Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B18-0401_Approved Documents_1538493854.pdf
75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspections: inspections@vailgov.com Construction B18-0401 Issued: 10/02/2018 TOWN OF VAIL Property Information Address: 4682 MEADOW DR F22 (210112419022 F22) ( 210112419022 ) Unit #: F22 Parcel Number: 210112419022 Legal Description: DESC: BLDG F PHASE III Subdivision: MOUNTAIN MEADOW CONDOMINIUMS Unit: 22 Contacts Contact Type: Applicant Full Name: Debbie Cary Address:PO Box 810, 825-A Chambers Ave PO Box 810, 825-A Chambers Ave 825- A Chambers Ave Eagle, CO 81631 Phone: 9703282699 Contact Type: Property Owner Full Name: KRISCHER, DAVID S. - NELSON, MARGARET E. Address: Phone: None Contractor Contractor Type: Mechanical Company: R & H Mechanical LLC State License #: Phone: 970-328-2699 Project Information Project Name: Krischer Residence 2018 Project Description: Remove Old Boiler.Install New WHN155 Boiler with Outdoor Air Sensor,Y Strainer,Grundfos Pump, Neutrlizer & Condensate Line to New Sanitary Trap in Crawlspace.New Primary/Secondary Manifold with Extra Taps. Fees Paid Account #: 110-0000.31060.00 - Construction Use Tax Fee Fee Amount:$84.54 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$300.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$75.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Total Paid:$464.54 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. PERMIT FEE RECEIPT Case # B18-0401 Date Printed: 10/02/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B18-0401 Status: Approved Permit Number: Date Started: 09/12/2018 Permit Type: Construction Subcases Multi-Family Lot Number: Property: 4682 MEADOW DR F22 (210112419022 F22) (210112419022) Contacts Contact Type: Applicant Company Name: R and H Mechanical, LLC Full Name: Debbie Cary Address: PO Box 810, 825-A Chambers Ave PO Box 810, 825-A Chambers Ave 825-A Chambers Ave Eagle, CO 81631 Email: debbiec@randhmechanical.com Contact Type: Property Owner Full Name: KRISCHER, DAVID S. - NELSON, MARGARET E. Address: Permit Fees Fee Information Account Amount Construction Tax 110-0000.31060.00 $84.54 Permit Fee 001-0000.31111.00 $300.00 Will Call Fee 001-0000.31128.00 $5.00 Payment Information Date Paid Payment Type Amount Permit Fee 10/02/2018 Credit Card $300.00 Paid By: - Notes: visa-david young Will Call Fee 10/02/2018 Credit Card $5.00 Paid By: - Notes: visa-david young Construction Tax 10/02/2018 Credit Card $84.54 Paid By: - Notes: visa-david young FEE TOTAL $389.54 AMOUNT PAID $389.54 BALANCE DUE $0.00 10/02/2018 - 9:15:43 AM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657 1 / 1 Lochinvar.com HIGH EFFICIENCY RESIDENTIAL BOILERS CON·X·US® REMOTE CONNECT CAPABLE LOCH-N-LINK ® USB DRIVE SETUP 3 SETPOINTS WITH OUTDOOR RESET CURVES DHW RECIRCULATION PUMP CONTROL 7 MODELS: 55,000 – 399,999 BTU/HR TOP AND BOTTOM WATER CONNECTIONS** UP TO 10:1 TURNDOWN RATIO** WALL MOUNT DESIGN 95% AFUE Efficiency** See back page for efficiency by model MONEY-SAVING 95% EFFICIENCY AND EASIER THAN EVER TO INSTALL The KNIGHT wall mount fire tube boiler allows for a more flexible installation with top and bottom water connections**. Multiple water connection locations add flexibility by allowing boiler connections to be as close as possible to the system piping, reducing installation cost, complexity and the amount of piping needed for a job. The KNIGHT fire tube boiler operates with low pressure drop. The design incorporates a small volume of water in the heat exchanger allowing the boiler to be installed in a primary/secondary or a full-flow piped system. There is no need to change the piping to accommodate the boiler. The boiler adapts to the system. This flexibility allows for a faster, more cost-effective boiler upgrade. ** Not included on WHN400 UPDATED SMART SYSTEM™ CONTROL Newest version of the SMART SYSTEM allows for easier setup and navigation of parameters. New features include DHW recirculation pump control, LOCH-N-LINK® USB programming, larger user interface, cascade leader redundancy and modulation factor for fine tuning aggressiveness. 10:1 TURNDOWN RATIO OPTIMIZES PERFORMANCE Modulation turndown up to 10:1 means the firing rate automatically changes as the heat load varies. A WHN111 KNIGHT boiler fires at its maximum 110,000 Btu/hr rate when load is highest, then “turns down” to as low as 10% (11,000 Btu/hr) as load decreases. A modulating boiler runs smoothly and efficiently, without frequent on/off cycling. ** Not included on WHN400 SUPERIOR DIRECT-VENTING FLEXIBILITY KNIGHT boilers can be installed with direct-vent air intake and exhaust runs up to 100 equivalent feet, using PVC, CPVC, polypropylene or AL29-4C stainless steel vent pipe. 6 Inputs from 55,000 to 285,000 Btu/hr. See KNIGHT fire tube boiler literature (KHN) for more details. FLOOR-STANDING FIRE TUBE MODELS AVAILABLE BOILER CONTROL, FROM ANYWHERE. From wherever you are, the CON·X·US option lets you use any Internet-capable device to link up with the SMART SYSTEM on an unlimited number of KNIGHT boilers. With CON·X·US, you’re always in touch and in control. Optional CON·X·US control board is sold separately. COLOR-CODED LCD DISPLAY ® REMOTE CONNECT Blue Screen Normal system operation Yellow Screen Maintenance due shows installer name & number Red Screen Lockout mode THE ULTIMATE IN BOILER CONTROL & MONITORING The industry’s most advanced boiler control system now includes the CON·X·US Remote Connect option and LOCH-N-LINK USB Programming feature. See back cover for a complete list of SMART SYSTEM functions and features. LOCH-N-LINK EASY USB PROGRAMMING Use a USB drive to name, store and easily manage multiple proven parameter sets. Quickly upload them via the front panel port, reducing installation and programming time. > Do regular CON·X·US checks for all your KNIGHT customers, and let them know you’re monitoring their boiler’s performance. > Adjust setpoints, domestic hot water, reset curves, pump delays and more, using the CON·X·US interactive display. > Status alerts via text or e-mail lets you know when a KNIGHT boiler needs attention. M N O L B FLUE COIN VENT AIR VENT F E H I J K G D INLET OUTLET LOW VOLTAGE ELECTRICAL CONNECTIONS HIGH VOLTAGE ELECTRICAL CONNECTIONS CONDENSATE DRAIN A C Information subject to change without notice. Change “N” to “L” for LP gas models. The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15. Lochinvar should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc. The ratings have been determined under the provisions governing forced draft burners. KNIGHT Boiler Dimensions and Specifications WHN-05 (Reprint WHN-05 6/17) © Lochinvar, LLC - ASB - 10M 10/17 - Printed in U.S.A. iPhone and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. Android and Google are trademarks of Google Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Google Play is a service mark of Google Inc. Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com KNIGHT Boiler Dimensions and Specifications Top Right Bottom Input Heating Net AHRIModel Max. Min. AFUE % Capacity Rating Number MBH MBH MBH MBH MBH WHN056 55 8.3 95 51 44 WHN086 85 8.5 95 79 69 WHN111 110 11 95 102 89 WHN156 155 15.5 95 144 125 WHN200 199.9 19.9 95 185 161 WHN286 285 28.5 95 264 229 WHN400 399 80 94.4* 377# 328 Smart System Features > Smart System Digital Operating Control Multi-Color Graphic LCD Display w/Navigation Dial, Soft Keys and Loch-N-Link USB programming > Three Boiler Setpoint Temperature Inputs Plus Domestic Hot Water Prioritization > Built-in Cascading Sequencer for up to 8 Boilers, with Cascade Redundancy Multiple Size Boiler Cascade Lead Lag Efficiency Optimization Front End Loading Capability > Outdoor Reset Control with Outdoor Air Sensor Programmable for Three Reset Temperature Inputs > Programmable System Efficiency Optimizers SH Night Setback DHW Night Setback Anti-Cycling Outdoor Air Reset Curve Ramp Delay Modulation Factor Control Boost Temperature & Time > Four Pump Control System Pump with Parameter for Continuous Operation Boiler Pump with Variable Speed Control Domestic Hot Water Pump Domestic Hot Water Recirculation > Domestic Hot Water Prioritization DHW tank piped with priority in the boiler loop DHW tank piped as a zone in the system with the pumps controlled by the SMART SYSTEM DHW Modulation Limiting Separately Adjustable Space Heat/DHW Switching Times > Building Management System Integration 0-10 VDC Input to Control Modulation or Setpoint 0-10 VDC Modulation Rate Output 0-10 VDC Input to Enable/Disable Call for Heat > Access to BMS Settings through Graphic LCD Display > High-Voltage Terminal Strip 120 VAC / 60 Hertz / 1 Phase Power Supply Three Sets of Pump Contacts > Low-Voltage Terminal Strip DHW Recirculation Pump Start/Stop 24 VAC Device Relay Proving Switch Contacts Flow Switch Contacts Alarm on Any Failure Contacts Runtime Contacts DHW Thermostat Contacts 3 Space Heat Thermostat Contacts System Sensor Contacts DHW Tank Sensor Contacts Outdoor Air Sensor Contacts Cascade Contacts 0-10 VDC BMS External Control Contact 0-10 VDC Boiler Rate Output Contacts 0-10 VDC Variable Speed System Pump Signal Input 0-10 VDC Signal to Control Variable Speed Boiler Pump Modbus Contacts > Time Clock > Data Logging Hours Running, Space Heating Hours Running, Domestic Hot Water Ignition Attempts Last 10 Lockouts > Maintenance Reminder Custom Maintenance Reminder with Contractor Contact Information Installer Ability to De-activate Service Reminder > Low-Water Flow Safety Control & Indication > Password Security > Customizable Freeze Protection Parameters Standard Features > 95% DOE AFUE Efficiency (56-286) > Modulating Burner with up to 10:1 Turndown** Direct Spark Ignition Low NOx Operation > ASME Stainless Steel Heat Exchanger 30 PSI ASME Relief Valve > Top and bottom water connections (MNPT)** > Vertical & Horizontal Direct Vent PVC, CPVC, Polypropylene or SS Venting up to 100 feet > SMART SYSTEM Control > Condensate Trap > Other Features Automatic Reset High Limit Adjustable High Limit w/Manual Reset Boiler Circulating Pump Zero Clearances to Combustible Materials 15-Year Limited Warranty (See Warranty for Details) 5-Year Limited Parts Warranty Optional Equipment CON·X·US Remote Connectivity Modbus Communication BACnet MSTP Flow Switch Low-Water Cutoff w/Manual Reset & Test Alarm Bell Concentric Vent Kit Condensate Neutralization Kit BMS Gateway to LON or BACnet IP Multi-Temperature Loop Control Sidewall Vent Termination Wireless Outdoor Sensor LP Gas Conversion Kit > Firing Codes M9 Standard Construction M7 California Code **10:1 Turndown ratio and top and bottom water connections are not included on WHN400. WHN400 operates with a 5:1 turndown. A B C D E F G H I J K L M N O Gas Water Air Vent Shipping Conn. Conn. Inlet Size Wt. (lbs.) 33-1/4” 18-1/2” 16” 11-3/4” 9” 3-1/2” 3-3/4” 1-1/2” 3” 6-1/8” 7-1/4” 3-3/4” 6-1/2” 4-1/2” 8-1/2” 1/2” 1” 2” 2” 139 33-1/4” 18-1/2” 16” 11-3/4” 9” 3-1/2” 3-3/4” 1-1/2” 3” 6-1/8” 7-1/4” 3-3/4” 8-1/2” 4-1/2” 8-1/2” 1/2” 1” 2” 2” 142 33-1/4” 18-1/2” 19” 14-1/2” 8-3/2” 5” 7-3/4” 1-1/8” 12-3/8” 4-1/4” 11-1/4” 3” 5-1/4” 5-1/8” 10” 1/2” 1” 3” 3” 159 33-1/4” 18-1/2” 19” 14-1/2” 8-1/2” 5” 7-3/4” 1-1/8” 12-3/8” 4-/14” 11-1/4” 3” 5-1/4” 5-1/8” 10” 1/2” 1” 3” 3” 166 33-1/4” 18-1/2” 19” 14-1/2” 11” 6-1/4” 7-3/4” 1-1/2” 12-3/8” 4-1/4” 9-1/2” 3” 5-1/4” 5-1/2” 10-3/4” 1/2” 1-1/4” 3” 3” 175 33-1/4” 18-1/2” 21-3/4” 16-1/2” 11-1/8” 6-1/4” 7-3/4” 1-1/2” 12-3/8” 16-3/8” 12-1/4” 3-1/8” 5-1/4” 4” 15-1/8” 1/2” 1-1/4” 3” 3” 184 35-1/2” 25” 21-3/4” 17-1/2” 12-1/2” 9-1/4” 9-1/2” 2-1/4” 13-1/4” 21-1/2” 9” 4-3/4” 4” 22-1/2” 3-3/4” 3/4” 1-1/2” 4” 4” 213 **Not included on WHN400 *Thermal Efficiency% # Gross Output MBH Stainless Steel Indirect Water Heaters 12 Squire Models to Choose From - 6 Standard Models from 30 to 119 Gallons - 6 Solar Models from 65 to 119 Gallons 316L Passivated Stainless Steel Tank 316L High Capacity Stainless Steel Coil Fully Welded Construction Lochinvar.com Laser Cut Precision A CNC laser uses Programmable Logic Controls to precisely cut the Squire Indirect Water Heater’s tank shell out of 14 gauge 316L stainless steel to a tolerance of .01 inch. 2 The Squire Stainless Steel Indirect Water Heater -- with 12 models to choose from in capacities from 30-119 gallons, we are sure to have the right size indirect water heater to fit your application. Squire features important enhancements that our customers will recognize and benefit from such as a welded and passivated stainless steel tank and heat exchanger, two-inch thick, high-density insulating foam, and best of all it is designed, engineered and assembled in America. LASER Cut Precision Robotic Welder Passivated for Protection - a new Class of Water Heater Tank Cylinder Roller The computer controlled tank cylinder rolling machine ensures that the 316L stainless steel is transformed into a geometrically perfect cylinder. Coil Winder Straight tubes are rolled by a seven axis coil winder and turned into a precise, round coil used in the indirect water heater to transfer the BTU’s from the heat source to the potable water stored in the tank. Robotic Welder This state of the art six axis programmable robotic welder uses computer guidance to accurately weld the stainless steel fittings to the tank. Hydrostatic Leak Test After welding, the tank is hydrostatically pressure tested to ensure quality conformance. Passivation Process Each tank is subjected to a soaking spray of nitric acid. This treatment washes away any iron that was left behind during the welding process and re-establishes the oxide level of the stainless steel to ensure corrosion resistance. By removing iron from the welded surfaces, the Squire is less susceptible to corrosion brought on by aggressive water. Jacket and Foam The dent resistant polypropylene jacket and ABS caps are attached to the tank assembly, and then high density foam is added using a high pressure dispensing system to provide insulation that will keep the heat where it belongs, in the water. The result is a tank that is jacketed and evenly foam insulated with standby losses as low as 0.5°F per hour.Foam Insulation Process Stainless Steel Tank Manufacturing 3 316L Passivated Stainless Steel Tank 316L Stainless Steel material is used for the tank interior for superior durability and long life. The rust prohibitive characteristics of this material make it the perfect material to resist the corrosive tendencies of domestic water. The passivation process consists of a treatment method that enhances and increases the superior corrosion resistance of stainless steel. 316L High Capacity Stainless Steel Coil The Squire’s 316L Stainless Steel heating coil efficiently transfers high volumes of BTU’s from the heat source to the domestic water with high first hour delivery capability. Designed, Engineered and Assembled in the USA A 100% stainless steel indirect water heater built in the USA, the Squire is completely assembled in Lebanon, Tennessee. Outstanding Features Inside Look Stainless Steel SIT Indirect How it Works Combine the Knight Heating Boiler with the Squire Indirect for the perfect combination for your application. Dent resistant polypropelene jacket* Temperature & pressure relief valve Sensor well 316L Stainless Steel coil High density foam insulation Cold water inlet Boiler water outlet Boiler water inlet The Squire uses the power and efficiency of the building’s heating boiler or solar array to generate domestic hot water for showers, dishwashing, clothes washing or any potable hot water demand. The efficiency of the heating boiler could be as much as 20% higher than a direct-fired tank-type water heater. So, why not use that efficiency to “indirectly” provide hot water for all potable applications? By using the Squire to indirectly heat the domestic water, you eliminate the additional gas line, electrical connections and vent ducts needed with direct-fired tank-type water heaters. Six Standard Models from 30 to 119 Gallons The highest quality indirect water heater in the market also has one of the widest ranges of gallon capacities. With 6 models covering gallon capacities from 30 to 119 gallons the Squire is one of the broadest lines available. Six Solar Models from 65 to 119 Gallons With three dual coil models for solar heating in conjunction with a heat source and three models with a solar coil and an electric element the Squire line of water heaters has a model to fit any residential or light duty commercial solar application. 100% Stainless Steel Construction Squire Water Heaters are constructed with Stainless Steel materials that are highly resistant to corrosion that can result from poor water quality. *SET models feature metal jacket Fully Welded Construction Lochinvar utilizes state of the art, highly accurate robotic welding equipment that results in a fully welded construction method that requires no gaskets or mechanical sealing methods. Gaskets and seals are the weak point of any water storing appliance, therefore Lochinvar’s advanced design eliminates this potential failure point. Factory Supplied Tank Sensor (SIT and SDT only) A tank sensor with built in temperature limit is standard equipment on all sizes. This sensor accurately monitors the water temperature and sends a call for heat when the tank temperature drops below the desired setpoint. This sensor is 100% compatible and can be directly connected with Lochinvar’s line of KNIGHT or Cadet Heating Boilers. T&P Relief Valve Supplied with the unit in the carton. (shipped loose) High Density CFC/HCFC Free Polyurethane Foam Two inches of R-13.4 High Density Polyurethane foam yields the lowest standby losses in the industry. Attractive Rust Resistant Jacket Resistant to scratches and dents, the Squire will maintain its classic high quality appearance for years. Limited Lifetime Warranty* Lochinvar believes that the Squire is the best built Indirect Water Heater on the market, we have a Limited Lifetime warranty to prove it. *SIT models only Solar Indirect with SET Electric Back-upSolar Indirect with SDT Dual Coil Squire Indirect Water Heaters with a single coil and an electric element are designed to collect heat from a solar array and transfer the collected heat into the stored water by way of the indirect coil which is located in the lower portion of the tank. An electric element, which is controlled by a factory supplied thermostat, is positioned in the top half of the tank to ensure ample hot water even at times when the solar array is not capable of collecting the heat required by the DHW demand. Squire Indirect Water Heaters with a dual coil design have a coil in the lower portion of the tank to transfer heat from a solar array to the water that is stored in the tank. An additional coil in the upper portion of the tank will transfer heat from a back-up boiler into the water. This will ensure that the tank has ample hot water even at times when the solar array cannot generate enough heat to suitably heat the tank. Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt. (lbs.) SIT030 39-1/2” 20” 32-1/4” 21-3/4” 8-1/4” 3” 1” 1” 79 SIT040 55-3/4” 20” 48-1/2” 25-1/4” 8-1/4” 3” 1” 1” 105 SIT050 48” 24” 39-3/4” 24-1/2” 9-1/4” 3-3/4” 1” 1” 131 SIT065 60” 24” 52-1/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 147 SIT080 69-1/2” 24” 61-3/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 177 SIT119 68-1/4” 28” 60-1/4” 31-3/4” 9-1/4” 3-1/4” 1-1/2” 1” 213 Heat Source Standby First Continuous 1st Hour Min. Flow Friction Model Capacity Water Volume Loss Draw Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (°F/Hr) Gals. (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SIT030 27 1.1 1.5 24 160 184 99,000 14.0 3.9 SIT040 40 1.6 0.9 27 181 208 115,000 14.0 4.5 SIT050 52 1.7 0.9 45 210 255 133,000 14.0 5.3 SIT065 67 1.9 0.7 65 263 328 154,000 14.0 5.7 SIT080 82 2.1 0.6 74 266 340 160,000 14.0 5.7 SIT119 113 3.2 0.5 109 308 418 199,999 14.0 6.5 Performance data is based on IWH-TS1 test results. All ratings are based on 180°F boiler water temperature with incoming cold water at 58°F and a Delta T of 77°F. Includes tank sensor for use with KNIGHT Heating Boiler. Optional thermostat available for use with other boiler models. SIT MODELS All models standard with a Lifetime Limited Warranty against tank failure. All parts are warranted for one year. Five year limited tank warranty on all models when installed in a commercial application. Stainless Steel Indirect SIT Models Dimensions and Specifications TRIM AREAThe “Hot Water Outlet” connection is Female NPT. All other connections are Male NPT. Solar Stainless Steel Indirect Dimensions and Specifications SIT-02 (Reprint SIT-02 5/17) A D G H I FROMPANEL TOPANEL COLD WATERINLET SOLARSENSORWELL Domestic Coil Model Water Connection Shipping Number A B D E F G H I Conn. Size Wt. (lbs.) SDT065 60” 24” 52-1/4” 47-1/4” 33-3/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 158 SDT080 69-1/2” 24” 61-3/4” 53-3/4” 40-1/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 188 SDT119 68-1/4” 28” 60-1/4” 54-1/2” 37-1/2” 31-3/4” 9-1/4” 3-1/4” 1-1/2” 1” 224 Heat Boiler Heat Standby Continuous 1st Hour Min. Flow Friction Model Capacity Source Water Source Water Loss Delivery Delivery Coil Load Rate Loss Number (Gallons) (Gallons) (Gallons) (°F/Hr) (GPH) (Gallons) (Btu/Hr) (GPM) (Ft. Hd.) SDT065 66 2.1 1.7 0.7 175 205 128,000 14.0 3.4 SDT080 79 2.1 1.7 0.6 175 208 128,000 14.0 3.4 SDT119 110 3.2 2.6 0.5 251 301 181,000 14.0 4.9 Performance data based on incoming cold water at 50°F and a Delta T of 77°F. Delivery ratings for boiler coil only. Includes tank sensor for use w/ KNIGHT Heating Boiler. Domestic Coil Model Water Connection Shipping Number A B D G H I Conn. Size Wt. (lbs.) SET065 60” 24” 52-1/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 149 SET080 69-1/2” 24” 61-3/4” 28” 9-1/4” 3-1/4” 1-1/2” 1” 179 SET119 68-1/4” 28” 60-1/4” 31-3/4” 9-1/4” 3-1/4” 1-1/2” 1” 215 Electric Electric Heat Source Standby Continuous 1st Hour Model Capacity Water Loss Delivery Delivery Number (Gallons) (Gallons) (°F/Hr) (GPH) (Gallons) SET065 67 1.9 0.7 24 54 SET080 81 2.1 0.6 24 57 SET119 113 3.2 0.5 24 75 All SET models: 4500w 240v 1 phase. SDT Models Dimensions and Specifications SET Models Dimensions and Specifications SDT Models SET Models SET & SDT MODELS All models standard with a 5 Year Limited Warranty against tank failure. All parts are warranted for one year. *SET models only The “Hot Water Outlet” connection is Female NPT. All other connections are Male NPT. Lochinvar, LLC 300 Maddox Simpson Parkway Lebanon, Tennessee 37090 P: 615.889.8900 / F: 615.547.1000 Lochinvar.com ASB 5M-1/18–Printed in U.S.A.