Loading...
HomeMy WebLinkAboutB18-0441_APPROVED DOCUMENTS_1539024221.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspections: inspections@vailgov.com Construction B18-0441 Issued: 10/08/2018 TOWN OF VAIL Property Information Address: 600 VAIL VALLEY DR A14 (210108111014 A14) ( 210108111014 ) Unit #: A14 Parcel Number: 210108111014 Legal Description: DESC: PK SP AP12 & AP13 Subdivision: NORTHWOODS CONDOMINIUMS Unit: A-14 Contacts Contact Type: Applicant Full Name: Brian Williams Address: PO Box 1154 307 Amherst Rd Gypsum, CO 81637 Phone: 9703900508 Contact Type: Property Owner Full Name: KISHA LLC Address: Phone: None Contractor Contractor Type: Plumbing Company: R & R Heating, Inc State License #: PC-2032 Phone: 9703900508 Project Information Project Name: Kisha LLC Boiler 2018 Project Description: Emergency Boiler change out, Leaking heat exchanger. Same style & brand of boiler to be installed new boiler efficiency is 85%. Will be installing on 10/3/18. Fees Paid Account #: 001-0000.31111.00 - Building Permit Fee Fee Amount:$125.25 Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$120.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$30.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Total Paid:$280.25 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. Standard Equipment • PI Controller • Outdoor reset with ratios of 0.4 to 3.6 • Warm Weather Shutdown (WWSD) • Domestic Hot Water Operation (DHW) • Indicator lights for power, heat call, DHW call and WWSD • Automatic boiler differential • Pump pre-purge, post-purge and excercise • Codes for sensor errors • Venting: built-in draft diverter • Design certified/tested by CSA International • Natural or propane gas • Maximum working pressure: water 30 P.S.I., ASME rated • Hydrostatic test pressure at factory: 60 P.S.I. Hydronic Boilers JVS Residential Gas-Fired Boiler Indoor Sizes 50-225 MBTU/h Submittal Data Minimum Clearances, inches cm Size Left + Right Sides, Rear Front Flue Top 50 6 15 4 10 6 15 23 58 75 6 15 4 10 6 15 23 58 100 6 15 4 10 6 15 23 58 125 6 15 4 10 6 15 23 58 160 6 15 4 10 6 15 36 91 225 6 15 4 10 6 15 36 91 • 30 psi ASME pressure relief valve • Maximum gas supply pressure: Natural 10.5" W.C.; Propane 13" W.C. • Pressure relief valve: capacity in ex- cess of boiler input rating • Material specifications per Section IV, ASME Code • Headers: cast iron per ASME require- ments • Tubes: copper with integral formed external fins • Main burners: aluminized steel • Air supply: natural aspiration • Altitudes: 0–10,000 ft. • Spark to pilot ignition • Electrical: 115V-60Hz-1PH less than 12 Amps 24V transformer mounted and wired Minimum Clearances from Adjacent Construction MINI-THERM ® JVS • Pump relay: standard • Vent damper and wire harness • Blocked vent safety switch (B.V.S.S.) • Flame rollout safety switch • Up to 85% AFUE • 20-Year Limited Warranty Dimensional Data Dimensions shown in inches cm. Dimensions Approx inches cm Weight Size A B C D E V lbs. kg 50 13-3/8 34 27-3/4 71 23-5/8 60 21-3/4 55 26-1/2 67 4 10 120 54 75 13-3/8 34 27-3/4 71 24-1/8 61 21-3/4 55 27-1/2 70 5 13 126 57 100 16-7/8 43 28-3/4 73 24-1/8 61 22-3/4 58 27-1/2 70 5 13 134 61 125 16-7/8 43 28-3/4 73 23-5/8 60 22-3/4 58 27-1/2 70 6 15 138 63 160 20-3/8 52 28-3/4 73 23-5/8 60 22-3/4 58 27-1/2 70 6 15 164 74 225 25-5/8 65 31-1/2 80 23-1/4 59 24-3/4 63 27-1/2 70 7 18 181 82 Heating Capacity AFUE % Water Gas Input Nat Gas Propane Gas Nat Gas Prop Gas Conn. Conn. Size MBTU/h kW MBTU/h kW MBTU/h kW % % in. 50 50 14.7 43 12.6 43 12.6 85.0 85.4 1-1/4 1/2 75 75 22.0 64 18.8 64 18.8 85.0 85.2 1-1/4 1/2 100 100 29.3 85 24.9 85 24.9 85.0 85.0 1-1/4 1/2 125 125 36.6 106 31.1 106 31.1 85.0 85.0 1-1/4 1/2 160 160 46.9 136 39.8 136 39.8 85.0 85.0 1-1/4 1/2 225 225 65.9 191 56.0 190 55.7 85.0 85.0 1-1/4 3/4* Vent Damper optional in Canada Top View Side View Front View B D V E 9-1/4 24 7 18 17-3/4 Vent Damper Harness 1-1/4 NPT Draft Diverter A/2 C A In Return T&P Gauge Out Supply PRV 45 Customer Service and Product Support: 800.900.9276 • Fax 800.559.1583 Headquarters: 20 Industrial Way, Rochester, NH 03867 • 603.335.6300 • Fax 603.335.3355 1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 • 905.238.0100 • Fax 905.366.0130 www.Laars.com Litho in U.S.A. © Laars Heating Systems 1508 Document 1040Z Laars Heating Systems Company reserves the right to change specifications, components, features, or to discontinue products without notice. *1/2" for propane