HomeMy WebLinkAboutDRB18-0422_Approved Documents_1536260547.pdfACTION FORM
Design Review Board (DRB)
Department of Community Development
75 South Frontage Road West
Vail, CO 81657
Tel: 970-479-2139
www.vailgov.com
Project Name: Schroeder Residence 2018 Application Number: DRB18-0422
Application Type: Exterior Alteration Date Applied: 08/21/2018
Project Description:
Remove and Replace the existing 3 fireplaces. All fireplaces will vent vertically
through the existing chimney chases and exit in their current locations. We will
use new exterior vent terminations designed for the the new fireplaces. These
will similar to the existing terminations. There interior will receive a minor
remodels at the fireplace locations. The Living Room will get a thin stone
surround extending form floor to ceiling. The Master Bedroom and Upper
Bedroom will receive new tile surrounds to replace the existing tile.
CONTACTS
Contact Type: Applicant
Full Name: ULF Built (Justin Wohlrabe)
Address: 275 Main St. C-105 Edwards, CO 81632 Phone: 9706881781
Contact Type: Property Owner
Full Name: SCHROEDER, BRETT R. & HEIDI S.
Address: Phone: None
Project Address: 950 RED SANDSTONE RD 14 (210106306014 14) (210106306014)
Job Site Location: 14
Legal Description: Subdivision:POTATO PATCH CLUB
CONDOMINIUMS Lot: No Data Block:No
Data
Parcel Number: 210106306014
BOARDS/STAFF ACTION
Motion By: Action: Staff Approved
Second By:
Vote: Date: 09/06/2018
Conditions:
- All exposed metal flashing, trim, flues, vents, and rooftop mechanical equipment shall be anodized, painted
(adjacent facade/roof material color or flat black), or capable of weathering so as to be non-reflective
pursuant to Section 14-10-5C, Building Materials and Design, Vail Town Code, pror to requesting final
inspections.
- Approval of this project shall lapse and become void one (1) year following the date of final approval, unless
a building permit is issued and construction is commenced and is diligently pursued toward completion.
- Design Review Board approval does not constitute a permit for building. Please consult with Town of Vail
building personnel prior to construction activities.
- Design Review Board approval shall not become valid for 20 days following the date of approval, pursuant
to the Vail Town Code, Chapter 12-3-3 Appeals.
- No changes to these plans maybe made without the written consent of Town of Vail staff and/or the
appropriate review committee(s).
Planner: Chris Neubecker
PLANNING FEE RECEIPT
Case # DRB18-0422
Date Printed: 08/29/2018
TOWN OF VAIL - FEES RECEIPT
Planning Summary
Type: Design Review Board (DRB) Submittal Date: 08/21/2018
Subcases: Exterior Alteration
Bond Expire Date:
Description of Work:
Remove and Replace the existing 3 fireplaces. All fireplaces will vent vertically through the existing
chimney chases and exit in their current locations. We will use new exterior vent terminations
designed for the the new fireplaces. These will similar to the existing terminations. There interior will
receive a minor remodels at the fireplace locations. The Living Room will get a thin stone surround
extending form floor to ceiling. The Master Bedroom and Upper Bedroom will receive new tile
surrounds to replace the existing tile.
Property Information
Address: 950 RED SANDSTONE RD 14 (210106306014 14) Tax ID: 210106306014
Owner: SCHROEDER, BRETT R. & HEIDI S.
Contacts
Contact Type: Applicant
Company Name: ULF Built
Full Name: Justin Wohlrabe
Address: 275 Main St. C-105 Edwards, CO 81632
Email: justin@ulfbuilt.com
Contact Type: Property Owner
Full Name: SCHROEDER, BRETT R. & HEIDI S.
Address:
Planning Fees
Fee Information Account Amount
DRB - Exterior Alteration 001-0000.31122.00 $230.00
Payment Information Date Paid Payment Type Amount
DRB - Exterior Alteration 08/29/2018 Check $230.00
Paid By: Ulf & Associates - Notes: ck#3287
FEE TOTAL $230.00
AMOUNT PAID $230.00
BALANCE DUE $0.00
08/29/2018 - 1:52:03 PM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657
1 / 1
PLANNING FEE RECEIPT
Case # DRB18-0422
Date Printed: 08/22/2018
TOWN OF VAIL - FEES RECEIPT
Planning Summary
Type: Design Review Board (DRB) Submittal Date: 08/21/2018
Subcases: Exterior Alteration
Bond Expire Date:
Description of Work:
Remove and Replace the existing 3 fireplaces. All fireplaces will vent vertically through the existing
chimney chases and exit in their current locations. We will use new exterior vent terminations
designed for the the new fireplaces. These will similar to the existing terminations. There interior will
receive a minor remodels at the fireplace locations. The Living Room will get a thin stone surround
extending form floor to ceiling. The Master Bedroom and Upper Bedroom will receive new tile
surrounds to replace the existing tile.
Property Information
Address: 950 RED SANDSTONE RD 14 (210106306014 14) Tax ID: 210106306014
Owner: SCHROEDER, BRETT R. & HEIDI S.
Contacts
Contact Type: Applicant
Company Name: ULF Built
Full Name: Justin Wohlrabe
Address: 275 Main St. C-105 Edwards, CO 81632
Email: justin@ulfbuilt.com
Contact Type: Property Owner
Full Name: SCHROEDER, BRETT R. & HEIDI S.
Address:
Planning Fees
Fee Information Account Amount
DRB - Exterior Alteration 001-0000.31122.00 $20.00
Payment Information Date Paid Payment Type Amount
DRB - Exterior Alteration 08/22/2018 Check $20.00
Paid By: Ulf & Associates - Notes: 3230 - Ulf & Associates
FEE TOTAL $20.00
AMOUNT PAID $20.00
BALANCE DUE $0.00
08/22/2018 - 11:11:48 AM - Generated by: dcouch75 South Frontage Road West, Vail, Colorado 81657
1 / 1
38
Initial Installation
QUALIFIED INSTALLERS ONLY
Step 4. Assemble the desired
lengths of black pipe
and elbows necessary to
reach from the appliance
adapter up through the
Round Support Box.
Insure that all pipe and
elbow connections are
in their fully twist-locked
position.
Figure 46. Vertical Vent Termination
Step 4. With the hole now framed, the wall thimble installed, and the pipe extending into the wall,
proceed to the outside. Attach the termination to the pipe using RTV and Mil-Pac or Rutland No
78 Stove and Gasket Cement to seal joints. The vent pipe must extend into the vent cap at least
1¼ inches (3.2 cm). Secure the connection between the vent cap and the pipe by attaching
the two (2) sheet metal straps, which extend from the vent cap assembly to the outer wall of
the vent pipe. Bend any remaining portion of the strap back towards the vent cap. Security
Secure Vent uses a twist lock cap.
Step 5. Position the horizontal vent termination in the center of the 10 (25.4 cm) square hole and
attach to the exterior wall with the four screws provided. The arrow on the vent termination
should be pointing up. Run a bead of non-hardening mastic around the edges of the vent
cap, to make a seal with the wall. Ensure the proper clearances to combustibles have been
maintained.
VeRticaL teRmination:
Step 1. Check the instructions for required clearances (air spaces) to combustibles when passing
through ceilings, walls, roofs, enclosures, attic rafters, or other nearby combustible surfaces.
Do not pack air spaces with insulation.
Step 2. Set the gas appliance in the desired location. Drop a plumb bob down from the ceiling to
the position of the appliance flue exit, and mark the location where the vent will penetrate
the ceiling. Drill a small hole at this point. Next, drop a plumb bob from the roof to the hole
previously drilled in the ceiling, mark the spot where the vent will penetrate the roof. Determine
if ceiling joists, roof rafters, or other framing will obstruct the venting system. You may wish to
relocate the appliance, or to offset, to avoid cutting load bearing members.
Step 3. To install the Round Support Box/Wall Thimble in a flat ceiling, cut a 10 (25.4 cm) square
hole in the ceiling, centered in the hole drilled in Step 2. Frame the hole as shown in Figure 26.
Vertical
Termination
Storm Collar
Flashing
Roofing nails
Elbow Strap
Clearances in horizontal venting.
Straight-through roof support configuration b) Flex bend configuration c) Termination mounting
FDVVT40
-Restrictor-
Remove for Runs
Under 15 Feet
77
Page 11XG0213 - 151126
H*38DF-CLCR Corner Gas Fireplace
Installation
Section:
Figure 9. Top vent, Roof mounted termination with no offset in
vent run.
Figure 9a. Top vent, Roof mounted with 1 offset (1 offset= two 90°
bends).
Figure 9b. Top vent, Roof mounted with 2 offsets (1 offset= two
90° bends).
Roof mounted Terminations
The following details are some possible configurations for Roof
mounted terminations.
Support ring
Support plate
Firestop
32 max.
2 min.
Obstacle
PVTK1
Termination
Support ring
Support plate
Firestop
32 max.
2 min.
PVTK1
Termination
Support straps or
support plate & ring
2 min.
Firestop
Firestop
Firestop
32 max
Support plate
& ring
Obstacle
PVTK1
Termination
This section applies to installations where the direct vent termi-
nation will be roof mounted.
Section 3-2-1: Venting Layout
Selection of components and details of venting lay out should
adhere to the following guidelines:
The maximum termination point is 32’ above the fireplace
(NOTE: if the maximum termination height is used, the flame
pattern may be affected).
The Vertical termination must be a minimum 2 higher than where
the termination exits the roofing materials, (asphalt shingles,
cedar shakes, etc). This distance should be measured from the
high side of the roof slope where the flue flashing intersects
the roofing materials. (see Figures 9 to 9c).
Termination location must be a minimum 6 from a mechanical
air inlet.
Termination location must be a minimum 18 from a parapet wall.
For a more detailed diagram of allowed termination locations,
see Appendix A.
A maximum of two offsets (each offset is made up of 2-90°
bends) may be made for vertical vent runs.
Firestops must be installed as required by National & local codes
Ensure all horizontal runs are supported with a minimum of 3
supports per 10 of venting.
Install all roof flashing and storm collars as shown.
Section 3-2: Installing a Roof Mounted Direct Vent
Termination (PVTK-1)