HomeMy WebLinkAboutB18-0278_Approved Documents_1534860105.pdf75 South Frontage Road
West,
Vail, CO 81657
Office: 970.479.2139
Inspections:
inspections@vailgov.com
Construction
B18-0278
Issued: 08/21/2018
TOWN OF VAIL
Property Information
Address: 728 W LIONSHEAD CIR (210107223999) ( 210107223999 )
Unit #:
Parcel Number: 210107223999
Legal Description:
Contacts
Contact Type: Applicant
Full Name: Brian Judge
Address: Po Box 1734 105 Edwards Village Blvd Vail, CO 81658 Phone: 9709497034
Contact Type: Property Owner
Full Name: Ritz Carlton Common Area
Address: CO Phone: None
Contractor
Contractor Type: General
Company: Construction One
State License #: Phone: 6143780812
Project Information
Project Name: Ritz Carlton Lobby 2018
Project Description: Common Area/Lobby Finish Renovation
Fees Paid
Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$2,785.75
Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$1,810.74
Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$8,200.00
Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$700.00
Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$175.00
Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$525.00
Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$131.25
Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00
Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00
Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00
Total Paid:$14,342.74
Conditions
CONDITIONS UNDER WHICH PERMITS BECOME VOID:
If construction is not begun within 6 months from the date permit was issued.
If more than 5 months elapses between inspections.
If incorrect information is given on the application at the time the permit was issued.
Christopher Jarecki - Town of Vail Building Official
NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal
law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees.
PERMIT FEE RECEIPT
Case # B18-0278
Date Printed: 08/20/2018
TOWN OF VAIL - FEES RECEIPT
Permit Summary
Case Number: B18-0278 Status: Approved
Permit Number: Date Started: 06/29/2018
Permit Type: Construction Subcases Commercial
Lot Number: 2
Property: 728 W LIONSHEAD CIR (210107223999) (210107223999)
Contacts
Contact Type: Applicant
Company Name: J+A arch
Full Name: Brian Judge
Address: Po Box 1734 105 Edwards Village Blvd Vail, CO 81658
Email: brianj@judge-associates.com
Contact Type: Property Owner
Full Name: Ritz Carlton Common Area
Address: CO
Email: n/a
Permit Fees
Fee Information Account Amount
Permit Fee 001-0000.31111.00 $4,010.75
Construction Tax 110-0000.31060.00 $8,200.00
Will Call Fee 001-0000.31128.00 $15.00
Payment Information Date Paid Payment Type Amount
Permit Fee 08/20/2018 Check $4,010.75
Paid By: Marriott Vacations Worldwide - Notes: ck#1383227725
Construction Tax 08/20/2018 Check $8,200.00
Paid By: Marriott Vacations Worldwide - Notes: ck#1383227725
Will Call Fee 08/20/2018 Check $15.00
Paid By: Marriott Vacations Worldwide - Notes: ck#1383227725
FEE TOTAL $12,225.75
AMOUNT PAID $12,225.75
BALANCE DUE $0.00
08/20/2018 - 4:01:27 PM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657
1 / 1
Project:
Location:
Product Type:
Contact/Phone:
Model #:
Energy Controls
FF Series
FF Series
Commercial Series
The FF Series Commercial Auto-Off Timers are designed to replace
any standard wall switch - single or multi-gang. This series of
energy-efficient mechanical timers do not require electricity to
operate. In addition, they automatically limit the ON times for fans,
lighting, motors, heaters, and other energy consuming loads.
Features
r )PME GFBUVSF FOBCMFT UIF VTFS UP PWFSSJEF UIF BVUPNBUJD
shut-off function
r 3VHHFE UJNF EJBM QMBUF FBTJMZ XJUITUBOET UIF BCVTF FODPVOUFSFE JO
DPNNFSDJBM FOWJSPONFOUT
r $PNNFSDJBM iCSVTIFE NFUBMu Qlastic construction) look meets
NEC requirements
r 5JNF TBWJOH VQ GSPOU UFSNJOBM DPOOFDUJPO XJUI UFFUFSUZQF UFSNJOBMT
r 1SFTTPO LOPC EFTJHO FOTVSFT RVJDL BOE FBTZ JOTUBMMBUJPO
r $'- DPNQBUJCMF
Not for use with sunlamps, saunas, or loads that could cause
personal injury if timed incorrectly.
Ratings
3FTJTUJWF "NQ 7"$ )[
"NQ 7"$ )[
"NQ 7"$ )[
5VOHTUFO "NQ 7"$
.PUPS )1 7"$ )[
)1 7"$ )[
%JNFOTJPOT ) Y 8 Y %
FF15MC
FF30MHFF60MC
Auto-Off Timers
www.intermatic.com Energy Controls
FF Series
Model Number Time Cycle Switch Hold Color
FF5M .JOVUFT SPST No Brushed Metal Finish
FF5MH .JOVUFT SPST Yes Brushed Metal Finish
FF15MC .JOVUFT SPST No Brushed Metal Finish
FF15MH .JOVUFT SPST Yes Brushed Metal Finish
FF30MC .JOVUFT SPST No Brushed Metal Finish
FF30MH .JOVUFT SPST Yes Brushed Metal Finish
FF60MC .JOVUFT SPST No Brushed Metal Finish
FF60MHC .JOVUFT SPST Yes Brushed Metal Finish
FF2H )PVST SPST No Brushed Metal Finish
FF4H )PVST SPST No Brushed Metal Finish
FF6H )PVST SPST No Brushed Metal Finish
FF6HH )PVST SPST Yes Brushed Metal Finish
FF12HC )PVST SPST No Brushed Metal Finish
FF12HHC )PVST SPST Yes Brushed Metal Finish
FF315M .JOVUFT SPDT No Brushed Metal Finish
FF330M .JOVUFT SPDT No Brushed Metal Finish
FF360M .JOVUFT SPDT No Brushed Metal Finish
FF32H )PVST SPDT No Brushed Metal Finish
FF32HH )PVST SPDT Yes Brushed Metal Finish
FF34H )PVST SPDT No Brushed Metal Finish
FF34HH )PVST SPDT Yes Brushed Metal Finish
FF36H )PVST SPDT No Brushed Metal Finish
FF312H )PVST SPDT No Brushed Metal Finish
FF312HH )PVST SPDT Yes Brushed Metal Finish
FF415M .JOVUFT DPST No Brushed Metal Finish
FF430M .JOVUFT DPST No Brushed Metal Finish
FF460M .JOVUFT DPST No Brushed Metal Finish
FF46H )PVST DPST No Brushed Metal Finish
FF412H )PVST DPST No Brushed Metal Finish
Specification
5IF UJNFS TIBMM CF PG UIF BQQSPQSJBUF EJNFOTJPOT BOE EFTJHO UP QSPWJEF GPS EJSFDU SFQMBDFNFOU PG B TUBOEBSE XBMM TXJUDI
JO B TJOHMF HBOH EFFQ KVODUJPO CPY 5IF UJNFS TIBMM JODMVEF B TQJSBM UJNF TDBMF UP QSPWJEF FBTZ TFMFDUJPO PG B EFTJSFE
UJNF TFUUJOH .PMEFE XIJUF LOPC BOE CSVTIFE NFUBM àOJTI XBMM QMBUF TIBMM CF B QSFTTPO UZQF SFRVJSJOH OP TDSFX PS PUIFS
hardware to secure. The polymeric time dial shall replace a standard switch plate without modifications. The timer shall
IBWF B 6- MJTUFE SBUJOH PG
r )1 BU 7"$ )[
r )1 BU 7"$ )[
r "NQ 7"$ )[
r "NQ 7"$ )[
r "NQ 7"$ )[
r "NQ 7"$ 5VOHTUFO
5IF UJNFS àFME XJSJOH DPOOFDUJPOT TIBMM CF TFDVSFE CZ NFBOT PG B UFFUFSUZQF UFSNJOBM TDSFX UP QSPWJEF TFDVSF
DPOOFDUJPOT GPS BQQSPQSJBUF XJSF TJ[FT 5IF UJNFS TIBMM CF @@@@@@@@@@@ 4145%14541%5 5IF UJNFS @@@@@@@@@@ 4IBMM
4IBMM /PU IBWF B )PME GFBUVSF BOE TIBMM IBWF B UJNF DZDMF PG @@@@@@@@@@@4FF 5JNF $ZDMFT -JTUFE 5IF UJNFS TIBMM CF
*OUFSNBUJD NPEFM @@@@@@@@@@@@@@@4FF .PEFM /VNCFST -JTUFE
Energy Controls
FF Series
Diagrams
Example for SPST motor load control.
Example for SPST large motor load control
using a 3-pole contactor or motor starter.
Example for control of low voltage set-back
set-up thermostats using SPDT timer.
LOAD
LOAD
CR1
CR1
24VAC
Hot Neutral
Load 1Line 1
Load 1Line 1
Load 1
Jumper FromLine 2 To Line 1
Load 2
Line 1
Line 2
Hot Neutral
Hot Neutral
Load
Supply
55º
72º
STRIP
GAUGE
2.79"
1.60"
[7.09cm]
[4.06cm]
Example for 3-way load control providing
timed override from more than one location.
Example for reverse action control. The load
is switched off when timer is operated for a
limited time then switches back on.
Example for timed selection of low or high
speed motor with optional timer to limit
operation time regardless of speed selected.
Load 1
Load 2
Line 1
Optional Line 2
High
Low
NeutralHot
Load 2Line 2
No Connections Required
For Line 1 and Load 1
Hot
Load 1
Load 2
Line 1
Line 2Line 2
Hot Neutral
Neutral
Load 2
Line 1
Solder Pot
Jumper From
Line 2 To Line 1
Jumper From
Line 2 To Line 1
Jumper FromLine 2 To Line 1
LOAD
Example for controlling two loads
simultaneously by using DPST contacts.
Example for breaking both sides of a 240 volt
load using DPST contacts.
240 VAC
120 VAC
120 VAC
Line 1
Load 1
Load 2
Line 2
Hot Neutral
Line 1
Load 1
Load 2
Line 2 LOAD
LOAD