Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B18-0278_Approved Plans_1534860663.pdf
Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A0.0 H Cover Sheet And Index "G" 12.4.17: 75% CD Set "H"3.15.18: Building Permit "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set Judge + Architects + Planners Associates 728 West Lionshead Circle, Vail CO Lounge and Reception Renovation Ritz Carlton -Vail Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A0.2.1 H Construct. Egress Plan "E" 9.25.17: 25% CD Set "F" 11.28.17: BCER Review "G" 12.4.17: 75% CD Set "H"3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A0.2 H Main Level Egress Plan "E" 9.25.17: 25% CD Set "F" 11.28.17: BCER Review "G" 12.4.17: 75% CD Set "H"3.15.18 Building Permit 7.20.18: Plan Check Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S SSSSSSS SSSS S S SSSSSS SSSS S S S S SSSS SSSS SSheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A0.3 H Enlarged Fire Alarm, Exit and Device Plan "F" 11.28.17: BCER Review "G" 12.4.17: 75% CD Set "H"3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A0.4 H BCER Evaluation and Notes "E" 9.25.17: 25% CD Set "F" 11.28.17: BCER Review "G" 12.4.17: 75% CD Set "H"3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A2.0X H Existing Garage Plan "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H"3.15.18:Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 1245678 9101113121415163171717 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A3.0 H Proposed Main Level Floor Plan "F" 11.29.17: A/V Review "G" 12.4.17: 75% CD Set "H" 3.15.17:Building Permit "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A3.0D H Main Level Demo Plan "G" 12.4.17: 75% CD Set "H" 3.15.18:Building Permit "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A3.0E H Enlarged Proposed Main Level Floor Plan "G" 12.4.17: 75% CD Set "H" 3.15.18:Building Permit "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A3.0X H Existing First Level Plan "G" 12.4.17: 75% CD Set "H" 3.15.18:Building Permit "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A3.1 H Porte Cochere Plan "G" 12.4.17: 75% CD Set "H"3.15.18:Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A4.0XE H Enlarged Existing 2nd Floor Plan "H" 3.15.18:Building Permit "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 SSS SSSSSSSS SSS SSS S SSSSSS S SSS SS SS SSSSSSS Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A6.0 H Proposed RCP "H" 3.15.18:Building Permit "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S SSS SSSSSSSS SSS SSS S SSSSSS S SSS SS SS SSSSSSSheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A6.0E H Enlarged Proposed RCP "G" 12.4.17: 75% CD Set "H" 3.15.18: Building Permit "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "F" 11.29.17: A/V Review Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 SS S SSSSS SS S SS SSSSS SSSSSSSSSSSSSSSSSSSSS Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A6.0X H Existing RCP "H" 3.15.18: Building Permit "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S SS S SSSSS SS S SS SSSSS SSSSSSSSSSSSSSSSSSSSSheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A6.0XE H Enlarged Existing RCP "H" 3.15.18: Building Permit "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A6.1 H Proposed Porte Cochere RCP "G" 12.4.17: 75% CD Set "H"3.15.18: Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A6.2 H Garage RCP "G" 12.4.17: 75% CD Set "H" 3.15.18:Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A7.0 H Lounge Fireplace Plan/ RCP "G" 12.4.17: 75% CD Set "H"3.15.18:Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A7.1 H Lounge Fireplace Elevations/ Details "G" 12.4.17: 75% CD Set ³+´%XLOGLQJ 3HUPLW Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A7.2 H Fireplace Flue Routing Plans "G" 12.4.17: 75% CD Set ³+´%XLOGLQJ 3HUPLW Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 · · · · · · “ ” “ ” · Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A7.3 H Wall Section/ Fire Pit Details "G" 12.4.17: 75% CD Set ³+´%XLOGLQJ 3HUPLW 7.20.18: Plan Check Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 · · · Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A8.0 H Details, Wall Types and Doors "H" 3.15.18:Building Permit "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set 7.20.18: Plan Check Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 · · · Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A8.1 H Reception Desk Details "G" 12.4.17: 75% CD Set "H" 3.15.18:Building Permit 7.20.18: Plan Check Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S SS S S S S SS S S S S S S S S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A8.2 H Millwork Beam Key Plans "G" 12.4.17: 75% CD Set "H" 3.15.18:Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A8.3 H Millwork Beam Details "G" 12.4.17: 75% CD Set "H" 3.15.18:Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.0 H Reception 107: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.1 H Reception 107: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.10 H Lounge 117: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.11 H Private Lounge 118: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.12 H Private Lounge 118: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.2 H Reception 107: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.3 H Reception 107: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.4 H Library 116: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.5 H Library 116: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S S S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.6 H Lounge 117: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.7 H Lounge 117: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.8 H Lounge 117: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 S Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: A9.9 H Lounge 117: Interior Elevations "C" 07.10.17: 25% DD Set "D" 08.21.17: 75% DD Set "E" 9.25.17: 25% CD Set "G" 12.4.17: 75% CD Set "H" 3.15.18 Building Permit Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 08/21/18 RITZ-VAIL߰/߰VAIL,߰CO 15700߰PARKERHOUSE߰ROAD,߰SUITE߰300,߰PARKER,߰CO߰80134t 303/410-7047 ߰f߰303/410-7048denver.design@ xssentials.com ߰www.xssentials.com.RITZ-VAILVAIL,߰COAV0.0 08/21/18 15700߰PARKERHOUSE߰ROAD,߰SUITE߰300,߰PARKER,߰CO߰80134t 303/410-7047 ߰f߰303/410-7048denver.design@ xssentials.com ߰www.xssentials.com.RITZ-VAILVAIL,߰CO01 1.1 SCALE:߰3/32"=1'-0" ߰LEVEL߰1߰-߰DEVICE߰LOCATION߰PLAN AV1.1 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 AV3.0 H Proposed Audio/ Visual Plan "E" 9.25.17: 25% CD Set "F" 11.29.17: A/V Review "G" 12.4.17: 75% CD Set "H' 3.15.18: Building Permit 08/21/18 Sheet No: Project No: Revisions: Issue Dates: Seal Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 © 2017 Judge + Associates Architects + Planners Sheet Title: Judge + Architects + Planners Associates Ritz Carlton-VailLounge Renovation728 W Lionshead Circle, Vail, CO1619.00 AV3.1 H Proposed Audio/ Visual Notes "E" 9.25.17: 25% CD Set "F" 11.29.17: A/V Review "G" 12.4.17: 75% CD Set "H" 3.15.18:Building Permit 08/21/18 ' ' ISSUE LOG KEY: # DATEISSUE LOG ELECTRICAL SHEET INDEX TITLE ELECTRICAL COVER STREETE0.0 DESIGN DEVLOPMENT08.21.2017ISSUED AS PART OF A SET ' ' NOT PART OF SET ' ' ISSUED FOR INFORMATION ONLY* √ √ √ √ √ ELECTRICAL FIRST FLOOR PLAN - DEMOE2.0 LIGHTING FIRST FLOOR RCP - DEMOE3.0 GFCI DUPLEX RECEPTACLE DUPLEX RECEPTACLE; HALF SWITCHED ISOLATED GROUND DUPLEX RECEPTACLE WALL MOUNTED SPECIAL OUTLET AS NOTED SPECIAL OUTLET AS NOTED JUNCTION BOX WALL MOUNTED JUNCTION BOX FLOOR MOUNTED JUNCTION BOX DUPLEX RECEPTACLE MOUNTED ABOVE COUNTERC FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM DIVISION 15 EQUIPMENT POWER CONNECTION FUSED DISCONNECT NON FUSED DISCONNECT MOTOR STARTER ENCLOSED CIRCUIT BREAKER PULL BOX PUSH BUTTON TRANSFORMER PANELBOARD OR LOADCENTER CONTACTOR ELECTRIC MOTOR METER THERMOSTAT ATS AUTOMATIC TRANSFER SWITCH ONE-LINE DIAGRAM SYMBOLS CIRCUIT HOMERUN CONDUIT RUN CONDUIT RUN BELOW GRADE CONDUIT UP CONDUIT DOWN DISCONNECT SWITCH FUSE CIRCUIT BREAKER CURRENT TRANSFORMER POTENTIAL TRANSFORMER METER SURGE SUPPRESSION DEVICE VOLT-METER SELECTOR SWITCH GROUND GF GROUND FAULT PROTECTION AMP-METER ST SHUNT TRIP NORMALLY OPEN CONTACT NORMALLY CLOSED CONTACT COLD WATER GROUND CONNECTION BUILDING STEEL GROUND CONNECTION TIMER SWITCH MULTI-OUTLET PLUG STRIP TIME CLOCK PHOTO-CELL SWITCH THERMAL OVERLOAD SWITCH VARIABLE SPEED SWITCH KEY SWITCH LIGHTING FIXTURE SYMBOLS RECESSED LIGHTING FIXTURE WALL MOUNTED LIGHT WALL MOUNTED UP-LIGHT PENDANT MOUNTED LIGHT SURFACE MOUNTED LIGHT DIRECTIONAL/ADJUSTABLE RECESSED LIGHTING FIXTURE MONO-POINT LIGHTING FIXTURE RECESSED STEP LIGHT FLUORESCENT STRIP LIGHT WALL MOUNTED LINEAR FLUORESCENT LIGHT RECESSED OR SURFACE MOUNTED FLUORESCENT TROFFER FIXTURE WITH EMERGENCY BACKUP OR ON EM CIRCUIT WALL MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN EMERGENCY LIGHTS CEILING MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH DOOR JAMB SWITCH LIGHTING CONTROL SYMBOLS EXTERIOR POLE MOUNTED LIGHT EXTERIOR POST (BOLLARD) MOUNTED LIGHT DAYLIGHT PHOTO SENSORDL KEY SWITCH LV VARIABLE SPEED SWITCH DIMMER THREE-WAY DIMMER LOW VOLTAGE SWITCH WALL OCCUPANCY SENSOR/SWITCH THERMAL OVERLOAD SWITCH OCCUPANCY SENSOR - WALL MOUNTED OCCUPANCY SENSOR - CORRIDOR CEILING MOUNTED S S3 ST S O D 3 D SV SK SJ S4 SK SV ST S PC TC TS A V SS M T C T PB CB N -- J J J ABBREVIATIONSPOWER SYMBOLS SINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE NOTE: ALL SYMBOLS SHOWN ON LEGEND ARE NOT NECESSARILY USED.ELECTRICAL SYSTEMS LEGEND OS OS OCCUPANCY SENSOR - CEILING MOUNTED OS NOTES: · LIGHT LINEWEIGHT INDICATES EXISTING. · HATCHED AREAS INDICATE DEMOLITION. · 'C' ADJACENT TO A DEVICE INDICATES MOUNTING ABOVE COUNTERTOP. AFC AFF AFG AHJ - ABOVE FINISHED CEILING - ABOVE FINISHED FLOOR - ABOVE FINISHED GRADE - AUTHORITY HAVING JURISDICTION AL - ALUMINUM AWG AP - ACCESS POINT - AMERICAN WIRE GAUGE BFG BMS BAS - BUILDING AUTOMATION SYSTEM - BELOW FINISH GRADE - BUILDING MANAGEMENT SYSTEM C CATV CCTV - CONDUIT - COMMUNITY (CABLE) ANTENNA TELEVISION SYSTEM - CLOSED CIRCUIT TELEVISION CKT - CIRCUIT CPU - CENTRAL PROCESSING UNIT CT - CURRENT TRANSFORMER DISP - GARBAGE DISPOSAL DW - DISHWASHER (E) - EXISTING EM - EMERGENCY EWC - ELECTRIC WATER COOLER FBO GFI FA FACP GRD GC - FIRE ALARM - FIRE ALARM CONTROL PANEL - FURNISHED BY OTHERS - GENERAL CONTRACTOR - GROUND FAULT CIRCUIT INTERRUPTER - GROUND IAW IN ACCORDANCE WITH- IC IDF IG IR LAN - INTERMEDIATE CROSS-CONNECT - INTERMEDIATE DISTRIBUTION FRAME - ISOLATED GROUND - INFRARED - LOCAL AREA NETWORK NIC MDF (N) MAIN DISTRIBUTION FRAME- NEW- NOT IN CONTRACT- NL NIGHT LIGHT- NTS NOT TO SCALE- OC PA ON CENTER- PUBLIC ADDRESS- REF REFRIGERATOR- TVSS TTB TELECOMMUNICATIONS TERMINAL BOARD- TRANSIENT VOLTAGE SURGE SUPPRESSOR- TVTB TELEVISION TERMINAL BOARD- UG UNO W V UNDERGROUND- UNLESS NOTED OTHERWISE- VOLT- WATT- WP XP WAN WLAN WAP WIDE AREA NETWORK- WIRELESS ACCESS POINT- WIRELESS LOCAL AREA NETWORK- WEATHERPROOF- EXPLOSIONPROOF- +18" DEVICE ABOVE FINISH FLOOR (VERIFY W/ ARCH ELEVS) MOUNTING HEIGHT TO CENTERLINE OF- C ELECTRICAL FIRST FLOOR PLAN - NEWE2.1 LIGHTING FIRST FLOOR RCP - NEWE3.1 √ ELECTRICAL DIAGRAMS E4.0 √ GENERAL NOTES: 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK. 2. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. 3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER - IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. 4. SERVICE SHALL BE MAINTAINED TO EXISTING AREAS DURING CONSTRUCTION. CONTRACTOR SHALL PROVIDE PORTABLE GENERATORS, CABLES, OUTLETS, ETC. AS REQUIRED TO MAINTAIN CONTINUITY OF SERVICE. PLACEMENT OF SUCH PORTABLE EQUIPMENT SHALL BE SUBJECT TO OWNER APPROVAL. 5. REVIEW ARCHITECTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID. 6. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 7. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND ORDINANCES. 8. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 9. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS. 10. EXISTING SYSTEMS AND CONDITIONS SHOWN ON DRAWINGS FOR EXISTING BUILDINGS ARE TO BE NOTED “FOR GUIDANCE ONLY”. THE ELECTRICAL CONTRACTOR TO FIELD CHECK ALL EXISTING CONDITIONS PRIOR TO BIDDING AND TO INCLUDE IN HIS BID AN ALLOWANCE FOR REMOVAL AND/OR RELOCATION OF EXISTING CONDUITS, WIRES, DEVICES, FIXTURES, OR OTHER EQUIPMENT AS INDICATED ON THE PLANS OR AS REQUIRED TO COORDINATE AND ADAPT NEW AND EXISTING ELECTRICAL SYSTEM TO ALL OTHER WORK AS REQUIRED 11. PROVIDE ELECTRICAL DEMOLITION REQUIRED. REFER TO ARCHITECTURAL AND ELECTRICAL DEMOLITION DRAWINGS FOR LOCATION AND EXTENT OF DEMOLITION REQUIRED. CONTRACTOR SHALL VISIT SITE PRIOR TO BID TO DETERMINE EXTENT OF WORK INVOLVED. 12. PROVIDE ALL NECESSARY DEMOLITION TO REMOVE EXISTING UNUSED CONDUIT, WIRE, CABLE, J-BOXES, RECEPTACLES, SWITCHES, LIGHTS, FIRE ALARMS DEVICES, ETC. COMPLETE WITH ASSOCIATED CIRCUITING TO SOURCE. WHERE IT IS NOT FEASIBLE TO REMOVE THE ABOVE, OUTLET SHALL BE ABANDONED, WIRE REMOVED, AND BLANK COVER PLATES PROVIDED. 13. ALL (E) EQUIPMENT, LAMPS, BALLASTS, ETC. BEING REMOVED SHALL BE DISCARDED IN ACCORDANCE WITH APPLICABLE EPA REQUIREMENTS. 14. EXISTING LIGHT FIXTURES, ELECTRICAL EQUIPMENT, ETC. BEING REMOVED SHALL BE RETURNED TO THE OWNER, EXCEPT FOR THOSE ITEMS BEING RELOCATED. 15. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN. 16. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION. 17. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED. 18. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 19. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. 20. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 20 AMPERES FOR DUPLEX RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT. 21. ALL WIRING SHALL BE INSTALLED IN LISTED METALLIC RACEWAYS, UNLESS NOTED OTHERWISE. CONNECTORS SHALL BE INSULATED THROAT TYPE. MINIMUM RACEWAY SIZE IS 3/4”. ALL FEEDERS SHALL BE INSTALLED IN RACEWAY CONFIGURATIONS SHOWN ON ONE-LINE. BRANCH CIRCUITS 25A AND LARGER SHALL BE INSTALLED IN INDIVIDUAL RACEWAYS. BRANCH CIRCUITS 20A AND SMALLER MAY BE GROUPED INTO RACEWAYS AS TO NOT EXCEED 6 CURRENT-CARRYING 75-DEGREE CONDUCTORS, OR 9 CURRENT-CARRYING 90-DEGREE CONDUCTORS, IN A SINGLE RACEWAY. METAL CLAD CABLE IS PERMITTED. 22. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUAL, AND SHALL BE IDENTIFIED AT ALL JUNCTION, PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT, ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. 23. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. 24. PROVIDE NEW UPDATED PANELBOARD DIRECTORIES FOR EXISTING AND NEW CIRCUITS BEING UTILIZED FOR COMPLETION OF PROJECT. 25. PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS. 26. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVED FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT. 27. FIRE ALARM, SOUND, TELEPHONE, COMPUTER AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1” SHALL HAVE LONG RADIUS SWEEPS (12 TIMES THE DIAMETER). 28. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER. 29. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 30. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE.DESIGN DEVLOPMENT√ √ √ √ √ √09.25.2017LESS THAN 50% OF THE LUMINAIRES IN THE SCOPE OF WORK ARE BEING REPLACED AND ENERGY USE IS NOT INCREASED WHICH COMPLIES WITH EXCEPTION #7 IN C503.1 OF THE 2015 IECC. LOAD BEING REMOVED FROM PANEL 'L11': RECEPTACLES 1,620 VA LOAD BEING ADDED FROM PANEL 'L11': RECEPTACLES 1,440 VA FIRE PITS (x2) 360 VA FIREPLACE 6,656 VA TOTAL 8,456 VA 19 AMPS OF LOAD ADDED AT 208Y/120V, 3-PHASE.BUILDING PERMIT√ √ √ √ √ √ LIGHTING PORTE COCHERE RCP - DEMOE3.2 √ LIGHTING PORTE COCHERE RCP - NEWE3.3 √03.15.2018PANEL: (E) L11 - SEC. 1 VOLTAGE: 120/208V, 3PH, 4W MINIMUM BUS: 125 LOCATION: ELEC ROOM 110 MAIN: MLO MOUNTING: SURFACE MINIMUM AIC: - NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B C POLE TRIP A B C TRIP POLE A B C 1 L (E)WRK RM 103 1 20 + 40 2 E (N)LOUNGE FP 2 3 SPARE 1 20 + -- -- E -- 4 5 SPARE 1 20 + 20 1 R (N)AV 6 7 R (E)WRK RM 103 N&W/TEF-1 163 1 20 + 20 1 SPARE 8 9 R (E)WRK RM 103 S 1 20 + 20 1 SPARE 10 11 R (E)WRK RM 103 S&W 1 20 + 20 1 SPARE 12 13 SPARE 1 20 + 20 1 R (E)ELEV LOBBY 122 14 15 R (E)TRSH RM/AUTO DOOR 1 20 + 20 1 R (E)CORRIDOR 139 16 17 R (E)ELEV LOBBY/ AUTO DOOR 1 20 + 20 1 R (E)PANTRY 120 S 18 19 R (E)LOUNGE 117 EAST 1 20 + 20 1 R (E)LOUNGE 117 N 20 21 R (E)PRIV LOUNGE 118 E 1 20 + 20 1 R (E)LIBRARY 116 W 22 23 R (E)CORRIDOR 109 1 20 + 20 1 R (E)LIBRARY 116 W&S 24 25 R (E)CORRIDOR 111 1 20 + 20 1 E (N)WEST FIRE PIT 26 27 R (E)RECEPTION 105 W 1 20 + 20 1 E (N)EAST FIRE PIT 28 29 SPARE 1 20 + 20 1 R (N)LIBRARY TV 30 31 R (E)ELECT RM 110 E 1 20 + 20 1 R (N)LIBRARY TV 32 33 SPARE 1 20 + 20 1 R (N)LIBRARY TV 34 35 SPARE 1 20 + 20 1 SPARE 36 37 SPARE 1 20 + 20 1 SPARE 38 39 SPARE 1 20 + 20 1 SPARE 40 41 SPARE 1 20 + 20 1 SPARE 42 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. EXISTING LOADS NOTED WITH (E). (L) LIGHTING 0 0 0 125% 0 B. NEW LOADS NOTED WITH (N). (R) RECEPTACLES 0 0 0 NEC 220 0 C. (LM) LARGEST MOTOR 0 0 0 25% 0 D. (M) MOTORS (ALL) 0 0 0 100% 0 E. (E) EQUIPMENT 0 0 0 100% 0 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 0 (1) PANEL TOTAL (KVA): 0.0 (2) (3) PANEL TOTAL (A): 0 (4) (5) ELECTRICAL SPECIFICATIONSE0.1 √ Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E0.0.DWG03.15.184:51:23 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: 100% Construction DocumentsALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL COVER SHEET BAS MAS E0.0 08/21/18 ELECTRICAL SPECIFICATIONS: DIVISION 26 - ELECTRICAL SPECIFICATIONS SECTION 26010--GENERAL PROVISIONS: PART 1 - GENERAL 1.01 PROJECT DESCRIPTION A.This project is a remodel and addition of a commercial building. The project is approximately 5,300 square feet located at 728 W. Lionshead Circle in Vail, Colorado. 1.02 PROVISIONS A.Work performed under this division of the specifications shall conform to the requirements of Division 1, and the electrical drawings and all items hereinafter specified. 1.The drawings and specifications for the electrical work are intended to describe a complete electrical system; omission of minor items obviously necessary to accomplish the above intent shall not relieve the Contractor from providing same. 2.Prior to any work being performed under this division examine architectural, mechanical, and interior design drawings and specifications and if any discrepancies occur between them and the electrical drawings and specifications, report same to the Architect in writing and obtain written instructions for the work. 3.Electrical drawings are diagrammatic but shall be followed as closely as actual construction of the building will permit. All changes from drawings necessary to make the electrical work conform to the building as constructed shall be made without cost to the Owner. 4.Coordinate the electrical work with the General Contractor and be responsible to him for satisfactory progress of same. Coordinate electrical work with all other trades on the project without cost to the Owner. 5.Do not scale drawings. Verify dimensions on architectural drawings and in field prior to commencement of work. 6.All work and materials covered by drawings and specifications shall be subject to review at any time by representatives of the Architect and Owner. If the Architect or Owner's agent finds any material or installation that does not conform to these drawings and specifications, Contractor shall remove the material from the premises and correct the installation to the satisfaction of the agent. 7.In acceptance or rejection of installed electrical systems, no allowance will be made for lack of skill on the part of the installers. 1.03 WORK INCLUDED A.The electrical system required for this work to include, but is not necessarily limited to: 1.Complete branch circuit wiring for lighting, motors, receptacles, junction boxes, and similar uses. 2.Lighting fixtures, wall switches, receptacles and similar items. 3.Electrical requirements for fireplace, if applicable. 4.Power Owner furnished equipment. 1.04 CODES AND STANDARDS A.The latest editions of the following standards (including supplements and official interpretations) are minimum requirements: 1.NFPA 70 - National Electrical Code (NEC). 2.NFPA 72 - National Fire Alarm Code. 3.NFPA 101 - Life Safety Code. 4.NFPA 110 - Emergency Power Systems 5.Conform to all applicable State and Local Codes. 6.American National Standards Institute (ANSI). 7.National Electrical Safety Code (NESC). 8.Americans with Disabilities Acts (ADA) and American National Standards Institute (ANSI) 117. 9.National Electrical Manufacturer's Association (NEMA). 10.Underwriter's Laboratories (UL). 11.Insulated Cable Engineers Association (ICEA). 12.International Building Code. 13.International Mechanical Code. 14.International Fire Code. 15.Institute of Electrical and Electronic Engineers (IEEE). 16.Sheet Metal and Air Conditioning Contractors National Association (SMACNA). B.Comply with requirements of Underwriters Laboratories for all items installed for which U.L. standards have been established. C.The drawings and specifications take precedence when they are more stringent than codes, statutes, or ordinances in effect. Applicable codes, ordinances, standards and statutes take precedence when they are more stringent or conflict with the drawings and specifications. 1.05 EXAMINATION OF BIDDING DOCUMENTS A.Each bidder shall examine the bidding documents carefully, and not later than seven days prior to the date of receipt of bids, shall make written request to the Architect for interpretation or correction of any discrepancies, ambiguities, inconsistencies, or errors therein which he may discover. The Architect will issue any interpretation or correction as an Addendum. Only a written interpretation or correction by addendum shall be binding. No bidder shall rely upon interpretations or corrections given by any other method. If discrepancies, ambiguities, inconsistencies, or errors are not covered by addendum or written directive, Contractor shall include in his bid, labor, materials and methods of construction resulting in higher cost. After award of contract, no allowance or extra compensation will be made on behalf of the Contractor due to his failure to make the written requests as described above. B.Failure to request clarification during the bid phase of any inadequacy, omission, or conflict will not relieve the Contractor of their responsibilities. The signing of the contract will be considered as implicitly denoting that the Contractor has a thorough comprehension of the full intent and scope of the working drawings and specifications. 1.06 EXAMINATION OF PREMISES A.Visit site prior to bid and verify that conditions are as indicated. Contractor shall include in his bid costs required to make his work meet existing conditions. 1.07 EXISTING CONDITIONS A.Existing systems and conditions shown on drawings for existing buildings are to be noted "for guidance only". The Electrical Contractor shall field check all existing conditions prior to bidding and is to include in his bid an allowance for extension, removal and/or relocation of existing conduits, wires, devices, fixtures, or other equipment as indicated on the plans or as required to coordinate and adapt new and existing electrical system to all other work. B.Where the reuse of existing conduits, wires, devices, etc. is permissible, make certain that the wiring for same is continuous from outlet to outlet and that such circuit or systems shall pass through no outlet or junction boxes which may be rendered inaccessible by the structural changes to be made to the building. Existing conduits, wire, devices, etc. which are not indicated for reuse shall become the property of this Contractor however lighting fixtures, panel fused switches, circuit breakers, fire alarm equipment, etc. shall become the property of the Owner. C.System outages shall be permitted only at times approved by Owner in writing. Work which could result in an accidental outage (beyond branch circuits) shall be performed with the Owner's maintenance personnel advised of such work. D.Service shall be maintained to existing areas during construction. Contractor shall provide portable generators, cables, outlets, etc. as required to maintain continuity of service. Placement of such portable equipment shall be subject to Owner approval. Generator system shall be complete and operable and shall include required accessories, fuel tanks, piping, muffler, block heater, battery charger, etc. E.Immediately after award of contract, verify available physical space and ampacity of existing panelboards, switchboards, distribution boards, motor control centers, etc., and provide written documentation of findings to the Architect/Engineer. Documentation shall include a minimum 24-hour recording ampere reading on all existing switchgear being utilized for this project. F.Provide new updated panelboard directories for existing and new circuits being utilized for completion of project. 1.08 PERMITS, FEES & NOTICES A.Obtain and pay for all necessary permits, inspections and certificates that may be necessary for the full completion of the work. Furnish the Architect with a certificate of final inspection and approval from the AHJ over the electrical installation. B.Notify proper authorities when work is ready for inspections required by applicable codes, rules and regulations, allowing sufficient time for inspections to be made without hindering progress of the work. Furnish to the Owner copies of inspection certificates of acceptance. 1.09 TESTS A.Upon completion of all work and adjustment of all equipment, provide complete operational tests of all electrical equipment provided under this division. 1.10 WARRANTY A.Guarantee that all work governed by this division shall be free of defects in workmanship, materials and parts for a period of one (1) year after written acceptance. Promptly repair, revise, and replace defects as directed with no additional cost to the Owner (lamps and fuses are exempt). 1.11 RECORD DRAWINGS A.During the progress of the work, maintain an accurate record of the installation of the electrical system. Upon completion of the electrical installation, transfer all record data to prints of the original drawings. Drawings shall include all addendum items, change orders, alternates, reroutings, etc. As a condition of acceptance of the project, deliver to the Architect one copy of the record drawings. 1.12 PROTECTION A.Of People: Arrange barriers, signs, etc. as required to minimize the hazard of people. Comply with applicable safety and health regulations. Coordinate as necessary with the Owner and the General Contractor. B.Of Work: Take all measures necessary to protect the work both before and after installation, to assure that it will be in clean, undamaged, unblemished condition when turned over to the Owner. Repair/replace work damaged during construction. PART 2 - PRODUCTS 2.01 STANDARD FOR MATERIALS A.All electrical material shall be new and of the quality and type specified. B.Manufacturer and catalog number shown in these specifications or on drawings are intended as a guide to quality. Equivalent materials and equipment of other manufacturers will be considered provided such substitutions are requested in accordance with the provisions of paragraph 2.03 and shall include all information necessary to support the claim of equivalency. C.No extension of completion date shall be allowed for time lost in consideration, shipping, or installation of approved substitutions. Review of substitutions signifies general equality of materials and equipment only. This review does not relieve the Contractor of responsibility for proper operation of the system, compliance with specifications and necessary changes due to dimensional differences or space requirements. 2.02 PRODUCT HANDLING A.Use all means necessary to protect electrical system materials before, during and after installation and to protect the installed work and materials of all other trades. B.In the event of damage, immediately make all repairs and replacements necessary to the approval of the Architect at no additional cost to the Owner. C.Upon completion of all installations, lamping and testing, thoroughly inspect all exposed portions of the electrical installation and completely remove all exposed labels, soil, markings, and foreign materials. PART 3 - EXECUTION 3.01 WORKMANSHIP AND COMPLETION OF INSTALLATION A.Contractor's personnel and subcontractors selected to perform the work shall be well versed and skilled in the trades involved. B.Coordinate electrical equipment and materials installation with other building components. C.Sequence, coordinate, and integrate installations of electrical materials and equipment for efficient flow of the Work. Give particular attention to large equipment requiring positioning prior to closing-in the building. D.Any changes or deviations from the drawings and specifications must be accepted in writing by the Architect/Engineer. All errors in installation shall be corrected at the expense of the Contractor. All specialties shall be installed as detailed on the drawings. Where detail or specific installation requirements are not provided, manufacturer's recommendations shall be followed. E.Upon completion of work, all equipment and materials shall be installed complete, thoroughly checked, correctly adjusted, and left ready for intended use or operation. All work shall be thoroughly cleaned and all residue shall be removed from surfaces. Exterior surfaces of all material and equipment shall be delivered in a perfect, unblemished condition. F.Contractor shall provide a complete installation, including all required labor, material, cartage, insurance, permits, and taxes. 3.02 PROGRESS OF WORK A.Order the progress of electrical work to conform to the progress of the work of the other trades. Complete the entire installation as soon as the condition of the building will permit. Any cost resulting from defective or ill-timed work performed under this Section shall be borne by this Contractor. 3.03 CUTTING AND PATCHING A.Provide all cutting, trenching, backfilling, patching and refinishing or resurfacing required for electrical work in a manner meeting the approval of the Engineer and at no additional cost to the Owner. B.All openings made in fire-rated walls, floors, or ceilings shall be patched and made tight in a manner to conform to the fire rating for the surface penetrated. 3.04 DELIVERY AND STORAGE OF MATERIALS A.Arrange and be held responsible for delivery and safe storage of materials and equipment for electrical installation. B.Carefully check materials furnished to this Contractor for installation, and provide receipt acknowledging acceptance of delivery and condition of the materials received. Thereafter, assume full responsibility for its safekeeping until the final installation has been reviewed and accepted. 3.05 PROTECTION OF WORK AND PROPERTY A.Where there are existing facilities, be responsible for the protection thereof, whether or not such facility is to be removed or relocated. Moving or removing any facility must be done so as not to cause interruption of the work of Owner's operation. B.Close all conduit openings with caps or plugs during installation. Cover all fixtures and equipment and protect against injury. At the final completion, clean all work and deliver in an unblemished condition, or refinish and repaint at the discretion of the Architect. C.Any equipment or conduit systems found to have been damaged or contaminated above “MILL” or “SHOP” conditions shall be replaced or cleaned to the Engineer's satisfaction. 3.06 FINAL ACCEPTANCE A.Final acceptance by the Owner will not occur until all operating instructions are received and Owner's personnel have been thoroughly indoctrinated in the maintenance and operation of all equipment. B.Operating manual, parts lists, and indoctrination of operating and maintenance personnel: Furnish the services of a qualified representative of the supplier for each item or system itemized below who shall instruct specific personnel, as designated by the Owner, in the operation and maintenance of that item or system. C.Deliver three (3) complete operating manuals and parts lists to the Owner (or his designated representative) at the time of the above required indoctrination. Fully explain the contents of the manuals as part of required indoctrination and instruct the Owner's personnel in the correct procedure in obtaining service, both during and after the guarantee period. The operating manual and parts lists shall give complete information as to whom the Owner shall contact for service and parts, including the address and phone number. Furnish evidence that an authorized service organization regularly carries a complete stock of repair parts for these items (or systems), and that the organization is available for service. Service shall be furnished within twenty four (24) hours after requested. D.Clean up: Remove all materials, scrap, etc., relative to the electrical installation and leave the premises and all equipment, lamps, fixtures, etc. in a clean, orderly condition. Any costs to the Owner for clean up of the site will be charged against the Contractor. E.Acceptance Demonstration: Upon completion of the work, at a time to be designated by the Architect, the Contractor shall demonstrate for the Owner the operation of the entire installation, including all systems provided under this contract. F.Operating and Acceptance Tests: Provide all labor, instruments, and equipment for the performance of tests as specified. Submit three (3) copies of a typewritten test report for the Architect for his approval. 1.Record the full load current in each phase or line at the main service entrance and for each feeder leaving the main distribution panelboard. Readings shall be taken with the maximum installed load connected and in operation. 2.Perform a careful inspection of the main switchboard bus structure and cable connections to verify that all connections are mechanically and electrically tight. 3.Measure the resistance to ground for the service ground, which shall not exceed ten (10) ohms under normal soil moisture conditions. If required, install additional ground provisions in a manner accepted by the Engineer at no additional cost to the Owner. 3.07 IDENTIFICATION A.General: Provide the following services and materials to assist the Owner in operation and maintenance. B.Directory Cards, Nameplates and Labels: No temporary markings, which are visible on equipment, shall remain after the project is complete. Repaint trims, housing, etc., where such markings cannot be readily removed. Defaced finishes must be refinished. All engraved metal or plastic nameplates shall be white letters on a black or gray background. Raised letter type tape shall not be used. No abbreviations in labeling will be permitted without special approval. All panelboards shall be labeled as designated on the electrical drawings. Thoroughly clean surface to which pressure sensitive type labels are applied to assure adherence of label. Directory cards, nameplates, and labels shall indicate the general area and type of electrical load served by each circuit. Provide the following types of labels at these locations. 1.For all branch circuit panelboard directories, provide neatly typed, removable cards and protective plastic faces. Spare circuit breakers shall be identified as such. 3.08 CONSTRUCTION LIGHTING AND POWER A.Provide all temporary facilities required to supply construction power and light. Install and maintain facilities in a manner that will protect the public and workmen. Comply with all applicable laws and regulations. B.The General Contractor shall pay for all power and light used by him and his subcontractors where construction power is separately metered, or is taken from the permanent project metered service solely for construction use. 3.09 REMODELING PROVISIONS A.Existing systems and conditions shown on the drawings are provided for guidance only. The Electrical Contractor shall field check all existing conditions prior to bidding and shall include in his bid an allowance for the removal and relocation of existing conduits, wires, devices, fixtures, or other equipment as indicated on the plans or as required to coordinate and adapt new and existing electrical systems to all other work required for this project. B.Where the reuse of existing conduits, outlets, junction boxes, etc., is permissible, make certain that the wiring form them is continuous from outlet to outlet. Provide modifications to assure that circuits, or system, shall not pass through outlets or junction boxes which may be rendered inaccessible by changes to be made to the building. Existing conduits, wire, devices, fixtures, etc., which shall be removed shall become the property of this Contractor unless otherwise noted. C.Connect new work to existing in a manner that will assure proper raceway grounding throughout in conformance with the National Electrical Code. D.Remodel Work Cutting and Patching: The Contractor shall perform cutting, channeling, chasing, drilling, etc., as required to install or remove electrical equipment in areas of remodeling. This work shall be performed so as to minimize damage to portions of wall finishes, surfaces, plastering, or the structure which are to be reused, resurfaced, plastered or painted under another division of these specifications. E.Carefully coordinate with the required remodeling work, cutting and patching etc., performed by the other trades. Remove or relocate existing electrical conduits, wires, devices, fixtures and other equipment as necessary. F.All outages on portions of existing electrical systems shall be minimized and shall be at a time and of duration as accepted by the Owner. 3.10 ELECTRICAL DEMOLITION A.Examination 1.Verity field measurements and circuiting arrangements are as shown on drawings. 2.Verify that abandoned wiring and equipment serve only abandoned facilities. 3.Demolition drawings are based on casual field observation and existing record documents. Report discrepancies to Architect before disturbing existing installation. 4.Beginning of demolition means installer accepts existing conditions. B.Preparation 1.Disconnect electrical systems in walls, floors, and ceilings scheduled for removal. 2.Coordination outages with Architect/Owner. 3.Provide temporary wiring and connections to maintain existing systems in service during construction. When work must be performed on energized equipment or circuits, use personnel experienced in such operations. 4.Fire protection, fire alarm, and detection systems shall be maintained and capable of proper operation during construction. The local Fire Marshall shall be notified before construction starts, when scheduled interruptions are expected and after construction is complete. Protect and support life safety systems routed through areas of demolition. 5.Existing telephone system: Maintain existing system in service. Disable system only to make switchovers and connections. Notify Owner/Architect in writing at least 24 hours before partially or completely disabling system. Minimize outage duration. C.Demolition and Extension of Existing Electrical Work 1.Demolish and extend existing electrical work under provisions of Division 1, Division 2, and this section. 2.Remove, relocate, and extend existing installations to accommodate new construction. 3.Remove abandoned wiring to source of supply. 4.Remove exposed abandoned conduit, including abandoned conduit above accessible ceiling finishes. Cut conduit flush with walls and floors, and patch surfaces. 5.Disconnect abandoned outlets and remove devices. Remove abandoned outlets if conduit servicing them is abandoned and removed. Provide blank cover for abandoned outlets, which are not removed. 6.Disconnect and remove electrical devices and equipment serving utilization equipment that has been removed. 7.Disconnect and remove abandoned luminaires. Remove brackets, stems, hangers, and other accessories. 8.Repair adjacent construction and finishes damaged during demolition and extension work. 9.Maintain access to existing electrical installations, which remain active. Modify installation or provide access panel as appropriate. 10.Extend existing installations using materials and methods compatible with existing electrical installation, or as specified in individual section. D.Cleaning and Repair 1.Clean and repair existing materials and equipment, which remain or are to be reused. 2.Panelboards: Clean exposed surfaces and check tightness of electrical connections. Replace damaged circuit breakers and provide closure plates for vacant positions. Provide typed circuit directory showing revised circuiting arrangement. 3.Luminaries: Remove existing luminaires for cleaning. Use mild detergent to clean all exterior and interior surfaces; rinse with clean water and wipe dry. Replace lamps, non-operational ballasts, and broken electrical parts. E.Installation 1.Install relocated materials and equipment under the provisions of Division 1. END OF SECTION 26010 SECTION 26100--BASIC MATERIALS AND METHODS PART 1 - GENERAL (Not Used) PART 2 - PRODUCTS 2.01 RACEWAYS AND FITTINGS A.Conduit: 1.Conduits installed underground or in grade slabs shall be Schedule 40 PVC with ground wire. 2.Conduits subject to mechanical damage or where otherwise required by code shall be galvanized rigid heavy wall conduit; all other conduit may be electric metallic tubing. 3.Flexible metallic conduit shall be used where vibration or other reasons do not allow solid connections to motors, equipment, etc. Flex may also be used to fish in existing walls or where required to connection in millwork. The use of flex shall be held to a minimum. Where flexible metallic conduit is used in areas subject to moisture, PVC-coated flex (Liquidtight) shall be used. B.Fittings: 1.Use solvent welded fittings for all PVC conduit. 2.Use set-screw or compression fittings for all EMT conduit. 3.Use threaded fittings for all rigid conduit. 2.02 WIRE AND CABLE A.Voltage range 0 to 24: High conductivity copper, thermo-plastic insulation, 300 volt rating. B.Voltage range 24 to 600: High conductivity copper, moisture-resistant thermo-plastic insulation, 600 volt 75°C rating for general use. For HID fixtures and wiring within 3 inches of fluorescent ballasts, wire shall be copper, minimum 90°C rated. Sizes indicated are for installation in a maximum 30°C ambient. Conductor ampacity shall be derated for higher ambient installations. C.Conductors used specifically for equipment or service ground may be bare or have insulation to match circuit/feeder conductors. 2.03 WIRE CONNECTIONS A.All electrical connections shall be electrically and mechanically secure, using the following methods: 1.Wire size #8 and smaller--pressure type connectors (scotch-lok) or equivalent. 2.Wire size #6 and larger--mechanical or compression lugs, Burndy, T & B, Ilsco or equivalent. B.Wire termination provisions for panelboards, circuit breakers, safety switches, and all other electrical apparatus shall be listed as suitable for 75°C. 2.04 SURFACE RACEWAYS A.Surface Metal Raceways: Galvanized steel with snap-on covers. Manufacturers standard enamel finish in color selected by Architect. B.Manufacturer shall be Thomas& Betts Corporation, Walker systems, Inc. (The Wiremold Company), or approved equal. 2.05 OUTLET BOXES A.Outlet boxes shall be: one piece steel, galvanized, Steel City Electric, Appleton Electric, Raco or approved equivalent. Where NMC or ENT is used, plastic boxes are acceptable. 2.06 DEVICES A.Wiring devices shall be specification grade and rated at 20 amperes for light switches and 20 amperes for duplex receptacles. Switches, receptacles, and other devices shall be Leviton Decora style, or Pass Seymour, Cooper, or Hubbell equivalent. Color shall be ivory unless noted otherwise by Architect. B.Wall Switch Occupancy Sensors: 120/277V, adjustable time delay up to 20 minutes, 180 degree field of view switch a minimum coverage area of 300 square feet. C.Wall plates shall be smooth, high-impact thermoplastic material for finished spaces. D.Poke Through Assemblies shall be factory fabricated-and-wired assembly of below floor junction box with multi-channeled, through-floor raceway/firestop unit and detachable matching floor service outlet assembly. Provide four simplex receptacles and space for four RJ-45 jacks, selected to fit nominal 3-inch cored hole in floor and matched to floor thickness. Unit shall be listed and labeled for fire rating of floor-ceiling assembly. E.Multi outlet assemblies shall be aluminum 3” high, divided channel raceway for use as a complete matching assembly. Duplex 20 amp receptacles shall be located every 18” or as shown in drawings. Route #12AWG minimum. Derate conductors as required by NEC. PART 3 - EXECUTION 3.01 CONDUIT INSTALLATION A.All wiring shall be installed in listed metallic raceways. Raceways in slab-on-grade or below grade shall be schedule 40 PVC. Transitions from below to above grade shall be with rigid steel elbows with P.V.C. Jacket or approved equal protection. EMT fittings shall be malleable iron or steel. Connectors shall be insulated throat type. B.Make conduit bends with standard conduit elbows or conduit bent to not less than the same radius. All bends shall be free from dents or flattening. C.All fittings in wet places, locations exposed to weather, or buried in masonry, concrete or fill, shall be water-tight. Apply listed compound to threads of raceway and fittings before making up joints. Follow compound manufacturer's instructions. D.At locations subject to moisture or vibration, use insulating bushings to protect conductors, including conductors smaller than No. 4 AWG. E.Cap conduit ends to prevent entrance of foreign materials during construction. F.Run concealed conduits in a direct line. Run exposed conduits parallel to, or at right angles with, lines of the building. Install all conduits at least 6" away from flues, steam and hot water pipes. Install horizontal raceway runs above water and steam piping. G.Run underground conduits a minimum of 2' 0" below grade. H.Seal all conduit penetrations of fire rated walls, floor, or ceilings with U.L. listed "Dow Corning" #2000 or #2001 fire stop sealant or equivalent. I.All empty raceway systems shall have a polypropylene pullwire or equal, and shall be identified at all junction, pull and termination points using permanent metallic tags. Tag shall indicate intended use of conduit, origination, and termination points of each individual conduit. J.Non-metallic and flexible metal conduits shall have a code-sized copper grounding conductor. Increase conduit size as required. K.Conduits penetrating through roof shall have roof flashing with caulk type counter flashing sleeve. Installation shall be watertight. L.Where panels are installed flush with walls, empty conduits shall be extended from the panel to an accessible space above or below. A minimum of one 3/4"c shall be installed for every three single pole spare circuit breakers or spaces, or fraction thereof, but not less than two conduits. 3.02 WIRE INSTALLATION A.Branch circuit conductors shall be as follows: 1.For general applications through size #8: THWN 75oC wire and full size ground, or type THHN 90oC. 2.Branch circuit conductors through size #10 to be solid, #8 and larger stranded. 3.Unless indicated on the drawings, (the minimum) wire used for branch circuits shall be #12 THWN protected by 20 ampere circuit breakers. 4.Branch circuits for receptacles shall be on 20 amp, single pole circuit breakers with #12 conductors. No more than eight (8) duplex receptacles shall be on any one branch circuit. Circuits serving bathroom GFCI receptacles may serve lighting but shall not serve any other receptacles. 5.Lighting branch circuit shall not be loaded to more than 70% of breaker rating, in effect, 14 amps per circuit. B.The drawings indicate the general direction of routes of branch circuit home runs. Continue all such home runs to panels as though the routes were completely indicated. 1.Conductors shall be continuous from outlet box to outlet box, or junction box, with no splices except in such boxes. 2.Do not install wire in conduits until after plastering or drywall is completed and all moisture has been removed from conduits. 3.03 WIRING DEVICE INSTALLATION A.Review architectural and mechanical drawings before installing outlets. Changing of outlets to conform to these drawings and any other slight change in mounting height or location of outlets required shall be considered as a part of this contract. Use outlet boxes of sufficient size and shape to best suit the particular location and to contain the enclosed wire and connections without crowding. Size all boxes per N.E.C. Article 370. B.Switch and receptacle outlet boxes shall be standard boxes with cover plates. Where more than one switch or device is located at one point, use gang boxes and gang cover plates. C.Flush mount lighting switches 4'0" centerline above finished floor unless otherwise indicated. Flush mount wall type receptacles and other wall mounted wiring devices and outlets 18 inches centerline above finished floor unless otherwise indicated. D.Route dedicated neutral conductors on line and load side of dimmers per manufacturer's instructions. E.Set metal floor boxes level. Trim after installation to fit flush with finished floor surfaces. 3.04 DEVICES A.Support all junction boxes and other electrical devices in a manner as required by the N.E.C. Use extra bracing, supports, etc. as necessary to provide a proper and substantial base to which all electrical equipment is attached. 3.05 EQUIPMENT FURNISHED BY OTHERS AND/OR OWNER A.Verify exact location and requirements of equipment to be furnished by others prior to rough-in. B.Inspect owner furnished equipment for damage, defects, missing components, etc. Report deficiencies to the Owner immediately. Do not install or connect deficient equipment. C.Rough-in equipment furnished by Owner to locations as required. Final connections will be made by Electrical Contractor. 3.06 EQUIPMENT CONNECTIONS A.Final connections to motors, transformers and other vibrating equipment shall be with seal tite flex and approved fittings. Do not secure conduits, disconnects, or devices to ductwork or mechanical equipment. B.Final connections to equipment shall be in accordance with manufacturer's approved wiring diagrams, details, and instructions. It shall be the Contractor's responsibility to provide materials and equipment compatible with equipment actually supplied. END OF SECTION 26100 SECTION 26500--LIGHTING PART 1 - GENERAL 1.01 PROVISIONS A.Provide all interior and exterior lighting fixtures as shown on the plans and hereinafter specified. All items shall be provided to make a complete and operable lighting system, including lamps, ballasts, poles, hangers, painting, plaster frames, etc. B.Verify trim, finish and general description of all lighting fixtures through shop drawing approval prior to placing order for fixtures. Modify catalog numbers accordingly. PART 2 - PRODUCTS 2.01 INCANDESCENT FIXTURES A.Incandescent fixtures to be complete with lamps, and all necessary accessories to provide for their installation. Provide necessary blocking or other protection to maintain separation of recessed fixtures from combustible material and building insulation system. All recessed fixtures to have thermal protection device. Provide sloping ceiling adaptors where required to place lamp center line beam candlepower perpendicular to the working plane. 2.02 FLUORESCENT FIXTURES A.Fluorescent fixtures to be complete with lamps, and all necessary accessories to provide for their complete installation. Ballasts to be HPF, CBM/ETL, and U.L. listed, class P. Surface fluorescent fixtures to be mounted on low density combustible ceilings to have a U.L. listing for such mounting. All lenses to be acrylic prismatic plastic types or as shown in the schedule. B.Fluorescent ballasts shall be electronic programmed-start type, sound rating A, THD less than 10 percent, ballast factor of .88 or higher and power factor of 0.95 or higher. 2.03 HIGH INTENSITY DISCHARGE FIXTURES A.High intensity discharge fixtures to be complete with lamps and all necessary accessories to provide for their complete installation. Ballasts to be constant wattage auto-transformer types, except where noted. B.All HID ballasts shall be manufactured to ANSI standards and so labeled. HID ballasts shall be electronic type, sound rating A, THD less than15 percent, power factor of 0.90 or higher. 2.04 EMERGENCY OR NIGHT LIGHTING A.Fixtures indicated as being on emergency, or night light circuits shall be provided with self-contained battery powered inverter unit for direct mounting in fixture. Provide unit with fully automatic two rate charger, nickel cadmium battery, AC "on" pilot light, and test switch. Design and wire unit to automatically transfer to battery supply on loss of normal AC power and to operate 32 watt T8 fluorescent lamp with minimum output of 600 lumens for minimum 1-1/2 hours. 2.05 LAMPS A.Lamps shall be as shown in the fixture schedule as manufactured by Osram-Sylvania, G.E., Phillips, or approved equivalent. PART 3 - EXECUTION 3.01 INSTALLATION A.Install lighting fixtures straight and true with reference to adjacent walls, and securely fasten to and support by structural members of the building. Refer to architectural or interior reflected ceiling plans and elevations for exact location of fixtures. B.Provide photocontrols, time clocks, contactors, relays, etc. to control interior and exterior fixtures. All items for lighting controls that are to be mounted outdoors or in wet locations shall be installed in weatherproof housings. C.Recessed light fixtures installed in gyp. board or plaster ceilings shall have plaster frames installed prior to ceiling material. D.Multi-ballasted fluorescent fixtures shall be dual switched unless noted otherwise. E.Fixtures recessed in "t-bar" ceiling shall be supported independently of ceiling system, with four #12 hanger wires up to structure. Secure hanger wires to corners of fixture. Clip fixture to grid on two sides with factory-furnished clips. Final connection to fixture shall be made with a flexible U.L. approved assembly. END OF SECTION 26500 END OF DIVISION Designed: Reviewed: Project No:8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E0.1.DWG03.15.184:51:31 PMScale:As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: 100% Construction DocumentsALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820www˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL SPECIFICATIONS BAS MAS E0.1 08/21/18 SCALE: 1 ELECTRICAL FIRST FLOOR PLAN - DEMO 1/8"= 1'-0" 1. SALVAGE EXISTING ELECTRICAL AND FIRE ALARM DEVICES FOR REUSE. REFER TO ELECTRICAL PLAN ON SHEET E2.1 FOR NEW LOCATIONS. 2. SALVAGE EXISTING ELECTRICAL CIRCUITS FOR REUSE. REFER TO ELECTRICAL PLAN ON SHEET E2.1 FOR LOCATIONS OF WHERE REUSED CIRCUITS SHALL BE USED. 3. WHERE EXISTING ELECTRICAL CIRCUITS ARE NOT BEING REUSED, REMOVE CIRCUIT IN ITS ENTIRETY TO PANEL. NOTES: F F CO F TV TV TV H C C C H H H H H C C C C H (E) PANEL 'L12' CO H (E) PANEL 'L11' (E) DIMA-1 (E) DIMA-2 (E) DIMA-3 (E) DIMB-1 (E) DIMB-2 J FLAG NOTES: 1 SALVAGE THE EXISTING CIRCUIT SERVING THIS RECEPTACLE FOR REUSE. REFER TO ELECTRICAL PLAN ON SHEET E2.1 FOR NEW RECEPTACLE LOCATION. SALVAGE EXISTING FIRE ALARM DEVICE FOR RELOCATION. REFER TO ELECTRICAL PLAN ON SHEET E2.1 FOR NEW DEVICE LOCATION. 1 1 1 1 11 1 1 2 2 2 2 2 Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E2.0.DWG03.15.184:51:42 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: 100% Construction DocumentsALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL FIRST FLOOR PLAN - DEMO BAS MAS E2.0 08/21/18 SCALE: 1 ELECTRICAL FIRST FLOOR FLOOR PLAN - NEW 1/8"= 1'-0" 1. METER PANEL 'L11' IN ELECTRICAL ROOM 110 FOR 30 DAYS PER NEC 220.87 TO DETERMINE AVAILABLE LOAD CAPACITY. IT IS ASSUMED AT TIME OF PERMIT, PANEL 'L11' HAS SUFFICIENT CAPACITY FOR ADDED LOADS. ELECTRICAL CONTRACTOR TO PROVIDE ELECTRICAL ENGINEER WITH METERED DATA PRIOR TO INSTALLATION OF ELECTRICAL SYSTEMS TO VERIFY SUFFICIENT CAPACITY IN PANEL. 2. FIRE ALARM SCOPE LIMITED TO REMODEL SCOPE ONLY. FIRE ALARM SYSTEM SHALL COMPLY WITH NATIONAL, STATE, AND LOCAL CODES. SYSTEM SHALL BE DESIGN/BUILD BY CONTRACTOR. FIRE ALARM DEVICES SHOWN ON PLAN ARE FOR DESIGN INTENT. FINAL DESIGN RESPONSIBILITY BY DESIGN/BUILD CONTRACTOR. NOTES: FLAG NOTES: 1 REUSE EXISTING TV RECEPTACLE CIRCUIT FROM EAST WALL OF BAR TO SERVE NEW TV LOCATION. REUSE EXISTING TV RECEPTACLE CIRCUIT FROM WEST WALL OF PRIVATE LOUNGE TO SERVE NEW TV LOCATION. REUSE EXISTING ELECTRICAL CIRCUIT FROM WEST WALL RECEPTACLES BEING REMOVED TO SERVE NEW FLOOR RECEPTACLES. PROVIDE HUBBELL S1R8PTFIT2 8" FIRE RATED POKE-THROUGH WITH (2) DUPLEX RECEPTACLES. COORDINATE EXACT REQUIREMENTS WITH LOW-VOLTAGE CONTRACTOR PRIOR TO ROUGH-IN. COORDINATE EXACT LOCATION WITH ARCHITECT PRIOR TO ROUGH-IN. REFER TO ARCHITECTURAL DETAILS FOR FIRE PROOFING OF PENETRATION. REUSE EXISTING ELECTRICAL CIRCUIT FROM WEST WALL RECEPTACLES BEING REMOVED TO SERVE NEW TV RECEPTACLE. REUSE EXISTING RECEPTACLE CIRCUIT FROM PRIVATE LOUNGE TO SERVE NEW RECEPTACLE LOCATION. ROUTE 1" CONDUIT WITH PULL STRING FROM ELECTRICAL ROOM 110 TO THIS LOCATION FOR FUTURE USE. RELOCATE EXISTING FIRE ALARM DEVICE AT THE SOUTHEAST CORNER OF THE EXISTING FIREPLACE TO THIS LOCATION. RELOCATE THE EXISTING FIRE ALARM DEVICES AT THE SOUTHWEST CORNER OF THE EXISTING FIREPLACE TO THIS LOCATION. PROVIDE (2#12 & 1#12GRD) IN A 3/4"C FROM PANEL 'L11' LOCATED IN ELECTRICAL ROOM 110 TO THIS LOCATION. COORDINATE EXACT POWER REQUIREMENTS OF FIREPLACE WITH FIREPLACE SUBMITTAL PRIOR TO ROUGH-IN. TV F F H H H H (E)C (E)C H (E) PANEL 'L12' H J FP (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) CO (E) PANEL 'L11' (E) DIMA-1 (E) DIMA-2 (E) DIMA-3 (E) DIMB-1 (E) DIMB-2 TV S TV J J (E)FP FP FP J S STV 1 TV 2 2 TV 3 3 3 4 4 5 5 H L11-2,4 L11-6 L11-28 L11-26 J J J J 6 6 6 6 6 F CO 7 8 7 8 H 9 9 9 L11-30 L11-32 L11-34 10 10 Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E2.1.DWG03.15.184:51:51 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: 100% Construction DocumentsALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL FIRST FLOOR PLAN - NEW BAS MAS E2.1 08/21/18 SCALE:1 LIGHTING FIRST FLOOR RCP PLAN - DEMO 1/8" = 1'-0" CK CK CK SSCK 1. SALVAGE EXISTING FIXTURES FOR RELOCATION. RE: RCP ON SHEET E3.1 FOR NEW LOCATION. FLAG NOTES:# 1 1. AREAS NOTED WITH HATCHING ARE FIXTURES TO BE DEMO'D. SALVAGE EXISTING ELECTRICAL CIRCUITS FOR REUSE. NOTES: Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E3.0.DWG03.15.184:52:03 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: 100% Construction DocumentsALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL FIRST FLOOR RCP - DEMO BAS MAS E3.0 08/21/18 SCALE:1 LIGHTING FIRST FLOOR RCP PLAN - NEW 1/8" = 1'-0" 1. NEW LIGHT FIXTURES ARE OWNER-PROVIDED, CONTRACTOR INSTALLED. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR FIXTURE SPECIFICATIONS. 2. NEW LIGHTING IS EQUAL TO OR LOWER WATTAGE OF EXISTING LIGHT FIXTURES. ELECTRICAL CONTRACTOR SHALL DISCONNECT EXISTING LIGHT FIXTURES AND CONNECT NEW LIGHT TO EXISTING CIRCUIT. NOTES: 1. FIXTURE SHALL BE REPLACED WITH OWNER PROVIDED, CONTRACTOR INSTALLED FIXTURE. 2. RELOCATED LIGHTING FIXTURE. 3. PROVIDE LUTRON MS-B102 DUAL TECHNOLOGY, LINE-VOLTAGE OCCUPANCY SENSOR SWITCH OR EQUIVALENT. FLAG NOTES:# CK CK CK SSCK (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E)(E) (E) (E)(E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) SO 12 2 2 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E3.1.DWG03.15.184:54:58 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: 100% Construction DocumentsALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL FIRST FLOOR RCP - NEW BAS MAS E3.1 08/21/18 1. AREAS NOTED WITH HATCHING ARE FIXTURES TO BE DEMO'D. SALVAGE EXISTING ELECTRICAL CIRCUITS FOR REUSE. NOTES: SCALE:1 LIGHTING PORTE COCHERE RCP - DEMO 1/4" = 1'-0"Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E3.2.DWG03.15.184:52:22 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: 100% Construction DocumentsALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL PORTE COCHERE RCP - EXISTING BAS MAS E3.2 08/21/18 1. NEW LIGHT FIXTURES ARE OWNER-PROVIDED, CONTRACTOR INSTALLED. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR FIXTURE SPECIFICATIONS. 2. NEW LIGHTING IS EQUAL TO OR LOWER WATTAGE OF EXISTING LIGHT FIXTURES. ELECTRICAL CONTRACTOR SHALL DISCONNECT EXISTING LIGHT FIXTURES AND CONNECT NEW LIGHT TO EXISTING CIRCUIT. NOTES: SCALE:1 LIGHTING PORTE COCHERE RCP - NEW 1/4" = 1'-0" (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) (E) (E) (E)(E) (E)(E) (E) (E) (E)(E) (E) (E) (E) (E) (E) (E) (E) 1 111 1 1 1. FIXTURE SHALL BE REPLACED WITH OWNER PROVIDED, CONTRACTOR INSTALLED FIXTURE. FLAG NOTES:# Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E3.3.DWG03.15.184:52:32 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: 100% Construction DocumentsALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL PORTE COCHERE RCP - NEW BAS MAS E3.3 08/21/18 NO SCALE TYPICAL DEVICE ALIGNMENT EQ EQ 6"MIN. ℄ ℄ ℄ DOOR WINDOW EQ EQ ℄LIGHTING CONTROL ℄ ℄ OFFSET COMMUNICATIONS DEVICES FROM POWER DEVICES TO EITHER OPPOSITE SIDE OF STUD BAY, OR ADJACENT STUD BAY. NOTES: 1. IF ALIGNMENT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. EQ BACKSPLASH ABOVE COUNTER DEVICE RECEPTACLE COUNTERTOP EQ FINISHED FLOOR FINISHED CEILING 6" MIN. 20" MAX. ALIGN DEVICES (OUTLETS, CONTROLS, ETC.) VERTICALLY. DO NOT VERTICALLY ALIGN POWER AND COMMUNICATIONS DEVICES SIMULTANEOUSLY. 18" 48"64" 78" 90" 78" 64" 90" 6"MIN FIRE ALARM DEVICES 48" ELECTRICAL DEVICES 96" NOTES: 1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. WALL-MOUNT NO SCALE TYPICAL DEVICE MOUNTING HEIGHTS OC DLV S CBC TSTC ANN FACP SH SH F 120" MAX. 80" MIN. 96" MAX. TOP OF DEVICE 9'-0"+ CEILING 8'-0" CEILING TOP OF CABINET TOP OF CABINET TOP OF DEVICE CL OF DEVICE TOP OF DEVICE TOP OF CABINET TOP OF CABINET BOTTOM OF DEVICE MINIMUM, TOP OF DEVICE FINISHED FLOOR FINISHED CEILING Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15E4.0.DWG03.15.184:52:38 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: 100% Construction DocumentsALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates ELECTRICAL DIAGRAMS BAS MAS E4.0 08/21/18 ' ' ISSUE LOG KEY: # DATEISSUE LOG MECHANICAL SHEET INDEX TITLE MECHANICAL COVER PAGEM0.0 DESIGN DEVLOPMENT08/21/2017ISSUED AS PART OF A SET ' ' NOT PART OF SET ' ' ISSUED FOR INFORMATION ONLY* √ √ √ √ √ √ MECHANICAL GARAGE PLAN -DEMOM2.0 MECHANICAL GARAGE PLAN - NEWM2.1 MECHANICAL FIRST FLOOR - DEMOM3.0 MECHANICAL FIRST FLOOR PLAN - NEWM3.1 SINGLE LINE DESCRIPTION DOUBLE LINE D D SPLIT BRANCH TAKE-OFF WITH SQUARE ELBOW & SPLITTER DAMPER SPLIT BRANCH TAKE-OFF WITH RADIUS ELBOW & SPLITTER DAMPER POSITIVE PRESSURE RISER, TYPICALLY SUPPLY NEGATIVE PRESSURE RISER, TYPICALLY RETURN, EXHAUST OR OUTSIDE AIR F/S COMBINATION FIRE & SMOKE DAMPER F/S FIRE DAMPER MOTOR OPERATED DAMPER (MOD) MANUAL VOLUME DAMPER, SINGLE BLADE DAMPER (SBD) FOR ROUND OR <10" TALL, OPPOSED BLADE DAMPER (OBD) >10" TALL BACKDRAFT DAMPER BDD BDD SMOKE DAMPER SMOKE DETECTOR DUCT SIZE: FIRST NUMBER IS PLAN WIDTH, SECOND NUMBER IS DEPTH. 24x36 24x36 DUCTWORK LEGEND SDSD PRESSURE REDUCING VALVE SHOCK ABSORBER STRAINER W/ BLOW-OFF VALVE SAFETY RELIEF VALVE VACUUM BREAKER PRESSURE GAUGE W/ PIG TAIL & COCK THERMOMETER PRESSURE - TEMP. TAP AIR VENT PIPE ANCHOR FLEXIBLE CONNECTOR PIPE EXPANSION JOINT PIPE UNION DOUBLE CHECK BACKFLOW PREVENTER PUMP & EQUIPMENT CONNECTOR TEMPERATURE CONTROL VALVE (2-WAY) DRAIN VALVE W/ HOSE END PLUG VALVE IN RISER FLOW BALANCING VALVE GATE OR GLOBE VALVE IN RISER FLOW CONTROL VALVE BALL VALVE PLUG OR BALANCING VALVE CHECK VALVE GLOBE VALVE BUTTERFLY VALVE VENTURI/FLOW INDICATOR TEMPERATURE CONTROL VALVE (3-WAY) SOLENOID VALVE 90° ELBOW UP TEE UP TEE DOWN SHUT OFF (BALL, GATE, BUTTERFLY) PIPING SYMBOLS 90° ELBOW DN S DUCT/PIPE RISER DESIGNATION KEY CH DW HW G W V PR ST S2 FLOW SWITCH HOSE BIBB WALL HYDRANT TEMPERATURE CONTROLLER OR SENSOR STEAM TRAP TEST CHAMBER STEAM TRAP: FT-FLOAT & THERMOSTATIC TD-THERMODYNAMIC IB-INVERTED BUCKET TS-THERMOSTATIC BP-BALANCED PRESSURE BAR SINK BS 1/2" 1/2" 1-1/2"1-1/2" FIXTURE CONNECTION SCHEDULE HW CW WASTE VENT NOTES: 1. SIZES SHOWN ARE MINIMUM PIPE SIZES TO A SINGLE FIXTURE. LARGER SIZES MAY BE INDICATED ON PLANS WHERE REQUIRED. 2. MINIMUM DOMESTIC PIPE SIZE TO (2) OR MORE FIXTURES IS 3/4". 3. RE: MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR INDIRECT WASTE SIZES. 4. WASTE AND VENT SIZES SHOWN ABOVE APPLY TO INDIVIDUAL VENTING ONLY. WHERE ALLOWED, INDIVIDUAL VENT CONNECTIONS MAY BE OMITTED OR SIZES MAY VARY WHEN CIRCUIT VENTS, COMMON VENTS, WASTE STACK VENTS, WET VENTS, OR COMBINATION DRAIN AND VENT SYSTEMS ARE USED. PRIOR APPROVAL FROM THE ENGINEER IS REQUIRED TO USE THESE ALTERNATIVE VENTING METHODS. 5. PROVIDE TRAP PRIMER FOR ALL FLOOR DRAINS AND FLOOR SINKS NOT LOCATED IN FOOD SERVICE AREAS. 6. MINIMUM SIZE FOR WASTE AND VENT PIPING BENEATH SLAB IS 2". 7. ALL FIXTURES LISTED ARE NOT NECESSARILY USED ON THIS PROJECT. 8. REFER TO APPLIANCE SCHEDULES (BY OTHERS) FOR ADDITIONAL PLUMBING FIXTURE CONNECTIONS SUCH AS INST-HOTS, COFFEE MAKERS, AND GARBAGE DISPOSALS. 9. PROVIDE ICE MAKER BOX ROUGH IN W/ 1/2"CW CONNECTION FOR ALL REFRIGERATOR LOCATIONS. ABBREV. CS CLOTHES WASHER ROUGH-IN 1/2" 1/2" 2" 1-1/2" DRINKING FOUNTAIN / E.W.C. DF - 1/2" 1-1/2" 1-1/2" DISH MACHINE ROUGH-IN DM 3/4" 3/4" 2" 1-1/2" DW DISHWASHER ROUGH-IN - 1/2" 2" 1-1/2" FD FLOOR DRAIN - - 2" 1-1/2" FS FLOOR SINK - - 3" 2" HOSE BIB HB - - -3/4" HAND SINK HS 1-1/2" 1-1/2"1/2" 1/2" KITCHEN SINK W/ OR W/O DISPOSER KS 1/2" 1/2" 2" 1-1/2" LAVATORY LAV 1/2" 1-1/2" 1-1/2"1/2" MOP SERVICE BASIN MSB 3/4" 3" 2"3/4" SHOWER / BATHTUB SH 3/4" 3/4" 2" 1-1/2" SERVICE SINK SS 3" 2"1/2" 1/2" TROUGH DRAIN TD - - 3" 2" URINAL (BLOWOUT) UR 1" 2" 1-1/2"- URINAL (WASHDOWN) UR UR URINAL (WATERLESS) 3/4" 2" 1-1/2" - 2" 1-1/2" - - WATER CLOSET (FLUSH VALVE) WC WATER CLOSET (FLUSH TANK) WCT - 1" 4" 2" - 1/2" 4" 2" WS 3/4" 3/4" 2" 1-1/2"WORK SINK EQUIPMENT ABBREVIATIONS AIR HANDLING UNITAHU AIR SEPARATORAS BOILER (HOT WATER)B BASE BOARDBB BUFFER TANKBT CONSTANT VOLUME BOXCV DISHWASHER EXHAUST FANDEF ELECTRIC BASEBOARD HEATEREBH FURNACEF FAN COILFC FAN POWERED BOXFP GLYCOL FEEDERGF HUMIDIFIER HC HEATING COIL HP HEAT PUMP HX HEAT EXCHANGER KITCHEN EXHAUST FANKEF MAKE-UP AIR UNITMAU MOTOR CONTROL CENTERMCC MIXING VALVEMV PUMPP RETURN (OR RELIEF) AIR FANRF RADIANT ZONERZ SNOWMELT AREASA SUMP BASINSB SUPPLY FANSF STORAGE TANKST THERMOSTATIC MIXING VALVETMV UNIT HEATERUH VARIABLE VOLUME BOXVV WATER HEATERWH H CHILLERCH COOLING COILCC CIRC PUMPCP CABINET UNIT HEATERCUH COOLING TOWERCT DUCT COILDC ELECTRIC WATER HEATEREWH EVAPORATIVE COOLING UNITECU ENERGY RECOVERY UNITERU EXHAUST FANEF EXPANSION TANKET VARIABLE VOLUME BOX W/ REHEATVR TYPE OF AIR DEVICE RE: GRD SCHEDULE. AIR DEVICE DESIGNATION KEY # CA EXH OSA RA XFR SIZE (INCHES) OR MINIMUM FREE AREA REQUIRED IN SQUARE FEET. NOTE: FOR STANDARD MODULE SIZE REGISTERS, SIZE GIVEN IS NECK SIZE. REFER TO GRD SCHEDULE FOR MODULE SIZE. INDICATES AIR INLET DEVICE. = = = = = = AIR QUANTITY (CFM) COMBUSTION AIR EXHAUST OUTSIDE AIR RETURN TRANSFER B XFR 12x6 A 150 12x6 REFERENCE SAMPLE FFI = FOR FURTHER INFORMATION FCT = FOR CONTINUATION RE: B/M400 FFI REFER TO: DRAWING NUMBER OR DIAGRAM LETTER SHEET NUMBER PLAN ABBREVIATIONS ABOVE FINISHED FLOOR AIR ADMITTANCE VALVE ABOVE FINISHED GRADE AUTOMATIC BUILDING CONTROL SYSTEM BACK DRAFT DAMPER BUILDING AAV AFF AFG AUTO BCS BDD BLDG BETWEEN COMMON (OR CLOSED) COMBUSTION AIR CONTROLS CONTRACTOR CONTINUATION DESIGN BUILD B/N C CA CC CDBBC CUBIC FEET PER MINUTE (AIR FLOW RATE) CAST IN PLACE CEILING (OR COOLING) CONCRETE CONDENSATE CONNECT (OR CONNECTION) CONTRACTOR CFM CIP CLG CONC COND CONN CONTR'R CLEANOUT TO GRADECOTG DOMESTIC HOT WATER RECIRC EXISTING DWR (E) EXHAUST AIREA ENTERING AIR TEMPERATURE ELECTRICAL CONTRACTOR ENTERING WATER TEMPERATURE EAT EC EXH EXHAUST EWT GENERAL CONTRACTOR GROUND HEAT EXCHANGER GC GHX GALLONS PER MINUTE (WATER FLOW RATE)GPM HORSEPOWER HOT WATER IN LIEU OF HP HW ILO KILOWATTSKW LEAVING AIR TEMPERATURE LINEAR FOOT LEAVING WATER TEMPERATURE LAT LF LWT MECHANICAL CONTRACTORMC MANUFACTURER MOTOR OPERATED DAMPER NEW MFG MOD (N) NORMALLY CLOSEDNC NATIONAL ELECTRIC CODE NOT IN CONTRACT NORMALLY OPEN NEC NIC NO OUTSIDE AIROA OPPOSED BLADE VOLUME DAMPER ON CENTER OBD OC OUTSIDE AIROSA RETURN AIR REQUIRED RA REQ'D REQUIREMENTSREQ'MTS SUPPLY AIR SQUARE FOOT (FEET) SA SF STATIC PRESSURESP STAINLESS STEEL THROW-AWAY (TRANSFER AIR) TYPICAL SS TA TYP UNLESS NOTED OTHERWISEUNO WALL CLEANOUTWCO WITH REGARD TO WATER COOLED TRANSFER WRT W/C XFR DIAMETERØ BY CONTRACTOR COLD WATERCW HOT WATER RECIRCHWC ABOVEABV BELOW FINISHED GRADEBFG DOMESTIC WATER DOMESTIC HOT WATER DW DHW DOWNDN DOMESTIC HOT WATER RECIRCDHR COMBINATION FIRE/SMOKE DAMPER FURNISHED BY OWNER FSD FBO FLOOR CLEANOUTFCO FOR CONTINUATIONFCT FD FIRE DAMPER REFER TO:RE: WITHW/ CLEANOUTCO FUTURE(F) FREE AREAFA FFI FOR FURTHER INFORMATION WITHOUTW/O VENT THRU ROOFVTR NOTES 1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONS ON LEGEND SHEET ARE NOT NECESSARILY USED ON THIS PROJECT. 2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES AND NOTATION CONVENTIONS OCCURRING IN THIS DRAWING SET ARE NECESSARILY DEFINED ON THESE LEGENDS. CONSULT THE ENGINEER IN THE EVENT SYMBOLOGY OR NOTATION INTERPRETATION IS REQUIRED. EA OA RA SA RISER NUMBER - - - - - - - - - - - - CHILLED WATER DOMESTIC WATER HEATING WATER GAS WASTE AND/OR VENT PIPING RISER (MISC TYPES) STORM DRAIN SECONDARY STORM DRAIN EXHAUST AIR OUTSIDE AIR RETURN AIR SUPPLY AIR AIR SIDE: PIPING SIDE: PLAN SYMBOLS CONTROL PANEL/RADIANT MANIFOLD CARBON DIOXIDE SENSOR CARBON MONOXIDE SENSOR DIAGRAM CONTINUATION REFERENCE PLUMBING/HVAC RISER POINT OF NEW CONNECTION DUCT STATIC PRESSURE SENSOR ROOM PRESSURE SENSOR EMERGENCY POWER OFF SWITCH ACCESS PANEL SNOWMELT MANIFOLD SECTION CUT LETTER/SHEET SHOWN ON POINT OF DISCONNECTION - SP CO2 EPO P CO -- - P THERMOSTAT HUMIDISTAT REMOTE TEMPERATURE SENSOR T S H H B W H TC FS ROOF DRAIN FLOOR DRAIN FLOOR SINK HORIZONTAL CLEANOUT VERTICAL CLEANOUT DECK/ROOF DRAIN ABOVE PIPING DESIGNATIONS SNOWMELT SUPPLY SNOWMELT RETURN NATURAL GAS MEDIUM PRESSURE GAS DOMESTIC WATER DOMESTIC HOT WATER DOMESTIC HOT WATER (TEMP. SHOWN) DHW RECIRCULATION FIRE LINE PLUMBING VENT PIPE WASTE PIPE STORM DRAIN PIPE STORM DRAIN OVERFLOW COMPRESSED AIR PIPE GREASE WASTE PIPE HEATING WATER SUPPLY HEATING WATER RETURN DRAIN PIPE GREASE VENT PLUMBING PIPING NON-SOFTENED DOMESTIC WATER HWR HWS SMS SMR D MG G CW HW HWC NS 140° HW GV ST GW V W ST(OF) F CA HYDRONIC PIPING 90° ELBOW DOWN (ROUND DUCT ONLY) ROUND 90° ELBOW UP (ROUND DUCT ONLY) OFFSET TO CHANGE ELEVATION (AT 30° WHEN POSSIBLE) D = DROP R = RISE ROUND RADIUS ELBOW 90° STRAIGHT TEE 90° CONICAL TEE 45° BRANCH 45° CONICAL TEE SIZE OR SHAPE TRANSITION ROUND FLEXIBLE DUCT 90° ELBOW DN (NEGATIVE PRESSURE) 90° ELBOW DN (POSITIVE PRESSURE) 90° ELBOW UP (NEGATIVE PRESSURE) 90° ELBOW UP (POSITIVE PRESSURE) 90° RADIUS ELBOW 90° RADIUS ELBOW W/TURNING VANES SQUARE DUCT SPLIT ROUND DUCT SPLIT SUMP PUMPSP PR 203 MECHANICAL SYSTEMS LEGEND ABOVE SEA LEVEL PROJECT ALTITUDE 8,150 MECHANICAL DIAGRAMS M4.0 √ 25% CD09/25/2017√ √ √ √ √ √ BUILDING PERMIT03/15/2018√ √ √ √ √ √ Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15M0.0.DWG03.15.186:42:34 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates MECHANICAL COVER SHEET DAL DAL M0.0 08/21/18 SCALE: 1 MECHANICAL GARAGE FLOOR PLAN - DEMO 1/8" = 1'-0" DEMO NOTES: 2" EXISTING GAS UP TO FIREPLACE TO REMAIN. 1 1/2" GAS 2" GAS 1 1/2" EXISTING GAS UP TO PANTRY KITCHEN TO REMAIN. 1 2 1" EXISTING GAS UP TO FIRE PIT TO REMAIN. 1 2 3 3 G(E)G(E) CW(E) CW(E)FIELD VERIFY EXACT LOCATIONS OF EXISTING HOT, COLD, & RECIRC WATER LINES FOR NEW CONNECTIONS. 4 HW(E) HW(E)HWC(E)HWC(E) 4 4 EXISTING GAS MAIN FOR NEW CONNECTIONS. FIELD VERIFY EXACT LOCATION. 5 5 G(E)5 G(E) 5 G(E)5 Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15M2.0.DWG03.15.186:42:41 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates MECHANICAL GARAGE PLAN -DEMO DAL DAL M2.0 08/21/18 SCALE: 1 MECHANICAL GARAGE FLOOR PLAN - NEW 1/8" = 1'-0" FLAG NOTES: 1 EXISTING GAS TO FIRE PIT.1 3/4" CW 3/4" HW 1/2" CW1/2" HW1/2" CW1/2" HW1 1/2" GAS 2" GAS G(E)G(E) CW(E) CW(E)HW(E) HW(E)HWC(E)HWC(E) G(E)G(E) G(E)1/2" HWC DOMESTIC WATER SUPPLY/RETURN PIPING ROUTED TO EXISTING LINES. COORDINATE CONNECTION LOCATIONS IN FIELD. 2 2 2 3 REFER TO DETAIL C/M4.0 FOR EXTERIOR SINK WINTERIZATION VALVING. 3 3 1” G 1” G 1-1/4” G 1-1/4” G 1” G 1” G1” G 1” G NEW GAS LINE UP TO FIRE PIT.4 NEW GAS LINE UP TO BBQ.5 4 4 4 4 5 5 Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15M2.1.DWG03.15.186:42:47 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates MECHANICAL GARAGE PLAN DAL DAL M2.1 08/21/18 SCALE: 1 MECHANICAL FIRST FLOOR DEMO FLOOR PLAN - DEMO 1/8" = 1'-0" DEMOLITION NOTES: 1 DEMO EXISTING CABINET HEATERS, PIPING, AND CONTROLS. CAP AND VALVE HWS/R ABOVE CEILING IN ACCESSIBLE LOCATIONS. 2 DEMO EXISTING FIREPLACE AND VENT PIPING. RECONFIGURE FOR NEW FIREPLACE. SEE CONSTRUCTION PLANS. 3 RE-POSITION EXISTING SA DUCT/ REGISTER TO ACCOMMODATE NEW ARCH. 1 2 3 3 1 3 3 T T T T CO CO 5 5 65 4 5 6 RE- WORK PLUMBING IN THIS AREA TO ACCOMMODATE ARCH AND EQUIPMENT CHANGES. REMOVE AND RELOCATE THERMOSTAT. REMOVE AND RELOCATE CO SENSER. 4 5 6 Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15M3.0.DWG03.15.186:43:02 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates MECHANICAL FIRST FLOOR DEMO PLAN DAL DAL M3.0 08/21/18 SCALE: 1 MECHANICAL FIRST FLOOR PLAN - NEW 1/8" = 1'-0" 1. HVAC OR PLUMBING SYSTEM IN ALL OTHER AREAS TO REMAIN "AS IS". NOTES: FLAG NOTES: 1 RE-POSITION EXISTING, CUSTOM SA DIFF TO ACCOMMODATE ARCH CHANGES. RE-BALANCE AIR FLOW AND RE-COMMISION SYSTEM & CONTROLS MODIFY EXISTING DUCT WORK AS NEEDED. RE-COMMISION EXISTING HVAC SYSTEM AND RE-BALANCE AIR FLOW. SEE NOTE #13. RELOCATE THERMOSTAT. RELOCATE CO SENSOR. EXTEND AND REWORK EXISTING PLUMBING SYSTEM TO ACCOMMODATE RELOCATED/ NEW KITCHEN/BAR EQUIPMENT. EXISTING FIRE PIT. UNIT TO REMAIN AS INSTALLED. PROVIDE VENTILATION SYSTEM FOR NEW MEDIA WALL. RE: DIAGRAM B ON SHEET M4.0. INSTALL NEW FIREPLACE FLUE TO MEET FIREPLACE MANUFACTURER'S REQUIREMENTS. EXISTING CONTROLS TO BE RE-INSTALLED. SEE PIPING FOR FIRE PITS, BBQS, AND SINKS ON LEVEL BELOW. NEW FIREPLACE BOTTOM INTAKE TO PULL AIR FROM UNIT BASE. INSTALL INTAKE PER MANUFACTURER'S REQUIREMENTS. RE: ARCH. PROVIDE FIREPLACE RELAY FOR HVAC MAKE UP AIR CONTROL. EXISTING LOUNGE AIR HANDLER SYSTEM TO BE SETUP FOR FIREPLACE MAKE UP AIR. ADJUST CONTROLS TO RESPOND TO FIREPLACE ACTIVATION AND BALANCE SYSTEM PER FIREPLACE MAKE UP AIR REQUIREMENTS. GAS PIPING CONNECTIONS PER DETAIL C ON SHEET M4.0. 11 1 1 2 2 T T T T T T CO2 CO2 5 9 3 3 3 4 9 7 8 6 2 3 4 5 6 7 8 9 a. CONTRACTOR TO RE- COMMISSION THE EXISTING SMOKE EVACUATION SYSTEM IN ACCORDANCE WITH RITZ AND CODE REQUIREMENTS. SMOKE EVACUATION SYSTEM TESTING 14 14 14 14 FP-1 FP-1 FP-1 FP-1 BBQ-1 BBQ-1 FP-2 T -500 12” -500 12”-50012”-50012”FAN-1 FAN-1 SK-1 SK-1 10 10 10 12"Ø12"Ø11 11 12 12 13 13 14 14 10 10 10 10 14 Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15M3.1.DWG03.15.186:43:09 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www ˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates MECHANICAL FIRST FLOOR PLAN DAL DAL M3.1 08/21/18 EXHAUST FAN SCHEDULE MARK TYPE FAN MOTOR MANUFACTURER* & MODEL #ACCESSORIES REMARKSCFM SONES ESP HP/ (WATT) VOLT/ PHASE@ S.L. (IN WC) @ ALT (IN WC) FAN-1 IN LINE 500 0.6 0.2 0.1 138 W 120V/1 GREENHECK CSP-A780 VARIABLE SPEED CONTROL & COOLING THERMOSTAT. - - - - - - - - - - - - MANUFACTURERS: * ACME, COOK, GREENHECK, PANASONIC, PENN GENERAL NOTES: A: B: GRILLE, REGISTER, DIFFUSER & LOUVER SYMBOL USE PATTERN FINISH MANUFACTURER* & MODEL #ACCESSORIES REMARKS COOLING LINEAR BAR WOOD CUSTOM DETAIL. CONTRACTOR/ARCH TO COORDINATE. - GRILLES REQUIRED TO HAVE 63% FREE AREA OR GREATER. (2.86 SQ. FT. FREE AREA MIN.) - - - - - - MANUFACTURERS: GRD KRUEGER, METALAIRE, TITUS LOUVER GREENHECK, L&D, RUSKIN GENERAL NOTES: A: B: A -- NO SCALE GAS TO VALVE BOX FIRE PIT OR BBQ EXISTING GAS MAIN IN PARKING GARAGE A VIDEO WALL VENTILATION DIAGRAM NO SCALE FLOOR CEILING CAVITY BEHIND WALL EXTERIOR WALL 10X10 EXH OPENING EXH FAN IN CELING, EF-1 10X10 DISCHARGE TO PLENUM, LINED. SEE FLOOR PLANS. FLOOR CEILING B TRANSFER AIR FROM ROOM, TYP. GRILLES ASSUMED TO BE 36x6, SIZING TO BE ADJUSTED PER FREE AREA REQUIREMENTS. SEE SCHEDULE BELOW. VIDEO WALL EXHAUST FAN/DUCTS INSTALLED IN DROPPED CEILING, TYP.1 General Workmanship 1. All subcontractors shall be licensed, experienced, and thoroughly knowledgeable in their respective areas of the construction industry and shall perform in a responsible manner with established construction sequence, shall recognize the priority of the construction documents, and shall inform the prime contractor of potential problems when the construction documents are unclear or inconsistent. 2. Work shall be performed in a workmanlike manner to the satisfaction of the architect, Owner, and Engineer. 3. It is the contractor's responsibility to perform their work in conformance with all applicable codes, ordinances and life safety features as required by local, state, or national authorities. The contractor shall coordinate with the architect if modification of his/her work is required for compliance. If a conflict between those publications exists, the most stringent requirement shall apply. 4. All materials and/or equipment shall be handled and installed as per manufacturer's specifications and recommendations. 5. Submit record documents to architect. Documents shall include all addendum items, change orders, alterations, rerouting, etc. 6. Systems shall be complete, operable, and ready for continuous operation prior to acceptance by the Owner. 7. Systems shall be tested for proper operation. Perform at a minimum all code required tests or systems. If tests of work are defective, contractor shall make corrections necessary at no additional cost to Owner. 8. Warranty the installation against defects in materials and workmanship. The warranty shall be for a period of one year after Owner's acceptance. Defects shall be promptly remedied without cost to the Owner. 9. Do not scale drawings. Verify dimensions in field prior to commencement of work. Refer to architectural drawings for all dimensions. 10. Pay for and secure all required permits and inspections. Prior to final payment, turn over all certificates of completion to architect. Bid/Submittals 1. Subcontractors shall be responsible to notify the prime contractor of discrepancies or conflicts in the construction documents found during bidding and/or prior to performing the work. 2. Provide a base bid which shall include only specified equipment or approved equivalents. No other substitutions for the listed equipment shall be allowed in the base bid. A. The manufacturer of equipment or materials first named on the drawings is the basis of design. Other manufacturers listed are considered general equivalents only. B. Coordination of general equivalents and substitutions: Where contract documents permit selection from several general equivalents, or where substitutions are authorized, coordinate clearance and other interface requirements with mechanical and other work. 1) Provide necessary additional items so that selected or substituted item operates equivalent to the basis of design and properly fits in the available space allocated for the basis of design. 2) Provide all features which are standard on the basis of design plus any specified options. 3) Be responsible for assuring that piping, conduit, duct, flue, and other service locations for general equivalents or substitutions do not cause access, service, or operational difficulties any greater that would be encountered with the base design. 3. Submit all mechanical division shop drawing and product data at one time. Partial submittals will be rejected. 4. Shop drawing submittals shall state capacities, sizes, etc., of all equipment and shall be certified and include computer based project specific selections where applicable. Clearly mark each shop drawing, catalog cut and/or specification sheet to indicate those products and features which are intended to be furnished. Specifically indicate any deviations from the design intent. Engineer reserves the right to require correction at no cost to Owner for deviations not specifically indicated in the submittals. Review and approval of shop drawings shall not relieve the Contractor from the responsibility of furnishing equipment and materials of proper dimension, size, quantity, quality and all performance characteristics to efficiently perform the requirements and intent of the contract documents. Submittal shall be bound and indexed in a neat and orderly manner. 5. Submittals shall include, but not be limited to: equipment, fixtures, insulation, diffusers, pumps, fans, piping, valves, boilers, furnaces, controls, and fire protection. 6. Failure to order, or release order for materials and/or equipment will not be accepted as a reason to substitute alternate materials, equipment, or installation methods, unless approved by the engineer. 7. Submit a balance report by a NEBB or AABC certified balancing contractor. Balancing procedures shall be in accordance with NEBB or AABC guidelines for proportional balance. Submit report on standard NEBB or AABC forms or submit forms for review prior to balancing. Measurements shall include all motor amperage and voltage readings; fan RPMs; static pressure at inlet and outlet of all equipment, at all controlled speeds. A. Adjust flows to within 10% of required quantity. If actual quantity is less than 90%, investigate cause, attempt to rectify and notify Engineer. B. Submit digital copies of all reports in addition to any required by the contractor and his suppliers. These files shall be retained by the owner, architect, and engineer. Discipline Coordination 1. Coordinate architectural, structural, mechanical, fire protection, electrical, landscaping, and interior design drawings prior to installation. 2. Verify electrical service voltage and phase available. 3. Subcontractor shall verify existence and location of all utility services and coordinate as required by their respective area of the construction, notifying the prime contractor of variations or conflicts. 4. Verify exact locations of existing underground utilities, piping, and raceway systems prior to trenching. Contractor shall obtain and verify exact utility company drawings and requirements. 5. Offset piping, ductwork, etc. As necessary to accommodate structure, beams, columns, equipment, etc. 6. Provide necessary trenching, excavation, supports, saw cutting, backfill, patching, and concrete/paving, etc., as required. Backfill trenches in 6” layers and to 90% compaction and patch to match final grade. 7. Temporary heat shall be furnished as required by the general contractor. Use of the permanent heating system will not be allowed. 8. Coordinate all penetrations of the floor slab prior to commencing work. Coordinate all new penetrations with other divisions of the work. All contractors are individually responsible for all penetrations required by their divisions. 9. See architectural reflected ceiling plan for all ceiling penetrations and air device locations. Mechanical 1. Mount all stats at 48” AFF where shown on floor plans unless noted otherwise. Coordinate locations with casework, furniture, door swings, heat sources, and exterior walls. Notify Engineer of any conflicts prior to beginning thermostat installation. 2. Ductwork: A. Flexible ductwork shall be UL listed and labeled, class 1 air duct. Working pressure rating: positive 6”, negative 4”. Flexmaster Type 5 or equivalent. Submit samples to determine equivalence. B. Flexible connection: Equivalent to Ventfab, fireproof glass cloth, 10” w.c. Rated. C. Round duct: Spiral seam, galvanized steel. Die stamped or 5 gore elbows. “Snap-Lock”, longitudinal seam duct, or adjustable fittings are acceptable on individual grille/diffuser runouts only. 1) Material shall meet all requirements of NFPA-90. 2) Install with adhesive and welded pins in accordance with SMACNA “HVAC Duct Construction Standards”. 3) Externally wrap all round supply air ducts with flexible glass fiber, ANSI/ASTM C612; 0.002 inch foil scrim facing. D. Ductwork: G60 galvanized sheet steel; lock forming quality; constructed to the latest edition of SMACNA “HVAC Duct Construction Standards”; +/- 1” WC pressure classification, seal class “C”; with galvanized steel fasteners, anchors, angles, straps, etc. E. Seal all seams (longitudinal and transverse) airtight with united McGill “Uni-Grip” UL listed, water based, non-hardening, elastic sealant or equivalent. Tape not allowed. 3. Provide ¼” galvanized mesh screen on all combustion air ducts or openings, and all open end return and exhaust ducts. 4. All ductwork dimensions are outside sheet metal dimensions. Duct liner has been accounted for. 5. Ductwork notes: A. Unless otherwise noted, all changes in direction shall be made with radius elbows with radius to centerline equal to 1.5 duct width. B. All flexible ducts shall not exceed eight feet in length. C. Ductwork support materials: Except as otherwise indicated, provide galvanized steel fasteners, anchors, rods, straps, trim and angles for support of ductwork. D. Duct sealing system: Equivalent to United McGill “Uni-Weather” UL listed sealant. Fire rating: UL listed. Contractor may propose alternate sealing systems. “Ductmate” and similar flanged joining systems are acceptable. E. Construct and seal ducts to 3” static pressure standards. Plumbing 1. Support pipe with rod and clevis, ring hangers, trapeze, or clamps. No pipe tape or strapping allowed. All hangers shall be sized for OD of insulation, if any. Protect insulated lines with 20 ga sheet metal shields and provide calcium silicate insulation inserts for all insulated piping. Maintain vapor barrier on all cold lines. Isolate bare copper lines from hangers with Vibrasorb or equivalent, copper coated hangers are not sufficient, wrapping pipe with tape not acceptable. 2. Refer to plumbing fixture connections schedule for pipe sizes to individual plumbing fixtures. 3. Provide shock arresters at all domestic hot and cold water branches serving fixtures and equipment with quick closing valves. Such fixtures and equipment includes flush valve water closets. Shock arresters shall be constructed with a piston in a sealed copper tube chamber, and approved for installation within walls without access panels. Sioux chief or equivalent. Bellows type not acceptable. 4. Domestic hot and cold piping inside building--Type “L” hard copper water tube, wrought copper fittings and no lead 95-5 solder. 5. Copper pipe valves and specialties A. Gate valves - bronze, class 125, 200 lb. w.o.g. B. Ball valves - bronze, class 125, 600 lb. w.o.g. C. Check valves - bronze, class 125, 200 lb. w.o.g. D. Balancing valves - 125 psi w.p. For 250 degree Fahrenheit service tight shutoff, Tour and Anderson STA, Armstrong CBV, Gerand, or Flowset, B&G circuit setter. E. Direct unions: Furnish and install a dielectric union at each connection between dissimilar metals. 6. Materials; soil, waste, and vent piping (inside building) A. Lines buried below ground: Standard weight, cast iron soil pipe, and fittings. Hub and spigot with neoprene gaskets. B. Lines above ground: Standard weight, cast iron soil pipe, and fittings. Hub and spigot with neoprene gaskets, or no hub with standard clamps. Up through 2-1/2” may be standard weight, galvanized steel pipe with black, wrought iron drain fittings, or DWV copper tube with DWV fittings and 95-5 no lead solder. 7. Drain pan piping: Not buried: Type “M” copper, wrought copper fittings, and 95-5 solder; Buried: Type “L” copper wrought copper fittings, and 95-5 solder. All buried pipe shall be surrounded with 4” of clean sand. 8. Piping insulation - insulate domestic hot water with UL approved, white, all service, mineral fiber, snap-on, pipe insulation. Insulate fittings with mineral fiber blanket insulation and pre-molded PVC covers. All materials shall have a smoke developed rating of 50 or less and a flame spread rating of 25 or less. Provide calcium silicate thermal insert at hangers and supports. Insulation shall pass uninterrupted through hangers. Vapor barriers shall be continuous, and sealed with “non-breathing” vapor barrier mastic on piping operating at temperatures below ambient. All raw edges of insulation shall be neatly trimmed and sealed with mastic. A. Insulation thickness below based on insulation conductivity value not exceeding 0.27 Btu*in/(hr*ft^2*°F): 1) Domestic hot water (DHW) and domestic hot water recirculation: all pipe sizes - 2” thick; non-recirculated DHW runouts within 8 feet of fixtures - 1” thick. 9. Identification: Label all [new] piping and equipment. Provide full band or strip type markers and flow arrows on piping. Provide engraved plastic valve tags with valve number and attach with standard chain or s-hooks. Provide engraved plastic sign on or near specified equipment. Fire Protection 1. Fire protection design/build requirements: A. Provide an automatic sprinkler system. Complete drawings, specifications, and details shall be submitted by the fire sprinkler design-build contractor. B. The fire sprinkler contractor shall serve as the Engineer of record for all work performed under this division. If required by the authority having jurisdiction, (AHJ) Submit complete fire sprinkler system shop drawings and hydraulic calculations, generated by contractor. Shop drawings shall be a minimum 1/8” scale, and shall show device and appliance locations, building background information, room occupancy descriptions, door swings, fire ratings and fire protection system layout and details. Shop drawings and hydraulic calculations shall be sealed by a professional Engineer or Nicet III licensed technician registered in the state of Colorado. Submit shop drawings and hydraulic calculations to the building and fire departments and obtain their approval before submission to the architect. C. Where required by the AHJ, all sprinkler heads should have the connecting main and branch pipe sizes shown. 1) Show the connecting main and branch pipe sizes for all sprinkler heads. 2) Conform to light hazard occupancy requirements of NFPA 13. 3) Provide flow test indicating static and residual pressured developed under fire flow conditions as required by AHJ. D. System shall be installed complete and operational, including water flow indicator, connections to alarm, drain piping, identification signs, etc. E. Work shall be performed by a qualified fire sprinkler installer with a minimum of five (5) years experience in similar installations. F. Coordinate all work with all other trades prior to and during installation. MECHANICAL SPECIFICATIONS G NEW GAS LINE TO VALVE BOX WEATHER PROOF VALVE/CONTROL BOX. CONTRACTOR TO PROVIDE/INSTALL IF NOT BUILT-IN TO SPECIFIED EQUIPMENT. CONNECT GAS LINE TO APPLIANCE IN VALVE BOX. PROVIDE DEDICATED SHUTOFF VALVE AT EACH APPLIANCE. T INSTALL THERMOSTAT FOR EF-1 CONTROL BEHIND MEDIA WALL IN CEILING COVE. NO SCALE EXTERIOR SINK PIPING DIAGRAM SINK CABINETRY EXISTING DOMESTIC MAIN IN PARKING GARAGE C NEW DOMESTIC LINES TO OUTDOOR SINKS, TYP. CONNECT DOMESTIC LINES TO SINK FIXTURE. PROVIDE SHUTOFF AND DRAIN AT BOTTOM OF PIPE STACK FOR SINK DRAINAGE (WINTERIZATION). PRV AND UNIT CONNECTION BY EQUIPMENT MANUFACTURER. PROVIDE VALVES/FITTINGS AS REQUIRED TO MEET MANUFACTURER'S REQUIREMENTS. Designed: Reviewed: Project No: 8234.15 SEAL Issued: 25% DD SET 07/10/2017 S:\BGPROJECTS\8234.15 RITZ CARLTON - VAIL - LOUNGE RENOVATION\DRAWINGS\8234.15M4.0.DWG03.15.186:43:10 PM Scale: As ShownRITZ CARLTON VAIL LOUNGE RENOVATION728 W LIONSHEAD CIRVAIL, COLORADO 81657Sheet Title: Sheet No: Date: © 2016 BG BUILDINGWORKS INC. Current Issue: BUILDING PERMIT ALBUQUERQUE | AVON | DENVER | FORT COLLINS303.278.3820 www˛bgbuildingworks˛com03.15.2018 BUILDING PERMIT 03/15/2018 25% CD SET 09/25/2017 75% DD SET 08/21/2017 75% CD SET 12/04/2017 Edwards, CO 81632 Vail CO 81658.1734 105 Edwards Village Blvd, Suite G104 (970) 949.7034 email: general@vagarchitects.com Post Office Box 1734 Judge + Architects + Planners Associates MECHANICAL DIAGRAMS DAL DAL M4.0 08/21/18