPRD A 08/17/18 A1.2 UPPER LEVEL PLANMAIN LEVEL 1 4" =1'-0"1 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92A3.1 1 A3.1 2 A3.0 1 A3.0 2 A3.3 2 A3.3 1 A3.2 2 A3.2 1 A3.1 1 A3.1 2 A3.0 1 A3.0 2 A3.3 2 A3.3 1 A3.2 2 A3.2 1 LANDING 201 MASTER BED 202 M BATH 203 BED 2 204 BATH 205 LAUNDRY 206 BATH 207 BATH 210 BED 4 209 BED 3 208 CLO CLO CLO CLO AREA OF ADDITION MASTER SUITE EXPANDS AND RECEIVES NEW ROOF AREA OVER SNOW DAMMING AREA AREA OF DORMER TO MATCH EXISTING CONDITION TOWARD FRONT OF HOUSE RECONFIGURE ARCH TOP WINDOWS AREA OF DORMER TO MATCH EXISTING CONDITION TOWARD FRONT OF HOUSE TMPRD TMPRD TMPRD TMPRD OPERABLE VELUX SKYLIGHT, CURB MOUNTED OPERABLE VELUX SKYLIGHT, CURB MOUNTED TUB LOCATION TO REMAIN, SINKS AND VANITY TO SWITCH WALLS DN EXIST UP 2R UP 2R EXIST. 08/17/18 A1.3 ROOF PLANMAIN LEVEL 1 4" =1'-0"1 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92A3.1 1 A3.1 2 A3.0 1 A3.0 2 A3.3 2 A3.3 1 A3.2 2 A3.2 1 A3.1 1 A3.1 2 A3.0 1 A3.0 2 A3.3 2 A3.3 1 A3.2 2 A3.2 1 08/17/18 ISSUE6 July 2018RELEASEPermitShapiro Addition / RenovationStan and Carol Shapiro4425 Glenn Falls LaneVail CO 81657PROJECT4425 Glenn Falls LanePROJECT NO.17_SR-0002gps designs, llc301 Boulder St, #333Minturn CO 81645EXISTING ELEVATIONS AREA THAT OWNERS SEE WATER DAMAGE, TWO SLOPING ROOFS CREATE DAMMING ISSUE. ALL EXISTING CEDAR SHAKE ROOFING TO BE REMOVED NAD REOLACED WITH SYNTHETIC SHAKE, CLASS-A EXISTING CHIMNEY TO BE REMOVED A2.1 West Elevation 3/16" = 1'-0"1 North Elevation - river side 3/16" = 1'-0"2 East Elevation 3/16" =1'-0"4 Front Elevation - street side 3/16" = 1'-0"3 08/17/18 ISSUE3 August 2018RELEASEPermit - Rev AShapiro Addition / RenovationStan and Carol Shapiro4425 Glenn Falls LaneVail CO 81657PROJECT4425 Glenn Falls LanePROJECT NO.17_SR-0002gps designs, llc301 Boulder St, #333Minturn CO 81645PROPOSED ELEVATIONS G BRIDGE VALLEY WITH SHALLOW ROOF "DORMER". THIS ROOF IS ALMOST IMPOSSIBLE TO ACTUALLY SEE WITH HOME SITTING SO HIGH ON SOUTH BANK OF CREEK EGRESS AREA OF ADDITION AREA OF ADDITION RETAIN EXISTING FENESTRATION PATTERN, REMOVE REAR DECK AND ADD SHALLOW GUARD AT DOORS. REDWOOD TO MATCH EXISTING DECK NEW WINDOWS TO MATCH EXISTING IN MATERIAL, STYLE AND COLOR MAINTAIN EXISTING RIDGE HEIGHT, RIDGE FALLS UNDER MAXIMUM HEIGHT OF EXISTING ROOF. NEW ROOF THROUGHOUT. DAVINCI ROOF, SYNTHETIC SHAKE BELLAFORTE "TAHOE" RAISE SILL OF FRONT WINDOW TO ALLOW FOR STAIR CLEARANCE BEHIND SMALL BUMPOUTS AT WEST WALL FOR NEW GAS FIREPLACES INSIDE, STUCCO TO MATCH EXISTING. CUSTOM, DECORATIVE FLUE CAPS NEW WINDOWS, SYMMETRICALLY FLANKING CHIMNEYS. WINDOWS STYLE AND PAINT TO MATCH EXISTING NEW STUCCO SIDING TO MATCH EXISTING, TEXTURE AND COLOR. NEW FASCIA AND SOFFIT TO MATCH EXISTING, TEXTURE AND COLOR. EXISTING CHIMNEY TO BE REMOVED G X EGRESS XX X C XX X X X XX X XFDD E 1 H H TMPRD EGRESS TMPRD TMPRD TMPRD J TMPRD K X A A B B TMPRD A A2.2 West Elevation 3/16" = 1'-0"1 North Elevation - river side 3/16" = 1'-0"2 East Elevation 3/16" =1'-0"4 Front Elevation - street side 3/16" = 1'-0"327'-4 1/4"REMAINS UNCHANGED27'-1/4"7'-0"3'-0"6'-1"7'-0"08/17/18 A3.0 BUILDING SECTIONSMAIN LEVEL 3 16" = 1'-0"1 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92MAIN LEVEL 3 16" = 1'-0"2 1 A3.2 2 A3.2 1 A3.3 2 A3.3 1 A3.2 2 A3.2 1 A3.3 2 A3.3 LANDING 201 BATH 207 BATH 210 MASTER BED 202 LAUNDRY 206 CLO CLO W/C BATH 205 GARAGE 101 LIVING 106 MUD RM 102 FAMILY RM 111 LIVING 106 PANTRY 110 AREAS OF HATCHING ARE EXISTING CONSTRUCTION AREAS OF HATCHING ARE EXISTING CONSTRUCTION EXISTING CHIMNEY TO BE REMOVED LINE OF ROOF BEYOND NEW DIRECT VENT GAS FIREPLACE, 42" MAJESTIC MARQUIS II EXISTING CRAWL SPACE UNCHANGED EXISTING CRAWL SPACE UNCHANGED 08/17/18 7'-118"A3.1 BUILDING SECTIONSMAIN LEVEL 3 16" = 1'-0"1 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92MAIN LEVEL 3 16" = 1'-0"2 1 A3.2 2 A3.2 1 A3.3 2 A3.3 1 A3.2 2 A3.2 1 A3.3 2 A3.3 MASTER BED 202 M BATH 203 BED 2 204 BATH 205 MASTER BED 202 M BATH 203 BED 2 204 BATH 205 FAMILY RM 111 KITCHEN 109 DINING 108 HEARTH 107 FAMILY RM 111 KITCHEN 109 DINING 108 HEARTH 107 AREAS OF HATCHING ARE EXISTING CONSTRUCTION AREAS OF HATCHING ARE EXISTING CONSTRUCTION NEW DORMER AT BATHROOM NEW SHED ROOF AT MASTER BATHROOM NEW BEAM TO CARRY RAFTERS PROFILE OF ADDITION TO MATCH EXISTING MASSING NEW CRICKET AT WALL OF NEW MASTER BATH EXISTING CRAWL SPACE UNCHANGED EXISTING CRAWL SPACE UNCHANGED NEW CRAWL SPACE CONNECT THROUGH TO EXISTING CRAWL 08/17/18 1114"6'-738"A3.2 BUILDING SECTIONSMAIN LEVEL 3 16" = 1'-0"1 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92MAIN LEVEL 3 16" = 1'-0"2 2 A3.0 1 A3.0 2 A3.1 1 A3.1 2 A3.0 1 A3.0 2 A3.1 1 A3.1 MASTER BED 202 LANDING 201 M BATH 203 DECK DECK HEARTH 107 LIVING 106 DINING 108 PANTRY 110 POWDER 104 ENTRY 105 AREAS OF HATCHING ARE EXISTING CONSTRUCTION AREAS OF HATCHING ARE EXISTING CONSTRUCTION EXISTING FIREPLACE ANDBUILT-IN TO BE REMOVED, PROVIDE LOW WALL AND COLUMNS PER PLAN EXISTING ROOF BEYOND 08/17/18 37'-0"7'-814"4'-0"MINA3.3 BUILDING SECTIONSMAIN LEVEL 3 16" = 1'-0"1 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92MAIN LEVEL 3 16" = 1'-0"2 A3.1 1 A3.1 2 A3.0 1 A3.0 2 A3.1 1 A3.1 2 A3.0 1 A3.0 2 M BATH 203 CLO LANDING 201 BED 2 204 BATH 210 BED 4 209CLO GARAGE 101 FAMILY RM 111DECK KITCHEN 109 MUD RM 102 MECH STAIR AREAS OF HATCHING ARE EXISTING CONSTRUCTION AREAS OF NEW SHED ROOF DORMER AND MASTER SUITE REMODEL AREAS OF HATCHING ARE EXISTING CONSTRUCTION NEW STEEL BENT AT ADDITION, RE: STRUCT 08/17/18 ISSUE6 July 2018RELEASEPermitShapiro Addition / RenovationStan and Carol Shapiro4425 Glenn Falls LaneVail CO 81657PROJECT4425 Glenn Falls LanePROJECT NO.17_SR-0002gps designs, llc301 Boulder St, #333Minturn CO 81645PerspectivesA4.1 View from front actually a large evergreen will block this view, but shows visual impact of addition2 View from northeast taken approx. 12' above creek 1 Bird's eye from Northwest impossible to see this angle, but provides clear view of water issue3 08/17/18 A5.1 BUILDING DETAILS Dormer Wall to Roof 1 12" = 1'-0"3 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92Skylight Head Detail 1 12" = 1'-0"2 Stair Detail 1 12" = 1'-0" 1 Partition @ Family Room 1 12" = 1'-0" 5 Dormer Fascia 1 12" = 1'-0" 4 08/17/18 A5.2 WATER PROTECTION DETAILS C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-9208/17/18 A5.3 AIR INFILTRATION DETAILS C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-9208/17/18 A B C D E 2'-6" F G H I J EGRESS2'-0"2'-0" 4'-6" 3'-2" VERIFY EXISTING OPENING AND GLAZING SIZE3'-0"3'-0" 4'-0"3'-0" 1'-0"6'-0"4'-0" 6'-0"3'-0" 6'-0"6'-0"4'-0"9'-0" VERIFY EXISTING OPENING AND GLAZING SIZE VERIFY EXISTING OPENING AND GLAZING SIZE 4'-6" 3'-2"10"2'-3" 2'-0"3'-0"2'-4"6'-0"1'-6" K 6'-8"6'-0" VERIFY TUB CLEARANCE PRIOR TO ORDER VERIFY EXISTING OPENING AND GLAZING SIZE TO MATCH 1 2 3 2'-0" 2'-10" 1'-2" 4 53'-0"2'-8" NOTE: ALL EXISTING OPENINGS SHOULD BE MEASURED AND VERIFIED PRIOR TO ORDER, CONFIRM OPERATION. EASED EDGE, RECESSED FENESTRATION STUCCO TO MATCH EXISTING BASE MOULDING TO MATCH EXISTING SINGLE PANEL SOLID CORE DOORS PTD PLASTER VENEER AT DRYWALL CASING TO MATCH EXISTING Stucco edge to match existing caulk int trim to match existing stucco to match existing on stucco wrb 58" plywd sheathing Doors all exterior doors shall be weatherstripped to limit leakage while closed. thermal transfer characteristics of insulated doors shall be determined per IECC Exterior Doors: -1 3 4" Solid Wood Doors w/ wood frame -Double Glazed at lites. -tempered Glazing Interior Doors: -2 panel Masonite, or sim. -Privacy hardware on Bedroom and Bathroom Doors. -Unit Entry, Mechanical, and Garage man-door to be 20 minute, self-closing. Windows Glazing U-values to be .30 or less with a SHGC of .30 or less. these chall be coordinated in accordance with IECC. windows and SGD shall be double glazed woodl type with U-values indicated Windows: Painted wood windows Color TBD Double Glazed - Low-e Argon filled Simulated Divided Lites Tempered Glazing per Elvs. Air Leakage exterior joints at window & door frames, openings at walls and foundations, areas between wall and roof panels, openings and penetrations at utility services through walls, floors and roofs, and any other openings in the building envelope shall be sealed, caulked, gasketed or weatherstripped to limit air leakage. seams shall be taped. Insulation new exterior walls to receive R-28 value spray insulation new roof to receive total cumulative R-49 value insulation IRC 612.3 Window Fall Prevention Devices Mighton Products standard bend lock, both sides < 4" clr w/ locks engaged to meet ASTM F 2090 LOCATED AT WINDOWS LESS THAN 2' FROM FLOOR AND OVER 6' TO GRADE A8.1 SCHEDULESDOOR / WDW SCHED 14" = 1'-0"1 DOOR / WDW TRIM 12" = 1'-0" 2 DOOR / WDW TRIM 11 2" =1'-0"3 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-9208/17/18 B EXISTING INSULATION TO REMAIN EXISTING INSULATION TO REMAIN EXISTING INSULATION TO REMAIN EXISTING INSULATION TO REMAIN EXISTING INSULATION TO REMAIN EXISTING INSULATION TO REMAIN R-49 - ATTIC INSULATION EXISTING ATTIC INSULATION EXISTING ATTIC INSULATION R-49 - ATTIC INSULATION AT NEW CONSTRUCTION R-49 - ATTIC INSULATION AT NEW CONSTRUCTION R-28 - SPRAY WALL INSULATION AT NEW WALLS EXISTING INSULATION TO REMAIN EXISTING INSULATION TO REMAIN EXISTING INSULATION TO REMAIN EXISTING INSULATION TO REMAIN R-28 - SPRAY WALL INSULATION AT NEW WALLS R-28 - SPRAY WALL INSULATION AT NEW WALLS R-28 - SPRAY WALL INSULATION AT NEW WALLS PER RESCHECK TABLE BUILDING AND DUCTWORK MUST UNDERGO LEAKAGE TESTING. THIS PROJECT IS REQUIRED TO SUBMIT AT FINAL INSPECTION A DUCT LEAKAGE TEST SHOWING A PASSING RATING OF <=8 CFM PER 100 SQUARE FEET OF CONDITIONED FLOOR AREA AT A PRESSURE OF 25 PASCAL. A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL UPON REQUEST. SHOW THAT AIR HANDLERS HAVE MANUFACTURERS DESIGNATION FOR LEAKAGE RATE OF <=2%. HVAC LINE-SET PIPING SHALL BE INSULATED WITH FOAM WRAP MIN R-3 THIS PROJECT IS REQUIRED TO SUBMIT AT FINAL INSPECTION A WHOLE-BUILDING BLOWER DOOR TEST SHOWING A PASSING RATING OF <=5 AIR CHANGES PER HOUR AT A PRESSURE OF 50 PASCAL. A WRITTEN REPORT OF THE RESULTS OF THE TEST SHALL BE SIGNED BY THE PARTY CONDUCTING THE TEST AND PROVIDED TO THE CODE OFFICIAL UPON REQUEST. A9.1 THERMAL & DIAGRAMS PLAN DIAGRAMS 3 32"=1'-0"1 1 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-9208/17/18 0 20' 40'NORTH10' C1.0 SITE PLAN 1 APPROXIMATE EDGE OF STREAM (SNOW COVERED) C 2018 GPS Designs LLCISSUE16 August 2018RELEASE Permit - Rev BShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92DECK ADDITION AT REAR HOUSE ADDITION AT REAR 50' STREAM SETBACK FROM CENTER OF STREAM EXISTING DECK EXISTING 2-STORY STONE AND STUCCO HOME 4425 GLEN FALLS LANE FOUND #5 REBAR WITH 1 1 4" PLASTIC CAP STAMPED P.L.S. 26626 GLEN FALLS LANE ( 50' R.O.W. ) LOT 2 LOT 1 LOT 3 6ƒ( 6ƒ: FOUND #5 REBAR WITH 1 1 4" PLASTIC CAP STAMPED P.L.S. 26626 (75' WITNESS CORNER) GORE CREEK LOT 9 LOT 5 PUBLIC PEDESTRIAN/ FISHERMAN'S EASEMENT FOUND #5 REBAR WITH 1 14" PLASTIC CAP STAMPED P.L.S. 26626 (75' WITNESS CORNER) 6ƒ: 1ƒ:  30' SETBACK EXISTING DRIVE, SIDEWALK AND SITE LANDSCAPING TO REMAIN UNCHANGED EXTENT OF CHANGES TO FOOTPRINT, GRADING REMAINS UNCHANGED, NO LANDSCAPING IMPACTS EASEMENT/RIVER 4,610.7sf REAR YARD @ SLOPE 1,263.4sf YARD -FRONT/ WEST 3,178.5sf DECK 841.8sf HOUSE 2,705.6sf DRIVE AND WALK 1,110.4sf YARD -FRONT/ EAST 1,311.5sf TREES -18 PINE -18 ASPEN SITE COVERAGE ALLOWED 35.0% PROVIDED 26.2% calc with 10,330.7sf effective lot area LOT 2 14,941.4sf LANDSCAPED MIN REQUIRED 40.0% PROVIDED 63.8% core development incl. deck at 12.8% effective lot area used in calc. GRADING REMAINS UNCHANGED NEW GROUNDCOVER LANDSCAPING TO RETURN AREAS AFFECTED BACK TO ORIGINAL NO TREES TO BE REMOVED REAR SETBACK FROM BUILDING AND DECK BOTH TO REMAIN UNCHANGED REAR ACCESS ON EAST SIDE OF HOME EXISTING HOMES RESTROOM FACILITIES WILL BE UTILIZED BY WORKERS DEBRIS WILL BE HAULED AWAY IN WHEELED TRAILER. 20 YARD DUMPSTER MAY BE USED SHORT-TERM FOR MAJOR PORTION OF DEMOLTION A LIMIT OF DISTURBANCE ORANGE SAFETY CONSTRUCTION FENCING SEDIMENT FENCE AT ALL AREAS OF EXCAVATION, NO IMPACT TO CREEK LIMIT OF DISTURBANCE CONSTRUCTION FENCING STAKED SEDIMENT FENCE B B 08/17/18 CV1 COVER Project: PROJECT DATA Stan and Carol Shapiro (305) 666-7460 OWNER SHEET INDEX Cover Sheet Site Plan GRFA Analysis Existing Plans Main Level Plan Upper Level Plan Roof Plan Existing Elevations Proposed Elevations Building Sections Building Sections Building Sections Building Sections Perspectives Details Water Protection Details Air Infiltration Details Door/Window Schedule Thermal Information Electrical Layout CV C1.0 A0.1 X1.0 A1.1 A1.2 A1.3 A2.1 A2.2 A3.0 A3.1 A3.2 A3.3 A4.1 A5.1 A5.2 A5.3 A8.1 A9.1 E1.1 SHAPIRO RESIDENCE 4425 Glen Falls Lane EAST VAIL Permit Rev A - Submittal August 3, 2018 Total GRFA : existing - 3,484.0 sf ( plus 537.0 sf in garage ) allowed - 3,750.0 sf ( with additional 250sf ) proposed - 3,729.2 sf ( plus 563.7 sf in garage) Building Height: unchanged Zoning: SDD 27 underlying LD-MF Lot Size: .342 AC ( 14,898 sf ) effective lot area (minus easement) 10,330.7sf Lot Coverage: per underlying zone using effective lot area allowed .350 ( 3,615.7 sf) existing .251 ( 2,589.1 sf) proposed .262 ( 2,705.6 sf) Setbacks: side 15' ( 15' 9" - unchanged ) rear 20' ( 68' 3" - unchanged ) Site: Parcel 2101-123-13-002 FOREST GLEN Lot 2 Address 4425 Glen Falls Lane Vail, Colorado 81657 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92PROJECT LOCATION ADDITION AND INTERIOR RE-FINISH WITH RENOVATION, ELECTRICAL AND PLUMBING. Applicable Code 2015 IRC - Appendix J work area total existing area - 4,021sf 272 sf new construction 651 sf renovation - Main level 833 sf renovation - Upper level 1,756 sf total work area - 43.6% MUNICIPAL 2015 International Existing Building Code all associated ICC codes local amendments per Town Code Code Enforced: Low Density Multi-FamilyOccupancy: V-B, exsitingConstruction Type: Town of Vail Community Development 75 South Frontage Road Vail, Colorado 81657 [p] (970) 479-2138 Planning: existing non-sprinklered, hard wired smoke detectorsFire: R-3, 18.6 OLOccupant Load: GPS Designs LLC 301 Boulder St, 333 Minturn, CO 81645 (970) 470-4945 gregs@gpsdesigns.com Contact: Gregory Sparhawk, aia CO lic 0401016519 ARCHITECT Structural Design Solutions PO Box 2494 Avon, CO 81620 (970) 949-7100 sdsjeff@vail.net Contact: Jeffrey Leonardo STRUCTURAL ENGINEER A SPECIAL INSPECTIONS STEEL WELD AND STRUCTURAL BOLTS INSPECTIONREV Ax x x x 08/17/18 AF AF AF AF AFWP WP WP WP WP GFCI GFCI GFCI GFCI GFCI GFCI GFCI GFCI SURFACE MOUNTED FIXTURE WALL SCONCE FIXTURE SWITCH, ELEC TO DETERMINE POLES, OWNER TO DETERMINE DIMMING HARD WIRED INTER-CONNECTED SMOKE DETECTOR WITH BATTERY BACK-UP TAMPER RESISTANT RECEPTACLE OUTLET - 220V 6 34" RECESSED "CAN" FIXTURE OR SIM. TV CONNECTION GROUND FAULT CIRCUIT INTERUPTER OUTLET EXHAUST FAN / LIGHT COMBO INTER-CONNECTED CO DETECTOR PHONE JACK RECESSED CEILING SPEAKER, TIED TO MEDIA DOCK CAT 6 DUPLEX FLOOR OUTLET TOE KICK LIGHTING LOCATE TIMER IN CAB. AF THERMOSTAT, PROGRAMMABLE AT MAIN ENERGY NOTE: A MINIMUM OF 75% OF LAMPS TO BE OF HIGH-EFFICACY LAMPS HOOD MIN EFFICACY - 2.8cfm/watt EXHAUST FAN MIN EFFICACY - 1.4cfm/watt LUTRON BLUETOOTH REC HOUSE LIGHT NOTE: HOUSE LIGHT WILL BE SWITCHED WITH MOTION AT THE GARAGE DOORS. LIGHT SENSOR AT EXTERIOR SCONCES ARC FAULT OUTLET NOTE: ALL BRANCH CIRCUITS FEEDING ALL OUTLETS IN FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, DENS, BEDROOMS, CLOSETS, HALLWAYS, AND SIMILAR ROOMS OR AREAS. MUST BE INSTALLED FIRST IN LINE. E1.1 ELECTRIC PLANS ELECTRIC - Plans n.t.s. 1 GENERAL ELECTRICAL SPECIFICATIONS: 1.1 SPECIAL N0TICE A. EACH CONTRACTOR SHALL READ ALL RELEVANT DOCUMENTS, BECOME FAMILIAR WITH THE JOB, THE SCOPE OF WORK, TYPE OF GENERAL CONSTRUCTI0N, ARCHITECTURAL, STRUCTURAL, MECHANICAL AND ELECTRICAL DRAWINGS AND THE SPECIFLCATI0NS. EACH CONTRACTOR SHALL ALSO FAMILIARIZE HIMSELF WITH THE PURPOSE FOR WHICH THESE DRAWINGS HAVE BEEN PREPARED AND SHALL BECOME COGNIZANT OF ALL THE DETAILS INVOLVED. B. THE TERM "CONTRACTOR" USED IN THIS SECTI0N OF SPECIFICATIONS SHALL MEAN THE CONTRACTOR WHOSE WORK IS COVERED BY THAT SECTION. C. WHEN THE TERM "ENGINEER" IS USED IN THIS SECTI0N OF SPECIFICATO0N IT SHALL MEAN THE CONSULTING ELECTRICAL ENGINEER. 1.2 SCOPE OF WORK A. THE WORK UNDER THIS SECTI0N OF THE SPECIFICATIONS SHALL INCLUDE ALL LABOR AND MATERIALS NOTED, REQUIRED OR NECESSARY FOR THE COMPLETE ELECTRICAL INSTALLATION DESCRIBED HEREIN AND/OR ON THE DRAWINGS. ALL WORK SHALL BE COMPLETED TO THE ENTIRE SATISFACTION OF THE OWNER AND ENGINEER. B. THIS WORK INCLUDES, BUT IS NOT LIMITED TO THE FOLLOWING: 1. ELECTRIC SERVICE AND METERING HEREINAFTER SPECIFIED INCLUDING FEES, PERMITS AND PROVISIONS FOR METERING EQUIPMENT AS AGREED TO BY OWNER AND CONTRACTOR. 2. COMPLETE SYSTEMS OF DISTRIBUTI0N AND UTILIZATION FOR LIGHT AND POWER (WITHIN THE JOB SITE) 3. EMPTY CONDUIT SYSTEM FOR TELEPHONES. POWER, COMMUNICATION, ETC. 4. LIGHTING FIXTURES AND LAMPS. 5. ROUGH-IN AND FINAL CONNECTIONS TO MECHANICAL EQUIPMENT. 6. ROUGH-IN AND FINAL CONNECTION TO CONTRACTOR'S AND OWNER'S FURNISHED EQUIPMENT. 1.3 ELECTRICAL SERVICE A. THIS CONTRACTOR SHALL CONTACT THE LOCAL POWER COMPANY AND MAKE ALL ARRANGEMENTS, PAY ALL FEES, AND ACQUIRE ALL PERMITS AS REQUIRED FOR THE INSTALLATION OF THE ELECTRICAL SERVICE AND SYSTEMS AS HEREINAFTER SPECIFIED. B. THE LOCAL POWER COMPANY WILL MAKE ALL TERMINATION'S TO THE TRANSFORMERS. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL SECONDARY ELECTRICAL SERVICE AS REQUIRED BY LOCAL UTILITY COMPANY. C. THE ELECTRICAL CONTRACTOR SHALL ALSO MAKE ALL PROVISIONS WHICH MAY BE REQUIRED BY THE SERVICING UTILITY COMPANIES. 1.4 FEES AND PERMITS A. EACH CONTRACTOR SHALL OBTAIN ALL PERMITS. INSPECTI0NS, AND APPROVALS APPLICABLE TO HIS TRADE, AS REQUIRED BY REGULATORY AUTHORITIES. ALL FEES AND COSTS OF ANY NATURE WHATSOEVER INCIDENTAL TO THESE PERMITS, INSPECTI0NS AND APPROVALS SHALL BE ASSUMED AND PAID BY THE CONTRACTOR, EXCEPT FOR METERS. THE OWNER WILL PAY FOR METERS AS REQUIRED. THE GENERAL BUILDING PERMIT WILL BE OBTAINED UNDER OTHER SECTI0NS OF THE WORK AND THAT PORTI0N OF THE COSTS INVOLVED IN OBTAINING THIS PERMIT WILL BE PAID BY THE CONTRACTOR FOR THE ELECTRICAL TRADE. THE PRO-RATED COSTS. IF ANY, OR UTILITIES SERVING THIS PROPERTY WILL BE PAID FOR BY THE OWNER AND SHALL NOT BE INCLUDED AS PART OF THIS CONTRACT. 1.5 CODES AND STANDARDS A. ALL MATERIALS AND WORKMANSHIP SHALL COMPLY WITH ALL APPLICABLE LOCAL, COUNTY. STATE AND NATI0NAL CODES, SPECIFLCATI0NS, ORDINANCES, UTILITY COMPANY REGULATI0NS AND SPECIFIED INDUSTRY STANDARDS. B. IN CASE OF DIFFERENT BETWEEN BUILDING CODES, SPECIFLCATI0NS, STATE LAWS, LOCAL ORDINANCES, INDUSTRY STANDARDS AND UTILITY COMPANY REGULATIONS AND THE CONTRACT DOCUMENTS. THE MOST STRINGENT SHALL GOVERN. THE WORK INVOLVED WITH THESE DIFFERENCES SHALL BE PERFORMED AT NO ADDITIONAL COST TO THE OWNER. C. IN ADDITION TO THE ABOVE, IF THE FOLLOWING INDUSTRY STANDARDS AND CODES ARE MORE STRINGENT, THEY SHALL TAKE PRECEDENCE. IEEE - INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS IES - ILLUMINATING ENGINEERING SOCIETY NEC - NATIONAL ELECTRIC CODE NEMA - NATIONAL ELECTRIC MANUFACTURER'S ASSOCLATION NFPA - NATIONAL FIRE PROTECTI0N ASSOCLATION UL - UNDERWRITER'S LABORATORIES D. ALL WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER. ANY WORK FOUND TO BE UNSATISFACTORY, BY THE ENGINEER, LOCAL AUTHORITIES, OR OWNER, SHALL BE REMOVED AND REINSTALLED IMMEDIATELY AT NO ADDITIONAL COST. E. ANY AND ALL INSTALLATION OF ELECTRICAL CONDUCTORS AND APPARATUS SHALL BE PERFORMED BY SKILLED AND PROPERLY LICENSED JOURNEYMEN. ANY UNLICENSED PERSON FOUND PERFORMING SUCH WORK SHALL BE DISMISSED AND ANY WORK PERFORMED BY THAT PERSON SHALL BE REPLACED. 1.6 MANUFACTURERS DIRECTIONS A. THE MANUFACTURERS' PUBLISHED DIRECTI0NS SHALL BE FOLLOWED IN THE DELIVERY, STORAGE, PROTECTI0N, INSTALLATION, PIPING AND WIRING OF ALL EQUIPMENT AND MATERIAL SHOULD THE CONTRACTOR PERFORM ANY WORK THAT DOES NOT COMPLY WITH THE MANUFACTURERS' DIRECTI0NS OR INSTRUCTI0NS FROM THE OWNER, HE SHALL BEAR ALL COSTS ARISING IN CONNECTI0N WITH DEFICIENCIES. 1.7 SUBMITTAL DATA A. SEE SPECIFICATIONS 1.8 EQUIPMENT IDENTIFICATION A. ALL MAJOR EQUIPMENT SUCH AS PANEL BOARDS, DISCONNECTS, AND OTHER SIMILAR EQUIPMENT SHALL BE IDENTIFIED BY THE ATTACHMENT OF NAME PLATES. B. COMPLETE ALL IDENTIFICATION CARDS FOR SWITCHES, STARTERS, AND OTHER DEVICES IN ALL PANEL BOARDS. AND SIMILAR PIECES OF EQUIPMENT, WRITTEN IN A READABLE. NEAT MANNER AND INSERT THE CARD IN THE CARD HOLDERS BEHIND A SHEET OF CLEAR PLASTIC. 1.9 RECORDS FOR THE OWNER A. EACH CONTRACTOR SHALL OBTAIN AT HIS OWN EXPENSE A COMPLETE SET OF BLUE LINE PRINTS ON WHICH HE SHALL KEEP AN ACCURATE RECORD OF THE INSTALLALL0N OF ALL MATERIALS AND SYSTEMS COVERED BY HIS CONTRACTUAL AGREEMENT. THE RECORD SHALL INDICATE THE LOCATION OF ALL EQUIPMENT AND THE ROUTING OF ALL SYSTEMS, ALL CONDUIT BURIED IN CONCRETE SLABS, WALLS, AND BELOW GRADE SHALL BE LOCATED BY DIMENSION UNLESS A SURFACE-MOUNTED DEVICE IN EACH SPACE INDICATES THE EXACT LOCATION. HE SHALL THEN OBTAIN AT HIS EXPENSE ONE COMPLETE REPRODUCIBLE SET OF THE ORIGINAL DRAWINGS ON WHICH HE SHALL NEATLY TRANSFER HIS NOTATI0NS AND DELIVER THESE DRAWINGS TO THE ENGINEER AT JOB COMPLETI0N BEFORE FINAL PAYMENT FOR DELIVERY TO THE OWNER. B. IN ADDITION TO THE ABOVE, EACH CONTRACTOR SHALL ACCUMULATE DURING THE JOB PROGRESS THE FOLLOWING DATA IN DUPLICATE PREPARED IN A NEAT BROCHURE OR PACKET FOLDER AND TURN OVER TO THE ENGINEER AND OWNER FOR CHECKING, BINDING AND SUBSEQUENT DELIVERY TO THE OWNER. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID THE COST OF BINDING INTO A BOOK. 1. ALL WARRANTIES AND GUARANTEE AND MANUFACTURERS' DIRECTI0NS ON EQUIPMENT AND MATERIAL COVERED BY THE CONTRACT. 2. COPIES OF APPROVED SHOP DRAWINGS. 1.10 ELECTRICAL ENERGY, WATER AND SANITARY FACILITIES A. ELECTRICAL ENERGY, WATER AND SANITARY FACILITIES REQUIRED FOR THE CONSTRUCTION OF THIS PROJECT SHALL BE PROVIDED AS HEREIN BEFORE SPECIFIED UNDER THE ARCHITECTURAL SECTIONS OF THE WORK 1.11 SUPERVISION A. EACH CONTRACTOR SHALL KEEP A COMPETENT SUPERINTENDENT OR FOREMAN ON THE JOB AT ALL TIMES AND SHALL BE FULLY RESPONSIBLE FOR THE SUPERVISION OF HIS WORK. PERIODIC VISITATIONS TO THE PROJECT BY THE ENGINEER, COMMONLY REFERRED TO AS OBSERVATIONS, ARE ONLY FOR THE EXPRESS PURPOSE OF VERIFYING COMPLIANCE BY THE CONTRACTOR WITH THE CONTRACT DOCUMENTS. SUCH VISITATIONS BY THE ENGINEER SHALL NOT BE CONSTRUED TO MAKE THE ENGINEER RESPONSIBLE FOR PROVIDING A SAFE PERFORMANCE OF THE WORK BY THE CONTRACTOR OF THE CONTRACTOR'S EMPLOYEES OR THE SAFETY OF THE SUPPLIES OF THE CONTRACTOR OR HIS SUB-CONTRACTORS. 1.12 DRAWINGS AND SPECIFICATIONS A. THE DRAWINGS SHOW DIAGRAMMATICALLY THE LOCATIONS OF THE VARIOUS LINES, DUCTS, CONDUITS, FIXTURES, AND EQUIPMENT AND THE METHOD OF CONNECTING AND CONTROLLING THEM. IT IS NOT INTENDED TO SHOW EVERY CONNECTION IN DETAIL AND ALL FITTINGS REQUIRED FOR A COMPLETE SYSTEM. THE SYSTEMS SHALL INCLUDE BUT ARE NOT LIMITED TO THE ITEMS SHOWN ON THE DRAWINGS. EXACT LOCATIONS OF THESE ITEMS SHALL BE DETERMINED BY REFERENCE TO THE GENERAL PLANS AND MEASUREMENTS AT THE BUILDING AND IN COOPERATION WITH THE OTHER SUBCONTRACTORS, AND IN ALL CASES, SHALL BE SUBJECT TO THE APPROVAL OF THE ENGINEER AND OWNER. THE OWNER RESERVES THE RIGHT TO MAKE ANY REASONABLE CHANGE IN THE LOCATION OF ANY PART OF THIS WORK WITHOUT ADDITIONAL COST TO THE OWNER. B. SHOULD ANY CHANGES BE DEEMED NECESSARY BY THE CONTRACTOR IN ITEMS SHOWN ON THE CONTRACT DRAWINGS, THE SHOP DRAWINGS, DESCRIPTIONS AND THE REASON FOR THE PROPOSED CHANGES SHALL BE SUBMITTED TO THE ENGINEER AND OWNER FOR APPROVAL C. EXCEPTIONS AND INCONSISTENCIES IN PLANS AND SPECIFICATIONS SHALL BE BROUGHT TO THE OWNER'S ATTENTION BEFORE BIDS ARE SUBMITTED; OTHERWISE, THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE COST OF ANY AND ALL CHANGES AND ADDITIONS THAT MAY BE NECESSARY TO ACCOMMODATE HIS PARTICULAR APPARATUS. D. THE CONTRACTOR SHALL LAY OUT HIS WORK MAINTAINING ALL LINES, GRADES AND DIMENSIONS ACCORDING TO THESE DRAWINGS WITH DUE CONSIDERATION FOR OTHER TRADES AND VERIFY ALL DIMENSIONS AT THE SITE PRIOR TO ANY FABRICATION OR INSTALLATION. SHOULD THE LAYOUT BE IMPRACTICAL, THE OWNER SHALL BE NOTIFIED BEFORE ANY INSTALLATION OR FABRICATION, AND THE EXISTING CONDITIONS SHALL BE INVESTIGATED AND PROPER CHANGES EFFECTED WITHOUT ADDITIONAL COST. E. TITLES OF SECTIONS AND PARAGRAPHS IN THESE SPECIFICATIONS ARE INTRODUCED MERELY FOR CONVENIENCE AND ARE NOT TO BE CONSTRUED AS A CORRECT OR COMPLETE SEGREGATION TO TABULATION OF THE VARIOUS UNITS OF MATERIALS AND/OR WORK. THE OWNER DOES NOT ASSUME ANY RESPONSIBILITY, EITHER DIRECT OR IMPLIED, FOR OMISSIONS OR DUPLICATIONS BY THE CONTRACTOR OR ANY SUBCONTRACTOR, DUE TO REAL OR ALLEGED ERROR IN THE ARRANGEMENT OF MATTER IN THE CONTRACT DOCUMENTS. F. DIFFERENT ELECTRICAL OUTLETS, DEVICES, ETC. ARE INDICATED BY SYMBOLS SCHEDULED ON THE DRAWINGS. APPROXIMATE LOCATIONS ARE SHOWN; HOWEVER, THE DESIGN TEAM RESERVES THE RIGHT TO MAKE REASONABLE CHANGES IN LOCATIONS WITHOUT ADDITIONAL COSTS. G. LINES INDICATING BRANCH CIRCUITS DO NOT SHOW EXACT ROUTING BUT INDICATE THE ARRANGEMENT AND CONTROL OF CIRCUITS. CONCEAL RACEWAYS (UNLESS NOTED OTHERWISE) AND RUN IN MOST DIRECT MANNER BETWEEN CABINETS, OUTLETS, ETC. GENERAL NOTES: A. THE ELECTRICAL INFORMATION SHOWN ON THIS PLAN IS BASED UPON THE LATEST INFORMATION AVAILABLE FROM THE RESPECTIVE UTILITY COMPANIES. IT IS INTENDED FOR PURPOSES OF GENERAL BIDDING AND BASIC CLARITY. SPECIFIC JOB SITE CONDITIONS SHALL BE FIELD VERIFIED PER NOTES 'B' THROUGH 'E' BELOW. THE ELECTRICAL CONTRACTOR SHALL ASSUME ALL RESPONSIBILITY FOR SAID FIELD CONDITIONS AND ANY ASSOCIATED CHANGES REQUIRED BY THE RESPECTIVE UTILITY COMPANIES INVOLVED. B. THE ELECTRICAL CONTRACTOR SHALL CONTACT THE ELECTRICAL UTILITY, AND VERIFY ALL REQUIREMENTS AND EQUIPMENT, AND PROVIDE ALL WIRING, BOXES, CONDUIT, CONCRETE PADS, TRENCHING AND BACKFILL, ETC. NECESSARY FOR PROPER INSTALLATION, PAY ALL FEES AND CHARGES INCURRED, COORDINATE WITH ELECTRICAL UTILITY. C. THE ELECTRICAL CONTRACTOR SHALL CONTACT THE TELEPHONE UTILITY, VERIFY ALL REQUIREMENTS AND EQUIPMENT, AND FURNISH AND INSTALL ALL WIRING, BOXES, CONDUIT, GROUNDING, CONCRETE PADS, TRENCHING AND BACKFILL, ETC., NECESSARY FOR PROPER INSTALLATION. PAY ALL FEES AND CHARGES INCURRED. COORDINATE WITH TELEPHONE UTILITY. D. THE ELECTRICAL CONTRACTOR SHALL FIELD VERIFY. IN THE PRESENCE OF THE RESPECTIVE UTILITY COMPANY REPRESENTATIVES, THE LOCATIONS OF ALL EXISTING UTILITY SERVICES AND EQUIPMENT, AND THE PROPOSED LOCATIONS OF ALL NEW UTILITY SERVICES AND EQUIPMENT. THE ELECTRICAL CONTRACTOR SHALL INCLUDE IN HIS BID SUFFICIENT FUNDS TO COVER ALL COSTS REQUIRED BY UTILITY COMPANIES TO PROVIDE NEW SERVICES AND/OR UPGRADE EXISTING SERVICES. NO ALLOWANCES WILL BE MADE FOR THE ELECTRICAL CONTRACTOR'S UNFAMILIARITY WITH THE EXIST1NG CONDITIONS, REQUIREMENTS OF THE NEW CONDITIONS, AND/OR FAILURE TO COORDINATE INSTALLATION WITH THE RESPECTIVE UTILITY. E. THE ELECTRICAL CONTRACTOR SHALL CONTACT THE LOCAL ELECTRICAL CODE ENFORCEMENT AUTHORITIES AND THE LOCAL FIRE MARSHAL, VERIFY ALL REQUIREMENTS AND EQUIPMENT. AND FURNISH AND INSTALL ALL ELECTRICAL ITEMS NECESSARY FOR PROPER INSTALLATION IN STRICT ACCORDANCE WITH THE GUIDELINES AND INTERPRETATIONS SET FORTH BY THESE GOVERNING LOCAL AUTHORITIES, ABOVE AND BEYOND ALL THE BASIC ELECTRICAL AND FIRE ALARM REQUIREMENTS SET FORTH IN THE NEC AND NFPA. NO ALLOWANCES WILL BE MADE FOR THE ELECTRICAL CONTRACTOR'S FAILURE TO COORDINATE ALL SUCH REQUIREMENTS WITH SAID LOCAL AUTHORITIES. F. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL SITE LIGHTING AS REQUIRED BY OWNER AND OWNER'S LANDSCAPE LIGHTING DESIGNER, SITE LIGHTING SHALL BE INSTALLED TO PROVIDE A MINIMUM N.A.I.E.S. STANDARDS OF ONE-QUARTER (1/4) FOOT-CANDLE AVERAGE MAINTAINED ON PAVED, UNENCLOSED OR UNSHELTERED DRIVING SURFACES. PROVIDE BUILDING-MOUNTED FLOOD LIGHTS. POLE LIGHTS AND OTHER SITE LUMINARIES INDICATED ON SITE PLAN ELECTRICAL SYMBOLS LEGEND IN LOCATIONS SHOWN. HOMERUN THRU PHOTOCELL TO NEAREST OWNERS PANEL G. THE ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL J-BOXES, POWER, CONTROL AND RELATED COMMUNICATIONS WIRING IN CONDUIT PLUS ALL FINAL CONNECTIONS FOR ALL ID SIGNS, SECURITY GATES, CARD PEDESTALS, ETC. H. HOMERUN SITE LIGHTING CIRCUITS THROUGH PHOTOCELL RELAY TO 20A/1P CIRCUIT BREAKER IN NEAREST OWNER'S PANEL OR CLUBHOUSE PANEL I. LOCATIONS OF ALL POST LIGHTS, WALKWAY DECOR LIGHTS, AND OTHER LANDSCAPE LIGHTING SHALL BE FIELD VERIFIED PRIOR TO INSTALLATION WITH LANDSCAPE ARCHITECT AND OWNER'S REPRESENTATIVE. LOCATIONS SHOWN ON THIS SMALL SCALE PLAN ARE APPROXIMATE ONLY. J. ALL ELECTRICAL WORK SHALL CONFORM TO THE LATEST EDITION OF THE NATIONAL ELECTRIC CODE, NFPA 70, AS ENFORCED BY THE AUTHORITIES HAVING JURISDICTION. K. WHERE A FIRE ALARM SYSTEM OR SYSTEMS ARE REQUIRED, PROVIDE APPROPRIATE CONSTRUCTION CONFORMING TO THE LATEST EDITION OF THE NATIONAL FIRE PROTECTION ASSOCIATION FIRE ALARM CODE, NFPA 72, AND ALL LOCAL CODES AS ENFORCED BY THE AUTHORITIES HAVING JURISDICTION. L THE ELECTRICAL CONTRACTOR SHALL INCREASE ONE SIZE UP TO ALL CONDUCTORS FOR EVERY 75 LFT. IN ORDER TO PREVENT A VOLTAGE DROP EXCEEDING 3% AT THE FARTHEST OUTLET OF POWER, HEATING AND LIGHTING LOADS, OR COMBINATION OF SUCH LOADS, AND WHERE THE MAXIMUM TOTAL VOLTAGE DROP ON BOTH THE FEEDERS AND BRANCH CIRCUITS TO THE FARTHEST OUTLET DOES NOT EXCEED 5%, WILL PROVIDE REASONABLE EFFICIENCY OF OPERATION. IF ELECTRICAL CONTRACTOR CAN NOT DETERMINE THE VOLTAGE DROPS OR PROPER CONDUCTOR SIZE, CONTACT THE ELECTRICAL ENGINEER FOR ASSISTANCE. A. ALL ELECTRICAL OUTLETS, LIGHT FIXTURES, FANS, SWITCHES, ETC.. SHALL COMPLY WITH THE 2008 NEC. & AS AMENDED BY THE LOCAL CITY CODES. B. OWNER TO COORD. LOC. OF GAS, WATER & ELECTRICAL METER & PANEL LOCATIONS. C. TYP. OUTLETS TO BE INSTALLED AT +16" A.F.F. U.N.O. - VERIFY W/ OWNER. OUTLETS INDICATED AT COUNTERS ARE TO BE INSTALLED AT +44" A.F.F. U.N.O. - OUTLETS INDICATED AT ENT. CENTERS ARE TO BE COORD. W/ MILLWORK SUBCONTRACTOR & AUDIO VISUAL CONSULTANT. D. OUTLETS IN FLOORS & TEL. JACKS ARE TO BE FIELD VERIFIED FOR LOC. BY OWNER. E. COORD. OUTLETS, TEL. JACKS, ETC.. AT HOME CENTER & STUDY. F. TWO OR MORE 20-AMPERE SM. APPLIANCE BRANCH CIRCUITS SHALL BE PROVIDED FOR ALL RECEPTACLE OUTLETS LOCATIONS IN KITCHEN, PANTRY, NOOK, DINING RM. OR SIM. AREA. THESE CIRCUITS MUST SERVE NO MORE THAN (3) OUTLETS EA. & HAVE NO OTHER OUTLETS CONNECTED. RE: 210-52B & 220-4B '02 NEC. G. INSTALL ONE GFI OUTLET ADJACENT TO EACH BASIN IN ALL BATHROOMS. BATHROOM OUTLET(S) SHALL BE SUPPLIED BY AT LEAST ONE 20-AMPERE BRANCH CIRCUIT. SUCH CIRCUITS SHALL HAVE NO OTHER OUTLETS CONNECTED. RE: 210-52D, & 210-8 '08 NEC. H. OUTLETS IN THE FOLLOWING LOC. ARE TO HAVE GFI PROTECTION; BATHROOMS, GARAGES, OUTDOORS, UNF. BASEMENTS, KITCHENS, LAUNDRY SINKS. RE: 210-52, & 210-8 '08 NEC. I. GAS LOG OR FIREPLACE: SHALL REQUIRE A MANUAL SHUT-OFF VALVE LOCATED WITHIN 4' OF THE FIREBOX, ACCESSIBLE TO THE ROOM IN WHICH THE APPLIANCE IS LOCATED. OUTSIDE COMBUSTION AIR MUST BE PROVIDED DIRECTLY TO THE FIREBOX. RE: 2009 I.M.C. J. A MAXIMUM OF 8 ELECTRICAL OUTLETS MAY BE CONNECTED TO A 15 AMPERE BRANCH CIRCUIT OR 10 ELECTRICAL OUTLETS MAY BE CONNECTED TO A 20 AMPERE BRANCH CIRCUIT, PER 220-3 '08 NEC K. LIGHT FIXTURES IN CLOTHES CLOSETS MUST COMPLY WITH 410-8 '08 NEC L. THE GROUNDING ELECTRODE SYSTEM SHALL INCLUDE AN ELECTRODE ENCASED BY AT LEAST 2" OF CONCRETE, LOCATED WITHIN AND NEAR THE BOTTOM OF A CONCRETE FOUNDATION OR FOOTING THAT IS IN DIRECT CONTACT WITH THE EARTH, CONSISTING OF AT LEAST 20 FT. OF ONE OR MORE BARE OR ZINC GALVANIZED OR OTHER ELECTRICALLY CONDUCTIVE COATED STEEL REINFORCING BARS OR RODS OF NOT LESS THAN 1/2" DIA., OR CONSISTING OF AT LEAST 20 FT. OF BARE COPPER CONDUCTOR NOT SMALLER THAN NO.2. 250-50 (C). RE: '08 NEC M. FIELD VERIFY ALL POWER AND CABLE REQUIREMENTS WITH OWNER AT ENTERTAINMENT AND HOME MANAGEMENT CENTERS. N. COORD. OPTIONAL CAT-6 OR EQUAL PRE-WIRE UPGRADE THROUGHOUT HOME WITH OWNER. First Floor Second Floor C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92SWITCH FOR NEW DIRECT VENT GAS FIREPLACES 1) ELECTRIC SHOWN TO COORDINATE WITH EXISTING SERVICES AND CIRCUITS. 2) TIE NEW CIRCUITS INTO EXISTING BREAKERS, I.E. ALL NEW MASTER BATH CIRCUITS TO TIE INTO EXISTING MASTER BATH BREAKER AT PANEL. 3) NOTIFY OWNER AND ARCHITECT IF EXISTING BREAKER LOADS ARE INSUFFICIENT. 4) PROVIDE/ CONFIRM SMOKE DETECTORS AT ALL BEDROOMS. 5) PROVIDE CO2 DETECTORS LOCATE PER MANUFACTURERS RECOMMENDATION 6) VENT ALL BATH FANS TO EXTERIOR. 7) CABLE/POWER FOR TELEVISIONS IS ASSUMED, CONTRACTOR TO VERIFY OWNERS SELECTED SYSTEM AND COORDINATE PROPER WIRING. COORDINATE LOCATION WITH INTERIORS PACKAGE UTILIZE EXISTING EXHAUST FAN AT EXISTING POWDER ROOM ROUGH-IN FOR PENDANT FAN WITH LIGHT TIE INTO EXISTING STAIR AND HALL LIGHTING TIE INTO EXISTING BEDROOM LIGHTING TIE INTO EXISTING BEDROOM LIGHTING 08/17/18 Special inspections required for all high strength bolting and welds 08/17/18 08/17/18 08/17/18 08/17/18 08/17/18 X1.0 EXISTING FLOOR PLANSMAIN LEVEL 3 16" = 1'-0"1 UPPER LEVEL 3 16" =1'-0"2 C 2018 GPS Designs LLCISSUE6 July 2018RELEASE PermitShapiro ResidenceStan and Carol Shapiro4425 Glen Falls LaneVail, Colorado 81657PROJECTShapiro AdditionPROJECT NO.17_SR-0002301 Boulder St, #333 Minturn CO 81645 970 470 4945 Forest Glen Lot 2BK 587 PG 376 MAP 08-19-92GARAGE FAMILY RM KITCHEN DINING FAMILY LIVING ENTRY PANTRY POWDER 34 BATH LANDING MASTER BED M BATH BED 2 BATH LAUNDRY BATH BATH BED 4 BED 3 CLO CLO CLO DECK DECK EXISTING BATHROOM TO SHIFT OUT TO AREA OF NEW ADDITION. NEW BATHTUB TO BE ADDED. EXISTING BATHROOM TO BE RECONFIGURED. REPLACING BATH/SHOWER WITH SHOWER ONLY. ADDING ONE ADDITIONAL SINK. EXISTING BATHROOM TO BE RECONFIGURED INTO NEW AREA NO NET INCREASE IN FIXTURES. EXISTING POWDER ROOM TO BE RECONFIGURED. REMOVING SHOWER REDUCING FIXTURE COUNT. MECHANICAL SHIFT EXISTING RADIANT BASEBOARD HEAT INTO NEWLY SHIFTED BEDROOM EXTEND EXISTING RADIANT FLOOR HEATING AT BATHROOM MOVE EXISTING RADIANT BASEBOARD HEAT INTO NEWLY SHIFTED REAR WALL AT WINDOWS. EXISTING CHIMNEY TO BE REMOVED HATCH SHOWS AREAS OF MAIN DEMOLITION, ADDITIONAL SMALLER AREAS NEEDED FOR WINDOWS/DOORS PER PLANS 08/17/18