Loading...
HomeMy WebLinkAboutB18-0262_Approved Documents_1531260678.pdf 40 °Fk4 ,74,„„„mii:,. . ,o, z . . _ .. 11W solar - . . ....i. 4, JVOD"al' SolarEdge Single Phase Inverters 07/10/18 for North America SE3000H—US / SE3800H—US / SE5000H—US / SE6000H—US / SE7600H—US ez,z 0 Solar' - .,,MoD N,Ive \werter -25.6 `1V40:""m 'OJJan°'•. S . . . 4, m e ft a 411 m ,.J 5 45 IP lor Optimized installation with HD-Wave technology Specifically designed to work with power optimizers ▪ Record-breakingefficiency ▪ Fixed voltage inverter for longer strings Integrateda rcfaultprotection and ra pidshutdown for NEC 2014 and 2017, per article 690.11 and 690.12 ▪ UL1741 SA certified, for CPUC Rule 21 grid complia nce Ir ▪ Extremely small and easy to install outdoors or indoors 11111111111 L L• High relia bilitywithout any electrolytic capacitors — Built-in module-level monitoring wave — Optional:Revenue grade data,ANSI C12.2O Class 0.5(0.5%accuracy) in" USA-CANADA-GERMANY-UK-ITALY-THE NETHERLANDS-JAPAN-CHINA-AUSTRALIA-ISRAEL-FRANCE-BELGIUM-TURKEY-INDIA-BULGARIA-ROMANIA-HUNGARY-SWEDEN- WWW.SOIaredge.us SOUTH AFRICA-POLAND-CZECH REPUBLIC • z Single Phase Inverters for North America solar - - tJ)SE3000H-US /SE3800H-US /SE5000H-US /SE6000H-US/SE7600H-U JI 010D.11°11 07/10/18 SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US OUTPUT Rated AC Power Output 3000 3800 5000 6000 7600 VA Ma x.AC Power Output 3000 3800 5000 6000 7600 VA AC Output VoltageMin.-Nom.-Max.(183-208-229) - - ✓ - - Vac AC Output VoltageMin.-Nom.-Max.(211-240-264) ✓ ✓ ✓ ✓ ✓ Vac AC Frequency(Nomina I) 59.3-60-60.5(�) Hz Maximum Continuous Output Current208V - - 24 - - A Maximum Continuous Output Current240V 12.5 16 21 25 32 A GFDI Threshold 1 A Utility Monitoring,Isla nding Protection, Country Configura bleThresholds Yes INPUT Maximum DC Power 4650 I 5900 I 7750 I 9300 11800 W Transformer-less,Ungrounded Yes Maximum Input Voltage 480 Vdc Nomina I DC Input Voltage 380 400 Vdc Maximum Input Current 208V(2) - - 13.5 - - Adc Maximum Input Current 240V(2) 8.5 10.5 13.5 16.5 20 Adc Max.Input Short Circuit Current 45 Adc Reverse-Pola rityProtection Yes Ground-Fa ultlsolation Detection 6001w Sensitivity Maximum Inverter Efficiency 99 I 99.2 % CEC Weighted Efficiency 99 % Nighttime Power Consumption <2.5 W ADDITIONAL FEATURES M Supported Communication Interfa ces RS485,Ethernet,ZigBee(optiona I),Cellula r(optiona I) Revenue Grade Data,ANSI C12.20 Optiona P1 Ra pidShutdown-NEC 2014 and 2017 690.12 Automatic Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741,UL1741 SA,UL1699B,CSA C22.2,Ca na dia nAFCI a ccordingto T.I.L.M-07 Grid Connection Standards IEEE1547,Rule 21,Rule 14(HI) Emissions FCC Pa rt15 ClassB INSTALLATION SPECIFICATIONS AC Output Conduit Size/AWG Range 0.75-1" Conduit/14-6 AWG DC Input Conduit Size/#of Strings/AWG Range 0.75-1" Conduit/1-2 strings/14-6 AWG Dimensions with SafetySwitch(HxWxD) 17.7 x 14.6 x 6.8 /450 x 370 x 174 in/mm Weight with SafetySwitch 22/10 I 25.1/11.4 I 26.2/11.9 lb/kg Noise <25 <50 dBA Natural convection and Cooling Natura(Convection interna Ifa n (user repla cea ble) Operating Temperature Range -13 to+140/-25 to+60141(-40`F/-40'C option)I5l 'F/'C Protection Rating NEMA 3R(Inverter with SafetySwitch) (1)For other regiona(settings plea seconta ctSola rEdgesupport 1i1 A higher current source maybe used;the inverter will limit its input current to the va lues sta ted (3)Revenue gra de inverter P/N:SExxxxH-US000NNC2 {4)Power de-rating from 50'C (')-40version P/N:SExxxxH-US000NNU4 ET: RoHS ©SolarEdgeTechnologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED BYSOLAREDGE are trademarks or registered trademarks of SolarEdgeTechnologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:09/2017/V01/ENG NAM.Subject to change without notice. 0 OF t/4 ....0,12.1....4.,. ii:,, 15., a. ec _ solar - • • it. 1.6b 07/10/18 SolarEdge Power Optimizer Module Add-On For North America P300 / P320 / P400 / P405 CL I - •( owero.o. N ; a 51eats `° , ► waCCan�F hd•aapttN /f d c/ PV power optimization at the module-level — Up to 25% more energy — Superior efficiency(99.5%) — Mitigates all types of module mismatch losses,from manufacturing tolerance to partial shading — Flexible system design for maximum space utilization — Fast installation with a single bolt — Next generation maintenance with module-level monitoring — Module-level voltage shutdown for installer and firefighter safety USA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - ISRAEL - AUSTRALIA www.solaredge.us .5,14094i4r. r solar - • • z SolarEdge Power Optimizer Module Add-On for North America Ji 110'' P300 / P320 / P400 / P405 07/10/18 P300 P320 P4 00 P4 05 (for 60-cell modules) (for high-power (for 72&96-cell (for thin film 60-cell modules) modules) modules) INPUT Rated Input DC Powerm 300 I 320 400 405 W AbsoluteMaximum Input Voltage 48 80 125 Vdc (Voc at lowest temperature) MPPT Operating Range 8-48 8-80 12.5-105 Vdc Maximum Short Circuit Current(lsc) 10 11 10 Adc Maximum DC Input Current 12.5 13.75 12.5 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION(POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 I 85 Vdc OUTPUT DURING STANDBY(POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optimizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B,IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1(class II safety),UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatible inverters All SolarEdge Single Phase and Three Phase inverters Dimensions(WxLxH) 128x152x27.5/ 128x152x35/ 128x152x48/ mm/in 5x5.97x1.08 5x5.97x1.37 5x5.97x1.89 Weight(including cables) 770/1.7 930/2.05 930/2.05 gr/lb Input Connector MC4 Compatible Output Wire Type/Connector Double Insulated; MC4 Compatible Output Wire Length 0.95/3.0 I 1.2/3.9 m/ft Operating Temperature Range -40-+85/-40-+185 'C/`F Protection Rating IP68/NEMA6P Relative Humidity 0-100 % Ill Rated STC power of the module.Module of up to+5%power tolerance allowed. PV SYSTEM DESIGN USING SINGLE PHASE THREE PHASE 208V THREE PHASE 480V A SOLAREDGE INVERTER(2) Minimum String Length 8 10 18 (Power Optimizers) Maximum String Length 25 25 50 (Power Optimizers) Maximum Power per String 5250 6000 12750 W Parallel Strings of Different Lengths or Orientations Yes RI It is not allowed to mix P405 with P300/P400/P600/P700 in one string. CE Eta ©SolarEdge Technologies,Inc.All rights reserved.SOLAREDGE,the SolarEdge logo,OPTIMIZED B YSOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies,Inc.All other trademarks mentioned herein are trademarks of their respective owners.Date:02/2015 V.01.Subject to change without notice. Mono Multi Solutions 11 C c4 err r � IIhIIIILHJk THE � ` o� 1710 1 ; III•IIII I, Ai. MAXpLus� FRAMED 60-CELL MODULE ' 60 CELL • MONOCRYSTALLINE MODULE 275-305W POWER OUTPUT RANGE Maximize limited space with top-end efficiency 18.6% •Up to 186 W/m2 power density •Low thermal coefficients for greater energy production at high MAXIMUM EFFICIENCY operating temperatures Oti+5W C0) Highly reliable due to stringent quality control •Over 30 in-house tests(UV,TC,HF,and many more) POSITIVE POWER TOLERANCE •In-house testing goes well beyond certification requirements •PID resistant •100%EL double inspection Founded in 1997,Trina Solar is the world's leading comprehensivesolutions provider for solar energy.we believe close cooperation with our partners is critical to success.Trina Solar now distributes its PV products Certified to withstand the most challenging to over 60 countries all over the world.Trina is able to '''',---NN2 environmental conditions provide exceptional service to each customer in each market and supplement our innovative,reliable VIIV •2400 Pa wind load products with the backing of Trina as a strong, bankable partner.We are committed to building •5400 Pa snow load strategic,mutually beneficial collaboration with •35 mm hail stones at 97 km/h installers,developers,distributors and other partners. Comprehensiv eProducts And System Certificates IEC61215/IEC61730/UL1703/IEC61701/IEC62716 ISO 9001:Quality Management System ISO 14001: Environmental Management System 15014064:Greenhousegases EmissionsVerification OHSAS 18001: Occupation Health and Safety Management System LINEAR PERFORMANCEWARRANTY 10 Year Product Warranty• 25 Year Linear Power Warranty g ST .g (E LISTED 100% - 97% 4dditio ISO ��� � rvv�e o 90% nal value from Trina Solar'slinearwarranty 2 80% Years 5 10 15 20 25 Trinasolar • Trina Linear Warranty Standard Step Warranty vof 1,041 AL[ MAX • 41111111111161: . �PLu60-CELLol.g,a FRAMED ec PRODUCTS POWER RANGE ELECTRICALDATA(STC) 1201 TSM-DDO5A.08)II) 280-305W TSM-DDO5A.05)II) 275-300W Peak Power Watts-PMAx(Wp)* 275 280 1 285 290 295 R10/18 305 Power Output Tolerance-Pwoi(W) 0-+5 Maximum PowerVoltage-VMPP(V) 31.4 31.7 31.8 32.2 32.5 32.6 32.9 DIMENSIONS OF PV MODULE(mm/inches) Maximum Power Current-MPP(A) 8.76 8.84 8.97 9.01 9.08 9.19 9.28 941/37.0 il Open Circuit Voltage-Voc(V) 38.7 39.0 39.3 39.5 39.7 39.9 40.2 11-i, Short Circuit Current-kc(A) 9.26 9.35 9.45 9.50 9.55 9.64 9.72 Junction Box A i Module Efficiency (%) 16.8 17.1 17.4 17.7 18.0 18.3 18.6 � SIC:Irradiance 1000W/m',Cell Temperature25°C,Air Mass AM1.5. Nameplate *Measuring tolerance:±3%. ELECTRICALDATA(NOCT) Maximum Power-PMAx(Wp) 205 209 212 216 220 223 227 Maximum PowerVoltage-VMPP(V) 29.2 29.4 29.6 29.9 30.2 30.4 30.6 e Maximum Power Current-MPP(A) 7.02 7.10 7.17 7.23 7.28 7.35 7.42 4-09x12 Installing Hole Open Circuit Voltage-Voc(V) 36.0 36.3 36.6 36.7 36.9 37.1 37.3 6-04.3 Grounding Hole Short Circuit Current-kc(A) 7.48 7.55 7.63 7.67 7.71 7.78 7.84 12-Drain Hole NOCT:Irradiance at 800W/m',Ambient Temperature 20°C,Wind Speed 1 m/s. • "I I IMI MECHANICAL DATA 35/1.38 992/39.1 Solar Cells Monocrystalline 156.75 x 156.75 mm(6 inches) Back View Cell Orientation 60 cells(6 x 10) 11/0.43 silicon Sealant Module Dimensions 1650 x 992 x 35 mm(65.0 x 39.1 x 1.38 inches) _ff [aminate vej 4 Weight 18.6 kg(41.0 Ib) 00 0 66 Glass 3.2 mm(0.13 inches),High Transmission,AR Coated TemperedGlass Backsheet White[DDOSA.08(1)]; M Frame Black[DD05A.051I)] 1 35/1.38 Frame Black Anodized Aluminium Alloy[DDO5A.08(0),DDO5A.05)I)] (A-A) J-Box IP 67 or IP 68 rated Cables Photovoltaic Technology Cable 4.0mm'(0.006 inches'), 1000 mm(39.4 inches) 1-V CURVES OF PV MODULE(305W) no Connector MC4 or Amphenol H4/UTX 9.0 1000W/m' 80 800W/m' Fire Type Type 1 orType2 z0 <• 6.0 oww/7 • 6.0 3.0 2.0 200,./‘W1 TEMPERATURERATINGS MAXIMUM RATINGS o ----1 NOCT(NpminalOperating Cell Temperature) 44°C(±2°C) Operational Temperature -40-+85°C 0 10 20 30 40 50 Voltage(V) TemperatureCoefficientof PMAx -0.39%/°C Maximum System Voltage 1000VDC(IEC) P-V CURVES OF PV MOD ULE(305W) TemperatureCoefficient of Voc -0.29%/°C 1000V DC(UL) 350 TemperatureCoefficient oflx 0.05%/°C Max Series Fuse Rating 15A 1000W/m' 300 (DO NOT connect Fuse in Combiner Box with two or more strings in 250 - - parallel connection) 3 200 0 Iso WARRANTY PACKAGING CONFIGURATION 100 `11_ so / `111_ 10 year Product Workmanship Warranty Modules per box:30 pieces 10 20 30 40 50 25 year Linear Power Warranty Modules per 40'container:840 pieces Voltage(V) (Please refer to product warrantyfor details) [\'' CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. I I na SO l a l" m 2017 Trina Solar Limited.All rights reserved.Specifications included in this datasheetare subject to change without notice. Version number:TSM_EN_2017_B www.trinasolar.com