Loading...
HomeMy WebLinkAboutB18-0458_Approved Documents_1539362956.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspections: inspections@vailgov.com Expedited B18-0458 Issued: 10/12/2018 TOWN OF VAIL Property Information Address: 1030 LIONS RIDGE LP 102 (210301416002 102) ( 210301416002 ) Unit #: 102 Parcel Number: 210301416002 Legal Description: Subdivision: SNOW FOX CONDOS Unit: 102 BK-0443 PG-0161 TD 11-22-81 BK-0444 PG-0064 QCD 06-24-86 BK-0486 PG-0162 QCD 04-15-88 BK-0499 PG-0776 02-02-89 BK-0511 PG-0952 BSD 08-17- 89 R682379 WD 10-10-98 Contacts Contact Type: Applicant Full Name: Delta Mechanical Address: 6056 E Baseline Rd #155 155 Mesa, AZ 85206 Phone: 8666925273 Contact Type: Property Owner Full Name: PAULSEN, ROBERT & KRISTIN Address: Phone: None Contractor Contractor Type: Plumbing Company: Colorado Delta Mechanical Inc State License #: 8099 Phone: 866-692-5273 Project Information Project Name: Paulsen Water Heater 2018 Project Description: Electric water heater replacement, exp tank 303.638.1428 Fees Paid Account #: 001-0000.31111.00 - Mechanical Permit Fee Fee Amount:$20.00 Account #: 001-0000.31123.00 - Mechanical Plan Review Fee Fee Amount:$5.00 Account #: 001-0000.31128.00 - Will Call Fee (Mechanical Scope)Fee Amount:$5.00 Total Paid:$30.00 Conditions CONDITIONS UNDER WHICH PERMITS BECOME VOID: If construction is not begun within 6 months from the date permit was issued. If more than 5 months elapses between inspections. If incorrect information is given on the application at the time the permit was issued. Christopher Jarecki - Town of Vail Building Official NOTICE: By issuance of this Permit the applicant agrees to comply with all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. PERMIT FEE RECEIPT Case # B18-0458 Date Printed: 10/12/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: B18-0458 Status: Approved Permit Number: Date Started: 10/08/2018 Permit Type: Expedited Subcases Water Heater Lot Number: B1 & B2 Property: 1030 LIONS RIDGE LP 102 (210301416002 102) (210301416002) Contacts Contact Type: Applicant Company Name: Colorado Delta Mechanical Full Name: Delta Mechanical Address: 6056 E Baseline Rd #155 155 Mesa, AZ 85206 Email: copermits@deltamechanical.com Contact Type: Property Owner Full Name: PAULSEN, ROBERT & KRISTIN Address: Permit Fees Fee Information Account Amount Permit Fee 001-0000.31111.00 $20.00 Plan Review 001-0000.31123.00 $5.00 Will Call Fee 001-0000.31128.00 $5.00 Payment Information Date Paid Payment Type Amount Will Call Fee 10/12/2018 Credit Card $5.00 Paid By: - Notes: visa-delta mechanical Permit Fee 10/12/2018 Credit Card $20.00 Paid By: - Notes: visa-delta mechanical Plan Review 10/12/2018 Credit Card $5.00 Paid By: - Notes: visa-delta mechanical FEE TOTAL $30.00 AMOUNT PAID $30.00 BALANCE DUE $0.00 10/12/2018 - 10:42:43 AM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657 1 / 1 Water Heaters Electric Residential The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater; and two, for the owner–operator, to explain the features, operation, safety precautions, maintenance and troubleshooting of the water heater. This manual also includes a parts list. It is imperative that all persons who are expected to install, operate or adjust this water heater read the instructions carefully so they may understand how to perform these operations. If you do not understand these instructions or any terms within it, seek professional advice. Any questions regarding the operation, maintenance, service or warranty of this water heater should be directed to the seller from whom it was purchased. If additional information is required, refer to the section on “If you need service.” Do not destroy this manual. Please read carefully and keep in a safe place for future reference. ! Recognize this symbol as an indication of Important Safety Information! ! California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. with Electronic Control ® LISTED 786H AP16697-1 (10/13)Printed in USA Use & Care Manual With Installation Instructions for the Installer 2 Care and Cleaning Draining ................ 20 Maintenance ............. 20 Extended Shut-Down ..... 21 Safety Information Safety Precautions ....... 3, 4 Installation Instructions Location ................. 5 Water Connections ........ 6 Electrical Connections. . . . . . 8 Operating Instructions Safety Controls .......... 12 Water Temperature ........13 Electronic Control Operation . . . . . . . . . . . . . . .18 Troubleshooting Tips Before You Call For Service .............. 22 Customer Service Parts List ................ 23 Wiring Diagram ......... 25 If You Need Service ................. 28 FOR YOUR RECORDS Write the model and serial numbers here: # # You can find them on a label on the appliance. Staple sales slip or cancelled check here. Proof of the original purchase date is needed to obtain service under the warranty. Inside you will find many helpful hints on how to use and maintain your water heater properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your water heater. You’ll find many answers to common problems in the Before You Call For Service section. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all. READ THIS MANUAL Your safety and the safety of others are very important. There are many important safety messages in this manual and on your appliance. Always read and obey all safety messages. ! This is the safety alert symbol. Recognize this symbol as an indication of Important Safety Information! This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER”, “WARNING”, “CAUTION” or “NOTICE”. These words mean: ! DANGER An imminently hazardous situation that will result in death or serious injury. ! WARNING A potentially hazardous situation that could result in death or serious injury and/or damage to property. ! CAUTION A potentially hazardous situation that may result in minor or moderate injury. Notice: Attention is called to observe a specified procedure or maintain a specific condition. READ THE SAFETY INFORMATION 3 Time/Temperature Relationship in Scalds Temperature Time To Produce a Serious Burn 120°F More than 5 minutes 125°F 1½ to 2 minutes 130°F About 30 seconds 135°F About 10 seconds 140°F Less than 5 seconds 145°F Less than 3 seconds 150°F About 1½ seconds 155°F About 1 second Table courtesy of Shriners Burn Institute The chart shown above may be used as a guide in determining the proper water temperature for your home. ! DANGER: Households with small children, disabled, or elderly persons may require a 120°F or lower thermostat setting to prevent contact with “HOT” water. The temperature of the water in the heater is regulated by the electronic control and surface mounted temperature sensors. To comply with safety regulations the electronic control was programmed with a 120°F set point at the factory. DO NOT attempt to set the temperature by removing the electronic control or lower access panel. See the electronic control operation section of this manual. ! DANGER: Hotter water increases the potential for Hot Water SCALDS. DANGER ! HOT Water temperature over 125 °F can cause severe burns instantly or death from scalds. Children, disabled and elderly are at highest risk of being scalded. See instruction manual before setting temperature at water heater. Feel water before bathing or showering. Temperature limiting valves are available, see manual. BURN IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. DANGER! WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting of water heater’s thermostat. Water temperatures above 125°F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below. This label is also located on the water heater near the thermostat access panel. NOTICE: Mixing valves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines. Contact a licensed plumber or the local plumbing authority for further information. 4 IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. It may save you time and cost. Pay particular attention to the Safety Instructions. Failure to follow these warnings could result in serious bodily injury or death. Should you have problems understanding the instructions in this manual, or have any questions, STOP, and get help from a qualified service technician, or the local electric utility. FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that residential water heaters must be braced, anchored or strapped to resist falling or horizontal displacement due to earthquake motions. For residential water heaters up to 52 gallon capacity, a brochure with generic earthquake bracing instructions can be obtained from: Office of the State Architect, 400 P Street, Sacramento, CA 95814 or you may call 916-324-5315 or ask a water heater dealer. However, applicable local codes shall govern installation. For residential water heaters of a capacity greater than 52 gallons, consult the local building jurisdiction for acceptable bracing procedures. READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS Have the installer show you the location of the circuit breaker and how to shut it off if necessary. Turn off the circuit breaker if the water heater has been subjected to overheating, fire, flood, physical damage or if the ECO fails to shut off. ● Read this manual entirely before installing or operating the water heater. ● Use this appliance only for its intended purpose as described in this Use and Care Manual. ● Be sure your appliance is properly installed in accordance with local codes and the provided installation instructions. ● DO NOT attempt to repair or replace any part of your water heater unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician. SAFETY PRECAUTIONS 5 Installing the water heater. The location chosen for the water heater must take into consideration the following: Local Installation Regulations This water heater must be installed in accordance with these instructions, local codes, utility codes, utility company requirements or, in the absence of local codes, the latest edition of the National Electrical Code. It is available from some local libraries or can be purchased from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269 as booklet ANSI/NFPA 70. Location Locate the water heater in a clean dry area as near as practical to the area of greatest heated water demand. Long un-insulated hot water lines can waste energy and water. Place the water heater in such a manner that the upper electronic control and the lower access panels can be removed to permit inspection and servicing such as removal of elements or checking controls. The water heater and water lines should be protected from freezing temperatures. Do not install the water heater in outdoor, unprotected areas. Make certain the floor underneath the water heater is strong enough to sufficiently support the weight of the water heater once it is filled with water. CAUTION: The water heater should not be located in an area where leakage of the tank or connections will result in damage to the area adjacent to it or to lower floors of the structure. Where such areas cannot be avoided, it is recommended that a suitable catch pan, adequately drained, be installed under the water heater. This water heater is supplied with a water detection system. It is recommended that the water heater be placed in a suitable catch pan and the water sensor rope be placed inside the catch pan. See water sensor section for further information. A— Diameter of water heater plus 2″ min. B— Maximum 2″ NOTICE: Auxiliary catch pan MUST conform to local codes. Catch Pan Kits are available from the store where the waterheater was purchased, or any water heater distributor. B A To open drain, line should be at least 3/4″ ID and pitched for proper drainage. Inspect Shipment Inspect the water heater for possible damage. Check the markings on the rating plate of the water heater to be certain the power supply corresponds to the water heater requirements. ! NOTICE: Do not install the water heater in attics where the temperature may exceed 150°F. 6 Installing the water heater. Typical Installation Thermal Expansion Determine if a check valve exists in the inlet water line. Check with your local water utility. It may have been installed in the cold water line as a separate back flow preventer, or it may be part of a pressure reducing valve, water meter or water softener. A check valve located in the cold water inlet line can cause what is referred to as a “closed water system”. A cold water inlet line with no check valve or back flow prevention device is referred to as an “open” water system. As water is heated, it expands in volume and creates an increase in the pressure within the water system. This action is referred to as “thermal expansion”. In an “open” water system, expanding water which exceeds the capacity of the water heater flows back into the city main where the pressure is easily dissipated. A “closed water system”, however, prevents the expanding water from flowing back into the main supply line, and the result of “thermal expansion” can create a rapid and dangerous pressure increase in the water heater and system piping. This rapid pressure increase can quickly reach the safety setting of the relief valve, causing it to operate during each heating cycle. Thermal expansion, and the resulting rapid and repeated expansion and contraction of components in the water heater and piping system can cause premature failure of the relief valve, and possibly the heater itself. Replacing the relief valve will not correct the problem! The suggested method of controlling thermal expansion is to install an expansion tank in the cold water line between the water heater and the check valve (refer to the illustration below). The expansion tank is designed with an air cushion built in that compresses as the system pressure increases, thereby relieving the over pressure condition and eliminating the repeated operation of the relief valve. Other methods of controlling thermal expansion are also available. Contact your installing contractor, water supplier or plumbing inspector for additional information regarding this subject. NOTICE: Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater. Any heat applied to the water supply fittings will permanently damage the dip tube and/or heat traps. Water Supply Connections Refer to the illustration below for suggested typical installation. The installation of unions or flexible copper connectors is recommended on the hot and cold water connections so that the water heater may be easily disconnected for servicing if necessary. The HOT and COLD water connections are clearly marked and are 3/4″ NPT on all models. Install a shut-off valve in the cold water line near the water heater. Vacuum Relief Valve (Not Supplied) If required, install per local codes and valve manufacturer’s instructions. To electric distribution panel Heat trap 6" minimum Auxiliary catch pan 2" maximum Drain Valve 6" air gap Relief valve discharge line to suitable open drain Thermal expansion tank (if required) Heat trap 6" minimum To cold water supply Hot water outlet to fixture Temperature & Pressure Relief Valve Electronic Control Lower Access Panel Electrical junction box (use only copper conductors) Shut-off valve Anode Union Union EcoNetTM Port 7 ! WARNING: The pressure rating of the relief valve must not exceed 150 PSI, the maximum working pressure of the water heater as marked on the rating plate. A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must be installed in the opening provided and marked for the purpose on the water heater. No valve of any type should be installed between the relief valve and the tank. Local codes shall govern the installation of relief valves. Relief Valve The BTUH rating of the relief valve must not be less than the input rating of the water heater as indicated on the rating label located on the front of the heater (1 watt=3.412 BTUH). Connect the outlet of the relief valve to a suitable open drain so that the discharge water cannot contact live electrical parts or persons and to eliminate potential water damage. Piping used should be of a type approved for hot water distribution. The discharge line must be no smaller than the outlet of the valve and must pitch downward from the valve to allow complete drainage (by gravity) of the relief valve and discharge line. The end of the discharge line should not be threaded or concealed and should be protected from freezing. No valve of any type, restriction or reducer coupling should be installed in the discharge line. To Fill the Water Heater Make certain the drain valve is completely closed. Open the shut-off valve in the cold water supply line. Open each hot water faucet slowly to allow the air to vent from the water heater and piping. A steady flow of water from the hot water faucet(s) indicates a full water heater. ! WARNING: The tank must be full of water before heater is turned on. The water heater warranty does not cover damage or failure resulting from operation with an empty or partially empty tank. Condensation Condensation can form on the tank when it is first filled with water. Condensation might also occur with a heavy water draw and very cold inlet water temperature. This condition is not unusual, and will disappear after the water becomes heated. If, however, the condensation continues, examine the piping and fittings for possible leaks. EcoNetTM Communication Port EcoNetTM Communication port is for future integration with home automation, energy management, and demand response systems. 8 Installing the water heater. NOTICE: This guide recommends minimum branch circuit sizing and wire size based on National Electric Code. Refer to wiring diagrams in this manual for field wiring connections. Branch Circuit Sizing and Wire Size Guide CAUTION: The presence of water in the piping and water heater does not provide sufficient conduction for a ground. Non-metallic piping, dielectric unions, flexible connectors etc. can cause the water heater to be electrically isolated. Electrical Connections A separate branch circuit with copper conductors, overcurrent protective device and suitable disconnecting means must be provided by a qualified electrician. All wiring must conform to local codes or latest edition of National Electrical Code ANSI/NFPA 70. The water heater is completely wired to the junction box inside jacket at the top front of the water heater. An opening for 1/2″ or 3/4″ electrical fitting is provided for field wiring connections. The voltage requirements and wattage load for the water heater are specified on the rating plate on the front of the water heater. The branch circuit wiring should include either: Metallic conduit or metallic sheathed cable approved for use as a grounding conductor and installed with fittings approved for the purpose. Non-metallic sheathed cable, metallic conduit or metallic sheathed cable not approved for use as a ground conductor shall include a separate conductor for grounding. It should be attached to the ground terminals of the water heater and the electrical distribution box. Water heater junction box. WARNINGWARNI NG Junction box cover Wire connections Ground screw Conduit connector Single Phase Wiring Total Water Heater Wattage Recommended Over Current Protection (fuse or circuit breaker amperage rating) Copper Wire Size AWG Based on N.E.C Table 310-16 (75oC) 208V 240V 208V 240V 3,000 20 20 12 12 4,000 25 25 10 10 4,500 30 25 10 10 5,000 30 30 10 10 5,500 35 30 8 10 ! 9 For increased energy efficiency, some water heaters have been supplied with two 24” sections of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements. Typical vertical piping arrangement Typical horizontal piping arrangement Hot and Cold Pipe Insulation Installation Insulation blankets, available to the general public, for external use on electric water heaters are not necessary. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. This water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary. The manufacturer’s warranty does not cover any damage or defect caused by installation, attachment or use of any type of energy saving or other unapproved devices (other than those authorized by the manufacturer) into, onto or in conjunction with the water heater. The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property. The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices. !CAUTION: If local codes require the application of an external insulation blanket to this water heater, pay careful attention to the following so as not to restrict the proper function and operation of the water heater:  Do not cover the operating or warning labels attached to the water heater or attempt to relocate them on the exterior of insulation blanket.  Do not apply insulation to the top of the water heater. This could interfere with the safe operation of the electrical junction box.  Do not cover the jacket access panel(s) to the thermostat(s) and heating element(s), or pressure and temperature relief valve.  Inspect the insulation blanket frequently. !WARNING: If local codes require external application of insulation blanket kits the manufacturer’s instructions included with the kit must be carefully followed. Insulation Blankets 10 Installing the water heater. For increased energy efficiency, some water heaters have been supplied with a 2-3/8” section of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements. Slip the insulation cover over the T&P Valve through the center hole and align the hole in the side with the opening of the T&P Valve. Typical top connection arrangement Typical side connection arrangement Relief Valve Insulation Installation ! CAUTION: Ensure the T&P Valve opening is not obstructed by the insulation. Heat Trap For increased energy efficiency, some water heaters have been supplied with factory installed internal or external heat traps in the hot outlet and cold water inlet openings. NOTICE: Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater. Any heat applied to the water supply fittings will permanently damage the dip tube and/ or heat traps. Water Sensor In order to detect the presence of unwanted water, this water heater is supplied with a built-in water sensing circuit. The water sensor rope is shipped in the warranty bag for field installation. Remove water sensor rope from the bag and attach to the connector located near the lower access panel. Place the rope in the recommended catch pan and secure to the pan bottom with provided self adhesive clips. When water is detected, the electronic control will turn off the heating elements, flash the display backlight and turn on an audible alarm. Water Sensor Rope Attachment Point Clips Catch Pan 11 Installation Checklist A. Water Heater Location B. Water Supply C. Relief Valve D. Wiring ❑ Close to area of heated water demand. ❑ Indoors and protected from freezing temperatures. ❑ Area free of flammable vapors. ❑ Provisions made to protect area from water damage. ❑ Sufficient room to service heater. ❑ Water heater completely filled with water. ❑ Air purged from water heater and piping. ❑ Water connections tight and free of leaks. ❑ Temperature and Pressure Relief Valve properly installed and discharge line run to open drain. ❑ Discharge line protected from freezing. ❑ Power Supply voltage agrees with water heater rating plate. ❑ Branch circuit wire and fusing or circuit breaker of proper size. ❑ Electrical connections tight and unit properly grounded. E. Water Sensor ❑ Water heater in catch pan ❑ Water sensor rope connected to heater ❑ Water sensor rope inside catch pan and secured with clip 12 Safety Precautions Do turn off power to water heater if it has been subjected to over heating, fire, flood, physical damage. Do Not turn on water heater unless it is filled with water. Do Not turn on water heater if cold water supply shut-off valve is closed. If there is any difficulty in understanding or following the Operating Instructions or the Care and Cleaning section, it is recommended that a qualified person or serviceman perform the work. Operating the water heater. CAUTION: Hydrogen gas can be produced in a hot water system served by this water heater that has not been used for a long period of time (generally two weeks or more). HYDROGEN GAS IS EXTREMELY FLAMMABLE!! To dissipate such gas and to reduce risk of injury, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. If hydrogen is present, there will be an unusual sound such as air escaping through the pipe as the water begins to flow. Do not smoke or use an open flame near the faucet at the time it is open. Safety Controls The water heater is equipped with a temperature sensor and temperature limiting control (ECO) that is located above the upper heating element in contact with the tank surface. If for any reason the water temperature becomes excessively high, the temperature limiting control (ECO) breaks the power circuit to the heating element. Once the control opens, it must be reset manually. CAUTION: The cause of the high temperature condition must be investigated by qualified service technician and corrective action must be taken before placing the water heater in service again. To reset the temperature limiting control: Turn off the power to the water heater. Remove the electronic control and insulation. The thermostat protective cover should not be removed. Press the red RESET button. Replace the insulation and electronic control before turning on the power to the water heater. Reset button Thermostat protective cover WARNING: If the water heater has been subjected to flood, fire, or physical damage, turn off power and water to the water heater. DO NOT operate the water heater again until it has been thoroughly checked by qualified service personnel. 13 Water Temperature Time/Temperature Relationship in Scalds Temperature Time To Produce a Serious Burn 120°F More than 5 minutes 125°F 11/2 to 2 minutes 130°F About 30 seconds 135°F About 10 seconds 140°F Less than 5 seconds 145°F Less than 3 seconds 150°F About 11/2 seconds 155°F About 1 second Table courtesy of Shriners Burn Institute ! DANGER: There is a hot water scald potential if the thermostat is set too high. Households with small children, disabled, or elderly persons may require a 120°F or lower thermostat setting to prevent contact with HOT water. Water Temperature Set Point Safety and energy conservation are factors to be considered when selecting the water temperature setting of the water heater’s thermostat(s). The lower the temperature setting, the greater the savings in energy and operating costs. To comply with safety regulations the electronic control is factory programmed at 120°F or less where local codes require. This is the recommended starting point. Water temperatures above 125°F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined in this manual and on the label on the water heater. This label is located on the water heater above the lower access panel. Mixing valves for reducing point of use water temperature by mixing hot and cold water in branch water lines are available. Contact a licensed plumber or the local plumbing authority for further information. The electronic control allows the water temperature to be set from 110°F to 150°F. The chart below may be used as a guide in determining the proper water temperature for your home. 14 POWERING ON WATER HEATER SETTING WATER TEMPERATURE LOCKING THE SCREEN or Lock Icon *Note: If screen is dimmed press any buton and release to brighten the display before performing desired acton. Press and hold the On/Off buton for 3 seconds to turn the water heater On Reduce Water Temperature: Press DOWN arrow untl desired temperature is shown on display. Increase Water Temperature: Press UP arrow untl desired temperature is shown on display. Press and hold both arrow butons for 3 seconds to LOCK the control. Locking will reduce chance of unintentonal changes in water temperature. Programming the Electronic Control 15 VACATION SETTING ON VACATION SETTING OFF UNLOCKING THE SCREEN Lock Icon HEATING STATUS SCROLLING DOT When a dot scrolls between the numbers, this means that the heatng element is on. Press and hold both arrow butons for 3 seconds to UNLOCK the control. *Note: If screen is dimmed press any buton and release to brighten the display before performing desired acton. Press and hold the VACATION buton for 3 seconds to place the water heater in vacaton mode. This mode will reduce the water temperature to save energy during tmes when hot water is not needed. Press and hold the VACATION buton for 3 seconds to remove the water heater from vacaton mode. This will return the temperature setng to the previous set point before initatng vacaton mode. 16 CONFIGURATION MENU – MODE – CONFIGURE – STATUS – HISTORY PRESS TO SELECT ENERGY SAVER – HIGH TEMP DISPLAY – BEEP – INSTANCE MODE CONFIGURE PRESS TO SELECT Press and release the MENU/SELECT buton to enable the configuraton menu. Use UP/DOWN arrow butons to scroll through the available configuraton setngs. Press MENU/SELECT buton to choose the desired menu item. See below for further optons. The MODE menu is used to change the water heater from PERFORMANCE mode to ENERGY SAVER mode. Use DOWN arrow to change the mode. The CONFIGURE menu is used to change additonal setngs for the water heater performance and display optons. Press the DOWN arrow buton to scroll through the available setngs. Press MENU/SELECT buton to choose the desired configuraton opton. See following sheet for explanaton for each configuraton setng. *Note: If screen is dimmed press any buton and release to brighten the display before performing desired acton. VERSION INFORMATION– – – Programming the Electronic Control 17 CHANGE CHANGE SCROLL DISPLAY BEEP INSTANCE – NO -YES PRESS TO SELECT HIGH TEMPERATURE High temperature mode will allow the water temperature to be set above 140 degrees F. Press the DOWN arrow to change setng then press SELECT. *Note: If screen is dimmed press any buton and release to brighten the display before performing desired acton. Display mode is used to change the temperature displayed from Fahrenheit to Celsius. Press either UP or DOWN arrow to change. Beep mode is use to turn all the audible alarms on and off. Press either UP or DOWN arrow to change. In this mode, error alarms and water sensor detecton alarms will not occur. Instance number is used to identfy the water heater if additonal water heaters or devices are connected to a joint home control system. The number may be changed from 1 to 16 to identfy this water heater. 18 Programming the Electronic Control –HEAT –UPPER TEMP –LOWER TEMP SCROLL PRESS TO SELECT STATUS HISTORY Use DOWN arrow to scroll through the menu. Press MENU/SELECT buton to actvate menu item. HEAT will display if an element is on or off. Choosing UPPER or LOWER TEMP will display the current temperature reading for that sensor. History menu lists the 10 most recent error codes. Use the DOWN arrow to scroll the codes. ERROR DISPLAY ERROR SYMBOL History menu lists the 10 most recent error codes. Press the BACK/STATUS buton to show the most recent error code. Use the DOWN arrow to scroll the codes. See following sheet for all error codes, scrolling messages and recommended acton. *Note: If screen is dimmed press any buton and release to brighten the display before performing desired acton. 19 CODE SCROLLING MESSAGE DESCRIPTION/ACTION A100 Lower temperature thermistor failure Electronic control has detected lower temperature sensor is bad. The problem could be the sensor, wiring, or the control board. Please call for service. A101 Upper temperature thermistor failure Electronic control has detected upper temperature sensor is bad. The problem could be the sensor, wiring, or the control board. Please call for service. A102 Water sensor alarm Electronic control has detected water in the drain pan. Check the pan for water. If there is no water present, disconnect the sensor, dry and reinstall it to reset the error. A103 Fill tank with water Electronic control has detected no water in the tank. Please fill the tank with water and recycle power. A104 Emergency cut off alarm Electronic control has detected high temperature electrical cut-out device (ECO) has been activated. Reset ECO or call for service A105 Lower element error Electronic control has detected an error with the lower element or associated wiring and connections. Please call for service. A106 Upper element error Electronic control has detected an error with the upper element or associated wiring and connections. Please call for service. A107 Element wire routing error Call for service A108 Lower element relay stuck on error If this error is displayed, the control board will have to be replaced. Please call customer service. A109 Upper element relay stuck on error If this error is displayed, the control board will have to be replaced. Please call customer service. A110 Lower temperature conversion error If this error is displayed, the control board will have to be replaced. Please call customer service. A111 Upper temperature conversion error If this error is displayed, the control board will have to be replaced. Please call customer service. A500 Control Failure If this error is displayed, the control board will have to be replaced. Please call customer service. Error Codes for Electronic Control ERROR CODES CAUTION: For your safety DO NOT attempt repair of electrical wiring, temperature sensor, electronic control, heating elements or other safety devices. Refer repairs to qualified service personnel. ! 20 Care and cleaning of the water heater. Draining the Water Heater CAUTION: Shut off power to the water heater before draining water. DANGER: Before manually operating the relief valve, make certain no one will be exposed to the hot water released by the valve. The water drained from the tank may be hot enough to present a scald hazard and should be directed to a suitable drain to prevent injury or damage. In order to drain the water heater, turn off the cold water supply. Open a hot water faucet or lift the handle on the relief valve to admit air to the tank. Attach a garden hose to the drain valve on the water heater and direct the stream of water to a drain. Open the valve. Routine Preventative Maintenance Properly maintained, your water heater will provide years of dependable trouble- free service. It is suggested that a routine preventive maintenance program be established and followed by the user. It is further recommended that a periodic inspection of the operating controls, heating element and wiring should be made by service personnel qualified in electric appliance repair. Most electrical appliances, even when new, make some sound when in operation. If the hissing or singing sound level increases excessively, the electric heating element may require cleaning. Contact a qualified installer or plumbing contract to inspect. At least once a year, lift and release the lever handle on the temperature pressure relief valve, located near the top of the water heater, to make certain the valve operates freely. Allow several gallons to flush through the discharge line to an open drain. A water heater’s tank can act as a setting basin for solids suspended in the water.It is therefore not uncommon for hard water deposits to accumulate in the bottom of the tank. It is suggested that a few quarts of water be drained from the water heater’s tank every month to clean the tank of these deposits. Rapid closing of faucets or solenoid valves in automatic water using appliances can cause a banging noise heard in a water pipe. Strategically located risers in the water pipe system or water hammer arresting devices can be used to minimize the problem. The anode rod should be removed from the water heater’s tank annually for inspection and replaced when more than 6″ of core wire is exposed at either end of the rod. Make sure the cold water supply is turned off before removing anode rod. DANGER: Before manually operating the relief valve, make certain no one will be exposed to the danger of coming in contact with the hot water released by the valve. The water may be hot enough to create a scald hazard. The water should be released into a suitable drain to prevent injury or property damage. NOTICE: If the temperature and pressure relief valve on the hot water heater discharges periodically, this may be due to thermal expansion in a closed water system. Contact the water supplier or your plumbing contractor on how to correct this. Do not plug the relief valve outlet. 21 Care and cleaning of the water heater. Extended Shut-Down If the water heater is to remain idle for an extended period of time, the power and water to the appliance should be turned off to conserve energy and prevent a build-up of dangerous hydrogen gas. The water heater and piping should be drained if they might be subjected to freezing temperatures. After a long shut-down period, the water heater’s operation and controls should be checked by qualified service personnel. Make certain the water heater is completely filled again before placing it in operation. NOTICE: Refer to the Hydrogen Gas Caution in the Operating Instructions. Anode Rod This water heater is equipped with an anode rod designed to prolong the life of the glass lined tank. The anode rod is slowly consumed, thereby eliminating or minimizing corrosion of the glass lined tank. Water sometimes contains a high sulfate and/or mineral content and together with cathodic protection process can produce a hydrogen sulfide, or rotten egg odor in the heated water. Chlorination of the water supply should minimize the problem. NOTICE: Do not remove the anode rod from the water heater’s tank, except for inspection and/or replacement, as operation with the anode rod removed will greatly shorten the life of the glass lined tank and will exclude warranty coverage. 22 Before You Call For Service… Troubleshooting Tips Save time and money! Review the chart on this page first and you may not need to call for service. CAUTION: For your safety DO NOT attempt repair of electrical wiring, temperature sensor, electronic control, heating elements or other safety devices. Refer repairs to qualified service personnel. ! Problem Possible Causes What To Do Rumbling noise Water conditions in your home caused a build up of scale or mineral deposits on the heating elements. ● Remove and clean the heating elements. Relief valve producing popping noise or draining Pressure build up caused by thermal expansion in a closed system. ● This is an unacceptable condition and must be corrected. Contact the water supplier or plumbing contractor on how to correct this. Do not plug the relief valve outlet. Rattling noise during periods of water usage Internal heat trap fittings in operation. ● This is normal for heat trap fittings when in operation and does not indicate a need for service. Not enough or no hot water Water usage may have exceeded the capacity of the water heater. ● Wait for the water heater to recover after an abnormal demand. A fuse is blown or a circuit breaker tripped. ● Replace fuse or reset circuit breaker. Electric supply may be off. ● Make sure electric supply to water heater and disconnect switch, if used, are in the ON position. The thermostat may be set set too low. ● See the Temperature regulation of the water heater sec- tion of this manual. Leaking or open hot water faucets. ● Make sure all faucets are closed. Electric service to your home may be interrupted. ● Contact the local electric utility. Improper wiring. ● See the Installing the water heater section of this manual. Manual reset limit (ECO). ● See the Temperature regulation of the water heater sec- tion of this manual. Cold water inlet temperature may be colder during the winter months. ● This is normal. The colder inlet water takes longer to heat. Water is too hot The thermostat is set too high. ● See the Temperature regulation of the water heater sec- tion of this manual. Cannot set above 140°F Electronic control high temp configuration set to NO. ● See configuration menu section on programming the electronic control. 23 Replacement Parts. For 20–120 gallon models with single and double elements. Instructions For Placing a Parts Order Address parts orders to the distributor or store where the heater was purchased. All parts orders should include: The model and serial number of the water heater from the rating plate. Specify voltage and wattage as marked on the rating plate. Part description (as noted below) and number of parts desired. ! CAUTION: For your safety DO NOT attempt repair of electrical wiring, thermostat(s), heating elements or other operating controls. Refer repairs to qualified service personnel. Some models may have been supplied with External heat traps in lieu of Internal heat traps Electronic Control Cavity insulation Upper thermostat protective cover ECO with upper sensor Jacket access panel Thermostat bracket Drain valve Lower sensor Heating Element Heating element gasket Plate cover Junction box cover Anode rod Dip tube gasket Dip tube / internal heat trap Temperature & Pressure Relief Valve Internal heat trap Internal heat trap gasket Upper thermostat bracket Heating element Heating element gasket Water Sensor Connector 24 Cavity Insert Instructions The following instructions are intended for qualified service personnel ONLY, and should only be done when necessary. In order to replace the thermostat or heating element, remove the cavity insert crossbar by following the instructions below: Turn off the power to the water heater. Remove the jacket access panel or electronic control and insulation. Rotate the crossbar up and down until it breaks away from the remainder of the cavity insert. (See illustration to the left) Discard the crossbar. It cannot and need not be replaced. Replace the temperature sensor and/or element as necessary. Replace the insulation and jacket access panel/ electronic control before turning on the power to the water heater. NOTICE: The cavity insert crossbar is necessary for the manufacturing process only. The removal of the crossbar will not interfere with the operation of the water heater. 25 Wiring Diagram This water heater is wired as indicated in the schematic below. Use only a 2 wire power feed with ground connection for this water heater. 26 Notes: 27 Notes: 28 IF YOU NEED SERVICE 1. Should you have any questions about your new water heater, or if it requires adjustment, repair, or routine maintenance, it is suggested that you first contact your installer, plumbing contractor or previously agreed upon service agency. In the event the firm has moved, or is unavailable, refer to the telephone directory, commercial listings or local utility for qualified service assistance. 2. Should your problem not be solved to your complete satisfaction, you should then contact the Manufacturer’s National Service Department at the following address: 1241 Carwood Court Montgomery, Alabama 36117 Phone: 1-866-279-4566. When contacting the manufacturer, the following information will be requested: a. Model and serial number of the water heater as shown on the rating plate attached to the jacket of the heater. b. Address where the water heater is located and physical location. c. Name and address of installer and any service agency who performed service on the water heater. d. Date of original installation and dates any service work was performed. e. Details of the problems as you can best describe them. f. List of people, with dates, who have been contacted regarding your problem. Water Heaters Electric Residential The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water heater; and two, for the owner–operator, to explain the features, operation, safety precautions, maintenance and troubleshooting of the water heater. This manual also includes a parts list. It is imperative that all persons who are expected to install, operate or adjust this water heater read the instructions carefully so they may understand how to perform these operations. If you do not understand these instructions or any terms within it, seek professional advice. Any questions regarding the operation, maintenance, service or warranty of this water heater should be directed to the seller from whom it was purchased. If additional information is required, refer to the section on “If you need service.” Do not destroy this manual. Please read carefully and keep in a safe place for future reference. ! Recognize this symbol as an indication of Important Safety Information! ! California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm. with Electronic Control ® LISTED 786H AP16697-1 (10/13)Printed in USA Use & Care Manual With Installation Instructions for the Installer 2 Care and Cleaning Draining ................ 20 Maintenance ............. 20 Extended Shut-Down ..... 21 Safety Information Safety Precautions ....... 3, 4 Installation Instructions Location ................. 5 Water Connections ........ 6 Electrical Connections. . . . . . 8 Operating Instructions Safety Controls .......... 12 Water Temperature ........13 Electronic Control Operation . . . . . . . . . . . . . . .18 Troubleshooting Tips Before You Call For Service .............. 22 Customer Service Parts List ................ 23 Wiring Diagram ......... 25 If You Need Service ................. 28 FOR YOUR RECORDS Write the model and serial numbers here: # # You can find them on a label on the appliance. Staple sales slip or cancelled check here. Proof of the original purchase date is needed to obtain service under the warranty. Inside you will find many helpful hints on how to use and maintain your water heater properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your water heater. You’ll find many answers to common problems in the Before You Call For Service section. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all. READ THIS MANUAL Your safety and the safety of others are very important. There are many important safety messages in this manual and on your appliance. Always read and obey all safety messages. ! This is the safety alert symbol. Recognize this symbol as an indication of Important Safety Information! This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER”, “WARNING”, “CAUTION” or “NOTICE”. These words mean: ! DANGER An imminently hazardous situation that will result in death or serious injury. ! WARNING A potentially hazardous situation that could result in death or serious injury and/or damage to property. ! CAUTION A potentially hazardous situation that may result in minor or moderate injury. Notice: Attention is called to observe a specified procedure or maintain a specific condition. READ THE SAFETY INFORMATION 3 Time/Temperature Relationship in Scalds Temperature Time To Produce a Serious Burn 120°F More than 5 minutes 125°F 1½ to 2 minutes 130°F About 30 seconds 135°F About 10 seconds 140°F Less than 5 seconds 145°F Less than 3 seconds 150°F About 1½ seconds 155°F About 1 second Table courtesy of Shriners Burn Institute The chart shown above may be used as a guide in determining the proper water temperature for your home. ! DANGER: Households with small children, disabled, or elderly persons may require a 120°F or lower thermostat setting to prevent contact with “HOT” water. The temperature of the water in the heater is regulated by the electronic control and surface mounted temperature sensors. To comply with safety regulations the electronic control was programmed with a 120°F set point at the factory. DO NOT attempt to set the temperature by removing the electronic control or lower access panel. See the electronic control operation section of this manual. ! DANGER: Hotter water increases the potential for Hot Water SCALDS. DANGER ! HOT Water temperature over 125 °F can cause severe burns instantly or death from scalds. Children, disabled and elderly are at highest risk of being scalded. See instruction manual before setting temperature at water heater. Feel water before bathing or showering. Temperature limiting valves are available, see manual. BURN IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. DANGER! WATER TEMPERATURE SETTING Safety and energy conservation are factors to be considered when selecting the water temperature setting of water heater’s thermostat. Water temperatures above 125°F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined on the label pictured below. This label is also located on the water heater near the thermostat access panel. NOTICE: Mixing valves are available for reducing point of use water temperature by mixing hot and cold water in branch water lines. Contact a licensed plumber or the local plumbing authority for further information. 4 IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. Be sure to read and understand the entire Use and Care Manual before attempting to install or operate this water heater. It may save you time and cost. Pay particular attention to the Safety Instructions. Failure to follow these warnings could result in serious bodily injury or death. Should you have problems understanding the instructions in this manual, or have any questions, STOP, and get help from a qualified service technician, or the local electric utility. FOR INSTALLATIONS IN THE STATE OF CALIFORNIA California Law requires that residential water heaters must be braced, anchored or strapped to resist falling or horizontal displacement due to earthquake motions. For residential water heaters up to 52 gallon capacity, a brochure with generic earthquake bracing instructions can be obtained from: Office of the State Architect, 400 P Street, Sacramento, CA 95814 or you may call 916-324-5315 or ask a water heater dealer. However, applicable local codes shall govern installation. For residential water heaters of a capacity greater than 52 gallons, consult the local building jurisdiction for acceptable bracing procedures. READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS Have the installer show you the location of the circuit breaker and how to shut it off if necessary. Turn off the circuit breaker if the water heater has been subjected to overheating, fire, flood, physical damage or if the ECO fails to shut off. ● Read this manual entirely before installing or operating the water heater. ● Use this appliance only for its intended purpose as described in this Use and Care Manual. ● Be sure your appliance is properly installed in accordance with local codes and the provided installation instructions. ● DO NOT attempt to repair or replace any part of your water heater unless it is specifically recommended in this manual. All other servicing should be referred to a qualified technician. SAFETY PRECAUTIONS 5 Installing the water heater. The location chosen for the water heater must take into consideration the following: Local Installation Regulations This water heater must be installed in accordance with these instructions, local codes, utility codes, utility company requirements or, in the absence of local codes, the latest edition of the National Electrical Code. It is available from some local libraries or can be purchased from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269 as booklet ANSI/NFPA 70. Location Locate the water heater in a clean dry area as near as practical to the area of greatest heated water demand. Long un-insulated hot water lines can waste energy and water. Place the water heater in such a manner that the upper electronic control and the lower access panels can be removed to permit inspection and servicing such as removal of elements or checking controls. The water heater and water lines should be protected from freezing temperatures. Do not install the water heater in outdoor, unprotected areas. Make certain the floor underneath the water heater is strong enough to sufficiently support the weight of the water heater once it is filled with water. CAUTION: The water heater should not be located in an area where leakage of the tank or connections will result in damage to the area adjacent to it or to lower floors of the structure. Where such areas cannot be avoided, it is recommended that a suitable catch pan, adequately drained, be installed under the water heater. This water heater is supplied with a water detection system. It is recommended that the water heater be placed in a suitable catch pan and the water sensor rope be placed inside the catch pan. See water sensor section for further information. A— Diameter of water heater plus 2″ min. B— Maximum 2″ NOTICE: Auxiliary catch pan MUST conform to local codes. Catch Pan Kits are available from the store where the waterheater was purchased, or any water heater distributor. B A To open drain, line should be at least 3/4″ ID and pitched for proper drainage. Inspect Shipment Inspect the water heater for possible damage. Check the markings on the rating plate of the water heater to be certain the power supply corresponds to the water heater requirements. ! NOTICE: Do not install the water heater in attics where the temperature may exceed 150°F. 6 Installing the water heater. Typical Installation Thermal Expansion Determine if a check valve exists in the inlet water line. Check with your local water utility. It may have been installed in the cold water line as a separate back flow preventer, or it may be part of a pressure reducing valve, water meter or water softener. A check valve located in the cold water inlet line can cause what is referred to as a “closed water system”. A cold water inlet line with no check valve or back flow prevention device is referred to as an “open” water system. As water is heated, it expands in volume and creates an increase in the pressure within the water system. This action is referred to as “thermal expansion”. In an “open” water system, expanding water which exceeds the capacity of the water heater flows back into the city main where the pressure is easily dissipated. A “closed water system”, however, prevents the expanding water from flowing back into the main supply line, and the result of “thermal expansion” can create a rapid and dangerous pressure increase in the water heater and system piping. This rapid pressure increase can quickly reach the safety setting of the relief valve, causing it to operate during each heating cycle. Thermal expansion, and the resulting rapid and repeated expansion and contraction of components in the water heater and piping system can cause premature failure of the relief valve, and possibly the heater itself. Replacing the relief valve will not correct the problem! The suggested method of controlling thermal expansion is to install an expansion tank in the cold water line between the water heater and the check valve (refer to the illustration below). The expansion tank is designed with an air cushion built in that compresses as the system pressure increases, thereby relieving the over pressure condition and eliminating the repeated operation of the relief valve. Other methods of controlling thermal expansion are also available. Contact your installing contractor, water supplier or plumbing inspector for additional information regarding this subject. NOTICE: Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater. Any heat applied to the water supply fittings will permanently damage the dip tube and/or heat traps. Water Supply Connections Refer to the illustration below for suggested typical installation. The installation of unions or flexible copper connectors is recommended on the hot and cold water connections so that the water heater may be easily disconnected for servicing if necessary. The HOT and COLD water connections are clearly marked and are 3/4″ NPT on all models. Install a shut-off valve in the cold water line near the water heater. Vacuum Relief Valve (Not Supplied) If required, install per local codes and valve manufacturer’s instructions. To electric distribution panel Heat trap 6" minimum Auxiliary catch pan 2" maximum Drain Valve 6" air gap Relief valve discharge line to suitable open drain Thermal expansion tank (if required) Heat trap 6" minimum To cold water supply Hot water outlet to fixture Temperature & Pressure Relief Valve Electronic Control Lower Access Panel Electrical junction box (use only copper conductors) Shut-off valve Anode Union Union EcoNetTM Port 7 ! WARNING: The pressure rating of the relief valve must not exceed 150 PSI, the maximum working pressure of the water heater as marked on the rating plate. A new combination temperature and pressure relief valve, complying with the Standard for Relief Valves and Automatic Gas Shut-Off Devices for Hot Water Supply Systems, ANSI Z21.22, is supplied and must be installed in the opening provided and marked for the purpose on the water heater. No valve of any type should be installed between the relief valve and the tank. Local codes shall govern the installation of relief valves. Relief Valve The BTUH rating of the relief valve must not be less than the input rating of the water heater as indicated on the rating label located on the front of the heater (1 watt=3.412 BTUH). Connect the outlet of the relief valve to a suitable open drain so that the discharge water cannot contact live electrical parts or persons and to eliminate potential water damage. Piping used should be of a type approved for hot water distribution. The discharge line must be no smaller than the outlet of the valve and must pitch downward from the valve to allow complete drainage (by gravity) of the relief valve and discharge line. The end of the discharge line should not be threaded or concealed and should be protected from freezing. No valve of any type, restriction or reducer coupling should be installed in the discharge line. To Fill the Water Heater Make certain the drain valve is completely closed. Open the shut-off valve in the cold water supply line. Open each hot water faucet slowly to allow the air to vent from the water heater and piping. A steady flow of water from the hot water faucet(s) indicates a full water heater. ! WARNING: The tank must be full of water before heater is turned on. The water heater warranty does not cover damage or failure resulting from operation with an empty or partially empty tank. Condensation Condensation can form on the tank when it is first filled with water. Condensation might also occur with a heavy water draw and very cold inlet water temperature. This condition is not unusual, and will disappear after the water becomes heated. If, however, the condensation continues, examine the piping and fittings for possible leaks. EcoNetTM Communication Port EcoNetTM Communication port is for future integration with home automation, energy management, and demand response systems. 8 Installing the water heater. NOTICE: This guide recommends minimum branch circuit sizing and wire size based on National Electric Code. Refer to wiring diagrams in this manual for field wiring connections. Branch Circuit Sizing and Wire Size Guide CAUTION: The presence of water in the piping and water heater does not provide sufficient conduction for a ground. Non-metallic piping, dielectric unions, flexible connectors etc. can cause the water heater to be electrically isolated. Electrical Connections A separate branch circuit with copper conductors, overcurrent protective device and suitable disconnecting means must be provided by a qualified electrician. All wiring must conform to local codes or latest edition of National Electrical Code ANSI/NFPA 70. The water heater is completely wired to the junction box inside jacket at the top front of the water heater. An opening for 1/2″ or 3/4″ electrical fitting is provided for field wiring connections. The voltage requirements and wattage load for the water heater are specified on the rating plate on the front of the water heater. The branch circuit wiring should include either: Metallic conduit or metallic sheathed cable approved for use as a grounding conductor and installed with fittings approved for the purpose. Non-metallic sheathed cable, metallic conduit or metallic sheathed cable not approved for use as a ground conductor shall include a separate conductor for grounding. It should be attached to the ground terminals of the water heater and the electrical distribution box. Water heater junction box. WARNINGWARNI NG Junction box cover Wire connections Ground screw Conduit connector Single Phase Wiring Total Water Heater Wattage Recommended Over Current Protection (fuse or circuit breaker amperage rating) Copper Wire Size AWG Based on N.E.C Table 310-16 (75oC) 208V 240V 208V 240V 3,000 20 20 12 12 4,000 25 25 10 10 4,500 30 25 10 10 5,000 30 30 10 10 5,500 35 30 8 10 ! 9 For increased energy efficiency, some water heaters have been supplied with two 24” sections of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements. Typical vertical piping arrangement Typical horizontal piping arrangement Hot and Cold Pipe Insulation Installation Insulation blankets, available to the general public, for external use on electric water heaters are not necessary. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. This water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements making an insulation blanket unnecessary. The manufacturer’s warranty does not cover any damage or defect caused by installation, attachment or use of any type of energy saving or other unapproved devices (other than those authorized by the manufacturer) into, onto or in conjunction with the water heater. The use of unauthorized energy saving devices may shorten the life of the water heater and may endanger life and property. The manufacturer disclaims any responsibility for such loss or injury resulting from the use of such unauthorized devices. !CAUTION: If local codes require the application of an external insulation blanket to this water heater, pay careful attention to the following so as not to restrict the proper function and operation of the water heater:  Do not cover the operating or warning labels attached to the water heater or attempt to relocate them on the exterior of insulation blanket.  Do not apply insulation to the top of the water heater. This could interfere with the safe operation of the electrical junction box.  Do not cover the jacket access panel(s) to the thermostat(s) and heating element(s), or pressure and temperature relief valve.  Inspect the insulation blanket frequently. !WARNING: If local codes require external application of insulation blanket kits the manufacturer’s instructions included with the kit must be carefully followed. Insulation Blankets 10 Installing the water heater. For increased energy efficiency, some water heaters have been supplied with a 2-3/8” section of pipe insulation. Please install the insulation, according to the illustrations above, that best meets your requirements. Slip the insulation cover over the T&P Valve through the center hole and align the hole in the side with the opening of the T&P Valve. Typical top connection arrangement Typical side connection arrangement Relief Valve Insulation Installation ! CAUTION: Ensure the T&P Valve opening is not obstructed by the insulation. Heat Trap For increased energy efficiency, some water heaters have been supplied with factory installed internal or external heat traps in the hot outlet and cold water inlet openings. NOTICE: Do not apply heat to the HOT or COLD water connections. If sweat connections are used, sweat tubing to adapter before fitting adapter to the water connections on heater. Any heat applied to the water supply fittings will permanently damage the dip tube and/ or heat traps. Water Sensor In order to detect the presence of unwanted water, this water heater is supplied with a built-in water sensing circuit. The water sensor rope is shipped in the warranty bag for field installation. Remove water sensor rope from the bag and attach to the connector located near the lower access panel. Place the rope in the recommended catch pan and secure to the pan bottom with provided self adhesive clips. When water is detected, the electronic control will turn off the heating elements, flash the display backlight and turn on an audible alarm. Water Sensor Rope Attachment Point Clips Catch Pan 11 Installation Checklist A. Water Heater Location B. Water Supply C. Relief Valve D. Wiring ❑ Close to area of heated water demand. ❑ Indoors and protected from freezing temperatures. ❑ Area free of flammable vapors. ❑ Provisions made to protect area from water damage. ❑ Sufficient room to service heater. ❑ Water heater completely filled with water. ❑ Air purged from water heater and piping. ❑ Water connections tight and free of leaks. ❑ Temperature and Pressure Relief Valve properly installed and discharge line run to open drain. ❑ Discharge line protected from freezing. ❑ Power Supply voltage agrees with water heater rating plate. ❑ Branch circuit wire and fusing or circuit breaker of proper size. ❑ Electrical connections tight and unit properly grounded. E. Water Sensor ❑ Water heater in catch pan ❑ Water sensor rope connected to heater ❑ Water sensor rope inside catch pan and secured with clip 12 Safety Precautions Do turn off power to water heater if it has been subjected to over heating, fire, flood, physical damage. Do Not turn on water heater unless it is filled with water. Do Not turn on water heater if cold water supply shut-off valve is closed. If there is any difficulty in understanding or following the Operating Instructions or the Care and Cleaning section, it is recommended that a qualified person or serviceman perform the work. Operating the water heater. CAUTION: Hydrogen gas can be produced in a hot water system served by this water heater that has not been used for a long period of time (generally two weeks or more). HYDROGEN GAS IS EXTREMELY FLAMMABLE!! To dissipate such gas and to reduce risk of injury, it is recommended that the hot water faucet be opened for several minutes at the kitchen sink before using any electrical appliance connected to the hot water system. If hydrogen is present, there will be an unusual sound such as air escaping through the pipe as the water begins to flow. Do not smoke or use an open flame near the faucet at the time it is open. Safety Controls The water heater is equipped with a temperature sensor and temperature limiting control (ECO) that is located above the upper heating element in contact with the tank surface. If for any reason the water temperature becomes excessively high, the temperature limiting control (ECO) breaks the power circuit to the heating element. Once the control opens, it must be reset manually. CAUTION: The cause of the high temperature condition must be investigated by qualified service technician and corrective action must be taken before placing the water heater in service again. To reset the temperature limiting control: Turn off the power to the water heater. Remove the electronic control and insulation. The thermostat protective cover should not be removed. Press the red RESET button. Replace the insulation and electronic control before turning on the power to the water heater. Reset button Thermostat protective cover WARNING: If the water heater has been subjected to flood, fire, or physical damage, turn off power and water to the water heater. DO NOT operate the water heater again until it has been thoroughly checked by qualified service personnel. 13 Water Temperature Time/Temperature Relationship in Scalds Temperature Time To Produce a Serious Burn 120°F More than 5 minutes 125°F 11/2 to 2 minutes 130°F About 30 seconds 135°F About 10 seconds 140°F Less than 5 seconds 145°F Less than 3 seconds 150°F About 11/2 seconds 155°F About 1 second Table courtesy of Shriners Burn Institute ! DANGER: There is a hot water scald potential if the thermostat is set too high. Households with small children, disabled, or elderly persons may require a 120°F or lower thermostat setting to prevent contact with HOT water. Water Temperature Set Point Safety and energy conservation are factors to be considered when selecting the water temperature setting of the water heater’s thermostat(s). The lower the temperature setting, the greater the savings in energy and operating costs. To comply with safety regulations the electronic control is factory programmed at 120°F or less where local codes require. This is the recommended starting point. Water temperatures above 125°F can cause severe burns or death from scalding. Be sure to read and follow the warnings outlined in this manual and on the label on the water heater. This label is located on the water heater above the lower access panel. Mixing valves for reducing point of use water temperature by mixing hot and cold water in branch water lines are available. Contact a licensed plumber or the local plumbing authority for further information. The electronic control allows the water temperature to be set from 110°F to 150°F. The chart below may be used as a guide in determining the proper water temperature for your home. 14 POWERING ON WATER HEATER SETTING WATER TEMPERATURE LOCKING THE SCREEN or Lock Icon *Note: If screen is dimmed press any buton and release to brighten the display before performing desired acton. Press and hold the On/Off buton for 3 seconds to turn the water heater On Reduce Water Temperature: Press DOWN arrow untl desired temperature is shown on display. Increase Water Temperature: Press UP arrow untl desired temperature is shown on display. Press and hold both arrow butons for 3 seconds to LOCK the control. Locking will reduce chance of unintentonal changes in water temperature. Programming the Electronic Control 15 VACATION SETTING ON VACATION SETTING OFF UNLOCKING THE SCREEN Lock Icon HEATING STATUS SCROLLING DOT When a dot scrolls between the numbers, this means that the heatng element is on. Press and hold both arrow butons for 3 seconds to UNLOCK the control. *Note: If screen is dimmed press any buton and release to brighten the display before performing desired acton. Press and hold the VACATION buton for 3 seconds to place the water heater in vacaton mode. This mode will reduce the water temperature to save energy during tmes when hot water is not needed. Press and hold the VACATION buton for 3 seconds to remove the water heater from vacaton mode. This will return the temperature setng to the previous set point before initatng vacaton mode. 16 CONFIGURATION MENU – MODE – CONFIGURE – STATUS – HISTORY PRESS TO SELECT ENERGY SAVER – HIGH TEMP DISPLAY – BEEP – INSTANCE MODE CONFIGURE PRESS TO SELECT Press and release the MENU/SELECT buton to enable the configuraton menu. Use UP/DOWN arrow butons to scroll through the available configuraton setngs. Press MENU/SELECT buton to choose the desired menu item. See below for further optons. The MODE menu is used to change the water heater from PERFORMANCE mode to ENERGY SAVER mode. Use DOWN arrow to change the mode. The CONFIGURE menu is used to change additonal setngs for the water heater performance and display optons. Press the DOWN arrow buton to scroll through the available setngs. Press MENU/SELECT buton to choose the desired configuraton opton. See following sheet for explanaton for each configuraton setng. *Note: If screen is dimmed press any buton and release to brighten the display before performing desired acton. VERSION INFORMATION– – – Programming the Electronic Control 17 CHANGE CHANGE SCROLL DISPLAY BEEP INSTANCE – NO -YES PRESS TO SELECT HIGH TEMPERATURE High temperature mode will allow the water temperature to be set above 140 degrees F. Press the DOWN arrow to change setng then press SELECT. *Note: If screen is dimmed press any buton and release to brighten the display before performing desired acton. Display mode is used to change the temperature displayed from Fahrenheit to Celsius. Press either UP or DOWN arrow to change. Beep mode is use to turn all the audible alarms on and off. Press either UP or DOWN arrow to change. In this mode, error alarms and water sensor detecton alarms will not occur. Instance number is used to identfy the water heater if additonal water heaters or devices are connected to a joint home control system. The number may be changed from 1 to 16 to identfy this water heater. 18 Programming the Electronic Control –HEAT –UPPER TEMP –LOWER TEMP SCROLL PRESS TO SELECT STATUS HISTORY Use DOWN arrow to scroll through the menu. Press MENU/SELECT buton to actvate menu item. HEAT will display if an element is on or off. Choosing UPPER or LOWER TEMP will display the current temperature reading for that sensor. History menu lists the 10 most recent error codes. Use the DOWN arrow to scroll the codes. ERROR DISPLAY ERROR SYMBOL History menu lists the 10 most recent error codes. Press the BACK/STATUS buton to show the most recent error code. Use the DOWN arrow to scroll the codes. See following sheet for all error codes, scrolling messages and recommended acton. *Note: If screen is dimmed press any buton and release to brighten the display before performing desired acton. 19 CODE SCROLLING MESSAGE DESCRIPTION/ACTION A100 Lower temperature thermistor failure Electronic control has detected lower temperature sensor is bad. The problem could be the sensor, wiring, or the control board. Please call for service. A101 Upper temperature thermistor failure Electronic control has detected upper temperature sensor is bad. The problem could be the sensor, wiring, or the control board. Please call for service. A102 Water sensor alarm Electronic control has detected water in the drain pan. Check the pan for water. If there is no water present, disconnect the sensor, dry and reinstall it to reset the error. A103 Fill tank with water Electronic control has detected no water in the tank. Please fill the tank with water and recycle power. A104 Emergency cut off alarm Electronic control has detected high temperature electrical cut-out device (ECO) has been activated. Reset ECO or call for service A105 Lower element error Electronic control has detected an error with the lower element or associated wiring and connections. Please call for service. A106 Upper element error Electronic control has detected an error with the upper element or associated wiring and connections. Please call for service. A107 Element wire routing error Call for service A108 Lower element relay stuck on error If this error is displayed, the control board will have to be replaced. Please call customer service. A109 Upper element relay stuck on error If this error is displayed, the control board will have to be replaced. Please call customer service. A110 Lower temperature conversion error If this error is displayed, the control board will have to be replaced. Please call customer service. A111 Upper temperature conversion error If this error is displayed, the control board will have to be replaced. Please call customer service. A500 Control Failure If this error is displayed, the control board will have to be replaced. Please call customer service. Error Codes for Electronic Control ERROR CODES CAUTION: For your safety DO NOT attempt repair of electrical wiring, temperature sensor, electronic control, heating elements or other safety devices. Refer repairs to qualified service personnel. ! 20 Care and cleaning of the water heater. Draining the Water Heater CAUTION: Shut off power to the water heater before draining water. DANGER: Before manually operating the relief valve, make certain no one will be exposed to the hot water released by the valve. The water drained from the tank may be hot enough to present a scald hazard and should be directed to a suitable drain to prevent injury or damage. In order to drain the water heater, turn off the cold water supply. Open a hot water faucet or lift the handle on the relief valve to admit air to the tank. Attach a garden hose to the drain valve on the water heater and direct the stream of water to a drain. Open the valve. Routine Preventative Maintenance Properly maintained, your water heater will provide years of dependable trouble- free service. It is suggested that a routine preventive maintenance program be established and followed by the user. It is further recommended that a periodic inspection of the operating controls, heating element and wiring should be made by service personnel qualified in electric appliance repair. Most electrical appliances, even when new, make some sound when in operation. If the hissing or singing sound level increases excessively, the electric heating element may require cleaning. Contact a qualified installer or plumbing contract to inspect. At least once a year, lift and release the lever handle on the temperature pressure relief valve, located near the top of the water heater, to make certain the valve operates freely. Allow several gallons to flush through the discharge line to an open drain. A water heater’s tank can act as a setting basin for solids suspended in the water.It is therefore not uncommon for hard water deposits to accumulate in the bottom of the tank. It is suggested that a few quarts of water be drained from the water heater’s tank every month to clean the tank of these deposits. Rapid closing of faucets or solenoid valves in automatic water using appliances can cause a banging noise heard in a water pipe. Strategically located risers in the water pipe system or water hammer arresting devices can be used to minimize the problem. The anode rod should be removed from the water heater’s tank annually for inspection and replaced when more than 6″ of core wire is exposed at either end of the rod. Make sure the cold water supply is turned off before removing anode rod. DANGER: Before manually operating the relief valve, make certain no one will be exposed to the danger of coming in contact with the hot water released by the valve. The water may be hot enough to create a scald hazard. The water should be released into a suitable drain to prevent injury or property damage. NOTICE: If the temperature and pressure relief valve on the hot water heater discharges periodically, this may be due to thermal expansion in a closed water system. Contact the water supplier or your plumbing contractor on how to correct this. Do not plug the relief valve outlet. 21 Care and cleaning of the water heater. Extended Shut-Down If the water heater is to remain idle for an extended period of time, the power and water to the appliance should be turned off to conserve energy and prevent a build-up of dangerous hydrogen gas. The water heater and piping should be drained if they might be subjected to freezing temperatures. After a long shut-down period, the water heater’s operation and controls should be checked by qualified service personnel. Make certain the water heater is completely filled again before placing it in operation. NOTICE: Refer to the Hydrogen Gas Caution in the Operating Instructions. Anode Rod This water heater is equipped with an anode rod designed to prolong the life of the glass lined tank. The anode rod is slowly consumed, thereby eliminating or minimizing corrosion of the glass lined tank. Water sometimes contains a high sulfate and/or mineral content and together with cathodic protection process can produce a hydrogen sulfide, or rotten egg odor in the heated water. Chlorination of the water supply should minimize the problem. NOTICE: Do not remove the anode rod from the water heater’s tank, except for inspection and/or replacement, as operation with the anode rod removed will greatly shorten the life of the glass lined tank and will exclude warranty coverage. 22 Before You Call For Service… Troubleshooting Tips Save time and money! Review the chart on this page first and you may not need to call for service. CAUTION: For your safety DO NOT attempt repair of electrical wiring, temperature sensor, electronic control, heating elements or other safety devices. Refer repairs to qualified service personnel. ! Problem Possible Causes What To Do Rumbling noise Water conditions in your home caused a build up of scale or mineral deposits on the heating elements. ● Remove and clean the heating elements. Relief valve producing popping noise or draining Pressure build up caused by thermal expansion in a closed system. ● This is an unacceptable condition and must be corrected. Contact the water supplier or plumbing contractor on how to correct this. Do not plug the relief valve outlet. Rattling noise during periods of water usage Internal heat trap fittings in operation. ● This is normal for heat trap fittings when in operation and does not indicate a need for service. Not enough or no hot water Water usage may have exceeded the capacity of the water heater. ● Wait for the water heater to recover after an abnormal demand. A fuse is blown or a circuit breaker tripped. ● Replace fuse or reset circuit breaker. Electric supply may be off. ● Make sure electric supply to water heater and disconnect switch, if used, are in the ON position. The thermostat may be set set too low. ● See the Temperature regulation of the water heater sec- tion of this manual. Leaking or open hot water faucets. ● Make sure all faucets are closed. Electric service to your home may be interrupted. ● Contact the local electric utility. Improper wiring. ● See the Installing the water heater section of this manual. Manual reset limit (ECO). ● See the Temperature regulation of the water heater sec- tion of this manual. Cold water inlet temperature may be colder during the winter months. ● This is normal. The colder inlet water takes longer to heat. Water is too hot The thermostat is set too high. ● See the Temperature regulation of the water heater sec- tion of this manual. Cannot set above 140°F Electronic control high temp configuration set to NO. ● See configuration menu section on programming the electronic control. 23 Replacement Parts. For 20–120 gallon models with single and double elements. Instructions For Placing a Parts Order Address parts orders to the distributor or store where the heater was purchased. All parts orders should include: The model and serial number of the water heater from the rating plate. Specify voltage and wattage as marked on the rating plate. Part description (as noted below) and number of parts desired. ! CAUTION: For your safety DO NOT attempt repair of electrical wiring, thermostat(s), heating elements or other operating controls. Refer repairs to qualified service personnel. Some models may have been supplied with External heat traps in lieu of Internal heat traps Electronic Control Cavity insulation Upper thermostat protective cover ECO with upper sensor Jacket access panel Thermostat bracket Drain valve Lower sensor Heating Element Heating element gasket Plate cover Junction box cover Anode rod Dip tube gasket Dip tube / internal heat trap Temperature & Pressure Relief Valve Internal heat trap Internal heat trap gasket Upper thermostat bracket Heating element Heating element gasket Water Sensor Connector 24 Cavity Insert Instructions The following instructions are intended for qualified service personnel ONLY, and should only be done when necessary. In order to replace the thermostat or heating element, remove the cavity insert crossbar by following the instructions below: Turn off the power to the water heater. Remove the jacket access panel or electronic control and insulation. Rotate the crossbar up and down until it breaks away from the remainder of the cavity insert. (See illustration to the left) Discard the crossbar. It cannot and need not be replaced. Replace the temperature sensor and/or element as necessary. Replace the insulation and jacket access panel/ electronic control before turning on the power to the water heater. NOTICE: The cavity insert crossbar is necessary for the manufacturing process only. The removal of the crossbar will not interfere with the operation of the water heater. 25 Wiring Diagram This water heater is wired as indicated in the schematic below. Use only a 2 wire power feed with ground connection for this water heater. 26 Notes: 27 Notes: 28 IF YOU NEED SERVICE 1. Should you have any questions about your new water heater, or if it requires adjustment, repair, or routine maintenance, it is suggested that you first contact your installer, plumbing contractor or previously agreed upon service agency. In the event the firm has moved, or is unavailable, refer to the telephone directory, commercial listings or local utility for qualified service assistance. 2. Should your problem not be solved to your complete satisfaction, you should then contact the Manufacturer’s National Service Department at the following address: 1241 Carwood Court Montgomery, Alabama 36117 Phone: 1-866-279-4566. When contacting the manufacturer, the following information will be requested: a. Model and serial number of the water heater as shown on the rating plate attached to the jacket of the heater. b. Address where the water heater is located and physical location. c. Name and address of installer and any service agency who performed service on the water heater. d. Date of original installation and dates any service work was performed. e. Details of the problems as you can best describe them. f. List of people, with dates, who have been contacted regarding your problem. 10/17 FORM NO. THD-PPE12 N Rev. 7 PERFORMANCE PLATINUM High Efficiency 40, 50 and 55-Gallon Capacities 240 Volt AC/Single Phase LEED Point = 1 See specifications chart on back. PERFORMANCE PLATINUM™ High Efficiency electric water heaters are engineered for longer life, high performance and lower operating cost Efficiency  .92 - .93 UEF  Dual 4500 or 5500 watt stainless steel heating elements on models with PlusOne™ Water Management System  Dual 4500 watt copper heating elements on 50-gallon tall and 40-gallon medium models without PlusOne™ Water Management System Performance  FHR: 55 - 72 gallons, based on gallon capacity  Recovery: 21 to 25 GPH at a 90° F rise, depending on model** PlusOne™ Water Management System  Simple easy to read diagnostics  Controls multiple operating modes  Digital thermostat setting  Leak detection with audible alarm  EcoNet® enabled for integration with home automation, energy management and demand response systems Longer Life  Premium grade anode rod provides long-lasting tank protection Self Cleaning  Fights sediment build-up  Saves energy Features  High performance and lower operating cost  Compliant with many electric utility incentive programs  Electric junction box located above heating elements for easy installation  Over-temperature protector cuts off power in excess temperature situations Plus…  Durable brass drain valve  Temperature and pressure relief valve included  Low lead compliant Warranty  12-Year limited warranty for tank and parts, 3-year full in-home labor warranty* *See written warranty for complete details Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. Fuel Type Description Nominal Gallon Capacity Rated Gallon Capacity Model Number Recovery in G.P.H. 90° F Rise First Hour Rating G.P.H. Tank Height A Height to Water Conn. B Diameter C Ship Weight (LBS.) Uniform Energy Factor (UEF) With PlusOne™ Management System Electric Tall 55 55 XE55T12EC55U0 25 72 57 59-3/4 22-1/4 128 0.93 Electric Tall 55 55 XE55T12EC45U0 21 72 57 59-3/4 22-1/4 128 0.92 Electric Tall 50 45 XE50T12EC55U1 25 63 58-3/8 61-5/8 20-1/4 121 0.93 Electric Tall 50 45 XE50T12EC45U0 21 63 58-3/8 61-5/8 20-1/4 121 0.93 Electric Medium 50 45 XE50M12EC55U1 25 63 48 50-1/2 22-1/4 127 0.93 Electric Medium 50 45 XE50M12EC45U0 21 63 48 50-1/2 22-1/4 127 0.93 Electric Medium 40 36 XE40M12EC55U1 25 55 48-3/8 50-1/2 20-1/4 106 0.93 Electric Medium 40 36 XE40M12EC45U0 21 55 48-3/8 50-1/2 20-1/4 106 0.93 Standard Without PlusOne™ Management System Electric Tall 50 45 XE50T12ST45U1 21 63 58-5/8 61-5/8 20-1/4 121 0.93 Electric Medium 50 45 XE50M12ST45U1 21 59 48 50-1/2 23 132 0.93 Electric Medium 40 36 XE40M12ST45U1 21 54 48-1/4 50-1/4 20-1/4 106 0.93 High Efficiency Specifications 10/17 FORM NO. THD-PPE12 N Rev. 7 In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com CDIAMETER A B HOTWATERCONNECTION COLD WATERCONNECTION ANODE ROD RELIEF VALVE CONNECTION 8" WATER CONNECTIONS ALL 3/4" N.P.T. **Recovery = wattage/2.42 x temp. rise °F. Example: 5500W = 25 GPH 2.42 x 90° Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. • Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 4500 or 5500 watt upper and lower heating elements. * *Recovery calculations used are based on 5500 watt elements used in non-simultaneous operation. LEED Point = 1 10/17 FORM NO. THD-PPE12 N Rev. 7 PERFORMANCE PLATINUM High Efficiency 40, 50 and 55-Gallon Capacities 240 Volt AC/Single Phase LEED Point = 1 See specifications chart on back. PERFORMANCE PLATINUM™ High Efficiency electric water heaters are engineered for longer life, high performance and lower operating cost Efficiency  .92 - .93 UEF  Dual 4500 or 5500 watt stainless steel heating elements on models with PlusOne™ Water Management System  Dual 4500 watt copper heating elements on 50-gallon tall and 40-gallon medium models without PlusOne™ Water Management System Performance  FHR: 55 - 72 gallons, based on gallon capacity  Recovery: 21 to 25 GPH at a 90° F rise, depending on model** PlusOne™ Water Management System  Simple easy to read diagnostics  Controls multiple operating modes  Digital thermostat setting  Leak detection with audible alarm  EcoNet® enabled for integration with home automation, energy management and demand response systems Longer Life  Premium grade anode rod provides long-lasting tank protection Self Cleaning  Fights sediment build-up  Saves energy Features  High performance and lower operating cost  Compliant with many electric utility incentive programs  Electric junction box located above heating elements for easy installation  Over-temperature protector cuts off power in excess temperature situations Plus…  Durable brass drain valve  Temperature and pressure relief valve included  Low lead compliant Warranty  12-Year limited warranty for tank and parts, 3-year full in-home labor warranty* *See written warranty for complete details Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. Fuel Type Description Nominal Gallon Capacity Rated Gallon Capacity Model Number Recovery in G.P.H. 90° F Rise First Hour Rating G.P.H. Tank Height A Height to Water Conn. B Diameter C Ship Weight (LBS.) Uniform Energy Factor (UEF) With PlusOne™ Management System Electric Tall 55 55 XE55T12EC55U0 25 72 57 59-3/4 22-1/4 128 0.93 Electric Tall 55 55 XE55T12EC45U0 21 72 57 59-3/4 22-1/4 128 0.92 Electric Tall 50 45 XE50T12EC55U1 25 63 58-3/8 61-5/8 20-1/4 121 0.93 Electric Tall 50 45 XE50T12EC45U0 21 63 58-3/8 61-5/8 20-1/4 121 0.93 Electric Medium 50 45 XE50M12EC55U1 25 63 48 50-1/2 22-1/4 127 0.93 Electric Medium 50 45 XE50M12EC45U0 21 63 48 50-1/2 22-1/4 127 0.93 Electric Medium 40 36 XE40M12EC55U1 25 55 48-3/8 50-1/2 20-1/4 106 0.93 Electric Medium 40 36 XE40M12EC45U0 21 55 48-3/8 50-1/2 20-1/4 106 0.93 Standard Without PlusOne™ Management System Electric Tall 50 45 XE50T12ST45U1 21 63 58-5/8 61-5/8 20-1/4 121 0.93 Electric Medium 50 45 XE50M12ST45U1 21 59 48 50-1/2 23 132 0.93 Electric Medium 40 36 XE40M12ST45U1 21 54 48-1/4 50-1/4 20-1/4 106 0.93 High Efficiency Specifications 10/17 FORM NO. THD-PPE12 N Rev. 7 In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice. Rheem Water Heating • 1115 Northmeadow Parkway, Suite 100 Roswell, Georgia 30076 • www.rheem.com CDIAMETER A B HOTWATERCONNECTION COLD WATERCONNECTION ANODE ROD RELIEF VALVE CONNECTION 8" WATER CONNECTIONS ALL 3/4" N.P.T. **Recovery = wattage/2.42 x temp. rise °F. Example: 5500W = 25 GPH 2.42 x 90° Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. • Heaters furnished with standard 240 volt AC, single phase non-simultaneous wiring, and 4500 or 5500 watt upper and lower heating elements. * *Recovery calculations used are based on 5500 watt elements used in non-simultaneous operation. LEED Point = 1