Loading...
HomeMy WebLinkAboutDRB18-0315_Approved Plans_1536260896.pdf1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.00 COVERGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET OWNER: GOLDEN PEAK ENTERPRISES LLC. 814 POTATO PATCH DR VAIL, CO 81657 ARCHITECT: BILL PIERCE, PRINCIPAL IN CHARGE PIERCE ARCHITECTS 1650 E. VAIL VALLEY DRIVE, C1 VAIL, COLORADO 81657 P: 970.476.6342 F: 970.476.4901 E: bill@vailarchitects.com CONSULTANTS: AEC - ARCHITECTURAL ENGINEERING CONSULTANTS Avon, CO 81620 40801 US-6 #214 P: 970.748.8520 R & H MECHANICAL 825 CHAMBERS AVE. EAGLE, CO. 81631 P: 970.328.2699 CONTRACTOR: MEADOW MOUNTAIN HOMES RE: SEAN McGINLEY PO Box 1977 PO Box 1977 Edwards, Colorado 81632 P: 970.926.2824 M: E sean@meadowmountainhomes.com STRUCTURAL ENGINEER: KRM CONSULTANTS 101 Eagle Rd. 2nd floor Avon, CO 81620 Avon, CO 81620 P: 970.949.9391 E: tim@krmconsultants.com OWNER'S REP REID PHILLIPS P: E: REIDPHILLIPS@HOTMAIL.COM ADMINISTRATIVE INFO. BUILDING CODE SUMMARY PROJECT DIRECTORY BUILDING CODE: 2015 IBC CONSTRUCTION TYPE: TYPE V-A DWELLING UNITS: 2 OCCUPANCY TYPE R-3 SEPERATE SPRINKLE SYSTEMS TO BE INSTALLED PER UNIT AS PER VF AND ES STANDARDS LEGAL DESCRIPTION OF PROPERTY: Situs Address 000814 POTATO PATCH DR Tax Area SC103 - VAIL (TOWN) - SC103 Parcel Number 2101-63-01-012 Legal Summary Subdivision: VAIL POTATO PATCH Block: 1 Lot: 3 BK-0234 PG-0538 BK-0275 PG-0401 814 POTATO PATCH DR VAIL, CO 81657 PROJECT LOCATION LOT 814    DRB APPROVED 9/5/2018 12:00:00 AM ° ±  W/ < ROUND WITH DEGREES PLUS OR MINUS PROPERTY LINE ANGLE CENTER LINE Room name 101 ELEVATION A101 1 SIM 100'-0" SPOT ELEVATION 1 A101 SIM DETAIL NUMBER SHEET WHERE SHOWN SECTION LETTER SHEET WHERE SHOWN DETAIL DESIGNATOR BUILDING SECTION DESIGNATOR 1 101 DOOR DESIGNATOR 1i WINDOW DESIGNATOR 0 GRID LINE 1i WALL TYPE 1 REVISION NUMBER LEVEL INDICATOR NAME INTERIOR ELEVATION DESIGNATOR A601 1 ELEVATION NUMBER SHEET NUMBER DOOR NUMBER ROOM NUMBER ROOM NUMBER EXTERIOR ELEVATION DESIGNATOR A301 1 ELEVATION NUMBER SHEET NUMBER 00 00 00 CONSTRUCTION SPECIFICATION INSTITUTE SECTION NUMBER - REFER TO PROJECT MANUAL FOR PRODUCT SPECIFICATION 4' - 5" FACE OF STRUCTURE TO FACE OF STRUCTURE OR EXISTING FINISH N PROJECT NORTH 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.01 SHEET INDEXGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET SHEET INDEX SHEET # DESCRIPTION BY ISSUE DATE SHEET INDEX SHEET # DESCRIPTION BY ISSUE DATE GENERAL A0.00 COVER PIERCE ARCHITECTS 7/16/2018 CIVIL T.01 TOPOGRAPHICAL SURVEY PEAKLAND 7/16/2018 ARCHITECTURAL A0.01 SHEET INDEX PIERCE ARCHITECTS 7/16/2018 A0.03 EXTERIOR MATERIALS PIERCE ARCHITECTS 7/16/2018 A0.04a GRFA STUDY PIERCE ARCHITECTS 7/16/2018 A0.06 SITE PLAN PIERCE ARCHITECTS 7/16/2018 A0.07 LANDSCAPE PLAN PIERCE ARCHITECTS 7/16/2018 A0.08 TREE REMOVAL PLAN PIERCE ARCHITECTS 7/16/2018 A0.09 GRADING PLAN PIERCE ARCHITECTS 7/16/2018 A0.10 P.E.C. REQUIREMENTS PIERCE ARCHITECTS 7/16/2018 A0.11 ASSEMBLIES PIERCE ARCHITECTS 7/16/2018 A0.13 SITE DISTURBANCE CALC. PIERCE ARCHITECTS 7/16/2018 A1.00 ROOF PLAN PIERCE ARCHITECTS 7/16/2018 A1.00a ORIGINAL GRADE PIERCE ARCHITECTS 7/16/2018 A1.01 1ST LEVEL PIERCE ARCHITECTS 7/16/2018 A1.02 2ND LEVEL PIERCE ARCHITECTS 7/16/2018 A1.03 3RD LEVEL PIERCE ARCHITECTS 7/16/2018 A1.04 4TH LEVEL PIERCE ARCHITECTS 7/16/2018 A1.11 1ST LEVEL RCP PIERCE ARCHITECTS 7/16/2018 A1.12 2ND LEVEL RCP PIERCE ARCHITECTS 7/16/2018 A1.13 3RD LEVEL RCP PIERCE ARCHITECTS 7/16/2018 A1.14 4TH LEVEL RCP PIERCE ARCHITECTS 7/16/2018 A1.21 1ST LEVEL FRAMING PIERCE ARCHITECTS 7/16/2018 A1.22 2ND LEVEL FRAMING PIERCE ARCHITECTS 7/16/2018 A1.24 4TH LEVEL FRAMING PIERCE ARCHITECTS 7/16/2018 A2.01 SOUTH ELEVATION PIERCE ARCHITECTS 7/16/2018 A2.02 EAST ELEVATION PIERCE ARCHITECTS 7/16/2018 A2.03 NORTH ELEVATION PIERCE ARCHITECTS 7/16/2018 A2.04 WEST ELEVATION PIERCE ARCHITECTS 7/16/2018 A5.21 LIGHT DETAILS / CUT SHEETS PIERCE ARCHITECTS 7/16/2018 A6.01 DOOR SCHEDULE PIERCE ARCHITECTS TBD A6.03 WINDOW SCHEDULE PIERCE ARCHITECTS TBD A9.01 3D MODEL PIERCE ARCHITECTS 7/16/2018 A9.02 3D MODEL PIERCE ARCHITECTS 7/16/2018 A9.03 3D MODEL PIERCE ARCHITECTS 7/16/2018 A9.04 3D MODEL PIERCE ARCHITECTS 7/16/2018 STRUCTURAL S1 NOTES KRM TBD S2a FOUNDATION PLAN KRM TBD S2b FOUNDATION PLAN KRM TBD S3 SECOND LEVEL FRAMING PLAN KRM TBD S4 THIRD LEVEL/LOW ROOF KRM TBD S5 FORTH LEVEL/MID ROOF KRM TBD S6 HIGH ROOF FRAMING PLAN KRM TBD S7 DETAILS KRM TBD MECHANICAL M0.00 MECH. ELECTRICAL E0.00 ELEC. PLUMBING P0.00 PLUMB. DRAWING CONVENTIONS MISC. ABBREVIATIONS SHEET SETS    DRB APPROVED 9/5/2018 12:00:00 AM EXTERIOR MATERIALS SEE KEYNOTES @ ELEVATIONS FOR LOCATIONS COPPER - GUTTERS AND DOWNSPOUTS - FLASHING - PROVIDED BY GC SURFACE STONE - SCHIST - PATIOS AND ENTRY - PROVIDED BY GALLEGOS WOOD SIDING VENEER - RUSTIC WOOD SIDING - 1X6 WIDTH - GOLDEN BROWN/GREY MIX METAL SEAM ROOFPORCELANOSA TILE - FERROKER - FIREPLACES AND GARAGE PAINTED STEEL COMPONENTS - STEEL SUPPORTS - DECK BRACKETS WHITE STUCCO - WHITE - STUCCO - BLACK - TYPICAL 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.03 EXTERIOR MATERIALSGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET 1 3D - EXTERIOR MATERIALS (VIEW LOOKING NORTH) 2 3D - EXTERIOR MATERIALS (VIEW LOOKING SOUTH) DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM UP UP UP UP UP UP UP UP 689 SF GARAGE 2373 SF -600 SF GARAGE 1773 TOTAL 2373 SF EXISTING 2017 SF EXISTING 2,110 SF TOTAL 93 SF PROPOSED 1802 SF EXISTING 1812 SF TOTAL 10 SF PROPOSED 578 SF EXISTING 297 SF PROPOSED 875 SF TOTAL 2,461 SF SITE COVERAGE FOOTPRINT AND ROOF COVER > 4FT TOTAL AVAILABLE GRFA GRFA RATIO SITE AREA 10,000 SF X .46 = 4600 SF 5,000 SF X .38 = 1900 SF 2,323 SF X .13 = 302 SF 6,802 SF MAX GRFA 0.46 of site area ≤ 10,000 sq. ft., plus 0.38 of site area > 10,000 and ≤ 15,000 sq. ft., plus 0.13 of site area > 15,000 and ≤ 30,000 sq. ft., plus 0.06 of site area > 30,000 sq. ft. 17,323 SF (.3977 ACRES) MAX GRFA AVAILABLE MAX SITE COVERAGE 20% OF TOTAL SITE 17,323 SF X .2 = 3,465 SF TOTAL SQUARE FOOTAGE TOTAL SF 2,110 SQ FT GARAGE LEVEL 2,373 SQ FT 1,812 SQ FT 875 SQ FT 7,170 SQ FT TOTAL EXISTING SQUARE FOOTAGE TOTAL DEDUCTIONS 2,373 SQ FT 17 SQ FT TOTAL GRFA 2ND LEVEL 3RD LEVEL 4TH LEVEL TOTAL SF GARAGE LEVEL 2ND LEVEL 3RD LEVEL 4TH LEVEL TOTAL SF GARAGE LEVEL TOTAL SF GARAGE LEVEL 2ND LEVEL 3RD LEVEL 4TH LEVEL 2,017 SQ FT 2,373 SQ FT 1,802 SQ FT 578 SQ FT 6,770 SQ FT * SQFT INCLUDING GARAGES, BASEMENTS, CRAWLSPACES, ATTICS, ETC. * SQFT OF GARAGES, BASEMENTS, CRAWLSPACES, ATTICS, ETC. TO BE SUBTRACTED FOR GRFA CALC. * TOTAL SQFT WITH GARAGE AREA AND BASEMENT AREA SUBTRACTED DEDUCTIONS - GARAGE 600 SQ FT 600 SQ FTTOTAL SF GARAGE LEVEL DEDUCTIONS - BASEMENT 2,373 SQ FT 617 SQ FTTOTAL SF GARAGE LEVEL 2,373 SF X .26 EXPOSED 617 SF EXPOSED 1,756 SF UNEXPOSED 300 SF X 2 SPACES 600 SF GARAGE 2,373 SF BASEMENT X 26% EXPOSED = 617 SF 617 SF - 600 SF GARAGE CREDIT = 17 SF 17 SF 2,110 SF 1,812 SF 875 SF 4,814 SF PROPOSED GRFA PROPOSED SITE COVERAGE 2,461 SF TOTAL EXISTING GRFA TOTAL SF GARAGE LEVEL 2ND LEVEL 3RD LEVEL 4TH LEVEL 17 SQ FT 2,017 SQ FT 1,802 SQ FT 578 SQ FT 4,414 SQ FT TOTAL PROPOSED GRFA TOTAL SF GARAGE LEVEL 2ND LEVEL 3RD LEVEL 4TH LEVEL 0 SQ FT 93 SQ FT 10 SQ FT 297 SQ FT 400 SQ FT * UPDATED 6.26.18 4,814 SF BASEMENT FULLY UNDERGROUND * REFER TO PROPOSD SITE FOR TOPOGRAPHY REFERENCES BASEMENT 1/2 UNDERGROUND 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.04a GRFA STUDYGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165708/02/2018 PRE- PERMIT SET NORTH 1" = 10'-0"1 814 GARAGE - GRFA 1" = 10'-0"2 814 SECOND LEVEL - GRFA 1" = 10'-0"3 814 THIRD LEVEL- GRFA 1" = 10'-0"4 814 FOURTH LEVEL (OFFICE) - GRFA 1" = 20'-0" 5 814 PPD - SITE COVERAGE 1/8" = 1'-0" GRFA CALC DATE NO. DESCRIPTION 1" = 10'-0"6 GRFA BASEMENT CALC DIAGRAM DRB APPROVED 9/5/2018 12:00:00 AM 189.61 SF 23.91 SF 382.98 SF 261.94 SF 64.49 SF 154.78 SF 93.54 SF 245.61 SF 245.61 SF 8666' 8668' 8670' 8672' 8674' 8676'7'-11 5/8"189.61 SF 23.91 SF 382.98 SF 239.26 SF 42.17 SF WALL 1 WALL 2 WALL 3 WALL 4 WALL 5 WALL 7 WALL 8 WALL 9 WALL 6 23'-9 17/32" 3'-0" 32'-2" 22'-0" 5'-5" 13'-0" 154.73 SF WALL 10 8664' 8662' 8660' 8674' 8" F.F. @ SECOND LEVEL 8661' 4" F.F. @ GARAGE LEVEL 8666' 8668' 8670' 8672' 8674' 8676' 8664' 8662' 8660' 128.28 SF 7'-10 71/256" 20'-7 35/64" 20'-7 35/64" 19'-5" 5'-0" 8666' 8668' 8670' 8672' 8674' 8676' 8664' 8662' 8660' 15'-0" 15'-0" 10'-0" 18'-0" 39.84 SF WALL 11 39.84 SF 119.53 SF WALL 12 119.53 SF WALL 13 119.53 SF 79.69 SF WALL 14 79.69 SF 143.44 SF WALL 15 143.44 SF 8665' 3 1/4" F.F. @ ENTRY LEVEL 62.20 SF 8673' 2 7/8" B.O. STRUCTURE @ SECOND LEVEL 8674' 8" F.F. @ SECOND LEVEL 8661' 4" F.F. @ GARAGE LEVEL 8665' 3 1/4" F.F. @ ENTRY LEVEL 8673' 2 7/8" B.O. STRUCTURE @ SECOND LEVEL 8674' 8" F.F. @ SECOND LEVEL 8661' 4" F.F. @ GARAGE LEVEL 8665' 3 1/4" F.F. @ ENTRY LEVEL 8673' 2 7/8" B.O. STRUCTURE @ SECOND LEVEL TOTAL WALL SF 189.61 23.91 382.98 261.94 64.49 154.78 93.54 245.61 245.61 154.73 39.84 119.53 119.53 79.69 + 143.44 2319.23 SF TOTAL UNEXPOSED WALL SF 189.61 23.91 382.98 239.26 42.17 62.20 0.00 0.00 128.28 139.44 39.84 119.53 119.53 79.69 + 143.44 1709.88 SF TOTAL EXPOSED WALL SF 2319.23 - 1709.88 609.35 SF EXPOSED WALL % 609.35 / 2319.23 26% EXPOSED 119.53 SF 139.44 SF * REFER TO PROPOSD SITE FOR TOPOGRAPHY REFERENCES WALL1 WALL 2 WALL 3 WALL4 WALL 5 WALL 6 WALL 7 WALL 8WALL 9 WALL 10 WALL 11 WALL 12 WALL 13 WALL 14 WALL 15 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.04b GRFA BASEMENT CALCGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 PRE- PERMIT SET 1/4" = 1'-0"1 GRFA BASEMENT CALC DATE NO. DESCRIPTION 1/8" = 1'-0"2 GRFA BASEMENT CALC DIAGRAM Copy 1 DRB APPROVED 9/5/2018 12:00:00 AM UP HEATED CONCRETE DRIVEWAY POTATO PATCH DRIVE 131.9710% SNOWSTORAGE PROPOSED DUMPSTER LOCATION BELOW DECK ON GRADE 4' UNHEATED DRIVEWAY PAN ACCESS ROAD8% MAX SLOPE 15 FT MIN WIDTH 22 FT MAX WIDTH UTILITY EASEMENT 12% MAX SLOPE 14 FT MIN WIDTH LOT 3 LOT 2 2 EXTERIOR PARKING SPACES ; 2 INTERIOR PARKING SPACES ; RE LEVEL 1 PLAN 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.06 SITE PLANGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165708/02/2018 PRE- PERMIT SET NORTH 1" = 10'-0"1 814 THIRD LEVEL - PROPOSED SITE PLAN DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM 15' 3" 3" 3" 6" 12" 15' 15' 18" 8" 8" 6" 8" 15" 6" 8" 6"6"6"3" 8" 6" 6" 8" 10" 12" 10" 6"1 0" 6" 8" 6" 1 0" 3 " 3 " 3"3" 8 " 8" 3" 3" 3" 1 0" 10" 6" 8" 8" 1 0" 10" 10" 10" 10" 12 " 10" 1 0" 10" 12" 8" 8" 15" 15"33558696.30 G 15" 1 0"10" 15' 15"12" 15' 1 0" 6" 6" 8" 6" 8" 6" 10" 6"6" 6"8" 6" 8" 10"12" 15"12" 18" 6" 8" 2461 SF SITE COVERAGE B.O.W. 8686' B.O.W. 8688' B.O.W. 8692' T.O.W. 8689' T.O.W. 8690' T.O.W. 8694' B.O.W. 8690' T.O.W. 8694' B.O.W. 8694' B.O.W. 8697' B.O.W. 8695' T.O.W. 8695' T.O.W. 8698' T.O.W. 8696' B.O.W. 8696' T.O.W. 8698' B.O.W. 8698' T.O.W. 8700' B.O.W. 8696' T.O.W. 8697' B.O.W. 8698' T.O.W. 8700' T.O.W. 8665' B.O.W. 8660' 6" PVC INV. 18" CMP PROPERTY LINE B.O.W. 8683' T.O.W. 8684' DECK ABOVE 20' CLEAR 10% SNOWSTORAGE 2641 SF FEEDER ROAD 10% SNOWSTORAGE 2 1/2" FC 2 1/2" FC 2 1/2" A 2 1/2" A 2 1/2" A 2 1/2" A 3" A 3" A 3" A3" A 3" A 3" A 3" A 3" A2 1/2" A 2 1/2" A 2 1/2" A 2 1/2" A 3" A AC AC ACAC ACAC SC SCSC SC SC P PP PP PP P P P P P AC AC PPP RT RTRT RT RT RT RT RT RT 10' CB 6' DS 10' CB 8' DS 8' DS 6' DS 6' DS 2 1/2" A 2 1/2" A 2 1/2" A 14' ES GSGS GS GS GS GS GS GS GS GS GS GS GS GS GS GS GS GS GS AC ACAC AC AC AC AC AC ACAC AC RT RT RT RT RT RT RT RT OG OG OG OGOG OG OG OG OG OG RTRT RT RT RT RT 10' CB 14' ES 2 1/2" A 2 1/2" A 2 1/2" A 2 1/2" A 2 1/2" A 2 1/2" A 3" A 3" A 3" A 4' UNHE A T E D CON C R E T E PAN SNOW STORAGE 10% SNO W STOR A G E 10% 2 1/2" A 2 1/2" A 2 1/2" A 2 1/2" A 2 1/2" A 2 1/2" A 2 1/2" A LOT 3 LOT 2 NON - COMBUSTIBLE MULCH AND FIRE RESISTANT PLANTINGS INFILL AREA WITH PAVING OR PAVERS TO MEET 20' MIN WIDTH LANDSCAPE LEGEND SEED MIX - NATIVE MOUNTAIN MIX EXISTING DESIDIOUS SNOW STORAGE FOR NON-HEATED SURFACES RETAINING WALL STONE WALKWAY ASPHALT DRIVEWAY PAVERS PROPERTY LINE TOPO. LINE EXISTING CONIFER OG - ORNAMENTAL GRASSES - 2 GALLON - 10 GS - GOLDFLAME SPIREA - 5 GALLON - 23 RT - REDTWING DOGWOOD - 5 GALLON - 23 P - POTENTILLA - 5 GALLON - 15 AC - ALPINE CURRANT - 5 GALLON - 19 FC - FLOWERING CRABAPPLE - 2 1/2" - 1 A - ASPEN - 2 1/2" - 22 A - ASPEN - 3" - 11 CB - COLORADO BLUE SPRUCE - 10' - 3 ES - ENGLEMAN SPRUCE - 14' - 2 SC - SQUAW CURRANT - 5 DS - DWARF SPRUCE - 6' - 3 DS - DWARF SPRUCE - 8' - 2 TOTAL: - 147 NEW PROPOSED TREES" PROPOSED TREE/PLANTING XX" XXX 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.07 LANDSCAPE PLANGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165708/02/2018 PRE-PERMIT SET NORTH 1" = 10'-0"1 814 PPD -LANDSCAPE PLAN 1/8" = 1'-0" LANDSCAPE LEGEND DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM 2461 SF SITE COVERAGE REMOVE 6" ASPEN x2 8" ASPEN x1 10% SNOWSTORAGE REMOVE 3" ASPEN X3 6" ASPEN x2 8" ASPEN x1 REMOVE 3" ASPEN x2 6" ASPEN x3 8" ASPEN x1 10" ASPEN x1 REMOVE 10" ASPEN x2 12" ASPEN x1 REMOVE 6" ASPEN x1 8" ASPEN x3 REMOVE 3" ASPEN x1 ROOF OVERHEAD DECK OVERHEAD REMOVE 6" ASPEN x4 REMOVE 6" ASPEN x1 REMOVE 6" ASPEN x4 8" 6" REMOVE 12" ASPEN x1 LOT 3 LOT 2 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.08 TREE REMOVAL PLANGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET 1" = 10'-0"1 814 PPD - TREE REMOVAL PLAN        DRB APPROVED 9/5/2018 12:00:00 AM B.O.W. 8686' B.O.W. 8688' B.O.W. 8692' T.O.W. 8689' T.O.W. 8690' T.O.W. 8694' B.O.W. 8690' T.O.W. 8694' B.O.W. 8694' B.O.W. 8697' B.O.W. 8695' T.O.W. 8695' T.O.W. 8698' T.O.W. 8696' B.O.W. 8696' T.O.W. 8698' B.O.W. 8698' T.O.W. 8700' B.O.W. 8696' T.O.W. 8697' B.O.W. 8698' T.O.W. 8700' T.O.W. 8665' B.O.W. 8660' PROPERTY LINE B.O.W. 8683' T.O.W. 8684' EXISTING DRIVEWAY 8% SLOPE BUILDING FOOTPRINT20'-0"EXISTING FEEDER ROAD 20 FT MIN. WIDTH INFILL AREA WITH PAVING OR PAVERS TO MEET 20' MIN WIDTH 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.09 GRADING PLANGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET 1" = 10'-0"1 814 PPD - GRADING PLAN DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM 814/LOT 3 815/LOT 2 PROPERTY LINE 10' SETBACK 15' SETBACK BUILDING FOOTPRINT BUILDING FOOTPRINT 5'-0"10'-0" 15'-0" 5'-0 " 10 '-0 " 15 '-0 "2461 SF BUILDING COVERAGE 2641 SF FEEDER ROAD 727 SF DRIVEWAY 3843 SF DRIVEWAY 5130 SF BUILDING COVERAGE 815/LOT 2 REQUIREMENTS SITE AREA NON-BUILD. AREA BUILDABLE AREA BUILDING COVERAGE ALLOWED BUILDING COVERAGE PROPOSED LANDSCAPE AREA HARDSCAPE AREA SOFTSCAPE AREA 30,000 SF (.6887 ACRES) 8,557 SF 21,443 SF 30,000 SF X .2 = 6,000 SF 5,130 SF 21,027 SF = 70% 2,120 SF = 10% 18,907 SF = 90% FITS 80'X80' BOX MEETS SETBACK REQ. YES YES SITE COVERAGE 8,973 SF = 30% 814/LOT 3 REQUIREMENTS SITE AREA NON-BUILD. AREA BUILDABLE AREA BUILDING COVERAGE ALLOWED BUILDING COVERAGE PROPOSED LANDSCAPE AREA HARDSCAPE AREA SOFTSCAPE AREA 17,322 SF (.3977 ACRES) 1,953 SF 15,369 SF 17,322 SF X .2 = 3,464 SF 2,461 SF 11,493 SF = 66% 835 SF = 7% 10,658 SF = 93% FITS 80'X80' BOX MEETS SETBACK REQ. YES YES SITE COVERAGE 5,829 SF = 34% 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.10 P.E.C. REQUIREMENTSGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET 1" = 20'-0"1 814 PPD - P.E.C. LOT SIZE 1" = 20'-0"2 814 PPD - P.E.C. SETBACKS 1" = 20'-0"3 814 PPD - P.E.C. 80' X 80' 1" = 20'-0" 4 814 PPD - P.E.C. LANDSCAPE AREA CALC. DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM 5/8" GYPSUM WALL BOARD 3 1/2" W4-4 2X4 DIMENSIONAL LUMBER @ 16" O.C., SEE PLANS AND WALL TAG FOR LUMBER SIZE, TYP. SOUND BATTS 5/8" GYPSUM WALL BOARD 5 1/2" W4-6 2X6 DIMENSIONAL LUMBER @ 16" O.C., SEE PLANS AND WALL TAG FOR LUMBER SIZE, TYP. SOUND BATTS 2X8 DIMENSIONAL LUMBER @ 16" O.C., SEE PLANS AND WALL TAG FOR LUMBER SIZE, TYP. 5/8" GYPSUM WALL BOARD 7 1/4" W4-8 SOUND BATTS 2X8 DIMENSIONALLUMBER @ 16" O.C. 5/8" GYPSUM WALL BOARD INTERIOR VERTICAL WOOD SIDING EXTERIOR SPRAY-IN INSULATION, R-21 MIN. BUILDING WRAP STRUCTURAL SHEATHING, RE: STRUCTURE W1 -S1 Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general. WALL SYSTEMS: RATED ASSEMBLIES (@ MAIN & UPPER LEVELS): F1-W WOOD PLANK ON GYPCRETE Wood plank installed per manufacturer's specifications, over 1 1/2" thick light concrete underlayment over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured floor trusses at 16" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "x"gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses. F1-C CARPET ON GYPCRETE Carpet and pad, installed per manufacturer's specifications, over 1 1/2" thick light weigth concrete underlayment over 1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured floor trusses at 24" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "X" gypsum board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses. ASSEMBLIES (@ BASEMENTS): F2-W WOOD PLANKS ON CONCRETE SLAB Wood plank flooring per manufacturer's specifications, over felt underlayment installed per manufacturer's specifications, over concrete slab. Provide transitions strips where there is a material change in floor finish. F2-C CARPET ON CONCRETE SLAB Carpet per manufacturer's specifications, over carpet underlayment installed per manufacturer's specifications, over concrete slab. Provide transitions strips where there is a material change in floor finish. F2-T TILE ON CONCRETE SLAB 12"x12" Ceramic Tile on thin set mortar on concrete slab. Provide transitions strips where there is a material change in floor finish. F2-CT CERAMIC TILE ON CONCRETE SLAB W" x H" Ceramic Tile (TBD) on thin set mortar over concrete slab. Provide transitions strips where there is a material change in floor finish. F2-S STONE ON CONCRETE SLAB W" x H" Stone (TBD) on thin set mortar over concrete slab. Provide transitions strips where there is a material change in floor finish. ASSEMBLIES (@ GARAGE): F3 CONCRETE SLAB ON GRADE WITH GARAGE FINISH Structural concrete slab with sloped concrete topping. RE: Structure. Finish with a garage finish (TBD). C1 GYPSUM BOARD CEILING CONSTRUCTION 5/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses. (TYPICAL FOR ALL CEILINGS) Note: Typical ceiling system included in floor assemblies. Re: floor assemblies. C2 W T&G CEILING CONSTRUCTION (Non-Rated) Tongue & groove inlay. CEILING SYSTEMS: FLOOR SYSTEMS: NOTES * Stone veneer to be installed in strict conformance with ESR Reports (ICC) for manufacturer selected. Comply with the Rocky Mountain Masonry Institute requirements & specifications for systems not evaluated by ICC, 2009 International Building Code requirements and industry recognized trade standards. ** Interior Walls Studs: 4 - 2x4 Wood Studs 6 - 2x6 Wood Studs 8 - 2x8 Wood Studs RE: See wall tags for stud sizes. **** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistant non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where recommended by manufacturer. Maintain required fire-rating. Refer to Structural Drawings for Bearing Walls and Shear Walls. RATED ASSEMBLIES (EXTERIOR): W1-S1 VERTICAL WOOD SIDING @ RATED EXTERIOR WALLS ( PRIMARY COLOR ) EXTERIOR Vertical Wood Siding - TBD Tyvek Building Wrap Structural Sheathing, per structural 2x dimensional lumber, @ 16" per structural w/ R-21 min. spray-in, closed cell insulation (1) layer 5/8" gypsum board INTERIOR W1-S2 WOOD SIDING @ EXISTING EXTERIOR WALLS ( PRIMARY COLOR ) EXTERIOR Vertical Wood Siding - TBD Tyvek Building Wrap Structural Sheathing, per structural Existing 2x dimensional lumber, @ 16" per structural w/ R-21 min. spray-in, closed cell insulation (1) layer 5/8" gypsum board INTERIOR RATED ASSEMBLIES (INTERIOR): W2 GYPSUM SHEATHING @ RATED INTERIOR GARAGE SEPARATION WALLS (1-Hr. Fire Rated Assembly UL Design No. U356) (1) layer 5/8" Type "X" gypsum sheathing @ garage interior face of 2x6 wood studs w/ R-20 batt insulation between studs. (1) layer 5/8" gypsum board @ non-garage face of studs. (Re: Structural for size and spacing of studs and sheathing). W3 GYPSUM SHEATHING @ UNIT SEPARATION WALLS (2-Hr. Fire Rated Assembly UL Design No. Uxxxx) PARTY WALL - (1) layer 5/8" Type "X" gypsum sheathing @ both sides of 2x6 wood studs w/ R-20 batt insulation between studs. 1" air cavity. (1) layer 5/8" Type "X" gypsum sheathing @ both sides of 2x6 wood studs w/ R-20 batt insulation between studs. NON-RATED ASSEMBLIES (INTERIOR): W4-*** GYPSUM BOARD PARTITION ON 2 x WOOD STUDS (Non-Rated) (1) Layer 5/8" gypsum board**** on each side of 2x wood studs at non-bearing walls demising bedrooms and living areas. Sound batt insulation. (Re. Structural for size and spacing). W5- GYPSUM BOARD OVER FURRING (Non-Rated) (1) Layer 5/8" gypsum board**** over 1 1/2" metal furring strips @ 16" O.C. with 1 1/2" rigid insulation. (Re. Structural for size and spacing). (1Hr-Rated), R-50 R1 STANDING SEAM METAL ROOF CONSTRUCTION: EXTERIOR Standing Seam Metal Roof, mechanically fastened Ice and water shield, 40mm min. Structural sheathing, per structural 11 7/8" structural LVL, Re: Structural w/ R-21 min. spray-in, closed cell insulation 7/8" 25 guage galvanized steel furring channels (1) layer 5/8" gypsum board or T&G wood finish, see A6.04 - Room Finish Schedule INTERIOR R2 SKYLIGHT SYSTEM: Sklight by others. Coordinate with GC and structural. 110 MPH Wind resistance (ASTM D 3161), Class 4 impact resistance (UL 2218), ICC-ES (ESR-2119), Miami Dade Code Approval ROOF SYSTEMS: INTERIOR WALL ASSEMBLIES: 5/8" GYPSUM WALL BOARD W4-2 2X4 DIMENSIONAL LUMBER FLAT FRAMED @ 16" O.C., SEE PLANS AND WALL TAG FOR LUMBER SIZE, TYP. RIGID INSULATION BETWEEN FRAMING EXISTING 2X DIMENSIONAL LUMBER OR METAL STUDS @ 16" O.C. 5/8" GYPSUM WALL BOARD INTERIOR 3 COAT STUCCO SYSTEM EXTERIOR BUILDING WRAP STRUCTURAL SHEATHING, RE: STRUCTURE W1 -S2 SPRAY-IN INSULATION, R-21 MIN. 2X8 DIMENSIONAL LUMBER @ 16" O.C. 5/8" GYPSUM WALL BOARD INTERIOR EXTERIOR PORCELAIN TILE EXTERIOR BATT INSULATION, R-21 MIN. BUILDING WRAP STRUCTURAL SHEATHING, RE: STRUCTURE W1 -M1 5/8" GYPSUM WALL BOARD INTERIOR EXTERIOR CLOSED CELL INSULATION SPRAY-IN, R-49 MIN. R-1 STRUCTURAL SHEATHING STRUCTURAL FRAMING VYCOR ICE AND WATER BARRIER METAL ROOF SLOPE, SEE PLANS INTERIOR EXTERIOR PORCELAIN TILE EXTERIOR CONCRETE WALLS GROUT RE: STRUCTURE W1 -M2 EXTERIOR (SOME EXTERIOR WALLS WILL HAVE TILE ON BOTH SIDES) PARTY WALL, STAGGERED 2X6 STUDS ON 2X8 PLATE, DIMENSIONAL LUMBER @ 16" O.C., TYP. 5/8" GYPSUM WALL BOARD W4-8p SOUND BATTS 7/8" HAT CHANNELS, 25-GAUGE TYP. SPACING 1'-4" TYP. SPACING 1'-4" 5/8" GYPSUM WALL BOARD 7/8" HAT CHANNELS, 25-GAUGETYP. SPACING 1'-4" SOUND BATTS 5/8" GYPSUM WALL BOARD, TYPE X, TYP. 5 1/2" W3 2X6 DIMENSIONAL LUMBER @ 16" O.C.,TYP. BATT INSULATION, TYP. 5/8" GYP. = 40 MIN. x2 FIRE RATED: 1 HOUR MIN. 2x8 FRAMING (X2) @ 16" O.C.= 20 MIN. BATT INSULATION = 15 MIN. FIRE RATING (1-HOUR MIN.) : INTERIOR GARAGE 5/8" GYPSUM WALL BOARD, TYPE X, TYP. 5 1/2" 1 1/2" W2 2X6 DIMENSIONAL LUMBER @ 16" O.C.,TYP. 1 1/4" 1 1/2" 5 1/2" 1" 1" AIR CAVITY, TYP. BATT INSULATION, TYP. 5/8" GYP. = 40 MIN. X6 FIRE RATED: 2 HOUR MIN. 2x8 FRAMING (X2) @ 16" O.C.= 20 MIN. X2 BATT INSULATION = 15 MIN. X2 FIRE RATING (2-HOUR MIN.) : 7/8" RESILIENT CHANNEL, TYP. FOUNDATION WALL, RE: STRUCTURE, TYP. 5/8" GYPSUM WALL BOARD W5 1 1/2" METAL FURRING @ 16" O.C., TYP. 1 1/2" RIGID INSULATION BETWEEN FURRING, TYP. 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.11 ASSEMBLIESGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET 1 1/2" = 1'-0"1 INTERIOR PARTITION (2X4) W4-4 1 1/2" = 1'-0"2 INTERIOR PARTITION (2X6) W4-6 1 1/2" = 1'-0"3 INTERIOR PARTITION (2X8) W4-8 3" = 1'-0"5 W1-S1 - WOOD SIDING 1 1/2" = 1'-0"9 INTERIOR FURRING (2X4) W4-2 3" = 1'-0"4 W1-S2 - WOOD SIDING ( ALT. COLOR ) 3" = 1'-0"7 W1-M1 - PORCELAIN TILE ON FRAMING 3" = 1'-0"10 ROOF ASSEMBLY 3" = 1'-0"6 PORCELAIN TILE ON CONCRETE 1 1/2" = 1'-0"11 INTERIOR PARTITION (2X8) W4-8p (PARTY WALL ASSEMBLY) 1 1/2" = 1'-0"8 GARAGE SEPARATION W3 1 1/2" = 1'-0"12 INTERIOR UNIT SEPARATION W2    DRB APPROVED 9/5/2018 12:00:00 AM D UP D 1223 SF 279 SF 74 SF 363 SF UNIT B 612 SF UNIT A 109 SF UNIT B 290 SF UNIT A 105 SF 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.12 PROPOSED SNOWMELTGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165705/10/18 PRE-PERMIT SET 1/8" = 1'-0"1 LOWER / ENTRY LEVEL PROPOSED SNOWMELT 1/8" = 1'-0"2 SECOND LEVEL PROPOSED SNOWMELT 1/8" = 1'-0" 3 THIRD LEVEL PROPOSED SNOWMELT 1/8" = 1'-0"4 FOURTHLEVEL PROPOSED SNOWMELT 3,055 SF TOTAL 1360 UNIT A 1695 UNIT B * POSSIBLY AN ADDITIONAL 600 SF FOR UNIT A DRIVEWAY POSSIBLY AN ADDITIONAL 440 SF FOR UNIT A EXISTING DECK DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM UP AREA TO BE DISTURBED IN CONSTRUCTION 9,350 SF TOTAL 9,350 SF / 20,024 SF = 47% CONSTRUCTION FENCE 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A0.13 SITE DISTURBANCE CALC.GALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165708/02/2018 PRE-PERMIT SET 1" = 10'-0"1 814 THIRD LEVEL -PROPOSED SITE PLAN DISTURBANCE CALC DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM 22'- 7" FROM GRADE 32' - 10" FROM ORIGINAL GRADE30'- 11" FROM GRADE 31'- 4 1/2" FROM GRADE DECK OVER ENTRY 20'-6" FROM GRADE 21'-10 1/2" FROM GRADE ARCHITECTURAL FEATURE DECK OVER GARAGE ARCHITECTURAL FEATURE 26'-0" FROM GRADE 8709' - 3 1/2" 8707' - 10 1/2" 8700' - 6" ALL ROOFING WILL BE CLASS-A METAL ROOFING, TYP. METAL CAP ON CHIMNEY SHROUD PROVIDE 220 VOLT HEAT TAPE FOR ALL DRAINS, GUTTERS AND DOWNSPOUTS 8683' - 3 1/2" 8686' - 0" 8707' - 11" 8677' - 0" 90°90°8665' - 5 1/2" 94 °90°270°90°270°90°90°90°95°265°8698' - 1" 8680' - 0" 8709' - 9" 8687' - 2"1" / 1'-0"1" / 1'-0"95°8700' - 2 1/2" 8708' - 8 1/2" 8682' - 8 1/2" 26'-0" FROM GRADE 8705' - 8" 8707' - 3 1/2" 32' - 10" FROM ORIGINAL GRADE 29' - 0" FROM ORIGINAL GRADE 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A1.00 ROOF PLANGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET NORTH 1/4" = 1'-0"1 ROOF PLAN PROVIDE 220 VOLT HEAT TAPE FOR ALL DRAINS, GUTTERS AND DOWNSPOUTS    DRB APPROVED 9/5/2018 12:00:00 AM 62 64 66 68 70 72 74 76 78 80 82 84 86 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A1.00a ORIGINAL GRADEGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET DATE NO. DESCRIPTION 1/8" = 1'-0" ORIGINAL GRADE DRB APPROVED 9/5/2018 12:00:00 AM UP UP D D UP GARAGE 1 8661' - 4" A2.021 A2.04 2 A2.03 2 108 PROPOSED DUMPSTER LOCATION 102 POWDER 1 5 STORAGE/FLEX SPACE 2 THEATER 4 MUDROOM 3 EXISTING STAIR AND HANDRAIL HBA2.01 1 105 A4.10 1 20 MIN DOOR FOR GARAGE SEP. 37" RAILING HAND RAIL PER CODE REMOVE RANGE INSTALL MICROWAVE IN EXISTING KITCHEN 8661' - 4" PROPOSED ELEVATOR USE EXISTING SLOPE AND DRAINS PROPOSED STAIR 7 RISERS @ 6 3/4:11 8665'-3 1/4" T.O. CONCRETE 8665'-3 1/4" T.O. CONCRETE 8665'-3 1/4" T.O. CONCRETE 8668' - 5" 103 104 101 106 MECHANICAL ROOM 6 135° A4.09 5 NO SLEEPING ARRANGEMENTS INTENDED FOR BASEMENT LEVEL NEW WALLS EXISTING WALLS WALLS TO BE DEMOLISHED DEMO LEGEND 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A1.01 1ST LEVELGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165708/02/2018 PRE- PERMIT SET NORTH1/4" = 1'-0" 1 LOWER ENTRY AND GARAGE 1/16" = 1'-0"2 814 LOWER LEVEL EXISTING DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM BEDROOM 4 10 A2.03 2 207 BATH 4 11 LAUNDRY 12 A2.01 1 OPEN TO BELOW EXISTING STAIR 203 FPHBDN DN DN W1-S2 W1-M1 W4-4 8674' - 1" T.O. SHEATHING 8674' - 5" T.O. SHEATHING 8674' - 5" T.O. SHEATHING 8674' - 6 1/2" T.O. SHEATHING 13'-0"4'-6"12'-6 1/2" 12'-6 1/2" 10'-0"10'-0"10'-0"10'-11"12'-8" NEW PORTION OF STAIR WALL EXISTING STAIRS TO REMAIN LOWER LIVING ROOM 14 BEDROOM 1 98 BEDROOM 2 102 BEDROOM 3 103 POWDER ROOM 2 104 ENTRY FOYER 101 SLIDING GLASS DOORS 201 209 211 212 215 201 205 206 202 204 210 217 214 213 216 208 218 219 220 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A1.02 2ND LEVELGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET 1/4" = 1'-0"1 SECOND LEVEL 1/16" = 1'-0"2 814 SECOND LEVEL - EXISTING    DRB APPROVED 9/5/2018 12:00:00 AM BAR / LOUNGE AREA 22 OUTDOOR DINING AREA 17 EXISTING STAIR TO REMAIN OUTDOOR GRILLING AND COUNTER AREA NEW DECK AREA DN A2.021 A2.04 2 A2.03 2 BUILT-IN SHELVESOR BUFFETLIVING 18 KITCHEN 19 PANTRY 20 A2.01 1 OPEN TO BELOW EXISTING STAIR DN DN DN FPHB FPHB399 CFM EXHAUST HOOD 8687' - 7" T.O. SHEATHING 8687' - 3" T.O. SHEATHING FIRE PIT 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A1.03 3RD LEVELGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET NORTH 1/16" = 1'-0"1 814 THIRD LEVEL - EXISTING 1/4" = 1'-0" 2 THIRD LEVEL DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM A2.021 A2.04 2 A2.03 2 MASTER BEDROOM 23 A2.01 1 PROPOSED FIREPLACE CONTINUATION OF PROPOSED ELEVATOR PROPOSED DECK DN FPHB EXISTING STAIR TO REMAIN 8697' - 5" T.O. SHEATHING 8697' - 1" T.O. SHEATHING MASTER BATH 105 MASTER CLOSET 26 ROOF BELOW NEW WALLS EXISTING WALLS WALLS TO BE DEMOLISHED DEMO LEGEND 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A1.04 4TH LEVELGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET 1/4" = 1'-0"1 FOURTH LEVEL 1/16" = 1'-0"2 814 FOURTH LEVEL - EXISTING DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM SECOND LEVEL 8674' - 8" THIRD LEVEL 8687' - 10" GARAGE 8661' - 4" LOWER ENTRY AND GARAGE 8665' - 3 1/4" FOURTH LEVEL 8697' - 8" TYP. 3 TYP.7 TYP.10 8705' - 8" 8698' - 1 1/2" 8700' - 6 1/2" 8700' - 2 3/4" 8707' - 9 1/2" 8709' - 2 1/2" 8709' - 9" 8708' - 8 1/2" 8707' - 3 1/2" 3/A6.01 1/A6.01 1/A6.01 1/A6.01 6/A6.02 4/A6.02 4/A6.01 3/A6.02 5/A6.02 TYP.3 TYP.13 TYP.10 TYP.1 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A2.01 SOUTH ELEVATIONGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165708/14/2018 PRE- PERMIT SET KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 WOOD SIDING - 1x, RUSTIC 3 STANDING SEAM METAL ROOF 6 METAL BRACKET 7 METAL RAILING 8 METAL C-CHANNEL 10 PORCELANOSA PANELS 13 STUCCO - COLOR #1 SOUTH ELEVATION EXISTING 1/4" = 1'-0"1 SOUTH ELEVATION - PROPOSED DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM SECOND LEVEL (A&B) 8674' - 8" THIRD LEVEL 8687' - 10" THIRD LEVEL 8687' - 10" GARAGE (A) 8661' - 4" FOURTH LEVEL 8697' - 8" TYP.13 TYP.1 TYP. 8 TYP.10 TYP. 10 SPA DECK(A) 8672' - 2" 8698' - 1 5/32" 8700' - 6 5/32" 8707' - 10 19/32" 8705' - 7 31/32" 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A2.02 EAST ELEVATIONGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET 1/4" = 1'-0"1 EAST ELEVATION - PROPOSED KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 WOOD SIDING - 1x, RUSTIC 2 STONE - COLORADO BUFF 3 STANDING SEAM METAL ROOF 6 METAL BRACKET 7 METAL RAILING 8 METAL C-CHANNEL 10 PORCELANOSA PANELS 13 STUCCO - COLOR #1 EAST ELEVATION EXISTING    DRB APPROVED 9/5/2018 12:00:00 AM SECOND LEVEL (A&B) 8674' - 8" THIRD LEVEL 8687' - 10" GARAGE (A) 8661' - 4" FOURTH LEVEL 8697' - 8" TYP.1 TYP.7 TYP.6 TYP.8 TYP.3 SPA DECK(A) 8672' - 2" 8700' - 6 5/32" 8707' - 10 19/32" 8708' - 6 7/8" ENTRY LANDING 1 8666' - 6 19/32" ENTRY LANDING 2 8671' - 9" 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A2.03 NORTH ELEVATIONGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET 1/4" = 1'-0"2 NORTH ELEVATION PROPOSED KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 WOOD SIDING - 1x, RUSTIC 2 STONE - COLORADO BUFF 3 STANDING SEAM METAL ROOF 6 METAL BRACKET 7 METAL RAILING 8 METAL C-CHANNEL 10 PORCELANOSA PANELS 13 STUCCO - COLOR #1 NORTH ELEVATION EXISTING    DRB APPROVED 9/5/2018 12:00:00 AM SECOND LEVEL (A&B) 8674' - 8" THIRD LEVEL 8687' - 10" GARAGE (A) 8661' - 4" LOWER ENTRY AND GARAGE 8665' - 3 1/4" FOURTH LEVEL 8697' - 8" SPA DECK(A) 8672' - 2" ENTRY LANDING 3 8674' - 8" 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A2.04 WEST ELEVATIONGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET 1/4" = 1'-0"2 WEST ELEVATION - PROPOSED KEYNOTE LEGEND KEY VALUE KEYNOTE TEXT 1 WOOD SIDING - 1x, RUSTIC 2 STONE - COLORADO BUFF 3 STANDING SEAM METAL ROOF 6 METAL BRACKET 7 METAL RAILING 8 METAL C-CHANNEL 10 PORCELANOSA PANELS 13 STUCCO - COLOR #1 WEST ELEVATION EXISTING DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM SECOND LEVEL 8674' - 8" A B G FC D E THIRD LEVEL 8687' - 10" GARAGE 8661' - 4" LOWER ENTRY AND GARAGE 8665' - 3 1/4" FOURTH LEVEL 8697' - 8" F.2 4 A3.11 5 A3.11 4 A4.09 2 A3.12 1 A3.021 A3.03 1 A3.04 G.1 G.2 R1 R1 MASTER BEDROOM 32 BAR / LOUNGE AREA 22 BEDROOM 4 12 STORAGE/FLEX SPACE 2 ? ? KITCHEN 25 ? ? POWDER 1 5 ? ? ENTRY LANDING 1 8666' - 6 1/2" ENTRY LANDING 2 8671' - 9" 1'-2" F.1 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A3.01 BUILDING SECTION 1GALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165708/02/2018 PRE- PERMIT SET 1/4" = 1'-0"1 BUILDING SECTION 1 DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM SECOND LEVEL 8674' - 8" 2 1 3 7 85 6 THIRD LEVEL 8687' - 10" LOWER ENTRY AND GARAGE 8665' - 3 1/4" FOURTH LEVEL 8697' - 8" 4 1 A3.01 A4.09 4 ENTRY LANDING 1 8666' - 6 1/2" ENTRY LANDING 2 8671' - 9" 2a 3a 3d 3c3b 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A3.02 BUILDING SECTION 2GALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165708/02/2018 PRE- PERMIT SET 1/4" = 1'-0"1 BUILDING SECTION 2 DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM SECOND LEVEL 8674' - 8" 2 1 3 7 8 5 6 THIRD LEVEL 8687' - 10" LOWER ENTRY AND GARAGE 8665' - 3 1/4" FOURTH LEVEL 8697' - 8" 4 1 A3.01 BAR / LOUNGE AREA 22 MASTER BEDROOM 32 LOWER LIVING ROOM 10 THEATER 4 9.1 R1 R1 W1-S1 EXISTING STAIR TO REMAIN METAL GRATE ENTRY LANDING 1 8666' - 6 1/2" ENTRY LANDING 2 8671' - 9" 2a 3a 3d 3c3b 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A3.03 BUILDING SECTION 3GALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165708/02/2018 PRE-PERMIT SET 1/4" = 1'-0" 1 BUILDING SECTION 3 DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM SECOND LEVEL 8674' - 8" GARAGE 8661' - 4" FOURTH LEVEL 8697' - 8" 1 A3.01 BEDROOM 4 12 GARAGE 1 STORAGE/FLEX SPACE 2 R1 KITCHEN 25 LIVING 26 ENTRY LANDING 1 8666' - 6 1/2" ENTRY LANDING 2 8671' - 9" W4-4 W4-4 W4-6 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A3.04 BUILDING SECTION 4GALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 8165708/02/2018 PRE-PERMIT SET 1/4" = 1'-0"1 BUILDING SECTION 4 DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A9.01 3D MODELGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A9.02 3D MODELGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET    DRB APPROVED 9/5/2018 12:00:00 AM 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A9.03 3D MODELGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 A9.04 3D MODELGALLERY RESIDENCEProject Number - 1733814 POTATO PATCH DRVAIL, CO 816577/16/2018 DRB SET DATE NO. DESCRIPTION DRB APPROVED 9/5/2018 12:00:00 AM