Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
A18-0041_approved documents_1538156623.pdf
75 South Frontage Road Fire-Construction Permit West, TOWN OF VAIL A18-0041 Vail,CO 81657 Issued: 09/28/2018 TOWN of VAIL0.ZOffice:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 548 S FRONTAGE RDW(210106312999)(210106312999) Unit#: ParcelNumber: 210106312999 LegalDescription: Contacts ContactType:Applicant Full Name:Don Anderson Address: PO Box 3940 331 MetcalfRd Avon,CO 81620 Phone: 9707488888 ContactType:PropertyOwner Full Name:Common Area Address: Phone: None Contractor Contractor Type:Fire Protection Company: Meridian Intermountain/Vail Electronics State License#: Phone: 970-748-8888 Projectlnformation ProjectName:Westwind 2017 ProjectDescription: ReplaceAlarm panel,and all existing devices. Fees Paid Accounl#:001-0000.31111.00 Fire Alarm Permit Fee Fee Amount: $356.25 Accounl#:001-0000.31123.00 Fire Alarm ReviewFee Fee Amount: $288.00 TotalPaid: $644.25 Conditions Issued By:Town of V ailFire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicant agrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicant shall forfeitall applicable fees. Small Building Fire Alarm Solutions ,lid Kidde nv United Technologies Technology that saves lives - SW. �- iti: Intelligent Fire = __ == AlarmSystems M VS1, VS4 FDNY COA 6229 taaiii 7165-1657: 0244 0 C S3000 Overview Features Kidde brand intelligent life safety systems offer the power of high- • Auto-programming speeds installation time end intelligent processing in configurations that deliver uncompli- • Supports V-Series intelligent modules and detectors cated solutions forsmall to mid-sized applications.With intelligent detection,electronic addressing,automatic device mapping, • FormC contacts for alarm and trouble,FormA forsupervisory optional Ethernet®connectivity, and a full line of easily-configured • Electronic addressing with automatic device mapping option cards and modules,these flexible systems offer versatility . Optional Ethernet port for diagnostics,programming and a that benefits building owners and contractors alike. variety of system reports The VS1 provides one Class A or Class B intelligent device loop • Two programmable switches with LEDs and custom labeling that supports up to 64 device addresses,and two Class B Notifi- cation App liance Circuits(NACs).Optional Class A device wiring is • Supports Genesis horn silence overtwo wires,and UL available with the use of a module. 1971-compliant strobe synchronization • The VS4 provides one Class A or Class B intelligent device Supports GSA REL releasing module for fire suppression loop that supports up to 250 device addresses.Loop controller • Class B or Class A wiring modules may be added in combination to expand total system • Ground fault detection by module capacity in 250-point increments to up to 1,000 device addresses. VS4 panels include four NACs that may be wired for either Class A • Supports up to eight serial annunciators, (LCD,LED only, and or Class B operation. graphic interface) TheRZ/16-2 module adds even mo re capacity to VS installations • Can use existing wiring for most retrofit applications by adding up to 16 conventional device circuits and two additional • Upload/download remotely or locally notification appliance circuits.This makes them ideal retrofit solu- • Two-level maintenance alert reporting tions that can accommodate new intelligent detectors,as well as • Pre alarm and alarm verification by point existing conventional devices. • Adjustable detector sensitivity VS Series supports a wide range of high-end features, including: • • Intelligent modules,detectors, and bases 4 x 20 character backlit LCD display • GSA RELReleasing Modules • Optional earthquake hardening:seismic Importance Factor 1.5 • R-Series remote annunciators • Standalone operation • Integrated Carbon Monoxide gas sensing with V-PCOS de- • Transmission test frequency by hour tectors including distinct audible signaling • Alarm ON command manually activates alarm condition Page 1 of 8 D ATA SHE E . V85005-0135 Not to be used for installation purposes. Issue 1.3 Application Kidde VS Series life safety systems are powerful intelligent solutions of strobes to UL 1971 standards.For Genesis devices,enabling fo r small to mid-siz edb uildings.Advanced intelligent technology this feature allows horns to be silenced while strobes on the same delivers the benefits of flexible system installation,while clean and two-wire circuit continue to flash until the panel is reset. easy-to-operate user interfaces make panel operation and system maintenance quick and intuitive. Flexibility built right in Two fully-programmable front panel switch/LED combinations provide Th esmart choice an added measure of flexibility.Theirslide-in labels take the mystery Electronic addressing eliminates the tedium of setting dip switches, out of custom applications,and present a clean finished appearance. and automatic device mapping ensures that each device resides on the system at its correct location.Meanwhile,innovative pro- Perfect for retrofits gramming allows the designer to customizethe system to pre- Kidde VS Series control panelsare particularly well-suited to cisely suit the needs of the building owner. retrofit applications.All co nnectio nsare made over standard wiring -no shielded cable required.This means that in most situations Reliability you can count on existing wiring can be used to upgrade a legacy control panel The inherent fault-tolerant characteristics of Analog/Address- to VS technology without the expense or disruption of rewiring ab le Technology boosts the reliability of Kidde fire alarm systems. the entire building.VS control panels also support the ingenious When combined with VS Series smoke and heat detectors,these RZI16-2 z onemodule,which adds up to 16 conventional circuits systems deliver a level of dependability not previously available and two NACs.This combination easily accommodates new intel- fo r small to mid-siz ed applications.All Kidde systems are built to ligent detection alongside existing conventional circuits,making it exacting reliability benchmarks and meet international standards an superior solution in the retrofit market. for quality,in addition to agency listings for dependability. Scalable IP and Cellular Communications Clear-cut remote annunciation Several popular third-party IP/Cellular communicators have been Remoteannunciation is a strong suit of the VS Series fire alarm tested with the VS control panels and are compatibility listed to systems.Up to eight annunciators can be installed on a single UL864.The IP/Cellular communicators meet NFPA72 2013 edition system.Compatible annunciators include a range of LED and LCD requirements for sole or secondary transmission paths.Using IP/ models that provide z o neor point annunciation, as well as co m- Cellular communicators can reduce the cost of ownership by mon control capabilities.VS control panels also supports grap hic eliminating POTS lines. Please see the VS control panel compat- annunciation with optional graphic annunciator interface modules. ibilitydocumentationpart number3102354-EN fora full list of Each interface provides common control and 32 LEDs. compatible communicators. Signals with a difference A complete line of accessories VS Series NACs are configurable to fully support the advanced VS Series life safety systems are supported by a complete line of signaling technology of Kidde Genesis and Enhanced Integrity no- analog/addressable detectors, modules and related equipment. tification appliances.These devices offer precision synchronization Consult the Ordering Information section for details. Programming and remote diagnostics Dimensions Kidde VS Series life safety systems are simple to set up,yet offer 01 62+� 03 (?) (9) Ida advanced programming features that put these small building tD7H panels into a class of their own.The auto programming featureD •O • o•0 '0 - quickly gets the panel operational using factory default settings. I° eD .D Basiczoneand point settings can be programmed through the 0 0 front panel interface,so the system is up and running in no time. 1 I o 0 0 For mo re advanced system configuration and correlation groups D' . II pA programming,VS Series systems interface to a PC running corn- - _ • patible VS-CU software.This option offers full system configura- D O tion in the familiar Windows®operating environment. Connection is ® $ • made to a laptop through the panel's optional RS-232 communi- , cations port,which can also be used to connect a system printer. 1.-06 J *DOI 4D9e• Among the many innovative features of VS Series control panels is the optional network card.This module provides a standard (1)Surface Mounting Holes (3)Backbox with Door Attached 10/100 Base T Ethernet®network co nnectionthat permits access (2)Semi-flush mounting Holes (4)Backbox with door and trim kit attached. to the control panel from any remote location with the correct communications protocols.The connectioncan be used to down- Panel dimensions,in(cm) load to the panel from the VS-CU,or upload and view system Model D1* D2 D3 D4 D5• D6 D7 D8 D9 reports using the VS-CU. vs4 28.0 3.85 9.0 22.0 15.75 10.25 4.9 30.1 2.7 (71.1) (9.8) (22.8) (55.8) (40.0) (26.0) (12.4) (76.4) (6.8) Available system reports include: Correlation groups,Device de- vs, 21.5 3.85 7.5 15.5 14.25 10.25 4.9 23.6 2.7 (54.6) (9.8) (19.0) (39.4) (36.2) (26.0) (12.4) (59.9) (6.8) tails,Device maintenance,History, Internal status,System configu Add 1-1/2 in.(3.81 cm)to Dl and D5 dimensions fortrim kit.T hetrim kit ration,System status,Walk test,Dialer, and CO runtime. provides 0.75 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. a fin Page2of8 DATA SHEET V85005-0135 Not to be used for installation purposes. Issue 1.3 System Layout VS4 Any combination of two single-or dual device loop modules Standard Loop:250 points(one expansion slot) V-SLC2-2 Expander,Loop 1 of 2:250 points Up to 125 sensors and 125 modules per loop (one expansion slot) " - il].. • ...........„. ,_ft............. V-SLC2-1 Expander Loop:250 points(one expansion slot) V-SLC2-2 Expander,Loop 2 of 2:250 points ,Up to 20,000 feet of wiring per loop f E___,,--'rmt IllpFIRE • FIRE FIRE - FIRE FIRE FIRE FIRE g- -'`j'� Four Class Bortwo o optional w,. Four Classortwooptional ClassANACs p Optional 10 A or 6.5 A Booster GI Ethernet(SA-ETH) ii DACT/Dialer(SA-DACT)U-' Up to eight remote a nunciators RS-232(SA-232) "4 • Sixteen Conventional IDCs, 1 Relays:Two Form C,one FormA two additional NACs with RZI16-2 module Each VS4 panel has room for up to two device loop controller modules in any combination of single or Panel Layout dual 250-device loops.VS4 comes with one loop that supports up to 125 detectors and 125 modules. 4 0 '00008 b0 3 5 Q:■■ir VS1 2 _ 0 L:.. . .,,R 6 II L MFS=-�,� � �i� � I � m 9 r— � � ) OCI mooMi 00:0 Loop supports up to 64 intelligent dev icesof any type. o's `'a 10 U to 20,000 feet of wirin e.n 11 Up g• `12 e.. -- a ..;;1:... - �� 1 12 FIRE FIRE FIREO o Q 13 Two Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster Power Supply o s z 1:1 1 Transformer Up to eight r nunciators , ... 2 Main AC wiring block&fuse holder 3 RS-232 card connector(J3) Ethernet(SA-ETH) • 4 Dialer cardconnection(J8) DACT/Dialer(SA-DACT) 5 Ethernet card connector(J1) 6 Main circuit board RS-232(SA-232) 7 Panel backbox enclosure Relays:Two FormC,one FormA 8 Operator interface 9 SLC card connector(J7) 10 Class A card connector(J2) Tie Each VS1 panel ships with one device loop controller that sup- 11 LED expan ports 64 devices of any type.This panel's device capacity cannot 12 LED connector(J6) 13 Standby batteries be expanded. Page3of8 DATA SHEE , V85005-0135 Not to be used for installation purposes. Issue 1.3 Wiring & Configuration Device loop Auxiliary&smoke power outputs(TB3) The system provides one device loop circuit with a total capacity The control panel provides two auxiliary power I . of 125 detectors and 125 module addresses.The loop circuit is outputs that can be used for powering ancillary 0—No supervised for o pens,sho rts,and grounds. equip ment such as remote annunciators and two (1) wire smoke detectors. Aux 2 can be software NC Circuit VS4 VS1 selected to operate continuously.The circuit is 0—1 specifications Device loops One Class B orA One Class B or A loop, supervised forshortsand grounds. loop,supporting 125 supporting 64 devices of Circuit specifications (2) 0=NO detectors and 125 any kind. Circuit voltage 21.9 to 28.3 V modules.Expandable to range 0 NC four loops. Resettable circuit 24 VDC nominal at 500 mA (3) CO Communication Maximum 20 V peak-to-peak (Aux power 2) NO line voltage Circuit current 0.5 A max Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering 0 Circuit 660 total,0.5 NF,max two-wire smokedetectors. impedance (4) 0 Isolators 64 maximum Note:Any current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that 0 Signal Supported on a system-wide basis(all device loops) amount. — Synchronization when using an addressable notification appliance (1)Trouble circuit(NAC)module and Genesis or Enhanced Integrity notification appliances. (2)Supervisory Alarm,trouble,and supervisory relay(TB3) (3)Alarm Class wiring Class A wiring The trouble relay is normally-open, held closed, and openson any trouble event or when the (4)Smoke/Aux SLCA - Data Line SLCA -® panel is de-energized.The supervisory relay is + —I normally-open, and closes on any supervisory SLC B ,�����(e1� •SLC B .® ��(e - — event.The alarm relay changes over on any Loop Loop Loop Loop Loop card device device Loop card Data Line device device alarm event. Relay specifications Alarm I Trouble Supervisory Notification appliance circuits(TB2) Type FormC FormA VS4 control panels come equip pedwith four notification appliance Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive circuits.VS1 control panels come with two NACs.Each circuit can Relay circuits can only be connected to power-limited sources. be individually configured for continuous,temporal, synchronized, and coded output. Specifications VS4 VS1 Annunciator loop(TB4) Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A The control panel provides a connection for up to eight serially with SA-CLA module driven and supervised remote annunciators. Voltage 24 VFWR Current 6.0 A total,2.5 A max. 3.75 A total,2.5 A max. Circuit specifications per circuit at 120/230 per circuit at 120/230 Device loops Class B(Style Y)or Class A(Style Z) VAC 60 Hz. VAC 60 Hz. Circuit voltage 2.55 V 5.0 A total,2.5 A max. 3.0 A total,2.5 A max. Circuit current 30 mA max per circuit at 230 VAC per circuit at 230 VAC Circuit Up to 8 annunciators or 4000 feet 50 Hz. 50 Hz. impedance Impedance 26 0 total,0.35 pF max EO LR 15 K 4,1/2 W Class B Class A Synchronization Supported system-wide Channell Channell Channel 1 Channel 2 f — f — f — f — Class B wiring Class A wiring is ® i ® TB4 ® ® ® TB4 NAC1- 0 NAC1- + + O NAC1+ .N.7NIMI 0 NA1+ C a - < Annunciator Annunciator 0 NAC2- EOLR 0 NAC2- �CH1(+)IN �CH1(+)IN NAC2- /IL a + 0 + +NAC2+ I - a - a ®CH1(-)IN CH1(-)IN TB2 TB2 O NAC3 + + i. 0 - 5 CH2(+)IN &CH2(+)IN NAC3+ a - a y 0 + S CH2(-)IN 5 CH2(-)IN 0 NAC4- + + EOLR O NAC4+ a a 0 + TB6 TB6 Marking indicates output signal polarity when the circuit is active.Polarity reverses when the circuit is not active.Wire notification appliances accordingly.Notification appliance polarity shown in active state. 0 fin Page4of8 DATA SHEET V85005-0135 o V Not to be used for installation purposes. Issue 1.3 Option Cards Kidde VS Series panels are supported by a complete line of mod- RZI16-2 Remote Zone Interface Module ules and related equip ment that enhance performance and extend — system capabilities. Option cards p lug directly into the control a,a,s. panel main circuit board or are connected to it with a ribbon cable. _ :; 1 -®°` After installation,terminals remain accessible.The cabinet pro- a,-- vides ample room for wire routing,keeping wiring neat at all times. Q :- llf ®� ®li Single and Dual Loop Controller Cards The RZI16-2 Addressable RemoteZone Interface Module is an The V-SLC2-1 is a single loop controller card that can be used addressable device that provides connections for sixteen Class B with the VS1 as a replacement forthe standard 64-point loop,or Initiating Device Circuits and two Class B Supervised Output with the VS4 as a 250-point expansion module. Circuits.The inputs and outputs can be configured individually for The V-SLC2-2 is a 500-point dual loop controller card forthe VS4 several device types. that provides two IDC circuits,each with 125 detector addresses The RZI16-2 requires 18 consecutive addresses on the Signaling and 125 module addresses. Line Circuit(SLC).Addresses are assigned electronically.There are no address switches to set. Specifications V-SLC2-1 V-SLC2-2 Device Addresses VS4:one loop,250 VS4:two loops,500 The RZI16-2 incorporates two 8-segment DIP switches that are device addresses device addresses used to select the Alarm or Supervisory default device type for VS1: 64 addresses each of the 16 IDC circuits.The module also includes one 4-seg- Wiring Class B or Class ment DIP switch used to select the default Relay or NAC output Operating Voltage 24 VDC device type.Device types other than the default are accomplished Operating Current Standby:55 mA Standby:45 mA through programming. (fully loaded loop) Alarm:80 mA Alarm:70 mA Note:T heseratings do not include the use of two-wire smoke modules. RZI16-2 Specifications Communication Line Max.20.6 V peak-to-peak Voltage Voltage 24V/Aux nominal: 24 VDC Terminal Rating 12 to 18 AWG(0.75 to 2.5 mm2) Supervisory current: 250 mA at 24 VDC nominal Alarm current: 1000 mA Circuit Current 0.5 A max. 24V/Aux minimum: 18.4 VDC Max total loop 66 0 24V/Aux maximum: 26.4 VDC resistance NAC1, NAC2 nominal: 24 VDC Max total loop 0.5 uF Current capacitance Standby current Isolators 64 isolators maximum per loop(total both for4.7 k EOL(U.S.) 4.8 mA/circuit isolator bases and modules) Standbycurrentfor Ground Fault 0 to 5 kf2 3.9 k EOL(Canada) 5.7 mA/circuit Impedance Alarm current Operating 32 to 120°F (0 to 49°C) at nominal voltage 31.1 mA/circuit Environment 0 to 93%no ncondensing at 90°F(32°C) Relay outputs Quantity 2 Type Rating(pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire SA-ETH Ethernet Interface Card resistance SA-ETH wiring The SA-ETH card provides a Initiating device circuits ^ To network 1� �� connection standard 10/100 Base T Ether- Quantity 16 Network cable .I• net network Connectionfor EOL resistor 4.7 kO(U.S.);3.9 kO Canada MI connecting to an intranet,a local Zone voltage 22.78 V for 4.7 kQ(U.S.) network, or the Internet.The 22.08 V for 3.9 kO(Canada) 1 Alarm current 31.1 mA/channel at nominal voltage 0 I"°„°°°E°°Eu�l ® card can be used to download Alarm impedance range <680 0 P17 configuration programming from Trouble impedance range >5.55 kO ° ® the VS-CU to the panel. Supervised output circuits t. UlThe Ethernet card is installed on EOL resistor 15 k0®� Quantity 2 the plastic assembly and con Short circuit detection <2.6 kQ -? nects to the main circuit board Ethernet card Opencircuitdetection >61.9k4 via a ribbon cable. Contact ratings 24 VDC at 2.5 A(5 A fortwo NACs) SA-ETH specifications Compatible cabinets MFC(A),VS4,APS Ethernet 10/100 BaseT Operating environment Temperature 32 to 120°F (0 to 49°C) Humidity 0 to 93%RH,noncondensingat 90°F (32°C) Page5of8 DATA SHEE , V85005-0135 Not to be used for installation purposes. Issue 1.3 SA-DACT Dialer SA-232 RS-232 interface The SA-DACT provides communications between the control The SA-232 card provides an RS-232 in- GND wiring panel and the central station over telephone line system.It terface with VS panels.It can be used for GND(black wire) p p Y TXD(white wire) transmits system status changes(events)to a compatible digital connecting a printer to the control panel r RXD(red wire) alarm communicator receiver over the public switched telep hone to print system events.The card also network.The dialer is capable of single,dual,or split reporting can be used for connecting a computer +GGG6 � of events to two different account and telephone numbers.The to download a configuration program 0 modem feature of the SA-DACTcan also be used for uploading from the VS-CU to the control panel. and downloading panel configuration,history, and current status The RS 232 card is installed on the p las to a PC running the VS-CU. tic assembly and connects to the main circuit board via a ribbon SA-DACT Phone line 2 cable. wiring BTowel! Phone line 1B phonejack SA-232 specifications Phone cables Operating voltage Standard EIA-232 . (supplied) �I RJ3ljacks n n � Terminal rating 12 to 18 AWG(0.75 to 2.5 sq mm) I•I I•I Operating environment The dialer phone lines connect to Temperature 32 to 120°F (0 to 49°C) I+ +I connectors on the dialer's main Humidity 0 to 93%RH,noncondensing at 90°F(32°C) '..'_o°9: circuit board.Phone line 1 connects ® " O to connector J4 and phone line 2 EC571,Z1=1,;167: connects to connector Ji. _ ° ° f1 SA-CLA Class A Module(VS1 only) °11E1 ° n�e e=°o°� The SA-CLAcardprovides Class A capability for NAC wiring. °❑❑— ° ° o Its terminal block provides the wiring connection for NAC return 0o`s0 o wiring.The card is required for annunciator Class A wiring even though this wiring does not return to the SA-CLA card.The SA- The SA-DACTqueues mes- CLA is compatible with VS1 control panels only.VS4 panels are sages and transmits them based on priority(alarm,supervisory, Class A Ready.The SA-CLA is installed directly to the control trouble,and monitor).Activations are transmitted before restora- panel circuit board using its plastic standoffs and plug connection. tions. SA-CLA specifications The SA-DACT is installed on the plastic assembly and connects to Operating voltage 24 VFWR the main circuit board via a ribbon cable. Operating current 3.75 A FWR total at 120/230 VAC 60 Hz SA-DACT specifications 3.0 A FWR total at 230 VAC50 Hz 2.5 A max per circuit Phone line type One or two loop-start lines on a public, Circuit impedance 26 ohms,0.35uF switched network Terminal rating 12 to 18 AWG(0.75 to 2.5 sq mm) Phone line connector RJ-31/38X(C31/38X) Operating environment Communication formats Contact ID(SIA DC-05) T Temperature 32 to 120°F (0 to 49°C) Operating environment Humidity 0 to 93%RH,noncondensing at 90°F Temperature 32 to 120°F (0 to 49°C) (32°C) Humidity 0 to 93%RH,noncondensing at 90°F (32°C) Comp atible DACRs D16L-VS LED Disp lay Expander(VS4 only) Receiver Models Formats The D16L-VS LED Display Expanders provide LED annuncia- Ademco 685 Contact ID tion for up to 16 z ones.lt provides two LEDs for each z one.Two FBI' CP220 Contact ID D16L-VS LED display expanders can be installed in each VS4 Osborne-Hoffman OH 2000 Contact ID panel. Bosch D6600 Contact ID Silent Knight 9800 Contact ID (1} (3} (d} IF I Sur-Gard SG MLR1,MLR2 Contact ID (2) ® OI I S® I I l I 81 1 $1 I I I I I 2,1 I it I 0 = $I 1I zooa- ii 1 I I l I 1 I I p 1 — 0 1 I — I of 1 I lam_ (1)LED 1 (5) (2)LED 2 (3)LED Expander 1 (4)LED Expander 2 (5)Alarm/non-alarm and trouble z oneLEDs 0 fin Page6of8 DATA SHEET V85005-0135 o V Not to be used for installation purposes. Issue 1.3 Specifications VS1 VS4 Device loops 1 loop Class B or Class A(Styles 4,6,7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 modules) detectors and 125 modules max.).Addresses 1 to 125 are MaximumT--taps:63 for detectors and addresses 126 to 250 areformodules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B(Style Y),Class A(Style Z)optional 4 Class B(Style Y)or 2 Class A(Style Z) circuits 3.75 A FWR total at 120/230 VAC60 Hz 6.0 A FWR total at 120/230 VAC60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC50 Hz 2.5 A FWR each max.per circuit 2.5 A FWR each max.per circuit Primary power 120 VAC,60 Hz,1.3 A max. 120 VAC,60 Hz,2.0 A max. 230 VAC,50-60 Hz,0.62 A max. 230 VAC,50-60 Hz,0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA Input zones 16 max. 32 max. Remoteannunciator 8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B Data line length:4,000 ft.(1,219 m) Data line length:4,000 ft.(1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1: 500 mA,24 VDC circuit Aux power 2:500 mA,24 VDC(1 A possible if you reduce total available NAC power by 500 mA) Output:28.3 to 21.9 VDC,special application Note:Fora list of compatible devices,see the VS1 and VS4 Series Compatibility List(P/N 3102354-EN) Loop circuit Maximum loop resistance:66 0 Maximum loop capacitance:0.5 pF Communication line voltage:Maximum 20.6 V peak-to-peak Operating current(fully loaded loop)Stand by:55 mA/45 mA Alarm:125 mA/115 mA(not including two-wire smoke modules) Circuit current:0.5 A max.Style 4,6,and 7 wiring Max.resistance between isolators: Limited only by overall wire run lengths 64 isolators maximum per loop(total both isolator bases and modules) Batteries Type:Sealed lead acid Voltage:24 VDC Charging current:2.47 A max.Amp hour capacity:26 Ah Standbyoperation:24 hour or 60 hour Placement:Up to two 10 Ah batteries will fit in the VS1 control panel cabinet and two 18 Ah batteries will fit in the VS4 control panel cabinet.If larger batteries are required,use a battery cabinet. SA-DACTdialer Phone line type:One or two loop-start lines on a public,switched network Phone line connector: RJ-31/38X(C31/38X) Communication formats:Contact ID(SIA DC-05) Operating current Standby/Alarm:41 mA Max.:100 mA FCC registration number:GESALO1 BSADACT Industry Canada Registration number:3944A-SADACT Ringer equivalence number:0.1B Ground fault impedance 0 to 5 kfl Alarm contact FormC N.O.24 VDC at 1 A(resistive load) Trouble contact FormC 24 VDC at 1 A(resistive load) Supervisory contact FormA N.O.24 VDC at 1 A(resistive load) Environmental Temperature:0 to 49°C(32 to 120°F) Relative humidity:0 to 93%noncondensing Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm2) Page7of8 DATA SHEE . V85005-0135 Not to be used for installation purposes. Issue 1.3 — Ordering Information Kidde Part Description ® VS4 Fire Alarm Systems VS4-G Four loop system with one 250-point loop installed.110v, gray door. Technology that saves lives VS4-G-2 Four loop system with one 250-point loop installed.230v,gray door. VS4-G-2-PG Four loop system with one 250-point loop installed.230v,gray door,Portuguese. Contact us... VS4-G-2-SP Four loop system with one 250-point loop installed.230v,gray door,Spanish. Email:kidde.fire@fs.utc.com VS4-GC Four loop system,one 250-point loop installed.110v, gray door,LED strips,Canada. Web: Kidde.com/EngineeredSystems VS4-GD Four loop system,one 250-point loop installed.110v, gray door,with dialer. VS4-GF Four loop system,one 250-point loop. 110v, gray door, LED strips, French Canada. VS4-G-PG Four loop system with one 250-point loop installed.110v, gray door,Portuguese. Kidde is a UTC brand. VS4-G-SP Four loop system with one 250-point loop installed.110v, gray door,Spanish. 1016 Corporate Park Drive VS4-R Four loop system with one 250-point loop installed.110v, red door. Mebane,NC 27302 VS4-R-2 Four loop system with one 250-point loop installed.230v,red door. ©2017 United Technologies Corporation. VS4-RD Four loop system,one 250-point loop installed.110v, red door,with dialer. All rightsreserved. SA-TRIM2 VS4 Flush mount trim,black. VS1 Fire Alarm Systems VS1-G One loop system with one 64-point loop installed.110v, gray door. VS1-G-2 One loop system with one 64-point loop installed.230v,gray door. VS1-G-2-PG One loop system with one 64-point loop installed.230v,gray door,Portuguese. VS1-G-2-SP One loop system with one 64-point loop installed.230v,gray door,Spanish. VS1-GD One loop system,one 64-point loop installed.110v, gray door,with dialer. VS1-GL One loop system,one 64-point loop installed.110v, gray door,English Canada. VS1-GL-F One loop system,one 64-point loop installed.110v, gray door,French Canada. VS1-G-PG One loop system with one 64-point loop installed.110v, gray door,Portuguese. VS1-G-SP One loop system with one 64-point loop installed.110v, gray door,Spanish. VS1-R One loop system with one 64-point loop installed.110v, red door. VS1-R-2 One loop system with one 64-point loop installed.230v,red door. VS1-RD One loop system,one 64-point loop installed.110v, red door,with dialer. SA-TRIM1 VS1 Flush mount trim,black Option Cards V-SLC2-1 Expansion module,one 250-device loop.For VS4 only. V-SLC2-2 Expansion module,two 250-device loops,500 devices total.ForVS4 only. RZI16-2 Remote Zone Interface Module.16 Class B IDCs,2 Class B Output.Bracket included. SA-DACT Dual Line Dialer/Modem,supports Contact ID,mounts in cabinet on baseplate. SA-232 RS-232 Serial Port forconnectionto printers&computers,mounts in cabinet. SA-ETH Ethernet Port,Slave,mounts in cabinet on baseplate. SA-CLA Class A adapter module.Provides Class A capacity on NACs.Mounts in cabinet on main board.VS1 systems only. D16L-VS LED Annunciator module,16 X 2-LED z ones(4 programmable forsup). Mounts in cabinet to right of LCD display. For VS4 only. D8RY-VS Canada only:LED Annunciator module,two LEDs per zone,16 z ones(4 alarm only, 8 supervisory only,4 alarm or supervisory).Mounts in cabinet.ForVS4 only. Accessories CTM City Tie Module.2-gang.Connectionto a local energy fire alarm box. MFC-A Multifunction Fire Cabinet,8"x 14" x 3.5"-red. BC-1 BatteryCabinet. 14.0" x 18.25" x 7.25". Holds two 12V24A batteries. BC-1R Battery Cabinet-Red.14.0"x 18.25"x 7.25".Holds two 12V24A batteries. GSA-REL Releasing Module BC-1EQ Seismic hardening Kit for VS Series panels.Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools VS-CU VS Series configuration and diagnostics utility. 260097 RS232 cable,4 conductor,DB9 PC interface a 9 Page8of8 DATA SHEET V85005-0135 Not to be used for installation purposes. Issue 1.3 Kidde Catalog PowerSuppliesand Accessories 4,r 0-- 0 Kidde United Technologies - Technology that saves lives \\\%4II\\MIIIIIII lll lililllllj�� i11,,l�it,,. Aemote Booster iiii PowerSupplies ..,.fpit. 0 MIRBPS6A MIRBPS10A ilii.. ., '{1y • ll1.11!(IIII S3424 ity,i{{lllll 11 l I111;10•!+) MEA 'Il+1l/ii++ '�'�111ir1ii .. 476-91-EVo113 iNuali 7300-1483: 0174 Overview Standard Features The Booster PowerSupply(MIRBPS)is a UL 864,9th Edition list- • Allows for reliable filtered and regulated power to be installed ed power supply. It is a 24 Vdc filtered-regulated, and supervised where needed unit that can easily be configured to provide additional notification • Cost effective system expansion appliance circuits(NACs)or auxiliary power for Mass Notification/ • Provides for Genesis and Enhanced Integrity notification ap- Emergency Communication(MNEC),as well as life safety, security, and access control applications. pliance synchronization • Supports coded output operation The MIR BPS contains the circuitryto monitor and charge internal • Self restoring overcurrent protection or external batteries. Its steel enclosure has room for up to two 10 ampere-hour batteries. For access control-only applications, • Multiple signal rates the MIRBPScan support batteries totaling up to 65 ampere-hours • Can be cascaded or controlled independently in an external enclosure.The MIR BPS has four Class B(convert- • Easy field configuration ib le to two Class A)NACs.These can be activated in one or two groups from the MIRBPS's unique dual input circuits. • On board diagnostic LEDs identify wiring or internal faults • Standard Kidde keyed lockable steel cab inetwith removable The MIRBPS is available in 6.5 or 10 ampere models.Each output door circuit has a capacity of three amperes;total current draw cannot exceed the unit's rating. • 110 and 230 Vac models available • The MIR BPS meets current UL requirements and is listed under Accommodates 18 to 12 AWG wire sizes the following standards: • Optional tamp erswitch Standard(CCN) Description • Dual battery charging rates UL864 9th edition(UO)()Fire Alarm Systems • Optional earthquake hardening:0 SH P D seismic pre-approval UL636(ANET,UEHX7) Holdup Alarm Units and Systems UL609(AOTX,AOTX7) Local Burglar Alarm Units and Systems for component Importance Factor 1.5 UL294(ALVY,UEHX7) Access Control Systems UL365(APAW,APAW7) Police Station Connected Burglar Alarm Units and Systems UL1076(APOU,APO U7)Proprietary Burglar Alarm System Units UL1610(AMCX) Central Station Alarm Unit ULC-s527(UOXXC) Control Units,Fire Alarm(Canada) ULC-S303(AOTX7) Local Burglar Alarm Units and Systems(Canada) C22.2 No.205 Signaling Equipment(Canada) Page 1 of 4 DATA SHEET K85005-0125 Not to be used for installation purposes. Issue 1 Application Dimensions The MIR BPS provides additional power and circuits for notification appliances and other24 Vdc loads.It is listed for indoor dry loca- 0 0 tions and can easily be installed where needed. y5 0 TopView Fault conditions are indicated on the on-board diagnostic LEDs, opening the MIR BPS input sense circuit and the trouble relay(if + D 2÷ i D 3 programmed).While this provides indication to the host system, _, -� the MIRBPS can still be activated upon command.A separate AC Fail contact is available on the MIR BPS circuit board,which can 04—D 4—*0 be programmed fortrouble or AC Fail.There are seven on-board diagnostic LEDs:one for each NAC fault,one for battery fault,one m ° FrontView for ground fault,and one for AC power. a) ° 73 The unique dual-input activation circuits of the MIRBPS can be activated by any voltage from 6 to 45 VDC(filtered-regulated)or D 1 0 D 6 11 to 33 Vdc(full-wave rectified,unfiltered).The first input circuit O can be configured to activate 1-4 of the four possible outputs.The v: second input circuit can be configured to control circuits 3 and 4. Allknockouts a) When outputs are configured for auxiliary operation,these circuits for3/4 in conduit can be configured to stay on or automatically deactivate 30 sec- o (1.9 cm) ° onds after AC power is lost.This feature makes these circuits ideal o for door holder applications.The MIRBPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation V i t 1 modules. MIRBPS NACs can be configured fora 3-3-3 temporal or continu- D2 D3 D4 D5 D6 ous output.California temporal rate outputs are also available on 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in certain models.This makes the MIRBPS ideal for applications re- (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) quiring signaling rates that are not available from the main system. In addition to the internally generated signal rates,the MIRBPS can also be configured to follow the coded signal rate of the main Wire routing Power-limited system NACs.This allows for the seamless expansion of existing wiring area NACs. The MIR BPS enclosure has mounting brackets for up to three ullr Signature modules to the right of the circuit board. 8 --r J L Engineering Specification — [2] ■ b1 - - 1 Supply,where needed, Kidde MIRBPS Series Booster PowerSup- _ ° plies(MIRBPS)that are interconnected to and supervised by the _ _ main system.The MIR BPS shall function as a stand-alone auxiliary I &—'IQ — • o • power supply with its own fully-supervised battery compliment. •�•o — —[3_1_,_I The MIR BPS battery compliment shall be sized to match the Route AC supply ' IPA ° Iw requirements of the main system.The MIR BPS shall be capable through these11-1 of supervising and charging batteries having the capacity of 24 knockouts only 4 ampere-hours for Mass Notification/Emergency Communication (Nonpower-limited (MNEC),life safety and security applications, and the capacity of and supervised) Battery wiring (nonpower- 65 ampere-hours for access control applications. o limited and supervised) o «The MIRBPS shall be capable of installation fora seismic co m- Battery Battery ponent Importance Factor of 1.5.» The MIR BPS shall provide a minimum of four independent,fully supervised Class B circuits that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits.MIR BPS NACs shall be convertible to a minimum of two Class A NACs.Each MIRBPS output circuit Notes shall be rated at 3 amperes at 24 Vdc.Each output circuit shall 1. Maintain 1/4-inch(6 mm)spacing between power-limited and nonpower-limited be provided with automatically restoring overcurrent protection. wiring or use type FPL,FPLR,orFPLPcable per NEC. [2] Power-limited and supervised when not configured as auxiliary power.Non- The MIRBPS shall be operable from the main system NAC and/or supervised when configured as auxiliary power. Kidde Signature Series control modules.MIR BPS NACs shall be [3] Source must be power-limited.Source determines supervision. configurable for continuous, 3-3-3 temporal or optionally, Califor- 4. When using larger batteries,make sure to position the battery terminals towards nia rate.Fault conditions on the MIR BPS shall not impede opera- the door. tion of main system NAC.The MIRBPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page2of4 DATA SHEET K85005-0125 Not to be used for installation purposes. Issue 1 Typical Wiring Single or cascaded booster NAC Circuit- >To booster,or signaling g NAC Circuit- \ / 1 device,> resistor anywhere on a notification appliance circuit V V EOL resistor ExistingNAC end-of-line resistors are not required to be D 3 >NAC output#1 q Fire Alarm cn 0, >NAC output#2 installed at the booster's terminals.This allows multiple Control Panel >NAC output#3 boosters to be driven from a single NAC circuit without the s s >NAC output#4 need for special configurations. 5. Booster Power Supply Configuring the Booster for Multiple CC1(S) modules using the AC Power Fail delay operation* MIRBPS's sense inputs TB1 Notific ationapplianc e c irc uit(NAC) TB1 Notifica tiona pplia ncecircuit(NAC) NAC1/+ - ©i UL listed NAC1/ + © UL listed AUX1 - (�3j ©� EOL 15 kf2 AUX1 - nJ ©11©1A EOL 15 KW NAC2/ + ® NAC2/ + 44Notificationappliancecircuit(NAC) Notifica tiona pplia ncecircuit(NAC) AUX2 - n AUX2 - pJ NAC3/ + UL listed NAC3/ + a OM UL listed AUX3 - 0I DMZ EOL 15 kf2 AUX3 - ® EOL 15 KW NAC4/ + © NAC4/ + aJ AUX4 - - AUX4 - ©1 200 mAAUX g1 + 200 mAAUX u, Continuous IT n - Continuous m gJ IN ® + IN gJ + Sense 1 COM I n Sense 1 COM I gJ - + EOL 47 K OUT I© ii--,,. OINI© INI�J 1 �OUII INS® + Sense 2 COM I© EOL 47 kf2 109 Sense 2 COM LaiEOL 47 K OUT ® CC1(S)module[1][3] OUT QJ + + NO 0 0 NO a Trouble COM acf 8 7 6 5 4 3 2 1 Trouble COM Q1 lI I 0 I OI".m l NC Imo mg I2221 NC © 109 1 109 TB?) �� +- +-+- TB2 CC1(S) module CC1(S) module o e+Cil+ Datain from Data out to 0 8 7 6 5 4 3 2 1 8 7 6 5 ® 4321 3 2 1 previous device next device aan 41qr module or Signature + � m a-+- [1]a� J+�ta�+— [1] ' ' 2 ' controller I maxum - Datain from previous + *The Booster supports AC Powerfail delay [3] device or Signature Data out to of three hours via its trouble contactwhen controller> next device dip switch SW2-6 is on.All other troubles are reported to supervising module or panel without delay via Sense inputs. Security and access BPS T61 24 V 12 V (( NAC1/ + GO a Security Security EOL AUX1 24DC12 device device monitoring NAC2/+ © device AUX2 - NAC3/+ AUX3 - NAC4/+ ©J AUX4 - ® Control panel BPS[1] Card reader Card reader Card reader controller controller controller + — + — + — + — + — I- 1- To next device [1] Disablethe MIRBPS's ground fault jumper(JP3) or end Page 3 of 4 DATA SHEET K85005-0125 Not to be used for installation purposes. Issue 1 Specifications tib.. KIdde Model 6.5 amp Booster 10 amp Booster ® AC Line Voltage 120VAC or 220-240VAC 50/60Hz 120VAC or 220-240VAC 50/60Hz 390 watts 580 watts Technology that saves lives Notification Appliance 3.0A max.per circuit @ 24Vdc 3.0A max.per circuit @ 24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 10A max total all NACs Contact us... Trouble Relay 2 Amps@ 30Vdc Email:kidde.fire@fs.utc.com AuxiliaryOutputs Four configurable outputs replace NACs 1, 2,3 or4. as auxiliary Web: Kidde.com/EngineeredSystems outputs and 200 mA dedicated auxiliary.(See note 2.) Input Current 3mA @ 12Vdc, 6mA @ 24Vdc Kidde is a UTC brand. (from an existing NAC) 1016 Corporate Park Drive Booster Internal 70mA+35 mA for each circuit set to AUX Mebane,NC 27302 Supervisory Current Booster Internal Alarm 270mA ©2016 United Technologies Corporation. Current All rights reserved. Signature Mounting Accomodates three two-gang modules. Space 10 Amp Hours(2 of 12V10A) in cabinet up to 24 Amp hours with ex- Maximum BatterySize ternal battery cabinet forfire and security applications;up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93%non condensing @ 32°C Temperature Rating 32°to 120°F(0°to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous,California rate,3-3-3 temporal, or follow installed panel's NAC.(See note 1.) Ground Fault Detection Enable or Disablevia jumper Agency Listings UL,ULC,CSFM 1. Model MIRBPS*CAA provides selection for California rate,in place of temporal. 2. Maximum of 8 Amps can be used for auxiliary output. Ordering Information Catalog Number Description Shipping Wt. lb(kg) MIRBPS6A 6.5 Amp Booster PowerSupply 13 (5.9) MIRBPS6AC 6.5 Amp Booster PowerSupply(ULC) 13 (5.9) MIRBPS6A/230 6.5 Amp Booster PowerSupply(220V) 13 (5.9) MIRBPS6CAA 6.5 Amp Booster PowerSupply with California rate 13 (5.9) MIRBPS10A 10 Amp Booster PowerSupply 13 (5.9) MIRBPS1OAC 10 Amp Booster PowerSupply(ULC) 13 (5.9) MIRBPS10A/230 10 Amp Booster PowerSupply(220V) 13 (5.9) MIRBPS1OCAA 10 Amp Booster PowerSupply with California rate 13 (5.9) Related Equipment 12V6A5 7.2 Amp Hour Battery,two required 3.4(1.6) 12V10A 10 Amp Hour Battery,two required 9.5(4.3) 3-TAMP Tamper switch Notes: BC-1 Battery Cabinet(up to 2-40 Amp Hour Batteries) 58(26.4) 1. Requires installation of separate battery BC-2 BatteryCabinet(upto 2-17 Amp Hour Batteries) 19 (8.6) cabinet. BC-1EQ Seismic hardening Kit for BC-1 cabinets. Includes battery hard- 2. MIR BPS supports batteries greater than ening order BC-1 enclosure separately. 24 Amp hours for access control applica- BPSEQ Seismic kit for MIRBPS6Aor MIRBPS10 Booster PowerSup- tio ns only. 3. For earthquake anchorage,including plies.See note 3. detailed mounting weights and center of 12V17A 18 Amp Hour Battery,two required(see note 1) 13 (5.9) gravity detail,please referto Seismic Ap- 12V24A 24 Amp Hour Battery,two required(see note 1) 20(9.07) plication Guide 3101987-EN.Approval of 12V40A 40 Amp Hour Battery,two required(see notes 1, 2) 32(14.5) panel anchorage to site structure may re- 12V50A 50 AmpHour Battery,two required(see notes 1, 2) 40 quire local AHJ,structural,or civil engineerq (18.14) review. 12V65A 65 Amp Hour Battery,two required(see notes 1, 2) 49(22.2) Page4of4 DATA SHEET K85005-0125 Not to be used for installation purposes. Issue 1 Kidde Catalog► Intelligent Initiating hor 0-- 0 Kidde United Technologies Compatible with R O N I C f control systems ADDRESSING Technology that saves lives Intelligent r - ; - . Detectors ~ - and BasesS853/ ...:.......4):2i S 1122 Detectors: V-PS, V-PHS, ), V-HRD Bases: B4U, RB4U, IB4U, SB4U, SB4U-LF li.:,l 7300-1657: 0245-0248 Overview Standard Features Kidde brand intelligent analog detectors are meticulously engi- • Optical,heat,and multisensor models available neered to deliver high-performance features, superb reliability, and • Compatible standard,relay, isolator,and audible bases unbeatable quality.With their highly stable design,these detec- tors resist air movement caused by heating and air conditioning, • Field replaceable optical chamber making them reliable performers ideally suited to modern building • Electronic Addressing including mapping location interiors. • Bases mount to standard North American two-gang or 4" T heinstallation and maintenance advantages of Kidde brand intel- square electrical boxes ligent detectors add value throughout their service life.The twist- and-lock design makes short work of installation and maintenance • Dual color LED provides at-a-glance alarm indication operations.A plastic breakout on the detector housing optionally • Tamper-resistant feature prevents removal from the base except with a special tool. • Self diagnostic capability with on-board storage of results A bright,easy-to-see LED flashes red when the detector is in alarm,thus eliminating much of the guesswork when responding • Optical detectors feature automatic rate compensated sensitiv- to front panel indications. ity adjustment,as well as dirty sensor warnings • The V-HFD is fixed-temperature heat detector with an alarm • Manufactured to strict international ISO 9001 standards threshold of 135° F(57°C). • Assembled using surface mount technology for RF resistance • The V-HRD is a 135°F (57°C) fixed temp with a 15°F (8°C)per • Conformally coated components resist dust and humidity minute rate-of-rise function. • • The V-PHS houses an optical sensing chamber that detects Automatic detector test smoke,as well as a fixed-temperature sensor that detects • Low Profile Design heat.T hedetecto r analyzes data from both sensors to deter- mine when an alarm is initiated. • The V-PS houses an optical sensing chamberthat detects smoke. All detectors feature comprehensive self-diagnostic capability. V-PS and V-PHS optical detectors continuously adjust their sen- sitivity to compensate for changes in the environment such as the presence of dirt,smoke,temperature, and humidity.T hese detec- tors issue a dirty sensor warning when they reach their preset limit. Page 1 of 6 DATA SHEET K85001-0592 Not to be used for installation purposes. Issue 1.1 Heat Detectors Detector Bases T hey-Series heat detectors are capable of performing compre- hensive self-diagnostics and storing the results. < � 4 in.square electrical box - ® j Thanks to advanced thermistor technology,V-Series heat detectors are ideal forsensing fast,flaming fires and for applications where smoke detection is inappropriate.T heyare particularly well-suited to areas such as kitchens and shower rooms,where the ambient relatively r i-��i '`�lig, V 411110-;--- temperature is constant, but where steam and smoke are �� present. ;�!J! i` ' 111 . .,.',; (.,,,-'-ti, V-HRD Rate-of-Rise Heat Detector provides both a 135°F (57°C) " l fixed temp and a 15°F (8°C)per minute rate-of-rise function for the Adaptor bracket detection of heat due to fire. ( ' 117, V-HFD Fixed Temperature Heat Detector provides a 135°F (57°C) 4)� B4U baseassembly fixed-temperature heat sensor for the detection of heat due to fire. Screws T heheat sensor monitors the temperature of the air and deter- mines whether an alarm should be initiated. Trim ring Optical and combination detectors Connect the detectorto the base by rotating the detector clock- wise until it snaps into the locked position. V-Series optical detectors continuously adjust their sensitivity based on fluctuating environmental conditions such as the pres- T he head can be removed by turning it counterclockwise. ence of dirt,smoke,humidity,or changes in temperature, and / a ,6 If the head must lock to the base,break away the notifies the panel of any changes in sensor sensitivity.When the // lockingtab shown below using a pair of pliers. detector has adjusted its sensitivity to its maximum limit, it issues a dirty sensor warning,allowing enough of a margin for maintenance a� To then remove the detector head,insert a small personnel to clean the detector before it goes into trouble condi- 41111 screwdriver into the slot on the side of the base tion. and press in while simultaneously turning the Thesedetectors perform comprehensive self-diagnostics and Breakaway tab detectorhead counterclockwise. store these details in their on-board memory. V-PHS Optical/Fixed Temperature Detector houses an optical B4 U Standard Base sensing chamberthat detects smoke,as well as a fixed-temper- TheB4U Analog Standard Detector Base features twist-and-lock ature sensor that detects heat.Thedetectoranalyzes data from detector installation and is compatible with with V-Series analog both sensors to determine when an alarm is initiated.T his co m detectors.T hebase does not require a separate address because bines the suitability of optical sensing for slow burning fires with it shares the address of the device it is connected to. the sensitivity of fixed-temperature detection for fast flaming fires to arrive at a solution that responds reliably to the widest range ofRemote LED Maximum fire types. resistance .G► per wire A sophisticated algorithm processes data from both sensors over ®0 must not � exceed time so that an alarm is o my reported when conditions precisely 10 Ohms match the signature of a fire.T his eliminates the shortcomings ofF m single-sensor optical and heat detection,and significantly reduces controller 040,1_ , a the risk of nuisance alarms. or fq � previous rO\ O \`\�e To next V-PS Optical Smoke Detector uses an optical sensing chamber device I! /A device to detect smo ke.T hedetector analyzes data gathered by the sen- sLCin( ID SLC out(-) sorto determine when an alarm is initiated. SLCin(+. SIC out(+) Thanksto its high-performance optical sensing chamber,the V-PS Term Description Term Description responds quickly and reliably to a wide range of fire types,espe- 1 SLC in and SLC out(+) 4 Not used cially slow burring fires fuelled by combustibles typically found 2 SLC in(-) 5 Remote LED(+) in modern multi-use buildings.T heV-PS detects extremely small 3 Not used 6 SLC out(-) particles and triggers an alarm at the first sign of smo ke. 3 Not used 6 Remote LED(-) LED Indication V-Series detectors provide a bicolor status LED: • Normal:Green LED flashes • Alarm/active: Red LED flashes Page2of6 DATA SHEET K85001-0592 Not to be used for installation purposes. Issue 1.1 IB4U Isolator Detector Base SB4U/SB4U-LF Audible(Sounder)Detector Bases T he IB4U Analog Isolator Detector Base is designed to prevent SB4U and SB4U-LF sounder bases are designed to add an an entire communications loop from being disabled when a short audible output function to compatible detectors.These bases circuit occurs.T his is accomplished by isolating the part of the can operate as an independent local alarm,or as part of a zone loop containing the short from the remainder of the circuit.T hese or system alarm with synchronized audible output.T heSB4U-LF bases automatically restore the entire loop when the cause of the model provides 520 Hz output suitableforapplications requiring short circuit is corrected. low frequency audib le to nes. SLCin(-) SIC out(-) Depending on the system supporting the device loop,these bases SLCin(+) SIC out(+) From To next can operate as follows: controller III(III device • T heycan follow the state of the device it supports or previous Aiii.II1 • Theycan be controlled and configured for other operating device �', 0 • modes throw h programming. TB � I L:`' g p g g• `° TheSB4U and SB4U-LF are field-configurable for output tone 0 �y ' (steadyortem oral and output volume(lowdBA orhi h dBA). �� /• temporal) p g ) '" Bases must be connected to a continuous voltage whether the U o output tone is set to steady or temporal. Bases do not require separate addresses because they share the address of the de- Term Description vices to which they are connected. SLC in(+) DATA+(IN) SLC in(-) DATA-(IN) SLC out(+) DATA+(OUT) 2 0 SLC out(-) DATA-(OUT) — ®WI® —U— g- 0 o R B4 U Relay Detector Base a o 0 T heRB4U Analog Relay Detector Base is designed to add relay rilsOI I . !IIINI! functionality to the listed compatible detectors. FormC latching AUX_RISER+ A_ir.• A AUX RISER+ relay contacts are included for the control of appliances such as AUX_RISER- . •EAUX_RISER- SLC+ llll ii; SLC+ door closers,fans,dampers,etc. SLC- ii ii; (-)> . SIC out(-) SLCin(+)> SLC out(+) 0 From To next controller1. AUX-RISER IN(from power supply or previous base) or -�� device 2. Volume setting:default is high volume;cut per item 4 for low volume previous ® i � \\ 3. Tone setting:default is temporal pattern;cut per item 4 for steady tone ®I ISI TB2 4. To configure output volumeortone,cut the circuit board as shown rr 11:1 ®I ; ' TB1 5. AUX_RISER OUT To next baseor EO L relay % 1 /> L' 6. SLC OUT to next intelligent addressable device I: O 7. SLC IN from intelligent addressable controller or previous device N/O COM +//C Sleeping rooms:In sleeping areas,the high dBA output and tem- poral tone settings must be used. However, if the FACP is produc- Term Description Term Description ing the three-tone temporal evacuation signal,then the high dBA N/O(Normally open) SLC in(-) DATA-(IN) output and steady tone settings may be used.Some jurisdictions TB1 COM(Common) SLC out(+) DATA+(OUT) require the low frequency output provided by the SB4U-LF. N/C(Normally SLC out(-) DATA-(OUT) Closed) AB4G-SB:When using the AB4G-SB box, SLC in(+) DATA+(IN) Contact rating: install a reinforcinglate at everyknockout r 2.0a CO 30vdc resistive p used. (Reinforcing plates are included with J`r _ ---- Notes the box.)Remove the knockout first,then 1. Wire in accordance with NFPA70,National Electrical Code. slide the reinforcing plate into the plastic 2. Be sure to observe the polarity of the terminals on the terminal block housing.After the plate is in place,install as shown in the diagram. the conduit connector and nut. 3. Breakwire run at each terminal.Do not loop signaling circuit field wires arcundterminals. Page3of6 DATA SHEET K85001-0592 Not to be used for installation purposes. Issue 1.1 Specifications Detectors V-PHS V-PS V-HRD V-HF D Air velocity 0 to 5,000 ft/min(0 to 25.39 m/s) N/A Smoke sensitivity range 0.67%-3.66% ULI fixed-temp alarm rating 135°F(57°C) N/A 135°F(57°C) ULC fixed-temp alarm rating 140°F(60°C) 140°F(60°C) Maximum Spacing 30 ft(9.1 m) 50 ft(15 m)centers Rate-of-Rise N/A 15°F(8°C)/min. N/A Operating voltage 15.2 to 19.95 VDC Normal operating current 45 pA,average Alarm current 45 pA,average Environmental compensation Automatic Compatible bases B4U Standard,RB4U Relay,IB4U Isolator,SB4U Audible Maximum distance from ceiling wall-mounted 12 in(305 mm) Storage temperature -4 to 140°F(-20 to 60°C) Operating Temperature 32 to 100°F(0 to 38°C) 32 to 120°F(0 to 49°C) 32 to 100°F(0 to 38°C) Operating Humidity 0 to 93%RH,noncondensing at 90°F(32°C) Meets UL 268, Meets UL 268, Agency listings ULC-S529-02,UL 521, ULC-S529-02,NFPA72, Meets UL 521, ULC-S530-M91,NFPA72,and ULC-S530-M91, NFPA72, and CAN/ULC S524-01 CAN/ULC S524-01 and CAN/ULC S524-01 Bases B4U Standard Base IB4U Isolator Detector Base RB4U Relay Detector Base Operating environment Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F(32°C) Storage temperature range -4 to 140°F(-20 to 60°C) Compatible detectors V-PS,V-PHS,V-HRD,and V-HFD detectors Compatible electrical boxes North American 2-1/2 in.(64 mm)deep 2 gang box Standard4 in.square box 1-1/2 in.(38 mm)deep box European 100 mm square box Wire size 12, 14, 16, or 18 AWG wire(2.5,1.5, 1.0, or 0.75 sq.mm) (Sizes 16 and 18 AWG are preferred) Base diameter 6.0 in.(152 mm) Height from box(including detector) 2.08 in.(53 mm) 2.57 in.(65 mm) Maximum distance from ceiling(wall 12 in.(305 mm) mount) Sounder Bases SB4U I SB4U-LF(low frequency model) Riser operating voltage 16 to 33 VDC Operating Current See tables above. Supervisory Current DC=1.46 mA DC=6.0 mA Default Output Volume High dBA Default T one Temporal Resonant frequency 3.2 kHz 520 Hz+/-10% Temporal pattern 0.5 son,0.5 s off,0.5 son,0.5 s off,0.5 son,1.5 s off,repeat cycle Compatible detectors Refer to Ordering Information table. Compatible electrical boxes AB4G-SB surface boxforaudiblebase;4 in.squareby2-1/8 in.(54 mm)deep box; 3-1/2 in.octagonal by 2-1/8 in.(54 mm)deep box;Standard European 100 mm2 box Wire size 12 to 18 AWG(0.75 to 2.50 mm2) Base diameter 6.8 in.(173 mm) Base height from box 0.8 in.(21 mm) 1.4 in.(35 mm) Maximum distance from ceiling Wall mount— 12 in.(305 mm) Environment type Indoor only Agency Listings UL,ULC,CSFM UL,CSFM Operating environment Temperature 32 to 120°F(0 to 49°C) Relative humidity 0 to 93%noncondensing Storage temperature -4 to 140°F(-20 to 60°C) Page4of6 DATA SHEET K85001-0592 Not to be used for installation purposes. Issue 1.1 Ordering Information Model Description Ship Wt.:lb.(kg) V-PHS Intelligent Analog Optical/Fixed Temperature Detector 0.25(0.11) V-PS Intelligent Analog Optical Smoke Detector 0.25(0.11) V-HRD Intelligent Analog Rate-of-Rise Heat Detector 0.25(0.11) V-HFD Intelligent Analog Fixed Temperature Heat Detector 0.25(0.11) B4U Standard Base 0.11 (0.05) RB4U Relay Detector Base 0.11 (0.05) IB4U Isolator Detector Base 0.11 (0.05) SB4U Audible(Sounder)Detector Base 0.11 (0.05) SB4U-LF Audible(Sounder)Detector Base,Low Frequency Output 0.11 (0.05) AB4G-SB Surface Box for Audible Base 1.0(0.45) GSA-LED Remote alarm LED,use with standard baseonly 0.2(.09) 211-10PKG Replacement optical chambers(package of 10) 0.25(0.11) Page5of6 DATA SHEET K85001-0592 Not to be used for installation purposes. Issue 1.1 ilk Kidde Technology that saves lives Contact us... Email:kidde.fire@fs.utc.com Web: Kidde.com/EngineeredSystems Kidde is a UTC brand. 1016 Corporate Park Drive Mebane,NC 27302 ©2017 United Technologies Corporation. All rights reserved. rn Page6of6 DATA SHEET K85001-0592 Not to be used for installation purposes. Issue 1.1 Kidde Catalog► Intelligent Initiating 4,r 0-- 0 Kicicle United Technologies ELECTRONIC ' Compatible with V M control systems ADDRESSING Technology that saves lives / Manual Pull Stations {PULLCS OF LIFT THEN FIRE GSA-M270, GSA-M270PPULL HANDLE ; , - GSA-M278 FIRE ‘lor_Kidde GSA-M270 SERIES • [Kidde ow= UL GSA-M278 iii 1112* 6 7150-1483: M 0139 EA S2318 Overview • Break glass operation An up-front visible glass rod on the GSA-M270 discourages The GSA-M270 and GSA-M278 series Manual Pull Stations are tampering. part of Kidde's Signature Series system.The GSA-M270 Fire Alarm Manual Pull Stations feature our very familiar teardrop • Intelligent devicewith integral microprocessor shape.They are made from die-cast zinc and finished with red All decisions are made at the station allowing lower co m- epoxy powder-coat paint complemented by aluminum colored munication speed while substantially improving control panel stripes and markings. With positive pull-lever operation, one pull response time. Less sensitive to line noise and loop wiring on the station handle breaks the glass rod and turns in a posi- properties;twisted or shielded wire is not required. tive alarm,ensuring protection plus fool-proof operation. Presignal • ADA Compliant models(GSA-M270P)are equipped with a general alarm(GA) Meets ADA requirements for manual pull stations. keyswitch for applications where two stage operation is required. The up-front highly visible glass rod discourages tampering, but is • Electronic Addressing with Non-volatile memory not required for proper operation. Permanently stores programmable address,serial number, type of device,and job number.Automatically updates historic Kidde's double action single stage GSA-M278 station is a contem- information including ho urs of operation, last maintenance porary style manual station made from durable red colored lexan. date,number of alarms and troubles,and time and date of last To initiate an alarm,first lift the upper door marked"LIFTTHEN alarm. PULL HANDLE",then pull the alarm handle. • Automatic devicemapping Each station transmits wiring information to the loop control- Standard Features ler regarding its location with respect to other devices on the Note:Some features described here may not be supported by all control sys- circuit. tems.Check your control panel's Installation and Operation Guide for details. • Stand-alone operation • Traditional familiar appearance The station inputs an alarm even if the loop controller's polling GSA-M270 models feature our familiar teardrop design with interrogation stops. simple positive pull action and sturdy die-cast metal body. • Diagnostic LEDs • One stage(GA),two stage(pre-signal),and double action Status LEDs;flashing GREEN shows normal polling;flashing models RED shows alarm state. GSA-M270 models are available for one or two stage alarm • Designed for high ambient temperature operation systems.The single stage double action GSA-M278 features a Install in ambient temperatures up to 120 °F(49°C). rugged Lexan housing with keyed reset mechanism. Page 1 of 4 DATA S H E El K85001-0279 Not to be used for installation purposes. Issue 1 Application Typical Wiring The operating characteristics of the fire alarm stations are deter- The fire alarm station's terminal block accepts#18 AWG(0.75mr6) mined by their sub-type code or"Personality Code".NORMALLY- to#12 AWG(2.5mm2)wire sizes.See Signature Loop Controller OPEN ALARM-LATCHING(Pesonality Code 1)is assigned by the catalog sheet fordetailed wiring requirement specifications. factory; no user configuration is required.The device is configured forClass B IDC operation.An ALARM signal is sent to the loop Wiring Notes controller when the station's pull lever is operated.The alarm con- ARefer to Signature Loop Controller manual for maximum dition is latched at the station. wire distance. 2. All wiring is power limited and supervised. Compatibility REAR VIEW of 278 Signature Series manual stations are compatible only with Kidde's Signature Loop Controller. p TB2 i Warnings& Cautions 7 This device will not operate without electrical power.As fires fre- Redquently cause power interruption,we suggest you discuss further (Ala m/ActItive) o o G(NNororreeLED mal) safeguards with your local fire protection specialist. 3 2 ' O Tel II UI UI 11 1I.i Testing & Maintenance -�■IU� To test(orreset)the station simply open the station and operateDATA IN(+) (+)DATA OUT the exposed switch.The GSA-M270 series are opened with a tool; {DATA IN(-) DATA OUT(-) the GSA-M278 requires the key which is supplied with that station. From Signature Controller To Next Device or Previous Device 0 The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message.The user-friendly maintenance Figure 4. Single Stage Systems program shows the current state of each Signature series device and other pertinent messages.Single devices may be deactivated temporarily,from the control panel.Availability of maintenance features is dependent on the fire alarm system used. REARofVIEW Scheduled maintenance(Regular or Selected)for proper system 270P,270PB operation should be planned to meet the requirements of the Authority Having Jurisdiction(AHJ).Refer to current NFPA72 and ° ULC CAN/ULC 536 standards. TB2 I0 8 7 6 5 Red LED Oo Green LED (Alarm/Active) I 4 3 2 (Normal) TB] 1101111. h O �I (DATA IN(+) DATA OUT(+)1 1 DATA IN(-) DATA OUT(-)1 From Signature Controller To Next Device or Previous Device Figure 5. Two Stage Systems Page 2 of 4 DATA SHEET K85001-0279 Not to be used for installation purposes. Issue 1 Installation Single-stage Signature Series fire alarm manual pull stations ma unt to North American 21/2 inch(64 mm)deep 1-gang boxes. Two stage presignal(270P)models require 11/2 inch(38 mm)deep 4-inch square boxes with 1-gang, 1/2-inch raised covers. Openings must be angular.Rounded openings are not acceptable.Recommended box:Steel City Model 52-C-13; in Canada,use Iberville Model CI- 52-C-49-1/2. All models include terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size.Kidde recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. ElectronicAddressing: The loop controller electronically addresses each manual station,saving valuable time during system com- missio ning.Setting complicated switches or dials is not required.Each station has its own unique serial number stored in its on-board memory.The loop controller identifies each device o n the loop and assigns a"soft"address to each serial number. If desired,the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. Key-Latch Compatible Electrical Box m IFCompatible Electrical Box •Cover Release Cover t�r� �j/ I IA4 ,,, Release `� Screw 0511 As ;ill O pii /' O m \ 9�0 ® ° �lYit Back I ° Back 0 1Q Plate 0 Plate �� II" /\ n Toggle Toggle Cr; ° Switch O ip ° • Switch 0 07:v Rrd� �� I . NORMA jGlass Rod tI Glass Rod 11 II'I 1 Release Lever 11111 s, OPEN • : '&PIW '',qb ,,, • Figure 1. GSA-M278 installation Figure 2. GSA-M270 installation Cover Release Scr-w 401101„):0 \ Compatible ElectricalwitBox • with 1/2-inch !r5)raised covers il► `- Q ° lillo o �• Back Plate ))1 ) ' l Toggle J �i ° Switch (lio' 1 NORMAL 0.1, o O ,-3, Glass Rod Release Lever Do not use boxes with openings. kHillf,111 , openings. Figure 3. GSA-M270P installation Page3of4 DATA SHEET K85001-0279 Not to be used for installation purposes. Issue 1 Specifications ��1. Kidde Catalog Number GSA-M270 GSA-M270P, GSA-M278 ® Description Single Action Single Action-Two Double Action - One Stage Stage(Presignal) -One Stage Technology that saves lives Addressing Uses 1 Module Uses 2 Module Uses 1 Module Requirements Address Addresses Address Contact us... Operating Current Standby=250pA Standby=396pA Standby=250pA Email:kidde.fire@fs.utc.com Activated=400pA Activated=6801A Activated=400pA Web: Kidde.com/EngineeredSystems Diecast Zinc-Red Epoxy Lexan-Red with Construction&Finish with aluminum markings white markings Kidde is a UTC brand. Type Code Factory Set 1016 Corporate Park Drive Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Mebane,NC 27302 Operating Temperature:32°Fto 120°F(0°Cto 49°C) Storage and Operating Storage Temperature:-4°F to 140°F(-20°C to 60°C)Humidity:0 to 93% ©2016 United Technologies Corporation. Environment RH All rights reserved. LED Operation On-board Green LED-Flashes when polled On-board Red LED-Flashesw hen in alarm Compatibility Use With:Signature Loop Controller Agency Listings UL,ULC,MEA,CSFM,FM Ordering Information Ship Catalog Wt.lbs Number Description (kg) GSA M270 One Stage Fire Alarm Station, English Markings -UUULC Listed GSA-M270P Two Stage(Presignal)Fire Alarm Station,English Markings 1 (0.5) -UUULC Listed GSA M278 Double Action(One Stage)Fire Alarm Station,English Markings -UUULC Listed Accessories 270-GLR 20 Glass Rods-for GSA-M270 series (USA ONLY) 276-GLR 20 Glass Rods-forGSA-M278 series 0 Page 4 of 4 DATA SHEET K85001-0279 0 Not to be used for installation purposes. Issue 1 Kidde CatalogIntelligent Input-Output 4,r 0-- 0 Kidde E L E C T '] United Technologies Compatible with V VM control systems ADDRESSING Technology that saves lives ii. ill Input Mo Jules ' GSA-CT1 , GSA-CT1HT, Ilii ', GSA-MCT2 17 ,:: 1 MEA Fg ( sidilll imjl i 1 B i 7300-1483: 0115 ?t,,,' GSA-CT1/2 O .,� ll� GSA-MCT2 0 S3424 Overview Standard Features The GSA-CT1 Single Input Module,GSA-CT1HT High Tempera- • Multiple applications ture Single Input Module and GSA-CT2/GSA-MCT2 Dual Input Including Alarm,Alarm with delayed latching(retard)for water- Modules are intelligent analog addressable devices used to con- flow applications,Supervisory, and Monitor.The installer selects nect one or two Class B normally-open Alarm,Supervisory, or one of four"personality codes"to be downloaded to the mod- Monitortype dry contact Initiating Device Circuits(IDC). ule through the loop controller. The actual function of these modules is determined by the"personal- • GSA-CT1HT rated for high temperature environments ity code"selected by the installer.This code is downloaded to the Suitable forattic installation and monitoring high temperature module from the Signature loop controller during system configura- heat detectors. tion. • Plug-in(UIO)or standard 1-gang mount The input modules gather analog information from the initiating UIO versions allow quick installation where multiple modules are devices connected to them and convert it into digital signals. required.The 1-gang mount version is ideal for remote loca The module's on-board microprocessor analyzes the signal and tions that require a single module. decides whether or not to input an alarm. • Automatic device mapping Signature modules transmit information to the loop controller The GSA-CT1,GSA-CT1HT and GSA-CT2 mount to standard regarding their circuit locations with respect to other Signature North American 1-gang electrical boxes,making them ideal for lo- devices on the wire loop. cations where only one module is required.Separate I/Oand data • Electronic addressing loop connectionsare made to each module. Programmable addresses are downloaded from the loop con- The GSA-CT1HT module operates at an expanded temperature troller,a PC,or the Signature Program/Service Tool.There are range of 32°F to 158 °F(0°C to 70°C)for those applications no switches or dials to set. requiring more extreme environmental temperature variation. • Groundfault detectionby address The GSA-MCT2 is part of the UlO family of plug-in Signature Detects ground faults right down to the device level. Series modules.It functions identically to the GSA-CT2,but takes advantage of the modular flexibility and easy installation that characterizes all UlO modules.Two-and six-module UlO mother- boards are available.All wiring connections are made to terminal blocks on the motherboard. UlO assemblies may be mounted in Kidde enclosures. Page 1 of 4 DATA SH E El K85001-0241 Not to be used for installation purposes. Issue 1 Signature Series Overview _,IO Motherboard The Signature Series intelligent analog-addressable system from 1 6-32 9 9 g- Y Self-tapping Kidde Security is an entire family of multi-sensor detectors and screws mounting bases,multiple-function input and output modules, -- _ r — —� network and non-network control panels,and user-friendly mainte Plug-in(44 `i.Captive nance and service tools.Analog information from equipment con- Module screws nected to Signature devices is gathered and converted into digital -- {1—.4 signals.An onboard microprocessor in each Signature device _ _ measures and analyzes the signal and decides whether or not to � =um..Flat washers input an alarm.The microprocessor in each Signature device pro- videsfouradditionalbenefits—Self-diagnostics and History Log, _ Cabinet or electrical enclosu re Automatic Device Mapping,and Fast,Stable Communication. Self-diagnostic sand History Log—Each Signature Series Electronic Addressing-The loop controller electronically ad- device constantly runs self-checks to provide important mainte- dresses each module,saving valuable time during system co m- nance information.The results of the self-check are automatically missioning.Setting complicated switches or dials is not required. updated and permanently stored in its non-volatile memory.This Each module has its own unique serial number stored in its information is accessible for review any time at the control panel, on-board memory.The loop controller identifies each device on PC,or using the Signature Program/Service Tool. the loop and assigns a"soft"address to each serial number. If Automatic Device Mapping—The Signature Data Control- desired,the modules can be addressed using the Signature Pro- ler(SDC)learns where each device's serial number address is gram/Service Tool. installed relative to other devices on the circuit.The SDC keeps a Kidde recommends that this module be installed according to lat- map of all Signature Series devices connected to it.The Signature est recognized edition of national and local fire alarm codes. Series Data Entry Program also uses the mapping feature.With interactive menus and graphic support,the wired circuits be- tween each device can be examined.Layout or"as-built"drawing Application information showing branch wiring(T-taps), device types and their address are stored on disk for printing hard copy. The duty performed by the GSA-CT1 and GSA-CT2/MCT2 is de- termined by their sub-type code or"Personality Code".The code is selected by the installer depending uponthe desired application Installation and is downloaded from the loop controller. GSA-CT1,GSA-CT1HT and GSA-CT2:modules mount to North One personality code can be assigned to the GSA-CT1.Two per- American 21/2 inch(64 mm)deep 1-gang boxes and 11/2 inch(38 sonality codes can be assigned to the GSA-CT2/MCT2. Codes mm)deep 4 inch square boxes with 1-gang covers and GSA-MP 1, 2,3 and 4 can be mixed on GSA-CT2/MCT2 modules only.For mounting plates.The terminals are suited for#12 to#18 AWG(2.5 example, personality code 1 can be assigned to the first address mm2 to 0.75 m tiliNn"ire size. (circuit A)and code 4 can be assigned to the second address Compatible electrical box (circuit B). 2'11 NORMALLY-OPEN ALARM -LATCHING (Personality Code 1) -Assign to one or both circuits. Configures either circuit A or B or 1 both for Class B normally open dry contact initiating devices such r I + � as Pull Stations,Heat Detectors, etc.An ALARM signal is sent to l�` Wall plate,white the loop controller when the input contact is closed.The alarm /)i,11/�. (1-gang) condition is latched at the module. � �41101 NORMALLY-OPEN ALARM -DELAYED LATCHING (Person- I ality Code 2)-Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- �I��� G? ing devices such as Waterflow Alarm Switches.An ALARM signal MSo. M., is sent to the loop controller when the input contact is closed for Status LEDsapproximately 16 seconds.The alarm condition is latched at the Gsmodule. LED viewing ports • " NORMALLY-OPEN ACTIVE- NON-LATCHING (Personality 0\ 's , Code 3)-Assign to one or both circuits.Configures either circuit �y CI A or B or both for Class B normally-open dry contact monitoring input such as from Fans,Dampers, Doors,etc.An ACTIVE signal GSA-MCT2:mount the UIO motherboard inside a suitable Kidde is sent to the loop controller when the input contact is closed.The enclosure with screws and washers provided. Plug the GSA- active condition is not latched at the module. MCT2 into any available position on the motherboard and secure NORMALLY-OPEN ACTIVE- LATCHING (Personality Code the module to the motherboard with the captive screws.Wiring 4)-Assign to one or both circuits. Configures either circuit A or co nnectio nsare made to the terminals on the motherboard(see B or both for Class B normally open dry contact monitoring input wiring diagram).UIO motherboard terminals are suited for#12 to such as from Supervisory and Tamper Switches.An ACTIVE signal #18 AWG(2.5 mm2 to 0.75 mm2)wire size. is sent to the loop controller when the input contact is closed.The active condition is latched at the module. Page2of4 DATA SHEET K85001-0241 Not to be used for install Issue 1 Typical Wiring Modules will accept#18 AWG(0.75mm2),#16 (1.0mm2), and#14AWG(1.50mm2), and#12 AWG(2.50mm2)wire sizes. Note:Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation.See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave)Devic eCirc uitWire Specifications Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit Maximum Allowable Wire Capacitance 0.lpF per Circuit For Design Reference: Wire Size Maximum Distanceto EOLR #18 AWG(0.75 mm2) #16 AWG(1.00 mm2) 4,000 ft(1,219 m) #14 AWG(1.50 mm2) #12 AWG(1.50 mm2) Typical N.O.Initiating Device Typical N.O.Initiating Device WJINPUT 1 INPUT 2 ith HH Wain A&A Q4 Style B(Class B) /-II0 ,.=:. TB2 I®® TB2 I I I I. 8 7 UL/ULC Listed S le B Class B • • • 471x1 EOL UL/ULC 2 List d IAA 8 a s UL/ULC Listed • • • 47KII EOL Red LEDe� Green LED (Alarm/Active) (Normal) Red LED Oo �, Green LED 3 2 1 I (Alarm/Active) 4 32 i`". (Normal) TBI ®®TT� T13111=1( .1 DATA IN(+) I ►DATA OUT(+) j(DATA IN(+) ' DATA OUT(+) l DATA IN(-) 0..DATA OUT(-) l DATA IN(-) DATA OUT(-) To Next Device From Signature Controller To Next Device From Signature Controller or Previous Device or Previous Device A 3 GSA-CT 1, GSA-CT 1HT GSA-CT2 ♦ 1 1 Typica 1NO Initiating Device1 I NOTES UL/ULC uLieted +I 1 1 HD Input 2 Fran UL/ULC Listed 47KW EOL 47KW EOL AMaximum 25 Ohm resistance per wire. A Maximum#12 AWG(2.5 mm2)wire;Minimum#18 AWG(0.75 mm2). A©A AReferto Signature controller installation sheet for wiring specifications. /w\Maximum 10 Vdc @ 350 pA MCT2 AThe GSA-ulo6R and the GSA-UIO2R do not come with TB14. 2 a 4A UIOIRIseries motherboa rd I,79' r 6 All wiring is supervised and power-limited. "1"_ IT Datalo Q7 These modules will not support2-wire smoke detectors. ISSignature No connections required for 7 Data ■ ■ MCT2 Circuit0..Othermodules ma yrequire Da taOut+Warnings& CautionsGreen rma Ii This module will not operate without electrical power.As fires fre- RedLED(ALEDOctvel quently cause power interruption,we suggest you discuss further safeguards with your local fire protection specialist. No connections or jumper settings required for MCT2. Compatibility GSA-MCT2 These modules are part of Kidde's Signature Series intelligent pro- cessing and control platform.They are compatible with VM,and VS Series control panels. Page 3 of 4 DATA SHE El K85001-0241 Not to be used for installation purposes. Issue 1 Specifications �,I, Kidde Catalog Number GSA-CT1HT I GSA-CT1 GSA-CT2 I GSA-MCT2 ® Description Single Input Module Dual Input Module Type Code 48(factory set)Four sub-types 49(factory set)Four sub-types Technology that saves lives (personality co des)are available (personality co des)are available Address Requirements Uses One Module Address Uses Two Module Addresses Contact us... Operating Current Standby=250pA; Standby=396pA; Email:kidde.fire@fs.utc.com Activated=400pA Activated=680pA Web: Kidde.com/EngineeredSystems Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Construction High Impact Engineering Polymer Kidde is a UTC brand. Mounting North American 21 inch(64 mm)deep one-gang box- UIO2R/6R/6 1016 Corporate Park Drive Mebane,NC 27302 es and 11/2 inch (38 mm)deep 4 inch square boxes Motherboard with one-gang covers and GSA-MP mounting plates ©2016 United Technologies Corporation. Operating Environment 32°F to 158°F 32°F to 120°F(0°C to 49°C) All rights reserved. (0°C to 70°C) Storage Environment -4°F to 140°F(-20°C to 60°C);Humidity:0 to 93%RH LED Operation On-board Green LED-Flashes when polled;On-board Red LED- Flashes when in alarm/active. Both LEDs-Glow steady when in alarm Compatibility Use with Signature Loop Controller Agency Listings UL,ULC,MEA,CSFM Ordering Information Catalog Description Ship Wt. Number lbs(kg) GSA-CT1 Single Input Module— UL/ULC Listed 0.4(0.15) GSA-CT1HT Single Input Module High Teperature Operation UL/ULC Listed 0.4(0.15) GSA-CT2 Dual Input Module— UL/ULC Listed 0.4(0.15) GSA-MCT2 Dual Input Plug-in(UIO)Module — UL,ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box-Red,1-gang 1.0 (0.6) 27193-16 Surface Mount Box-White,1-gang 1.0 (0.6) GSA-U102R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) —Two Module Positions GSA-U106R Universal Input-Output Module Board w/Riser Inputs 0.62(0.28) —Six Module Positions GSA-UIO6 Universal Input-Output Module Board —Six Module Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet— Red,supports Signature Module 7,0(3.1) Mounting Plates GSA-MB4 Transponder Mounting Bracket(allows for mounting 0.4(0.15) two 1-gang modules in a 2-gang box) GSA-MP1 Signature Module Mounting Plate,1 footprint 1.5 (0.70) GSA-MP2 Signature Module Mounting Plate,1/2 footprint 0.5(0.23) GSA-MP2L Signature Module Mounting Plate,1/2 extended footprint 1.02 (0.46) Page 4 of 4 DATA SHEET K85001-0241 a Not to be used for installation purposes. Issue 1 Kidde Catalog►Strobes,Horns,Bells,Chimes 4,r-- 0 Kidde United Technologies IIr Technology that saves lives f I F .. I..... j \j'\,I F:: i' euenc a y )7711)711,1111f 1,1,13 11111,,.■rrrr+ls11111 520 1)111]arrl■.N/1 s,11, Hz 7111rrr■rrrrlrrr.11s, AudibleSignals �� � 11+....lrrrrrl...•os1 slrarrrrrr.■.ar///.,3 i�i�� ii��r+iiii�* , Genesis G4LF Series j1r, .r.1r/rrrrr 11r■r.rrr■s■r.. .a1• ' „1.■■rr••..■...1.71,▪ 1 11171.••/•/.++•11113 111111• .r/a1111,1111 S218 ■91 ))1),11'11 • Hz Overview Standard Features G4LF Series notification appliances provide the benefits of Gen- • Unique low-profile design... esis life safety signals with output suitable for applications requiring - Compact UL listed audible and audible-visible appliances low frequency audib le tones.These high-performance appliances - Ultra-slim:protrudes an inch from the mounting surface generatea crisp 520 Hz tone in the standard3-3temporal pat- - Attractive appearance: no visible mounting screws tern.An optional setting configuresthe appliance for continuous • Choice of colors and markings... audible output — a critical feature for notification appliance circuits - White or red housings that are coded with a CDR-3coder module.G4LF appliances also - With or without FIRE markings feature field-configurable high and low dB output settings. • Easyto install... When connectedto compatible control equipment,G4LF Series - Room side wiring accepts#18 -#12 AWG(0.75 to 2.5 mm2) audible output remains synchronized with all Genesis audible sig- - Fits standard 4-inch square electrical boxes or standard nals on the same Notification Appliance Circuit,including standard Gensis EG4B or EG4RB surface-mount boxes 3.2 kHz Genesis audible signals. • Easyto configure without removing the device... Available G4LF models include audible-onlyappliances, as well - High or low dB output as combination audible-visible signals.Combination appliances - Temporal or continuous audible tone feature Genesis FullLight""strobe technology,which produces - Temporal or continuous visibleoutput a smooth light distribution pattern without the spikes and voids - 15, 30, 75,or 110 candela intensity that characterize bulky specular reflectors.This ensures the entire coverage area receives consistent illumination exceeding UL-1971 • High performance output... light distribution requirements. It also results in a slim, low profile - Exclusive FullLightT"strobe output distribution pattern device that blends with any decor. Candela output is field co nfigu- - Meets tough synchronization standards for strobes rable. and audible signals When connectedto a compatible synchronization source, Genesis appliances synchronize(strobes to UL 1971) to within 10 millisec- onds indefinitely without the need for external modules or other equipment.See the Specifications section fora list of synchroniza- tion sources. Page 1 of 4 DATA S HE El K85001-0639 Not to be used for installation purposes. Issue 1 Application Installation Genesis G4LF Series appliances are UL 464-listed for low-fre- Genesis G4LF Series appliances mount to a standard 4 inch(102 quency audible requirements. Models are also available in comb i- mm)square electrical boxusing the provided mounting spacer or nation with a UL 1971-listed strobe light for indoor wall-mounted directly to a Genesis G4 surface mount box. public-modenotification applications. Many codes and regulations now call for low-frequency audible appliances(520 Hz)in newly All Genesis appliances have two tabs at the top of the signal. constructed sleeping rooms and also require strobe lights under Unlock the coverto reveal the mounting hardware.The shallow some of these circumstances. Consult with your Authority Having depth of Genesis devices leaves ample room behind the signal for Jurisdiction for details. extra wiring.Once installed with the cover in place,no mounting screws are visible. Combination audible-visible appliances are installed in accordance with guidelines established for visible(strobe)devices. Oo Flush Mounting i When used with a compatible synchronization source, all Genesis t' xenon-based strobes — audible units,and combination appli- ances— maintain fully synchronization indefinitely.This exceeds c>f - ,,,,°,,, the UL synchronization requirements of 10 milliseconds overa two-hour period. r � Compatible �.i-' electrical box WARNING:Thesedevices will not o eratewithoutelectricalpower.As 1 litit�i� p �% i firesfrequentlycausepowerinterruptions,wesuggestyoudiscussfurther ;; II\? .i4it safeguards with your local fire protection specialist. �', ; d .I II Flush mount M ot,° �!ii1 spacer(supplied) Kidde recommends that these devices always be installed in ac- 101111...i °a g=e ��. cordance with the latest recognized edition of national and local . I°o g aloe G4LF codes.Referto the appropriate codes and standardsformounting o height information. p► �.li Housing Audible Signal Application Surface Mounting Noe. Genesis low-frequency audible output features a code-compliant -' 14► 520 Hz signal.Audible signals may be co nfigured fo r either coded or non-codedsignal circuits.They can also be set for low dB out- IIS'. put with a jumper cut that reduces audible output by about5 dB. - - ,''Itic<' Audible-only models may be ceiling-mo untedor wall-mounted. .� EG4B or EG4RB �, ° I�\ Surface Mount For sleep ing rooms,most codes and standards require 75 dBA �' ..Ijl.l� I Box fast at the pillow. \� '�i • Po t III ,a For non-sleep ingooms,the suggested sound pressure level41114.;: � 4$ 8 G4LF for each signaling zone used with alarm signals is at least 15 dBl,°,.t .; F above the average ambient sound level,or 5 dB above the maxi- o, � I mum sound level having a duration of at least 60 seconds,which- ®°°'`` E ever is greater.This is measured 5 feet(1.5 m)above the floor. Housing Doubling the distance from the signal to the ear will theoretically result in a 6 dB reduction of the received sound pressure level. Typical Wiring The actual effect depends on the acoustic properties of materials yp in the space.A 3 dBA difference represents a barely noticeable Room-sidefield wiring terminals accommodate#18 to#12 AWG change in volume. (0.75 mm2 to 2.5 mm2)wiring.Audible appliances, strobes, and combination audible-visual appliances are interconnected with a single pair of wires as shown. Visible Signal Application poR / IFi For sleeping rooms covered by NFPA, a strobe light is typically re- quired within 16 feet of the pillow.If the strobe light is wall-mount- From NAC v O ed and at orfartherthan 24 inches(610 mm)from the ceiling,it output / should be 110 cd or greater. If the strobe light is ceiling-mounted - . ` orwall-mountedcloserthan 24 inches(610 mm)to the ceiling,it + must be 177 cd or greater. To next device or EOL ' W° •vz J = -4 d .0A1 From NAC ., output Q:.c . -III°E ' - Note:Polarity is shown in the active condition. II IIIIIIII IIIIIIII Page 2 of 4 DATA SHEET K85001-0639 Not to be used for installation purposes. Issue 1 Field Configuration Light Output Genesis G4LF Series audible appliances are factory set to oper- Per cent of UL rating versus angle ate in a Temporal 3(three-pulse)pattern. Units may be configured for use with coded systems by cutting jumperJP2 on the circuit %�"8etl`a�sp -%Of Cantlela V Spec. ° board.This results in a steady output that can be turned on and30.15-,° -5 5 1015 z0 off(coded)as the system applies and removes power to the signal -35 20 30 -35 35 circuit.A Genesis Signal Master is required to maintain G4LF 45-40 00 45 strobe light synchronization when connected to a coded system. 50 �,, 50 -6055 ' 5560 • Audible signals and combination audible-visible appliances are -66 65 factory set for high dB output. Low dB output may be selected by ' '° -75 \ , ]5 cutting jumper JP3 on the circuit board.This reduces the output \ 50 byabout5 dB. -65 �1 3 65 -90 1 1 00 Genesis G4LF Series strobe lights are shipped from the fac- m m W Minium UL required candela output SP.rW tory ready for use as UL 1971 compliant signals for public mode operation.These signals may be configured for temporal flash by cutting jumper JP1 on the circuit board.This battery-saving Current Draw feature may be used for private mode signaling only. Audible Visible Appliances D�� �a Operating horn-strobe current in RMS(mA) with audible set to standard(high)output ® O x Strobe 15 30 75 110 JP3 Audible .° ",, output(cd) dB Output: JP3 =. • d ,f Temporal cut for low. a JP2Audible . "i 16 VDC 219 266 381 437 pattern:cut\ c-C\ : s 16 VFWR 308 362 510 579 forsteady. O i- _ �` 24 VDC 151 176 243 278 y .� ° patrn:obecut JP1 at.._- !_,..1. Jg 24 VFWR 228 258 349 395 pattern:cut JP2 -'6 i. fortemporal i— t 33 VDC 112 132 177 199 (private ���� mode only). - --i, 33 VFWR 186 208 267 291 f j Continuous ( 16 VDC 221 258 371 433 Candela switch and indicator—�Jro_ __w — 16 VFWR 305 358 514 576 L 24 VDC 147 171 239 274 Genesis G4LF Series strobe lights may be set for 15, 30,75, or 24 VFWR 211 247 335 377 110 candela output.The output setting is changed by simply 33 VDC 110 179 175 196 opening the device and sliding the switch to the desired setting. 33 VFWR 178 199 257 282 The appliance does not have to be removed to change the output VDC=Volts direct current,regulated and filtered setting.The setting remains visiblethro ugh a small window on the VFWR=Volts full wave rectified side of the device after the cover is closed. Operating Current No minal Sound Level Output RMS(mA)Audible appliance only Signal and voltage Low High UL(dBA) UL 464:Sound Temporal 16 VDC 86 166 Signal and voltage Low High level outp utat 10 ft.(3.05 m) 24 VDC 43 112 Temporal 16 VDC 72.4 76.0 measured in a 33 VDC 36 87 24 VDC 72.3 75.7reverberant room. 16 VFWR 97 215 33 VDC 73.3 75.4 24 VFWR 78 159 Continuous 16 VDC 75.7 79.8 33 VFWR 76 140 24 VDC 76.1 78.6 Continuous 16 VDC 36 160 33 VDC 75.4 78.8 24 VDC _ 45 109 33 VDC 36 86 16 VFWR 92 212 24 VFWR 80 168 33 VFWR 77 141 VDC=Volts direct current,regulated and filtered VFWR=Volts full wave rectified Page 3 of 4 DATA S H E E l K85001-0639 Not to be used for installation purposes. Issue 1 — — Specifications 1(i d d e Genesis G4LF Audible and Visible Signals Operating voltage 24 VDC or 24 VFWR[1] Housing Red or white textured UV stabilized,color impregnated engineered plastic. Technology that saves lives Dimensions Height:6.5"(165 mm).Width:5"(127 mm).Depthto wall:1" (25 mm). Mounting Flush:North-American 4"square box,2 1/8"(54 mm)deep.Requires Contact us... (indoor wall mount supplied spacer. only) Surface:model EG4B(white)or EG4RB(red)surface mount box. Email:kidde.fire@fs.utc.com FACPs:VM and VS Series life safety systems,FX Series fire alarm control Web: Kidde.com/EngineeredSystems Synchronization panels.Moduels:GSA-CC1S,GSA-MCC1S,SIGA-CC2A,GSA-MCC2A, Sources EG1M-RM.Powersupplies:MIRBPS6A, MIRBPS10A,APS6A,APS10A. Kidde is a UTC brand. Wire Size 12 to 18 AWG(0.75 to 2.50 mm2). 1016 Corporate Park Drive Mebane,NC 27302 Operating 32-120°F(0-49°C)ambienttemperature;0-93%relative humidity, environment noncondensing. ©2016 United Technologies Corporation. All rights reserved. Audible Signal Audible pulse rate Temporal rate with compatible synchronization source:indefinitely within 10 milliseconds. Temporal audible 1/2 sec ON,' sec OFF,' sec ON,1/2 sec OFF,' sec ON,11 sec OFF, pattern then repeat cycle. Visible Signal Strobe Output Rating UL 1971: selectable 15 cd,30 cd,75 cd,or 110 cd output Strobe Operating 16 -33 Vdc Regulated,16-33 V Full wave rectified(UL Voltage Voltage Designations"Regulated 24"and"24 fwr") Strobe Flash Rate One flash per second. One flash persecond(fps)within 10 milliseconds over a 2 hour time Strobe Flash period on a common circuit.Synchronization source required to comply Synchronization with UL 1971 synchronization standard.Temporal setting(private mode only):synchronized to temporal output on the same circuit. Strobe Lens Material Polycarbonate [1]This device was tested to the Regulated 24 DC/FWR operating voltage limits of 16 V and 33 V.Do not apply 80%and 110% of these values for system operation. Ordering Information Audible Visible Ship Wt. Model Housing Marking Signal I Signal I lbs(kg) Fire Alarm Appliances(520 Hz screen printed on housing) G4LFWN-HVM White None G4LFWF HVM White FIRE Selectable Low 15, 30,75, G4LFRN-HVM Red None Frequency or 110 cd. G4LFRF-HVM Red FIRE (520 Hz)with 1.5 lbs. G4LFWN-H White None selectable (0.68 kg) G4LFWF-H White FIRE High/Low dB Audible G4LFRN-H Red None output. only. G4LFRF-H Red FIRE Accessories GSA-CC1S Intelligent Synchronization Output Module(2-gang) 0.5 (0.23) GSA-MCC1S Synchronization Output Module(Plug-inUlO) 0.18 (0.08) SIGA-CC2A Dual Input Signal Module with Class A Operation(2-gang) 0.5 (0.23) GSA-MCC2A Dual Input Signal Module with ClassAOperation(Plug-inUlO) 0.18 (0.08) EG4B Surface mount box,white 0.7 (0.32) EG4RB Surface mount box,red 0.7 (0.32) Page 4 of 4 DATA SHEET K85001-0639 Not to be used for installation purposes. Issue 1 Kidde Catalog Strobes,Horns,Bells,Chimes 4,r 0-- 0 Kidde United Technologies ---.-- Technology Technology that saves lives .............................::::::::::::...„ FleidGonfigurable Ilkiii . .. .... ............ Horns and Strobe0 ........ s_! z. Genesis Series F . .... ECS/MNSappliances available with clear or amber lenses. A — — All - " L �L E E � ALERT T 7 '� �L O MilAmi 1....1 <C> FC 7135-1483:APPROVED 0176 S218/ ME/4 (E 0147048 S2970/ Overview Standard Features The Genesis line of fire alarm and mass notification/emergency • Unique low-profile design communications(E CS/MNS)signals are among the smallest, — The most compact UL-1971/ULC-S526 listed strobe available most compact audible-visible life safety signaling devices in the — Ultra-slim—protrudes less than one inch world.About the size of a deck of playing cards,these devices are — Attractive appearance designed to blend with any decor. — No visible mounting screws Thanks to patented breakthrough technology, Kidde Genesis • Four field-configurable options in one device strobes do not require bulky specular reflectors and lenses. — Select 15, 30, 75, or 110 cd strobe output Instead,an exclusive cavity design conditions light to produce — Select high(default)or low dB horn output a highly controlled distribution pattern. Significant development — Select temporal(default)or steady horn output efforts employing this new technology have given rise to a new — Select public mode flash rate(default)or private mode benchmark in strobe performance—FullLight technology. temporal flash FullLight strobe technology produces a smooth light distribution • Fixed 15/75 cd model available pattern without the spikes and voids characteristic of specular re- • ECS/MNS models available flectors.This ensures the entire coverage area receives consistent illumination from the strobe flash.As a result,Genesis strobes with • Easy to install FullLight technology go well beyondthe UL-1971 and ULC-S526 — Fits standard 1-gang electrical boxes —no trim plate needed light distribution requirements. — Optional trim plate accommodates oversized openings — Pre-assembled with captive hardware Genesis strobes and horn-strobes offer selectable candela output — #12 AWG terminals—ideal for long runs or existing wiring by means of a conveniently-located switch on the side of the device.Models are also available that offer fixed 15/75 cd output. • Unparalleled performance The candela output setting remains clearly visible even after final — Industry's most even light distribution installation,yet it stays locked in place to prevent unauthorized — Meets tough synchronizing standards for strobes tampering. — Single microprocessor controls both horn and strobe — Independent horn control overa single pair of wires Genesis ECS/MNSappliances offer emergency signaling with — Highly regulated in-rush current clear or amber lenses and with optional ALERT housing labels. — Multiple frequencytone improves sound penetration They are ideal for applications that require differentiation between — Field-programmable temporal strobe output option fire alarm and mass notification alerts. Page 1 of 6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1 Application Installation Genesis strobes are UL 1971-listed for use indoors as wall-mount- Genesis horns and strobes mount to any standard one-gang sur- ed public-mode notification appliances forthe hearing impaired. face or flush electrical box.Matching optional trim plates are used Prevailing codes require strobes to be used where ambient noise to cover oversized openings and can accommodate one-gang, conditions exceed 105 dBA(87dBA in Canada),where occupants two-gang,four-inch square,or octagonal boxes,and European use hearing protection, and in areas of public accommodation 100 mm square. as defined in the Americans with Disabilities Act(see application All Genesis signals come pre assembled notes—USA). with captive mounting screws for easy in- Combination horn-strobe signals must be installed in accordance F stallation.Two tabs at the top of the signal with guidelines established for strobe devices.Consult with your , unlock the coverto reveal the mounting Authority Having Jurisdiction for details. R R hardware.The shallow depth of Genesis All Genesis strobes exceed UL synchronization requirementsE E devices leaves ample room behind the (within 10 milliseconds over a two-hour period)when used with a signal for extra wiring.Once installed with the cover in place,no mounting screws synchronization source. Synchronization is important in orderto avoid epileptic sensitivity. are visible. WARNING:These devices will not operate without electrical power.As fires frequently cause power interruptions,further safeguards such as Field Configuration Genesis Horn/Strobe Temporal horn and horn-strobe models backup power supplies may be required. with optionaltrim plate p are factory set to sound in a three-pulse temporal pattern Units may be con- figured for use with coded systems by cutting a jumper on the Horns circuit board.This results in a steady outputthat can be turned Genesis horn output reaches as high as 99 dB and features a on and off(coded)as the system applies and removes power to unique multiple frequency tone that results in excellent sound the signal circuit.A Genesis Signal Master is required when horn penetration and an unmistakable warning of danger. Horns may be strobe models are configured for coded systems.Non-temporal, configured foreither coded or no n-codedsignal circuits.They can horn only models sound a steady tone. also be set for low dB output with a jumper cut that reduces horn Genesis clear strobes and horn-strobes are shipped from the fac- output by about 5 dB.Horn-only models may be ceiling-mounted tory ready for use as UL 1971 compliant signals for public mode or wall-mounted. operation.These signals may be configured fortemporal flash by The suggested sound pressure level foreachsignaling zone used with cutting a jumper on the circuit board.This batterysaving feature is alarm signals is at least 15 dB above the average ambient sound level, intended for private mode signaling only. or 5 dB above the maximum sound level having a duration of at least Genesis clear strobes and horn-strobes may be set for 15,30,75, 60 seconds,whichever is greater,measured 5 feet(1.5 m)above the or 110 candela output.The output setting is changed by simply floor.The average ambient sound level is,A-weighted sound pressure opening the device and sliding the switch to the desired setting. measured overa 24-hourperiod. The device does not have to be removed to change the output Doubling the distance from the signal to the ear will theoretically result setting.The setting remains visible through a small window on the in a 6 dB reduction of the received sound pressure level.The actual side of the device after the cover is closed. effect depends on the acoustic properties of materials in the space. Horns and horn-strobes are factory set for high dB output. A 3 dBA difference represents a barely noticeable change in volume. Low dB output may be selected by cutting a jumper on the circuit board.This reduces the output by about 5 dB. ECS/MNS Applications Genesis ECS/MNSstrobe appliances bring the same high- performance fire alarm features and unobtrusive design to mass notification applications.Available with amber lenses and optional Wiring ALERT housing labels,they are ideal for applications that require Field wiring terminals accommodate#18 to#12 AWG(0.75 mm2 differentiation between fire alarm and mass notification alerts. to 2.5 mm2)wiring.Horns,strobes,and combination horn-strobes are interconnected with a single pair of wires as shown below. 0 To next appliance, Polarity shown in end-of-line alarm condition ____________________________ or return to control 11+? C19 equipment ONote:Strobes must have continuous voltage. Page2of6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1 Current Draw Strobes,Horn-Strobes Horns Multi-cd Wall Strobes(EG1-VM) Wall or Ceiling Mounted UL 15 cd* 30 cd* 15/75cd** 75 cd* 110 cd* Temporal Horns(EG1-HD) Rating RMS RMS RMS RMS RMS UL High dB Low dB 16 Vdc 103 141 152 255 311 Rating (RMS) (RMS) 16 Vfwr 125 179 224 346 392 16 Vdc 26 19 *EG1-VMmulti-cd;**EG1F-V1575fixed 15/75 cd 24 Vdc 36 27 33 Vdc 41 33 Typical 15 cd 30 cd 15/75 75 cd 110 cd 16 Vfwr 51 37 Current RMS RMS RMS RMS RMS 24 Vfwr 69 52 16 Vdc 85 127 150 245 285 33 Vfwr 76 70 20 Vdc 71 98 123 188 240 24 Vdc 59 82 104 152 191 Typical High dB Low dB 33 Vdc 46 64 84 112 137 Current RMS RMS 16 Vfwr 119 169 223 332 376 16 Vdc 22 17 20 Vfwr 103 143 189 253 331 20 Vdc 24 19 24 Vfwr 94 129 169 218 262 24 Vdc 27 22 33 Vfwr 87 112 148 179 205 33 Vdc 32 26 16 Vfwr 34 30 Wall Temporal Horn-strobes—High dB Setting 20 Vfwr 40 34 15 30 15/75 75 110 *EG1-HDVM multi-cd 24 Vfwr 45 38 UL Rating cd* cd* cd** cd* cd* **EG1F-HDV1575fixed 15/75 cd 33Vfwr 52 47 RMS RMS RMS RMS RMS 16 Vdc 129 167 172 281 337 Wall or Ceiling Mounted Horns(EG1-P) 16 Vfwr 176 230 269 397 443 UL Designation Voltage Range Max.Current, RMS Typical 15 cd 30 cd 15/75 75 cd 110 cd Regulated 24 16 33 Vdc 13 mA Current RMS RMS RMS RMS RMS Vdc 16 Vdc 102 135 160 246 309 24 fwr 16 -33 Vfwr 11 mA 20 Vdc 88 109 137 193 248 24 Vdc 81 94 122 161 203 Typical Current RMS 33 Vdc 74 72 106 124 154 24 Vdc 10 16 Vfwr 144 182 247 352 393 24 Vdc 11 20 Vfwr 141 162 220 274 362 31 Vdc 12 24 Vfwr 136 152 203 235 282 20 Vfwr 9 33 Vfwr 125 144 196 201 232 24 Vfwr 10 Wall Temporal Horn-strobes—Low dB Setting Current values are shown in mA. 15 30 15/75 75 110 UL cd* cd* cd** cd* cd* Rating RMS RMS RMS RMS RMS 16 Vdc 122 160 146 274 330 *EG1-HDVMmulti-cd 16 Vfwr 162 216 231 383 429 **E G1F-HDV1575 fixed 15/75 cd Typical 15 cd 30 cd 15/75 75 cd 110 cd Current RMS RMS RMS RMS RMS 16 Vdc 96 130 158 243 302 20 Vdc 79 104 133 189 241 24 Vdc 68 88 119 156 197 33 Vdc 56 71 100 118 146 16 Vfwr 128 180 241 344 389 20 Vfwr 118 157 _ 213 266 343 24 Vfwr 113 144 195 230 279 33 Vfwr 112 137 182 197 226 Page3of6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1 dBA output Average Sound Output (dBA) Temporal Horns,Horn-strobes (High dB setting,anechoic,24V,measured at 10ft) (EG1-HD, EG1-HDVM series) HighUL464 Average Peak 90°r,zo„o,00 so ao ,o so so ao 3o zo , zo 3o ao so so ,o ao so ,00„o,zo 9°° dB Temporal Steady Temporal/ Temporal/ Setting Steady Steady ,5 /75° 16 Vdc 81.4 85.5 91.4 94.2 / 24 Vdc 84.4 88.6 94.5 97.6 -60\ 60° 33 Vdc 86.3 90.4 96.9 99.5 / 45°\ /45 Low dB UL464 Average Peak Temporal/ Temporal/ -30° �30° Setting Temporal Steady Steady Steady -15° o° 15° 16 Vdc 76.0 80.1 86.3 89.2 24 Vdc 79.4 83.5 89.8 92.5 Light output - (effective cd) 33 Vdc 82.1 86.5 92.5 95.3 Percent of UL rating versus angle Steady Tone Horns(EG1-P series) UL464 Average Peako o,00 90 ao ,o eo a ,a0 20 40 eo ,o 80 ao,00„a,zo 16 Vdc 77 dBA,min 85 dBA 91 dBA 2 16 Vfwr 77 dBA,min 85 dBA 91 dBA -]5°\ /75° Notes 1. All values shown are dBA measured at 10 feet(3.01m). . /60° 2. UL464 values measured in reverberant room. \ 3. Average and Peak values are measured in anecho is chamber. ,50N /45° -30,___ �30° \15°�--- 15: 0° Specifications Housing Red or white textured UV stabilized,color impregnated engineered plastic.Exceeds94V-0 UL flammability rating. Lens Optical grade polycarbonate(clear) Strobes and horn-strobes are for wall-mo unt installation only.Horn-only models may be ceiling-or wall-mounted. Mounting Flush mount:2152 inch(64 mm)deep one-gang box (indoor only) Surface mount:Model 27193 surface mount box,wiremold box,or equivalent surface-mount box With optional trim plate:One-gang,two-gang,four-inch square,octagonal,or European single-gang box Wire connections Screw terminals:single input for both horn and strobe.#18 to#12 AWG(0.75 mm2 to 2.5 mm2)wire size Operating environment Indoor only:32-120°F (0-49°C)ambient temperature.93%relative humidity Agency listings/approvals UL 1971 (S218), UL 1638 (S218), UL 464(S218), ULC S525,ULC S526,CSFM,CE,FCC,MEA. (All models comply with ADA Code of Federal Regulation Chapter28 Part 36 Final Rule.) Dimensions(HxWxD) Signal:4-1/2"x 2-3/4"x 13/16" (113 mm x 68 mm x 21 mm) Trimplate: 5"(127 mm);Height—5-7/8"(149 mm);Depth-1/2"(13 mm) E G1-HD series temporal-tone horns:non-coded,filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR(or coded when horn set to steady tone) Operating voltage E G1-HDVM series temporal-tone horn-strobes:non-coded,filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only)when used with optional EG1M Genesis Signal Master) E G1-VM series strobes:non-coded,filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR E G1-P series steady-tone horns:coded or non-coded,filtered 20-31 Vdc or unfiltered 20-27 Vfwr UL 1971, UL 1638, ULC S526:selectable 15 cd,30 cd,75 cd,or 110 cd output Strobe output rating UL 1971: 15 cd(fixed 15/75 cd models) UL 1638, ULCS526:75 cd(fixed 15/75 cd models) E G1-VM strobes and E G1-HDVM series temporal-tone horn-strobes:one flash per second synchronized with optional Strobe flash rate E G1M Genesis Signal Master indefinitely within 10 milliseconds.Temporal setting(private mode only):synchronized to temporal output of horns on same circuit Synchronization Sources FACPs:VM and VS Series life safety systems,FX Series fire alarm control panels.Moduels:GSA-CC1S,GSA-MCC1S, SIGA-CC2A,GSA-MCC2A,E G1M-RM.Power supplies:MIRBPS6A, MIRBPS10A,APS6A,APS10A. E G1-HD temporal-tone horns and E G1-HDVM series temporal-tone horn-strobes:temporal rate synchronized with Horn pulse rate optional E G1M Genesis Signal Master indefinitely within 10 milliseconds.E G1-P steady-tone horns:continuous,steady tone only Temporal audible pattern 1/2 sec ON,1/2 sec OFF,1/2 sec ON,1/2 sec OFF,1/2 sec ON,11/2 sec OFF,then repeat cycle Page 4 of 6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1 Candela Output Fire appliances available with white or red housings. Switch Switch Switch F Ft Lens Switch ee .__•1 6 __ ImiL R R Rating Position Position Position FIRE e e Color Position A B C D •+r±- Amber UL 1638 110 cd 75 cd 30 cd 15 cd Amber UL 1971" 88 cd 60 cd 24 cd 12 cd Clear UL 1971 110 cd 75 cd 30 cd 15 cd ECS/MNSappliances available with clear or amber lenses. *Equivalent Rating A LIALErnI L _ mall ALERT T � 'rill Ordering Information Model I Housing I Marking I Lens I Strobe I Horn I Ship Wt.lbs(kg) Fire Alarm Appliances(c/w running man icon screen printed on housing) EG1-VM White None Clear Selectable 15, 30,75,or 110 cd Strobe only 0.25 (0.11) EG1F-HD White FIRE Clear Horn only Selectable high/lowdB 0.25 (0.11) EG1F-HDV1575 White FIRE Clear 15/75 cd1 Temporal hi/lo dB-24V 0.25 (0.11) EG1F-HDVM White FIRE Clear Selectable 15, 30,75,or 110 cd Selectable high/lowdB 0.25 (0.11) EG1F-P White FIRE Clear Steady Horn(not compatible with Genesis Signal Master) _ 0.25 (0.11) EG1F-V1575 White FIRE Clear 15/75 cd1 Strobe only 0.25 (0.11) EG1F-VM White FIRE Clear Selectable 15, 30,75,or 110 cd Strobe only 0.25 (0.11) EG1-HD White None Clear Horn only Selectable high/lowdB 0.25 (0.11) EG1-HDVM White None Clear Selectable 15, 30,75,or 110 cd Selectable high/lowdB 0.25 (0.11) E G1-P White None Clear Steady Horn(not compatible with Genesis Signal Master) 025 (0.11) EG1RF-HD Red FIRE Clear Horn only Selectable high/lowdB 0.25 (0.11) EG1RF-HDV1575 Red FIRE Clear 15/75 cd1 Temporal hi/lo dB-24V 0.25 (0.11) EG1RF-HDVM Red FIRE Clear Selectable 15, 30,75,or 110 cd Selectable high/lowdB 0.25 (0.11) EG1RF-P Red FIRE Clear Steady Horn(not compatible with Genesis Signal Master) 0.25 (0.11) EG1RF-V1575 Red FIRE Clear 15/75 cd1 Strobe only 0.25 (0.11) EG1RF-VM Red FIRE Clear Selectable 15, 30,75,or 110 cd Strobe only 0.25 (0.11) EG1R-HD Red None Clear Horn only Selectable high/lowdB 0.25 (0.11) EG1R-HDVM Red None Clear Selectable 15, 30,75,or 110 cd Selectable high/IowdB 0.25 (0.11) EG1R-P Red None Clear Steady Horn(not compatible with Genesis Signal Master) 0.25 (0.11) EG1R-VM Red None Clear Selectable 15, 30,75,or 110 cd Strobe only 0.25 (0.11) ECS/MNS Appliances(no running man icon on housing) G1WA-VMA White ALERT Amber Selectable A,B,C or D Strobe only 0.25 (0.11) G1WA-VMC White ALERT Clear Selectable 15, 30,75,or 110 cd Strobe only 0.25 (0.11) G1WN-VMA White None Amber Selectable A,B,C or D Strobe only 0.25 (0.11) G1WN-VMC White None Clear Selectable 15, 30,75,or 110 cd Strobe only 0.25 (0.11) Trim Plates EG1T White None Genesis Trim Plate(for two-gangor4"square boxes) 0.15 (0.7) E GIRT Red None Genesis Trim Plate(for two-gang or 4"square boxes) 0.15 (0.7) EG1T-FIRE White FIRE Genesis Trim Plate(for two-gangor4"square boxes) 0.15 (0.7) EG1RT-FIRE Red FIRE Genesis Trim Plate(for two-gang or4"square boxes) 0.15 (0.7) G1 WT-ALERT White ALERT Genesis Trim Plate(for two-gang or 4"square boxes) 0.15 (0.7) Surface Boxes 27193-16 White N/A One-gang surface mount box 1 (0.4) 27193-11 Red N/A One-gang surface mount box 1 (0.4) I These 15/75 cd models provide fixed output and are not multi-candela devices.The 15 cd output component complies with UL1971, while the 75 cd output component complies with UL 1638. Page5of6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1 Kidde Technology that saves lives Contact us... Email:kidde.fire@fs.utc.com Web: Kidde.com/EngineeredSystems Kidde is a UTC brand. 1016 Corporate Park Drive Mebane,NC 27302 ©2016 United Technologies Corporation. All rights reserved. Page 6 of 6 DATA SHEET K85001-0573 Not to be used for installation purposes. Issue 1 Kidde Catalog►Strobes,Horns,Bells,Chimes 4,r 0-- 0 �K•d de United Technologies IIr Technology that saves lives , . . _'..'''''' ,;' liill: Outdoor Rated :. ... ..... . . "........ ,, .................. ,, :........... .: •-•.•... - • ........... ..... . , •.,......... , ............... Hornsand • ,, ........... .. .... . R ..: Horn Strobes • Genesis WG4 Series z_ -- .y6 ‘,. 1,,,.,Y.' 4 , . Overview Standard Features Genesis WG4 Series horns and horn-strobe appliances are among • Outdoor and indoor rated the most versatile emergency appliances of their kind. Rated for • Low profile design indoor or outdoor use,they are suitable fora wide range of wet and harsh environments with a listed operating temperature range • Wall or ceiling mount of as low as-40°F to as high as 151 °F(-40°C to 66°C). • Room-side wiring accepts 18 to 12 AWG(0.75 to 2.5 mm2) Field-configurable light and sound output settings add to their on- • Wide operating temperature range site flexibility,while optional FIRE markings make them ideal for fire alarm applications. • Field-selectable settings These appliances are suitable for indoor and outdoor applications, • Fully compatible with Genesis synchronization protocols and are ideal for challenging conditions such as parking garages • Standard and high-output strobe intensities and process areas.They are available for mounting on the ceiling • or the wall,and thanks to an ingenio us optional full backplane Horn only and horn strobe options sealing gasket,can be installed to recessed(in-the-pour/block) electrical boxes.WG4 notification appliances also mount to suit- able surface boxes.Optional color-matched trim skirts provide a clean,finished appearance.All appliance wiring is accomplished room-side for easy installation. WG4 Series appliances feature an efficient and powerful p iezo sounder.The multi-candela strobes are available with clear lenses in two output categories—standard and high-output.They are precision-timed to meet UL 1971 synchronization standards, and field-configurable for one of four candela intensities.Candela settings are viewable even after installation thro ugh an innovative sealed viewport display. Page 1 of 4 DATA SHE El K85001-0628 Not to be used for installation purposes. Issue 1 Application Installation and Mounting Horns WG4 Gasket Optional trim skirt \ Genesis horn output reaches as high as 97 dBA in accordance with UL 464(104 dBA in accordance with ULC-S525)and features a Backplate m ` O� unique frequency tone that results in excellent sound penetration and an unmistakable warning of danger. Horns may be configured Front cover \ � � foreither coded or non-coded notification circuits.They can also be set for low dB output with a jumpercut that reduces horn output by \ 1•1, / ; 0 about 5 dB. Ok A The suggested sound pressure level foreach notification zone used � ±� ' � �% , , with alarm notification appliances is at least 15 dB above the average )`;i t,l?i f.,\5 ► Electrical ,,.,, I�r- box ambient sound level,or 5 dB above the maximum sound level having a aP sl.,E{;;,< 1; M 1., duration of at least60 seconds,whichever is greater,measured 5 feet i ^` (1.5 m)above the floor.The average ambient sound level is A-weighted ', �♦j (fast response)sound pressure measured overa 24-hourperiod. ��� � x+114 �i Doubling the distance from the notification appliance to the ear will 1 ) `v theoretically result in a 6 dB reduction of the received sound pressure level.The actual effect depends on the acoustic properties of materi- als in the space. A 3 dBA difference represents a barely noticeable to change in volume. WG4 notification appliances are rated foroutdooruse and are suitable forindoor or outdoorapplications on walls or ceilings.For surface-mounting in outdoor or wet applications,appliances must be Strobe Application mounted to a 449 or74347Uelectrical box. In dry conditions,they Genesis clear-lensed strobes are UL 1971-listed for use indoors are compatible with standard 4-inch square by 11/2-inch deep electri- as wall-or ceiling-mounted public-mode notification appliances for cal boxes.When using the optional WG4WTS orWG4RTS trim skirt, the hearing impaired, and UL 1638-listedforoutdoorapplications. a 449 or4-inch square by2-1/8"deep box must be used. Prevailing codes require strobes to be used whereambient noise conditions exceed specified levels,where occupants use hearing The Genesis WG4 horn and horn-strobe may be wall-or ceiling- protection, and in areas of public accommodation. mounted,and may be placed in one of four positions:strobe above, strobe below,and strobe to either side.The shallow depth of Gen- Visible appliance synchronization is required to avoid causing esis devices leaves room behindthe appliance forextra wiring. issues with people who have Photosensitive Epilepsy(PSE). Noti- fication appliance synchronization is also generally required when morethan two strobe appliances are in the same field of view from Field Configuration Wire slot any one location.All Genesis strobes meet UL synchronization Horn pattern:Audible , requirements(within 10 milliseconds over a two-hour period)when output forWG4 horns and O 0_irro \ used with a synchronization source. horn-strobes is factory set to to sound in a three-pulse ®O®� temporal pattern.Units may WAR NING:These devices will not operate without electrical power. be configured for use with As firesfrequentlycause powerinterruptions,we suggest yo u discuss \ Horn further safeuardswith your local fires specialist. coded systems by cutting IS� �F+J volume 9 protectionp a JP1 on the circuit board. candela n — setting I Q \ jumper Kidderecommendsthatthesedevicesalwaysbeinstalledinaccordance This results in a steady switch I`+Iz}'is+'i`+Yi with the latest recognized edition of natio nal and local codes.Referto output that can be turned (S2) r] the appropriatecodesand standardsformounting height information. on and off(coded)as the ¢ � , system applies and removes Horn 0- 3A0Woi power to the notification pattern_°" k / jai circuit.A Genesis Signal jumper ��I`®m� -m Master is required when Strobe ?� �+ horn-strobe models are con- pattern figured for coded systems. jumper(JP4) Horn output:Horns and horn-strobes are factory set for high dB output. Low dB output may be selected by cutting a jumper on the circuit board. This reduces the output by about 5 dB. Strobe pattern:Genesis WG4 horn-strobes are factory set for use as UL 1971 compliant notification appliances for public mode operation.These notification appliances may be configured fortemporal flash by cutting JP4 on the circuit board.This battery-saving feature is intended for private mode signaling only. Strobe output:Genesis WG4 horn-strobes may be set for one of four out- put intensities.The output setting is changed by simply opening the device and sliding the switch to the desired setting.The device does not have to be removed to change the output setting.The setting remains visible after the cover is closed thro ugh a small window on the front of the device. Page 2 of 4 DATA SHEET K85001-0628 Not to be used for installation purposes. Issue 1 Wiring Light Output Angle Field wiring is connected to WG4 notification appliances with Horizontal Plot 20-15 -5 ° 5 1° 15 20 terminals that accommodate#18 to#12 AWG(0.75 mm2 to 2.5 ,°-25 25 30 mm2)wiring. 40-35 35 40 -45 45 Signal In- Signal Out - -50 50 -55 55 .60 60 Signal In + -�� , , �I Signal Out + -65 65 -70 70 1TT'1 int � ® -75 75 so 8° O Qp -85 85 90 90 - :I 10 I(CMI, m g 12 2 S n 2 Percentage of g r g rAutp output 2 2 g 2 2 2 g oQ Standard Candela Horn-strobes e ®:m0 Standard/rating Strobe Switch Position D C B A -/+designations indic atethe signal polarity UL 1971 Indoor 15 cd 29cd 70 cd 87 cd required to ac tivatethe device. UL 1638 Outdoor @-35°C 6 cd 12 cd 28 cd 35 cd CAN/ULC-S526 Outdoor @-40°C 1 cd 3 cd 8 cd 10 cd High Candela Horn-strobes Specifications Strobe Switch Position Horns and Horn-strobes Standard/rating D C B A UL 1971 Indoor 102 cd 123cd 147cd 161cd Operating voltage 24VDC,24VFWR nominal UL 1638 Outdoor @-35°C 41cd 50 cd 60 cd 65 cd Dimensions(W x H x D) 5.6 x 8.5 x 1.4 in.(142 x 216 x 36 mm) CAN/ULC-S526 Outdoor @-40°C 11 cd 14 cd 17 cd 18 cd Horn tone 3.2 kHz Wire size 12 to 18 AWG(0.75 to 2.50 mm2) Compatible electrical box Outdoor Model 449 or 74347U Indoor 4 in.square by 1.5 in.deep box Operating Current Operating environment (ULspecifies current ratings at 16 volts) Temperature -40 to 151°F (-40 to 66°C) Standard Candela Horn-strobes in R MS(mA),continuous Relative humidity 0 to 95%no nco ndensing Input Voltage Strobe Switch Position D C B A 16 VDC 127 168 297 351 Compatible Synchronization Sources 16 VFWR 218 239 393 422 Horn-strobes 24VDC 107 130 210 238 24VFWR 190 222 325 356 Auto sync Output Modules GSA-CC1S,SIGA-CC2A,GSA- MCC1S, GSA-MCC2A High Candela Horn-strobes in R MS(mA),continuous Genesis Signal Master EG1M-RM Strobe Switch Position Booster&AuxiliaryPowerSupplies APS6A,APS10A,MIRMIRBPS6A, Input Voltage D C B A MIRMIRBPS10A Control Panels with Genesis 16 VDC 342 408 517 526 Synchronization built-in VS Series,VM Series,FX Series 16 VFWR 447 502 614 679 24VDC 240 271 327 365 24VFWR 390 400 486 540 Sound Output Horn only models(mA) Horns and Horn-strobes(dBA) 16V RMS,continuous 24V,typical 16V 24V 33V Setting High dB Low dB High dB Low dB Volume Setting UL ULC- UL ULC- UL ULC- VDC 69.1 41.2 49.0 32.3 464 S525 464 S525 464 S525 VFWR 135 91.3 99.1 67.1 Continuous High 89.7 94.0 94.7 99.6 97.4 102.9 Continuous Low 85.4 92.8 89.5 97.2 92.5 98.6 Temporal High 84.2 96.5 90.5 100.5 93.5 104.2 Temporal Low 81.7 90.3 85.4 94.2 88.1 97.0 dBA=Decibels,A-weighted. UL 464:Sound level output measured in a reverberant room at 10 ft.(3.05m). CAN/ULC-5525:Sound level output measured in an anechoic room at 10ft(3.05m). Page 3 of 4 DATA SHEET K85001-0628 Not to be used for installation purposes. Issue 1 Ordering Information II 1' Kidde F s R Technology that saves lives WG4RF-H WG4RF-HVMC WG4WF-H WG4WF-HVMC WG4RN-H WG4RN-HVMC WG4WN-H WG4WN-HVMC Contact us... Email:kidde.fire@fs.utc.com Model Housing Marking Strobe Output Ship Wt. Web: Kidde.com/EngineeredSystems WG4RF-HVMC Red Kidde is a UTC brand. WG4WF-HVMC White FIRE Selectable 1016 Corporate Park Drive WG4RN-HVMC Red standard candela Mebane,NC 27302 None Output WG4WN-HVMC White ©2016 United Technologies Corporation. WG4RF-HVMHC Red All rights reserved. FIRE Selectable WG4WF-HVMHC White 1.5 lbs. high candela WG4RN-HVMHC Red output (0.68kg) None WG4WN-HVMHC White WG4RF-H Red FIRE WG4WF-H White WG4RN-H Red Horn Only None WG4WN-H White Accessories WG4WTS Surface Skirt for Genesis WG4 appliance family,white. WG4RTS Surface Skirt for Genesis WG4 appliance family,red. WG4GSKT Full Body Mounting Gasket for smooth surfaces,WG4 appliance family 74347U _ Surface mount box,outdoor rated,red 449 Surface mount box,outdoor rated,gray Page 4 of 4 DATA SHEET K85001-0628 Not to be used for installation purposes. Issue 1 POWER ///% + + 4-.50A//1 PS-12120E 12 Volt 12.0 AH + Rechargeable Sealed Lead Acid Battery We've Got The Power.'a" Features • Absorbent Glass Mat (AGM)technology for superior performance • Valve regulated,spill proof construction allows safe seal d Rerliar ea°fie ^,I'�r` savary operation in any position MODEL PS12120L • Power/volume ratio yielding unrivaled energy density 11 Wry 11220OW W • Rugged impact resistant ABS case and cover (UL94-HB) pb -- _ _ • Approved for transport byair. D.O.T., I.A.T.A., F.A.A.and C.A.B. certified CE • U.L. recognized under file number MH 20845 Mary,, 1111rl, °l Terminals (mm) Performance Specifications Nominal Voltage 12 volts(6 cells) • FP:Positive:0.250" Fl F2 Nominal Capacity x 0.032", Negative: -3.2-♦ I3.4-1 20-h r. (600mA to 10.50 volts) 12.0 AH 0.187"x 0.032". 1111.111475 B1=6.35 Mate with AMP.INC 10-hr. (1.19A to 10.50 volts) 11.9 AH FASTON "250/187" H6.35H=u6 H7.95H=06 5-hr. (2.21A to 10.20 volts) 11.1AH series 1-hr. (8A to 9.00 volts) 8.00 AH 15-min.(25.5A to 9.00 volts) 6.38 AH Physical Dimensions:in (mm) Approximate Weight 8.80 lb s.(3.99 kg) Energy Density(20-hr.rate) 1.08 W-h/in3(65.77 W-h/l) T Specific Energy(20-hr.rate) 16.36 W-h/lb(36.08 W-h/kg) W Internal Resistance(approx.) 25 milliohms 00 Max Discharge Current(7 Min.) 36.0 amperes Max Short-Duration Discharge Current(10 Sec.) 50.0 amperes Shelf Life(%of nominal capacity at 68°F(20°C)) 1 Month 97% HT H 3 Months 91% MODEL PS 12120L 1 'rs.�rma. 6 Months 83% I OperatingTemperature Range H L H Charge -4°F(-20°C)to122°F(50°C) Discharge -40°F(-40°C)to 140°F(60°C) L:8.45(215) W:2.75(70) H:5.75(146) HT:5.75(146) Case ABS Plastic Tolerances are+/-0.04 in.(+/-1mm)and+/-0.08 in.(+/-2mm)for Power-Sonic Chargers PSC-122000A, 122000A-C height dimensions.All data subjectto change without notice. To ensure safe and efficient operation always referto the latest edition of our Technical Manual,as published on our website. All data subject to change without notice. www.power-sonic.com POWER, """"""""""""""""""" PS-12120E 12 Volt 12.0 AH �����������7//SON/C Shelf Life&Storage Discharge Characteristics 100 14.0 1 1 1 1 1 III 1 1 c Chargingisnot Ambient Temperature20°C 68°F necessary unless ( ) O 100%of capacity 13.0 is required. - 80 > ---__ 5°C Chargingbefore _ use is necessary a 12.0 -- o (41°F) to help recover Ot full capacity. co -- '-------7------------------------------- a 60 D 11.0 .) .� Chargemayfail - to restorefull 0.6Q w 40°C 30°C 2 1C Icapacity.Do not E 10.0 I\ 1.2 - - .v 40 (104°F) (86°F) (68°F) let batteries reach E I 2.4 a r this state. y 6.0 f6 0 I- 9.0 Final U 0 2 4 6 8 10 12 14 16 18 2012 Voltage Standing Period(Months) 8.0 24 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0 Discharge Time vs.Discharge Current 1...._ min ►1 h D ischargeTime 20 15 \\\ \ Life Characteristics in Stand-ByUse _. \ AmbientTemperature 20°C(68°F) 0 5 Final , e 100 1 E Voltage w 2 10.5V \\ •5 80 t10.2V 0. 60 o 1 \ v Float ChargingVoltage a o 40 - 2.25-2.30 V/Cell 30 9.6V \\ a 20 m c \ re 0 9.0V 0 1 2 3 4 10 \ \40°C(104°F) 20°C (68°F) Years 0°C (32°F) 5 8.1V 1 Life Characteristics in Cyclic Use 0.60 1.2 2.4 6.0 12 24 120 D ischargeCurrent(A) 100 .fr,___,\,,_...\..,..,......, Charging o ,, 80 • Cycle Applications:Limit initial currentto 3.6A.Charge until batteryvoltage ra (under ch arge)reach es 14.4 to 14.7 volts at 68°F(20°C).Hold at 14.4 to 14.7 R 60 Discharge Discharge Discharge volts until currentdrops to under 120mA.Battery is fully charged under these Depth 100% Depth 50% Depth 30% conditions,and ch argersh ould be disconnected or switch edto"float"voltage. 0 40 - y 1.Discharge Current0.2C(Final Voltage 1.7V/Cell) "Float"or"Stand-By"Service:Hold b atteryacross constant voltage source of m 20 2.Charge Current:0.1C I I I 13.5 to 13.8 volts continuously.When held at th isvoltage,the battery will seek its re 3.Ambient Temperature:20°C to 25°C(68°F to 77°F) own current level and maintain itself in a fully charged condition. 0 1 0 200 400 600 800 1000 1200 Note:Due to the self-discharge characteristics of this type of battery,it is Number of Cycles imperativethat they b echarged within 6 months of storage,otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Further Information Power-Sonic offers a wide range of chargers suitab lefor batteries up to 100AH. Please refer to our website www.power-sonic.com fora complete range of useful Please refer to the Ch argerSelection Guide in our specification sh eetsfor"C-Series downloads,such as product catalogs,material safetydata sheets(MS DS),ISO Switch Mode Chargers"and"Transformer Type A and F Series".Please contact our certification,etc.. Tech nicaldepartment for advice if you h avedifficulty in locating suitable models. Contact Information www.power-sonic.com DOMESTIC SALES CUSTOMER SERVICE TECHNICALSUPPORT INTERNATIONAL SALES Tel:+1-619-661-2020 Tel:+1-619-661-2030 Tel:+1-619-661-2020 Tel:+1-650-364-5001 Fax:+1-619-661-3650 Fax:+1-619-661-3648 Fax:+1-619-661-3648 Fax:+1-650-366-3662 national-sales@power-sonic.com customer-service@power-sonic.com support@power-sonic.com battery@power-sonic.com CORPORATE OFFICE• 7550 Panasonic Way•San Diego,CA 92154• USA• Tel:+1-619-661-2020 • Fax:+1-619-661-3650 0309 1M + +4-+ 4-. , , / , 50A//1" PS-1270 12 Volt 7.0 AHILIIt+ . .4 Rechargeable Sealed Lead Acid Battery We've Got The Power.'a" Features • Absorbent Glass Mat (AGM)technology for superior performance • Valve regulated,spill proof construction allows safe Sealed Rechargeable Battery operation in any position // /////////////// pau/Eigill/%/i ONO � �/ ��/"""far • Power/volume ratio yielding unrivaled energy density MODEL PS-1270 F1 12 Volt 7 DAMP_Hr_ °,o* ��,._ °m • Rugged impact resistant ABS case and cover (UL94-HB) • Approved for transport byair. D.O.T., I.A.T.A., F.A.A.and C.A.B. certified CE • U.L. recognized under file number MH 20845 - i�rl, em Terminals (mm) Performance Specifications • Fl-Quick disconnect Nominal Voltage 12 volts(6 cells) tab s,0.187"x 0.032"- Mate with AMP.INC. F1 F2 Nominal Capacity FASTON "187"series I-32j 1-3.4-1 20-hr. (350mA to 10.50 volts) 7.00AH -OR- Mai I4.75 II_6.35 10-hr. (650mA to 10.50 volts) 6.50AH • F2-Quick disconnect tabs,0.250"x 0.032" I-6.35-1=us I-7.95-1X08 5-hr. (1.2A to 10.20 volts) 6.00AH -Mate with AMP.INC 1-hr. (4.5A to 9.00 volts) 4.50 AH FASTON "250"series 15-min.(14Ato 9.00 volts) 3.50 AH Physical Dimensions:in (mm) Approximate Weight 4.80 lb s.(2.18 kg) Energy Density(20-hr.rate) 1.49 W-h/in3(90.95 W-h/l) ISpecific Energy(20-hr.rate) 17.50 W-h/lb(38.58 W-h/kg) W Internal Resistance(approx.) 23 milliohms D DJ 1 Max Discharge Current(7 Min.) 21.0 amperes Max Short-Duration Discharge Current(10 Sec.) 70.0 amperes f- . Shelf Life(%of nominal capacity at 68°F(20°C)) i111��� s, 1 1 Month 97% �Y" ar I POLI/EB+ SrO oi. HT H 3 Months 91% MODEL POS-UF F, (4 I 6 Months 83% OperatingTemperature Range L H Charge -4°F(-20°C)to122°F(50°C) Discharge -40°F(-40°C)to 140°F(60°C) L:5.95(151) W:2.56(65) H:3.70(94) HT:3.86(98) Case ABS Plastic Tolerances are+/-0.04 in.(+/-1mm)and+/-0.08 in.(+/-2mm)for Power-Sonic Chargers PSC-12800A, 12800A-C height dimensions.All data subjectto change without notice. To ensure safe and efficient operation always referto the latest edition of our Technical Manual,as published on our website. All data subject to change without notice. www.power-sonic.com POWER��� ���%iSrNN/C/ ���� PS-1270 12 Volt 7.0 AH Shelf Life&Storage Discharge Characteristics 100 14.0 III 1 1 III 1 1 c Chargingisnot Ambient Temperature20°C 68°F necessary unless ( ) O 100%of capacity 13.0 is required. - tY 80 > ----- 5°C Chargingbefore _ use is necessary a 12.0 -- o (41°F) to help recover Ot full capacity. ;a -- Th-----------------Th a 60 D 11.0 Z.) .� Charge mayfailI\ to restore full m w 40°C 30°C 2 1C capacity.Do not E 10.0 1.70 -0.35 - .v 40 (104°F) (86°F) (68°F) let batteries reach E I 1.4 a :=- this state. y 3.5 f6 0 1- 9.0 Voltage Final U 0 2 4 6 8 10 12 14 16 18 20 7.0 Standing Period(Months) 8.0 14 1.2 2.4 6 12 24 36 48 1 2 4 6 8 10 20 4 0 DischargeTime vs.DischargeCurrent hi__ min 1.- 1 h D ischargeTime 20 15 10 \ Life Characteristics in Stand-By Use _. \ AmbientTemperature 20°C(68°F) d 5 Final , e 100 1 E Voltage w 2 10.5V \\ •5 80 ea t 10.2V m 60 1 \ v Float ChargingVoltage a o 40 - 2.25-2.30 V/Cell 30 9.6V \\ ca 20 m c \ re 0 9.0V 0 1 2 3 4 10 \ \40°C(104°F) 20°C (68°F) Years 0°C (32°F) 5 8.1V 1 Life Characteristics in Cyclic Use 0.35 0.70 1.4 3.5 7.0 14 120 D ischargeCurrent(A) 100 -1"-\\ Charging o ,, so Cycle Applications:Limit initial currentto 2.1A.Charge until b atteryvoltage rraa (under charge)reaches 14.4 to 14.7 volts at 68°F(20°C).Hold at 14.4 to 14.7 R 60 Discharge Discharge Discharge volts until currentdrops to under 70mA.Battery is fully charged under these 0 Depth 100% Depth 50% Depth 30% conditions,and ch argersh ould be disconnected or switch edto"float"voltage. 0 40 - y 1.Discharge Current0.2C(Final Voltage 1.7V/Cell) "Float"or"Stand-By"Service:Hold b atteryacross constant voltage source of m 20 2.Charge Current:0.1C I I 1 13.5 to 13.8 volts continuously.When held at th isvoltage,the battery will seek its re 3.Ambient Temperature:20°C to 25°C(68°F to 77°F) own current level and maintain itself in a fully charged condition. 0 0 200 400 600 800 1000 1200 Note:Due to the self-discharge characteristics of this type of battery,it is Number of Cycles imperativethat they b echarged within 6 months of storage,otherwise permanent loss of capacity might occur as a result of sulfation. Chargers Further Information Power-Sonic offers a wide range of chargers suitab lefor batteries up to 100AH. Please refer to our website www.power-sonic.com fora complete range of useful Please refer to the Ch argerSelection Guide in our specification sh eetsfor"C-Series downloads,such as product catalogs,material safetydata sheets(MS DS),ISO Switch Mode Chargers"and"Transformer Type A and F Series".Please contact our certification,etc.. Tech nicaldepartment for advice if you h avedifficulty in locating suitable models. Contact Information www.power-sonic.com DOMESTIC SALES CUSTOMER SERVICE TECHNICALSUPPORT INTERNATIONAL SALES Tel:+1-619-661-2020 Tel:+1-619-661-2030 Tel:+1-619-661-2020 Tel:+1-650-364-5001 Fax:+1-619-661-3650 Fax:+1-619-661-3648 Fax:+1-619-661-3648 Fax:+1-650-366-3662 national-sales@power-sonic.com customer-service@power-sonic.com support@power-sonic.com battery@power-sonic.com CORPORATE OFFICE• 7550 Panasonic Way•San Diego,CA 92154• USA• Tel:+1-619-661-2020 • Fax:+1-619-661-3650 0308 1M