Loading...
HomeMy WebLinkAboutB18-0346_Approved Plans_1535042503.pdfA1.0 Lower Level Notes - Upgrade lighting/ electrical per lighting design -Add Wood Wall paneling at red dotted locations -Add window blinds where indicated General Notes- -Interior Remodel- No exterior work -All Work to comply with 2015 IBC 08/23/18 A2.0 Main Level Notes -Upgrade lighting/ electrical per lighting design -Replace kitchen cabinet/ countertops- similar layout- no plumbing changes -Replace powder room vanity/ countertop- no plumbing changes -Add Wood Wall paneling at red dotted locations -Add window blinds where indicated 08/23/18 A3.0 Upper Level Notes -Upgrade lighting/ electrical per lighting design -Add Wood Wall paneling at red dotted locations -Add window blinds where indicated 08/23/18 S RECÁMARA 02 FAMILY RECÁMARA 01 04 B[40] B [40] ID1.1 ID1.1 L3 L3 L2 L2 L2 R6 R8W R7 R7 B[40] B [40] F SA1.1 SA1.1 B [40] B[40] B[40] B [40] B [25] B [25] B [25] B [25] R6 R7 R7 R8W B [40] B [40] F 01 02 03 05 09 06 pico 07SA1.2 SA1.2 08 pico L2 B [40] B[25] B [40] B [40] B [25] B [25] B [40] B [40] B [40] B [40] B [40] B [40] VS SPS D5 LT6.1 PS VSS1 7 7 6 6 PS PS PS PS 7 8 8 3 PS 1 1 1 PS 1 PS 1 PS 7 8 8 2 LM-ALM-A 2 LM-B 2 D5 LT6.1 D5 LT6.1 D1 LT6.1 D7 LT6.1 D2 LT6.1 D1 LT6.1 D7 LT6.1LM-A 2 LM-B 2 D2 LT6.1 R8 B [40] B [40] B [40] SSSS(3)R6 (3)R6 R6 UPLIGHT AND SHELF LIGHTS PS 7 PS 7 3'-0"J J LOCATION FOR REMOTE POWER SUPPLY FOR LINEAR LED FIXTURES TYPE 'L' AND 'R*' BY EC. 24V DC DIMMABLE POWER SUPPLY TO BE SIZED ACCORDING TO LOAD ATTACHED, REFER TO MANUFACTURER INSTALLATION INSTRUCTIONS. CONSTANT HOT OUTLET WITH LUTRON LAMP MODULE FOR CONTROL OF FLOOR/TABLE LAMP. EXACT OUTLET LOCATION TO BE COORDINATED WITH INTERIORS/ARCHITECT. BEDSIDE KEYPAD TO BE RADIO FREQUENCY "PICO" UNIT. PEDESTAL FOR MOUNTING PROVIDED WITH UNIT. E.C. TO PROVIDE CONTROL CIRCUIT FOR FIREPLACE IGNITOR. E.C. TO VERIFY CONNECTION AND OPERATING REQUIREMENTS VIA CONTROL SYSTEM WITH FIREPLACE MANUFACTURER. BEDSIDE KEYPAD TO BE RADIO FREQUENCY TABLETOP UNIT. OUTLET FOR PLUG IN REQUIRED. SCONCE HEIGHT TO BE DETERMINED. LOCATION TO BE COORDINATED WITH INTERIORS/ ARCHITECT. LOCATION FOR REMOTE POWER SUPPLY FOR LINEAR LED FIXTURES TYPE 'L2' BY EC. 24V DC SWITCHED POWER SUPPLY TO BE SIZED ACCORDING TO LOAD ATTACHED, REFER TO MANUFACTURER INSTALLATION INSTRUCTIONS. SWING ARM LIGHT FIXTURE TO BE SELF-SWITCHED. LOCATION TO BE COORDINATED WITH INTERIORS/ ARCHITECT. DETAIL NOTES 1 2 3 4 5 6 7 8 SCALE: 1/4"=1'-0" LOWER LEVEL LIGHTING PLAN1 LT1.1 Issue: DESCRIPTION SHEET www.robertsingerlighting.com ROBERT SINGER & ASSOCIATES INC. PROJECT po box 8929 aspen_co 81621 po box 26344 scottsdale_az 85255 © 2016 ROBERT SINGER & ASSOCIATES INC. NOTE: ALL DESIGNS, IDEAS, AND CONCEPTS DEVELOPED IN THISDRAWING SHALL REMAIN AT ALL TIMES THE SOLE PROPERTY OF ROBERT SINGER & ASSOCIATES INC. ALL DRAWINGS ARE BASED ON INFORMATION SUPPLIED TO R.S.A. BY THE ARCHITECT/DESIGNER. ALL SITE SPECIFIC CONDITIONS ANDDIMENSIONS TO BE CONTRACTOR VERIFIED. CONTRACTOR ASSUMPTION OF ALL RESPONSIBILITY IS HERE INFERRED AND ANY INTERPRETATION OF DRAWINGS IS TO BE CONFIRMED BY DESIGNER. ALL WORK MUST BE IN COMPLETE ACCORDANCE WITH ALL CODES, REGULATIONS, AND REQUIREMENTS OF ALL GOVERNING AUTHORITIES HAVING JURISDICTION OVER THIS WORK INCLUDING LOCAL UTILITIES, AND IN ACCORDANCE WITH FIRE UNDERWRITERS REQUIREMENTS. THE ABOVE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTEDTHEREBY ARE AND SHALL REMAIN THE PROPERTY OF THE DESIGNER AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE DESIGNERS. VISUAL CONTACT WITH THESE PLANS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. Corporate Member IALD, IES DESIGN CONSULTANTS LIGHTING SPECIALISTS 655 e. valley rd. suite 200 basalt_co 81621 SCALE: T 970_963_5692 F 970_963_5684 NORTH 3 GCP INC. --VAIL, CO LOWER LEVEL LIGHTING PLAN 1/4"=1'-0" LT1.1 06.13.2018 INITIAL DESIGN 06.15.2018 PERMIT SET 08.09.2018 COORDINATION SET 08/23/18 COMEDOR SALA COCINA GALERÍA PAL. DESAYUNADOR S B R6 R7 F L E E BW [40] B [40] BW [40] BW [40] BW [40] BW [40] BW [40] B [40] B[40]R7 BW [40] B [25] B [25] B [40] B [40]ID2.2 L2 11 12 13 14 15 16 17 FP ID2.3 ID2.3 B [40] R6 B [25] B [25] R6 R6 B [25] B [25] PS 1 PS 1 PS 1 PS 1 PS 1 6 6 PS 7 PS 1 D1 LT6.1 D7 LT6.1 D6 LT6.1 LM-A 2 LM-B 2 4 D3 LT6.1 D3 LT6.1 D10 LT6.1 TO BELOW T1 T1 TA TA TA TA TA ID2.4 6 ID2.4 6 R9 ID2.1 LM-C 2 CO CO 9 9 B [40] B [40]SSLSLSL T1CT1C T1C TA T1C T1 T1 TA TA TA TA TA TA TA TA J TO ABOVE LOCATION FOR REMOTE POWER SUPPLY FOR LINEAR LED FIXTURES TYPE 'L' AND 'R*' BY EC. 24V DC DIMMABLE POWER SUPPLY TO BE SIZED ACCORDING TO LOAD ATTACHED, REFER TO MANUFACTURER INSTALLATION INSTRUCTIONS. CONSTANT HOT OUTLET WITH LUTRON LAMP MODULE FOR CONTROL OF FLOOR/TABLE LAMP. EXACT OUTLET LOCATION TO BE COORDINATED WITH INTERIORS/ARCHITECT. BEDSIDE KEYPAD TO BE RADIO FREQUENCY "PICO" UNIT. PEDESTAL FOR MOUNTING PROVIDED WITH UNIT. E.C. TO PROVIDE CONTROL CIRCUIT FOR FIREPLACE IGNITOR. E.C. TO VERIFY CONNECTION AND OPERATING REQUIREMENTS VIA CONTROL SYSTEM WITH FIREPLACE MANUFACTURER. BEDSIDE KEYPAD TO BE RADIO FREQUENCY TABLETOP UNIT. OUTLET FOR PLUG IN REQUIRED. SCONCE HEIGHT TO BE DETERMINED. LOCATION TO BE COORDINATED WITH INTERIORS/ ARCHITECT. LOCATION FOR REMOTE POWER SUPPLY FOR LINEAR LED FIXTURES TYPE 'L2' BY EC. 24V DC SWITCHED POWER SUPPLY TO BE SIZED ACCORDING TO LOAD ATTACHED, REFER TO MANUFACTURER INSTALLATION INSTRUCTIONS. SWING ARM LIGHT FIXTURE TO BE SELF-SWITCHED. LOCATION TO BE COORDINATED WITH INTERIORS/ ARCHITECT. CLOCK OUTLET, ~66"AFF, TO BE CONFIRMED AND COORDINATED WITH INTERIORS. DETAIL NOTES 1 2 3 4 5 6 7 8 9 SCALE: 1/4"=1'-0" MIDDLE LEVEL LIGHTING PLAN1 LT1.2 Issue: DESCRIPTION SHEET www.robertsingerlighting.com ROBERT SINGER & ASSOCIATES INC. PROJECT po box 8929 aspen_co 81621 po box 26344 scottsdale_az 85255 © 2016 ROBERT SINGER & ASSOCIATES INC. NOTE: ALL DESIGNS, IDEAS, AND CONCEPTS DEVELOPED IN THISDRAWING SHALL REMAIN AT ALL TIMES THE SOLE PROPERTY OF ROBERT SINGER & ASSOCIATES INC. ALL DRAWINGS ARE BASED ON INFORMATION SUPPLIED TO R.S.A. BY THE ARCHITECT/DESIGNER. ALL SITE SPECIFIC CONDITIONS ANDDIMENSIONS TO BE CONTRACTOR VERIFIED. CONTRACTOR ASSUMPTION OF ALL RESPONSIBILITY IS HERE INFERRED AND ANY INTERPRETATION OF DRAWINGS IS TO BE CONFIRMED BY DESIGNER. ALL WORK MUST BE IN COMPLETE ACCORDANCE WITH ALL CODES, REGULATIONS, AND REQUIREMENTS OF ALL GOVERNING AUTHORITIES HAVING JURISDICTION OVER THIS WORK INCLUDING LOCAL UTILITIES, AND IN ACCORDANCE WITH FIRE UNDERWRITERS REQUIREMENTS. THE ABOVE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTEDTHEREBY ARE AND SHALL REMAIN THE PROPERTY OF THE DESIGNER AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE DESIGNERS. VISUAL CONTACT WITH THESE PLANS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. Corporate Member IALD, IES DESIGN CONSULTANTS LIGHTING SPECIALISTS 655 e. valley rd. suite 200 basalt_co 81621 SCALE: T 970_963_5692 F 970_963_5684 NORTH 3 GCP INC. --VAIL, CO MIDDLE LEVEL LIGHTING PLAN 1/4"=1'-0" LT1.2 06.13.2018INITIAL DESIGN 06.15.2018 PERMIT SET 08.09.2018 COORDINATION SET 08/23/18 L D8 LT6.1 B RECÁMARA PRINCIPAL RECÁMARA 03 B[25] B [25] B [25] B [40] B[25] B[25] SA3.1SA3.1 26pico B[40] B [25] R8W BC [40] BC [40] B [40] B [40] R6 R7 R7 R7 R7 L L L BC[40]BC [40] R8W L2 B [40] B [40] SA3.2 SA3.2B [40] B [40] B [40] F R6 R7 R7 21 22 24 23 pico B[25] ID3.2 R4 2 BW [25] BW [25] BW [25] BW [25] BW [25] R2 BW [25] PS 1 LM-A 2 LM-B 2 8 8 PS 1 25 27pico 28 29 30 LM-A 2 LM-B 8 8 PS 7 D5 LT6.1 PS 1 PS 1 PS 1 PS 1 PS 1 PS 1 PS 1 D2 LT6.1 D2 LT6.1 D6 LT6.1 D7 LT6.1 D1 LT6.1 D1 LT6.1D7 LT6.1 LM-C 2 LM-C 2 ID3.1 R8 R8 R9 R2 R2 BW [25] BW [25] R9 R9 TO BELOW SLSLSL PS1 PS 1 PS 1 J F F SPS1 J J J R9 D10 LT6.1 D10 LT6.1 D10 LT6.1 D9 LT6.1 LOCATION FOR REMOTE POWER SUPPLY FOR LINEAR LED FIXTURES TYPE 'L' AND 'R*' BY EC. 24V DC DIMMABLE POWER SUPPLY TO BE SIZED ACCORDING TO LOAD ATTACHED, REFER TO MANUFACTURER INSTALLATION INSTRUCTIONS. CONSTANT HOT OUTLET WITH LUTRON LAMP MODULE FOR CONTROL OF FLOOR/TABLE LAMP. EXACT OUTLET LOCATION TO BE COORDINATED WITH INTERIORS/ARCHITECT. BEDSIDE KEYPAD TO BE RADIO FREQUENCY "PICO" UNIT. PEDESTAL FOR MOUNTING PROVIDED WITH UNIT. E.C. TO PROVIDE CONTROL CIRCUIT FOR FIREPLACE IGNITOR. E.C. TO VERIFY CONNECTION AND OPERATING REQUIREMENTS VIA CONTROL SYSTEM WITH FIREPLACE MANUFACTURER. BEDSIDE KEYPAD TO BE RADIO FREQUENCY TABLETOP UNIT. OUTLET FOR PLUG IN REQUIRED. SCONCE HEIGHT TO BE DETERMINED. LOCATION TO BE COORDINATED WITH INTERIORS/ ARCHITECT. LOCATION FOR REMOTE POWER SUPPLY FOR LINEAR LED FIXTURES TYPE 'L2' BY EC. 24V DC SWITCHED POWER SUPPLY TO BE SIZED ACCORDING TO LOAD ATTACHED, REFER TO MANUFACTURER INSTALLATION INSTRUCTIONS. SWING ARM LIGHT FIXTURE TO BE SELF-SWITCHED. LOCATION TO BE COORDINATED WITH INTERIORS/ ARCHITECT. DETAIL NOTES 1 2 3 4 5 6 7 8 SCALE: 1/4"=1'-0" UPPER LEVEL LIGHTING PLAN1 LT1.3 Issue: DESCRIPTION SHEET www.robertsingerlighting.com ROBERT SINGER & ASSOCIATES INC. PROJECT po box 8929 aspen_co 81621 po box 26344 scottsdale_az 85255 © 2016 ROBERT SINGER & ASSOCIATES INC. NOTE: ALL DESIGNS, IDEAS, AND CONCEPTS DEVELOPED IN THISDRAWING SHALL REMAIN AT ALL TIMES THE SOLE PROPERTY OF ROBERT SINGER & ASSOCIATES INC. ALL DRAWINGS ARE BASED ON INFORMATION SUPPLIED TO R.S.A. BY THE ARCHITECT/DESIGNER. ALL SITE SPECIFIC CONDITIONS ANDDIMENSIONS TO BE CONTRACTOR VERIFIED. CONTRACTOR ASSUMPTION OF ALL RESPONSIBILITY IS HERE INFERRED AND ANY INTERPRETATION OF DRAWINGS IS TO BE CONFIRMED BY DESIGNER. ALL WORK MUST BE IN COMPLETE ACCORDANCE WITH ALL CODES, REGULATIONS, AND REQUIREMENTS OF ALL GOVERNING AUTHORITIES HAVING JURISDICTION OVER THIS WORK INCLUDING LOCAL UTILITIES, AND IN ACCORDANCE WITH FIRE UNDERWRITERS REQUIREMENTS. THE ABOVE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTEDTHEREBY ARE AND SHALL REMAIN THE PROPERTY OF THE DESIGNER AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE DESIGNERS. VISUAL CONTACT WITH THESE PLANS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. Corporate Member IALD, IES DESIGN CONSULTANTS LIGHTING SPECIALISTS 655 e. valley rd. suite 200 basalt_co 81621 SCALE: T 970_963_5692 F 970_963_5684 NORTH 3 GCP INC. --VAIL, CO UPPER LEVEL LIGHTING PLAN 1/4"=1'-0" LT1.3 06.13.2018INITIAL DESIGN 06.15.2018 PERMIT SET 08.09.2018 COORDINATION SET 08/23/18 2" FLOOR TO BE MATTE FINISH TO PREVENT REFLECTION. 1"916"916"FIXTURE TYPE 'R6' LINEAR LED. REMOTE POWER SUPPLY LOCATION BY EC. WALL AND COVE SURFACE TO BE MATTE FINISH TO PREVENT REFLECTION.114"FIXTURE TYPE 'R8'/'R8W'. (2) RUNS OF LINEAR LED RIBBON IN ALUMINUM CHANNEL RUN VERTICALLY. REMOTE POWER SUPPLY LOCATION BY EC.4"34"3/4" VALENCE TO CONCEAL FIXTURE34"FIXTURE TYPE 'R6' LINEAR LED. REMOTE POWER SUPPLY LOCATION BY EC. 1" 3 4" FIXTURE TYPE 'R2'. ROUTE 1/2" DEEP X 1" WIDE CHANNEL TO HOUSE FIXTURE. REMOTE POWER SUPPLY LOCATION BY EC. COUNTER SURFACE BAR FACE 2"1"1" LED CLOSET FIXTURE TYPE 'L2' WITH IN-LINE MOTION DETECTOR. BRACKET MOUNTED TO WALL AT CEILING TRANSITION. E.C. TO PROVIDE LOCATION FOR REMOTE POWER SUPPLY. CLOSET ROD WALL SURFACE 1-12" MIN. VALENCE SHELVING 134"114"LED CLOSET FIXTURE TYPE 'L'. E.C. TO PROVIDE LOCATION FOR DIMABLE REMOTE POWER SUPPLY 1" 13 16"58"FIXTURE TYPE 'R8'. (2) RUNS OF LINEAR LED RIBBON IN ALUMINUM CHANNEL RUN VERTICALLY. REMOTE POWER SUPPLY LOCATION BY EC. MIRROR. FROSTED GLASS. 312" DRYWALL. MIRROR FROSTED GLASS ELEVATION VIEW PLAN VIEW 2"114"MIRROR ~3" BEAM FIXTURE TYPE 'R2' REMOTE POWER SUPPLY LOCATION BY EC.1"1116"2" 1116" FIXTURE TYPE 'R4' LINEAR LED. REMOTE POWER SUPPLY LOCATION BY EC TO BE COORDINATED WITH INTERIORS AND ARCHITECT. SKIM COAT ALONG PLASTER FLANGE FOR SEAMLESS APPREARANCE. 315 16"58"FIXTURE TYPE 'R9' LINEAR LED. REMOTE POWER SUPPLY LOCATION BY EC TO BE COORDINATED WITH INTERIORS AND ARCHITECT. SKIM COAT ALONG PLASTER FLANGE FOR SEAMLESS APPREARANCE. Issue: DESCRIPTION SHEET www.robertsingerlighting.com ROBERT SINGER & ASSOCIATES INC. PROJECT po box 8929 aspen_co 81621 po box 26344 scottsdale_az 85255 © 2016 ROBERT SINGER & ASSOCIATES INC. NOTE: ALL DESIGNS, IDEAS, AND CONCEPTS DEVELOPED IN THIS DRAWING SHALL REMAIN AT ALL TIMES THE SOLE PROPERTY OF ROBERT SINGER & ASSOCIATES INC. ALL DRAWINGS ARE BASED ON INFORMATION SUPPLIED TO R.S.A. BY THE ARCHITECT/DESIGNER. ALL SITE SPECIFIC CONDITIONS AND DIMENSIONS TO BE CONTRACTOR VERIFIED. CONTRACTOR ASSUMPTION OF ALL RESPONSIBILITY IS HERE INFERRED AND ANY INTERPRETATION OF DRAWINGS IS TO BE CONFIRMED BY DESIGNER. ALL WORK MUST BE IN COMPLETE ACCORDANCE WITH ALL CODES, REGULATIONS, AND REQUIREMENTS OF ALL GOVERNING AUTHORITIES HAVING JURISDICTION OVER THIS WORK INCLUDING LOCAL UTILITIES, AND IN ACCORDANCE WITH FIRE UNDERWRITERS REQUIREMENTS. THE ABOVE DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF THE DESIGNER AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE DESIGNERS. VISUAL CONTACT WITH THESE PLANS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. Corporate Member IALD, IES DESIGN CONSULTANTS LIGHTING SPECIALISTS 655 e. valley rd. suite 200 basalt_co 81621 SCALE: T 970_963_5692 F 970_963_5684 3 GCP INC. VAIL, CO LIGHTING DETAILS SEE DETAIL LT6.1 SCALE: 3" = 1'-0" FLOATING VANITY CONCEPTD1 LT6.1 SCALE: 3" = 1'-0" WALL WASHD2 LT6.1 SCALE: 3" = 1'-0" UNDERCOUNTER LIGHTINGD3 LT6.1 SCALE: 3" = 1'-0" BAR FACEWASHD4 LT6.1 SCALE: 3" = 1'-0" CLOSET DOORBUCKD5 LT6.1 SCALE: 3" = 1'-0" CLOSET SHELF LIGHTINGD6 LT6.1 SCALE: 3" = 1'-0" VERTICAL VANITY CONCEPTD7 LT6.1 SCALE: 3" = 1'-0" BEAM UPLIGHTD8 LT6.1 06.13.2018 INITIAL DESIGN 06.15.2018 PERMIT SET 08.09.2018 COORDINATION SET SCALE: 3" = 1'-0" PLASTER-IN CEILING LIGHTD9 LT6.1 SCALE: 3" = 1'-0" PLASTER-IN WALL LIGHTD10 LT6.1 08/23/18