Loading...
HomeMy WebLinkAboutB18-0315_Approved Documents_1533915975.pdfi;) Proposal Sundance Plumbing & Heating PO Box 3684 6/1/18 Childrens Garden of Leaming 129 North Frontage Road Vail, CO Re: Boiler Replacement Avon, CO 81620 748-8977 office sph@vail.net Sundance Plumbing and Heating is pleased to provide the following proposal. We will provide all labor and material necessary to complete the following work: 1) Add system cleaner and flush prior to removing existing boiler 2) Remove and recycle existing boiler. 3) Furnish and install a Lochinvar KHN 199 boiler. 199,000 Btu's 12 year Limited Heat Exchanger Warranty 1 year Parts Warranty 96% Efficiency 4) Install new boiler piping connected to existing piping. 5) Install new expansion tank. 6) Install new air separator, auto fill and backflow. 7) Furnish and install new Grundfos, boiler and system pumps, with isolation valves. 8) Install new PVC combustion and exhaust air piping to outside. 9) Install new boiler condensate drain line with Axiom neutralizer. 10) Remove and replace all existing zone valves, zone valves located in class rooms behind access panels. 11) Existing water heater to be reused, connected to new boiler to allow for domestic hot water priority. 12) Install all necessary 24 volt low voltage wiring and 120 volt wiring to boiler and pumps. 13) Flush heating system and fill with a 30% solution ofglycol. , 14) This proposal includes 12 month parts and labor warranty and 12 month buiier service plan. 15) This proposal does not include Town ofVail permit. .. 5 psi test req'd on existing or new exhaust pipe 08/10/18 Price: $18,574.00 Sundance Plumbing & Heating Ken Netzeband Owner Ill 08/10/18 -W:-Locbinvar®KNIGHT Wall Mount HEATING BOILER HIGH EFFICIENCY BOILERS & WATER HEATERS Submittal Sheet WHN-Sub-05 KNIGHT® WALL MOUNT HEATING BOILERS JOB NAME ~--------------------------------------~LOCATION ~--------------------------------------~ ENGINEER ·~--------------------------------------WHOLESALER ~------------------------------------~ MECH. CONTRACTOR ~--------------------------------~ MODEL NO. ~--------------------------------------- TYPE GAS Btu/hr INPUT ~---------------------------------------Btu/hr OUTPUT NOTES ~------------------------------------~ AIR VENT RIGHT LOW VOLTAGE ELECTRICAL OUTLET HIGH VOLTAGE ELECTRICAL CONNECTIONS CONDENSATE DRAIN BOTTOM ~ 33-1/4" 18-lft 16" 11-3/4" rr 3-1/2" 3-3/4'' 1-1/2" 3" &-1/8" 7-114'' 3-3/4" &-1/2"4-1/2" a-112· 112" 1" t t 139 33-1/4" 18-1/2" 16" 11-3/4" rr 3-1/t 3-3/4'' 1-1/2" 3" &-1/8" 7-1/4" 3-3/4" B-1/t 4-1/2" a-11r 112" 1" 2" 2" 142 33-1/4" 18-1/2" 19'' 14-1/2" 8-3/2" 5" 7-3/4" 1-1/8" 12-3/8" 4-1/4" 11-1/4" J" 5-1/4" 5-1/8'' 10" 1/2" 1" 3" 3" 159 33-1/4" 18-1/2" 19" 14-1/2" 8-1/2" 5" 7-3/4" 1-1/8" 12-3/8" 4-/14'' 11-1/4'' 3" 5-1/4'' 5-1/8" 10" 1/2" 1" J" J" 166 33-1/4" 18-1/2" 19" 14-1/2" 11" 6-1/4" 7-3/4" 1-1/2" 12-3/8" 4-1/4'' 9-1/l" 3" 5-1/4" 5-1/2" 10-3/4" 1/l' 1-1/4'' 3" -r-175 28.5 95 264 33-1/4" 18-1/2" 21-3/4" 16-1/2" 11-1/8" 6-1/4" 7-3/4'' 1-112'' 12-3/8" 16-3/8" 12-1/4" 3-1/8" 5-1/4"4" 15-1/8" 1/2" 1-1/4" J" 3" 184 ,_____ 39_9__ 8_o__ 9_4.4_*___ 37_7# _ _ 32_8_.-35.:!/2.'.'._~__B::!L~'._!Z:lltJ±:!f.2.'.'.1:1'~'~.9:11r±:_11~::. 1}:!!~'._..2]:!/2.'.'...L __'.!:!L~'._4'.____~:!fl"}~~·.-1~'.__.l:Jl2:.__4'.'... *Thermal Efficiency% #Gross Output MBH **10:1 Turndown ratio and top and bottom water connections are not included on WHN400. WHN400 operates with a 5:1 turndown. Information ~ubjett to cr,ange without notice. Change ''N" to "l" fur LP models. !he a boiie1· for re-qu1rerrent<;, 4'' 213 08/10/18 FIRING (ODES >M9 Standard Construction >M7 California Code SMART SYSTEM FEATURES >Smart System Digital Operating Control Multi-Color Graphic LCD Display w/Navigation Dial, Soft Keys and Loch-N-Linkā„¢ USBprogramming >Three Boiler Setpoint Temperature Inputs Plus Domestic Hot Water Prioritization >Built-in Cascading Sequencer for up to 8 Boilers, with Cascade Redundancy Multiple Size Boiler Cascade Lead Lag Efficiency Optimization Front End Loading Capability >Outdoor Reset Control with Outdoor Air Sensor Programmable for Three Reset Temperature Inputs >Programmable System Efficiency Optimizers SH Night Setback DHWNight Setback Anti-Cycling Outdoor Air Reset Curve Ramp Delay Modulation Factor Control BoostTemperature & Time >Four Pump Control System Pumpwith Parameter for Continuous Operation Boiler Pumpwith Variable Speed Control Domestic HotWater Pump Domestic HotWater Recirculation >Domestic Hot Water Prioritization DHWtank piped with priority inthe boiler loop DHWtank piped asazone in the system with the pumps controlled bythe SMARTSYSTEM DHWModulation Limiting Separately Adjustable Space Heat/DHW Switching Times >Building Management System Integration 0-10VDCInput to Control Modulation or Setpoint 0-10VDC Modulation Rate Output 0-10VDCInput to Enable/Disable Call for Heat >Access to BMSSettings through Graphic LCDDisplay >High-Voltage Terminal Strip 120VAC/ 60 Hertz/ 1Phase Power Supply Three Sets of Pump Contacts >Low-Voltage Terminal Strip DHW Recirculation Pump Start/Stop 24 VACDevice Relay Proving Switch Contacts FlowSwitch Contacts Alarm on Any Failure Contacts Runtime Contacts DHWThermostat Contacts 3 Space HeatThermostat Contacts System Sensor Contacts DHWTank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10VDCBMS External Control Contact 0-10VDC Boiler Rate Output Contacts 0-10VDCVariable Speed System Pump Signal Input 0-10VDCSignal to Control Variable Speed Boiler Pump ModbusContacts >Time Clock >Data Logging Hours Running, Space Heating Hours Running, Domestic HotWater Ignition Attempts Last10Lockouts >Maintenance Reminder Custom Maintenance Reminder withContractor Contact Information Installer Ability to De-activate Service Reminder >Low-Water Flow Safety Control & Indication >Password Security >Customizable Freeze Protection Parameters STANDARD FEATURES >ENERGYSTAR Most Efficient Product >95°/oDOEAFUEEfficiency (56-286) >Modulating Burner with up to 10:1 Turndown** Direct Spark Ignition Low NOx Operation >ASMEStainless Steel Heat Exchanger 30 PSI ASME ReliefVaIve >Top and bottom water connections (MNPT)** >Vertical & Horizontal Direct Vent PVC, CPVC, Polypropylene or SSVenting upto 100feet >SMARTSYSTEMControl >Condensate Trap >Other Features Automatic Reset High Limit Adjustable High Limit w/Manual Reset Boiler Circulating Pump Zero Clearancesto Combustible Materials 15-Year Limited Warranty (SeeWarranty for Details) 5-Year Limited PartsWarranty OPTIONAL EQUIPMENT D CON-x-us® Remote ConnectivityD Modbus CommunicationD BACnet MSTPD Flow SwitchD Low-Water Cutoffw/Manua\ Reset & TestD Alarm BellD Concentric Vent KitD Condensate Neutralization Kit0 BMS Gatewayto LONor BACnet IPD Multi-Temperature Loop ControlD Sidewall VentTerminationD Wireless Outdoor SensorD LP GasConversion Kit **Not included on WHN400 -it-Lochinvar' HIGH EFFICIENCY BOILERS & WATER HEATERS Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 p, 615.889.8900 If, 615.547.1000 11 Cl ImC Loc~invar.com """""*'""'"'"*'"'""" ~ USA~,.~;,; 6/17-Printed in U.S.A. 08/10/18