Loading...
HomeMy WebLinkAboutB18-0372_Approved Plans_1537194824.pdf∆ ∆ ∆ 8606.92 8606.78 8607.37 8590.98 8593.26 8592.91 8590.36 8606.42 8606.75 8597.51 8607.31 8607.16 TOPOGRAPHIC MAPPARCEL A & PARCEL BFINAL PLAT, A RESUBDIVISION OF LOT 8, BLOCK 1GORE CREEK SUBDIVISIONTOWN OF VAIL, EAGLE COUNTY, COLORADO09/17/18 CONSTRUCTION DOCUMENTS NOTE: THESE CONSTRUCTION DOCUMENTS INCLUDING ARCHITECTURAL SHEETS HAVE BEEN PREPARED IN RESPONSE TO THE SPECIFIC BASIC SERVICES REQUESTED BY THE OWNER CONTEMPLATING CONTINUED INVOLVEMENT, SELECTIONS AND DECISION MAKING BY THE GENERAL CONTRACTOR AND OWNER THROUGH COMPLETION OF CONSTRUCTION. THESE DOCUMENTS INDICATE THE SCOPE OF ARCHITECTURAL DESIGN CONCEPTS APPROVED BY THE OWNER AND INCLUDE DIMENSIONS OF THE BUILDING, THE TYPES OF STRUCTURAL SYSTEMS AND AN OUTLINE OF THE ARCHITECTURAL AND STRUCTURAL ENGINEERING ELEMENTS OF CONSTRUCTION. THESE CONSTRUCTION DOCUMENTS PROVIDE THE SCOPE OF SERVICES AS OUTLINED IN THE AGREEMENT FOR ARCHITECTURAL SERVICES AND THEREFORE DO NOT NECESSARILY INDICATE OR DESCRIBE ALL MATERIALS REQUIRED FOR FULL PERFORMANCE AND COMPLETION OF THE WORK. IT IS THE UNDERSTANDING OF THE ARCHITECT AND ENGINEER THAT THE GENERAL CONTRACTOR SHALL FURNISH ALL WORK REQUIRED FOR PROPER COMPLETION OF THE WORK AND THAT THE WORK SHALL BE OF SOUND AND QUALITY CONSTRUCTION IN ACCORDANCE WITH INDUSTRY STANDARDS AND ALL MANUFACTURERS SPECIFICATIONS, INSTRUCTIONS, AND WARRANTY REQUIREMENTS. THE CONTRACTOR, BASED ON THE FOREGOING, SHALL PREPARE FOR OWNER REVIEW A REALISTIC BUDGET WITH A LATITUDE OF PRICES BASED ON ASSUMPTIONS OF SCOPE OF WORK AND OWNER PRODUCT SELECTIONS. CONTRACTOR'S RESPONSIBILITIES: THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFYING ALL EXISTING CONDITIONS, CONSTRUCTION DOCUMENTS, STRUCTURAL DOCUMENTS, MUNICIPAL AND/OR COUNTY ZONING CODES, PERTINENT IRC 2015 CODE REQUIREMENTS, AND GENERAL SPECIFICATIONS. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL MECHANICAL AND ELECTRICAL ENGINEERING, DESIGN, SPECIFICATIONS AND DRAWINGS AS REQUIRED FOR BUILDING PERMIT AND APPROVAL BY OWNER AND ARCHITECT. COPYRIGHT RESERVATION: THE DRAWINGS, SPECIFICATIONS AND OTHER DOCUMENTS PREPARED BY THE ARCHITECT FOR THIS PROJECT ARE INSTRUMENTS OF THE ARCHITECT'S SERVICE FOR USE SOLELY WITH RESPECT TO THIS PROJECT AND, UNLESS OTHERWISE PROVIDED IN WRITING, THE ARCHITECT SHALL BE DEEMED THE SOLE AND EXCLUSIVE AUTHOR OF THESE DOCUMENTS AND SHALL RETAIN, WITHOUT LIMITATION, ALL RIGHTS, INCLUDING THE COPYRIGHT HEREOF. NO PERSON, WHETHER HAVING COME RIGHTLY INTO POSSESSION HEREOF OR OTHERWISE, SHALL EMPLOY THESE DOCUMENTS ON ANY OTHER PROJECT, NOR FOR ADDITIONS TO THIS PROJECT NOR FOR THE COMPLETION OF THIS PROJECT BY OTHERS, UNLESS WITH THE PRIOR EXPRESS WRITTEN CONSENT OF THE ARCHITECT AND UPON APPROPRIATE COMPENSATION TO THE ARCHITECT IN AN AMOUNT AND KIND SATISFACTORY TO THE ARCHITECT. THE ARCHITECT EXPRESSLY CLAIMS ALL PROPRIETARY RIGHTS IN THE MATERIAL WHICH IS ISSUED IN CONFIDENCE FOR DESIGN AND/OR CONSTRUCTION PURPOSES OF THIS PROJECT AS NOTED. THESE MATERIALS MAY NOT BE COPIED, MODIFIED, NOR EMPLOYED IN ANY WAY WITHOUT THE SPECIFIC PRIOR WRITTEN CONSENT AND PERMISSION OF THE ARCHITECT.970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS9/10/2018 10:36:40 AMA0.0COVER SHEETJG-1831 GROUSE DUPLEXPERMIT SET 8-28-189-10-18 Jarenko5128 Grouse LaneVail, CO 81657GROUSE DUPLEX 5128 GROUSE LANE, VAIL, COLORADO No. Description DateDuplex Residence Owner: Stanley & Karen Jeranko 1357 Ranch Reserve PKWY Denver, CO 80234-2529 pwdrhnd@aol.com Cell: 303-929-2679 Location: 5128 Grouse Lane A&B (Gore Creek Subdivision, Block 1, Lot 8, Parcels A & B) Parcel # Parcel A: 2099-182-12-009 Parcel B: 2099-182-12-010 Architect: John G Martin, AIA Martin Manley Architects www.martinmanleyarchitects.com john@martinmanleyarchitects.com 970-328-0592 Structural Engineer: To be Determined General Contractor: To be Determined PROJECT INFORMATION PROJECT NARRATIVE BOTH HALVES OF THE EXISTING DUPLEX LOT ARE OWNED BY ONE OWNER. IT IS THE OWNER'S INTENTION TO COMPLETELY DEMOLISH THE EXISTING SMALL DUPLEX AND BUILD A NEW AND IMPROVED MODERN DUPLEX RESIDENTIAL STRUCTURE ON THE SITE. THE EXISTING LOT-SPLIT LINE WILL BE ABANDONED AND A NEW LOT-SPLIT LINE WILL DEFINE A NEW PARCEL A AND PARCEL B. THERE WILL BE ACCESS FROM TWO LOCATIONS. HOUSE A ON PARCEL A WILL BE ACCESSED FROM THE END OF THE COULDESAC ON GROUSE LANE USING THE SAME DRIVEWAY PAN WIDTH AS THE PREVIOUS DRIVEWAY. HOUSE B ON PARCEL B WILL BE ACCESSED FROM THE ERW&SD ACCESS ROAD WITH PERMISSION FROM AN EXISTING ACCESS EASEMENT AGREEMENT FOR PARCEL B. THE DUPLEX HALVES ARE SEPERATED BY A 1 HR SEPARATION PARTY WALL ONLY. THE DESIGN OF THE HOUSE RESPONDS TO THE STEEP SITE, SWEEPING VIEWS, NEIGHBOR PRIVACY, GORE CREEK ADJACENCY, AND MOUNTAIN MODERN STYLE. Class of Work: New Construction Type of Occupancy: R-3 (DUPLEX) Type of Construction: Type V-b (Sprinklered) Levels: 2-story over walk-out basement Town of Vail Fire Dept. Notes: Smoke Detectors and Carbon Monoxide alarms must be installed IN ALL DWELLING UNITS, and be installed per 2015 IFC and VFES fire alarm installation standards. AN AUTOMATIC FIRE-SPRINKLER SYSTEM AND MONITORED FIRE ALARM MUST BE INSTALLED PER TOVAIL FIRE DEPT. REQUIREMENTS. This project falls under the jursidiction of: The Town of Vail Design Review Board and Building Department The 2015 International Residential Code (IRC 2015) The 2015 International Energy Conservation Code (IECC 2015) The 2014 National Electrical Code The Town of Vail Municipal Code including adopted amendments CODE SUMMARY FIRE DEPT. SUMMARY SITE AREA = .3885 ACRES x 43,560 SQ. FT. = 16,923 SQ. FT. SITE COVERAGE SUMMARY(BOTH HOUSES COMBINED): SITE COVERAGE - ALLOWED (20% LOT) = 3,385 S.F. SITE COVERAGE - TOTAL PROPOSED = 3,382 S.F. (19.9%) TOWN OF VAIL ZONING DISTRICT: Two-Family Residential (R) VAIL ZONING SUMMARY GRFA ALLOWED: 46% LOT AREA < 10,000 S.F. = 4,600 S.F. 38% LOT AREA < 15,000 S.F. = 1,900 S.F. 13% LOT AREA (1,923 S.F.) = 250 S.F. TOTAL GRFA ALLOWED = 6,750 S.F. GRFA - TOTAL PROPOSED = 6,634 S.F. (116 S.F. UNUSED) GRFA SPLIT: A-HOUSE (PRIMARY) A-HOUSE GRFA TOTAL = 3,466 S.F B-HOUSE (SECONDARY) B-HOUSE GRFA TOTAL = 3,168 S.F HEIGHT: ALLOWED = 33'-0" PROPOSED = 32'-10" PARKING: REQUIRED = 6 SPACES (3 SPACES EACH UNIT) PROPOSED = 6 SPACES (4 COVERED) LANDSCAPE AREA: ALLOWED = 10,153.8 S.F. (60% MIN.) PROPOSED = 10,765 S.F. (63.6%) SEE SHEET A0.2 AREAS & HEIGHTS FOR ALL AREA PLANS AND AREA SUMMARIES SEE SHEET A1.1 SITE PLAN FOR LANDSCAPE AREA SUMMARY Sheet List Sheet Number Sheet Name A0.0 COVER SHEET A0.1 ENERGY SHEET A0.2 AREAS & HEIGHTS A0.3 BASEMENT DEDUCTION A1.1 SITE PLAN - OVERALL A1.2 SITE PLAN - DEMO A1.3 LANDSCAPE PLAN A2.1 FLOOR PLAN - LOWER LEVEL A2.2 FLOOR PLAN - MAIN LEVEL A2.3 FLOOR PLAN - UPPER LEVEL A2.4 ROOF PLAN A2.5 FOUNDATION PLAN A2.6 FOUNDATION 3D A3.1 ELEVATIONS A3.2 ELEVATIONS A3.3 ELEVATIONS A4.1 A SECTIONS A4.2 B SECTIONS A4.3 A STAIR PLANS & SECTIONS A4.4 B STAIR PLANS & SECTIONS A4.5 FIREPLACE SECTIONS A4.6 PARTY WALL SECTIONS A5.1 DETAILS A5.2 WINDOW/DOOR SCHEDULES A6.1 RCP/ELEC - LOWER A6.2 RCP/ELEC - MAIN A6.3 RCP/ELEC - UPPER EAST VAIL VICINITY MAP 5128 GROUSE LANE BUILDER'S SET - GENERAL NOTES REVISION DESCRIPTIONS NOTE: RENDERINGS ARE ARTISTIC REPRESENTATIONS OF THE HOUSE DESIGN AND ARE NOT MEANT TO ACCURATELY DEPICT LANDSCAPING. PERMIT SET: 8-28-18 09/17/18 UP Radon System Radon system is to comply with Appendix F of the 2015 IRC A sub-slab depressurization system (passive) is to be designed. The vent pipe shall be a minimum dia. of 3" and extend from the permeable layer under the lowest slab with a ' T ' fitting, through the conditioned space of the homes, and out the roof. The exhaust shall be located as a penetration through the roof and located on the non-street side. This exhaust vent shall be 2'-0" above the roof surface and 10'-0" away from any openings or the adjacent building/unit. An electrical box shall be installed in an accessible location along radon sytem vertical piping so possible future vent pipe in-line fans can be added. See sections on this sheet for vertical location of Radon system. See key floor plan on this sheet for location of piping routing for Radon System. Additional notes: N1102.2.1 (R402.2.1) Ceilings with attic spaces. When Secton N1102.1.1 R-38 shall be deemed to satisfy the requirement for R-49 wherever the full height of uncompressed R-38 insulation extends over the wall top plate at the eaves. N1102.2.2 (R402.2.2) Ceilings without attic spaces. Where Secton N1102.1.1 would require insulation levels above R-30 and the design of the roof/ceiling assembly does not allow sufficient space for the required insulation, the minimum required insulation for such roof/ceiling assemblies shall be R-30. This reduction of insulation from the requirements of Secton N1102.1.1 shall be limited to 500 square feet (46 m2) or 20 percent of the total insulated ceiling area, whichever is less. N1102.2.3 (R402.2.3) Eave baffle. For air permeable insulations in vented attics, a baffle shall be installed adjacent to soffit and eave vents. Baffles shall maintain an opening equal or greater than the size of the vent. The baffle shall extend over the top of the attic insulation. The baffle shall be permitted to be any solid material. N1102.2.4 (R402.2.4) Access hatches and doors. Access doors from conditioned spaces to unconditioned spaces (e.g., attics and crawl spaces) shall be weatherstripped and insulated to a level equivalent to the insulation on the surrounding surfaces. Access shall be provided to all equipment that prevents damaging or compressing the insulation. A wood framed or equivalent baffle or retainer is required to be provided when loose fill insulation is installed, the purpose of which is to prevent the loose fill insulation from spilling into the living space when the attic access is opened, and to provide a permanent means of maintaining the installed R-value of the loose fill insulation. N1102.2.5 (R402.2.5) Mass walls. Mass walls for the purposes of this chapter shall be considered above-grade walls of concrete block, concrete, insulated concrete form (ICF), masonry cavity, brick (other than brick veneer), earth (adobe, compressed earth block, rammed earth) and solid timber/logs. N1102.2.7 (R402.2.7) Floors. Floor insulation shall be installed to maintain permanent contact with the underside of the subfloor decking. N1102.2.8 (R402.2.8) Basement walls. Walls associated with conditioned basements shall be insulated from the top of the basement wall down to 10 feet (3048 mm) below grade or to the basement floor, whichever is less. Walls associated with unconditioned basements shall meet this requirement unless the floor overhead is insulated in accordance with Sections N1102.1.1 and N1102.2.7. N1102.2.9 (R402.2.9) Slab-on-grade floors. Slab-on-grade floors with a floor surface less than 12 inches (305 mm) below grade shall be insulated in accordance with Table N1102.1.1. The insulation shall extend downward from the top of the slab on the outside or inside of the foundation wall. Insulation located below grade shall be extended the distance provided in Table N1102.1.1 by any combination of vertical insulation, insulation extending under the slab or insulation extending out from the building. Insulation extending away from the building shall be protected by pavement or by a minimum of 10 inches (254 mm) of soil. The top edge of the insulation installed between the exterior wall and the edge of the interior slab shall be permitted to be cut at a 45-degree (0.79 rad) angle away from the exterior wall. N1102.2.10 (R402.2.10) Crawl space walls. As an alternative to insulating floors over crawl spaces, crawl space walls shall be permitted to be insulated when the crawl space is not vented to the outside. Crawl space wall insulation shall be permanently fastened to the wall and extend downward from the floor to the finished grade level and then vertically and/or horizontally for at least an additional 24 inches (610 mm). Exposed earth in unvented crawl space foundations shall be covered with a continuous Class I vapor retarder in accordance with this code. All joints of the vapor retarder shall overlap by 6 inches (153 mm) and be sealed or taped. The edges of the vapor retarder shall extend at least 6 inches (153 mm) up the stem wall and shall be attached to the stem wall. N1102.2.11 (R402.2.11) Masonry veneer. Insulation shall not be required on the horizontal portion of the foundation that supports a masonry veneer. A section below thru the home shows the locations of all insulation/thermal envelope. On these sections, is shown the location of vapor barrier/vapor retarder. Eagle County lies in climate zone 6B. This is a prescriptive method for insulation and code compliance to energy efficient systems #1 Insulation values: show the chart that has the climate zone 6B. Fenestration U-Factor=.32 with a resolution 3.11 C revising the U-factor to .30 in Eagle Co. and .30 in Town of Vail Skylight U-Factor=.55 Ceiling R-Value = R49 Wood Framed Wall R-Value 20+5 or 13+10 (20 in the wall cavity and 5 continuous) Town of Vail, Avon, and Eagle have not adopted the R-5 continuous insulation requirement. Floor R-Value = R30 (or insulation to fill the framing cavity, r-19 min) Basement Wall R-Value =15/19 (R15 on the exterior or interior continuous OR R19 in the wall cavity) The r-19 shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous on the interior OR exterior of the foundation wall Slab R-Value =R10 for 4 feet from the edge of the slab measured horizontally or vertically For heated slabs, R-5 insulation shall be added to the slab edge Crawlspace wall R-Value = 15/19, which means R15 on the interior or exterior of the home or R-13 cavity insulation on the interior of the basement wall plus R-5 continuous on the interior OR exterior of the foundation wall #2 Fenestration and SHGCs (SHGCs are not required in this climate zone of 6) Fenestration U-Factor=.32 with a resolution 3.11 C revising the U-factor to .30 #3 Area weighted U-factor Calculations If some windows do not meet the U-factor .30 then an average of window areas can be calculated. #4 Mechanical system design criteria. 1. Minimum winter design temp of -20 degrees F. (resolution to section R303.9) 2. Heat loss calculations are required for all dwelling units (resolution to section R303.9) (Heat calcs, zones and layouts are due with the mech. permit application) 3. Minimum efficiency of main heat source is to be 92% 4. A whole house mechanical ventilation system (R303.4) is to be designed where the air infiltration rate of a dwelling unit is 5 air changes per hour or less where tested with a blower door at a pressure of 0.2 inch w.c (50 Pa) in accordance with Section N1102.4.1.2, the dwelling unit shall be provided with whole-house mechanical ventilation in accordance with Section M1507.3. 5. N1102.4.1.2 (R402.4.1.2) Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 3 air changes per hour in Zones 3 through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w.g. (50 Pascals). Where required by the building official, testing shall be conducted by an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the building official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. #5 Mechanical and service water heating system and equipment types, sizes and efficiencies. Note and locate water heater or side arm off boiler. Label efficiency of water heater and whether gas or electric is shown on plan set. #6 Equipment and system controls. Label location of thermostats and heating zones on key plans. Provide at least on programmable thermostat Initially programmed set point of heating no higher than 70 degrees and cooling no lower than 78 degrees #7 Duct sealing, duct insulation, and pipe insulation and locations. 1. Show locations of ductwork in area not in the heated envelope (shown on drawings for mech. permit) 2. All ducts to be sealed in accordance with the International Mechanical Code (M1601.4.1) 3. Ducts outside building envelope to be insulated with R-8, all other ducts with R-6 4. Building framing cavities shall not be used as supply ducts 5. Duct tightness test (section 403.2.2) Duct tightness test is not required if air handler and ducts are ALL located within conditioned space Duct tightness shall be verified by a) Post construction test Leakage to outdoors:<8 cfm/per 100 s.f. pf conditioned floor area or Total leakage:<12 cfm/ pre 100 b) Rough-in test Total leakage <6 cfm/per 100 s.f. of conditioned floor area test at a pressure differential of .1 in w.g. (25 Pa) across rough-in system #8 Air sealing details: General note: All exterior joints are to be caulked, gasketed, weather stripped, or otherwise sealed. Floor plates and sheathing joints are to be sealed. Refer to chart for locations and methods. 5/8" TYPE "X" GYPSUM WALL BOARD ON VAPOR RETARDER 5/8" TYPE "X" GYPSUM WALL BOARD ON VAPOR RETARDER HORIZONTAL 1X8 SHIP-LAPPED SIDING W/7" REVEAL -OR- VERTICAL 1X6 T&G (SQUARE EDGES) -OR- METAL PANELS REFER TO EXTERIOR ELEVATIONS FOR TYPE OF EXTERIOR CLADDING 6" NOMINAL TEXAS LIMESTONE VENEER ON DRAINAGE PLAIN SYSTEM WITH WEEPS AT BOTTOM OF THE WALL TYPICAL WOOD SIDING CLAD WALL TYPE TYPICAL WALL TYPE WITH STONE VENEER WALL SHEATHING WITH THERMAL AND AIR INFILTRATION BARRIER ON EXTERIOR FACE WALL SHEATHING WITH THERMAL AND AIR INFILTRATION BARRIER ON EXTERIOR FACE R-13 BATT INSULATION TO FILL REMAINDER OF 2X6 STUD WALL CAVITY. R-13 SRRAY 2" OF FOAM INSULATION ON INTERIOR FACE OF EXTERIOR WALL SHEATHINGTOTAL R-VAULE OF WALL = R-26 R-13 BATT INSULATION TO FILL REMAINDER OF 2X6 STUD WALL CAVITY. R-13 SRRAY 2" OF FOAM INSULATION ON INTERIOR FACE OF EXTERIOR WALL SHEATHING TOTAL R-VAULE OF WALL = R-26 WALL INSULATION: TYPICAL EXTERIOR WALL 2" SPRAY FOAM =R-13 3.5" BATT =R-13 TOTAL WALL CAVITY INSULATION =R-26 (R-20 MIN) (EXTERIOR CONTINUOUS INSULATION NOT REQUIRED - TOWN OF VAIL) TYPICAL FOUNDATION WALL AT LIVING SPACE 3.5" BLOWN-IN BATT (R-4.23 PER INCH). =R-13 1” RIGID INSULATION CONTINUOUS =R-4 2" DRAIN AND DRY ON EXT. OF FDN WALL = =R-10 TOTAL WALL R-VALUE =R-27 (R-19 MIN) TYPICAL SLAB EDGE/FROST WALL FOUNDATION WALL 2" DRAIN AND DRY ON EXT. OF FDN WALL = =R-10.00 (R-10 MIN) UNDER SLAB INSULATION: 2" RIGID INSULATION =R-10.00 (R-10 MIN) 3/4" SLAB EDGE INSULATION =R-7.00 (R-7 MIN) CANTILEVERED FLOOR INSULATION: 11 7/8" BLOWN-IN BATT (R-4.23 PER INCH) =R-50.23 (R-30 MIN) ROOF INSULATION: 12” SIP PANELS =+ R-49 (R-49 MIN) WINDOWS: FIXED =U-0.30 OPERABLE (AWNING AND CASEMENT) =U-0.30 PATIO DOOR AND SLIDING DOOR UNITS =U-0.30 INSULATION SUBCONTRACTOR MUST VERIFY THAT THE R-VALUES/U-VALUES OF PROPRIETARY PRODUCTS MEET OR EXCEEDS THE VALUES LISTED ABOVE AND THAT INSTALLATION PERFORMED IS PER MANUFACTURER'S SPECIFICATION. ALL WALL INSULATION SHALL COMPLETELY FILL STUD SPACES AND HAVE PROPER AIR-BARRIER SHEATHING ON BOTH SIDES OF THE STUD SPACES. INTERIOR WALLS ARE TO RECEIVE UNFACED SOUND ATTENUATION BATTS FOR ALL WALLS THAT DIVIDE HABITABLE ROOM (EXAMPLE: BEDROOM TO CLOSET WALL DOES NOT NEED SOUND INSULATION BEDROOM TO HALLWAY OR BEDROOM TO BEDROOM DOES) 2X6 = R-19 2X4 = R-13 PRESCRIPTIVE DESIGN INSULATION VALUE SUMMARY 2015 IECC (AND TOWN OF VAIL AMENDMENTS) 7 A0.1 RADON SYSTEM VENT STACK ROUGH RADON PIPING LAY OUT. RADON SYSTEM TO BE DESIGNED BY CERTIFIED SPECIALIST GRANULAR FILL - INCLUDE SOIL-GAS VENTILATION SYSTEM RADON SYSTEM VENT STACK GRANULAR FILL - INCLUDE SOIL-GAS VENTILATION SYSTEM B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. GARAGE LEVEL 8580' - 0" R-38 BIBS INSULATION AT BUILDING OVERHANGS (R-30 MIN.) DASH LINE INDICATES LOCATION OF VAPOR BARRIER/RETARDER IN ASSEMBLY ALUM CLAD WOOD WINDOWS U VALUE = .30 MAX. 12” SIP PANELS +R-49 ALSO ACTS AS AIR BARRIER AND VAPOR BARRIER R-13, R-19, OR R-30 UNFACED SOUND ATTENUATION BATTS AT INTERIOR WALLS / FLOORS, WHERE NEEDED FOR NOISE CONTROL. R-26 EXTERIOR WALL (TYP) SEE WALL DETAIL THIS SHEET CONC. SLAB (UNHEATED) R-30 AT GARAGE R-17 FURRING INSULATION (SEE FOUNDATION DETAIL R-10 SLAB EDGE INSULATION (SEE FOUNDATION DETAIL) R-10 RIGID INSULATION UNDER SLAB RADON SYSTEM IN GRAVEL UNDER SLAB R-10 DRAIN AND DRY INSULATION BELOW GRADE THE MECHANICAL SYSTEM FOR EACH SIDE OF THE DUPLEX WILL BE A "DESIGN-BUILD" TYPE SYSTEM. THE ARCHITECT HAS PROVIDED A PROPER SIZED MECHANICAL ROOM AND A VERTICAL CHASE TO THE HIGHEST FLOOR FOR THE NEEDS OF THE MECHANICAL SUB- CONTRACTOR. THE HEATING SYSTEM: THE HEATING SOURCE WILL BE A +92% HIGH- EFFICIENCY GAS-FIRED FURNACE WITH A WHOLE-HOUSE FORCED AIR SYSTEM DESIGNED IN ACCORDANCE WITH SECTION M1507 OF IBC2015 WITH AN ADDED AIR-CONDITIONING SYSTEM. THE FURNACE WILL BE A CLOSED LOOP SYSTEM WITH FRESH AIR TAKEN FROM THE EXTERIOR OF THE HOUSE. THE WATER HEATER WILL BE AN ELECTRIC OR GAS-FIRED HIGH- EFFICIENCY WATER STORAGE AND HEATING APPLIANCE. DRIVEWAY AND DECK RADIANT HEATING WILL BE ACCOMPLISHED WITH +92% EFFICIENCY CLOSED-SYSTEM BOILERS. A RADON MITIGATION SYSTEM WILL BE INSTALLED TO MEET IRC2015 CODE REQUIREMENTS. SEE SECTIONS THIS SHEET FOR A PROJECT SPECIFIC DIAGRAM. MECHANICAL AND RADON SYSTEMS 5/8" TYPE X GWB FOR 1-HR FIRE SEPARATION INSTALL 90 DEGREE FITTING AND 4 FT. TAIL OF 4 IN. DRAIN TILE EMBEDDED IN FREE DRAINING GRAVEL. NOTE: ALL CONTROL JOINTS, ISOLOATION JOINTS, CONSTRUCTION JOINTS AND ANY OTHER JOINTS IN THE CONCRETED SLABS, OR BETWEEN SLABS AND FOUNDATION WALLS SHALL BE SEALED WITH A CAULK OR SEALEANT. GAPS AND JOINTS SHALL BE CLEARED OF LOOSE MATERIAL AND FILLED WITH POLYUERETHANE CAULK OR OTHER ELASTOMERIC SEALANT APPLIED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ROUTE 4" ABS, PVC, OR EQUIVILENT GAS-TIGHT, SUBSLAB PASSIVE SLAB DEPRESSURIZATION VENT FROM BASEMENT TO ROOF THROUGH INTERIOR WALLS (SEE RADON PLANS). ALLOW FOR THE INSTALLATION OF AN IN-LINE FAN. PROVIDE A 110 VOLT RECEPTACLE AT THE FAN LOCATION . PLACE LABELS ON VENT AT EACH LEVEL: "RADON MITIGATION SYSTEM". EXTEND VENT PIPE 12" ABOVE ROOF.FANINSTALL RADON SENSOR AT LOWEST LEVEL IN-LINE FAN TO BE AT LOWEST LEVELMIN.1' - 0"970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:22:15 AMA0.1ENERGY SHEETJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date12" = 1'-0"1 ECO NOTES 1" = 1'-0"2 DETAIL - TYPICAL WALL 1/4" = 1'-0"3 INSULATION NOTES 1/8" = 1'-0" 5 5. RADON PLAN 1/8" = 1'-0"7 RADON/ENERGY SECTION 1/4" = 1'-0" 4 RADON SECTION 09/17/18 UP DN UP DN UP DN UP DN DN DN UP DN 669.5 SF B GARAGE 930.3 SF B LOWER 1635.7 SF A LOWERWINDOWWELLUNDER- BRIDGE DRIVEWAY ON- GRADE 1661.1 SF B MAIN 1640.3 SF A MAIN DECK DECK WINDOWWELLUNDER- BRIDGE DRIVEWAY ON- GRADE DECK 1115.1 SF B UPPER 794.1 SF A UPPER 617.7 SF A GARAGE LIVING ROOM BELOW LIVING ROOM BELOW KITCHEN BELOW DINING BELOW BRIDGE DRIVEWAY DRIVEWAY ON- GRADE 1686.7 SF B SITE COVERAGE 1675.3 SF A SITE COVERAGE 19.6 SF ROOF 1 3' - 8 3/4"3' - 11 1/2"4' - 0" 4' - 0" 2' - 0"4' - 0"4' - 0" HOUSE B - GRFA CALCULATIONS: BASEMENT PERCENTAGE CALCULATIONS: PERCENTAGE OF UNEXPOSED WALL SURFACE = 38% LOWER LEVEL GROSS AREA = 1,599.8 S.F. UNEXPOSED DEDUCTION (38%) = (- 607.9 S.F.) LOWER LEVEL SUB-TOTAL = 991.9 S.F. GARAGE EXEMPTION = (- 600 S.F.) LOWER LEVEL GRFA TOTAL = 391.9 S.F. MAIN LEVEL = 1,661.1S.F. UPPER LEVEL = 1,115.1 S.F. VAULTED +16' = 0 S.F. HOUSE B TOTAL GRFA = 3,168.1S.F. HOUSE A - GRFA CALCULATIONS: BASEMENT PERCENTAGE CALCULATIONS: PERCENTAGE OF UNEXPOSED WALL SURFACE = 38% LOWER LEVEL GROSS AREA = 1,635.7 S.F. UNEXPOSED DEDUCTION (38%) = (- 621.6 S.F.) LOWER LEVEL TOTAL = 1,014.1 S.F. MAIN LEVEL = 1,640.3 S.F. UPPER LEVEL = 1,411.8 S.F. GARAGE EXEMPTION = (- 600 S.F.) UPPER LEVEL GRFA TOTAL = 811.8 S.F. VAULTED +16' = 0 S.F. HOUSE A TOTAL GRFA = 3,466.2 S.F.970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:22:18 AMA0.2AREAS & HEIGHTSJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657SITE COVERAGE ALLOWED = 3,384.6 SF SITE COVERAGE PROPOSED = 3,381.6 SF GRFA TOTAL ALLOWED = 6,750.0 SF GRFA TOTAL PROPOSED = 6,634.3 SF 1/8" = 1'-0" 1 1. A LOWER LEVEL 1/8" = 1'-0"2 2. A MAIN LEVEL 1/8" = 1'-0"3 3. A UPPER LEVEL 1/8" = 1'-0"4 SITE COVERAGE Area Schedule (A GROSS) Name Area A GARAGE 617.7 SF A LOWER 1635.7 SF A MAIN 1640.3 SF A UPPER 794.1 SF Grand total: 4 4687.8 SF Area Schedule (A LIVING) Name Area A LOWER 1635.7 SF A MAIN 1640.3 SF A UPPER 794.1 SF Grand total: 3 4070.1 SF Area Schedule (B GROSS) Name Area B GARAGE 669.5 SF B LOWER 930.3 SF B MAIN 1661.1 SF B UPPER 1115.1 SF Grand total: 4 4376 SF Area Schedule (B LIVING) Name Area B LOWER 930.3 SF B MAIN 1661.1 SF B UPPER 1115.1 SF Grand total: 3 3706.5 SF Area Schedule (Gross Building) Name Area A GARAGE 617.7 SF A LOWER 1635.7 SF A MAIN 1640.3 SF A UPPER 794.1 SF B GARAGE 669.5 SF B LOWER 930.3 SF B MAIN 1661.1 SF B UPPER 1115.1 SF Grand total: 8 9063.8 SF Area Schedule (SITE COVERAGE) Name Area B SITE COVERAGE 1686.7 SF A SITE COVERAGE 1675.3 SF ROOF 1 19.6 SF Grand total: 3 3381.6 SF (115.7 SF UNUSED) HEIGHT STUDY 0 MODEL SHOWN WITHOUT HEIGHT CEILING HEIGHT STUDY 30 MODEL SHOWN WITH 30 FT. HEIGHT CEILING HEIGHT STUDY 33 MODEL SHOWN WITH 33 FT. HEIGHT CEILING SOME PORTIONS OF ROOF EXCEED 30 FT. NO ROOFS VISIBLE AT 33 FT. MAXIMUM ALLOWED 3,384.6 SF No. Description DateNOTE: SEE SITE PLAN FOR ACTUAL ROOF DATUM ELEVATIONS SHOWN OVER EXISTING AND NEW GRADES FOR ACCURATE HEIGHT CALCULATIONS. 09/17/18 BASEMENT WALL AREA = 388 SF UNEXPOSED WALL AREA = 82 SF B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" FINISH GRADE UNEXPOSED WALL AREA = 0 SF BASEMENT WALL AREA = 494 SF B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0"WALLS ARE AT AN ANGLE SEE A-ELEVATION NORTH BASEMENT WALL AREA = 145 SF UNEXPOSED WALL AREA = 145 SF B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" LINE OF EXTERIOR WALL BEYOND FINISH GRADE GRADES AT WINDOW WELL BASEMENT WALL AREA = 596 SF UNEXPOSED WALL AREA = 125 SF B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" BASEMENT WALL AREA = 275 SF UNEXPOSED WALL AREA = 25 SF 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" BASEMENT WALL AREA = 600 SF UNEXPOSED WALL AREA = 580 SF 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" BASEMENT WALL AREA = 275 SF UNEXPOSED WALL AREA = 190 SF 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" BASEMENT WALL = 224 SF UNEXPOSED WALL = 0 SF NOTE, THESE WALLS AT ANGLE SEE ELEVATION NORTH 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:22:21 AMA0.3BASEMENT DEDUCTIONJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 816571/8" = 1'-0" 1 B-ELEVATION - EAST - FOUNDATION 1/8" = 1'-0" 2 B-ELEVATION - NORTH - FOUNDATION 1/8" = 1'-0"3 B-ELEVATION - SOUTH - FOUNDATION 1/8" = 1'-0"4 B-ELEVATION - WEST - FOUNDATION 1/8" = 1'-0"5 A-ELEVATION - EAST - FOUNDATION1/8" = 1'-0"6 A-ELEVATION - SOUTH - FOUNDATION 1/8" = 1'-0"7 A-ELEVATION - WEST - FOUNDATION 1/8" = 1'-0" 8 A-ELEVATION -NORTH - FOUNDATION TOTAL BASEMENT WALL AREA = 2,997 SF TOTAL UNEXPOSED WALL AREA = 1,147 SF RATIO OF BASEMENT TO UNEXPOSED = 38.2%No. Description Date09/17/18 8574857685788578 8576 8580 8582 8584 8586 858 8 8590 859 2 85808584 85868588859085928600 8606 8604 859 4 8596 8598 8602 8604 8606 86078607 8606 86048602 86008594859685988582 8580 10 10 20 10 405 PH S WV WV 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 N 43° 45'36 " E - 162.37'N 89°04'35" E - 22.00'S 04° 20'18" E - 185.00'N 79° 09'51" W - 137.68' 78 79 80 02 00 8574857685788578 8576 8580 8582 858 4 8586 8588 8590 8592 85808584 85868588859085928600 8 6 06 8 6 0 4 8594 8596 8598 8602 8604 8606 0 7 8 6 0 786 06 8 604 860 2 86008594859685988582 8580 PH S WV WV GRAPHIC SCALE DN DN DN DN ADDRESS: 5128 GROUSE LANE EXISTING EDGE OF ASPHALT B LOWER LEVEL (BASEMENT) 8581'-0" (97'-0") B MAIN LEVEL 8592'-0" (108'-0") B UPPER LEVEL 8603'-0" (119'-0") A LOWER LEVEL (BASEMENT) 8584'-0" (100'-0") A MAIN LEVEL 8595'-0" (111'-0") A UPPER LEVEL 8606'-0" (122'-0) UNIT B - SECONDARY UNIT (WEST SIDE) HOUSE A - PRIMARY UNIT (EAST SIDE) SPECIAL INSPECTIONS NOTE: THE GENERAL CONTRACTORMUST SCHEDULE SPECIAL INSPECTIONS WITH THE GEOTECHNICAL ENGINEERAS DESCRIBED IN THE SOILS INVESTIGATION REPORT T.O.VAIL SITE PLAN NOTES: 1. NO RETAINING WALLS WITHIN 24" OF PROPERTY LINES. 2. 8% MAX SLOPE FROM EDGE OF ROADWAY FOR FIRST 10 FT. 3. ALL RETAINING WALLS OVER 4'-0" HEIGHT SHALL BE DESIGNED AND STAMPED BY A PROFESSIONAL ENGINEER. 5. UTILITY SCARS TO BE RE-GRADED TO NATURAL GRADE AND RE-SEEDED W/ NATURAL VEGETATION. 6. NO FINISH GRADES BETWEEN RETAINING WALLS TO EXCEED 2:1 SLOPE. LIMITS OF DISTURBANCE FENCE: USE EROSION CONTROL SILT FENCE ON DOWNHILL PORTION OF LOT 3' HEIGHT BOULDER RETAINING WALL B.O.W. = 8592'-0" T.O.W. = 8595'-0"8598'8596'8594' 8592' 8590' 8588' 8586' 8584' 8582'8600'8580' 20 ' - 0 " FRONT S ET BAC K 15' - 0"4' - 6"SIDEYARDSETBACK15' - 0"SIDEYARD SETBACK15' - 0" REAR YARD SETBACK9X19CAR9X18CAR9X18CAR9X19CAR 9X18 CAR 9X18 CAR8602'858 6' 858 8' 859 0 ' 859 2 ' 859 4 ' 859 6 '8584 ' 8617' - 6" 8615' - 9 1/4" 8618' - 11 1/4" 8624' - 1 1/4" 8620' - 1 7/8" 8614' - 9 7/8" 8612' - 9 1/4" 8611' - 9 3/8" 8609' - 5 1/4" ROOF EDGE ROOF EDGE ROOF EDGE ROOF EDGE ROOF EDGE ROOF EDGE ROOF EDGE ROOF EDGE ROOF EDGE 4' - 6"3' - 2" LOT SPLIT LINE (PROPOSED) EXISTING PARCEL B ACCESS EASEMENT ACCESS EASEMENT (SEE SURVEY) APPROXIMATE 100 YEAR FLOOD PLAIN PER F.E.M.A. STUDYDATED DEC. 4, 2007 HIGH WATER LINE OF CREEK EDGE OF GORE CREEK CENTERLINE OF GORE CREEK 50' - 0" STREAM SETBACKLINE 50' CREEK SETBACKLINE EXISTING ASPHALT ACCESS ROAD ABOVE - GRADE DECK (SHOWN HATCHED) ABOVE- GRADE DECK (SHOWN HATCHED) ON-GRADE FLAGSTONE PATIO BELOW ON-GRADE FLAGSTONE PATIO BELOW ASPHALT DRIVEWAY (HEATED) 850 SQ. FT. 78' 79' 80' 6.5% SLOPE5.5% SLOPE LOT SPLIT LINE (PARTY WALL) LOT SPLIT LINE (PROPOSED)DRIVEWAYBRIDGE: HEATED CONCRETE OVER STEEL STRUCTURE W/ STRUCTURAL GUARDRAIL AREA = 450 SF EXISTING DRIVEWAYEDGE TO BE REMOVED NEW DRIVEWAY EDGE W/ CONC. WALL & RAILING NEW & EXISTING DRIVEWAY EDGE EXISTING CONC. PAN TO REMAIN, MEETS TOWN OF VAIL REQ'S. ASPHALT DRIVEWAY (HEATED) AREA = 1,230 SF EXISTING FOUNDATION WALL TO BE REMOVED 8606.8' 8606' 8606' LOW-POINT FOR SURFACE DRAINAGE 8605.7' EXISTING WOOD STEPS EXISTING EDGE OF GROUSE LANE ASPHALT ADDRESS: 5130 GROUSE LANE ASPEN TREES TO REMAIN LARGE PINE TREES TO REMAIN SNOW STORAGE AREA = 250 SQ. FT. (+10% OF 1,680 SF DRIVEWAY AREA) SNOW STORAGE COMBINED AREA = 400 SQ. FT. (+30% OF DRIVEWAY AREA) EXISTING PINE TREE TO REMAIN 5' - 0"UTIL & DRAINAGE EASEMENT 5' - 0"UTUL & DRAINAGE EASEMENT1' - 6"ON-GRADE ENTRY FLAGSTONE PATIO 4' - 0" 4' - 0" WINDOW WELL BELOW BRIDGE 8615' - 4 1/2" 2' HEIGHT BOULDER RETAINING WALL B.O.W. = 8598'-0" T.O.W. = 8600'-0" 3' HEIGHT BOULDER RETAINING WALL B.O.W. = 8594'-0" T.O.W. = 8597'-0" 3' HEIGHT BOULDER RETAINING WALL B.O.W. = 8590'-0" T.O.W. = 8593'-0" LIMITS OF DISTURBANCE FENCE: 2" / 12"2" / 12"2" / 12"2" / 12"2" / 12"1 1/2" / 1 2 " 2" / 12 " 1 1/2" / 1 2 " METERCLOSET GAS METER METERCLOSET HOUSE AGAS METER 8618' - 11 1/4" ROOF EDGE 2' HEIGHT CONC. RETAINING WALL B.O.W. = 8604'-0" T.O.W. = 8606'-0" W/ STONE VENEER LIMITS OF DISTURBANCE FENCE: USE EROSION CONTROL SILT FENCE ON DOWNHILL PORTION OF LOT ADDRESS SIGN ON SPLIT BOULDER ADDRESS SIGN ON SPLIT BOULDER LOT 8 PARCEL A 9,360 SQ. FT. 5128 GROUSE LANE LOT 8 PARCEL B 7,563 SQ. FT. 5130 GROUSE LANE 3' HEIGHT BOULDER RETAINING WALL B.O.W. = 8596'-0" T.O.W. = 8599'-0" 3' HEIGHT BOULDER RETAINING WALL B.O.W. = 8600'-0" T.O.W. = 8603'-0" 3' HEIGHT BOULDER RETAINING WALL B.O.W. = 8600'-0" T.O.W. = 8603'-0"2' - 0"HIGH WATER LINE OF CREEK APPROXIMATE 100 YEAR FLOOD PLAIN PER F.E.M.A. STUDYDATED DEC. 4, 2007 TWO AIR- CONDITIONING CONDENSERS UNDER THE BRIDGE ON CONC PADS HOUSE AMETER CLOSET HEATED DRIVEWAYNOTE: HEATED DRIVEWAY WITHIN THE TOWN OF VAIL R.O.W. MUST BE ON A SEPERATE ZONE AND MARKED AT THE CONTROL BOX. CONTRACTOR NOTE: A REVOCABLE R.O.W. PERMIT IS REQUIRED FOR ALL IMPROVEMENTS WITHIN THE TOWN OF VAIL RIGHT-OF-WAY. LANDSCAPE AREA = 9,765 S.F. (-389 S.F.) (SHOWN SOLID GREEN HATCH) ASKING VARIANCE TO REMOVE ACCESS ROAD IN PARCEL A FROM COUNT = (1,000 S.F.) TO MEET REGULATION. TOTAL SITE AREA = 16,923 S.F. LANDSCAPE AREA MIN. (60%) = 10,153.8 S.F. 12-6C-10: LANDSCAPING AND SITE DEVELOPMENT:linklink At least sixty percent (60%) of each site shall be landscaped. The minimum ofany area qualifying as landscaping shall be ten feet (10') (width and length) with a minimum area not less than three hundred (300) square feet. (Ord. 19(1976) § 4: Ord. 8(1973) § 3.509) LANDSCAPING: Natural orsignificant rock outcroppings, native vegetation, planted areas and plant materials, including trees, shrubs, lawns, flowerbeds and ground cover, shall be deemed landscaping together with the core development such as walks, decks, patios, terraces, water features, and like features not occupying more than twenty percent (20%) ofthe landscaped area. WALKS & PATIOS AREAS = 900 S.F. (9%) (NOT TO EXCEED 20% OF LANDSCAPE AREA) HATCH SHOWS THE AREA REQUESTED BY VARIANCE TO BE REMOVED FROM THE LANDSCAPE AREA (60%) CALCULATIONS HATCHED AREA = 1,000 S.F.970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDate REVISIONS9/10/2018 10:36:53 AMA1.1SITE PLAN -OVERALLJG-1831 GROUSE DUPLEX PERMIT SET 8-28-189-10-18Jarenko5128 Grouse LaneVail, CO 816571/8" = 1'-0" 1 0. SITE PLAN No. Description DateGROUSE DUPLEX 5128 GROUSE LANE, VAIL, COLORADO 1/16" = 1'-0"2 Site Plan TRUE NORTH LIGHTING LEGEND COUNT: (5) WALL SCONCE LIGHT FIXTURES. HINKLEY "ARIA" 2304BK-LED OUTDOOR WALL LIGHT SIZE: 5.3" W x 18.5" H x 4.8" D 15 W LED 1100 LUMENS DARK SKY - YES EXTERIOR LIGHTS ALLOWED 1 PER 1,000 S.F. OF LOT AREA = 16 FIXTURES EXTERIOR LIGHTS PROPOSED = 16 FIXTURES LOT AREA (.3885 ACRES) = 16,923 S.F. RECESSED CAN CEILING LIGHT FOR EXTERIOR USE SELECTION BY OWNER/CONTRACTOR SIZE: TO BE DETERMINED COUNT: (11) RECESSED CAN LIGHT FIXTURES. SYMBOL A SYMBOL C SYMBOL B LED RECESSED WALL LIGHT OUTDOOR WATERPROOF 1P54 MODERN WALL LAMP - FOR EXTERIOR USE SIZE: 125mm W x 225 mm H x 85mm D COUNT: (3) NEAR GROUND, DOES NOT COUNT TOWARDS MAX. RECESSED CAN LIGHT FIXTURES. A A A A AA B B B B B B B B B C C C Aria is a contemporary style that effortlessly complements the facade of any exterior. Its modern shape in durable aluminum is enhanced by a stainless-steel mesh shade. Aria’s high style and low maintenance comes standard Dark Sky compliant. B B 09/17/18 8574857685788578 8576 8580 8582 858 4 8586 8588 8590 8592 85808584 85868588859085928600 8 6 06 8 60 4 8594 8596 8598 8602 8604 8606 8607860786068604860286008594859685988582 8580 10 10 20 405 P H S WV WV ( IN FEET ) GRAPHIC SCALE 0 EXISTING CONCRETE DRIVEWAY TO BE REMOVED, REGRADED, AND RE-BUILT IN SAME LOCATION. EXISTING ASPHALT OF GROUSE LANE EXISTING CONC. PAN TREES TO REMAIN (TYP) TREES TO REMOVE (TYP) REMOVE KEYSTONE BLOCK WALL NOTE: MUST RECEIVE PERMISSION FROM NEIGHBORS ON LOT 9 TO REMOVE PORTION OF WALL ON THEIRPROPERTY REMOVE CONC STOOP EXISTING HOUSE TO BE COMPLETELY DEMOLISHED EXISTING FOUNDATION WALL TO BE REMOVED EXISTING GABION ROCK RETAINING WALL TO BE REMOVED EXISTING DECK REMOVED PROPOSED BUILDING OUTLINE EXISTING ACCESS ROAD FOR ERW&SD ACCESS AND UTILITY EASEMENT TO LOT 8 PARCEL B ONLY. (SHOWN HATCHED) EFFECTIVE SEPTEMBER 30, 1999. BETWEEN EAGLE RIVER WATER AND SANITATION DISTRICT AND THE OWNERS OF LOT 3, LOT 4 & 5, LOT 7, LOT 8B LOT 8 PARCEL A 0.1748 ACRES 5128 GROUSE LANE LOT 8 PARCEL B 0.2137 ACRES 5130 GROUSE LANE INTERPOLATED CONTOURLINES FOR THE PURPOSES OF HEIGHT CALCULATIONS EXISTING WOOD STAIRS TO LOT 7 PROPERTY LOT LINE TO BE VACATED APPROXIMATE 20'-0" ROADWAYEASEMENT ON WEST SIDE OF HIGH WATER LINE OF CREEK APPROXIMATE CENTERLINE OF GORE CREEK EDGE OF CREEK HIGH WATER LINE OF CREEK APPROXIMATE 100 YEAR FLOOD PLAIN PER F.E.M.A STUDY DATED NOV. 2, 1982 APPROXIMATE 50 FT CENTERLINE OF CREEK SETBACK GORE CREEK BOULDERWALLS TO BE REMOVED FOOTPRINT AREA = 1,736 SQ. FT. AREA OF EXISTING ASPHALT ON PARCEL B = 1,500 SQ. FT. AREA OF EXISTING ASPHALT ON PARCEL A = 1,004 SQ. FT. CONC DRIVEWAY AREA = 206 SQ. FT.970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDateREVISIONS8/28/2018 11:22:34 AMA1.2SITE PLAN - DEMOJG-1831 GROUSE DUPLEX PERMIT SET 8-28-188-28-18Jarenko5128 Grouse LaneVail, CO 816571" = 10'-0"1 Site Plan - DEMO 12" = 1'-0"2 SATELLITE VIEW No. Description Date09/17/18 8574857685788578 8 576 8580 8582 858 4 85 86 858 8 8590 85 92 85808584 85868588859085928600 86 0 6 8 604 8594 859 6 859 8 8602 8604 8606 8607860786068604860286008594859685988582 8580 10 10 20 10 405 PH S WV WV 1 inch = ft. ( IN FEET ) GRAPHIC SCALE 0 ADDRESS: 5128 GROUSE LANE EXISTING EDGE OF ASPHALT LIMITS OF DISTURBANCE FENCE: USE EROSION CONTROL SILT FENCE ON DOWNHILL PORTION OF LOT 4' - 6"15' - 0" REAR YARD SETBACK4' - 6"3' - 2" LOT SPLIT LINE (PROPOSED) EDGE OF GORE CREEK CENTERLINE OF GORE CREEK 50' - 0" STREAM SETBACK LINE 50' CREEK SETBACK LINE EXISTING ASPHALT ACCESS ROAD ABOVE- GRADE DECK (SHOWN HATCHED) ABOVE- GRADE DECK (SHOWN HATCHED) ON-GRADE FLAGSTONE PATIO BELOW ON-GRADE FLAGSTONE PATIO BELOW ASPHALT DRIVEWAY (UNHEATED) 920 SQ. FT. LOT SPLIT LINE (PARTY WALL) LOT SPLIT LINE (PROPOSED) EXISTING CONC. PAN TO REMAIN, MEETS TOWN OF VAIL REQ'S. ASPHALT DRIVEWAY (UNHEATED) AREA = 1,230 SQ. FT. EXISTING WOOD STEPS EXISTING EDGE OF GROUSE LANE ASPHALT ASPEN TREES TO REMAIN LARGE PINE TREES TO REMAIN EXISTING PINE TREE TO REMAIN UTIL & DRAINAGE EASEMENT UTUL & DRAINAGE EASEMENT ON-GRADE ENTRY FLAGSTONE PATIO 4' - 0" LIMITS OF DISTURBANCE FENCE:2" / 12"1 1/2" / 1 2" 1 1/2" / 12" METER CLOSET GAS METER METER CLOSET GAS METER LIMITS OF DISTURBANCE FENCE: USE EROSION CONTROL SILT FENCE ON DOWNHILL PORTION OF LOT ADDRESS SIGN ON SPLIT BOULDER ADDRESS SIGN ON SPLIT BOULDER LANDSCAPE LEGEND SYMBOL NAME SIZE QUANTITY COLORADO BLUE SPRUCE (PICEA PUNGENS) 8' - 10' TALL 4A QUAKING ASPEN (POPULUS TREMULOIDES) 2" - 3" CAL. 15 B MOUNTAIN ASH (SORBUS AUCUPARIA) 8' TALL 2 C WESTERN SANDCHERRY (PRUNUS BESSEYI) 5 GALLON 5D VANHOUTTE SPIREA (SPIREA VANHOUTTE) 5 GALLON 5E LILAC FRAGRANT (SYRINGA VULGARIS) 5 GALLON 5F SNOWBERRY (SYMPHORICARPOS ALBUS) 5 GALLON 5G NATURAL GRASSES - ARKANSAS VALLEY SEED AREA = 2,800 S.F. LANDSCAPE NOTE: ALL DISTURBED AREAS SHALL RECIEVE REVEGETATION SEEDING WITH NATURAL GRASSES AND WILDFLOWER SEED MIX. IRRIGATION NOTE: ALL AREAS OF NEW SOD TO RECIEVE SPRAY IRRIGATION. ALL AREAS OF GROUND COVER AND TREE/SHRUB PLANGINGS TO RECEIVE UNDER-GROUND DRIP IRRIGATION. ALL IRRIGATION SYSTEMS TO BE DESIGNED BY A LANDSCAPE CONTRACTOR AND SUBMITTED TO THE ARCHITECT AND/OR OWNER FOR APPROVAL PRIOR TO INSTALLATION. RAIN SENSOR NOTE: THE IRRIGATION SYSTEM SHALL BE EQUIPPED WITH A RAIN SENSOR. EROSION CONTROL NOTE: ALL DISTURBED AREAS WITHOUT FORMAL LANDSCAPING TO RECIEVE REVEGETATION SEEDING. EROSION CONTROL SHALL BE MAINTAINED BY PLACEMENT OF HAY BAILS AND SILT FENCING ON DOWNSLOPE SIDE OF LOT AND IN DRAINAGE SWALES. A C B D E F G MULCHED BEDS W/ PRENNIALS & GROUND COVER AREA = 1,500 S.F. NOTE: AREA TO RECEIVE DRIP IRRIGATION (10% = 150 S.F.) NOTE:XERISCAPING - TEMPORARY IRRIGATION ONLY RESTORE NATURAL GRASSES RESTORE NATURAL GRASSES NATURAL GRASSES AT SNOW STORAGE AREAS C C B C C A A A A B C C C C C C C C C C C D D D D E E E E F F F F G G G G D E F G RESTORE TO NATURAL GRASSES NATURAL GRASSES THIS AREA TO REMAIN FULLY LANDSCAPED (SEE PHOTO) APPROXIMATE 100 YEAR FLOOD PLAIN PER F.E.M.A. STUDY DATED DEC. 4, 2007 HIGH WATER LINE OF CREEK 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:22:49 AMA1.3LANDSCAPE PLANJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/8" = 1'-0"1 LANDSCAPE PLAN 09/17/18 UP DN 4 A4.2 4 A4.2 A3.2 1 A3.1 2 A3.1 1 A3.3 1 A3.22 A3.3 2 A3.3 3 1 A4.2 1 A4.2 2 A4.1 2 A4.1 A3.3 4 1 A4.1 1 A4.1 3 A4.1 3 A4.1 DE CK ABO V E 33°57° W D 61' - 6"28' - 0"DECK ABOVE 15' - 0" 13' - 0"WINDOW WELL 8' - 0"HOT TUB EGRESSWALL OPTION 13' - 6 7/8" 23' - 4"3' - 0" 4' - 4" 4' - 4" 4 A4.1 4 A4.1 METER CLOSET GAS METER 17' - 1" 7' - 11" 15' - 5" 8' - 5 1/2" 12' - 7 1/2"7' - 0"1' - 0 1/2"5' - 0" 11 1/2"4' - 10 7/8" 6' - 4" 4' - 10" 2' - 6" 4' - 0" 18' - 6 7/8" 7' - 3" 5 1/2"2' - 5" 3' - 8" 3 1/2" 3' - 8" 9' - 0 1/2" 5 1/2"1' - 0" 5' - 0" 3' - 0" 4' - 0" 1' - 0"2' - 4 1/2" 8 3/4 " 6' - 0" 2' - 7" 2' - 6" 5 1/2 " DEN A02 BEDROOM 1 A03 CLOSET 1 A04 BATH 1 A05 BEDROOM 2 A06 CLOSET 2 A07 BATH 2 A08 BUNK ROOM A09 BATH 3 A10 LAUNDRY A12MECHANICAL A13 LOWER STAIR A01 3' - 4" 7' - 1 1/4" 12' - 2" 5 1/2" ELEV A00 2 A4.2 2 A4.2 5 1/2" 1' - 9" 4' - 7 1/2" 2' - 4 1/2" 11' - 9 1/4" 5 1/2"10" 13' - 0" 10"3' - 8"6' - 0" 1' - 9 1/2" 4' - 10 5/8"10' - 10 3/4" 8" 5' - 0" 10' - 9"2' - 0" 7' - 9 1/2" 6' - 4" 3' - 5 1/2" 1' - 2" 5' - 7" 8' - 6 1/4" 8' - 3 3/4" 14' - 3" 4' - 0"4' - 0" 4' - 6 3/4" 1' - 0 1/2"9' - 3 1/2" 10' - 3"3' - 0"13' - 1" 2' - 6"1' - 0" 09 10 A00 A06a A02 A12 A13 B05 A09 A03 A07 A04 A09 B09 B04 B07 07 08 05 02 03 01 B08 B01b B01c B06 A05 A10b A11 A06b A10a B01a B03a 06R @ 7 3/8"18 B00 R @ 7 3/8" 18ELEV B00 GARAGE B01 STAIR B02 ENTRY B03 LAUNDRY B004 MECH. B006 BEDROOM 1 B07 BATH 1 B09 CLOSET A11 WD 5' - 8 3/4"5 1/2" 4' - 6 1/2" 3' - 8 1/2" 5' - 6 3/4"1' - 2" 6' - 6 1/4" 7' - 8 3/4" 11 3/4" 6' - 0" 1' - 4" 1 1/2" 3' - 0" 9' - 0" 2' - 0" 1' - 6" 9' - 0" 3' - 6" 4' - 0" 5' - 6" 10' - 9"1' - 10"1' - 10" 3' - 7 1/2 "6' - 0"5 1/2"9' - 0 1/2" 4' - 0" 2' - 3 1/2" 5 1/2" 8' - 6 1/2" 1' - 2 1/2" BENCH EQ 6' - 0" EQ.1' - 2 1/2" 11' - 11" 5' - 10 1/2" 4' - 0" 13' - 0 3/4" 5' - 1 1/4" 4' - 0 1/4"1' - 9"2' - 0"3 A4.2 3 A4.2 2 A2.5 1 A4.6 3" 2 A4.6 3 A4.6 4 A4.6 5 A4.6 BOULDER RETAINING STONE PIER CL 1 B08 ENTRY CL B05 UP 7" 7" 58' - 7"B03b DECK ABOVE BLDG ABOVE R @ 6"2 8581' - 0" 8580' - 0" PILATSTER W/ STONE VENEER 9' - 9" 1' - 6" 3' - 9" 8' - 4"1' - 10"1' - 10" 3 A2.5 EGRESS LADDER R310.2.3 Window wells. The horizontal area of the window well shall be not less than 9 square feet, with a horizontal projection and width of not less than 36 inches. The area of the window well shall allow the emergency escape and rescue opening to be fully opened. Exception: The ladder or steps required by Section R310.2.3.1 shall be permitted to encroach not more than 6 inches into the required dimensions of the window well. R310.2.3.1 Ladder and steps. Window wells with a vertical depth greater than 44 inches shall be equipped with a permanently affixed ladder or steps usable with the window in the fully open position. Ladders or steps required by this section shall not be required to comply with Sections R311.7 and R311.8. Ladders or rungs shall have an inside width of not less than 12 inches, shall project not less than 3 inches from the wall and shall be spaced not more than 18 inches on center vertically for the full height of the window well. R310.2.3.2 Drainage. Window wells shall be designed for proper drainage by connecting to the building’s foundation drainage system required by Section R405.1 or by an approved alternative method. R310.2.4 Emergency escape and rescue openings under decks and porches. Emergency escape and rescue openings shall be permitted to be installed under decks and porches provided that the location of the deck allows the emergency escape and rescue openings to be fully opened and provides a path not less than 36 inches in height to a yard or court. WINDOW WELL - IRC-2015 REQ'S. SEE IRC2015 REQ'S. 1' - 6"5 A4.1 DUCT CHASE RADON PIPE, INCLUDE POWER FOR INLINE FAN 8' - 10 1/4" 2 A2.6 3 A2.6 DUCT CHASERADON PIPE, INCLUDE POWER FOR INLINE FAN MECH. AIR INTAKE & EXHAUST MECH. AIR INTAKE & EXHAUST DIM TO PARTYWALL CENTERLINELOT SPLIT LINE 32' - 0" SLOPE TO DRAIN 1/4" / FT SLOPE TO DRAIN 1/4" / FT 1 1/2" LOT SPLITLINE BEYONDA4.3 1 A4.4 1 5 1/2" 12' - 11 3/4" 5 1/2" 22' - 10 1/2"ON-GRADE CONC. PATIO 12' - 11 3/4" 2' - 5 1/4" BUNK CL. A14 4 A0.1 SEE ENERGY SHEET FOR MECH. AND RADON NOTES SEE ENERGY SHEET FOR MECH. AND RADON NOTES NOTE: A WALL WITHIN 36" OF THE LOT-SPLIT LINE MUST MAINTAIN 1-HR FIRE-SEPARATION. SEE PARTY WALL DETAILS FOR PROPER DETAILING OF 5/8" TYPE X GWB FROM FOUNDATION TO ROOF. NOTE: A WALL WITHIN 36" OF THE LOT-SPLIT LINE MUST MAINTAIN 1-HR FIRE-SEPARATION. SEE PARTY WALL DETAILS FOR PROPER DETAILING OF 5/8" TYPE X GWB FROM FOUNDATION TO ROOF.970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDate REVISIONS9/10/2018 10:36:57 AMA2.1FLOOR PLAN -LOWER LEVELJG-1831 GROUSE DUPLEX PERMIT SET 8-28-189-10-18Jarenko5128 Grouse LaneVail, CO 816571/4" = 1'-0"1 1. A LOWER LEVEL No. Description Date09/17/18 UP UP DN UP 4 A4.2 4 A4.2 A3.2 1 A3.1 2 A3.1 1 A3.3 1 A3.22 A3.3 2 A3.3 3 1 A4.2 1 A4.2 2 A4.1 2 A4.1 A3.3 4 1 A4.1 1 A4.1 3 A4.1 3 A4.114' - 1"DECK DECK BRIDGE DRIVEWAY (ABOVE) COVERED ENTRY 15' - 0" 61' - 6"10' - 0"28' - 0" 58' - 0"5' - 6 1/2" 15' - 1" 14' - 0"5 1/2"12' - 6 1/2"14' - 0" 4' - 0" 13' - 0"1' - 2 1/2" 9' - 5 1/2" 3 1/2"13' - 7" 14' - 0 1/2"3' - 8 1/2" 9' - 9 3/4" 13' - 1" 14' - 0" 32' - 0"MASTER DECKUP HOT TUB SHOWER14' - 1" 13' - 0"25' - 0"15' - 5" 21' - 1" 18' - 6 7/8" 4' - 0"11' - 0"2' - 0" 17' - 7" 12' - 6 1/2" 14' - 6 1/2" 11' - 4" 36' - 10 7/8" 18' - 6"1' - 1 1/2" 3' - 0" 5' - 0" 1' - 0 1/8"11' - 0" 3' - 0"4' - 0" 4 A4.1 8596' - 9" 8595' - 0" 4 A5.1 2 A4.2 2 A4.2 ELEV A20 DINING A22 GREAT ROOM A23 ENTRY CL A24 KITCHEN A25 PANTRY A26 POWDER A27 BEDROOM 3 (2ND MASTER) A28 BATH 4 A29 WC A30 W.I.C. A31 GREAT ROOM B22 KITCHEN B23 PANTRY B25 STAIR B21 ELEV. B20 DINING B24 MASTER BATHROOM B27 MASTER CLOSET B28 MASTER BATH B29 POWDER B26 ENTRY A21 A21 A20 A24 A27 A28A29 A30 B20 A26 2223 25 26 B26B27a B25 B27b R @ 7 3/8"15 27 B22 A23 14 13 11 15 24 20 12 B29 B30 B28 B24 30 28 29 33 3132 A22 A31b A31a A25 19 17 18 21 R @ 7"3 R @ 7 3/8"15 R @ 7 3/8"18 8' - 8" 3' - 6"WC B30 4' - 10 7/8" 6' - 4" 7' - 4" 2' - 6 1/4" 4' - 7" 7' - 1" 8 1/2"3' - 0" 4' - 0 1/2"13' - 1 3/8" 4' - 6 1/2" 19' - 3"3' - 8 1/2" 5' - 8 3/4" 2' - 2 3/4" 4' - 4" 15' - 1" 2' - 0 3/4"5 1/2"16' - 9 1/2" 4' - 6 1/2" 3' - 8 1/2" 5' - 6 3/4" 3' - 8 1/2" 3' - 6" 4' - 7 3/4" 1' - 9"5 1/2"6' - 5" 3' - 10 1/2" 5 1/2" 3' - 8 1/2"9 1/2 " 5' - 0" 3' - 0" 5' - 2 1/2" 1' - 0 1/2" 12' - 0" 11 1/2" GAS FIREPLACE8' - 1 1/2" 3' - 2 1/2" 1' - 9" 12' - 4" 13' - 0" 5 1/2"2' - 0" 4' - 0" 5"5' - 10 1/2"3' - 0" 5' - 0" 1' - 1 1/2"2' - 6" 3' - 0 1/2" 11' - 11" 3' - 7 1/2"5' - 0" 6 3/4"6' - 4"3' - 5 1/2" 6' - 4"10 1/2"2' - 0" 4' - 0" 11"6 3/4"11' - 10 7/8"10 1/4"6' - 4 3/4" 3 1/2"3' - 11 1/2" 13' - 3 1/2" 1' - 2 1/2"5 1/2" 3' - 10 1/2" 7' - 11 1/2" 5 1/2" 6' - 3" 4' - 0" 2' - 0" 3' - 8 1/2" 5 1/2" 4' - 7 3/4" 5 1/2" 6' - 1 3/4" 2' - 9" 2' - 3 3/4" 11' - 6 3/4" 5 1/2" OPEN TO LEDGE BELOW FIREPLACE 3 A4.2 3 A4.2 2 A2.5 1 A4.6 2 A4.6 3 A4.6 4 A4.6 5 A4.6 3 A2.5 5 A4.1 WINDOW WELL EGRESS LADDER SEE IRC2015 REQ'S. 2 A2.6 3 A2.6 RADON PIPE MECH. CHASE RADON PIPE MECH. CHASE A4.3 2 A4.4 2 A4.5 1 A4.5 2 1' - 0"HANDRAIL ATTACHED TO WALL 3' - 6" 1' - 9 1/2" 4 A0.1 NOTE: A WALL WITHIN 36" OF THE LOT-SPLIT LINE MUST MAINTAIN 1-HR FIRE-SEPARATION. SEE PARTY WALL DETAILS FOR PROPER DETAILING OF 5/8" TYPE X GWB FROM FOUNDATION TO ROOF. NOTE: A WALL WITHIN 36" OF THE LOT-SPLIT LINE MUST MAINTAIN 1-HR FIRE-SEPARATION. SEE PARTY WALL DETAILS FOR PROPER DETAILING OF 5/8" TYPE X GWB FROM FOUNDATION TO ROOF.970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS9/10/2018 10:37:03 AMA2.2FLOOR PLAN -MAIN LEVELJG-1831 GROUSE DUPLEX PERMIT SET 8-28-189-10-18Jarenko5128 Grouse LaneVail, CO 816571/4" = 1'-0"1 2. A MAIN LEVEL No. Description Date09/17/18 DN DN DN 4 A4.2 4 A4.2 A3.2 1 A3.1 2 A3.1 1 A3.3 1 A3.22 A3.3 2 A3.3 3 1 A4.2 1 A4.2 2 A4.1 2 A4.1 A3.3 4 1 A4.1 1 A4.1 8607' - 0" 3 A4.1 3 A4.1 33°57° VA U LTED BE L O W BRIDGE DRIVEWAY NEW DRIVEWAY DOWN TO ENTRY 12' - 8 1/2" VAULTED TO BELOW 5 1/2" 14' - 7"14' - 1"24' - 1" 22' - 1"11' - 6 3/4" 9' - 10 3/4"11' - 2"25' - 1"3' - 6"10' - 7"58' - 0"11' - 7"WALL OPTION 13' - 0" 12' - 6 1/2" 25' - 0" 8' - 9 3/4"27' - 8 1/4" 61' - 6"15' - 1" 23' - 4" 5' - 11" 13' - 8"4' - 0" 14' - 0" 14' - 0" 32' - 0"2' - 0"2' - 0" 26' - 0"13' - 0"15' - 0" 28' - 0"17' - 6" 3' - 0" 5' - 0" 1' - 0" 4 A4.1 4 A4.1 METER CLOSET 2 A4.2 GARAGE A39 ELEV A34 MUD ROOM / OWNER ENTRY A32 STAIR A33 MASTER BEDROOM A38 MASTER CLOSET A35 MASTER BATH A36 WC A37 BEDROOM 3 B33 ELEV. B31 DEN B32 BATH 2 B39 STAIR B42 2' - 5 3/4"2' - 0 1/2"5' - 0" 3' - 0" 2' - 0" 1' - 8" 5' - 0"3' - 0" 1' - 7 1/2"2' - 8" 5' - 0" 7' - 3 1/2" 2' - 9"CL B41 CLOSET 2 B43 A32 A34 A39a A38 A36 A35 B31 40 R @ 7 3/8"15 A39b 50 52 57 56 34 35 36 55 54 B40 B39a B39b 51 53 39 A37 42 41 3837 47 49 48 44 45 B33 B41 B37 4346 R @ 7 3/8"15 4' - 0"3' - 5" 6' - 2" 1' - 0" 3' - 6" 5 1/2" 6' - 3 1/2" 10' - 3" 14' - 2 1/4" 5 5/8" 2' - 0" 3' - 8 1/2" 5' - 6 3/4" 3' - 6 1/4" 5' - 9" 5 1/2" 5 1/2" 7' - 0" 3' - 7" 3' - 5 1/2" 4' - 1 1/2" 3 1/2" 8' - 7 1/2"5 1/2"1' - 0"3' - 0" 6' - 0" 5' - 0" 9' - 7 1/4" 7' - 9 1/2" 6' - 2 1/2" 5' - 4 1/4" 4' - 9 1/4" 5' - 2 3/4" 3' - 0 1/4" 3' - 0" 5' - 0" 1' - 7 1/2" 1' - 11" 10' - 9" 2' - 4 1/2" 5' - 7 1/2" 3 A4.2 3 A4.2 2 A2.5 1 A4.6 2 A4.6 3 A4.6 4 A4.6 5 A4.6 3 A2.5 5 A4.1 GAS METER 2 A2.6 3 A2.6 RADON PIPE RADON PIPE A4.3 3 A4.4 3 3' - 0"2" / 12" DRAINAGE CRICKET HIGH WINDOWS 4 A0.1 NOTE: A WALL WITHIN 36" OF THE LOT-SPLIT LINE MUST MAINTAIN 1-HR FIRE-SEPARATION. SEE PARTY WALL DETAILS FOR PROPER DETAILING OF 5/8" TYPE X GWB FROM FOUNDATION TO ROOF. NOTE: A WALL WITHIN 36" OF THE LOT-SPLIT LINE MUST MAINTAIN 1-HR FIRE-SEPARATION. SEE PARTY WALL DETAILS FOR PROPER DETAILING OF 5/8" TYPE X GWB FROM FOUNDATION TO ROOF.970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS9/10/2018 10:37:06 AMA2.3FLOOR PLAN -UPPER LEVELJG-1831 GROUSE DUPLEXPERMIT SET 8-28-189-10-18 Jarenko5128 Grouse LaneVail, CO 816571/4" = 1'-0"1 3. A UPPER LEVEL No. Description Date09/17/18 79 00 8580 8582 8584 8586 8588 8580 DN 4 A4.2 4 A4.2 A3.2 1 A3.1 2 A3.1 1 A3.3 1 A3.22 A3.3 2 A3.3 3 1 A4.2 1 A4.2 2 A4.1 2 A4.1 A3.3 4 1 A4.1 1 A4.1 3 A4.1 3 A4.1 4 A4.1 4 A4.1 7 A0.1 4 A5.1 2" / 12"2" / 12"2" / 12" 2" / 12"2" / 12"2" / 12" 1 1/2" / 12" 1 1/2" / 12" 1 1/2" / 12"2' - 0"4' - 0"4' - 0" 2' - 0" 2' - 0" 4' - 0"4' - 0"2' - 0"2' - 0" 2' - 0"2' - 0" 4' - 0"4' - 0"2' - 0"4' - 0"2' - 0"8624' - 1 1/4" 8618' - 11 1/4" 8612' - 6 3/8" 8620' - 1 7/8" 8612' - 9 1/4" 8611' - 9 3/8" 8609' - 5 1/2" 2 A4.2 2 A4.2 3 A4.2 3 A4.2 2 A2.5 1 A4.6 2 A4.6 3 A4.6 4 A4.6 5 A4.6 3 A2.5 5 A4.1 2 A2.6 3 A2.6 RADON AND MECH. AIR INTAKE/EXHAUST RADON AND MECH. AIR INTAKE/EXHAUST 1' - 7 1/4"4' - 0"2' - 0"2' - 0" 20' - 0" 20' - 0"20' - 0" 20' - 0"DRAINAGE CRICKET BELOW DRAINAGE CRICKET DRAINAGE CRICKET SHORT SNOW GUARD ABOVE VENTS SNOW RETENTION DEVICE: SEE PROPRIETARY PRODUCT INFORMATION THIS SHEET (SHOWN TYP) OVERHANG NOTE: THE OVERHANG DIMENSION TYPICALLY SHOWN IS A DIMENSION FROM THE EXTERIOR EDGE OF THE STUD FRAMING (PRIOR TO SHEATHING) TO THE EDGE OF THE ROOF SLAB. THE DOUBLE FASCIA IS NOT INCLUDED IN THE DIMENSION. ROOF OVERHANG AT LOT SPLIT LINE: THE ROOF MAY OVERHANG THE LOT-SPLIT LINE BY TOWN OF VAIL CODE AMENDMENT. IT IS RECOMMENDED THAT WORDING REGARDING THE OVERHANG IS WRITTEN INTO THE DUPLEX NEIGHBOR PARTY-WALL AGREEMENT. LOT-SPLIT LINE GUTTER & DOWNSPOUT: INCLUDE POWER FOR SNOW-MELT WIRING. RUN SNOW MELT DOWN DOWNSPOUT. RUN DOWNSPOUT UNDER-GROUND TO DAYLIGHT. 4 A0.1 SNOW RETENTION NOTES: PROPRIETARY PRODUCT "ROCKY MOUNTAIN SNOW GUARDS INC." BLIZZARD II SNOW FENCE SYSTEM. THIS SYSTEM ASSUMES 24 GUAGE, 16" NEW TECH MACHINERY SS150 DOUBLE FOLD PANEL STANDING SEAM METAL ROOF. BASED ON CALCULATIONS OF 145# SNOW LOAD, BRACKETS TO BE SPACED 16" (EVERY SEAM). THE EAVE ROW SHOULD BE PLACED 18" ABOVE THE EAVE EDGE AND SUPPLEMENTAL ROWS SHOULD NOT HAVE MORE THAN 21 FEET BETWEEN THEM. THE GENERAL CONTRACTOR MUST NOTIFY ARCHITECT AND ROCKY MOUNTAIN SNOW GUARDS WITH ANY DEVIATIONS FROM THIS ROOF PLAN DRAWING. CONTRACTOR TO ORDER SNOW MITIGATION PARTS WITH POWDER COATING TO MATCH ROOF PANELS AND TO ACHIEVE LONGEVITY.970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:02 AMA2.4ROOF PLANJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 816571/4" = 1'-0"1 4. ROOF LEVEL No. Description Date1/4" = 1'-0"2 SNOW RETENTION 09/17/18 79 80 00 8580 8582 8584 8586 8588 860 6 4 A4.2 4 A4.2 1 A4.2 1 A4.2 2 A4.1 2 A4.1 1 A4.1 1 A4.1 3 A4.1 3 A4.1 4 A4.1 7 A0.1 2 A4.2 2 A4.2 3 A4.2 3 A4.2 2 A2.5 1 A4.6 2 A4.6 3 A4.6 4 A4.6 5 A4.6 3 A2.5 5 A4.1 8607' - 0" 8607' - 0" 8606' - 6" 8606' - 6" 8600' - 0" 8600' - 0" LOWER TOP AS NEEDED LOWER TOP AS NEEDED LOWER TOP AS NEEDED LOWER TOP AS NEEDED LOWER TOP AS NEEDED LOWER TOP AS NEEDED 8606' - 0"8597' - 0" 8597' - 0" 8597' - 0" 8597' - 0" 8593' - 9 3/4" 8589' - 0" 8584' - 0" 8584' - 0" 8584' - 0" 8584' - 0" 8584' - 0" 8605' - 7" 8605' - 10" 8605' - 8" 8587' - 0" 8596' - 0" 8595' - 6" 8594' - 6" 8584' - 0" 8584' - 0" 8584' - 0" 8581' - 0" 8581' - 0" 8587' - 0" 8596' - 0"8591' - 10 1/2" 8596' - 0 3/4" 8590' - 11 1/4" 8584' - 0" 8581' - 0" 8581' - 0" 8581' - 0" 8581' - 0" 8581' - 0" 8581' - 0" 8581' - 0" 8584' - 0" 8584' - 0" 8580' - 6" 8580' - 0" 8580' - 0" 8580' - 0" 8581' - 0" 8581' - 0" 8581' - 0" 8580' - 0" 8580' - 10" 8583' - 8" 8596' - 8" ARCHITECTURAL FOUNDATION PLAN: THIS PLAN IS A PRELIMINARY REPRESENTATION OF WALL HEIGHTS AS DEPICTED IN THE 3D BIM REVIT MODEL. THE STRUCTURAL ENGINEER MAY CHANGE THE HEIGHTS AS NEEDED. REFER TO THE STRUCTURAL FOUNDATION PLAN FOR FINAL CONSTRUCTION DOCUMENTS. NOT FOR CONSTRUCTION 8583' - 8" 8583' - 8" 8580' - 0" 8584' - 0" 2 A2.617' - 6"19' - 6" 3 A2.6 15' - 6"5' - 1 3/4"5' - 0 3/4" 4' - 2" 4' - 7 3/4" 6' - 7 1/4" 4' - 7" 5' - 1 3/4" 4' - 7 3/4" 4' - 7 1/2"4 A0.1 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 1 A4.1 B LOWER LEVEL 8581' -0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" 1:1 EXCAVATION SLOPE REMOVE EXISTING WALL REMOVE EXISTING SLAB PROPERTY LINE 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" B LOWER LEVEL 8581' -0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" 1:1 EXCAVATION SLOPE REMOVE EXISTING WALL REMOVE EXISTING SLAB PROPERTY LINE 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDate REVISIONS8/28/2018 11:23:03 AMA2.5FOUNDATION PLANJG-1831 GROUSE DUPLEX PERMIT SET 8-28-188-28-18Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/4" = 1'-0"1 FOUNDATION PLAN 1/4" = 1'-0"2 FOUNDATION SECTION 1 1/4" = 1'-0"3 FOUNDATION SECTION 2 09/17/18 4" CONC. SLABAREA = 1,544 SFVOLUME = 19 CY 4" CONC. SLABAREA = 876 SFVOLUME = 10.8 CY 4" CONC. SLABAREA = 630 SFVOLUME = 7.8 CY 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 1 A4.1 B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" 1:1 EXCAVATION SLOPE PROPERTY LINE 1' - 9"2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 1 A4.1 B LOWER LEVEL 8581' -0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" 1:1 EXCAVATION SLOPE PROPERTY LINE 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" 5 A4.1 REMOVE EXISTING SLAB WALL TO REMAIN DURING EXCAVATION REMOVE TOP OF WALL 1:1 SLOPE EXCAVATION 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:04 AMA2.6FOUNDATION 3DJG-1831 GROUSE DUPLEX PERMIT SET 8-28-188-28-18Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1 3D FOUNDATION 1/4" = 1'-0"2 FOUNDATION SECTION 3 1/4" = 1'-0"3 FOUNDATION SECTION 4 1/4" = 1'-0" 4 FOUNDATION SECTION 5 Foundation Wall Schedule Wall Type Length Width Volume Foundation Walls 16' - 8 1/4" 8" 3.3 CY Foundation Walls 14' - 10" 8" 3.91 CY Foundation Walls 16' - 0 1/8" 8" 5.03 CY Foundation Walls 14' - 4 5/8" 11 1/4" 5.4 CY Foundation Walls 15' - 9 3/4" 10" 5.51 CY Foundation Walls 8' - 10 1/4" 1' - 2" 5.87 CY Foundation Walls 15' - 10" 10" 6.69 CY Foundation Walls 22' - 5 3/4" 8" 7.26 CY Foundation Walls 14' - 6 1/8" 10" 9.02 CY Foundation Walls 24' - 2" 10" 9.77 CY Foundation Walls 31' - 3 5/8" 10" 9.83 CY Foundation Walls 30' - 6 1/8" 10" 10.02 CY : 54 579' - 2 7/8" 114.61 CY Foundation Wall Schedule Wall Type Length Width Volume Foundation Walls 9" 8" 0.07 CY Foundation Walls 3' - 0" 8" 0.11 CY Foundation Walls 1' - 9" 8" 0.28 CY Foundation Walls 10' - 7 1/2" 8" 0.31 CY Foundation Walls 10' - 7 1/2" 8" 0.35 CY Foundation Walls 11' - 7 1/2" 8" 0.38 CY Foundation Walls 2' - 0" 8" 0.2 CY Foundation Walls 12' - 7 1/2" 8" 0.63 CY Foundation Walls 20' - 5 7/8" 1' - 2" 0.3 CY Foundation Walls 16' - 4 1/2" 8" 0.72 CY Foundation Walls 4' - 0" 8" 0.4 CY Foundation Walls 5' - 4 1/8" 8" 0.43 CY Foundation Walls 5' - 8" 8" 0.49 CY Foundation Walls 14' - 11 1/2" 8" 0.53 CY Foundation Walls 12' - 3" 8" 1.23 CY Foundation Walls 7' - 4" 8" 0.72 CY Foundation Walls 20' - 0 3/8" 1.54 CY Foundation Walls 8' - 0" 8" 0.93 CY Foundation Walls 12' - 5" 8" 1.02 CY Foundation Walls 2' - 5" 10" 1.17 CY Foundation Walls 13' - 0" 8" 1.24 CY Foundation Walls 13' - 4" 8" 1.25 CY Foundation Walls 6' - 0 3/8" 1' - 2" 1.29 CY Foundation Walls 14' - 0" 8" 1.33 CY Foundation Walls 21' - 4" 1' - 2" 1.34 CY Foundation Walls 21' - 1 1/4" 7" 1.37 CY Foundation Walls 7' - 11 5/8" 8" 1.39 CY Foundation Walls 14' - 10 3/8" 8" 1.51 CY Foundation Walls 4' - 2 5/8" 10" 1.52 CY Foundation Walls 6' - 2" 10" 1.79 CY Foundation Walls 24' - 9 7/8" 10" 2.3 CY Foundation Walls 19' - 4 3/4" 8" 2.39 CY Foundation Walls 5' - 4" 1' - 2" 2.46 CY Footing Schedule Foundation Thickness Area Volume 8" 16.9 SF 0.42 CY 8" 4 SF 0.1 CY 8" 18.6 SF 0.46 CY 8" 30.4 SF 0.75 CY 10" 23.7 SF 0.73 CY 10" 9.6 SF 0.3 CY 10" 25 SF 0.77 CY 10" 14.7 SF 0.45 CY 10" 8.3 SF 0.26 CY 10" 32.3 SF 1 CY 10" 14.7 SF 0.45 CY 10" 24.4 SF 0.75 CY 10" 4.7 SF 0.15 CY 10" 51.8 SF 1.6 CY 10" 9.9 SF 0.31 CY 10" 26.4 SF 0.81 CY 10" 25.3 SF 0.78 CY 10" 22.2 SF 0.69 CY 10" 3.3 SF 0.1 CY 10" 12.2 SF 0.38 CY 10" 1.3 SF 0.04 CY 10" 9.4 SF 0.29 CY 10" 1.3 SF 0.04 CY 10" 10.1 SF 0.31 CY 10" 6.7 SF 0.21 CY 10" 9.6 SF 0.3 CY 10" 14.2 SF 0.44 CY 10" 31.1 SF 0.96 CY 10" 5.4 SF 0.17 CY 10" 37.5 SF 1.16 CY 10" 23.9 SF 0.74 CY 10" 36.6 SF 1.13 CY 10" 42 SF 1.26 CY 10" 12.3 SF 0.3 CY 10" 27.8 SF 0.86 CY 10" 19.4 SF 0.6 CY 10" 15.4 SF 0.47 CY 10" 22.8 SF 0.71 CY 1' - 0" 74.5 SF 2.76 CY 1' - 0" 18.5 SF 0.69 CY Grand total: 40 24.66 CY TOTAL ESTIMATED VOLUME OF CONCRETE = 176.8 CUBIC YARDS DISCLAIMER: THE AMOUNT REPRESENTED IS ONLY AS ACCURATE AS THE BUILT REVIT BIM MODEL. THE NUMBER CAN BE USED AS AN ESTIMATE FOR MATERIAL TAKE-OFFS. IT IS STILL THE GENERAL CONTRACTOR'S RESPONSIBILITY TO PROVIDE ACCURATE MATERIAL ESTIMATES. NOTE: EXCLUDES SLAB IN HOUSE A GARAGE UPPER LEVEL AND DRIVEWAY BRIDGE. EXCLUDES STANDALONE PADS AND THICKENED FOOTINGS. EXCLUDES WALKS AND PATIOS 09/17/18 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 4 A4.2 B LOWER LEVEL 8581' -0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" 7 A0.1 WOOD SIDING ON GARAGE DOORS EXPOSED STEEL BEAMS & POSTS STONE VENEER WALL STEEL BEAM HEADER METAL PANEL WALL STONE VENEER COLUMN BASE W/ CUT-STONE CAP METAL WINDOW TRIM EXPOSED STEEL BEAMS & POSTS 3' - 8"HORIZ. SHIPLAP WOOD SIDING VERT. SHIPLAP WOOD SIDING HORIZ. SHIPLAP WOOD SIDING HORIZ. SHIPLAP WOOD SIDING STANDING SEAM METAL ROOF METAL PANEL WALL METAL PANEL WALL VERTICAL SHIPLAP WOOD SIDING 8620' - 1 7/8" 8614' - 9 5/8" 8612' - 9" 8611' - 9 1/8" 8609' - 5 1/2" 8603' - 9" 8603' - 9" 4 A5.1 NOTE: SEE STRAIGHT-ON ELEVATIONS FOR NOTES AND DETAILS A02 40 50 3435 36 51 B22 A23 05 02 03 01 39 42 41 38 37 13 11 15 12 B01b B01c A22 A25 19 17 18 5' - 10"3' - 10"12' - 0" 4' - 0"4' - 0" 4' - 0" 4 A4.6 5 A4.6 A5.2 7 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 4 A4.2 B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" 7 A0.1 HORIZ. SHIPLAP WOOD SIDING 8620' - 1 7/8" 8614' - 9 3/4"5' - 10"MAX.ENGINEERED GUARDRAIL STONE VENEER STONE VENEER WALL 1 1/2" 12" EXPOSED STEEL BEAM 7' - 1 1/8"NOTE: SEE STRAIGHT-ON ELEVATIONS FOR NOTES AND DETAILS 43 58 20 21 44 59 60 45 46 61 A21 49 48 47 62 A39a 4 A4.6 5 A4.6 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject numberDate REVISIONS8/28/2018 11:23:11 AMA3.1ELEVATIONSJG-1831 GROUSE DUPLEX PERMIT SET 8-28-188-28-18Jarenko5128 Grouse LaneVail, CO 816571/4" = 1'-0"2 B-ELEVATION - NORTH 1/4" = 1'-0"1 B-ELEVATION - SOUTH No. Description Date1 Revision 1 Date 109/17/18 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 1 A4.2 B LOWER LEVEL 8581' -0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0"3' - 6"8584' - 9"31' - 6"2" 12" 8609' - 5 1/2" 8611' - 9 1/8" 8612' - 9" 8624' - 1 1/4" 8620' - 1 7/8" 8614' - 9 5/8" FIREPLACE DIRECT VENT THRU WALL METER CLOSET METAL PANEL WALL METAL PANEL WALL METAL PANEL WALL STONE VENEER CHIMNEY METER CLOSET DOORS CUSTOM ENTRY DOOR TO BE DETERMINED VERT. SHIPLAP WOOD SIDING HORIZ. SHIPLAP WOOD WALL ABOVE GRADE DECK EXPOSED STEEL BEAMS & POSTS METAL WINDOW TRIM HOT TUB LOCATION WELDED METAL RAILING W/ WOOD CAP EXPOSED STEEL BEAMS & POSTS 2 A4.2 62 26 25 27 B27b 50 29 28 30 32 31 33 10 09 B03aB01a 57 56 55 6' - 0"8' - 0" 8" 2' - 6" 2' - 10"2' - 0"4' - 0" A39b 54 51 3 A4.2 2 A4.6 3 A4.6 A5.2 6 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 2 A4.1 1 A4.1 B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" 8618' - 11 1/4" 8615' - 9" 8609' - 4" HORIZ. SHIPLAP WOOD SIDING W/ STAIN 2X6 WOOD CORNER TRIM 2X4 WOOD WINDOW FRAME METAL CLAD WOOD WINDOWS STANDING SEAM METAL ROOF STONE VENEER VERTICAL SHIPLAP WOOD SIDING METAL PANEL WALL STEEL POSTS & BEAMS HOT TUB LOCATION WELDED METAL RAILINGS W/ WOOD CAP EXPOSED STEEL BEAM METAL PANEL WALL VERTICAL SHIPLAP WOOD SIDING METAL WINDOW TRIM EXPOSED STEEL BEAM & POST STEEL BEAM HEADER IN STONE VENEER 2" 12" NOTE: SEE STRAIGHT-ON ELEVATIONS FOR NOTES AND DETAILS13 11 12 14 36 15 A02 0203 A234' - 0"8" 8' - 0" 4' - 0" 4' - 0" 4' - 0" 42 41 18 17 19 05 06 A5.2 4 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:18 AMA3.2ELEVATIONSJG-1831 GROUSE DUPLEX PERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 816571/4" = 1'-0"1 B-ELEVATION - WEST 1/4" = 1'-0"2 A-ELEVATION - EAST No. Description Date1 Revision 1 Date 109/17/18 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 3 A4.1 4 A4.1 8618' - 11 1/4" 8624' - 1 1/4" 8596' - 9" VERTICAL SHIPLAP WOOD SIDING METAL PANEL WALL W/ METAL WINDOW TRIM HORIZ. SHIPLAP WOOD SIDING WALL R @ 7 3/8"15 METAL HANDRAIL STONE VENEER W/ CUT-STONE CAP 2" 12" METAL PANEL SIDING GAS METER NON-OPERABLE WINDOWS IN STAIRWELL 43 58 20 21 44 59 45 60 61 46 23 24 22 48 49 47 A21 8' - 0"7' - 0"5' - 0"2' - 0" 1' - 0" 5' - 0" 4' - 0" 7' - 0"5' - 0" 3' - 0" 5' - 0" 2 A2.5 1 A4.6 3 A2.5 5 A4.1 2 A2.6 3 A2.6 4 A0.1 A5.2 8 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 2 A4.1 1 A4.1 B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1"3' - 6"20' - 5 1/4"METER CLOSET 8624' - 1 1/4" WINDOW WELL FOR EGRESS 5' - 10"LARGE RETAINING WALL NO MORE THAN 6' EXPOSED UNDER BRIDGE W/ STONE VENEER METAL PANELS ON GARAGE DOOR VERTICAL SHIPLAP WOOD SIDING 2X2 WINDOW FRAME PAINTED BLACK (TYP IN VERT. SIDING) NO CORNER TRIM IN VERTICAL SIDING 2X6 T&G PINE SOFFIT 2X6 FASCIA OVER 2X12 SUB-FASCIA STONE VENEER WALL STEEL BEAM HORIZ. SHIPLAP WOOD SIDING VERT. SHIPLAP WOOD SIDING 62 A39a A39b 2526 08 07 1 A4.2 B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" VERTICAL SHIPLAP WOOD SIDING STANDING SEAM METAL ROOF STONE PILASTER HORIZ. SHIPLAP WOOD SIDING 2X6 WOOD CORNER TRIM 2X4 WOOD WINDOW FRAME EXPOSED STEEL BEAM FULL HEIGHT STONE VENEER COLUMN 2X6 WOOD FASCIA OVER 2X12 WOOD SUB-FASCIA 2" 12" 14 3 A4.2 3 A4.6 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 3 A4.1 4 A4.1 8615' - 9" VERTICAL SHIPLAP WOOD SIDING 2X2 WOOD WINDOW FRAME PAINTED BLACK HORIZ. SHIPLAP WOOD SIDING 2X4 WOOD WINDOW TRIM 2X6 WOOD CORNER TRIM STEEL BEAMS & POSTS METAL WINDOW FRAME EXPOSED STEEL BEAMS & POSTS STONE VENEER COLUMN BASE W/ CUT-STONE CAP HORIZ. WELDED METAL GUARDRAIL W/ WOOD CAP 2' - 10 1/2" 8609' - 4" 8606' - 1 1/4" 2" 12" 2" 12" 40 39 15 A22 38 37 A02 01 A06b 2 A2.6 3 A2.6 A5.2 5 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS9/10/2018 10:37:14 AMA3.3ELEVATIONSJG-1831 GROUSE DUPLEXPERMIT SET 8-28-189-10-18 Jarenko5128 Grouse LaneVail, CO 816571/4" = 1'-0"1 A-ELEVATION - SOUTH 1/4" = 1'-0"2 A-ELEVATION - WEST 1/4" = 1'-0"3 B-ELEVATION - EAST 1/4" = 1'-0" 4 A-ELEVATION - NORTH No. Description Date09/17/18 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0"9' - 1"11' - 0" 11' - 0" 3 A4.1 3' - 6"WINDOW WELL BRIDGE DRIVEWWAY 4 A4.1 EGRESS FIREPLACE 2" 12" 2" 12" A02 01 3837 15 A11 A22 DEN A02 BEDROOM 1 A03 CLOSET 1 A04 BATH 1 A05BUNK ROOM A09 BATH 3 A10 GARAGE A39 MUD ROOM / OWNER ENTRY A32 MASTER CLOSET A35 DINING A22 GREAT ROOM A23POWDER A27 BATH 4 A29 WC A30 DROPPED STEEL BEAM 9' - 4"8600' - 9 1/2" 8599' - 0" 8587' - 0"10' - 1"UNCONDITIONED ATTIC 5 3/4"5 3/4"SEE EXTERIOR ELEVATIONS FOR DIMENSIONS OF WINDOWS A5.1 6 Sim 4 A0.1 9' - 1"11' - 0" 11' - 0" 9' - 1"3 A4.1 4 A4.1 A21 47 49 48 GARAGE A39 8622' - 3"33' HT. LIMIT 2 A2.5 3 A2.5 2 A2.6 3 A2.6 1' - 9"7' - 0" 1' - 0" 7' - 0"58 43 59 44 60 45 61 46 22 24 23 20 W.I.C. A31 BEDROOM 3 (2ND MASTER) A28 MECHANICAL A13 LAUNDRY A12 LOWER STAIR A01 BATH 2 A08 BEDROOM 2 A06 KITCHEN A25 ENTRY CL A24 MASTER BATH A36 MASTER BEDROOM A38 EXISTING GRADE 2 A4.1 1 A4.1 2" 12"6"40 A23 05 02 03 42 41 19 17 18 06BEDROOM 1 A03 BEDROOM 2 A06 MASTER BEDROOM A38 GREAT ROOM A23 KITCHEN A25 634' - 0" 4' - 0" 4' - 0"8" 4' - 0"2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" 1. A LOWER LEVEL 8584' - 0" 2 A4.1 1 A4.1 A02 A09 A28 A38 R @ 7 3/8" 15 15 R @ 7"3 R @ 7 3/8"18 DEN A02 BATH 1 A05 LOWER STAIR A01 MASTER BEDROOM A38 MASTER CLOSET A35 MASTER BATH A36 WC A37 ENTRY A21 DINING A22 8' - 2 1/4" 9' - 11 1/4"1' - 9" 8597' - 0" T.O.WALL 9' - 1"STAIR BEYOND WITHIN PENUM SPACE 9' - 11 1/4"9' - 0"EXISTING GRADE 2 A4.1 B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" SCRATCH COAT STUCCO PAINTED TO MATCH SIDING COLOR STONE VENEER 3' - 4 1/4"EGRESS 26 25 08 07 BRIDGE FRAMING A39b EXISTING GRADE 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:27 AMA4.1A SECTIONSJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/4" = 1'-0" 2 A MAIN SECTION 1 1/4" = 1'-0"1 A MAIN SECTION 2 1/4" = 1'-0"3 A CROSS SECTION - LR 1/4" = 1'-0" 4 A CROSS SECTION- ENTRY HOUSE A - BUILDING SECTIONS 1/4" = 1'-0" 5 A WINDOW WELL SECTION 09/17/18 4 A4.2 B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" 7 A0.1 9' - 1"11' - 0" 11' - 0" 1' - 0" 0910 B20 B27a 3435 36 M1 GARAGE B01 GREAT ROOM B22 KITCHEN B23 STEEL BEAM 4 A4.2 7 A0.1 B09 MASTER BATHROOM B27 MASTER CLOSET B28 LAUNDRY B004 BEDROOM 1 B07 BEDROOM 2 B37 BATH 2 B39 BEDROOM 2 B37 DEN CL B3610' - 1"CONDITIONED ATTIC SPACE 4 A4.2 7 A0.1 B33 52 53 B27a GARAGE B01 DINING B24 PANTRY B25 BEDROOM 3 B33 4' - 0"3' - 10"8584' - 0" 8576' - 0" TO WALL TO FTG 8581' - 0" 8576' - 0" TO FTG TO WALL 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0"9' - 1"11' - 0"11' - 0"33' HEIGHT LIMIT 1 A4.2 B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0"11' - 0" 9' - 1"11' - 0"11' - 0" 11' - 0"11' - 0"EXISTING GRADE EXPOSED STEEL BEAM 2 A4.2 GARAGE B01 ENTRY B03 BEDROOM 1 B07 BATH 1 B09 GREAT ROOM B22DINING B24 MASTER BATHROOM B27 MASTER BATH B29 DEN B32 BEDROOM 3 B33 BEDROOM 2 B37 3 A4.2 4' - 0"FINISHED GRADE HOUSE A GAS METER 8592' - 0"6 5/8"TEMPERED TEMPERED 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:28 AMA4.2B SECTIONSJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/4" = 1'-0"1 B CROSS SECTION-GARAGE 1/4" = 1'-0" 2 B CROSS SECTION-GARAGE1 1/4" = 1'-0" 3 B CROSS SECTION-GARAGE2 1/4" = 1'-0"4 B MAIN SECTION 1 09/17/18 1 A4.1 4 A4.1 4 A4.3 5 A4.3 3' - 8 1/2" 5' - 6 3/4" 3' - 8 1/2"3' - 6 3/4"5' - 0 1/2"4' - 6 1/2" 2' - 8 3/4" 2X4 WALL2X6 WALL 2X6 WALL 2X4 WALL TO DRYWALL TO DRYWALLUP R @ 7 3/8"18 CONTINUOUS HANDRAIL UNDER-STAIR ELEV. EQUIP. 1-HR DRYWALL SURROUND 3' - 6 3/4" 5' - 8 3/4" 1' - 6 5/8"3' - 9 1/4" 1' - 10"10' - 6"1 A4.1 4 A4.1 4 A4.3 5 A4.3 5' - 0 1/2"4' - 6 1/2" 2' - 8 3/4" 2X4 WALL2X6 WALL 2X6 WALL 2X4 WALL TO DRYWALL TO DRYWALLR @ 7"3 R @ 7 3/8"15 R @ 7 3/8"9 ENTRY PLATFORM TEMPERED WINDOW LEDGE BELOW CABLE RAILING DOWN UP UP UP OPEN TREAD STAIR CABLE RAILING W/ WOOD CAP CABLE RAILING W/ WOOD CAP ENTRY DOOR COAT CLOSET CONTINUOUS HANDRAIL9"7' - 3" 3' - 10" 6" 1' - 9"7' - 2 5/8" 5' - 8 3/4"4' - 3 3/4" 3' - 8 1/2" 5' - 6 3/4" 6' - 1 3/4" 1 A4.1 4 A4.3 5 A4.3 2' - 8 3/4" 2X4 WALL2X6 WALL2X6 WALL2X4 WALL TO DRYWALL TO DRYWALLCABLE RAILING W/ WOOD CAPDOWN OPEN TO LEDGE BELOW R @ 7 3/8"15 4' - 2" 4' - 7 3/4" 3' - 8 1/2" 5' - 6 3/4"1' - 6"5' - 8 3/4" 4' - 3 3/4" 4' - 6 1/2"5' - 0 1/2"2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 1 A4.1 5 A4.3 ELEVATOR SHAFT 3 5/8" 7 3/8"11" HANDRAILS TO MEET IRC2015 SIZE REQ'S AT 36" HEIGHT 7 3/8"11" CABLE RAILING W/ WOOD CAP CABLE RAILING W/ WOOD CAP 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" 4 A4.1 4 A4.3 1' - 0"ENTRY PLATFORM ELEVATOR SHAFT UPPER STAIRS UNDER-STAIR ELEV EQUIP. 1-HR SEPARATION SURROUND WC A37 ENTRY A21 ENTRY CL A24 LOWER STAIR A01 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:29 AMA4.3A STAIR PLANS & SECTIONSJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/2" = 1'-0"1 A STAIR LOWER 1/2" = 1'-0"2 A STAIR MAIN 1/2" = 1'-0" 3 A STAIR UPPER 1/2" = 1'-0"4 A STAIR SECTION 1 1/2" = 1'-0"5 A STAIR SECTION 2 HOUSE A STAIRS & ELEVATOR PLANS & SECTIONS ELEVATOR SPEC: MORNING STAR ELEVATOR IN-LINE GEARED ELEVATOR CAR SIZE 40X54 ARCHITECT MUST BE NOTIFIED IF THE ELEVATOR MANUFACTURER OR SPEC CHANGES FROM THE SELECTED. 09/17/18 3 A4.6 4 A4.4 5 A4.4 6 A4.4 3' - 8 1/2" 5' - 8 3/4"5 1/2"12' - 11 3/4" 5 1/2" 3' - 8 1/2"5' - 6 3/4" 3' - 8 1/2" 4' - 6 1/2"5' - 0 1/2"2' - 8 3/4" 2X4 WALL 2X4 WALL 2X6 WALL 2X6 WALL TO DRYWALL TO DRYWALL4' - 1" 3' - 8" 1' - 8 1/4"3' - 8 5/8" 5' - 6" UP UNDER-STAIR ELEV. EQUIP. 1-HR SEPARATION SURROUND 3 A4.6 4 A4.4 5 A4.4 6 A4.4 4' - 6 1/2"5' - 0 1/2"2X4 WALL 2X4 WALL 2X6 WALL 2X6 WALL TO DRYWALL TO DRYWALL2' - 8 3/4" UP DOWN 3' - 8 1/2" 5' - 6 3/4" 3' - 8 1/2" 4' - 0 3/4" 4' - 7" 4' - 4"3' - 8 7/8" 3' - 8" 3' - 9 1/2" 5' - 5"CONTINUOUS HANDRAIL 3 A4.6 4 A4.4 5 A4.4 6 A4.45' - 1"2X4 WALL 2X4 WALL 2X6 WALL2X6 WALLTO DRYWALL TO DRYWALL2' - 8 3/4" 4' - 6 1/2" 3' - 8 1/2" 4' - 0 3/4" 4' - 7" 4' - 4" 3' - 8 1/2"6' - 8 1/4"OPEN TREAD STAIRS DOWN R @ 7 3/8"18 B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" 6 A4.4 8' - 8 5/8"7 A0.1 ELEVATOR SHAFT 11' - 0" 11' - 0"4 A4.4 5 A4.4 7 3/8"11"3 5/8"UNDER-STAIR ELEVATOR EQUIP. 1-HR SEPARATION SURROUND 7 3/8"OPEN TREAD STAIR NO 4" SPHERE MAY PASS BETWEEN TREADS HANDRAILS TO MEET IRC2015 SIZE REQ'S AT 36" HEIGHT 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:29 AMA4.4B STAIR PLANS & SECTIONSJG-1831GROUSE DUPLEX PERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/2" = 1'-0"1 B STAIR LOWER 1/2" = 1'-0"2 B STAIR MAIN 1/2" = 1'-0"3 B STAIR UPPER 1/2" = 1'-0" 4 B STAIR SECTION 1 1/2" = 1'-0" 5 B STAIR SECTION 2 1/2" = 1'-0" 6 B STAIR SECTION 3 HOUSE B STAIRS & ELEVATOR PLANS & SECTIONS ELEVATOR SPEC: MORNING STAR ELEVATOR IN-LINE GEARED ELEVATOR CAR SIZE 40X54 ARCHITECT MUST BE NOTIFIED IF THE ELEVATOR MANUFACTURER OR SPEC CHANGES FROM THE SELECTED. 09/17/18 3 A4.5 4 A4.5 5' - 2 1/2" 6' - 0" 7' - 0 1/2" 4' - 9 1/2" 6' - 4" 7' - 4"1' - 0"5 1/2"1' - 11" 6"1' - 0" 5 A4.5 6 A4.5 7' - 0 1/2"6' - 0" 4' - 6 1/2" 7' - 4"6' - 4" 3' - 11"1' - 11" 5 1/2"1' - 0"1' - 0" 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 3 A4.1 4 A4.5 10' - 0"2' - 0"3"8" 2' - 8 7/8" 1' - 9" 5' - 4 7/8"24' - 3 1/4"CHIMNEY FLUE MUST DISCHARGE ABOVE THIS LINE METAL FRAME SHROUD W/ METAL MESH PANELS 7' - 0 5/8"1' - 6 1/8"6 1/4" 2' - 8 1/4"6 1/4" CUT-STONE CAP STONE VENEER A. PLATE HT. 8615' - 1" 3 A4.5 14" B-VENT FLUE W/ 1" CLEARANCES NOTE, FULLY SEAL AND INSULATE TOP PENETRATION. 3' - 9" 3' - 0" 2' - 7 1/2" MASON-LITE 49 FIREBOX SET 18" FROM FLOOR ON CMU BLOCKS STEEL STUDS AND NO COMBUSTIBLE MATERIALS WITHIN 8" OF OPENING 1' - 6"2" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" 6 A4.5 10' - 0"2' - 0"4"7 7/8" 2' - 9" 1' - 9" 5' - 5 7/8"23' - 6 3/8"CHIMNEY FLUE MUST DISCHARGE ABOVE THIS LINE 1' - 6 1/8"6 1/4" 2' - 8 1/4"6 1/4" CUT-STONE CAP STONE VENEER A. PLATE HT. 8615' - 1" B. PLATE HT. 8612' - 1" 5 A4.5 1' - 6"14" B-VENT FLUE W/ 1" CLEARANCES NOTE, FULLY SEAL AND INSULATE TOP PENETRATION. MASON-LITE 49 FIREBOX SET 18" FROM FLOOR ON CMU BLOCKS STEEL STUDS AND NO COMBUSTIBLE MATERIALS WITHIN 8" OF OPENING 1' - 9"970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:32 AMA4.5FIREPLACE SECTIONSJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/2" = 1'-0"1 A FIREPLACE 1 1/2" = 1'-0" 2 B FIREPLACE 1 1/2" = 1'-0"3 A FIREPLACE SECTION 1 1/2" = 1'-0" 4 A FIREPLACE SECTION 2 1/2" = 1'-0" 5 B FIREPLACE SECTION 1 1/2" = 1'-0" 6 B FIREPLACE SECTION 2 HOUSE A FIREPLACE FIREPLACE SPEC: MASON-LITE MGFP49 B-VENT OPEN FLAME FIREPLACE SEE ATTACHED SPECS. ARCHITECT MUST BE NOTIFIED IF THE FIREPLACE MANUFACTURER OR SPEC CHANGES FROM THE SELECTED. HOUSE B FIREPLACE FIREPLACE SPEC: MASON-LITE MGFP49 B-VENT OPEN FLAME FIREPLACE SEE ATTACHED SPECS. MASON-LITE MODULAR FIREPLACE (PROPRIETARY SELECTION) 7 3D FIREPLACE B 8 3D FIRPLACE A 09/17/18 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" WATERPROOF MEMBRANE FROM ROOF TO RUN UP WALL 24" MIN. STEP FLASHING AND COUNTER FLASHING. SIDING TO BE KEPT OFF ROOF SURFACE BY 4" LOT SPLIT LINE NOTES: KEEP BOTH SIDES STRUCTURALLY INDEPENDENT OF EACH OTHER FROM FOUNDATION TO ROOF. NO ENCROACHMENTS WITHOUT PROPER FIRE SEPARATION AND LEGAL OWNER AGREEMENTS. SEE TOWN OF VAIL ADOPTED EXCEPTIONS TO IRC-2015 R302.1 EXCEPTION 6. SIP PANEL ROOF SIP PANEL ALIGNED WITH LOT-SPLIT LINE SOUND MITIGATION NOTE: OUTER LAYER OF GWB TO BE: NAT'L GYPSUM GOLD BOND SOUNDBREAK XP 5/8" GWB OR "QUIETROCK" OR CERTAINTEED "SILENTFX" OR SIMILAR FOR MAXIMUM STC RATING (TYP) OVER SOUND RATED HAT-CHANNELS. FLOOR FINISH: SEE SELECTIONS ON FLOOR PLANS DROPPED CEILING FOR LIGHTING FIXTURES AND SPRINKLER PIPES. BATH 2 B39 GARAGE A39 MASTER CLOSET B28 BATH 4 A29 MECH. B006 BUNK ROOM A09 5 1/2" 3" 5 1/2" 1' - 2" 7" 1' - 2"3' - 0"SPRAY FOAM INSULATION (TYP) BATT INSULATION (TYP) Section R302.1 - Exterior Walls: Section R302.1 is amended by the addition of the following: "Exception: 6. Walls, projections, openings or penetrations of two-family dwelling units with a lot line separating the units along the shared wall." 2' - 0" SOFFIT MATERIAL FASCIA: SEE RAKE DETAIL 5/8" TYPE "X" GWB CONTINUOUS WITH ONLY BREAKS AT FLOOR SHEATHING. CUT TO FIT WITHIN JOISTS SPACES AND SECURE W/ BLOCKING. 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" 5 1/2"3" 5 1/2" 7" 1' - 2" BATH 2 B39 MASTER CLOSET B28 LAUNDRY B004 CLOSET A11 DINING A22 WATERPROOF MEMBRANE FROM ROOF TO RUN UP WALL 24" MIN. STEP FLASHING AND COUNTER FLASHING. SIDING TO BE KEPT OFF ROOF SURFACE BY 4" STICK-FRAMING ALIGNED WITH LOT-SPLIT LINE FURRING WALL FOR PLUMBING FURRING WALL FOR PLUMBING SIP ROOF PANEL 5/8" TYPE "X" GWB CONTINUOUS WITH ONLY BREAKS AT FLOOR SHEATHING. CUT TO FIT WITHIN JOISTS SPACES AND SECURE W/ BLOCKING. 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" 1. A LOWER LEVEL 8584' - 0" B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. GARAGE LEVEL 8580' - 0" STAIR B02 STAIR B21 DEN B32 EXTERIOR W.P DECK SEE DETAILS CONC. PATIO SLAB INTERIOR STAIRS SEE DETAILS INTERIOR STAIRS SEE DETAILS 5/8" TYPE "X" GWB CONTINUOUS WITH ONLY BREAKS AT FLOOR SHEATHING. CUT TO FIT WITHIN JOISTS SPACES AND SECURE W/ BLOCKING. 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" B. GARAGE LEVEL 8580' - 0" WC B30 BEDROOM 2 B37 8587' - 0" 8580' - 8" WINDOW WELL UNDER- BRIDGE DRIVEWAY BRIDGE TOP OF FOUNDATION WALL STUCCO SCRATCH COAT PAINTED BRIDGE: SEE DETAILS ROOF OVER BRIDGE SIP ROOF PANELS FURRING FOR PLUMBING GRAVEL 4' - 0" ROOF OVERHANG LOT SPLIT LINE NOTES: KEEP BOTH SIDES STRUCTURALLY INDEPENDENT OF EACH OTHER FROM FOUNDATION TO ROOF. NO ENCROACHMENTS WITHOUT PROPER FIRE SEPARATION AND LEGAL OWNER AGREEMENTS. SEE TOWN OF VAIL ADOPTED EXCEPTIONS TO IRC-2015 R302.1 EXCEPTION 6. UNIT A METER CLOSET MAINTAIN 1 HR SEPARATION DETAIL AT PARTY WALL 8596' - 0" 8596' - 0" TO WALL BEYOND 5/8" TYPE "X" GWB CONTINUOUS WITH ONLY BREAKS AT FLOOR SHEATHING. CUT TO FIT WITHIN JOISTS SPACES AND SECURE W/ BLOCKING. 2. A MAIN LEVEL 8595' - 0" 3. A UPPER LEVEL 8606' - 0" A. PLATE HT. 8615' - 1" 1. A LOWER LEVEL 8584' - 0" B LOWER LEVEL 8581' - 0" B MAIN LEVEL 8592' - 0" B UPPER LEVEL 8603' - 0" B. PLATE HT. 8612' - 1" 1' - 2" TREX (OR SIM) DRIP-THRU DECKING OVER 2X10 FRAMING 8591' - 10" 8580' - 8" TO WALL TO FTG WINDOW WELL WALL BEYOND LOT SPLIT LINE NOTES: KEEP BOTH SIDES STRUCTURALLY INDEPENDENT OF EACH OTHER FROM FOUNDATION TO ROOF. NO ENCROACHMENTS WITHOUT PROPER FIRE SEPARATION AND LEGAL OWNER AGREEMENTS. SEE TOWN OF VAIL ADOPTED EXCEPTIONS TO IRC-2015 R302.1 EXCEPTION 6. HEATED GARAGE DECK SEE DETAILS GUARDRAIL SEE DETAILS 8590' - 0" GRADE AT WALL STONE PILASTER BEYOND AIR CONDITIONER CONDENSER DRIVEWAY BRIDGE 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS9/10/2018 10:37:15 AMA4.6PARTY WALL SECTIONSJG-1831GROUSE DUPLEX PERMIT SET 8-28-189-10-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/2" = 1'-0"1 PARTY WALL SECTION 1 1/2" = 1'-0" 2 PARTY WALL SECTION 2 1/2" = 1'-0" 3 PARTY WALL SECTION 3 1/2" = 1'-0" 4 PARTY WALL SECTION 4 1/2" = 1'-0" 5 PARTY WALL SECTION 5 PARTY WALL CONSTRUCTION OPTIONS FOR 1 -HOUR SEPARATION (1 HR SEPARATION TO LOT -SPLIT LINE) 09/17/18 MAIN LEVEL T.O.PLY. FIELD INSTALLED BOTTOM PLATE TREATED SILL PLATE BASEMENT MAIN LEVEL RIM JOIST SIDING - SEE ELEVATIONS BELLY -BAND TRIM R-48 BLOWN -IN CELLULOSE INSULATION WALL SHEATHING 2" 4"4" WOOD LEDGE 1 1/2" STYROFOAM INSUL. STONE VENEER W/ AIRSPACE AND WEEPHOLES -OVER- 2" "DOW" (OR EQUAL) STYROFOAM INSULATION = R-10 SUPPORTED ON EXTRA DEEP STEEL ANGLE BOLTED TO CONC. WALL 2x4 FURRING WALL W/ BLOWN-IN CELLULOSE = R-14 -OVER- 1" RIGID INSUL FOR CONTINUOUS THERMAL BREAK= R-4 5/8" TYPE X GWB OVER VAPOR BARRIER FOUNDATION PROTECTION SYSTEM: SEE BASEMENT WALL DETAIL AT HEATED SLABS: 2" RIGID INSULATION OVER 4" GRAVEL 5/8" TYPE X GWB STONE VENEER BASE TRIM (PROFILE TBD) MAIN LEVEL T.O PLY. 5/8" GWB OVER VAPOR BARRIER BASEMENT MAIN LEVEL 2x4 FURRING WALL R-13 BIBS -OVER- R-4 RIGID INSUL (1") FOR CONTINUOUS THERMAL BREAK R-48 BLOWN -IN CELLULOSE INSULATION 1 1/2"4"4" 5/8" GWB SIDING - SEE ELEVATIONS OVER WEATHER BARRIER HOUSE WRAP SEE ENERGY SHEET A.01 FOR WALL INSULATION DETAIL R-10 UNDER-SLAB RIGID BOARD INSULATION (2") CONC SLAB (UNHEATED) GRANULAR FILL - INCLUDE SOIL-GAS (RADON) VENTILATION SYSTEM. REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION/FOOTING DESIGN AND REINFORCEMENT SLOPED 4" PERFORATED DRAIN PIPE. ALL FOUNDATION WALLS INCLUDING INTERIOR WALLS. RE: SOILS REPORT BASE TRIM (PROFILE TBD) FINISH GRADE: 6" BELOW SILL PLATE MIN. SLOPE AWAY POLYETHYLENE VAPOR BARRIER OSB SHEATHING TO OVERLAP SILL PLATE 2" FLOOR FINISH MATERIAL BASE TRIM (PROFILE TBD) LEDGER (NON-BOLTING ALTERNATIVE) GWB HELD UP FROM SLAB 3/8" FREE-DRAINING BACKFILL DAMPROOFING OR W.P. MEMBRANE FOR CAPILLARY BREAK2 1/4"1' - 2 1/4"TREATED WOOD SILL PLATE, SEALANT UNDER PLATE FOR CAPILLARY BREAK. FILTER FABRIC (R-10) 2-3/8" DRAIN & DRY" DRAINAGE BOARD OVER WATERPROOFING (FROM FOOTING TO 8" BELOW FINISHED GRADE) ALTERNATE SYSTEM: COMPOSITE DRAINAGE BOARD WITH FILTER FABRIC EXTEND FROM 8" BELOW GRADE TO FOOTING OVER 2" RIGID INLSULATION (TO A DEPTH OF 4'-0" BELOW GRADE) OVER WATERPROOFING. ADDITIONAL 4" PERFORATED DRAIN PIPE AT 10'-0" VERTICAL SPACING AT ALL UPHILL FOUNDATION WALLS IN EXCESS OF 15' IN HT COVER RIGID INSULATION W/ METAL FLASHING R-5 RIGID INSULATION FOR THERMAL BREAK (3/4”) MAIN LEVEL T.O.PLY. TREATED SILL PLATE W/ CAPILLARY BREAK RIM JOIST SIDING - SEE ELEVATIONS OVER WEATHER BARRIER HOUSE WRAP BELLY -BAND TRIM R-48 BLOWN -IN CELLULOSE INSULATION SEE ENERGY SHEET A.01 FOR 2X6 STUD WALL INULATION DETAIL. EXTERIOR OSB SHEATHING 2" 4"4" 4' - 0"NOTE: SLAB TO EXTEND AT SPECIAL CONDITIONS RE: STRUCT. DWGS.MIN. FROST DEPTH5/8" GWB R-10 METAL VENEER OVER 2" RIGID INSULATION R-10 UNDER-SLAB RIGID BOARD INSULATION (2") CONC SLAB (UNHEATED) GRANULAR FILL - INCLUDE SOIL-GAS (RADON) VENTILATION SYSTEM REFER TO STRUCTURAL DRAWINGS FOR FOUNDATION/FOOTING DESIGN AND REINFORCEMENT SLOPED 4" PERFORATED DRAIN PIPE. ALL FOUNDATION WALLS INCLUDING INTERIOR WALLS. RE: SOILS REPORT GWB HELD UP FROM SLAB 3/8” BASE TRIM (PROFILE TBD) SLOPED FLASHING & COUNTER- FLASHING - SEAL AND CAULK FINISH GRADE: 6" BELOW SILL PLATE MIN. SLOPE AWAY POLYETHYLENE VAPOR BARRIER OSB SHEATHING TO OVERLAP SILL PLATE 2" R-5 RIGID INSULATION FOR THERMAL BREAK (3/4”) FREE-DRAINING BACKFILL DAMPROOFING OR W.P. MEMBRANE FOR CAPILLARY BREAK FILTER FABRIC (R-10) 2-3/8" DRAIN & DRY" DRAINAGE BOARD OVER WATERPROOFING (FROM FOOTING TO 8" BELOW FINISHED GRADE) ALTERNATE SYSTEM: COMPOSITE DRAINAGE BOARD WITH FILTER FABRIC EXTEND FROM 8" BELOW GRADE TO FOOTING OVER 2" RIGID INLSULATION (TO A DEPTH OF 4'-0" BELOW GRADE) OVER WATERPROOFING. 5/8" GWB OVER VAPOR BARRIER MAIN LEVEL SEE ENERGY SHEET A.01 FOR WALL INSULATION DETAIL FLOOR FINISH MATERIAL BASE TRIM (PROFILE TBD) 2X6 FASCIA 2X12 SUB-FASCIA 5/8” GWB CEILING FINISH1' - 0 1/4"S I P PANEL = +R -49 SIDING - SEE ELEVATIONS METAL ROOFING W.P. MEMBRANE GALV. MTL FLASHING 5 1/2" 2' - 6" SEE ENERGY SHEET A.01 FOR WALL INSULATION DETAIL 2'-0" OR AS NOTED ON ROOF PLAN DROPPED CEILING WHERE NEEDED FOR RECESSED LIGHTING FIXUTES AND FIRE SPRINKLER PIPES SIP PANELS TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS AND SHOP DRAWINGS. 1X6 CEDAR SOFFIT METAL ROOFING W.P. MEMBRANE GALV. MTL FLASHING 2X6 FASCIA 2X12 SUB-FASCIA1' - 0 1/4"SIP PAN E L = +R-49 SIDING - SEE ELEVATIONS 5 1/2" 3' - 0" SEE ENERGY SHEET A0.1 FOR WALL INSULATION DETAIL 2'-0" OR AS NOTED ON ROOF PLAN 1X4 T&G CEDAR SOFFIT 5/8” GWB CEILING FINISH DROPPED CEILING WHERE NEEDED FOR RECESSED LIGHTING FIXUTES AND FIRE SPRINKLER PIPES SIP PANELS TO BE INSTALLED PER MANUFACTURER SPECIFICATIONS AND SHOP DRAWINGS. SNOW RETENTION DEVICE DESIGN AND ENGINEERING BY OTHERS 1' - 0 1/4"1' - 0 1/4"12 1/4" SIP CANTILEVER SIP 1X6 T&G SOFFIT PANELS SIDING - SEE ELEVATIONS 12 1/4" SIP 1' - 6" WATERPROOF MEMBRANE FROM ROOF TO RUN UP WALL 24" MIN. STEP FLASHING AND COUNTER FLASHING. SIDING TO BE KEPT OFF ROOF SURFACE BY 4" SIP PANEL TIGHT TO WALL R-13 BATT INSULATION TO FILL REMAINDER OF 2X6 STUD WALL CAVITY. R-13 SRRAY 2" OF FOAM INSULATION ON INTERIOR FACE OF EXTERIOR WALL SHEATHING WELDED METAL RAILING W/ WOOD CAP 1 1/2"3 1/2" 2' - 11"MAIN LEVEL T.O.PLY. R-50 BLOWN -IN CELLULOSE INSULATION WATER PROOFING MEMBRANE TO EXTEND UP WALL 24" OR UP AND UNDER THRESHOLD STONE FLAGSTONE ON THICKSET MORTAR W/ RADIANT HEATING TUBES OPTION ON FILTER FABRIC WITH DRAINAGE MEDIUM ON 2 LAYERS OF WATERPROOF MEMBRANE ON FLOOR SHEATHING ON FLOOR JOIST WITH TOPS CUT AT A SLOPE (1/4" PER FOOT) PROVIDE WALL TO FLOOR FLASHING AT BASE OF WOOD SIDING DOOR THRESHOLD BEYOND 14" LVL W/ RIPPED TOP 1"VARIES 1' - 0 3/4"INSULATION TO MEET IRC MINIMUMS SPRAY FOAM INSULATION REQ'D OR DROPPED CEILING OPTION THICKER STONES AT PERIMETER FLASHING ROPE WICKS AT 2'-0" O.C.3' - 0"RIM JOIST W/ KERF T&G ON UNDERSIDE OF RIPPED FLOOR JOIST 1" STEEL BEAM -VARIES - RE: STRUCT STONE PIER - VARIES SLOPED STONE CAP FINISH VAIRIES 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:32 AMA5.1DETAILSJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 816571" = 1'-0"1 DETAIL - BASEMENT - CONC STUB 1" = 1'-0" 2 DETAIL - FOUND. @ FIN BASEMENT 1" = 1'-0" 3 DETAIL - FOUNDATION SLAB-ON-GRADE 1" = 1'-0"8 DETAIL - ROOF HIGH EAVE 1" = 1'-0" 9 DETAIL - ROOF LOW EAVE 1" = 1'-0"5 DETAIL - ROOF TO WALL - RAKE No. Description Date1" = 1'-0"4 RAILING DETAIL 1" = 1'-0" 6 DETAIL - FLOOR - WP DECK - OPEN 09/17/18 VERTICAL BONDERIZED CORRUGATED METAL SIDING ((RE: ELEVS) OVER TYPICAL WALL DETAIL WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS. SEAL/FOAM THE PERIMETER OF ALL PENETRATIONS WATERPROOF MEMBRANE WINDOW TAPE OVER NAILING FLANGE SEALANT BEHIND NAILING FLANGE STRUCTURAL HEADER, W/ RIGID INSULATION. WOOD CASING PROFILE TBD BACKER ROD AND SEALANT SHIM SPACE 2X2 WOOD SILL W/ SLOPED TOP WATERPROOF MEMBRANE TAPE TO OVERLAP AIR - INFILTRATION BARRIER AND EXTEND OVER ROUGH SILL FLASHING 3X6 WOOD HEADER (RE: ELEVS) W/ SLOPED TOP HEAD FLASHING AT ALL WINDOW AND DOOR HEADS SIDE TRIM: 2X2 TRIM AT METAL & VERT. T&G SIDING EXTERIOR 1 1/2" 2 1/2" 1 1/2"1 1/2"2"1 7/8"HEADER TRIM: 2X2 TRIM SILL TRIM: 2X2 TRIM HEAD FLASHING AT ALL WINDOW AND DOOR HEADS HORIZONTAL SIDING ON THERMAL AND AIR INFILTRATION BARRIER ON 1/2" SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH 2" SPRAY FOAM INSULATION (R-13) BLOWN-IN BATTS R-13 INSULATION BETWEEN STUDS (TOTAL=R-26) . MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON WALL FLASHING 2X4 RS CEDAR HEADER (RE: ELEVS) W/ SLOPED TOP WATERPROOF MEMBRANE WINDOW TAPE OVER NAILING FLANGE 2x4 CEDAR WOOD SILL W/ SLOPED TOP 2X4 R.S. CEDAR WOOD JAMB AT HORIZONTAL SIDING EXTERIOR HEAD FLASHING AT ALL WINDOW AND DOOR HEADS STONE VENEER ON THERMAL AND AIR INFILTRATION BARRIER ON 1/2" SHEATHING ON 2X6 WOOD STUD WALL FRAMING WITH 2" SPRAY FOAM INSULATION (R-13) BLOWN-IN BATTS R-13 INSULATION BETWEEN STUDS (TOTAL=R-26) . MEMBRANE VAPOR RETARDER AND 5/8" TYPE 'X' GYPSUM WALL BOARD ON WALL 10" STEEL 1/2 FLANGE I-BEAM HEADER WATERPROOF MEMBRANE WINDOW TAPE OVER NAILING FLANGE AT STONE EXTERIOR 6" NOMINAL THICK STONE VENEER ON DRAINAGE PLAIN SYSTEM WITH WEEPS AT BOTTOM OF THE WALL 2" CUT STONE SILL (RE: ELEVS) W/ SLOPED TOP NO JAMB VYCOR WATERPROOF TAPE AT THE PERIMETER OF ALL OPENINGS. 1 1/2"1 1/2"1 1/2" 2X2 HEADER 2X2 SIDE TRIM 3 1/2"3 1/2" 2X4 HEADER 2X4 SIDE TRIM 12' - 0" 4' - 0" 4' - 0" 4' - 0"8' - 0" 8" 4' - 0"2. A MAIN LEVEL 8595' - 0" 6' - 0" 4' - 0" 2' - 0"2' - 8" 5' - 4" 8" 4' - 1"TEMPERED AWNING TEMPERED B MAIN LEVEL 8592' - 0"2' - 10"2' - 6" 8" 5' - 6" 2' - 6" 2' - 0"4' - 0" 6' - 0" TEMPERED AWNING TEMPERED B MAIN LEVEL 8592' - 0"8' - 0" 8" 2' - 6" 1' - 4"5' - 10"4' - 0"4' - 0" 4' - 0" 2' - 6" 3' - 4"12' - 0" FIXED TEMPERED AWNING TEMPERED FIXED TEMPERED FIXED TEMPERED FIXED FIXED FIXED FIXED 8' - 0" 5' - 0" 3' - 0"5' - 0"2' - 0" 1' - 0" 5' - 0" 2' - 0" 6' - 0" 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS9/10/2018 10:37:17 AMA5.2WINDOW/DOOR SCHEDULESJG-1831GROUSE DUPLEX PERMIT SET 8-28-189-10-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description DateWINDOW SCHEDULE Mark Window Type Width Height Head Height Comments 01 Casement 3' - 0" 5' - 0" 8' - 0" EGRESS 02 Casement 5' - 0" 5' - 0" 8' - 0" 03 Casement 3' - 0" 5' - 0" 8' - 0" 05 Casement 2' - 6" 5' - 0" 8' - 0" EGRESS 06 Casement 2' - 6" 5' - 0" 8' - 0" EGRESS 07 Casement 3' - 0" 4' - 6" 8' - 0" EGRESS 08 Casement 3' - 0" 4' - 6" 8' - 0" EGRESS 09 Casement 3' - 0" 5' - 0" 8' - 6" EGRESS 10 Casement 3' - 0" 5' - 0" 8' - 6" EGRESS 11 Casement 3' - 0" 3' - 4" 8' - 6" 12 Awning 3' - 0" 1' - 8" 5' - 2" 13 Casement 5' - 0" 5' - 0" 8' - 6" 14 Casement 5' - 0" 5' - 0" 8' - 6" 15 Fixed 6' - 0" 6' - 0" 8' - 0" TEMPERED 17 Casement 3' - 0" 3' - 4" 8' - 6" 18 Awning 3' - 0" 1' - 8" 5' - 2" 19 Casement 5' - 0" 5' - 0" 8' - 6" 20 Casement 5' - 0" 5' - 0" 8' - 6" 21 Awning 2' - 6" 1' - 8" 8' - 0" 22 Casement 5' - 0" 5' - 0" 8' - 6" 23 Casement 3' - 0" 3' - 4" 8' - 6" EGRESS 24 Awning 3' - 0" 1' - 8" 5' - 2" 25 Casement 3' - 0" 4' - 0" 8' - 0" 26 Casement 3' - 0" 4' - 0" 8' - 0" 27 Fixed 4' - 0" 4' - 0" 8' - 0" 28 Fixed 3' - 6" 3' - 4" 8' - 0" 29 Awning 3' - 6" 1' - 8" 1' - 8" 30 Fixed 5' - 6" 5' - 0" 8' - 0" 31 Fixed 3' - 6" 3' - 4" 8' - 0" 32 Awning 3' - 6" 1' - 8" 1' - 8" 33 Fixed 5' - 6" 5' - 0" 8' - 0" 34 Awning 4' - 0" 1' - 8" 8' - 0" 35 Awning 4' - 0" 1' - 8" 8' - 0" 36 Awning 2' - 6" 1' - 8" 7' - 0" 37 Awning 3' - 6" 2' - 6" 8' - 6" 38 Awning 3' - 6" 2' - 6" 8' - 6" 39 Awning 5' - 0" 2' - 0" 8' - 0" 40 Awning 5' - 0" 2' - 0" 8' - 0" 41 Casement 3' - 0" 4' - 4" 8' - 0" 42 Fixed 6' - 0" 6' - 0" 8' - 0" 43 Casement 3' - 0" 4' - 6" 8' - 0" 44 Casement 3' - 0" 4' - 6" 8' - 0" 45 Fixed 5' - 0" 4' - 6" 8' - 0" 46 Casement 3' - 0" 4' - 6" 8' - 0" 47 Casement 5' - 0" 5' - 0" 8' - 6" 48 Awning 3' - 0" 1' - 8" 5' - 2" 49 Casement 3' - 0" 3' - 4" 8' - 6" 50 Casement 5' - 0" 5' - 0" 8' - 0" 51 Awning 5' - 0" 1' - 8" 6' - 8" 52 Casement 3' - 0" 5' - 0" 8' - 0" 53 Awning 3' - 0" 1' - 8" 9' - 8" 54 Casement 3' - 0" 5' - 0" 8' - 0" 55 Casement 5' - 0" 5' - 0" 8' - 0" 56 Casement 3' - 0" 5' - 0" 8' - 0" 57 Casement 5' - 0" 5' - 0" 8' - 0" 58 Awning 3' - 0" 1' - 8" 9' - 8" 59 Awning 3' - 0" 1' - 8" 9' - 8" 60 Awning 5' - 0" 1' - 8" 9' - 8" 61 Awning 3' - 0" 1' - 8" 9' - 8" 62 Fixed 6' - 0" 4' - 0" 14' - 6 1/4" 63 Awning 3' - 0" 1' - 8" 3' - 8" Door Schedule Mark Width Height Comments A00 3' - 0" 7' - 0" ELEVATOR A02 6' - 0" 8' - 0" A03 2' - 8" 7' - 6" A04 5' - 0" 7' - 6" A05 2' - 4" 7' - 0" A06a 2' - 8" 7' - 6" A06b 2' - 6" 8' - 0" A07 4' - 0" 7' - 6" A09 2' - 4" 7' - 0" A09 2' - 8" 7' - 6" A10a 2' - 4" 7' - 6" A10b 2' - 4" 7' - 0" A11 5' - 0" 7' - 6" A12 2' - 8" 7' - 6" A13 3' - 0" 7' - 6" A20 3' - 0" 7' - 0" ELEVATOR A21 5' - 0" 7' - 10 1/2" CUSTOM FRONT DOOR A22 2' - 6" 8' - 0" A23 12' - 0" 8' - 0" A24 4' - 0" 7' - 6" A25 2' - 6" 8' - 0" A26 2' - 4" 7' - 0" A27 2' - 6" 7' - 6" A28 2' - 8" 7' - 6" A29 2' - 6" 7' - 6" A30 2' - 6" 7' - 6" A31a 2' - 6" 7' - 6" A31b 2' - 4" 7' - 0" A32 3' - 0" 7' - 6" SELF-CLOSING 45 MIN. A34 3' - 0" 7' - 0" ELEVATOR A35 3' - 0" 7' - 6" A36 3' - 0" 7' - 6" A37 2' - 4" 7' - 0" A38 3' - 0" 7' - 6" A39a 18' - 0" 8' - 0" A39b 3' - 0" 8' - 0" B00 3' - 0" 7' - 0" B01a 2' - 11 1/4" 6' - 10" B01b 9' - 0" 8' - 0" B01c 9' - 0" 8' - 0" B03a 6' - 0" 8' - 0" CUSTOM FRONT DOOR B03b 3' - 0" 7' - 6" SELF-CLOSING 45 MIN. B03c 2' - 8" 7' - 6" B03d 2' - 8" 7' - 6" B03e 2' - 4" 7' - 6" B03g 2' - 4" 7' - 6" B03h 5' - 0" 7' - 6" B03i 4' - 0" 7' - 6" B04 2' - 8" 7' - 6" B05 4' - 0" 7' - 6" B06 2' - 8" 7' - 6" B07 2' - 8" 7' - 6" B08 4' - 0" 7' - 6" B09 2' - 4" 7' - 0" B20 3' - 0" 7' - 0" B22 12' - 0" 8' - 0" B24 2' - 6" 8' - 0" B25 2' - 4" 7' - 0" B26 2' - 4" 7' - 0" B27a 3' - 0" 7' - 6" B27b 2' - 6" 8' - 0" B28 2' - 4" 7' - 0" B29 2' - 4" 7' - 0" B30 2' - 4" 7' - 0" B31 3' - 0" 7' - 0" B33 3' - 0" 7' - 6" B37 5' - 0" 7' - 6" B38 3' - 0" 6' - 8" B39a 2' - 6" 7' - 6" B39b 2' - 6" 7' - 6" B40 3' - 0" 7' - 6" B41 4' - 0" 7' - 6" 1 1/2" = 1'-0"1 WINDOW DETAILS 1 1/2" = 1'-0" 2 WINDOW HEAD ELEV - METAL 1 1/2" = 1'-0"3 WINDOW HEAD ELEV - WOOD R308.4.3 Glazing in windows. Glazing in an individual fixed or operable panel that meets all of the following conditions shall be considered a hazardous location: 1. The exposed area of an individual pane is larger than 9 square feet (0.836 m2); 2. The bottom edge of the glazing is less than 18 inches (457 mm) above the floor; 3. The top edge of the glazing is more than 36 inches (914 mm) above the floor; and 4. One or more walking surfaces are within 36 inches (914 mm), measured horizontally and in a straight line, of the glazing. WINDOW NOTES: 1. ALL WINDOWS SHALL BE DOUBLE-PANED WOOD WINDOWS W/ ALUM. CLADDING OR FIBERGLASS UNLESS OTHERWISE NOTED. 2. U-VALUE OF .30 MAXIMUM (SEE INSULATION SUMMARY). 3. ALL WINDOWS TO RECEIVE LOW-E TREATMENT. 4. ALL SIZES SHOWN ARE NOMINAL. CONTRACTOR TO VERIFY ROUGH-OPENING SIZES WITH CHOSEN WINDOW MANUFACTURER. 5. WINDOWS MUST DISPLAY MANUFACTURER SPECS INCLUDING R-VALUES PRIOR TO COUNTY INSPECTIONS. DOOR NOTES: 1. DOOR MAKE & MODEL & WOOD TYPE SELECTION BY OWNER/CONTRACTOR. 2. HARDWARE SELECTIONS BY OWNER/CONTRACTOR. 1/2" = 1'-0" 4 WINDOWS A EAST 1/2" = 1'-0" 5 WINDOWS A NORTH 1/2" = 1'-0"6 WINDOWS B - EAST 1/2" = 1'-0"7 WINDOWS B NORTH 1/2" = 1'-0" 8 WINDOWS A SOUTH 09/17/18 4 A4.2 4 A4.2 1 A4.2 1 A4.2 2 A4.1 2 A4.1 1 A4.1 1 A4.1 3 A4.1 3 A4.1 4 A4.1 4 A4.1 7 A0.1 7 A0.1 4 A5.1 2 A4.2 3 A4.2 3 A4.2 WP CONTRACTOR TO VERIFY ELECT. REQ. AND LOCATIONS IN MECH RM. WP WP JS JS JS JS S/CJS 2 A2.5 1 A4.6 2 A4.6 3 A4.6 4 A4.6 5 A4.6 3 A2.5 5 A4.1 2 A2.6 3 A2.6 4' - 0" 5' - 8" 3' - 0"3' - 6"4' - 0" 3' - 0"4' - 6"4' - 6"4' - 0"4' - 0" 5' - 2" 5' - 6"1' - 6" 5' - 2 3/4" 1' - 6"9' - 4 1/2" 3' - 0" ELEV. EQUIP.S/CS/C S/C S/C S/C S/C G1 G2 LIGH T ROPE AR OU N D CO F FER (OP TION ) CO FFERED CEILING DECK SOFFIT DROPPED CEILING NOTES: * DROPPED CEILING SHOWN WITH LIGHT GRAY SOLID HATCH. * DROPPED CEILING SET AT 9'-1" C.H. CONTRACTOR MUST VERIFY WITH MECH. DUCT COORDINATION. * LIGHT FIXTURES DIRECTLY BELOW MECH. TRUNK LINE MAY NEED TO BE SHALLOW FIXTURES OR CEILING MOUNTED FIXTURES. * DROPPED CEILING AT SIP PANELS WILL SLOPE WITH SIP AND BE COORDINATED WITH LIGHT FIXTURES AND FIRE-SPRINKLER PIPING. SUGGESTED MECH. DUCT TRUNK LINE SUGGESTED MECH. DUCT TRUNK LINE MECH. CHASE MECH. CHASE UP TO SWITCH ABOVE 220V WP UP TO NEXT FIXT. UNDER STAIR UNDER STAIR 4 A0.1 3' - 5 1/2" 4' - 0" SEE SHEET A4.4 FOR ELECTRICAL REQUIREMENTS FOR ELEV. SEE SHEET A4.4 FOR ELECTRICAL REQUIREMENTS FOR ELEV. WP RECESSED CAN LIGHT (wet location) RECESSED CAN LIGHT (sloped ceiling fixture) RECESSED CAN LIGHT (directional spot) CEILING MOUNTED CHANDELIER RECESSED CAN LIGHT WALL MOUNTED SCONCE FIXTURE CEILING FAN UNDERCABINET LIGHT FLUORESCENT CLOSET LIGHT (JS=JAMB SWITCH) CEILING EXHAUST FAN STEP LIGHT 1/2 HOT DUPLEX OUTLET ELECTRICAL / LIGHTING LEGEND DUPLEX OUTLET RECEPTACLE SINGLE SWITCH 3-WAY SWITCH DIMMER SWITCH CEILING MOUNTED SCONCE OR PENDANT 120V UL 217 SMOKE / UL 2034 CARBON MONOXIDE COMBO M MOTION SENSOR LIGHT CEILING MOUNT RECESSED FLOOR / CEILING DUPLEX OUTLET / SPECIAL POWER SUPPY UP WALL UPLIGHTING FAN CONTROLS S/C FLUORESCENT STRIP LIGHT GFCI DUPLEX OUTLET PHONE/DATA OUTLET CABLE/COAX OUTLET OTHER NOTES * PROVIDE DOOR BELL CHIME AT EACH LEVEL. * PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPELOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR. * ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL. *ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS. * ALL IGNITION POINTS OF GAS FIRED MECH. EQUIP. SHALL BE 18" A.F.F. OF GARAGE (WHEN MECH IS LOCATED ADJACENT OR WITHIN THE GARAGE). LIGHTING NOTES GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENTS SECTION N1104.1 LIGHTING EQUIPMENT: A MINIMUM OF 92 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. GFCI OUTLET PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY, DISHWASHERS GARAGES, MECH. ROOMS. ARC-FAULT CIRCUIT INTERRUPTER AFCI PROTECTION IS REQUIRED ON ALL BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, AND SIMILAR ROOMS AND AREAS. OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15 AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A COVER AND WEATHERPROOF WHILE IN USE OT NOT 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:35 AMA6.1RCP/ELEC -LOWERJG-1831 GROUSE DUPLEXPERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/4" = 1'-0"1 1. A LOWER RCP 1/4" = 1'-0" ELECTRICAL SYMBOL LEGEND 09/17/18 4 A4.2 1 A4.2 1 A4.2 2 A4.1 2 A4.1 1 A4.1 1 A4.1 3 A4.1 3 A4.1 4 A4.1 4 A4.1 7 A0.1 7 A0.1 S/C 3 A4.2 3 A4.2 WP 2 A2.5 1 A4.6 2 A4.6 3 A4.6 4 A4.6 5 A4.6 3 A2.5 5 A4.1 2 A2.6 3 A2.6 6' - 0"2' - 0"1' - 8" 3' - 0" 3' - 0"6' - 9 1/4"5' - 6"6' - 6" 3' - 0"4' - 0" 2' - 6" 3' - 6 1/2"2' - 6"2' - 0" 6' - 0" 2' - 6 1/4"WP DROPPED CEILING NOTES: * DROPPED CEILING SHOWN WITH LIGHT GRAY SOLID HATCH. * DROPPED CEILING SET AT 9'-1" C.H. CONTRACTOR MUST VERIFY WITH MECH. DUCT COORDINATION. * LIGHT FIXTURES DIRECTLY BELOW MECH. TRUNK LINE MAY NEED TO BE SHALLOW FIXTURES OR CEILING MOUNTED FIXTURES. * DROPPED CEILING AT SIP PANELS WILL SLOPE WITH SIP AND BE COORDINATED WITH LIGHT FIXTURES AND FIRE-SPRINKLER PIPING. SUGGESTED MECH. DUCT TRUNK LINE DROPPED STEEL BEAM SUGGESTED MECH. DUCT TRUNK LINE DROPPED STEEL BEAM MECH. CHASE MECH. CHASE LIGHT RO PE AR O U N D CO F F ER (OP TION) CO FFE RED CEILING LIGHT ROPE AROUND COFFER (OPTION) COFFERED CEILING LIGHT ROPE AROUND COFFER (OPTION) COFFERED CEILING CO FFE R E D CE ILING LIGH T RO PE AR O UN D CO FFER (OPTIO N) UP TO FIXT. ABOVE DN TO WALL FIXT. BELOW HOOD 4 A0.1 JS UP TO FIXT. UP TO FIXT. DN TO FIXT. WP WP WP S/C S/ C S/C WP RECESSED CAN LIGHT (wet location) RECESSED CAN LIGHT (sloped ceiling fixture) RECESSED CAN LIGHT (directional spot) CEILING MOUNTED CHANDELIER RECESSED CAN LIGHT WALL MOUNTED SCONCE FIXTURE CEILING FAN UNDERCABINET LIGHT FLUORESCENT CLOSET LIGHT (JS=JAMB SWITCH) CEILING EXHAUST FAN STEP LIGHT 1/2 HOT DUPLEX OUTLET ELECTRICAL / LIGHTING LEGEND DUPLEX OUTLET RECEPTACLE SINGLE SWITCH 3-WAY SWITCH DIMMER SWITCH CEILING MOUNTED SCONCE OR PENDANT 120V UL 217 SMOKE / UL 2034 CARBON MONOXIDE COMBO M MOTION SENSOR LIGHT CEILING MOUNT RECESSED FLOOR / CEILING DUPLEX OUTLET / SPECIAL POWER SUPPY UP WALL UPLIGHTING FAN CONTROLS S/C FLUORESCENT STRIP LIGHT GFCI DUPLEX OUTLET PHONE/DATA OUTLET CABLE/COAX OUTLET OTHER NOTES * PROVIDE DOOR BELL CHIME AT EACH LEVEL. * PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPELOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR. * ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL. *ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS. * ALL IGNITION POINTS OF GAS FIRED MECH. EQUIP. SHALL BE 18" A.F.F. OF GARAGE (WHEN MECH IS LOCATED ADJACENT OR WITHIN THE GARAGE). LIGHTING NOTES GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENTS SECTION N1104.1 LIGHTING EQUIPMENT: A MINIMUM OF 92 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. GFCI OUTLET PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY, DISHWASHERS GARAGES, MECH. ROOMS. ARC-FAULT CIRCUIT INTERRUPTER AFCI PROTECTION IS REQUIRED ON ALL BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, AND SIMILAR ROOMS AND AREAS. OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15 AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A COVER AND WEATHERPROOF WHILE IN USE OT NOT 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:37 AMA6.2RCP/ELEC -MAINJG-1831GROUSE DUPLEX PERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/4" = 1'-0"1 2. A MAIN RCP 1/4" = 1'-0" ELECTRICAL SYMBOL LEGEND 09/17/18 4 A4.2 4 A4.2 1 A4.2 1 A4.2 2 A4.1 2 A4.1 1 A4.1 1 A4.1 3 A4.1 3 A4.1 4 A4.1 4 A4.1 2 A4.2 2 A4.2 3 A4.2 3 A4.2 2 A2.5 1 A4.6 2 A4.6 3 A4.6 4 A4.6 5 A4.6 3 A2.5 2 A2.6 3 A2.6 2" / 12"2" / 12" SLOPING DROPPED CEILING UNDER SIP ROOF PANEL SLOPING DROPPEDCEILING UNDER SIPROOF PANELFLAT DROPPED CEILING W/ STORAGE ABOVE PULL DOWN LADDER FOR ATTIC ACCESS2" / 12"8613' - 0 3/8" 8616' - 0 3/8" FLAT DROPPED CEILING W/ CONDITIONED ATTIC ABOVE CEILING HATCH FOR ATTIC ACCESS SLOPING DROPPEDCEILING UNDER SIPROOF PANELWP DROPPED CEILING NOTES: * DROPPED CEILING SHOWN WITH LIGHT GRAY SOLID HATCH. * DROPPED CEILING SET AT 9'-1" C.H. CONTRACTOR MUST VERIFY WITH MECH. DUCT COORDINATION. * LIGHT FIXTURES DIRECTLY BELOW MECH. TRUNK LINE MAY NEED TO BE SHALLOW FIXTURES OR CEILING MOUNTED FIXTURES. * DROPPED CEILING AT SIP PANELS WILL SLOPE WITH SIP AND BE COORDINATED WITH LIGHT FIXTURES AND FIRE-SPRINKLER PIPING. JS S/C6' - 6" 6' - 6"5' - 0"JSS/C6' - 4 1/4" 6' - 4 1/4" 7' - 3 1/2" 7' - 3 1/2" WP JS WP WP 3' - 0"3' - 0"4' - 0"3' - 0"4' - 0"3' - 0" GDN TO SWITCH BELOW DN TO SWITCH BELOW TO SWITCH BELOW S/CS/C S/C WP RECESSED CAN LIGHT (wet location) RECESSED CAN LIGHT (sloped ceiling fixture) RECESSED CAN LIGHT (directional spot) CEILING MOUNTED CHANDELIER RECESSED CAN LIGHT WALL MOUNTED SCONCE FIXTURE CEILING FAN UNDERCABINET LIGHT FLUORESCENT CLOSET LIGHT (JS=JAMB SWITCH) CEILING EXHAUST FAN STEP LIGHT 1/2 HOT DUPLEX OUTLET ELECTRICAL / LIGHTING LEGEND DUPLEX OUTLET RECEPTACLE SINGLE SWITCH 3-WAY SWITCH DIMMER SWITCH CEILING MOUNTED SCONCE OR PENDANT 120V UL 217 SMOKE / UL 2034 CARBON MONOXIDE COMBO M MOTION SENSOR LIGHT CEILING MOUNT RECESSED FLOOR / CEILING DUPLEX OUTLET / SPECIAL POWER SUPPY UP WALL UPLIGHTING FAN CONTROLS S/C FLUORESCENT STRIP LIGHT GFCI DUPLEX OUTLET PHONE/DATA OUTLET CABLE/COAX OUTLET OTHER NOTES * PROVIDE DOOR BELL CHIME AT EACH LEVEL. * PROVIDE POWER AT ALL HEAT TAPE AND FUTURE HEAT TAPELOCATIONS. REVIEW LOCATIONS WITH GENERAL CONTRACTOR. * ALL SWITCHES THAT CONTROL INTERIOR LIGHTS (NOT IN CLOSETS) SHOULD BE DIMMER CONTROLLED WHERE POSSIBLE AND PRACTICAL. *ALL OUTLETS AND SWITCHES SHOULD BE DECORA STYLE WITH CONCEALED SCREWS. * ALL IGNITION POINTS OF GAS FIRED MECH. EQUIP. SHALL BE 18" A.F.F. OF GARAGE (WHEN MECH IS LOCATED ADJACENT OR WITHIN THE GARAGE). LIGHTING NOTES GENERAL CONTRACTOR TO MEET 2015 IRC REQUIREMENTS SECTION N1104.1 LIGHTING EQUIPMENT: A MINIMUM OF 92 PERCENT OF THE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL BE HIGH-EFFICACY LAMPS. GFCI OUTLET PROVIDE AT ALL BATHS, KITCHENS, LAUNDRY, DISHWASHERS GARAGES, MECH. ROOMS. ARC-FAULT CIRCUIT INTERRUPTER AFCI PROTECTION IS REQUIRED ON ALL BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS, DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS, BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS, HALLWAYS, LAUNDRY AREAS, AND SIMILAR ROOMS AND AREAS. OUTDOOR RECEPTACLES ARE 125-VOLT, SINGLE PHASE, 15 AND 20 AMP AND SHALL BE GFCI. OUTLETS ARE TO HAVE A COVER AND WEATHERPROOF WHILE IN USE OT NOT 970.328.5151 OFFICEPO Box 1587, Eagle, CO 81631www.martinmanleyarchitects.comProject number Date REVISIONS8/28/2018 11:23:38 AMA6.3RCP/ELEC - UPPERJG-1831GROUSE DUPLEX PERMIT SET 8-28-188-28-18 Jarenko5128 Grouse LaneVail, CO 81657No. Description Date1/4" = 1'-0"1 3. A UPPER RCP 1/4" = 1'-0" ELECTRICAL SYMBOL LEGEND 09/17/18 09/10/2018 09/17/18 08/27/2018 09/17/18 08/27/2018 09/17/18 08/27/2018 09/17/18 09/10/2018 09/17/18 08/27/2018 09/17/18 08/27/2018 09/17/18