Loading...
HomeMy WebLinkAboutB18-0329_Approved Plans_1539358750.pdfCondition of Approval: All brackets/hardware shgall be painted black or painted to match the roof color. 10/12/18 10/12/18 10/12/18 Page 1 of 4 8/8/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Solar Installation Information Vendor: Active Energies Solar LLC PO Box 7627 Avon, CO 81620 (970-306-4233 /info@activeenergies.com) Site: Storr Residence 1965 Sunburst Drive Vail, CO 81657 System Layout: Single Panel = 5.32ft tall X 3.66ft wide Panel Arrangement: 2 rows of 8; all panels orientated in the portrait position and mounted flush to the west facing roof. Holy Cross electric meter located on the north west corner of the garage. Production meter adjacent to net meter; inverter in garage directly behind the net meter. Minimum Designed Temperature: -40°F Maximum Ambient Design Temperature: 140°F All AC wiring to be completed by project Colorado licensed master electrician All DC wiring to be overseen by NABCEP certified installer Net Meter and main service disconnect Prod Meter 10/12/18 Page 2 of 4 8/8/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Calculations 5.6kW System Size (STC) • 16 Solaria PowerXT350 solar panels @ 350 watts • 16 SolarEdge P370 Optimizers • 1 SolarEdge SE5000H-US inverter (1 string of 16) (8-18 allowable) • Fixed array tilt angle: 9.46º • Array azimuth: 160º (where 180º is south) • Estimated annual power production: 7,267kWh Maximum PV System Voltage: 690.7 Voc = 47.1V/module 47.1V x 1 module = 47.1V Temperature correction factor 690.7(A) Temperature Coefficient (Voc) = -0.30%/°C (-65C° x (-.0030C°)) = .195% ((.195% x 47.1V) x 1 panels) + 47.1V = 56.28 Maximum PV Source Circuit (String) Current: 690.8 (A)(1) Isc = 9.49A 9.49A x 1.25 = 11.86A Maximum PV Output Circuit (Array) Current: 690.8 (A)(2) SE5000H-US inverter limit 13.5A combined string Inverter Output Circuit Current: 690.8 (A)(3) 21A @ 240V 10/12/18 Page 3 of 4 8/8/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com Conductor Sizing Pass Thru Box from Optimizers to Inverter (combined strings): SE5000H-US inverter limit 13.5A combined string 13.5A x 1.25 = 16.9A #10 THWN-2 Table 310.16 40A (90ºC column, see note 240.4(D)) No temperature correction factor No conduit fill adjustment Inverter to Production meter and Service Panel: Nameplate maximum continuous output current: 21A @ 240V 21A x 125% =25A 210.19 (A)(1) #10 THWN-2 Table 310.16 30A (75ºC column) No temperature correction factor No conduit fill adjustment Overcurrent Protection Device 30A two pole breaker Per Manufacturer Specification Conductors may be oversized for voltage drop 10/12/18 Page 4 of 4 8/8/2018 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com SolarEdge SE5000H-US Inverter w/ Integrated Disconnect NEMA 3R Max AC Output: 21A @ 240V With ARC Fault Protection & Rapid Shutdown compliant DC Grounding Electrode Conductor solid bare #6 Cu, per NEC 250.66(C) Service Panel NEMA 3R Inside garage Line Diagram Storr Residence 1965 Sunburst Drive Vail, CO 81657 5.6kW Utility Interactive Photovoltaic System Modules: 16 X Solaria PowerXT 350W Voc = 47.1V Isc = 9.49A Optimizers: 16 SolarEdge P370 1 String X 16 Modules Inverter: SolarEdge SE5000H-US Operating Voltage: 380V Operating Current: 9.38A Max System Voltage: 480V Max Output Current: 21A Tilt Angle: 9.46° Array Azimuth: 160° Production: 7,267kWh/yr Notes: - See Calculation Sheet for conductor sizing. - All conductors are copper unless otherwise noted. - Inverter listed (UL-1741) to de- energize upon loss of utility voltage per NEC 690.61. - Inverter has integral ground-fault protection per NEC 690.5 - 240V 1 Phase Service Panel rating of 200A (bus rating 200 amp and 200 Main disconnect) to accommodate 40A (PV) + 200A (Main) = 240A supply (up to 120% of connected power sources from installations per NEC 705(D)(2)(3)(b)~5' ¾” C EMT/PVC/ other 3 #10 THWN-2 1 #10 G THWN-2 Backfeed Breaker 30A 2P 240v ~100' ¾” C/EMT 2 #10 THWN 1 #10 Ground 2 #10 PV Wire 1# 6G Bare Cu Conductors in Free Air Array mounted on roof 16 Solaria PowerXT 350w Solar Panels 16 SolarEdge P370 DC Optimizers Pass-Thru Box Located on house roof 1 2 3 16... ~5' ¾” C EMT/PVC/ other 3 #10 THWN-2 1 #10 G THWN-2 30A Located adjacent to net meter Located inside garage directly behind net meter 10/12/18 About Solaria Established in 2000, The Solaria Corporation has created one of the industry’s most respected IP portfolios, with over 100 patents encompassing materials, processes, applications, products, manufacturing automation and equipment. Headquartered in Fremont, California, Solaria has developed a technology platform that unlocks the potential of solar energy allowing it to be ubiquitous and universally accessed. Achieving up to 19.4% efficiency, Solaria PowerXT solar modules are one of the highest power modules in the residential solar market. Compared to conventional modules, Solaria PowerXT modules have fewer gaps between the solar cells; this leads to higher power and superior aesthetics. Solaria PowerXT residential modules are manufactured with black backsheet and frames, giving them a striking appearance. Developed in California, Solaria’s patented cell cutting and module assembly takes processed solar wafers and turns them into PowerXT solar modules. The process starts by creating a highly reliable PowerXT cell where busbars and ribbon interconnections are eliminated. Solaria then packages the cells into the PowerXT solar module, reducing inactive space between the cells. All of the above leads to an exceptionally efficient solar module produced in a cost effective manner. Higher Efficiency, Higher Power Solaria PowerXT modules achieve up to 19.4% efficiency; conventional modules achieve 15% – 17% efficiency. Solaria PowerXT modules are one of the highest power modules available. Lower System Costs Solaria PowerXT modules produce more power per square meter area. This reduces installation costs due to fewer balance of system components. Improved Shading Tolerance Sub-strings are interconnected in parallel, within each of the four module quadrants, which dramatically lowers the shading losses and boosts energy yield. Improved Aesthetics Compared to conventional modules, Solaria PowerXT modules have a more uniform appearance and superior aesthetics. Durability and Reliability Solder-less cell interconnections are highly reliable and designed to far exceed the industry leading 25 year warranty. The Solaria Corporation 6200 Paseo Padre Parkway, Fremont, CA 94555 P: (510) 270-2500 www.solaria.com Copyright © 2017 The Solaria Corporation Product specifications are subject to change without notice. Rev 1E 12-21-2017 Solaria PowerXT®-350R-PD | Solaria PowerXT®-345R-BD Solaria PowerXT® | Residential 10/12/18 The Solaria Corporation 6200 Paseo Padre Parkway, Fremont, CA 94555 P: (510) 270-2500 www.solaria.com Copyright © 2017 The Solaria Corporation Product specifications are subject to change without notice. Rev 1E 12-21-2017 Solaria PowerXT®-350R-PD Solaria PowerXT®-345R-BD Performance at STC (1000W/m2, 25° C, AM 1.5) Solaria PowerXT- 340R-BD 345R-BD 345R-PD 350R-PD Max Power (Pmax) [W] 340 345 345 350 Efficiency [%] 18.8 19.1 19.1 19.4 Open Circuit Voltage (Voc) [V] 46.9 47.1 46.9 47.1 Short Circuit Current (Isc) [A] 9.36 9.40 9.46 9.49 Max Power Voltage (Vmp) [V] 38.6 38.9 38.5 38.8 Max Power Current (Imp) [A] 8.79 8.88 8.93 9.02 Power Tolerance [%] -0/+3 -0/+3 -0/+3 -0/+3 Performance at NOCT (800W/m2, 20°C Amb, Wind 1 m/s, AM 1.5) Max Power (Pmax) [W] 252 255 255 259 Open Circuit Voltage (Voc) [V] 44.1 44.3 44.1 44.3 Short Circuit Current (Isc) [A] 7.58 7.61 7.66 7.69 Max Power Voltage (Vmp) [V] 35.5 35.8 35.4 35.7 Max Power Current (Imp) [A] 7.03 7.10 7.15 7.22 Temperature Characteristics NOCT [ºC] 45 +/-2 Temp. Coeff. of Pmax [% / ºC] -0.39 Temp. Coeff. of Voc [% / ºC] -0.29 Temp. Coeff. of Isc [% / ºC] 0.04 Design Parameters Operating temperature [ºC] -40 to +85 Max System Voltage [V] 1000 Max Fuse Rating [A] 15 Bypass Diodes [#] 4 Mechanical Characteristics Cell Type Monocrystalline Silicon Dimensions (L x W x H) 1621mm x 1116mm x 40mm Weight 21 kg / 46 lbs Glass Type / Thickness AR Coated, Tempered / 3.2mm Frame Type Anodized Aluminum Cable Type / Length 12 AWG PV Wire (UL) / 1000mm Connector Type Amphenol H4 (MC4 compatible) Junction Box IP67 / 4 diodes Front Load (UL 1703) 5400 Pa / 113 psf Rear Load (UL 1703) 3600 Pa / 75 psf Certifications / Warranty Certifications UL 1703/IEC 61215/IEC 61730/CEC Fire Type (UL 1703) 1 Power & Product Warranty 25 years* * Warranty details at www.solaria.com Packaging Stacking Method Horizontal / Palletized Pcs / Pallet 25 Pallet Dims (L x W x H) 1685 x 1150 x 1230 mm Pallet Weight 590 kg / 1300 lbs Pallets / 40-ft Container 28 Pcs / 40-ft Container 700 Authorized Dealer 0 1 2 3 4 5 6 7 8 9 10 0 5 10 15 20 25 30 35 CURRENT (A)VOLTAGE (V) 1000W/m2 800W/m2 600W/m2 400W/m2 200W/m2 40 45 50 40 [63.8in±.2] 1621mm±5 [1in] 25mm [5.8in]148mm [5.8in]148mm [43.9in±.2] 1116mm±5 [1in] 25mm [35.43in] 900mm [15.04in] 382mm 4.5mm [0.18in] THRU ALL 4X GROUND 'A' 7mm [0.276in] X 10mm [0.394in] 4X MOUNTING SLOTS 'B' A B NEGATIVE (-) 1000 (3.3 ft) POSITIVE (+) 1000 (3.3 ft) B B B A AA MOUNTING SLOT [.3in]7mm [.4in] 10mm [1.57in] 40mm [.07in] 1.7mm [1.38in]35mm [.39in] 10mm IV Curves (350W Module) 10/12/18 POWER OPTIMIZERSolarEdge Power Optimizer Module Add-On For North America P300 / P320 / P370 / P400 / P405 Up to 25% more energy Superior efficiency (99.5%) Mitgates all types of module mismatch losses, from manufacturing tolerance to partal shading Flexible system design for maximum space utlizaton Fast installaton with a single bolt Next generaton maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety PV power optimization at the module-level www.solaredge.usUSA - CANADA - GERMANY - ITALY - FRANCE - JAPAN - CHINA - AUSTRALIA - THE NETHERLANDS - UK - ISRAEL - TURKEY - SOUTH AFRICA - BULGARIA - INDIA 10/12/18 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 03/2017 V.02. Subject to change without notice. (2) For detailed string sizing informaton refer to: htp://www.solaredge.com/sites/default/files/string_sizing_na.pdf. (3) It is not allowed to mix P405 with P300/P370/P400/P600/P700 in one string. P300 (for 60-cell mod- ules) P320 (for high-power 60-cell modules) P370 (for higher-power 60 and 72-cell modules) P400 (for 72 & 96-cell modules) P405 (for thin film modules) INPUT Rated Input DC Power(1) 300 320 370 400 405 W Absolute Maximum Input Voltage (Voc at lowest temperature)48 60 80 125 Vdc MPPT Operatng Range 8 - 48 8 - 60 8 - 80 12.5 - 105 Vdc Maximum Short Circuit Current (Isc) 10 11 10.1 Adc Maximum DC Input Current 12.5 13.75 12.63 Adc Maximum Efficiency 99.5 % Weighted Efficiency 98.8 % Overvoltage Category II OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Maximum Output Current 15 Adc Maximum Output Voltage 60 85 Vdc OUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) Safety Output Voltage per Power Optmizer 1 Vdc STANDARD COMPLIANCE EMC FCC Part15 Class B, IEC61000-6-2, IEC61000-6-3 Safety IEC62109-1 (class II safety), UL1741 RoHS Yes INSTALLATION SPECIFICATIONS Maximum Allowed System Voltage 1000 Vdc Compatble inverters All SolarEdge Single Phase and Three Phase inverters Dimensions (W x L x H) 128 x 152 x 27.5 / 5 x 5.97 x 1.08 128 x 152 x 35 / 5 x 5.97 x 1.37 128 x 152 x 50 / 5 x 5.97 x 1.96 mm / in Weight (including cables) 630 / 1.4 750 / 1.7 845 / 1.9 gr / lb Input Connector MC4 Compatble MC4 / Amphenol AH4 MC4 Compatble Output Wire Type / Connector Double Insulated; MC4 Compatble Double Insulated; MC4 / Amphenol AH4 Double Insulated; MC4 Compatble Output Wire Length 0.95 / 3.0 1.2 / 3.9 m / ſt Operatng Temperature Range -40 - +85 / -40 - +185 ˚C / ˚F Protecton Ratng IP68 / NEMA6P Relatve Humidity 0 - 100 % (1) Rated STC power of the module. Module of up to +5% power tolerance allowed. SolarEdge Power Optimizer Module Add-On for North America P300 / P320 / P370 / P400 / P405 PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(2)(3) SINGLE PHASE HD-WAVE SINGLE PHASE THREE PHASE 208V THREE PHASE 480V Minimum String Length (Power Optmizers)8 10 18 Maximum String Length (Power Optmizers)25 25 50 Maximum Power per String 5700 (6000 with SE7600H-US)5250 6000 12750 W Parallel Strings of Different Lengths or Orientatons Yes 10/12/18 INVERTERSwww.solaredge.us 12-25 Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US / SE7600H-US / SE10000H-US Optimized installation with HD-Wave technology Specifically designed to work with power optmizers Record-breaking efficiency Fixed voltage inverter for longer strings Integrated arc fault protecton and rapid shutdown for NEC 2014 and 2017, per artcle 690.11 and 690.12 UL1741 SA certfied, for CPUC Rule 21 grid compliance Extremely small High reliability without any electrolytc capacitors Built-in module-level monitoring Outdoor and indoor installaton Optonal: Revenue grade data, ANSI C12.20 Class 0.5 (0.5% accuracy) 10/12/18 SE3000H-US SE3800H-US SE5000H-US SE6000H-US SE7600H-US SE10000H-US OUTPUT Rated AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 VA Max. AC Power Output 3000 3800 @ 240V 3300 @ 208V 5000 6000 @ 240V 5000 @ 208V 7600 10000 VA AC Output Voltage Min.-Nom.-Max. (183 - 208 - 229) - 3 - 3 - - Vac AC Output Voltage Min.-Nom.-Max. (211 - 240 - 264) 3 3 3 3 3 3 Vac AC Frequency (Nominal) 59.3 - 60 - 60.5(1) Hz Maximum Contnuous Output Current 208V - 16 - 24 - - A Maximum Contnuous Output Current@240V 12.5 16 21 25 32 42 A GFDI Threshold 1 A Utlity Monitoring, Islanding Protecton, Country Configurable Thresholds Yes INPUT Maximum DC Power 4650 5900 7750 9300 11800 15500 W Transformer-less, Ungrounded Yes Maximum Input Voltage 480 Vdc Nominal DC Input Voltage 380 400 Vdc Maximum Input Current 208V - 9 - 13.5 - - Maximum Input Current@240V 8.5 10.5 13.5 16.5 20 27 Adc Max. Input Short Circuit Current 45 Adc Reverse-Polarity Protecton Yes Ground-Fault Isolaton Detecton 600k Sensitvity Maximum Inverter Efficiency 99 99.2 % CEC Weighted Efficiency 99 % Nightme Power Consumpton < 2.5 W ADDITIONAL FEATURES Supported Communicaton Interfaces RS485, Ethernet, ZigBee (optonal), Cellular (optonal) Revenue Grade Data, ANSI C12.20 Optonal(2) Rapid Shutdown - NEC 2014 and 2017 690.12 Automatc Rapid Shutdown upon AC Grid Disconnect STANDARD COMPLIANCE Safety UL1741, UL1741 SA, UL1699B, CSA C22.2, Canadian AFCI according to T.I.L. M-07 Grid Connecton Standards IEEE1547, Rule 21, Rule 14 (HI) Emissions FCC Part 15 Class B INSTALLATION SPECIFICATIONS AC Output Conduit Size / AWG Range 3/4” minimum / 20-4 AWG DC Input Conduit Size / # of Strings / AWG Range 3/4” minimum / 1-2 strings / 14-6 AWG 3/4” minimum / 1-3 strings / 14-6 AWG Dimensions with Safety Switch (HxWxD) 17.7 x 14.6 x 6.8 / 450 x 370 x 174 21.3 x 14.6 x 7.3 / 540 x 370 x 185 in / mm Weight with Safety Switch 22 / 10 25.1 / 11.4 26.2 / 11.9 38.8 / 17.6 lb / kg Noise < 25 <50 dBA Cooling Natural Convecton Natural convecton Operatng Temperature Range -13 to +140 / -25 to +60(3) (-40˚F / -40˚C opton)(4) ˚F / ˚C Protecton Ratng NEMA 3R (Inverter with Safety Switch) Single Phase Inverter with HD-Wave Technology for North America SE3000H-US / SE3800H-US / SE5000H-US / SE6000H-US/ SE7600H-US / SE10000H-US (1) For other regional setngs please contact SolarEdge support(2) Revenue grade inverter P/N: SExxxxH-US000NNC2(3) For power de-ratng informaton refer to: htps://www.solaredge.com/sites/default/files/se-temperature-deratng-note-na.pdf(4) -40 version P/N: SExxxxH-US000NNU4 © SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein are trademarks of their respective owners. Date: 05/2018/V01/ENG NAM. Subject to change without notice. 10/12/18 1 2 3 4 1 2 3 4 1 2 3 4 .90in .54in .40in Scale 1:1 1.50in .75in M8-1.25 Threaded Hole .55in .31in .38in 1.63in 1.13in 1.50in (2x) 3/8-24 Threaded Hole .31in .38in 1.63in 1.13in .50in (2x) 3/8-24 Threaded Hole 1.50in 1.50in Left RightFront Top Back S-5-U M8-1.25 Threaded Through Hole Kati Kadakas 4/11/2016 DATEDRAWN BY DRAWING NO. ® TITLE EST. WEIGHT: SCALE: SUPPLIED HARDWARE: EST ASSEMBLY WEIGHT: MATERIAL: METAL ROOF INNOVATIONS, LTD. 8655 TABLE BUTTE RD COLORADO SPRINGS, CO 80908 719-495-0518 719-495-0045(FAX)The Right Way! S-5! S-5-U U11-B-16-D 6061 T6 Al 1:1 0.373 lbs M8-1.25 x 16 mm HEX Bolt FOR STANDING SEAM SPECIFIC MECHANICAL LOAD TEST INFORMATION AND CLAMP INSTALLATION INFORMATION PLEASE VISIT: WWW.S-5.COM General Notes: (2x) 3/8-24 x .800" Setscrews1. S-5-U Clamp 2. M8-1.25 SS Hex Flange Bolt (13mm Socket) 3. 3/8-24 SS Round Point Setscrew (3/16 Hex Drive) 4. Example roof Clamp: Setscrew: Bolt: 0.304 lbs 0.0170 lbs 0.0345 lbs S-5!® PRODUCTS ARE PROTECTED BY MULTIPLE U.S. AND FOREIGN PATENTS. VISIT OUR WEBSITE AT WWW.S-5.COM FOR COMPLETE INFORMATION ON PATENTS AND TRADEMARKS. 10/12/18 Technical Datasheets R A HILTI GROUP COMPANY Pub 110818-1td V1.0 August 2011 SolarMount Technical Datasheet SolarMount Module Connection Hardware .................................................................. 1 Bottom Up Module Clip.................................................................................................1 Mid Clamp ....................................................................................................................2 End Clamp ....................................................................................................................2 SolarMount Beam Connection Hardware ......................................................................3 L-Foot ...........................................................................................................................3 SolarMount Beams ..........................................................................................................4 • Bottom Up Clip material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear Anodized • Bottom Up Clip weight: ~0.031 lbs (14g) • Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents • Assemble with one ¼”-20 ASTM F593 bolt, one ¼”-20 ASTM F594 serrated flange nut, and one ¼” flat washer • Use anti-seize and tighten to 10 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory • Module edge must be fully supported by the beam * NOTE ON WASHER: Install washer on bolt head side of assembly. DO NOT install washer under serrated flange nut Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, Φ Tension, Y+ 1566 (6967) 686 (3052) 2.28 1038 (4615) 0.662 Transverse, X± 1128 (5019) 329 (1463) 3.43 497 (2213) 0.441 Sliding, Z± 66 (292) 27 (119) 2.44 41 (181) 0.619 SolarMount Module Connection Hardware SolarMount Bottom Up Module Clip Part No. 302000C Bottom Up Clip Beam Washer (hidden..see note*)Nut Bolt Dimensions specified in inches unless noted Y X 1 10/12/18 Technical Datasheets R A HILTI GROUP COMPANY • End clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • End clamp weight: varies based on height: ~0.058 lbs (26g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single end clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble with one Unirac ¼”-20 T-bolt and one ¼”-20 ASTM F594 serrated flange nut • Use anti-seize and tighten to 10 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory • Modules must be installed at least 1.5 in from either end of a beam • Mid clamp material: One of the following extruded aluminum alloys: 6005-T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • Mid clamp weight: 0.050 lbs (23g) • Allowable and design loads are valid when components are assembled according to authorized UNIRAC documents • Values represent the allowable and design load capacity of a single mid clamp assembly when used with a SolarMount series beam to retain a module in the direction indicated • Assemble mid clamp with one Unirac ¼”-20 T-bolt and one ¼”-20 ASTM F594 serrated flange nut • Use anti-seize and tighten to 10 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third- party test results from an IAS accredited laboratory Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, Φ Tension, Y+ 2020 (8987) 891 (3963) 2.27 1348 (5994) 0.667 Transverse, Z± 520 (2313) 229 (1017) 2.27 346 (1539) 0.665 Sliding, X± 1194 (5312) 490 (2179) 2.44 741 (3295) 0.620 SolarMount Mid Clamp Part No. 302101C, 302101D, 302103C, 302104D, 302105D, 302106D Mid Clamp Serrated Flange Nut Bolt Y X Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Loads lbs (N) Resistance Factor, Φ Tension, Y+ 1321 (5876) 529 (2352) 2.50 800 (3557) 0.605 Transverse, Z± 63 (279) 14 (61) 4.58 21 (92) 0.330 Sliding, X± 142 (630) 52 (231) 2.72 79 (349) 0.555 SolarMount End Clamp Part No. 302001C, 302002C, 302002D, 302003C, 302003D, 302004C, 302004D, 302005C, 302005D, 302006C, 302006D, 302007D, 302008C, 302008D, 302009C, 302009D, 302010C, 302011C, 302012C Beam End Clamp Bolt Serrated Flange Nut Beam Dimensions specified in inches unless noted Dimensions specified in inches unless noted Y X 2 10/12/18 Technical Datasheets R A HILTI GROUP COMPANY SolarMount Beam Connection Hardware • L-Foot material: One of the following extruded aluminum alloys: 6005- T5, 6105-T5, 6061-T6 • Ultimate tensile: 38ksi, Yield: 35 ksi • Finish: Clear or Dark Anodized • L-Foot weight: varies based on height: ~0.215 lbs (98g) • Allowable and design loads are valid when components are assembled with SolarMount series beams according to authorized UNIRAC documents • For the beam to L-Foot connection: • Assemble with one ASTM F593 ⅜”-16 hex head screw and one ASTM F594 ⅜”serrated flange nut • Use anti-seize and tighten to 30 ft-lbs of torque • Resistance factors and safety factors are determined according to part 1 section 9 of the 2005 Aluminum Design Manual and third-party test results from an IAS accredited laboratory NOTE: Loads are given for the L-Foot to beam connection only; be sure to check load limits for standoff, lag screw, or other attachment method SolarMount L-Foot Part No. 304000C, 304000D Beam L-Foot Bolt Serrated Flange Nut Dimensions specified in inches unless noted Y X Applied Load Direction Average Ultimate lbs (N) Allowable Load lbs (N) Safety Factor, FS Design Load lbs (N) Resistance Factor, Φ Sliding, Z± 1766 (7856) 755 (3356) 2.34 1141 (5077) 0.646 Tension, Y+ 1859 (8269) 707 (3144) 2.63 1069 (4755) 0.575 Compression, Y- 3258 (14492) 1325 (5893) 2.46 2004 (8913) 0.615 Traverse, X± 486 (2162) 213 (949) 2.28 323 (1436) 0.664 3 10/12/18 Technical Datasheets R A HILTI GROUP COMPANY Properties Units SolarMount SolarMount HD Beam Height in 2.5 3.0 Approximate Weight (per linear ft) plf 0.811 1.271 Total Cross Sectional Area in² 0.676 1.059 Section Modulus (X-Axis) in3 0.353 0.898 Section Modulus (Y-Axis) in3 0.113 0.221 Moment of Inertia (X-Axis) in4 0.464 1.450 Moment of Inertia (Y-Axis) in4 0.044 0.267 Radius of Gyration (X-Axis) in 0.289 1.170 Radius of Gyration (Y-Axis) in 0.254 0.502 1.316 .387 2.500 .750 SLOT FOR T-BOLT OR 1 4" HEX HEAD SCREW 2X SLOT FOR BOTTOM CLIP SLOT FOR 38" HEX BOLT SLOT FOR T-BOLT OR 14" HEX HEAD SCREW 1.385 SLOT FOR BOTTOM CLIP SLOT FOR 38" HEX BOLT 1.875 3.000 1.207 1.728 SolarMount Beams Part No. 310132C, 310132C-B, 310168C, 310168C-B, 310168D 310208C, 310208C-B, 310240C, 310240C-B, 310240D, 410144M, 410168M, 410204M, 410240M SolarMount Beam SolarMount HD Beam Dimensions specified in inches unless noted Y X Y X 4 10/12/18