Loading...
HomeMy WebLinkAboutB18-0254_approved plans_1530648355.pdf07/03/18 07/03/18 DENNIS SCALISE SCALISE Quote #: 3TCFA7Z A Proposal for Window and Door Products prepared for: Job Site: 80033 Shipping Address: JORDANS BUILDING CENTER-NEW 5000 WARD RD WHEAT RIDGE, CO 80033-2018 LEE DRENNEN JORDANS BUILDING CENTER-NEW 5000 WARD RD WHEAT RIDGE, CO 80033-2018 Phone: (303) 421-1484 Fax: (303) 421-1823 Email: ldrennen@jordanslumber.com This report was generated on 6/5/2018 6:54:02 PM using the Marvin Order Management System, version 0002.20.00 (Current). Price in USD. Unit availability and price are subject to change. Dealer terms and conditions may apply. Project Description: INTEGRITY WOOD ULTREX ESTIAMTE FOR AROSA DR. UNIT B PHASE II WINDOWS Featuring products from: 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 2 of 15 UNIT SUMMARY The following is a schedule of the windows and doors for this project. For additional unit details, please see Line Item Quotes. Additional charges, tax or Terms and Conditions may apply. Detail pricing is per unit. NUMBER OF LINES: 19 TOTAL UNIT QTY: 34 LINE MARK UNIT BRAND ITEM QTY 1 UPPER WINDOWS SEE TEMPLATE Marvin Clad Polygon Direct Glaze RO 84" X 24" Entered as RO 84" X 24" 8 2 LIVING ROOM LEVEL 1 Integrity Wood-Ultrex Rectangle RO 13 7/8" X 57 1/4" Entered as RO 13 7/8" X 57 1/4" 1 3 1ST.LEVEL LIVING ROOM Marvin Clad Marvin Assembly RO 74 1/4" X 16 1/4" Entered as RO 74 1/4" X 16 1/4" 1 4 LOWER LEVEL MASTER BEDROOM Integrity Wood-Ultrex Casement RO 28 3/4" X 41 1/4" Entered as RO 28 3/4" X 41 1/4" 1 5 LOWER LEVEL MASTER BEDROOM Integrity Wood-Ultrex Casement RO 30 1/4" X 41 1/4" Entered as RO 30 1/4" X 41 1/4" 1 6 LOWER LEVEL MASTER BEDROOM Integrity Wood-Ultrex Casement RO 28 3/4" X 41 1/4" Entered as RO 28 3/4" X 41 1/4" 1 7 LOWER LEVEL MASTER BEDROOM Integrity Wood-Ultrex Casement RO 30 1/4" X 45" Entered as RO 30 1/4" X 45" 1 8 MAIN OFFICE BEDROOM Integrity Wood-Ultrex Integrity Assembly RO 65 3/4" X 40" Entered as RO 65 3/4" X 40" 1 9 MAIN LEVEL BEDROOM Integrity Wood-Ultrex Casement RO 26 1/2" X 57 1/2" Entered as RO 26 1/2" X 57 1/2" 1 10 MAIN LEVEL MASTER BEDROOM Integrity Wood-Ultrex Casement RO 20 1/2" X 44 1/2" Entered as RO 20 1/2" X 44 1/2" 1 11 UPPER LEVEL BED #1 Integrity Wood-Ultrex Casement RO 31" X 58 3/4" Entered as RO 31" X 58 3/4" 1 12 DINING ROOM MAIN LEVEL Integrity Wood-Ultrex Casement Picture RO 53 1/2" X 60 1/2" Entered as RO 53 1/2" X 60 1/2" 1 13 DINING ROOM MAIN LEVEL Integrity Wood-Ultrex Casement RO 17" X 60 1/2" Entered as CN 17 X RO 60 1/2" 1 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 3 of 15 14 ROOF HICKORY EAST BATH Marvin Clad Ultimate Awning RO 20 3/4" X 24" Entered as RO 20 3/4" X 24" 2 15 ROOF CYPRESS LIVING WEST Marvin Clad Ultimate Awning RO 20 3/4" X 24" Entered as RO 20 3/4" X 24" 2 16 ROOF CYPRESS EAST UPPER BED Marvin Clad Ultimate Awning RO 20 3/4" X 24" Entered as RO 20 3/4" X 24" 2 17 AWNING ADAPTER Marvin Parts: 05570447 POLE CRANK ADAPTER 6 18 AWNING POLE Marvin Parts: 01590411 POLE CRANK-96", MILL FINISH 1 19 DELIVERY FEE Non-Marvin Other DELIVERY FEE 1 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 4 of 15 LINE ITEM QUOTES The following is a schedule of the windows and doors for this project. For additional unit details, please see Line Item Quotes. Additional charges, tax or Terms and Conditions may apply. Detail pricing is per unit. Line #1 Qty: 8 Mark Unit: UPPER WINDOWS SEE TEMPLATE Entered As: RO FS 83" X 23 31/64" RO 84" X 24" Egress Information No Egress Information available. Performance Information Product Performance Information is currently unavailable in the OMS for this product and glazing option. To request product performance information not in the OMS, contact your Marvin representative or submit an Assistance Request. Performance Grade No Performance Grade Information available. Bronze Clad Exterior Bare Pine Interior Clad Polygon Direct Glaze P4-3 Rough Opening 84" X 24" S1 Rough Opening 22 1/2" Frame Size 83" X 23 31/64" S1 Frame Size 22" IG - 1 Lite Tempered Low E3 Capillary Tube Stainless Perimeter Bar 6 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #2 Qty: 1 Mark Unit: LIVING ROOM LEVEL 1 Entered As: RO FS 12 7/8" X 56 3/4" RO 13 7/8" X 57 1/4" Egress Information No Egress Information available. Performance Information U-Factor: 0.3 Solar Heat Gain Coefficient: 0.24 Visible Light Transmittance: 0.54 Condensation Resistance: 56 CPD Number: MAR-N-303-02087-00001 ENERGY STAR: NC, SC, S Performance Grade Licensee #876 AAMA/WDMA/CSA/101/ I.S.2/A440-08 Bronze Exterior Bare Pine Interior Integrity Rectangle Wood-Ultrex Rough Opening 13 7/8" X 57 1/4" IG - 1 Lite Tempered Low E3 Capillary Tube Additional Mull Info: Stand Alone 4 9/16" Jambs Nailing Fin CM/AWN Frame ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 5 of 15 CW-PG50 2134X2134 mm (60X109 in) CW-PG50 DP +50/-50 FL10172 Line #3 Qty: 1 Mark Unit: 1ST.LEVEL LIVING ROOM Entered As: RO FS 73 1/4" X 15 3/4" RO 74 1/4" X 16 1/4" Egress Information A1, A2 No Egress Information available. Performance Information A1 U-Factor: 0.31 Solar Heat Gain Coefficient: 0.22 Visible Light Transmittance: 0.51 Condensation Resistance: 55 CPD Number: MAR-N-344-06609-00001 ENERGY STAR: S Performance Information A2 U-Factor: 0.32 Solar Heat Gain Coefficient: 0.19 Visible Light Transmittance: 0.44 Condensation Resistance: 54 CPD Number: MAR-N-343-04998-00001 ENERGY STAR: S Performance Grade A1 Licensee #917 AAMA/WDMA/CSA/101/ I.S.2/A440-08 CW-PG50 1626X2442 mm (64X96.2 in) CW-PG50 DP +50/-50 FL10325 Performance Grade A2 Licensee #921 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 1016X1197 mm (40X47.2 in) LC-PG50 DP +50/-50 FL10323 Performance Grade Mull Licensee #917 AAMA 450-10 1524X2111 mm (60X83.12 in) 50 FL13150 Bronze Clad Exterior Bare Pine Interior 2W1H - Rectangle Assembly Assembly Rough Opening 74 1/4" X 16 1/4" Unit: A1 Clad Ultimate Awning Picture Basic Frame 49 1/4" X 15 3/4" Rough Opening 50 1/4" X 16 1/4" Bronze Clad Sash Exterior Bare Pine Sash Interior IG - 3/4" - 1 Lite Tempered Low E3 Capillary Tube Stainless Perimeter Bar Ogee Interior Glazing Profile Standard Bottom Rail Black Weather Strip Solid Wood Covers Unit: A2 Clad Ultimate Awning - Roto Operating CN 24 X Basic Frame 15 3/4" Rough Opening 25" X 16 1/4" Frame Size 24" X 15 3/4" Bronze Clad Sash Exterior Bare Pine Sash Interior IG - 3/4" - 1 Lite Tempered Low E3 Capillary Tube Stainless Perimeter Bar Ogee Interior Glazing Profile Standard Bottom Rail Black Weather Strip Oil Rubbed Bronze Folding Handle Oil Rubbed Bronze Multi - Point Lock Interior Wood Screen Charcoal Hi-Transparency Fbrgls Mesh Bare Pine Ogee Interior Screen Profile Factory Mull Charge 4 9/16" Jambs Nailing Fin ***Note: This configuration is certified to AAMA 450. Mull certification ratings may vary from individual unit certification ratings. ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #4 Qty: 1 Mark Unit: LOWER LEVEL MASTER BEDROOM Bronze Exterior Bare Pine Interior Integrity Casement - Stationary Wood-Ultrex Rough Opening 28 3/4" X 41 1/4" IG - 1 Lite Tempered Low E3 Capillary Tube 4 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 6 of 15 Entered As: RO FS 27 3/4" X 40 3/4" RO 28 3/4" X 41 1/4" Egress Information No Egress Information available. Performance Information U-Factor: 0.3 Solar Heat Gain Coefficient: 0.2 Visible Light Transmittance: 0.46 Condensation Resistance: 56 CPD Number: MAR-N-250-00723-00001 ENERGY STAR: NC, SC, S Performance Grade Licensee #898 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 711X1807 mm (29X71.5 in) LC-PG50 DP +50/-50 FL9684 Line #5 Qty: 1 Mark Unit: LOWER LEVEL MASTER BEDROOM Entered As: RO FS 29 1/4" X 40 3/4" RO 30 1/4" X 41 1/4" Egress Information Width: 20 31/64" Height: 36 11/32" Net Clear Opening: 5.17 SqFt Performance Information U-Factor: 0.3 Solar Heat Gain Coefficient: 0.2 Visible Light Transmittance: 0.46 Bronze Exterior Bare Pine Interior Integrity Casement - Right Hand Wood-Ultrex Rough Opening 30 1/4" X 41 1/4" IG - 1 Lite Tempered Low E3 Capillary Tube Oil Rubbed Bronze Folding Handle Interior Aluminum Screen Charcoal Fiberglass Mesh BA Wood Veneer Surround 4 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 7 of 15 Condensation Resistance: 56 CPD Number: MAR-N-250-00723-00001 ENERGY STAR: NC, SC, S Performance Grade Licensee #898 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 737X1807 mm (30X71.5 in) LC-PG50 DP +50/-50 FL9684 Line #6 Qty: 1 Mark Unit: LOWER LEVEL MASTER BEDROOM Entered As: RO FS 27 3/4" X 40 3/4" RO 28 3/4" X 41 1/4" Egress Information No Egress Information available. Performance Information U-Factor: 0.3 Solar Heat Gain Coefficient: 0.2 Visible Light Transmittance: 0.46 Condensation Resistance: 56 CPD Number: MAR-N-250-00723-00001 ENERGY STAR: NC, SC, S Performance Grade Licensee #898 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 711X1807 mm (29X71.5 in) LC-PG50 DP +50/-50 FL9684 Bronze Exterior Bare Pine Interior Integrity Casement - Stationary Wood-Ultrex Rough Opening 28 3/4" X 41 1/4" IG - 1 Lite Tempered Low E3 Capillary Tube 4 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #7 Qty: 1 Mark Unit: LOWER LEVEL MASTER BEDROOM Bronze Exterior Bare Pine Interior Integrity Casement - Right Hand Wood-Ultrex Rough Opening 30 1/4" X 45" IG - 1 Lite Tempered Low E3 Capillary Tube Oil Rubbed Bronze Folding Handle Interior Aluminum Screen Charcoal Fiberglass Mesh BA Wood Veneer Surround 4 9/16" Jambs Nailing Fin 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 8 of 15 Entered As: RO FS 29 1/4" X 44 1/2" RO 30 1/4" X 45" Egress Information Width: 20 31/64" Height: 40 3/32" Net Clear Opening: 5.71 SqFt Performance Information U-Factor: 0.3 Solar Heat Gain Coefficient: 0.2 Visible Light Transmittance: 0.46 Condensation Resistance: 56 CPD Number: MAR-N-250-00723-00001 ENERGY STAR: NC, SC, S Performance Grade Licensee #898 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 737X1807 mm (30X71.5 in) LC-PG50 DP +50/-50 FL9684 ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #8 Qty: 1 Mark Unit: MAIN OFFICE BEDROOM Entered As: RO FS 64 3/4" X 39 1/2" RO 65 3/4" X 40" Egress Information A1, A2 Width: 23 39/64" Height: 35 3/32" Net Clear Opening: 5.76 SqFt Performance Information A1, A2 U-Factor: 0.3 Solar Heat Gain Coefficient: 0.2 Visible Light Transmittance: 0.46 Condensation Resistance: 56 CPD Number: MAR-N-250-00723-00001 ENERGY STAR: NC, SC, S Performance Grade A1, A2 Licensee #898 AAMA/WDMA/CSA/101/ I.S.2/A440-08 Bronze Exterior Bare Pine Interior 2W1H - Rectangle Assembly Assembly Rough Opening 65 3/4" X 40" Unit: A1 Integrity Casement - Left Hand Wood-Ultrex Basic Frame 32 3/8" X 39 1/2" Rough Opening 33 3/8" X 40" IG - 1 Lite Tempered Low E3 Capillary Tube Oil Rubbed Bronze Folding Handle Interior Aluminum Screen Charcoal Fiberglass Mesh BA Wood Veneer Surround Unit: A2 Integrity Casement - Right Hand Wood-Ultrex Basic Frame 32 3/8" X 39 1/2" Rough Opening 33 3/8" X 40" IG - 1 Lite Tempered Low E3 Capillary Tube Oil Rubbed Bronze Folding Handle Interior Aluminum Screen Charcoal Fiberglass Mesh BA Wood Veneer Surround 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 9 of 15 LC-PG50 914X994 mm (37X39.5 in) LC-PG50 DP +50/-50 FL9684 Performance Grade Mull Licensee #898 AAMA 450-10 LC-PG50 2844X1829 mm (56X72 in) LC-PG50 DP 50 FL14133 Performance Grade Overall Assembly LC-PG50 LC-PG50 DP 4 9/16" Jambs Nailing Fin w/ Certification Brackets ***Note: This configuration is certified to AAMA 450. ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #9 Qty: 1 Mark Unit: MAIN LEVEL BEDROOM Entered As: RO FS 25 1/2" X 57" RO 26 1/2" X 57 1/2" Egress Information Width: 16 47/64" Height: 52 19/32" Net Clear Opening: 6.12 SqFt Performance Information U-Factor: 0.3 Solar Heat Gain Coefficient: 0.2 Visible Light Transmittance: 0.46 Condensation Resistance: 56 CPD Number: MAR-N-250-00723-00001 ENERGY STAR: NC, SC, S Performance Grade Licensee #898 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 711X1807 mm (29X71.5 in) LC-PG50 DP +50/-50 FL9684 Bronze Exterior Bare Pine Interior Integrity Casement - Right Hand Wood-Ultrex Rough Opening 26 1/2" X 57 1/2" IG - 1 Lite Tempered Low E3 Capillary Tube Oil Rubbed Bronze Folding Handle Interior Aluminum Screen Charcoal Fiberglass Mesh BA Wood Veneer Surround 4 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #10 Qty: 1 Mark Unit: MAIN LEVEL MASTER BEDROOM Bronze Exterior Bare Pine Interior Integrity Casement - Right Hand Wood-Ultrex Rough Opening 20 1/2" X 44 1/2" IG - 1 Lite Tempered Low E3 Capillary Tube Oil Rubbed Bronze Folding Handle Interior Aluminum Screen Charcoal Fiberglass Mesh 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 10 of 15 Entered As: RO FS 19 1/2" X 44" RO 20 1/2" X 44 1/2" Egress Information Width: 10 47/64" Height: 39 19/32" Net Clear Opening: 2.95 SqFt Performance Information U-Factor: 0.3 Solar Heat Gain Coefficient: 0.2 Visible Light Transmittance: 0.46 Condensation Resistance: 56 CPD Number: MAR-N-250-00723-00001 ENERGY STAR: NC, SC, S Performance Grade Licensee #898 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 610X1807 mm (25X71.5 in) LC-PG50 DP +50/-50 FL9684 BA Wood Veneer Surround 4 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #11 Qty: 1 Mark Unit: UPPER LEVEL BED #1 Entered As: RO FS 30" X 58 1/4" RO 31" X 58 3/4" Egress Information Width: 21 15/64" Height: 53 27/32" Net Clear Opening: 7.94 SqFt Performance Information U-Factor: 0.3 Solar Heat Gain Coefficient: 0.2 Bronze Exterior Bare Pine Interior Integrity Casement - Right Hand Wood-Ultrex Rough Opening 31" X 58 3/4" IG - 1 Lite Tempered Low E3 Capillary Tube Oil Rubbed Bronze Folding Handle Interior Aluminum Screen Charcoal Fiberglass Mesh BA Wood Veneer Surround 4 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 11 of 15 Visible Light Transmittance: 0.46 Condensation Resistance: 56 CPD Number: MAR-N-250-00723-00001 ENERGY STAR: NC, SC, S Performance Grade Licensee #898 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 737X1807 mm (30X71.5 in) LC-PG50 DP +50/-50 FL9684 Line #12 Qty: 1 Mark Unit: DINING ROOM MAIN LEVEL Entered As: RO FS 52 1/2" X 60" RO 53 1/2" X 60 1/2" Egress Information No Egress Information available. Performance Information U-Factor: 0.31 Solar Heat Gain Coefficient: 0.23 Visible Light Transmittance: 0.52 Condensation Resistance: 53 CPD Number: MAR-N-252-01081-00001 ENERGY STAR: S Performance Grade Licensee #900 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 1422X1807 mm (57X71.7 in) LC-PG50 DP +50/-50 FL9690 Bronze Exterior Bare Pine Interior Integrity Casement Picture Wood-Ultrex Rough Opening 53 1/2" X 60 1/2" IG - 1 Lite Tempered Low E3 Capillary Tube 4 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #13 Qty: 1 Mark Unit: DINING ROOM MAIN LEVEL Bronze Exterior Bare Pine Interior Integrity Casement - Right Hand Wood-Ultrex CN 17 X Rough Opening 60 1/2" Rough Opening 17" X 60 1/2" IG - 1 Lite Tempered Low E3 Capillary Tube Oil Rubbed Bronze Folding Handle Interior Aluminum Screen Charcoal Fiberglass Mesh BA Wood Veneer Surround 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 12 of 15 Entered As: CN x RO FS 16" X 60" RO 17" X 60 1/2" Egress Information Width: 7 15/64" Height: 55 19/32" Net Clear Opening: 2.80 SqFt Performance Information U-Factor: 0.3 Solar Heat Gain Coefficient: 0.2 Visible Light Transmittance: 0.46 Condensation Resistance: 56 CPD Number: MAR-N-250-00723-00001 ENERGY STAR: NC, SC, S Performance Grade Licensee #898 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 610X1807 mm (25X71.5 in) LC-PG50 DP +50/-50 FL9684 4 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #14 Qty: 2 Mark Unit: ROOF HICKORY EAST BATH Entered As: RO FS 19 3/4" X 23 1/2" RO 20 3/4" X 24" Egress Information No Egress Information available. Performance Information U-Factor: 0.32 Solar Heat Gain Coefficient: 0.19 Visible Light Transmittance: 0.44 Condensation Resistance: 54 Bronze Clad Exterior Bare Pine Interior Clad Ultimate Awning - Roto Operating Rough Opening 20 3/4" X 24" Frame Size 19 3/4" X 23 1/2" Bronze Clad Sash Exterior Bare Pine Sash Interior IG - 3/4" - 1 Lite Tempered Low E3 Capillary Tube Stainless Perimeter Bar Ogee Interior Glazing Profile Standard Bottom Rail Black Weather Strip Oil Rubbed Bronze Folding Handle Oil Rubbed Bronze Multi - Point Lock Interior Wood Screen Charcoal Hi-Transparency Fbrgls Mesh Bare Pine Ogee Interior Screen Profile 6 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 13 of 15 CPD Number: MAR-N-343-04998-00001 ENERGY STAR: S Performance Grade Licensee #921 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 1016X1197 mm (40X47.2 in) LC-PG50 DP +50/-50 FL10323 Line #15 Qty: 2 Mark Unit: ROOF CYPRESS LIVING WEST Entered As: RO FS 19 3/4" X 23 1/2" RO 20 3/4" X 24" Egress Information No Egress Information available. Performance Information U-Factor: 0.32 Solar Heat Gain Coefficient: 0.19 Visible Light Transmittance: 0.44 Condensation Resistance: 54 CPD Number: MAR-N-343-04998-00001 ENERGY STAR: S Performance Grade Licensee #921 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 1016X1197 mm (40X47.2 in) LC-PG50 DP +50/-50 FL10323 Bronze Clad Exterior Bare Pine Interior Clad Ultimate Awning - Roto Operating Rough Opening 20 3/4" X 24" Frame Size 19 3/4" X 23 1/2" Bronze Clad Sash Exterior Bare Pine Sash Interior IG - 3/4" - 1 Lite Tempered Low E3 Capillary Tube Stainless Perimeter Bar Ogee Interior Glazing Profile Standard Bottom Rail Black Weather Strip Oil Rubbed Bronze Folding Handle Oil Rubbed Bronze Multi - Point Lock Interior Wood Screen Charcoal Hi-Transparency Fbrgls Mesh Bare Pine Ogee Interior Screen Profile 6 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #16 Qty: 2 Mark Unit: ROOF CYPRESS EAST UPPER BED Bronze Clad Exterior Bare Pine Interior Clad Ultimate Awning - Roto Operating Rough Opening 20 3/4" X 24" Frame Size 19 3/4" X 23 1/2" Bronze Clad Sash Exterior Bare Pine Sash Interior IG - 3/4" - 1 Lite Tempered Low E3 Capillary Tube Stainless Perimeter Bar Ogee Interior Glazing Profile Standard Bottom Rail Black Weather Strip Oil Rubbed Bronze Folding Handle Oil Rubbed Bronze Multi - Point Lock 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 14 of 15 Entered As: RO FS 19 3/4" X 23 1/2" RO 20 3/4" X 24" Egress Information No Egress Information available. Performance Information U-Factor: 0.32 Solar Heat Gain Coefficient: 0.19 Visible Light Transmittance: 0.44 Condensation Resistance: 54 CPD Number: MAR-N-343-04998-00001 ENERGY STAR: S Performance Grade Licensee #921 AAMA/WDMA/CSA/101/ I.S.2/A440-08 LC-PG50 1016X1197 mm (40X47.2 in) LC-PG50 DP +50/-50 FL10323 Interior Wood Screen Charcoal Hi-Transparency Fbrgls Mesh Bare Pine Ogee Interior Screen Profile 6 9/16" Jambs Nailing Fin ***Note: Capillary tubes will be added to ALL Low E glass types without Argon. Line #17 Qty: 6 Mark Unit: AWNING ADAPTER No Image Available Marvin Parts 05570447 POLE CRANK ADAPTER Line #18 Qty: 1 Mark Unit: AWNING POLE No Image Available Marvin Parts 01590411 POLE CRANK-96", MILL FINISH Line #19 Qty: 1 Mark Unit: DELIVERY FEE Other DELIVERY FEE 07/03/18 OMS Ver. 0002.20.00 (Current) Product availability and pricing subject to change. DENNIS SCALISE SCALISE Quote Number: 3TCFA7Z Architectural Project Number: OMS Ver. 0002.20.00 (Current) Processed on: 6/5/2018 6:54:02 PM Page 15 of 15 Product and Performance Information NFRC energy ratings and values may vary depending on the exact configuration of glass thickness used on the unit. This data may change over time due to ongoing product changes or updated test results or requirements. The National Fenestration Rating Council (NFRC) has developed and operates a uniform national rating system for the energy performance of fenestration products, including windows and doors. For additional information regarding this rating system, see www.nfrc.org/WindowRatings. NFRC energy values and ratings may change over time due to ongoing product changes, updated test results or requirements. Review the map below to determine if your units meet ENERGY STAR for your location. 07/03/18