HomeMy WebLinkAboutB18-0304_Approved Documents_1535652432.pdf75 South Frontage Road
West,
Vail, CO 81657
Office: 970.479.2139
Inspections:
inspections@vailgov.com
Construction
B18-0304
Issued: 08/30/2018
TOWN OF VAIL
Property Information
Address: 4552 MEADOW DR 27 (210112421027 27) ( 210112421027 )
Unit #: 27
Parcel Number: 210112421027
Legal Description: DESC: PHASE III Subdivision: COURTSIDE TOWNHOMES Unit: 27 BK-0442 PG-0946 QCD 05-30-86
Contacts
Contact Type: Applicant
Full Name: Tony Parra
Address: 4552 Meadow Dr 27 Vail, CO 81657 Phone: 9709496341
Contact Type: Property Owner
Full Name: VAIL COURTSIDE 27 LLC
Address: Phone: None
Contractor
Contractor Type: General
Company: Ankerholz Inc.
State License #: Phone: 970-949-6341
Project Information
Project Name: Vail Courtside 27 LLC 2018
Project Description: Add new bathroom at main level and install a new gas fireplace
Fees Paid
Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$441.75
Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$287.14
Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$400.00
Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$20.00
Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$5.00
Account #: 001-0000.31111.00 - Plumbing Permit Fee Fee Amount:$75.00
Account #: 001-0000.31123.00 - Plumbing Plan Review Fee Fee Amount:$18.75
Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00
Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00
Account #: 001-0000.31128.00 - Will Call Fee (Plumbing Scope)Fee Amount:$5.00
Total Paid:$1,262.64
Conditions
CONDITIONS UNDER WHICH PERMITS BECOME VOID:
If construction is not begun within 6 months from the date permit was issued.
If more than 5 months elapses between inspections.
If incorrect information is given on the application at the time the permit was issued.
Christopher Jarecki - Town of Vail Building Official
NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal
law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees.
PERMIT FEE RECEIPT
Case # B18-0304
Date Printed: 08/30/2018
TOWN OF VAIL - FEES RECEIPT
Permit Summary
Case Number: B18-0304 Status: Approved
Permit Number: Date Started: 07/23/2018
Permit Type: Construction Subcases Single Family
Lot Number:
Property: 4552 MEADOW DR 27 (210112421027 27) (210112421027)
Contacts
Contact Type: Applicant
Company Name: Ankerholz Inc.
Full Name: Tony Parra
Address: 4552 Meadow Dr 27 Vail, CO 81657
Email: ankerholzinc@yahoo.com
Contact Type: Property Owner
Full Name: VAIL COURTSIDE 27 LLC
Address:
Permit Fees
Fee Information Account Amount
Permit Fee 001-0000.31111.00 $536.75
Construction Tax 110-0000.31060.00 $400.00
Will Call Fee 001-0000.31128.00 $15.00
Payment Information Date Paid Payment Type Amount
Permit Fee 08/30/2018 Check $536.75
Paid By: Ankerholz Incorporated - Notes: ck#5819
Will Call Fee 08/30/2018 Check $15.00
Paid By: Ankerholz Incorporated - Notes: ck#5819
Construction Tax 08/30/2018 Check $400.00
Paid By: Ankerholz Incorporated - Notes: ck#5819
FEE TOTAL $951.75
AMOUNT PAID $951.75
BALANCE DUE $0.00
08/30/2018 - 11:59:30 AM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657
1 / 1
August 14, 2018
Mr. TonyParra
OP Box 296
Avon CO
970-376-3451
ankerholzinc@yahoo.com
RE: Summery letter report of August 9, 2018 construction specific Asbestos Inspection to
facilitate drywall demolition for a bathroom remodel project at 4552 Meadow Drive, Vail
Colorado.
Dear Mr. Parra,
The Scope of Work for this project included a visual inspection, sample collection of
suspect and analysis of the material in question at the Residence. This Scope of Work
was performed by Mr. Robert Ragan of R2 Analytical an EPA and State of Colorado
Certified Asbestos Building Inspector# 3143.
Inspecting Sampling Scope of Work:
Identify & collect samples of suspect asbestos containing material (ACM) in areas
designated for renovation by the client.
Provide laboratory analysis of suspect ACM
Provide report of findings.
Methodology
Field Work:
The construction specific asbestos survey was performed by collecting samples from
suspect ACM to be impacted by this project. This survey was conducted in general
accordance with EPA National Emissions Standards for Hazardous Air Pollutants
(NESHAPS) and the Occupational Safety and Health Administration’s (OSHA)
regulation 29 CFR 1926.1101.
A material is considered by the Environmental Protection Agency (EPA) and the State of
Colorado to be asbestos-containing if at least one sample collected from the homogenous
material has asbestos present in a concentration greater than one percent (>1 %).
R2 Analytical
5177 South Ventura Way
Centennial, CO 80015
303-210-1349 Fax 303-632-8226
rragan2@comcast.net
R2 Analytical
All samples were submitted to Reservoirs Environmental, Inc., under proper chain-of-
custody procedures, for analysis of asbestos content on 2-hour turn-around. Reservoirs
Environmental, Inc. participates in the National Voluntary Laboratory Accreditation
Program (NVLAP).
ACM Sample Findings
Bulk samples were collected from the following building material;
Homogeneous area A- Textured drywall from the walls from the walls and
ceiling in the bathroom to be remodeled
A total of 3 samples were collected from one (1) identified homogenous
Of the three samples collected, asbestos was not detected by laboratory analysis.
The textured drywall may be altered or demolished without special engineering
controls.
Please refer to the attached RES report 415618-1 for Laboratory Analysis of bulk
samples
CONCLUSIONS AND RECOMMENDATIONS
R2 Analytical recommends the building material identified and sampled in this survey can
be demolished or altered without special engineering controls.
*It should be noted building materials discovered during demolition that have not been
analyzed at 4552 Meadow Drive Vail Colorado must be assumed asbestos, until tested
and proven otherwise. Any material not identified that will be impacted by renovation
/remodel activities must be removed in accordance with the State of Colorado Regulation
8 Part B and OSHA.
Please contact R2 Analytical at your convenience, if you have any question related to
this or any other project.
Robert L. Ragan
Industrial Hygienist
R218-120-
4552 Meadow Drive Vail Colorado
CONSTRUCTION SPECIFIC
ASBESTOS INSPECTION SUMMARY TABLE #1
DATE SAMPLED: 5-2-18
Material
Condition ACM
Type &Description Quantity of AHERA Greater
Sample Number Sample Location of Sampled Material Material Code 1-8 Than 1%
4552MD-DWT-A1 Bathroom wall Textured Drywall Approx.
300 sq ft
NR No
8610M-B-PCT-A2 Bathroom Ceiling Textured Drywall AA NR No
8610M-B-PCT-A3 Bathroom wall by entrance Textured Drywall AA NR No
AHERA CODE:
(1) D/SD TSI = Damaged/Significantly Damaged Thermal (6) PSD ACM = Potential for Significant damage Asbestos Containing Material
System Insulation (7) F ACM G = Friable Asbestos Containing Material in Good Condition
(2) D FSM = Damaged Friable Surfacing Material (8) NF ACM G = Non-Friable Asbestos Containing Material in Good Condition
(3) SD FSM = Significantly Damaged Friable Surface Material
(4) D/SD FMM = Damaged/Significantly Damaged
Friable Miscellaneous Material MATERIAL TYPE: MM = Miscellaneous Materials TSI = Thermal System Insulation SM = Surfacing Material
(5) PD ACM = Potential for Damage Asbestos NA = Not Available AA = As Above NR Not Required
Containing Material
A
B N
C
D
E
F
G
H
Q
I
J
K
POWERGAS SUPPLY
L
M
O H
I J
P
P/PL Series
PART ACTUAL FRAMING
FRONT WIDTH 42” 42”
BACK WIDTH 39¾” 42”
HEIGHT 34⅝” 42’’
DEPTH 20⅝” 21⅞’’
VIEWING AREA 39½” X 20¼” N/A
LINEAR GAS FIREPLACE DIMENSIONS
SPEC SHEET
PL42 & P42
TECHNICAL SPECIFICATIONS
TOP
FRONT LEFT RIGHT
A B C D E F G H I J K
PL38DF
P38DF 37¾" 29½" 35¼" 19⅜" 4⅝" 5½" 33¾" 19½" 5" 8" 26⅜"
PL42DF
P42DF 42" 30½" 39½" 20¼" 4¾" 5½" 34⅝" 20⅝" 5" 8" 27⅜"
L M N O P Q
PL38DF
P38DF 35½" 11⅝" 36⅝" 22⅛" 39¼" 20¼"
PL42DF
P42DF 39¾" 12⅝" 37¾" 23⅛" 43⅝" 21¼"
FEATURES
• Convertible to top or rear vent
• Snap-lock door for access to
firebox
• Power vent capable
• Flush screen barrier
P42 Comes standard with:
• Concealed ribbon burner with multiple
media options
• Black porcelain firebox liner
• Accent up-lighting
• Multi-speed fans
• Full function remote control for flame
modulation, thermostatic control, light
on/off control, and fan speed control
• Battery backup for continuous
operation during power failure
P42 Options:
• Designer speckled stones, firestones,
or fireglass
• Driftwood logset available to accent
any media option
• Fireplace surround in satin black or
stainless steel
PL42 Comes standard with:
• Concealed ribbon burner with multiple
media options
PL42 Options:
• Designer speckled stones, firestones,
or fireglass
• Driftwood logset to accent any media
option
• Fans equipped with speed control
• Black porcelain firebox liner
• Fireplace surround in satin black or
stainless steel
• Full function remote control for flame
modulation
The perfect
combination of
performance
and design
FRAMING SPECIFICATIONS
CLEARANCE SPECIFICATIONS
• Sides: 0”
• Back: 0”
• Top - Top Vent: 9”
• Top - Rear Vent: 17 ½”
• Floor: 0”
LINEAR GAS FIREPLACE
P/PL Series
PL42 & P42
24 1/2
52
43
37 ½
A
B
C
D
Noncombustible
Stud
9
8 1" cl 5
2
69 1/4E
F 1'' clearanceto corners onlyG
SPEC SHEET
P42, PL42
A 42''
B 35''
C 42''
D 21 ⅞''
E 84 ½''
F 42''
G 59 ¾''