HomeMy WebLinkAboutB18-0254_approved plans_1530648355.pdf07/03/18
07/03/18
DENNIS SCALISE
SCALISE
Quote #: 3TCFA7Z
A Proposal for Window and Door Products prepared for:
Job Site:
80033
Shipping Address:
JORDANS BUILDING CENTER-NEW
5000 WARD RD
WHEAT RIDGE, CO 80033-2018
LEE DRENNEN
JORDANS BUILDING CENTER-NEW
5000 WARD RD
WHEAT RIDGE, CO 80033-2018
Phone: (303) 421-1484
Fax: (303) 421-1823
Email: ldrennen@jordanslumber.com
This report was generated on 6/5/2018 6:54:02 PM
using the Marvin Order Management System,
version 0002.20.00 (Current). Price in USD. Unit
availability and price are subject to change. Dealer
terms and conditions may apply.
Project Description:
INTEGRITY WOOD ULTREX ESTIAMTE FOR AROSA DR. UNIT B PHASE II WINDOWS
Featuring products from:
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 2 of 15
UNIT SUMMARY
The following is a schedule of the windows and doors for this project. For additional unit details, please see Line Item
Quotes.
Additional charges, tax or Terms and Conditions may apply. Detail pricing is per unit.
NUMBER OF LINES: 19 TOTAL UNIT QTY: 34
LINE MARK UNIT BRAND ITEM QTY
1 UPPER WINDOWS SEE
TEMPLATE
Marvin Clad Polygon Direct Glaze
RO 84" X 24"
Entered as
RO 84" X 24"
8
2 LIVING ROOM LEVEL 1 Integrity Wood-Ultrex Rectangle
RO 13 7/8" X 57 1/4"
Entered as
RO 13 7/8" X 57 1/4"
1
3 1ST.LEVEL LIVING
ROOM
Marvin Clad Marvin Assembly
RO 74 1/4" X 16 1/4"
Entered as
RO 74 1/4" X 16 1/4"
1
4 LOWER LEVEL
MASTER BEDROOM
Integrity Wood-Ultrex Casement
RO 28 3/4" X 41 1/4"
Entered as
RO 28 3/4" X 41 1/4"
1
5 LOWER LEVEL
MASTER BEDROOM
Integrity Wood-Ultrex Casement
RO 30 1/4" X 41 1/4"
Entered as
RO 30 1/4" X 41 1/4"
1
6 LOWER LEVEL
MASTER BEDROOM
Integrity Wood-Ultrex Casement
RO 28 3/4" X 41 1/4"
Entered as
RO 28 3/4" X 41 1/4"
1
7 LOWER LEVEL
MASTER BEDROOM
Integrity Wood-Ultrex Casement
RO 30 1/4" X 45"
Entered as
RO 30 1/4" X 45"
1
8 MAIN OFFICE
BEDROOM
Integrity Wood-Ultrex Integrity Assembly
RO 65 3/4" X 40"
Entered as
RO 65 3/4" X 40"
1
9 MAIN LEVEL BEDROOM Integrity Wood-Ultrex Casement
RO 26 1/2" X 57 1/2"
Entered as
RO 26 1/2" X 57 1/2"
1
10 MAIN LEVEL MASTER
BEDROOM
Integrity Wood-Ultrex Casement
RO 20 1/2" X 44 1/2"
Entered as
RO 20 1/2" X 44 1/2"
1
11 UPPER LEVEL BED #1 Integrity Wood-Ultrex Casement
RO 31" X 58 3/4"
Entered as
RO 31" X 58 3/4"
1
12 DINING ROOM MAIN
LEVEL
Integrity Wood-Ultrex Casement Picture
RO 53 1/2" X 60 1/2"
Entered as
RO 53 1/2" X 60 1/2"
1
13 DINING ROOM MAIN
LEVEL
Integrity Wood-Ultrex Casement
RO 17" X 60 1/2"
Entered as
CN 17 X RO 60 1/2"
1
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 3 of 15
14 ROOF HICKORY EAST
BATH
Marvin Clad Ultimate Awning
RO 20 3/4" X 24"
Entered as
RO 20 3/4" X 24"
2
15 ROOF CYPRESS LIVING
WEST
Marvin Clad Ultimate Awning
RO 20 3/4" X 24"
Entered as
RO 20 3/4" X 24"
2
16 ROOF CYPRESS EAST
UPPER BED
Marvin Clad Ultimate Awning
RO 20 3/4" X 24"
Entered as
RO 20 3/4" X 24"
2
17 AWNING ADAPTER Marvin Parts: 05570447 POLE CRANK ADAPTER 6
18 AWNING POLE Marvin Parts: 01590411 POLE CRANK-96", MILL FINISH 1
19 DELIVERY FEE Non-Marvin Other
DELIVERY FEE
1
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 4 of 15
LINE ITEM QUOTES
The following is a schedule of the windows and doors for this project. For additional unit details, please see Line Item
Quotes. Additional charges, tax or Terms and Conditions may apply. Detail pricing is per unit.
Line #1
Qty: 8
Mark Unit: UPPER WINDOWS SEE TEMPLATE
Entered As: RO
FS 83" X 23 31/64"
RO 84" X 24"
Egress Information
No Egress Information available.
Performance Information
Product Performance Information is currently
unavailable in the OMS for this product and
glazing option. To request product performance
information not in the OMS, contact your Marvin
representative or submit an Assistance Request.
Performance Grade
No Performance Grade Information available.
Bronze Clad Exterior
Bare Pine Interior
Clad Polygon Direct Glaze
P4-3
Rough Opening 84" X 24"
S1 Rough Opening 22 1/2"
Frame Size 83" X 23 31/64"
S1 Frame Size 22"
IG - 1 Lite
Tempered Low E3
Capillary Tube
Stainless Perimeter Bar
6 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #2
Qty: 1
Mark Unit: LIVING ROOM LEVEL 1
Entered As: RO
FS 12 7/8" X 56 3/4"
RO 13 7/8" X 57 1/4"
Egress Information
No Egress Information available.
Performance Information
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.24
Visible Light Transmittance: 0.54
Condensation Resistance: 56
CPD Number: MAR-N-303-02087-00001
ENERGY STAR: NC, SC, S
Performance Grade
Licensee #876
AAMA/WDMA/CSA/101/ I.S.2/A440-08
Bronze Exterior
Bare Pine Interior
Integrity Rectangle
Wood-Ultrex
Rough Opening 13 7/8" X 57 1/4"
IG - 1 Lite
Tempered Low E3
Capillary Tube
Additional Mull Info: Stand Alone
4 9/16" Jambs
Nailing Fin CM/AWN Frame
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 5 of 15
CW-PG50 2134X2134 mm (60X109 in)
CW-PG50 DP +50/-50
FL10172
Line #3
Qty: 1
Mark Unit: 1ST.LEVEL LIVING ROOM
Entered As: RO
FS 73 1/4" X 15 3/4"
RO 74 1/4" X 16 1/4"
Egress Information A1, A2
No Egress Information available.
Performance Information A1
U-Factor: 0.31
Solar Heat Gain Coefficient: 0.22
Visible Light Transmittance: 0.51
Condensation Resistance: 55
CPD Number: MAR-N-344-06609-00001
ENERGY STAR: S
Performance Information A2
U-Factor: 0.32
Solar Heat Gain Coefficient: 0.19
Visible Light Transmittance: 0.44
Condensation Resistance: 54
CPD Number: MAR-N-343-04998-00001
ENERGY STAR: S
Performance Grade A1
Licensee #917
AAMA/WDMA/CSA/101/ I.S.2/A440-08
CW-PG50 1626X2442 mm (64X96.2 in)
CW-PG50 DP +50/-50
FL10325
Performance Grade A2
Licensee #921
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 1016X1197 mm (40X47.2 in)
LC-PG50 DP +50/-50
FL10323
Performance Grade Mull
Licensee #917
AAMA 450-10
1524X2111 mm (60X83.12 in)
50
FL13150
Bronze Clad Exterior
Bare Pine Interior
2W1H - Rectangle Assembly
Assembly Rough Opening
74 1/4" X 16 1/4"
Unit: A1
Clad Ultimate Awning Picture
Basic Frame 49 1/4" X 15 3/4"
Rough Opening 50 1/4" X 16 1/4"
Bronze Clad Sash Exterior
Bare Pine Sash Interior
IG - 3/4" - 1 Lite
Tempered Low E3
Capillary Tube
Stainless Perimeter Bar
Ogee Interior Glazing Profile
Standard Bottom Rail
Black Weather Strip
Solid Wood Covers
Unit: A2
Clad Ultimate Awning - Roto Operating
CN 24 X Basic Frame 15 3/4"
Rough Opening 25" X 16 1/4"
Frame Size 24" X 15 3/4"
Bronze Clad Sash Exterior
Bare Pine Sash Interior
IG - 3/4" - 1 Lite
Tempered Low E3
Capillary Tube
Stainless Perimeter Bar
Ogee Interior Glazing Profile
Standard Bottom Rail
Black Weather Strip
Oil Rubbed Bronze Folding Handle
Oil Rubbed Bronze Multi - Point Lock
Interior Wood Screen
Charcoal Hi-Transparency Fbrgls Mesh
Bare Pine
Ogee Interior Screen Profile
Factory Mull Charge
4 9/16" Jambs
Nailing Fin
***Note: This configuration is certified to AAMA 450. Mull certification ratings may vary from individual
unit certification ratings.
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #4
Qty: 1
Mark Unit: LOWER LEVEL MASTER BEDROOM
Bronze Exterior
Bare Pine Interior
Integrity Casement - Stationary
Wood-Ultrex
Rough Opening 28 3/4" X 41 1/4"
IG - 1 Lite
Tempered Low E3
Capillary Tube
4 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 6 of 15
Entered As: RO
FS 27 3/4" X 40 3/4"
RO 28 3/4" X 41 1/4"
Egress Information
No Egress Information available.
Performance Information
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.46
Condensation Resistance: 56
CPD Number: MAR-N-250-00723-00001
ENERGY STAR: NC, SC, S
Performance Grade
Licensee #898
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 711X1807 mm (29X71.5 in)
LC-PG50 DP +50/-50
FL9684
Line #5
Qty: 1
Mark Unit: LOWER LEVEL MASTER BEDROOM
Entered As: RO
FS 29 1/4" X 40 3/4"
RO 30 1/4" X 41 1/4"
Egress Information
Width: 20 31/64" Height: 36 11/32"
Net Clear Opening: 5.17 SqFt
Performance Information
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.46
Bronze Exterior
Bare Pine Interior
Integrity Casement - Right Hand
Wood-Ultrex
Rough Opening 30 1/4" X 41 1/4"
IG - 1 Lite
Tempered Low E3
Capillary Tube
Oil Rubbed Bronze Folding Handle
Interior Aluminum Screen
Charcoal Fiberglass Mesh
BA Wood Veneer Surround
4 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 7 of 15
Condensation Resistance: 56
CPD Number: MAR-N-250-00723-00001
ENERGY STAR: NC, SC, S
Performance Grade
Licensee #898
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 737X1807 mm (30X71.5 in)
LC-PG50 DP +50/-50
FL9684
Line #6
Qty: 1
Mark Unit: LOWER LEVEL MASTER BEDROOM
Entered As: RO
FS 27 3/4" X 40 3/4"
RO 28 3/4" X 41 1/4"
Egress Information
No Egress Information available.
Performance Information
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.46
Condensation Resistance: 56
CPD Number: MAR-N-250-00723-00001
ENERGY STAR: NC, SC, S
Performance Grade
Licensee #898
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 711X1807 mm (29X71.5 in)
LC-PG50 DP +50/-50
FL9684
Bronze Exterior
Bare Pine Interior
Integrity Casement - Stationary
Wood-Ultrex
Rough Opening 28 3/4" X 41 1/4"
IG - 1 Lite
Tempered Low E3
Capillary Tube
4 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #7
Qty: 1
Mark Unit: LOWER LEVEL MASTER BEDROOM
Bronze Exterior
Bare Pine Interior
Integrity Casement - Right Hand
Wood-Ultrex
Rough Opening 30 1/4" X 45"
IG - 1 Lite
Tempered Low E3
Capillary Tube
Oil Rubbed Bronze Folding Handle
Interior Aluminum Screen
Charcoal Fiberglass Mesh
BA Wood Veneer Surround
4 9/16" Jambs
Nailing Fin
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 8 of 15
Entered As: RO
FS 29 1/4" X 44 1/2"
RO 30 1/4" X 45"
Egress Information
Width: 20 31/64" Height: 40 3/32"
Net Clear Opening: 5.71 SqFt
Performance Information
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.46
Condensation Resistance: 56
CPD Number: MAR-N-250-00723-00001
ENERGY STAR: NC, SC, S
Performance Grade
Licensee #898
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 737X1807 mm (30X71.5 in)
LC-PG50 DP +50/-50
FL9684
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #8
Qty: 1
Mark Unit: MAIN OFFICE BEDROOM
Entered As: RO
FS 64 3/4" X 39 1/2"
RO 65 3/4" X 40"
Egress Information A1, A2
Width: 23 39/64" Height: 35 3/32"
Net Clear Opening: 5.76 SqFt
Performance Information A1, A2
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.46
Condensation Resistance: 56
CPD Number: MAR-N-250-00723-00001
ENERGY STAR: NC, SC, S
Performance Grade A1, A2
Licensee #898
AAMA/WDMA/CSA/101/ I.S.2/A440-08
Bronze Exterior
Bare Pine Interior
2W1H - Rectangle Assembly
Assembly Rough Opening
65 3/4" X 40"
Unit: A1
Integrity Casement - Left Hand
Wood-Ultrex
Basic Frame 32 3/8" X 39 1/2"
Rough Opening 33 3/8" X 40"
IG - 1 Lite
Tempered Low E3
Capillary Tube
Oil Rubbed Bronze Folding Handle
Interior Aluminum Screen
Charcoal Fiberglass Mesh
BA Wood Veneer Surround
Unit: A2
Integrity Casement - Right Hand
Wood-Ultrex
Basic Frame 32 3/8" X 39 1/2"
Rough Opening 33 3/8" X 40"
IG - 1 Lite
Tempered Low E3
Capillary Tube
Oil Rubbed Bronze Folding Handle
Interior Aluminum Screen
Charcoal Fiberglass Mesh
BA Wood Veneer Surround
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 9 of 15
LC-PG50 914X994 mm (37X39.5 in)
LC-PG50 DP +50/-50
FL9684
Performance Grade Mull
Licensee #898
AAMA 450-10
LC-PG50 2844X1829 mm (56X72 in)
LC-PG50 DP 50
FL14133
Performance Grade Overall Assembly
LC-PG50 LC-PG50 DP
4 9/16" Jambs
Nailing Fin w/ Certification Brackets
***Note: This configuration is certified to AAMA 450.
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #9
Qty: 1
Mark Unit: MAIN LEVEL BEDROOM
Entered As: RO
FS 25 1/2" X 57"
RO 26 1/2" X 57 1/2"
Egress Information
Width: 16 47/64" Height: 52 19/32"
Net Clear Opening: 6.12 SqFt
Performance Information
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.46
Condensation Resistance: 56
CPD Number: MAR-N-250-00723-00001
ENERGY STAR: NC, SC, S
Performance Grade
Licensee #898
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 711X1807 mm (29X71.5 in)
LC-PG50 DP +50/-50
FL9684
Bronze Exterior
Bare Pine Interior
Integrity Casement - Right Hand
Wood-Ultrex
Rough Opening 26 1/2" X 57 1/2"
IG - 1 Lite
Tempered Low E3
Capillary Tube
Oil Rubbed Bronze Folding Handle
Interior Aluminum Screen
Charcoal Fiberglass Mesh
BA Wood Veneer Surround
4 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #10
Qty: 1
Mark Unit: MAIN LEVEL MASTER BEDROOM
Bronze Exterior
Bare Pine Interior
Integrity Casement - Right Hand
Wood-Ultrex
Rough Opening 20 1/2" X 44 1/2"
IG - 1 Lite
Tempered Low E3
Capillary Tube
Oil Rubbed Bronze Folding Handle
Interior Aluminum Screen
Charcoal Fiberglass Mesh
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 10 of 15
Entered As: RO
FS 19 1/2" X 44"
RO 20 1/2" X 44 1/2"
Egress Information
Width: 10 47/64" Height: 39 19/32"
Net Clear Opening: 2.95 SqFt
Performance Information
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.46
Condensation Resistance: 56
CPD Number: MAR-N-250-00723-00001
ENERGY STAR: NC, SC, S
Performance Grade
Licensee #898
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 610X1807 mm (25X71.5 in)
LC-PG50 DP +50/-50
FL9684
BA Wood Veneer Surround
4 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #11
Qty: 1
Mark Unit: UPPER LEVEL BED #1
Entered As: RO
FS 30" X 58 1/4"
RO 31" X 58 3/4"
Egress Information
Width: 21 15/64" Height: 53 27/32"
Net Clear Opening: 7.94 SqFt
Performance Information
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.2
Bronze Exterior
Bare Pine Interior
Integrity Casement - Right Hand
Wood-Ultrex
Rough Opening 31" X 58 3/4"
IG - 1 Lite
Tempered Low E3
Capillary Tube
Oil Rubbed Bronze Folding Handle
Interior Aluminum Screen
Charcoal Fiberglass Mesh
BA Wood Veneer Surround
4 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 11 of 15
Visible Light Transmittance: 0.46
Condensation Resistance: 56
CPD Number: MAR-N-250-00723-00001
ENERGY STAR: NC, SC, S
Performance Grade
Licensee #898
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 737X1807 mm (30X71.5 in)
LC-PG50 DP +50/-50
FL9684
Line #12
Qty: 1
Mark Unit: DINING ROOM MAIN LEVEL
Entered As: RO
FS 52 1/2" X 60"
RO 53 1/2" X 60 1/2"
Egress Information
No Egress Information available.
Performance Information
U-Factor: 0.31
Solar Heat Gain Coefficient: 0.23
Visible Light Transmittance: 0.52
Condensation Resistance: 53
CPD Number: MAR-N-252-01081-00001
ENERGY STAR: S
Performance Grade
Licensee #900
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 1422X1807 mm (57X71.7 in)
LC-PG50 DP +50/-50
FL9690
Bronze Exterior
Bare Pine Interior
Integrity Casement Picture
Wood-Ultrex
Rough Opening 53 1/2" X 60 1/2"
IG - 1 Lite
Tempered Low E3
Capillary Tube
4 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #13
Qty: 1
Mark Unit: DINING ROOM MAIN LEVEL
Bronze Exterior
Bare Pine Interior
Integrity Casement - Right Hand
Wood-Ultrex
CN 17 X Rough Opening 60 1/2"
Rough Opening 17" X 60 1/2"
IG - 1 Lite
Tempered Low E3
Capillary Tube
Oil Rubbed Bronze Folding Handle
Interior Aluminum Screen
Charcoal Fiberglass Mesh
BA Wood Veneer Surround
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 12 of 15
Entered As: CN x RO
FS 16" X 60"
RO 17" X 60 1/2"
Egress Information
Width: 7 15/64" Height: 55 19/32"
Net Clear Opening: 2.80 SqFt
Performance Information
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.46
Condensation Resistance: 56
CPD Number: MAR-N-250-00723-00001
ENERGY STAR: NC, SC, S
Performance Grade
Licensee #898
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 610X1807 mm (25X71.5 in)
LC-PG50 DP +50/-50
FL9684
4 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #14
Qty: 2
Mark Unit: ROOF HICKORY EAST BATH
Entered As: RO
FS 19 3/4" X 23 1/2"
RO 20 3/4" X 24"
Egress Information
No Egress Information available.
Performance Information
U-Factor: 0.32
Solar Heat Gain Coefficient: 0.19
Visible Light Transmittance: 0.44
Condensation Resistance: 54
Bronze Clad Exterior
Bare Pine Interior
Clad Ultimate Awning - Roto Operating
Rough Opening 20 3/4" X 24"
Frame Size 19 3/4" X 23 1/2"
Bronze Clad Sash Exterior
Bare Pine Sash Interior
IG - 3/4" - 1 Lite
Tempered Low E3
Capillary Tube
Stainless Perimeter Bar
Ogee Interior Glazing Profile
Standard Bottom Rail
Black Weather Strip
Oil Rubbed Bronze Folding Handle
Oil Rubbed Bronze Multi - Point Lock
Interior Wood Screen
Charcoal Hi-Transparency Fbrgls Mesh
Bare Pine
Ogee Interior Screen Profile
6 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 13 of 15
CPD Number: MAR-N-343-04998-00001
ENERGY STAR: S
Performance Grade
Licensee #921
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 1016X1197 mm (40X47.2 in)
LC-PG50 DP +50/-50
FL10323
Line #15
Qty: 2
Mark Unit: ROOF CYPRESS LIVING WEST
Entered As: RO
FS 19 3/4" X 23 1/2"
RO 20 3/4" X 24"
Egress Information
No Egress Information available.
Performance Information
U-Factor: 0.32
Solar Heat Gain Coefficient: 0.19
Visible Light Transmittance: 0.44
Condensation Resistance: 54
CPD Number: MAR-N-343-04998-00001
ENERGY STAR: S
Performance Grade
Licensee #921
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 1016X1197 mm (40X47.2 in)
LC-PG50 DP +50/-50
FL10323
Bronze Clad Exterior
Bare Pine Interior
Clad Ultimate Awning - Roto Operating
Rough Opening 20 3/4" X 24"
Frame Size 19 3/4" X 23 1/2"
Bronze Clad Sash Exterior
Bare Pine Sash Interior
IG - 3/4" - 1 Lite
Tempered Low E3
Capillary Tube
Stainless Perimeter Bar
Ogee Interior Glazing Profile
Standard Bottom Rail
Black Weather Strip
Oil Rubbed Bronze Folding Handle
Oil Rubbed Bronze Multi - Point Lock
Interior Wood Screen
Charcoal Hi-Transparency Fbrgls Mesh
Bare Pine
Ogee Interior Screen Profile
6 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #16
Qty: 2
Mark Unit: ROOF CYPRESS EAST UPPER BED
Bronze Clad Exterior
Bare Pine Interior
Clad Ultimate Awning - Roto Operating
Rough Opening 20 3/4" X 24"
Frame Size 19 3/4" X 23 1/2"
Bronze Clad Sash Exterior
Bare Pine Sash Interior
IG - 3/4" - 1 Lite
Tempered Low E3
Capillary Tube
Stainless Perimeter Bar
Ogee Interior Glazing Profile
Standard Bottom Rail
Black Weather Strip
Oil Rubbed Bronze Folding Handle
Oil Rubbed Bronze Multi - Point Lock
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 14 of 15
Entered As: RO
FS 19 3/4" X 23 1/2"
RO 20 3/4" X 24"
Egress Information
No Egress Information available.
Performance Information
U-Factor: 0.32
Solar Heat Gain Coefficient: 0.19
Visible Light Transmittance: 0.44
Condensation Resistance: 54
CPD Number: MAR-N-343-04998-00001
ENERGY STAR: S
Performance Grade
Licensee #921
AAMA/WDMA/CSA/101/ I.S.2/A440-08
LC-PG50 1016X1197 mm (40X47.2 in)
LC-PG50 DP +50/-50
FL10323
Interior Wood Screen
Charcoal Hi-Transparency Fbrgls Mesh
Bare Pine
Ogee Interior Screen Profile
6 9/16" Jambs
Nailing Fin
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #17
Qty: 6
Mark Unit: AWNING ADAPTER
No Image Available Marvin Parts
05570447 POLE CRANK ADAPTER
Line #18
Qty: 1 Mark Unit: AWNING POLE
No Image Available Marvin Parts
01590411 POLE CRANK-96", MILL FINISH
Line #19
Qty: 1 Mark Unit: DELIVERY FEE
Other DELIVERY FEE
07/03/18
OMS Ver. 0002.20.00 (Current)
Product availability and pricing subject to change.
DENNIS SCALISE
SCALISE
Quote Number: 3TCFA7Z
Architectural Project Number:
OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 15 of 15
Product and Performance Information
NFRC energy ratings and values may vary depending on the exact configuration of glass thickness used on the unit. This
data may change over time due to ongoing product changes or updated test results or requirements.
The National Fenestration Rating Council (NFRC) has developed and operates a uniform national rating system for the
energy performance of fenestration products, including windows and doors. For additional information regarding this
rating system, see www.nfrc.org/WindowRatings.
NFRC energy values and ratings may change over time due to ongoing product changes, updated test results or
requirements.
Review the map below to determine if your units meet ENERGY STAR for your location.
07/03/18