HomeMy WebLinkAboutB18-0374_Approved Documents_1536602855.pdf75 South Frontage Road
West,
Vail, CO 81657
Office: 970.479.2139
Inspections:
inspections@vailgov.com
Construction
B18-0374
Issued: 09/10/2018
TOWN OF VAIL
Property Information
Address: 1881 LIONS RIDGE LP 11C (210312207028 11C) ( 210312207028 )
Unit #: 11C
Parcel Number: 210312207028
Legal Description: Subdivision: VAIL POINT TOWNHOMES Lot: 11C
Contacts
Contact Type: Applicant
Full Name: Seth Williams
Address: 2330 Broadway 110 Denver, CO 80205 Phone: 3039344508
Contact Type: Applicant
Full Name: Rebecca Macmillan
Address: CO Phone: None
Contact Type: Property Owner
Full Name: DIVERSIFIED RADIOLOGY INVESTMENTS
Address: Phone: None
Contractor
Contractor Type: General
Company: Lifetime Windows & Siding
State License #: Phone: 303-934-4508
Project Information
Project Name: Diversified Radiology Investments (Unit 11C) 2018
Project Description: Remove and replace 11 windows and 2 doors U-factor .26
Fees Paid
Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$401.35
Account #: 001-0000.31123.00 - Building Plan Review Fee Fee Amount:$260.88
Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$310.00
Account #: 001-0000.31128.00 - Will Call Fee (Building Scope)Fee Amount:$5.00
Total Paid:$977.23
Conditions
CONDITIONS UNDER WHICH PERMITS BECOME VOID:
If construction is not begun within 6 months from the date permit was issued.
If more than 5 months elapses between inspections.
If incorrect information is given on the application at the time the permit was issued.
Christopher Jarecki - Town of Vail Building Official
NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal
law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees.
PERMIT FEE RECEIPT
Case # B18-0374
Date Printed: 08/28/2018
TOWN OF VAIL - FEES RECEIPT
Permit Summary
Case Number: B18-0374 Status: Created
Permit Number: Date Started: 08/28/2018
Permit Type: Construction Subcases Multi-Family
Lot Number: 1
Property: 1881 LIONS RIDGE LP 11C (210312207028 11C) (210312207028)
Contacts
Contact Type: Applicant
Company Name: Lifetime Windows And Siding
Full Name: Rebecca Macmillan
Address: CO
Email: rebecca@lifetimewindowscolorado.com
Contact Type: Applicant
Company Name: Lifetime Windows and Siding
Full Name: Seth Williams
Address: 2330 Broadway 110 Denver, CO 80205
Email: Seth@Lifetimewindowscolorado.com
Contact Type: Property Owner
Full Name: DIVERSIFIED RADIOLOGY INVESTMENTS
Address:
Permit Fees
Fee Information Account Amount
Permit Fee 001-0000.31111.00 $401.35
Plan Review 001-0000.31123.00 $260.88
Construction Tax 110-0000.31060.00 $310.00
Will Call Fee 001-0000.31128.00 $5.00
Payment Information Date Paid Payment Type Amount
Will Call Fee 08/28/2018 Credit Card $5.00
Paid By: - Notes: mc-peter svedin
Construction Tax 08/28/2018 Credit Card $310.00
Paid By: - Notes: mc-peter svedin
Plan Review 08/28/2018 Credit Card $260.88
Paid By: - Notes: mc-peter svedin
Permit Fee 08/28/2018 Credit Card $401.35
Paid By: - Notes: mc-peter svedin
FEE TOTAL $977.23
AMOUNT PAID $977.23
BALANCE DUE $0.00
08/28/2018 - 3:09:12 PM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657
1 / 1
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 1 of 11
UNIT SUMMARY
The following is a schedule of the windows and doors for this project. For additional unit details, please see Line Item
Quotes.
Additional charges, tax or Terms and Conditions may apply. Detail pricing is per unit.
NUMBER OF LINES: 13 TOTAL UNIT QTY: 41
LINE MARK UNIT BRAND ITEM QTY
1 DINING Infinity Inswing French Door
CN 6065
RO 72" X 80"
Entered as
CN 6065
1
2 BED 3 Infinity Sliding Patio Door
CN 5065
RO 60" X 80"
Entered as
CN 5065
1
3 FOYER Infinity Casement Picture
RO 33 1/2" X 58 7/8"
Entered as
FS 32 1/2" X 58 3/8"
1
4 FOYER Infinity Infinity Assembly
RO 66 1/4" X 59 1/4"
Entered as
FS 65 1/4" X 58 3/4"
1
5 BED 2 Infinity Infinity Assembly
RO 99 1/4" X 47"
Entered as
FS 98 1/4" X 46 1/2"
1
6 MASTER Infinity Infinity Assembly
RO 99" X 59"
Entered as
FS 98" X 58 1/2"
1
7 M.BATH Infinity Awning
RO 47 1/2" X 29"
Entered as
FS 46 1/2" X 28 1/2"
1
8 MASTER Infinity Infinity Assembly
RO 99" X 59"
Entered as
FS 98" X 58 1/2"
1
9 MASTER Infinity Infinity Assembly
RO 66 1/4" X 59"
Entered as
FS 65 1/4" X 58 1/2"
1
10 DINING Infinity Infinity Assembly
RO 99" X 59"
Entered as
FS 98" X 58 1/2"
2
11 LIV Infinity Casement
RO 33 5/8" X 59"
Entered as
FS 32 5/8" X 58 1/2"
1
12 LIV Infinity Casement Picture
RO 33 5/8" X 59"
Entered as
FS 32 5/8" X 58 1/2"
1
13 Infinity Parts: 171299 V1191 INT FRAME COVER 120"
PC - STONE WHITE
28
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 2 of 11
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 3 of 11
LINE ITEM QUOTES
The following is a schedule of the windows and doors for this project. For additional unit details, please see Line Item
Quotes. Additional charges, tax or Terms and Conditions may apply. Detail pricing is per unit.
Line #1
Qty: 1
Mark Unit: DINING
Entered As: CN
FS 71" X 79 1/2"
Egress Information
Width: 31 15/64" Height: 74 15/16"
Net Clear Opening: 16.25 SqFt
Performance Information
U-Factor: 0.3
Solar Heat Gain Coefficient: 0.18
Visible Light Transmittance: 0.42
Condensation Resistance: 58
CPD Number: MAR-N-438-00003-00001
ENERGY STAR: N, NC, SC, S
Bronze Exterior
Stone White Interior
Infinity Inswing French Door - OX Left Hand
CN 6065
Rough Opening 72" X 80"
Left Panel
IG - 1 Lite
Tempered Low E3
Capillary Tube
Right Panel
IG - 1 Lite
Tempered Low E3
Capillary Tube
Multi-Point Lock
Classic White Interior Primary Handle Set
Classic Oil Rubbed Bronze PVD Keyed Exterior Primary Handle Set
Keyed Alike
Keyed Alike Group 1
White Adjustable Hinges
Sliding Screen
Bronze Surround
Charcoal Fiberglass Mesh
***Screen/Combo Ship Loose
Bronze Sill
6 9/16" Jambs
Thru Jamb Installation
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #2
Qty: 1
Mark Unit: BED 3
Entered As: CN
FS 59" X 79 1/2"
Bronze Exterior
Stone White Interior
Infinity Sliding Patio Door
OX
CN 5065
Rough Opening 60" X 80"
Left Panel
IG - 1 Lite
Tempered Low E3
Capillary Tube
Right Panel
IG - 1 Lite
Tempered Low E3
Capillary Tube
Multi-Point Lock
White Interior Handle
Oil Rubbed Bronze PVD Keyed Exterior Handle
Keyed Alike
Keyed Alike Group 1
Sliding Screen
Bronze Surround
Charcoal Fiberglass Mesh
***Screen/Combo Ship Loose
Bronze Sill
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 4 of 11
Egress Information
Width: 23 17/64" Height: 74 47/64"
Net Clear Opening: 12.08 SqFt
Performance Information
U-Factor: 0.31
Solar Heat Gain Coefficient: 0.23
Visible Light Transmittance: 0.52
Condensation Resistance: 54
CPD Number: MAR-N-373-00475-00001
Black Weather Strip
4 9/16" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #3
Qty: 1
Mark Unit: FOYER
Entered As: FS
FS 32 1/2" X 58 3/8"
Egress Information
No Egress Information available.
Performance Information
U-Factor: 0.25
Solar Heat Gain Coefficient: 0.22
Visible Light Transmittance: 0.51
Condensation Resistance: 43
CPD Number: MAR-N-311-00919-00001
ENERGY STAR: N, NC, SC, S
Bronze Exterior
Stone White Interior
Infinity Casement Picture
Frame Size 32 1/2" X 58 3/8"
Rough Opening 33 1/2" X 58 7/8"
IG - 1 Lite
Tempered Low E3/ERS
Capillary Tube
Black Weather Strip
2 1/4" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #4
Qty: 1
Mark Unit: FOYER
Entered As: FS
Bronze Exterior
Stone White Interior
2W1H - Rectangle Assembly
Assembly Frame Size
65 1/4" X 58 3/4"
Assembly Rough Opening
66 1/4" X 59 1/4"
Unit: A1
Infinity Casement - Left Hand
Basic Frame 32 5/8" X 58 3/4"
Rough Opening 33 5/8" X 59 1/4"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Fiberglass Mesh
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 5 of 11
FS 65 1/4" X 58 3/4"
Egress Information A1, A2
Width: 22 17/64" Height: 53 15/16"
Net Clear Opening: 8.34 SqFt
Performance Information A1, A2
U-Factor: 0.26
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.45
Condensation Resistance: 43
CPD Number: MAR-N-309-00863-00001
ENERGY STAR: N, NC, SC, S
Unit: A2
Infinity Casement - Right Hand
Basic Frame 32 5/8" X 58 3/4"
Rough Opening 33 5/8" X 59 1/4"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Fiberglass Mesh
2 1/4" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #5
Qty: 1
Mark Unit: BED 2
Entered As: FS
FS 98 1/4" X 46 1/2"
Egress Information A1, A3
Width: 22 25/64" Height: 41 11/16"
Net Clear Opening: 6.48 SqFt
Egress Information A2
No Egress Information available.
Performance Information A1, A3
U-Factor: 0.26
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.45
Condensation Resistance: 43
CPD Number: MAR-N-309-00863-00001
ENERGY STAR: N, NC, SC, S
Performance Information A2
U-Factor: 0.25
Solar Heat Gain Coefficient: 0.22
Visible Light Transmittance: 0.51
Condensation Resistance: 43
CPD Number: MAR-N-311-00919-00001
ENERGY STAR: N, NC, SC, S
Bronze Exterior
Stone White Interior
3W1H - Rectangle Assembly
Assembly Frame Size
98 1/4" X 46 1/2"
Assembly Rough Opening
99 1/4" X 47"
Unit: A1
Infinity Casement - Left Hand
Basic Frame 32 3/4" X 46 1/2"
Rough Opening 33 3/4" X 47"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Fiberglass Mesh
Unit: A2
Infinity Casement Picture
Basic Frame 32 3/4" X 46 1/2"
Rough Opening 33 3/4" X 47"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
Unit: A3
Infinity Casement - Right Hand
Basic Frame 32 3/4" X 46 1/2"
Rough Opening 33 3/4" X 47"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Fiberglass Mesh
2 1/4" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #6 Mark Unit: MASTER
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 6 of 11
Qty: 1
Entered As: FS
FS 98" X 58 1/2"
Egress Information A1, A3
Width: 22 5/16" Height: 53 11/16"
Net Clear Opening: 8.32 SqFt
Egress Information A2
No Egress Information available.
Performance Information A1, A3
U-Factor: 0.26
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.45
Condensation Resistance: 43
CPD Number: MAR-N-309-00863-00001
ENERGY STAR: N, NC, SC, S
Performance Information A2
U-Factor: 0.25
Solar Heat Gain Coefficient: 0.22
Visible Light Transmittance: 0.51
Condensation Resistance: 43
CPD Number: MAR-N-311-00919-00001
ENERGY STAR: N, NC, SC, S
Bronze Exterior
Stone White Interior
3W1H - Rectangle Assembly
Assembly Frame Size
98" X 58 1/2"
Assembly Rough Opening
99" X 59"
Unit: A1
Infinity Casement - Left Hand
Basic Frame 32 43/64" X 58 1/2"
Rough Opening 33 43/64" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Hi-Transparency Fbrgls Mesh
Unit: A2
Infinity Casement Picture
Basic Frame 32 43/64" X 58 1/2"
Rough Opening 33 43/64" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
Unit: A3
Infinity Casement - Right Hand
Basic Frame 32 43/64" X 58 1/2"
Rough Opening 33 43/64" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Hi-Transparency Fbrgls Mesh
2 1/4" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #7
Qty: 1
Mark Unit: M.BATH
Entered As: FS
FS 46 1/2" X 28 1/2"
Egress Information
No Egress Information available.
Bronze Exterior
Stone White Interior
Infinity Awning - Roto Operating
Frame Size 46 1/2" X 28 1/2"
Rough Opening 47 1/2" X 29"
IG - 1 Lite
Tempered Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Interior Full Screen
Stone White Surround
Charcoal Fiberglass Mesh
2 1/4" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 7 of 11
Performance Information
U-Factor: 0.27
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.45
Condensation Resistance: 42
CPD Number: MAR-N-310-01079-00001
ENERGY STAR: N, NC, SC, S
Line #8
Qty: 1
Mark Unit: MASTER
Entered As: FS
FS 98" X 58 1/2"
Egress Information A1, A3
Width: 22 5/16" Height: 53 11/16"
Net Clear Opening: 8.32 SqFt
Egress Information A2
No Egress Information available.
Performance Information A1, A3
U-Factor: 0.26
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.45
Condensation Resistance: 43
CPD Number: MAR-N-309-00863-00001
ENERGY STAR: N, NC, SC, S
Performance Information A2
U-Factor: 0.25
Solar Heat Gain Coefficient: 0.22
Visible Light Transmittance: 0.51
Condensation Resistance: 43
CPD Number: MAR-N-311-00919-00001
ENERGY STAR: N, NC, SC, S
Bronze Exterior
Stone White Interior
3W1H - Rectangle Assembly
Assembly Frame Size
98" X 58 1/2"
Assembly Rough Opening
99" X 59"
Unit: A1
Infinity Casement - Left Hand
Basic Frame 32 43/64" X 58 1/2"
Rough Opening 33 43/64" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Hi-Transparency Fbrgls Mesh
Unit: A2
Infinity Casement Picture
Basic Frame 32 43/64" X 58 1/2"
Rough Opening 33 43/64" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
Unit: A3
Infinity Casement - Right Hand
Basic Frame 32 43/64" X 58 1/2"
Rough Opening 33 43/64" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Hi-Transparency Fbrgls Mesh
2 1/4" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #9
Qty: 1
Mark Unit: MASTER
Bronze Exterior
Stone White Interior
2W1H - Rectangle Assembly
Assembly Frame Size
65 1/4" X 58 1/2"
Assembly Rough Opening
66 1/4" X 59"
Unit: A1
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 8 of 11
Entered As: FS
FS 65 1/4" X 58 1/2"
Egress Information A1, A2
Width: 22 17/64" Height: 53 11/16"
Net Clear Opening: 8.30 SqFt
Performance Information A1, A2
U-Factor: 0.26
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.45
Condensation Resistance: 43
CPD Number: MAR-N-309-00863-00001
ENERGY STAR: N, NC, SC, S
Infinity Casement - Left Hand
Basic Frame 32 5/8" X 58 1/2"
Rough Opening 33 5/8" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Hi-Transparency Fbrgls Mesh
Unit: A2
Infinity Casement - Right Hand
Basic Frame 32 5/8" X 58 1/2"
Rough Opening 33 5/8" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Hi-Transparency Fbrgls Mesh
2 1/4" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #10
Qty: 2
Mark Unit: DINING
Entered As: FS
FS 98" X 58 1/2"
Egress Information A1, A3
Width: 22 5/16" Height: 53 11/16"
Net Clear Opening: 8.32 SqFt
Egress Information A2
No Egress Information available.
Performance Information A1, A3
U-Factor: 0.26
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.45
Condensation Resistance: 43
CPD Number: MAR-N-309-00863-00001
ENERGY STAR: N, NC, SC, S
Performance Information A2
U-Factor: 0.25
Solar Heat Gain Coefficient: 0.22
Visible Light Transmittance: 0.51
Condensation Resistance: 43
CPD Number: MAR-N-311-00919-00001
ENERGY STAR: N, NC, SC, S
Bronze Exterior
Stone White Interior
3W1H - Rectangle Assembly
Assembly Frame Size
98" X 58 1/2"
Assembly Rough Opening
99" X 59"
Unit: A1
Infinity Casement - Left Hand
Basic Frame 32 43/64" X 58 1/2"
Rough Opening 33 43/64" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Hi-Transparency Fbrgls Mesh
Unit: A2
Infinity Casement Picture
Basic Frame 32 43/64" X 58 1/2"
Rough Opening 33 43/64" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
Unit: A3
Infinity Casement - Right Hand
Basic Frame 32 43/64" X 58 1/2"
Rough Opening 33 43/64" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 9 of 11
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Hi-Transparency Fbrgls Mesh
2 1/4" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #11
Qty: 1
Mark Unit: LIV
Entered As: FS
FS 32 5/8" X 58 1/2"
Egress Information
Width: 22 17/64" Height: 53 11/16"
Net Clear Opening: 8.30 SqFt
Performance Information
U-Factor: 0.26
Solar Heat Gain Coefficient: 0.2
Visible Light Transmittance: 0.45
Condensation Resistance: 43
CPD Number: MAR-N-309-00863-00001
ENERGY STAR: N, NC, SC, S
Bronze Exterior
Stone White Interior
Infinity Casement - Left Hand
Frame Size 32 5/8" X 58 1/2"
Rough Opening 33 5/8" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
White Folding Handle
Easy Wash Hinges
Interior Full Screen
Stone White Surround
Charcoal Hi-Transparency Fbrgls Mesh
2 1/4" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
Line #12
Qty: 1
Mark Unit: LIV
Bronze Exterior
Stone White Interior
Infinity Casement Picture
Frame Size 32 5/8" X 58 1/2"
Rough Opening 33 5/8" X 59"
IG - 1 Lite
Low E3/ERS
Capillary Tube
Black Weather Strip
2 1/4" Jambs
No Installation Method
***Note: Capillary tubes will be added to ALL Low E glass types without Argon.
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 10 of 11
Entered As: FS
FS 32 5/8" X 58 1/2"
Egress Information
No Egress Information available.
Performance Information
U-Factor: 0.25
Solar Heat Gain Coefficient: 0.22
Visible Light Transmittance: 0.51
Condensation Resistance: 43
CPD Number: MAR-N-311-00919-00001
ENERGY STAR: N, NC, SC, S
Line #13
Qty: 28
Mark Unit:
Infinity Parts
171299 V1191 INT FRAME COVER 120" PC - STONE WHITE
OMS Ver. 0002.21.00 (Current)
Product availability and pricing subject to change.
Dealer PO Number: W13121WENZ
W13121WENZ
W13121WENZ
Quote Number: R62N5ES
Architectural Project Number:
OMS Ver. 0002.21.00 (Current) Processed on: 7/25/2018 1:53:32 PM Page 11 of 11
Product and Performance Information
NFRC energy ratings and values may vary depending on the exact configuration of glass thickness used on the unit. This
data may change over time due to ongoing product changes or updated test results or requirements.
The National Fenestration Rating Council (NFRC) has developed and operates a uniform national rating system for the
energy performance of fenestration products, including windows and doors. For additional information regarding this
rating system, see www.nfrc.org/WindowRatings.
NFRC energy values and ratings may change over time due to ongoing product changes, updated test results or
requirements.
MEMORANDUM
To: Vail Point Townhome Associa:on Board
From: Mauriello Planning Group
Subject: Wenzel Residence, Vail Point #11 and #25
Contractor: Dee Baumgartner
Date: July 12, 2018
Overview:
The applicant is proposing window replacement. Windows are fiberglass and the color is bronze, which are to
match the dark bronze color on other more recent windows in the complex. The detailing, including the width
of window and slider door frames, shall match the exis:ng windows and slider doors. No change in window
sizes or loca:on. The finished product shall appear with no evidence that the exterior of building has been
modified and all stucco repairs and/or necessary pain:ng is solely the responsibility of the applicant.
Process:
Step 1: MPG (as administrator) reviews applica:on for compliance with Design Guidelines, establishes fees
and deposit requirement, requires compliance agreement, then forwards recommenda:on to Board.
Step 2: Board reviews applica:on, takes final ac:on.
Analysis:
Based on the informa:on provided, the window replacement complies with the Design Guidelines. The Design
Guidelines will be amended to allow Fiberglass and Composite windows and slider doors. MPG would
recommend approval of the window replacement.
• Applica:on Fee Recommended: $700 ($350 per unit)
• Compliance Deposit Recommended: $1,000 ($500 per unit)
• Compliance Agreement Recommended: Yes
Va il Point Townhomes Submit to Mauriello Planning Group
Via email: Allison@mpgvoil.com
Via moil: PO Box 4777, Eagle, CO 8163l
Design Review Application Form Ph. 970.390.8530
NAME OF PROJ ECT: We.nz,e.. I UNIT NO: I I c 2_,S-
·
Gpneral Description of the Project:
' ·.+
(.,+o S (,/ee,.( ..') -j o
l ,) , I \ kl e L,,·. ,1 l
Owner Name:
Mailing Address:
Phone: 3g3-9a;- t 5"f7
Owner Signature: _ ____________ ___ _ Date:
I acknowledge that I am aware and will comply with the rules and regulations as set forth in the Vail Point
Townhomes Design Guidelines and Covenants. I authorize the representative below to act on my behalf and
recognize that failure to abide by the rules and regulations by either my representative or myself may result in
fines.
Applicant/Represen!:1tive Name: *e_
8sv bj ~·✓-t ...-..Q
v-
Mailing Address: 00 8 / lJ '78 ;pt LJc.<,;,{M ,..,;sJ<e-.,- < 0 B OQ,3/
Phone: .Jo3 - 5" l.3 · ) 87 / Email: Jee e l,fe.-f, ~<cs, t"'da ..,.,sCc../ca,.-r,do, c.o ""'-
Architect Name: License#:
Ma iling Address:Phone: _ _ _ _ _ _ _ _ _ _ _ _ Email:
Contractor Na me: / ,J?e-J:,""'C I"' 1c~ 5 c..~e/. :Sdd cense#:
Mailing Address: 2330 81'cad (>- __ , __ 1_ f/D
Phone: 3a3 - 93'1· 3/S08 Email: L {'c:::..t,..-is;.W 111\, e, 0 t:1-~, /, C Cl M
7/5/18
1.
2.
3.
4.
5.
6.
7.
8.
9.
Diversified Radiology Investments, Inc
Shareholders
(6.1.18)
(current holdings: VailPoint Townhomes, #1 JCand#25)
Lawrence Emmons, MD
7290S. Andes Court
Centennial, CO 80016
lemmons@divrad.com
Alexandra Fortner, MD
2327 S. Juniper Way
Lakewood, CO80228
afortner@diwad.com
Garret Gannuch, MD
30Coral Place
Greenwood Village, CO 80111
ggannuch@divrad.com
Stephen George, MD
61 Golden Eagle Lane
Littleton, CO 80127
sgeorge@divrad.com
John Gerhold, MD
5031 Sanford Circle West
Englewood, CO 80113
Robert Johnston, MD
10037 MatthewLane
Highlands Ranch, CO 80130
rjohnston@divrad.com
Jennifer Kemp, MD
3430E. Kentucky Ave
Denver, CO 80209
jkemp@divrad.com
Kim McMillin, MD
734 Evening Star Court
Castle Pines Village
Castle Rock, CO 80108
kmcmillin@divrad.com
Hari Reddy, MD
1650Wewatta St #1805
Denver, CO 80202
hredd:t(a)divrad.com
10. Eric Robbins, MD
400Dahlia
Denver, CO 80220
erobbins@divrad.com
11. John Roth, MD
1693 Montain Drive East
Golden, CO 80401
jroth@divrad.com
12. Wayne Wenzel, MD
41 Silverfox Circle
Greenwood Village, CO 80121
wwenzel@divrad.com