Loading...
HomeMy WebLinkAboutB18-0386_Approved Plans_1537903114.pdfSITZMARK LODGE POOL/SPA DECK REFURBISHMENT 183 GORE CREEK DR VAIL, COLORADO 81657 C COPYRIGHTVictor MarkDonaldsonArchitects All RightsReservedPOOL/SPA DECKREFURBISHMENT 183 GORE CREEK DRVAIL, CO 8165709/25/18 C COPYRIGHTVictor MarkDonaldsonArchitects All RightsReservedPOOL/SPA DECKREFURBISHMENT 183 GORE CREEK DRVAIL, CO 8165709/25/18 C COPYRIGHTVictor MarkDonaldsonArchitects All RightsReservedPOOL/SPA DECKREFURBISHMENT 183 GORE CREEK DRVAIL, CO 8165709/25/18 C COPYRIGHTVictor MarkDonaldsonArchitects All RightsReservedPOOL/SPA DECKREFURBISHMENT 183 GORE CREEK DRVAIL, CO 8165709/25/18 C COPYRIGHTVictor MarkDonaldsonArchitects All RightsReservedPOOL/SPA DECKREFURBISHMENT 183 GORE CREEK DRVAIL, CO 8165709/25/18 C COPYRIGHTVictor MarkDonaldsonArchitects All RightsReservedPOOL/SPA DECKREFURBISHMENT 183 GORE CREEK DRVAIL, CO 8165709/25/18 C COPYRIGHTVictor MarkDonaldsonArchitects All RightsReservedPOOL/SPA DECKREFURBISHMENT 183 GORE CREEK DRVAIL, CO 81657Max 4" openings New guardrails shall match existing guardrails in material, color and general design. Height may change as required by building code. 09/25/18 C COPYRIGHTVictor MarkDonaldsonArchitects All RightsReservedPOOL/SPA DECKREFURBISHMENT 183 GORE CREEK DRVAIL, CO 8165709/25/18 ELECTRICAL ONE-LINE DIAGRAM NO SCALE 42kAlC 1200A, 120/208V, 3P, 4W PANEL MAIN HOUSE PANEL X29,800AICTO UTILITY TRANSFORMER X<10K AIC (4#4/0 AL, #4 AL G)2"C X23,800AIC 1200/3 KRP-C (3)1200A KAISER PANEL X<10K AIC (4#1/0 AL, #4 AL G)2"C 200/3 FRN-R (3)200A 100/3 FRN-R (3)100A (7) 200/3 (3) 100/3 (2) 60/3 HIGHEST DEMAND PER HOLY CROSS IS 128KW OR 355 AMPS, JAN 2011 METER #95697 SPA PANEL X <10K AIC 100/2 FRN-R (2)100A NEW WORK IS CLOUDED M P1 M P2 M P3 LVL1 POOL & SPA NOTES 1. COORDINATE GROUNDING WITH POOL/SPA CONTRACTOR TO ENSURE ALL METAL PARTS WITHIN 5'-0" HORIZONTALLY OF POOL/SPA INSIDE WALLS ARE GROUNDED AND APPROPRIATE BONDING LOCATIONS ARE ESTABLISHED. ALL ELECTRICAL EQUIPMENT ASSOCIATED WITH THE POOL/SPA INCLUDING PANELBOARDS, CONDUIT, JUNCTION BOXES, MOTORS, ETC. SHALL BE GROUNDED PER NEC 680.6. 2. UNDERGROUND WIRING SHALL NOT BE PERMITTED UNDER THE POOL/SPA OR THE AREA EXTENDING 5'-0" HORIZONTALLY FROM THE INSIDE WALLS OF THE POOL/SPA UNLESS NECESSARY TO SUPPLY ASSOCIATED EQUIPMENT IN THIS AREA PERMITTED BY CODE. REF NEC 680.10. 3. ALL OUTLETS SUPPLYING POOL/SPA EQUIPMENT SHALL BE GFI PROTECTED. REF NEC 680.21(C). 4. CIRCULATION/SANITATION MOTOR RECEPTACLES SHALL BE LOCATED A MINIMUM OF 10'-0" FROM THE INSIDE WALLS OF THE POOL/SPA. ALL OTHER RECEPTACLES SHALL BE A MINIMUM OF 6'-0" FROM THE INSIDE WALLS OF THE POOL/SPA, MEASURED BY CORD LENGTH. ALL 120V RECEPTACLES BEYOND 6'-0" AND WITHIN 20'-0" OF THE POOL/SPA SHALL HAVE GFI PROTECTION. DISTANCES MEASURED BY CORD LENGTH. REF NEC 680.22(A). 5. NO LIGHTS SHALL BE ALLOWED UNDER 5'-0" AFG WITHIN 5'-0" HORIZONTALLY FROM THE INSIDE WALLS OF THE POOL/SPA. LIGHTS UNDER 5'-0" AFG BEYOND 5'-0" AND WITHIN 10'-0" HORIZONTALLY SHALL HAVE GFI PROTECTION. REF NEC 680.22(B). 6. REFERENCE NEC 680.26 FOR DETAILED BONDING REQUIREMENTS. PROVIDE #8 GROUNDING CONDUCTORS TO BOND THE FOLLOWING, BUT NOT LIMITED TO THE FOLLOWING: 6.1. CONDUCTIVE POOL SHELLS 6.2. POOL/SPA PERIMETER SURFACE WITHIN 3'-0" HORIZONTALLY FROM INSIDE WALLS OF POOL/SPAS 6.3. ALL METALLIC COMPONENTS OF THE POOL/SPA STRUCTURE 6.4. WET NICHE LIGHT FIXTURE SHELL/MOUNTING BRACKETS 6.5. ASSOCIATED METAL FITTINGS ATTACHED TO THE POOL/SPA STRUCTURE 6.6. ALL METAL PARTS OF POOL/SPA EQUIPMENT AND ELECTRICAL EQUIPMENT 6.7. ALL FIXED METAL PARTS SUCH AS METAL SHEATHED CABLES/RACEWAYS, METAL PIPING/AWNINGS/FENCES/WINOW AND DOOR FRAMES, ETC. 6.8. POOL WATER WITH A MINIMUM CONDUCTIVE SURFACE AREA OF 9 SQ. IN. 7. FOR ALL SPA INSTALLATIONS OTHER THAN SINGLE-FAMILY DWELLINGS, A CLEARLY LABELED EMERGENCY SHUTOFF SWITCH SHALL BE PROVIDED WITHIN SIGHT OF AND ADJACENT TO THE SPA, A MINIMUM OF 5'-0" AWAY FROM THE SPA, TO SHUT OFF ALL CIRCULATION AND JET PUMPS. REF NEC 680.41. 8. AUTOFILL REQUIRES 1/2" FRESH WATER LINE WITH BACKFLOW AND FREEZE PROTECTION LOCATED AT EQUIPMENT. 9. INTELLITOUCH LOAD CENTER SHIPPED LOOSE AND MOUNTED REMOTELY BY GC A MINIMUM OF 5FT FROM WATER LINE. SPA-1,3 M TO SPA-5,7 SPA-9,11 SPA-13 ELECTRICAL CONTRACTOR TO REVIEW ON SITE AND DETERMINE BEST WAY TO ADD A 100/2 SWITCH. EITHER REWORK EXISTING SWITCHES WITHIN GEAR TO ADD A 100/2 SWITCH OR PROVIDE LUGS AT BUS BAR TO PROVIDE FEED TO AN EXTERNAL 100/2 DISCONNECT. of www.aec-vail.comaPO Box 8489, 40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620Mechanical, Electrical & Lighting Design ServicesArchitectural Engineering ConsultantsTelephone: 970-748-8520ceDrawn By: Checked By: DATE: ISSUE: AEC PROJECT #: SITZMARK LODGE183 GORE CREEK DRVAIL, CO 8165718044An Office with LEED™ Accredited Professionals8/31/18 PERMIT <$) 51* '.'%64+%#. 10'Ä.+0'  2#0'. 5%*'&7.'5 5%#.' 010' '   09/25/18 GENERAL NOTES: 1. NEW LED LIGHTS SHALL BE HOME-RUN TO EXISTING POOL LIGHTING CIRCUIT. EC TO VERIFY EXISTING CIRCUITS AND CONNECT LIGHTS TO EXISTING CIRCUITS. 2. PROVIDE POOL AND SPA GROUNDING PER GROUNDING NOTES PER SHEET E1.1. REFERENCE SHEET E1.1. SHEET DETAIL NOTES: EXISTING RECEPTACLE TO BE RE-USED AND PLACE IN ACCORDANCE WITH NEC 680.22. EC TO VERIFY AND RE-USE EXISTING CIRCUIT. 1 NEW LED NEW LED NEW LED NEW LED NEW LED NEW LED NEW LED NEW LED NEW LED NEW LED M M M SPA-1,3 SPA-5,7 SPA-9,11 PANEL SPA M TO SPA-13 1 WIRING CONNECTIONS BETWEEN LOAD CENTER AND EQUIPMENT COMPONENTS MADE BY ELECTRICIAN. LOAD CENTER REQUIRES CLEARANCE FOR PANEL ACCESS. TYPICALL 36" IN FRONT OF THE SUB PANEL WITH 30" OF WORKSPACE MUST BE CLEAR OF OBSTRUCTION. GC IS RESPONSIBLE FOR PROVIDING PROPER ACCESS PER LOCAL CODE REQUIREMENTS. WP GFI EMEREGENCY SHUT OFF SIWTCH FOR SPA. TO BE LOCATED IN THE FIELD. of www.aec-vail.comaPO Box 8489, 40801 US Hwy 6 & 24, Ste 214, Avon, Colorado, 81620Mechanical, Electrical & Lighting Design ServicesArchitectural Engineering ConsultantsTelephone: 970-748-8520ceDrawn By: Checked By: DATE: ISSUE: AEC PROJECT #: SITZMARK LODGE183 GORE CREEK DRVAIL, CO 8165718044An Office with LEED™ Accredited Professionals8/31/18 PERMIT <$) 51* 52# 219'4  5;56'/5 2.#0 5%#.'   žÄ '   NORTH BASEMENT POWER & SYSTEMS PLAN SCALE: 1/4" = 1'0" 09/25/18 09/25/18 All high strength bolting and welds to have special inspection 09/25/18