HomeMy WebLinkAboutB18-0411 approved plans.pdffown of Vail REVIEWED FOR CODE COMPLIANCE fown of Vall OFFICE COPY Dcsig~~~~ VAIL I DENVER (970) 376-7396 PO Box 2411 Avon, CO 81620 JOB 5024.00 SCALE 1/4" = 1'-0" SHEET NO. ______ _ OF ____ _ CALCULATED BY DMB DATE_9/7/18 _ CONNECT TO EXISTING 3/4" CA PIPE AT THIS POINT Date:_ q --'Z'f-l t:.6 By:.. A~ ::......1 Cm1e:----t~~~~~t:o.-__,-----CHECKED BY DATE. ____ _ CONSULTING ENGINEERS SUBJECT_ Vail Marriott Laundry Equipment Replacement ,.-EXISTING COMPRESSED AIR DDtll'.------::-"'.:,.;"..•_ .... :-"": .... :-' -.:-..... :------11 ---..ww,....t-"l'i ~~·11·~~~•f"""'l±!'.I!" . .,a~w:::::-~._,.~ ... +,-jrf'.t-11ouTLET AND 3/4' PIPE ON NORTH WALL TO REMAIN. ~~~~~Ec~;~~~SED 11 11 I . IW AIR LINE WITH 3/4" COPPER OR IRON PIPE 1051b Washer 1051b Washer 651b Washer 1201b Dryer 1201b Dryer EXISTING 1" RUBBER COMPRESSED AIR FROM BOILER ROOM. TRANSITION 1" RUBBER TO 1" COPPER OR IRON PIPE. EXTEND EXISTING 1" COMPRESSED AIR PIPING WITH 1" COPPER OR IRON PIPE TO FOLDER --11 1" CA (EXISTING) .-.... CA \ . . • ~ J 14" ROUND DRYER EXHAUST. SEE SHEET M-3 FOR MANIFOLD 10" ROUND DRYER EXHAUST TRANSITION DUCT TO EXISTING 16" ROUND DRYER EXHAUST RISER. PROVIDE CLEAN OUT AT BASE OF RISER, TYP. G EXISTING WALL AND DOOR TO BE <' I !RELOCATED ~ >< 11 I 1RELOCATED NEW WALLAND DOOR (IN RED) EXISTING 72 X 36 OSA RISER. 1-4'.' 11 I l1NSTALL PLENUM TRANSITION TO Conveyor (2) 36 X 15 GRILLS OPEN TO LAUNDRY ROOM. EXISTING 1-1/2" GAS STUB-OUTS AT CEILING, TYPICAL OF ---....a..___j3_ EXTEND GAS PIPING TO TO EACH DRYER. SEE GAS PIPING DIAGRAM, SHEET M-3 TRANSITION 1" Folding , COMPRESSED AIR PIPING r-· '" 1 'i1'"e I CA---L Folder I ·Ill I II 1~gL~~~~~L~~T66~T;:c~~gN LAUNDRY ROOM MECHANICAL PLAN 1' NORTH SHEET M-2 ~ ~ ~ ~ ' (::tJ STACK NEW NON-FUSED WASHER DISCONNECTS VERTICALLY ON WALL, TYP OF 3. RECONNECT WASHERS TO EXISTING WASHER CB'S IN PANEL "LAUNDRY", 3 #12 & #12G, 3/4"C. REPLACE EXISTING 4' FLUORESCENT FIXTURES WITH NEW 4'LED VAPOR PROOF FIXTURES. EXTEND/ REPLACE WIRING AND CONDUITS AS REQUIRED. RECONNECT NEW 1051b Washer Dc~ig~~~-~ RELOCATED CO DETECTOR 1051b Washer E1 651b Washer CONSULTING ENGINEERS RELOCATED HEAT DETECTOR 1201b Dryer e 120llb Dry~r VAIL I DENVER (970) 376-7396 PO Box 2411 Avon, CO 81620 B qpR 751b Dryer II JOB 5024.00 SCALE 1/4" = 1'-0" SHEET NO .. ______ _ OF ____ _ CALCULATED BY DMB DATE_9/7/18 _ CHECKED BY DATE ____ _ SUBJECT_ Vail Marriott Laundry Equipment Replacement ..-NEW NON-FUSED DRYER DISCONNECTS ON WALL, TYP. ,aJ::!..---';OF 3. RECONNECT DRYERS TO EXISTING DRYER CB'S IN PANEL ,1'LAUNDRY" 3#12 & #12G, 3/4"C RELOCATED DOOR MAG HOLD OPEN, TYP OF 2. ~ I I EXISTING WALL AND DOOR TO BE I .~ .RELOCATED . '--....-~ . ....-....-....-....-....-....-....-___. ~ ,._ I .;?< \ II ::;:J !RELOCATED NEW WALLAND I DOOR (IN RED) • E9" ~Ill ... ~ -· II IRELOCiTJ EXIT SIGN FIXTURES TO EXISTING~ ... i I I .,,. >~ LIGHTING CCT, TYP. -< I II !RELOCATED STROBE \ • . , I \ 1 ... ·. --•I "" ronveyo&1 I II !RELOCATED RECEPTACLE, I I 1------t_ I :::t:S:I----·TYPICALOF4. I t _ _ HD Folding Table R LAUNDRY ROOM ELECTRICAL PLAN Folder 1' NORTH R NEW NON-FUSED DISCONNECT FOR FOLDER, 3#12 & 1#12 G, 3/4"C TO LAUNDRY-13,15,17 SHEET E-2 Dcsig~5~~ CONSULTING ENGINEERS VAIL I DENVER (970} 376-7396 PO Box 2411 Avon, CO 81620 II JOB 5024.00 SCALE 1/4" = 1'-0" SHEET NO .. ______ _ OF ____ _ CALCULATED BY DMB DATE_9/7/18 _ CHECKED BY DATE. ____ _ SUBJECT_ Vail Marriott Laundry Equipment Replacement ' REMOVE DISCONNECT AND CIRCUIT TO 11 I 9DISHWASHER. LABEL , , ~ ~' W ABANDONNED CB AS "' SPARE IN PANEL REMOVE WASHER DISCONNECT AND CIRCUIT TO PANEL, TYP OF 3 J-BOX FROM I I If a n: ' 0 PREVIOUSLY L----Ut~-------J.'----.J.'-------7> REMOVED FIXTURE TO BE REUSED FOR NEW FIXTURE. SEE SHEET E-2. REMOVE 4' FLUORESCENT FIXTURES. EXISTING CIRCUIT TO BE REUSED, TYPICAL OF 6 • t r-I ~ RELOCATE EXISTING EXIT SIGN RELOCATE EXISTING HEAT DETECTOR [---HH-••H-i r n -I ® 8n::; I I, B RELOCATE CO DETECTOR. RELOCATE STROBE a1 1 11 IREMovE wALL MOUNTED FLUORESCENT FIXTURE AND CIRCUIT, TYP OF 2. I II !REMOVE DRYER ~ r 1m I Y ! I I co rdJtlg:~g~~NTEg~~~~L. I . NOTES: 1. SEE SHEET E-2, ELECTRICAL FLOOR PLAN FOR RELOCATED DEVICE LOCATIONS 2. REMOVE ALL CONDUIT AND WIRING FOR DEMOLISHED CIRCUITS. 3. ALL FIXTURES, DEVICES, EQUIPMENT, ETC. ARE EXISTING U.NO. --.1 ' LAUNDRY ROOM ELECTRICAL DEMO PLAN 1' NORTH SHEET E-3 -·-t . ........... -~-----.1 . ,. \ ' • ~ J • .. • t \ • 1051b Washer 1051b Washer Desi~~2.g CONSULTING ENGINEERS 651b Washer 1120 lb Dryer PATCH FLOOR TO MATCH EXISTING -1201b Dryer VAIL I DENVER (970) 376-7396 PO Box 2411 Avon, CO 81620 --i 1: ~ r JOB 5024.00 SHEET NO. CALCULATED BY CHECKED BY SUBJECT SCALE 1/4" = 1' -0" OF DMB DATE~9lli1.a DATE PATCH/EXTEND DRYWALL CEILING SYSTEM TO MATCH EXISTING LAUNDRY ROOM F.R CEILING IN SHADED AREA. """ 11 ~-!REMOVE EXISTING DOOR ASSEMBLY AND WALLS. ~ 11 I 1EXTEND EXISTING FIRE SERVICE CORRIDOR RATED CORRIDOR WALL SYSTEM TO MATCH EXISTING TO STRUCTURE. ~ 1 ·""""" , 1 1 rEXTEND EXISTING 2· x 2· > CEILING TILE SYSTEM IN SHADED AREA. NEW 5' DOUBLE LEAF DOOR ASSEMBLY (3' + 2' LEAF). DOOR FIRE RATING TO MATCH EXISTING SERVICE CORRIDOR DOOR RATINGS. * l ~..-'("" ~"'~-..-r-o.l~~ ~ ~ti\) cl~. Folding Table LAUNDRY ROOM FLOOR PLAN fOldef] t NORTH SHORTEN HAND RAIL TO ACCOMMODATE NEW CORNER POINT OF WALL MODIFY RAIL AS REQUIRED . SHEET A-1 l bi~~~--~ CONSULTING ENGINEERS VAIL I DENVER (970) 376-7396 PO Box 2411 Avon, CO 81620 JOB 5024.01 SCALE None SHEET NO. ______ _ OF _____ _ CALCULATED BY_,D=-M~B ___ _ DATE 9/7/18 CHECKED BY ______ _ DATE ----- SUBJECT Vail Marriott Laundry Equipment Replacement EXHAUST MANIFOLD DIAGRAM TRANSITION 14" TO + EXISTING 16" RISER I < NOTE: PROVIDE DUCT CLEAN OUT ACCESS PANEL AT BASE OF EXHAUST RISERS. 14" \ 1 ti'' ..,. \t." w:~~~ ~·-\ 8" 10" t f 75 POUND 120 POUND GAS SERVICE METER& PRV STATION TO BOILER PLANT DRYER DRYER GAS PIPING DIAGRAM 2" G---. NOTE: PROVIDE GAS COCK AND DRIP LEG AT CONNECTIONS TO DRYERS. LAUNDRY ROOM CEILING G----.. 1-1/4" G ---1-1/4" EXISTING GAS PIPING ABOVE CEILING EXISTING 1-1/2" STUB OUT AT CEILING, TYP OF3 CONNECT NEW 1-1/4" TO EXISTING CEILING STUB OUT & EXTEND TO NEW DRYER, TYP. 1-1/4" ---G--.. I 120 POUND DRYER 75 POUND DRYER SHEET M-3 VAIL I DENVER JOB 5024.01 SCALE None NRG ~ (970) 376-7396 SHEET NO. 1 OF PO Box 2411 CALCULATED BY DMB DATE 9L7L18 Design Build. Inc. Avon, CO 81620 CHECKED BY DATE CONSULTING ENGINEERS SUBJECT Vail Marriott Laundry EguiQment ReQlacement ONE LINE DIAGRAM HOLY CROSS ENERGY TRANSFORMER T k------- MOP -4000 A 208Y/120 VOLT, 3 PHASE, 4 WIRE SERVICE ENTRANCE ( 2000 A BUSS 4000 A MAIN BUSS/METER SECTION "-c:J..-+-..,-~,..--,---,,-.,......t-r~.-..,--.~.-.-- 2000 A 2000AF D(200A 200AF 2000 A FULLY CROSS BUSSED SECTIONS (4) 3/0 & G, 2"C NOTES; HCE METER #910275 1. ALL EQUIPMENT IS EXISTING U.N.O. SERVICE fQWf.B DEMAND SUMMARY HOLY CROSS ENERGY METER # 910275 PEAK DEMAND 0.412 KW X 400 MULTIPLIER = 164.8 KW PEAK DEMAND 456.5 AMPS AT 208Y/120 VOLT, 3 PHASE EXISTING 2000 AMP SERVICE LOADED TO 23% OF CAPACITY MOP HAS ADEQUATE CAPACITY TO SERVE NEW LAUNDRY PANEL "LP" LOADS fANE!.. "LP" POWER PEMANP SUMMARY PANEL LP 225 A PANEL FED BY 200 A FEEDERS AND FUSES 208Y/120 VOLT, 3 PHASE LOADS IN PANEL: EXISTING CONDITIONS PANEL LOAD (SEE PANEL SCHEDULE SHEET E-5) LOADS TO BE REMOVED J..QAQS IQ aE ADDED NEW LOAD TOTAL ON PANEL (SEE PANEL SCHEDULE SHEET E-5) 81.9A -6.6A +18.4 A 93.7 A PANEL "LP" HAS ADEQUATE CAPACITY FOR ADDITIONAL LAUNDRY ROOM LOADS. SHEET E-4 VAIL I DENVER {970) 376-7396 PO Box 2411 Avon, CO 81620 JOB 5024.01 SHEET N0. __ .::.1 ____ _ CALCULATED BY ___ D __ M _____ B __ _ CHECKED BY ______ _ SCALE None OF ____ _ DATE 9/7/18 DATE ____ _ CONSULTING ENGINEERS SUBJECT Vail Marriott Laundry Equipment Replacement PANEL "LP" EXISTING CONDITIONS PANEL LP 208 Y/ 120 VOLT 3PH 4 WIRE 225 AMPERE MAINMLO : 225 AMPERE BUS -- LOCATION LAUNDRY ROOM MOUKTING SURFACE A.l.C. 42,000 .... a: LOAD aFCUT CFO.IT BUS CFO.IT CflClXr LOAD .... a: -w 1Yf£ LOAD DESCRIPTION BREAKER BREAKER 1Yf£ LOAD DESCRIPTION -w :::i"' :::i"' (J ::;; LINEA LINEB LINEC URIM URIM LINE A LINE B LINEC ~::;; !E :::i POLE TRIP A B C TRIP POLE (J z LM/EJA/S LM/EJAIS -:::i (J z 1 1200 M WASHER#1 3 + 3 LM WASHER#2 1200 2 3 1200 + 1200 4 5 1200 20 + 20 1200 6 7 360 A LAUNDRY RECEPT 1 20 + 20 1 E STAIRWELL HEATER 600 8 9 180 BAR PEPSI RECEPT 1 20 + 20 1 A LAUNDRYRECEPT 180 10 11 50 KEY BOX 1 20 + 20 1 LAUNDRYRECEPT 180 12 13 SPARE 1 20 + 20 1 LAUNDRYRECEPT 180 14 15 SPARE 1 20 + 20 1 SPARE 16 17 SPARE 1 20 + 3 M WASHER 1000 18 19 1200 A DISHWASHBI 2 + 1000 20 21 1200 so + 30 1000 22 23 SPARE 1 20 + 3 M WASHER#3 1200 24 25 760 M DR)l;R #1 3 + 1200 26 27 760 + 20 1200 28 29 760 20 + 20 1 SPN1E 30 31 760 M DRYER#2 3 + 20 1 SPN1E 32 33 760 + SPN1E 34 35 760 20 + 2 A BN1 ICE S90 36 37 760 M DR)l;R #3 3 + 20 1 A 590 38 39 760 + 2 A BN1 COFFEE 12SO 40 41 760 20 + 30 1250 42 S040 4860 3530 SUBTOTALS 4770 4830 5420 CIRCUIT TYPE L=LIGHTING, R..RECEPTACLE, M·MOTOR, LM=LARGEST MOTOR LINE TOTALS 9810 9690 8950 DESCRIPTION: E-EOUIPMENT, A=APPLIANCE, S-SUBFEED PANEL NEC ADDER 4SO 300 300 NOTES: FEED THAU LOAD 0 0 0 1 EXISTING CONDITIONS TOTAL VM'H 10260 9990 9250 2 REMOVE DISHWASHER LOAD, CCT 19,21 LINEMf'S 86 83 77 TOTAL KVALOAD 29.5 FEEDERMf'S 81 .9 PANEL "LP" NEW CONDITIONS' PANEL LP 208 Y/ 120 VOLT 3PH 4 WIRE 225 AMPERE MAINMLO : 225 AMPERE BUS -- LOCATION LAUNDRY ROOM MOUKTING SURFACE A.1.C. 42,000 .... a: LOAD CFO.IT CFO.IT BUS CFO.IT CRlif LOAD .... a: 5~ 1Yf£ LOAD DESCRIPTION BREAKER BREAKER 1Yf£ LOAD DESCRIPTION - w :::> ID (J :::; LINEA LINES LINEC URIM URIM LINE A LINE B LINt: C (J :::; !E :::i POLE TRIP A B C TRIP POLE !E :::i (J z LMIE/AIS LMIE/AIS (J z 1 1200 M WASHER#1 3 + 3 LM WASHERt2 1685 2 3 1200 + -1685 4 5 1200 20 + 20 1685 6 7 360 A LAUNDRY RECEPT 1 20 + 20 1 E STAIRWELL HEATER 600 8 9 180 BAR PEPSI RECEPT 1 20 + 20 1 A LAUNDRY RECEPT 180 10 11 50 KEY BOX 1 20 + 20 1 A LAUNDRYRECEPT 180 12 13 960 E FOlDER 3 + 20 1 A LAUNDRY RECEPT 180 14 15 960 + 20 1 SPARE 16 17 960 20 + 3 M WASHER 1000 18 19 SPARE 2 + 1000 20 21 so + 30 1000 22 23 SPN1E 1 20 + 3 M WASHERt3 1685 24 25 760 M DR)l;R #1 3 + -1685 26 27 760 + 20 1685 28 29 760 20 + 20 1 SPARE 30 31 845 M DRYER#2 3 + 20 1 SPARE 32 33 845 -+ SPN1E 34 35 845 -20 + 2 A BAR ICE 590 36 37 845 M DRYERt3 3 + 20 A S90 38 39 845 -+ 2 A BAR COFFEE 12SO 40 41 845 . 20 + 30 12SO 42 4970 4790 4660 SUBTOTALS S740 S800 6390 CIRCUIT TYPE L·LIGHTING, R=RECEPTACLE, M=MOTOR, LM·LARGEST MOTOR .Ll LINE TOTALS 10710 10S90 110SO DESCRIPTION: E-EOUIPMENT, A=APPLIANCE, S·SUBFEEO PANEL NEC ADDER S71 421 421 NOTES: ~ {_y~ FEED THRU LOAD 0 0 0 1 NEW CONFIGURATION TOT M'H 11281 11011 11471 2 REPLACE WASHER #2 & #3, REUSE EXISTING CB'S . a,;<~ INEMIPS 94 92 96 ~'DJ 3 REPLACE DRYER #2 & 13, REUSE EXISTING CB'S VJ r7i,\<> ~ TOT PL KVALOAD 33.8 SHEET 4 ADO TOWEL FOLDER, NEW C8 , FEEDER Mf'S 93.7 ~'V 1'2~ ~xrn ~. E-5 .~ \ } .,J /,.# ~~ ~ ' ,~ s~~) ~AL~~ JOB 5024.01 ~ SCALE None (970) 376-7396 SHEET NO. 1 OF PO Box 2411 CALCULATED BY DMB DATE 9L7[18 Avon, CO 81620 CHECKED BY DATE CONSULTING ENGINEERS SUBJECT Vail Marriott Laundry Equipment Replacement SCOPE OF WORK Furnish all materials and labor required to execute this work as indicated on the drawings and as specified, as necessary for complete operating systems. Provide mechanical and electrical system repair, replacement and refurbishment services as necessary to accommodate the replacement of the existing laundry equipment. Scope to include: • Remove existing washer/extractors and dryers. Replace with new equipment and reconnect utilities. o Relocate dryers along north wall of Laundry Room. o Extend dryer exhaust ductwork to new dryers. o Reconnect power to new washers and dryers and provide new non-fused disconnects. o Extend CW, HW and drain piping to new washers o Extend natural gas piping to new dryers. o Repair dryer outside air supply grill. • Remove existing dishwasher and associated abandoned mechanical and electrical. • Relocate smoke detectors, exit signs, egress lighting, etc. to accommodate relocated doorway to laundry. • Replace existing fluorescent lighting fixtures with new LED vapor-tight ceiling mounted fixtures. • Install new towel folder o Extend new power circuit. o Extend existing compressed air to folder. • Inspect existing commercial laundry exhaust duct system. Repair ductwork leaks, if any. Clean duct if necessary. • Relocate existing doorway from Laundry Room to Service Corridor. 6" door to be replaced with 5' door system. GENERAL NOTES 1. Obtain and pay for all necessary permits, inspections and fees or charges necessary for execution and completion of the work. 2. Conform to the prevailing edition of the International Codes, National Electric Code and to the Town of Vail requirements. 3. The building will be occupied by the owner during construction. Continued operation of the facility shall not be hindered by this work unless coordinated with the owner in advance. 4. Field verify existing equipment or ductwork remaining to be connected to new or existing systems. Provide ductwork, controls, diffusers, etc. as required to restore continuity of systems or to make work meet existing conditions whether indicated or not. 5. Provide demolition as required and dispose of all removed ductwork, equipment, conduit, etc. 6. Offset ductwork as necessary to accommodate structure, beams, columns and existing equipment. 7. All existing support rods and strap now supporting ducts, pipes, conduit, etc. that are removed to allow room for installation of new equipment shall be relocated and reinstalled, or replaced if damaged. 8. Extend and/or modify existing MEP utility services to new laundry equipment in ccordance with equipment manufacturers' requirements. SHEET MEP-1