Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
F18-0068_Approved Documents_1539701660.pdf
75 South Frontage Road Fire-Construction Permit West, TOWN OFVAIL F18-0068 Vail,CO 81657 Issued: 10/16/2018 TOWN of VAIL0.ZOffice:970.479.2139 Inspections: inspections@vailgov.com Property Information Address: 1965 SUNBURSTDR(210109103003) (210109103003 ) Unit#: ParcelNumber: 210109103003 LegalDescription: Subdivision:VAILVALLEY3RD FILING Lot:11 R899269DEC 12-01-04 Contacts ContactType:Applicant Full Name:Raymond Gibler Address: 107 Central Ave Wiggins,CO 80654 Phone: 3035945848 ContactType:PropertyOwner Full Name:HANS G.STORRREVOCABLE TRUST Address: Phone: None Contractor Contractor Type:Fire Protection Company: All-state Fire Protectionlnc State License#: Phone: 303-288-3901 Projecllnformation ProjectName:StorrResidence2018 ProjectDescription: Fire suppressionsystem forresidential Fees Paid Accounl#:001-0000.31111.0 a Fire Suppression Permit Fee Fee Amount: $850.00 Accounl#:001-0000.31123.00 Fire SuppressionReviewFee Fee Amount: $432.00 TotalPaid: $1,282.00 Conditions Issued By:Town of Vail Fire and EmergencyServices Department NOTICE: By issuance of this Permitthe applicant agrees to complyto all Titles of the Townof Vail Code and all applicable State and Federal law.Failure to do so will void this Permit and the applicant shall forfeitall applicable fees. PERMIT FEE RECEIPT TOWN OF VAIL Case # F 18-0068 Date Printed: 09/19/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: F18-0068 Status: Created Permit Number: Date Started: 09/19/2018 Permit Type: Fire-Construction Permit Subc ases Fire Suppression Lot Number: 11 Property: 1965 SUNBURST DR (210109103003)(210109103003) Contacts Contact Type: Applicant Company Name: All-State Fire Protection Full Name: Raymond Gibler Address: 107 Central Ave Wiggins, CO 80654 Email: amberh@allstatefireprotection.com Contact Type: Property Owner Full Name: HANS G. STOR R REVOCABLE TR UST Address: Permit Fees Fee Information Account Amount Fire Suppression Permit Fee 001-0000.31111.00 $850.00 Fire Suppression Review Fee 001-0000.31123.00 $432.00 Payment Information Date Paid Payment Type Amount Fire Suppression Review Fee 09/19/2018 Credit Card $432.00 Paid By: -Notes:MC-All State Fire Protection Fire Suppression Permit Fee 09/19/2018 Credit Card $850.00 Paid By: -Notes:MC-All State Fire Protection FEE TOTAL $1,282.00 AMOUNT PAID $1,282.00 BALANCE DUE $0.00 75 South Frontage Road West,Vail,Colorado 81657 09/19/2018-8:57:07 AM-Generated by:do ouc h 1/1 Hydraulic Overview JobNumber:1 ResortDescri•tion:Residential Job Number Design Engineer 1 AL BRUCH Job Name: Phone FAX WILSON RESIDENCE Address 1 State Certification/License Number 1965 SUNBURST DRIVE Address 2 AHJ VAIL,CO 8165 7 Address 3 Job Site/Building Density Area of Application 0.100gpm/ft2 900.00ft2(Actual 223.92ft2) Most Demanding Sprinkler Data Hose Streams 4.3 K-Factor 13.00 at 9.140 0.00 Coverage Per Sprinkler Number Of Sprinklers Calculated 25 6.00ft2 3 System Pressure Demand System Flow Demand 78.246 42.78 Total Demand Pressure Result 42.78 @ 78.246 +4.260(5.2%) Supplies Check Point Gauges Node Name Flow(gpm) Hose Flow(gpm) Static(psi) Residual(psi) Identifier Pressure(psi) K-Factor(K) Flow(gpm) 19 Water Supply 50.00 90.000 80.000 15 40.00 Pump 48.000 45.000 ALAN W. BRUCH NICET LEVEL III WATER BASED SYSTEMS CERTIFICATION NO. 108440 EXPIRES JUNE 2021 SEPTEMBER 11, 2018 SIGNATURE Pumps:Static=Churn(Pressure @ Zero Flow) 18018 WILSON RESIDENCE FP Water Supply at Node 19(50.00,0.00,90.000,80.000) 100 _I 90 Static Pressure 90.000 xx- 8 8 80 50.00 @ 80.000 BA• J" r 42.78 @ 78.246 ant70 • 1 =i •(.7) 60 h- 50 System demand curve - `' s o a 40 • 20 10 0 IIllllllUlulll luu u l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l 111111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1020 30 40 50 60 70 80 90 100 Water flow,gpm ©M.E.P.CAD,Inc. AutoSPRINK®12 v12.0.5 9.0 9/11/2018 12:25:09PM Page 1 Hydraulic Graph Job Number:1 - Report Description:Residential Water Supply at Node 19 100 90 Static Pressure 90.000 80 50.00 @ 80.000 42.78 @ 78.246 70 60 Q 50 System demand curve w a, a 40 30 20 10 — 0 nn 1omu1 111111111 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 I I I I I I I I I 1 1 1 1 1 1 1 1 1 I I I I I I I I I I I I I I I I I I 1 1 1 1 1 1 1 1 1 010 20 3040 50 60 70 80 90 100 Water flow,gpm Hydraulic Graph WaterSupply at Node 19 Static:Pressure 90.000 Residual:Pressure 80.000 @ 50.00 Available Pressure at Time of Test 82.506 @ 42.78 system Demase 78.246 @ 42.78 System Demand(including Hose Allowance at Source) 78.246 @ 42.78 �4 ©M.E.P.CAD,Inc. M AutoSPRINK®12 v12.0.59.0 9/11/2018 12:25:15PM Page 2 Hydraulic Graph Job Number:1 Report Description:Residential Pump at Node 15 150 Combined Static Pressures 135 120 105 90 Supply Ul Q 75 `ump and Supply 42.78@70.168 a 60 Pump Churn Pressure 48.000 45 System(demand curvc 80.00 @ 38.000 30 15 0 iiiiiiiiiiiiiiii 111111 I I I iii i i i i i i 11111 1 I I i 0 9 1827 36 45 54 63 72 81 90 Water flow,gpm Hydraulic Graph Static+Churn Pressure Rated Pump Pressure Pump at Node 15 138.000 45.000 @ 40.00 Static:Pressure Churn Pressure 90.000 48.000 Residual:Pressure 80.000 @ 50.00 Available Pressure at Time of Test Available Pressure at Pump Discharge 82.506 @ 42.78 74.428 @ 42.78 system oemase 70.168 @ 42.78 �4 ©M.E.P.CAD,Inc. AutoSPRINK®12 v12.0.59.0 9/11/2018 12:25:15PM Page 3 i Summary Of Outflowing Devices Job Number:1 !:t +• - Report Description:Residential Actual Flow Minimum Flow K-Factor Pressure Device (qpm) (qpm) (K) (psi) Ets Sprinkler 101 13.00 13.00 4.3 9.140 Sprinkler 102 13.02 13.00 4.3 9.171 Sprinkler 103 16.76 13.00 4.3 15.187 * Most Demanding Sprinkler Data E,©M.E.P.CAD,Inc. 1111 AutoSPRINK®12 v12.0.59.0 9/11/2018 12:25:18PM Page 4 1'_ Node Analysis Job Number:1 Report Description:Residential Node Elevation(Foot) Fittings Pressure(psi) Discharge(gpm) 19 -0'-2'% S 78.246 42.78 101 40'-4'% Spr(-9.140) 9.140 13.00 102 40'-5 Spr(-9.171) 9.171 13.02 103 35'-7% Spr(-15.187) 15.187 16.76 1 40'-9% T(4'-0),Tr(0'-6) 9.817 2 30'-0 T(2'-0),Tr(0'-6) 19.480 3 18'-3 E(2'-)) 26.449 4 19'-9 T(2'-0),Tr(0'-6) 28.244 5 19'-9 T(2'-0) 36.341 6 9'-6 E(2'-0) 44.973 7 9'-6 E(2'-0) 51.043 8 9'-0 T(3'-0) 51.430 9 9'-0 T(3'-0) 52.652 10 9'-0 T(3'-0) 54.433 11 9'-0 T(3'-0) 55.277 12 9'-0 T(3'-0) 56.958 13 9'-0 T(3'-0) 59.479 14 9'-6 E(2'-0) 62.732 15 -0'-3'% P2(-44.644) 70.168 16 -0'-2% P1 25.494 17 -0'-2'% T(6-0) 25.539 18 -0'-2'% E(2'-0) 38.898 20 40'-9% E(2'-)) 9.482 21 36-0'/2 T(4'-0) 16.372 22 30'-0 T(2'-0) 22.079 23 18'-3 E(2'-0) 28.003 L©M.E.P.CAD,Inc. 15 AutoSPRINK®12 v12.0.59.0 9/11/2018 12:25:21PM Page 5 Job Number:1 iiiHydraulic Analysis Report Description:Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length OF Route 1 DR 0.8240 13.00 7.82 120 0.19005 7 0'-5%Pf 0.847 101 40'-4'% 13.00 4.3 9.140 Sprinkler, 4'-0 Pe -0.170 1 40'-9'% 9.817 T(4'-0) 4'-5%Pv BL 1.0550 26.02 9.55 150 0.136306 28'-1% Pf 4.994 1 40'-9'% 13.02 9.817 Flow(q)from Route 2 8'-6 Pe 4.670 2 30'-0 19.480 4E(2'-0),Tr(0'-6) 36'-7%Pv FR 1.05 5 0 26.02 9.5 5 15 0 0.136306 11-9 Pf 1.874 2 30'-0 19.480 2'-0 Pe 5.094 3 18'-3 26.449 E(2'-0) 13'-9 Pv BL 1.05 5 0 26.02 9.5 5 15 0 0.136306 8'-8 Pf 1.796 3 18'-3 26.449 4'-6 Pe 4 19'-9 28.244 2E(2'-0),Tr(0'-6) 13'-2 Pv BL 1.0550 42.78 15.70 150 0.341915 17'-8'% Pf 8.096 4 19'-9 16.76 28.244 Flow(q)from Route 3 6'-0 Pe 5 19'-9 36.341 3T(2'-0) 23'-8'% Pv FR 1.0550 42.78 15.70 150 0.341915 10'-3 Pf 4.188 5 19'-9 36.341 2'-0 Pe 4.444 6 9'-6 44.973 E(2'-0) 12'-3 Pv BL 1.05 5 0 42.78 15.70 15 0 0.341915 9'-3 Pf 6.070 6 9'-6 44.973 8'-6 Pe 7 9'-6 51.043 3E(2'-0),T(2'-0),Tr(0'-6) 17'-9 Pv RN 1.0550 42.78 15.70 150 0.341915 0'-6 Pf 0.171 7 9'-6 51.043 Pe 0.217 8 9'-0 51.430 0'-6 Pv BL 1.2910 42.78 10.49 150 0.127922 3'-6% Pf 1.222 8 9'-0 51.430 T(3'-0) 6'-0 Pe 9 9'-0 5 2.65 2 T(3'-0) 9'-6% Pv BL 1.2910 42.78 10.49 150 0.127922 7'-11 Pf 1.780 9 9'-0 5 2.65 2 T(3'-0) 6'-0 Pe 10 9'-0 54.433 T(3'-0) 13'-11 Pv BL 1.2910 42.78 10.49 150 0.127922 0'-7% Pf 0.845 10 9'-0 54.433 T(3'-0) 6'-0 Pe 11 9'-0 55.277 T(3'-0) 6'-7% Pv BL 1.2910 42.78 10.49 150 0.127922 7'-1'% Pf 1.680 11 9'-0 55.277 T(3'-0) 6'-0 Pe 12 9'-0 5 6.95 8 T(3'-0) 13'-1'% Pv BL 1.2910 42.78 10.49 150 0.127922 8'-8'% Pf 2.521 12 9'-0 5 6.95 8 T(3'-0) 11'-0 Pe 13 9'-0 59.479 2E(2'-0),Tr(1'-0),T(3'-0) 19'-8'% Pv BL 1.2910 42.78 10.49 150 0.127922 15'-1'% Pf 3.469 13 9'-0 59.479 T(3'-0) 12'-0 Pe -0.217 14 9'-6 62.732 T(3'-0),2E(2'-0),2Tr(1'-0) 27'-1'% Pv BL 1.3800 42.78 9.18 120 0.139711 9'-11'% Pf 3.205 14 9'-6 62.732 13'-0 Pe 4.232 15 -0'-3% 70.168 2f(-0.000),CV(7'-0),T(6'-0) 22'-11% Pv Pump Velocity 15 42.78 70.168 Rating:45.000 @ 40.00 16 Q=42.78 9.18 25.494 Churn Pressure:48.000 _ BL 1.3800 42.78 9.18 120 0.139711 0'-4 Pf 0.045 16 -0'-2% 25.494 Pe 17 -0'-2% 25.539 0'-4 Pv BL 1.0490 42.78 15.88 120 0.5 31207 2'-5%Pf 13.35 8 17 -0'-2% 25.539 2'-0 Pe 18 -0'-2% 38.898 BFP(-11.000),E(2'-0) 4'-5%Pv BL 1.0250 42.78 16.63 150 0.393488 100'-0 Pf 39.349 18 -0'-2% 38.898 Pe 19 -0'-2% 78.246 Water Supply 100'-0 Pv 0.00 Hose Allowance At Source 19 42.78 Route 2 DR 0.8240 13.02 7.83 120 0.190655 0'-5 Pf 0.460 102 40'-5 13.02 4.3 9.171 Sprinkler, 2'-0 Pe -0.149 20 40'-9'% 9.482 E(2'-0) 2'-5 Pv BL 1.0550 13.02 4.78 150 0.037870 8'-4 Pf 0.335 20 40'-9'% 9.482 0'-6 Pe 1 40'-9'% 9.817 Tr(0'-6) 8'-10 Pv Route 3 DR 0.8240 16.76 10.08 120 0.304000 0'-5'/2 Pf 1.354 103 35'-7% 16.76 4.3 15.187 Sprinkler, 4'-0 Pe -0.170 21 36'-0'% 16.372 T(4'-0) 4'-5%Pv ©M.E.P.CAD,Inc. NU AutoSPRINK®12 v12.0.59.0 9/11/2018 12:25:24PM Page 6 Job Number:1 iii Hydraulic Analysis Report Description:Residential Pipe Type Diameter Flow Velocity HWC Friction Loss Length Pressure Downstream Elevation Discharge K-Factor Pt Pn Fittings Eq.Length Summary Upstream Total Length BL 1.0550 16.76 6.15 150 0.060383 39'-1 Pf 3.085 21 36'-0'% 16.372 12'-0 Pe 2.622 22 30'-0 22.079 3E(2'-0),4Tr(0'-6),2T(2'-0) 51'-1 Pv FR 1.0550 16.76 6.15 15 0 0.060383 11'-9 Pf 0.830 22 30'-0 22.079 2'-0 Pe 5.094 23 18'-3 28.003 E(2'-0) 13'-9 Pv BL 1.0550 16.76 6.15 150 0.060383 0'-0 Pf 0.242 23 18'-3 28.003 4'-0 Pe 4 19'-9 28.244 E(2-0),T(2'-0) 4'-0 Pv Equivalent Pipe Lengths of Valves and Fittings(C=120 only) C Value Multiplierll / Actual Inside Diameter \4 87 Value Of C 100 130 140 15 0 l Schedule 40 Steel Pipe Inside Diameter ) =Factor Multiplying Factor 0.713 1.16 1.33 1.51 Pipe Type Legend OM Units Legend Fittings Legend Mi AO Arm-Over Diameter Inch ALV Alarm Valve BL Branch Line Elevation Foot AngV Angle Valve CM Cross Main Flow gpm b Bushing DN Drain Discharge gpm BaIV Ball Valve DR Drop Velocity fps BFP Backflow Preventer DY Dynamic Pressure psi BV Butterfly Valve FM Feed Main Length Foot C Cross Flow Turn 90° FR Feed Riser Friction Loss psi/Foot cplg Coupling MS Miscellaneous HWC Hazen-Williams Constant Cr Cross Run OR Outrigger Pt Total pressure at a point in a pipe CV Check Valve RN Riser Nipple Pn Normal pressure at a point in a pipe DeIV Deluge Valve SP Sprig Pf Pressure loss due to friction between points DPV Dry Pipe Valve ST Stand Pipe E 90°Elbow Pe Pressure due to elevation difference between indicated points UG Underground Pv Velocity pressure at a point in a pipe EE 45°Elbow - Eel 1114°Elbow Ee2 22'04°Elbow f Flow Device fd Flex Drop FDC Fire Department Connection fE 90°FireLock(TM)Elbow fEE 45°FireLock(TM)Elbow flg Flange FN Floating Node fT FireLock(TM)Tee g Gauge GIoV Globe Valve GV Gate Valve Ho Hose Hose Hose HV Hose Valve Hyd Hydrant LtE Long Turn Elbow mecT Mechanical Tee Noz Nozzle P1 Pump In P2 Pump Out PIV Post Indicating Valve PO Pipe Outlet PRV Pressure Reducing Valve PrV Pressure Relief Valve red Reducer/Adapter S Supply sCV Swing Check Valve Spr Sprinkler St Strainer T Tee Flow Turn 90° Tr Tee Run U Union WirF Wirsbo WMV Water Meter Valve Z Cap ©M.E.P.CAD,Inc. NU AutoSPRINK®12 v12.0.59.0 9/11/2018 12:25:24PM Page 7 Bulletin 006 Rev. L June 2018 Reliable Model RFC Series Residential Sprinklers Flat Cover Plate, Concealed Pendent Sprinkler cULus Listed Features v. • cULus Listed as Residential Sprinklers • Push-On cover p late installation • Low water flow requirements ` "+.` t- Product Description i Model RFC Series residential sp rinklersare flat cover p late, concealed pendent sprinklers intended for installation in Model RFC30&RFC30LL Model RFC43&RFC43LL accordance with NFPA 13, NFPA 13R, or NFPA 13D. The sprinklers are cULus Listed as Residential Sp rinklers in ac- cordance with UL 1626. In addition, Model RFCLL Series sp rinklersare cULus Certified for Health Effects to NSF/ANSI standard 61 Annex G (LL). T - If- jr. ( p;[, Model RFC30, RFC43, and RFC49 sprinklers have a 165°F _ r t (74°C) temperature rated fusible-link operating element. -;. - Model RFC58 and RFC76 sp rinklersare offered with either a , 165°F (74°C) or 212°F (100°C) temperature rated fusible-link la operating element. Sp rinklerswith a 165°F (74°C) tempera- ture rating are ordinary temperature classification and are Model RFC49&RFC49LL Model RFC58 listed for use with a 135°F (57°C) temperature rated cover p late.Sprinklers with a 212°F (100°C) temperature rating are intermediate temperature classification and are listed for use �� )111 with a 165°F (74°C)temperature rated cover p late. Model RFC Series sp rinklersare installed with a Model RFC cover p late.Model RFC cover plates may be installed by ei- ther pushing or threading the cover p late into the sprinkler cup.Model RFC30,RFC30LL, RFC43,RFC43LL, RFC49 and RFC49LLsp rinklersallow 1/2" (13 mm)of cover p lateadjust- -_ 6 ment.Model RFC58 and RFC76 sp rinklersallow 3/4"(19 mm) of cover p late adjustment. Model RFC cover plates are avail- able in a variety of finishes as listed in Table H. Model RFC76 Model RFC Cover Plate Table A S rinkler Model Nominal K-Factor Max.Coverage Area Listings& Sprinkler Identification p gpm/psi12(I/min/bar12) ft x ft(mx m) Approvals Number(SIN) RFC30 3.0(43) 14 x 14 (4.3 x 4.3) cULus RA0611 RFC30LL 3.0(43) 14 x 14 (4.3 x 4.3) cULus,LL RA3211 RFC43 4.3(62) 20 x 20(6.1 x 6.1) cULus RA0612 RFC43LL 4.3(62) 20 x 20(6.1 x 6.1) cULus,LL RA3212 RFC49 4.9(71) 20 x 20(6.1 x 6.1) cULus RA0616 RFC49LL 4.9(71) 20 x 20(6.1 x 6.1) cULus,LL RA3216 RFC58 5.8(84) 20 x 20(6.1 x 6.1) cULus RA0613 RFC76 7.6(109) 20 x 20(6.1 x 6.1) cULus RA0618 cULus:cULus Listed to UL1626,Residential Sp rinklersfor Fire Protection Service. LL:cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G(Less than 0.25%Lead content). www.reliablesprinkler.com Model RFC3O&RFC3OLL Residential Sprinklers RFC3O:SINRAO611 RFC3OLL: SINRA3211 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) R Threads:1/2"NP T or ISO 7-1R1/2 "11) Nominal K-Factor:3.0(43 metric) Sensitivity '� Max.Working Pressure: 175 psi(12 bar) Fast-response 8 Min.Spacing:8 ft.(2.4 m) '� . , riy Temperature Rating ".', � s�'9 Material Specifications 165°F(74°C)sprinkler Thermal Sensor:Nickel Alloy Solder Link 135°F(57°C)cover plate j Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate 1_ r„ Yoke:Brass Alloy Model RFC cover plate Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model FC Pins:Stainless Steel , . 2. ` . ` Deflector:Bronze Alloy Listings and Approvals Bottom View • l' `14 17' Cup:Steel cULus Listed to UL 1626 l cULus Certified for Health Effects to NSF/ANSI -= Standard 61 Annex G(RFC30LL only) Model RFC30&RFC3OLLSprinklerComponents and Dimensions Figure 1 2-5/16"(58 mm) Threads Dia. Body Cup _ _ f _ �_ Tower ~5 m _ - 1-3/4"(44 mm)+/-1/4"(6 mm) Fusible Link .�� Nominal face of fitting to ceiling ° ��� %mg* STET ( ) Deflector(retracted) i'v—r v—v 3/16" 5 mm Pin(extended) - Deflector(extended) ;; I 1 Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC30 and RFC3OLL Sprinkler Hydraulic Design Criteria Table B Minimum Flow and Residual Pressure(I) Max.CoverageArea(2) Flow Pressure ft.x ft. gpm psi (mx m) (I/min) (bar) 12 x 12 9 9.0 (3.6 x 3.6) (34) (0.62) 14 x 14 10 11.0 (4.3 x 4.3) (38) (0.76) Notes: 1. For NFPA 13 installations the flow p ersp rinklermust be the greater of:(1)the flow listed in Table B above and(2)the flow required to achieve a minimum design density of 0.1 gp m/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.L �e';ab'� Page 2 of 8 June 2018 www.reliablesprinkler.com Model RFC43& RFC43LL Residential Sprinklers RFC43:SINRAO612 RFC43LL: SINRA3212 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) Threads:1/2"NP Tor ISO 7-1R1/2 Nominal K-Factor:4.3(62 metric) Sensitivity . Max.Working Pressure: 175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) r -,.,f Temperature Rating ,•, .I Material Specifications 165°F(74°C)sprinkler Thermal Sensor:Nickel Alloy Solder Link 135°F(57°C)cover plate Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate 1 Yoke:Brass Alloy Model RFC cover plate • Sealing Assembly:Nickel Alloy with PTFE Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model FC , Pins:Stainless Steel Deflector:Bronze Alloy Listings and Approvals Bottom View . " ; ." Cup:Steel cULus Listed to UL 1626 ' ..',7t4 cULus Certified for Health Effects to NSF/ANSI Standard 61 Annex G(RFC43LL only) Model RFC43&RFC43LL Sprinkler Components and Dimensions Figure 2 2-5/16"(58 mm) Threads Dia. Body Cup �;.l =1 f mw w_ ) Tower Tanirs1-3/4"(44 mm)+/-1/4"(6 mm)Fusible Link ��M Nominal face of fitting to ceiling Deflector(retracted) �a+' `a+ 3/16" 5 mm ) Pin(extended) II II —J; i 11-1-1 Deflector(extended) ,1 ,----. -.,r Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC43&RFC43LLSprinkler Hydraulic Design Criteria TableC Minimum Flow and Residual Pressure(I) Max.Coverage Area(2) Flow Pressure ft.x ft. gpm psi (mx m) (I/min) (bar) 15 x 15 12 7.8 (4.6 x 4.6) (45) (0.54) 16 x 16 13 9.1 (4.9 x 4.9) (49) (0.63) 18 x 18 18 17.5 (5.5 x 5.5) (68) (1.21) 20 x 20 21 23.8 (6.1 x 6.1) (79) (1.64) Notes: 1. For NFPA 13 installations the flow p ersp rinklermust be the greater of:(1)the flow listed in Table C above and(2)the flow required to achieve a minimum design density of 0.1 gp m/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.L �e';ab'� Page 3 of 8 June 2018 www.reliablesprinkler.com Model RFC49&RFC49LL Residential Sprinklers RFC49:SNRAO616 RFC49LL: SNRA3216 Technical Specifications Cover Plate Finishes _s: Style:Flat Concealed Pendent (See Table H) Threads:1/2"NP T or ISO 7-1R1/2 Nominal K-Factor:4.9(71 metric) Sensitivity - . Max.Working Pressure: 175 psi(12 bar) Fast-response �'N' Min.Spacing:8 ft.(2.4 m) Temperature Rating Material Specifications 165°F(74°C)sprinkler f — 1 Thermal Sensor:Nickel Alloy Solder Link 135°F(57°C)cover plate I Sprinkler Body:Brass Alloy Levers:Bronze Alloy Cover Plate Yoke:Brass Alloy Model RFC cover plate Sealing Assembly:Nickel Alloy with PTFE -- Load Screw:Bronze Alloy Sprinkler Wrench Towers:Copper Alloy Model FC y b s Pins:Stainless Steelit Deflector:Bronze Alloy Listings and Approvals Bottom View t '. * ., Cup :Steel cULus Listed to UL 1626 cULus Certified for Health Effects to NSF/ANSI . ✓/' Standard 61 Annex G(RFC49LL only) Model RFC49&RFC49LL Sprinkler Components and Dimensions Figure 3 -..-2-5/16'(58 mm) Threads Dia. Body Cupp = f _ Tower �� 1-3/4"(44 mm)+/-1/4"(6 mm) Fusible Link �4E1 , Nominal face of fitting to ceiling III ��� ����' � �'Deflector(retracted) r r=1+ - \\\\\\\ ro": Iv',/,'',/, r 3/16"(5 mm) Pin(extended) I ' ► Deflector(extended) 11 _ __I_ Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC49&RFC49LL Sprinkler Hydraulic Design Criteria Table D Minimum Flow and Residual Pressure') Max.CoverageArea(2) Flow Pressure ft.x ft. gpm psi (mx m) (I/min) (bar) 16 x 16 13 7.0 (4.9 x 4.9) (49.0) (0.48) 18 x 18 17 12.0 (5.5 x 5.5) (64.3) (0.83) 20 x 20 20 16.7 (6.1 x 6.1) (75.7) (1.15) Notes: 1. For NFPA 13 installations the flow p ersp rinklermust be the greater of:(1)the flow listed in Table D above and(2)the flow required to achieve a minimum design density of 0.1 gp m/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.L ��';��'� Page 4 of 8 June 2018 www.reliablesprinkler.com Model RFC58 Residential Sprinkler SIN RA0613 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) Threads:1/2"NP T or ISO 7-1R1/2 Nominal K-Factor:5.8(84 metric) Sensitivity Max.Working Pressure: 175 psi(12 bar) Fast-response e;;,"--- -Min.Sp acing:8 ft.(2.4 m) Temperature Ratings 0 Material Specifications Ordinary: r i Thermal Sensor:Nickel Alloy Solder Link 165°F(74°C)sprinkler Sprinkler Body:Brass Alloy 135°F(57°C)cover plate Levers:Bronze Alloy Intermediate: -:',7.; `''' Yoke:Brass Alloy 212°F(100°C)sprinkler Sealing Assembly:Nickel Alloy with PTFE 165°F(74°C)cover plate Load Screw:Bronze Alloy Towers:Copper Alloy Cover Plate Pins:Stainless Steel Model RFC Cover P late Deflector:Chrome Plated Bronze Alloy Cup:Steel Sprinkler Wrench Bottom View liP Model FC Listings and Approvals ��—"` cULus Listed Model RFC58 Sprinkler Components and Dimensions Figure 4 2-5/16"(58 mm) Dia. Threads Body Cup /� _ I OWE._=1 ) Tower Fusible Link ���ii� 1 1-7/8"(48 mm)+/-3/8"(9 mm)w Nominal face of fitting to ceiling 11111111--� 11'1 , Deflector(retracted) _—r �' —r _ ,„\\\\ I _ _ 1iiiiiii x3/16"(5 mm) 1,711114.Pin(extended) — Il Deflector(extended) � ,'i' Fi 11 Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC58 Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure) Max.Coverage Area(2) Flow Pressure ft.x ft. gpm psi (mx m) (I/min) (bar) 16 x 16 16 7.6 (4.9 x 4.9) (60.6) (0.53) 18 x 18 18 9.6 (5.5 x 5.5) (68.1) (0.66) 20 x 20 20 11.9 (6.1 x 6.1) (75.7) (0.82) Notes: 1. For NFPA 13 installations the flow p ersp rinklermust be the greater of:(1)the flow listed in Table E above and(2)the flow required to achieve a minimum design density of 0.1 gp m/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.L ��';��'� Page 5 of 8 June 2018 www.reliablesprinkler.com Model RFC76 Residential Sprinkler SIN RA0618 Technical Specifications Cover Plate Finishes Style:Flat Concealed Pendent (See Table H) .®...„ Threads:3/4"NPTor ISO 7-1 R314 /"•�1, Nominal K-Factor:7.6(109 metric) Sensitivity Max.Working Pressure:175 psi(12 bar) Fast-response Min.Spacing:8 ft.(2.4 m) Temperature Ratings _ Material Specifications Ordinary: .. ei _ .--o Thermal Sensor:Nickel Alloy Solder Link 165°F(74°C)sprinkler Sprinkler Body:Brass Alloy 135°F(57°C)cover plate Levers:Bronze Alloy Intermediate: MI Yoke:Brass Alloy 212°F(100°C)sprinkler Sealing Assembly:Nickel Alloy with PTFE 165°F(74°C)cover plate Load Screw:Bronze Alloy Towers:Copper Alloy Cover Plate Pins:Stainless Steel Model RFCCoverPlate Deflector:Bronze Alloy A. a Cup:Steel Sprinkler Wrench Bottom View )- Model FC Listings and Approvals �rrr// cULus Listed Model RFC76 Sprinkler Components and Dimensions Figure 4 f 2-5/16"(58 mm)–IN.- Dia.Dia. Threads Body = Cup i, �, �� Ll l Tower ?='I�'�I'—� 1 __lilWr._–�f II�1�II s —�r/Nr_ 1-7/8 (48 mm)+/-3/8 (9 mm Fusible Link _� _�I�Iw l Nominal face of fitting to ceiling S III _ III Deflector(retracted) _ f ��� \\\\\\\ I _ 1 3/16"(5 mm) Pin(extended) - - -,.I --- ������ /////// Deflector(extended) i H �' 7m��� Model RFC Cover Plate 3-5/16"(84 mm)Dia. Ceiling Model RFC76 Flat Concealed Sprinkler Hydraulic Design Criteria Table E Minimum Flow and Residual Pressure) Max.Coverage Area)2) Flow Pressure ft.x ft. gpm psi (mx m) (I/min) (bar) 16 x 16 21 7.6 (4.9 x 4.9) (79.5) (0.52) 18 x 18 24 9.9 (5.5 x 5.5) (90.8) (0.68) 20 x 20 34 20 (6.1 x 6.1) (128.7) (1.4) Notes: 1. For NFPA 13 installations the flow p ersp rinklermust be the greater of:(1)the flow listed in Table E above and(2)the flow required to achieve a minimum design density of 0.1 gp m/sq ft over the design area of the sprinkler. 2. For coverage area dimensions less than those listed above,use the minimum required flow for the next larger max.coverage area listed. Bulletin 006 Rev.LPage 6 of 8 June 2018 II—enable www.reliablesprinkler.com Cover Plate Finishes(') Table H Standard Finishes Special Application Finishes White Polyester Off White Paint Black Paint Raw Brass Chrome Plated Bright Brass Finished Bronze Black Plated Satin Chrome Stainless Steel Clad(3) Custom Color Paint(2) Notes: 1. Paint or any other coating app liedover the factory finish will void all approvals and warranties. 2. Custom color paint is semi-gloss, unless specified otherwise. 3. Stainless steel clad cover p latesare Typ e316 Stainless Steel on the finished side and C102 Cop p erAllow on the back side. Cover plates are not listed or app rovedas corrosion resistant.Stainless steel clad cover p latesare not available perforated. Installation Dimensions TableJ Recommended Min.to Min.to Max. Cover Plate Cover Plate Max. Face Dropped Deflector Cover Hole Diameter Cover Plate Sprinkler Diameter Adjustment of Fitting to Distance below Model Plate inch in Ceiling inch Ceiling(') Ceiling Temperature Model (mm) (mm) (mm) inch inch Rating (mm) (mm) RFC30, RFC30LL, RFC43, 3-5/16 2-5/8 1/2 1-1/2 to 2 1/2 to 1 135°F RFC43LL, RFC (84) (67) (13) (38 to 51) (13 to 25) (57°C) RFC49, RFC49LL 135°F2 RFC58, RFC 3-5/16 2-5/8 3/4 1-1/2 to 2-1/4 1/4 to 1 (57°C) RFC76 (84) (67) (19) (38 to 57) (6 to 25) or 165°F3 (74°C) Notes: 1. Face of fitting to ceiling dimensions are based on a nominal thread makeup.Verify dimensions based on fitting and thread sealing method p riorto installation.A 1/2"x 1/2"brass nip p leextension(Reliable P/N 6999991900)is available where necessary for rep lacementof existing sprinklers. 2. For use with 165°F(74°C)temperature rated sp rinklerswhere the Maximum Ceiling Temperature does not exceed 100°F(38°C). 3. For use with 212°F(100°C)temperature rated sp rinklerswith the Maximum Ceiling Temperature does not exceed 150°F(66°C). Installation Model RFC series sp rinklersare intended to be installed in ac- Do not exceed the maximum recommended torque.Exceeding cordance with NFPA 13, NFPA 13R, or NFPA 13D, as well as the the maximum recommended torque may cause leakage or im- requirements of app licableauthorities having jurisdiction. Mod- p airment of the sprinkler. Use care when inserting or removing el RFC series sprinklers must not be installed in ceilings with the wrench from the sp rinklerto avoid damage to the sprinkler. p ositive p ressurein the sp ace above.Ensure that the 4 slots in the cup areopenand unobstructed following installation.Model Install the cover plate by hand by pushing the cover plate into RFC series sprinklers are shipped with a protective cap that the cup and turning the cover in the clockwise direction until it should remain on the sp rinkleruntil installed.The p rotectivecap is tight against the ceiling. should be rep laced following installation of the sprinkler and p ermanentlyremoved only when the cover p lateis installed and Ap prication the sp rinklersystem is p laced in service following construction. Model RFC series sp rinklersare intended for installation where Model RFC series sprinklers are installed with the Model FC residential sprinklers are permitted or required by NFPA 13, wrench.The use of any other wrench to installed Model RFC se- NFPA 13R, and NFPA 13D. The sp rinklersare concealed p en- ries sp rinklersis not permitted and may damage the sprinkler. dent residential sprinklers. Temporarily remove the p rotectivecap during installation of the sprinkler. Insert the Model FC wrench over the sp rinkleruntil the Model RFC 30,RFC30LL, RFC43,RFC43LL, RFC49 and RFC49 wrench engages the body.Do not wrench any other p artof the LL sprinklers are available in ordinary temperature classifica- sprinkler/cup assembly.The Model FC wrench is designed to tion for installation where the Maximum Ceiling Temperature be turned with a standard 1/2" square drive.Tighten the sp rin- does not exceed 100°F(38°C). Model RFC58 and RFC76 sp rin- kler into the fitting after app lyinga PTFE based thread sealant klers are available in either ordinary or intermediate temp era- to the sprinkler's threads. Recommended installation torque is ture classification for installation where the Maximum Ceiling 8 to 18 ft-lbs(11 to 24 N-m)for 1/2"thread sp rinklersand 14 to Temperature does not exceed 100°F (38°C) or 150°F (66°C), 20 ft-lbs(19 to 27 N-m)for 3/4"thread sprinklers. respectively. Bulletin 006 Rev.L ��';��'� Page 7 of 8 June 2018 www.reliablesprinkler.com Wrench 'i Model FC Maintenance Guarantee Model RFC series sprinklers should be insp ected and the For the Reliable Automatic Sp rinklerCo., Inc. guarantee,terms, sprinkler system maintained in accordance with NFPA 25. Do and conditions, visit www.reliablesprinkler.com. not clean sp rinklerswith soap and water,ammonia or any other cleaning fluids. Remove dust by gentle vacuuming. Rep lace Patents any sprinkler cover p late assembly which has been painted (other than factory app lied)or damaged in any way.A stock of Model RFC30,RFC30LL, RFC43,RFC43LL, RFC49,RFC49LL, spare sprinklers should be maintained to allow quick rep lace- RFC58,and RFC76 sp rinklersare covered by U.S. Patent No. ment of damaged or op erated sprinklers.Prior to installation, 9,248,327 and U.S. Patent No. 7,275,603. sprinklers should be maintained in the original cartons and packaging until used to minimize the potential for damage to Model RFC30,RFC30LL, RFC43 and RFC43LLsp rinklersare sprinklers that would cause imp rop erop eration or non-op er- additionally covered by U.S. Patent No. 8,776,903. ation. Listings and Approvals Ordering Information Listed by Underwriters Laboratories, Inc. and UL Certified for Sp ecifythe following when ordering. Canada to UL 1626, Residential Sp rinklersfor Fire-protection Service(cULus). Certified by Underwriters Laboratories, Inc. Sprinkler and Underwriters Laboratories of Canada for Health Effects • Model (RFC30,RFC30LL, RFC43,RFC43LL, to NSF/ANSI Standard 61 Annex G (LL)(RFC30LL, RFC43LL, RFC49,RFC49LL, RFC58,RFC76) and RFC49LL only). • Temperature Rating Cover Plate • Model RFC • Temperature Rating • Finish(See Table H) Sprinkler Wrench • Model FC z 0 0 0 0 0 Bulletin 006 Rev.L Page 8 of 8 June 2018 www.reliablesprinkler.com ZURM Model 950XL WILKINS Double Check Valve Assembly Application Designed for installation on water lines to protect against both backsiphonage and backpressure of polluted water into `4 Lai..— the potable water supply.Assembly shall provide protection - ,;�- where a potential health hazard does not exist. Standards Compliance ;-'., (All sizes approved horizontal.Vertical approvals as listed below.) • ASSE® Listed 1015 (vertical 3/4",1 1/2"&2") Options • IAPMO®Listed(vertical 1 1/2", 2") (Suffixes can be combined) • CSA® Listed(vertical 3/4",1 1/2"&2") ❑ - with full port QT ball valves(standard) • AWWA Compliant C510 (vertical 3/4") ❑ L - less ball valves • UL®Classified(less shut-off valves only) ❑ U - with union ball valves • C-UL®Classified(less shut-off valves only) ❑ S - with bronze"Y"type strainer • Approved by the Foundation for Cross Connection Control ❑ TCU - with test cocks"vertical"up and Hydraulic Research at the University of Southern ❑ V - with union swivel elbows(3/4"& 1") California(vertical 3/4") ❑ OSY - with OS&Y gate valves • City of Los Angeles Approved(vertical 1 1/2",2") ❑ FDC - with fire hydrant connection(2"only) • NYC MEA 426-89-M VOL 3 ❑ FT - with integral male 45°flare SAE test fitting ❑ PF - with Z-BiteTM push fit connections*(1/2"-1" only) Materials ❑ PR - with Z-Press TM press fit connections* Main valve body Cast Bronze ASTM B 584 Access covers Cast Bronze ASTM B 584 *Fittings ship in box with valve and must be threaded into Internals Stainless Steel,300 Series valve by hand on site. Elastomers Silicone(FDAapproved) Buna Nitrile(FDAapproved) Polymers NorylTM,NSF Listed Accessories Springs Stainless steel,300 series El Repair kit(rubber only) ❑ Thermal expansion tank(Model XT) ❑ QT-SET Quick Test Fitting Set Features Sizes:3/4", 1", 1 1/2", 2" Maximum working water pressure 175 PSI — E o Maximum working water temperature 180°F ��\ r_ Ohl Hydrostatic test pressure 350 PSI `i�'!C 1!'n![[( hl End connections Threaded ANSI B1.20.1 l�) F `: bo:' D C B • A Dimensions&Weights(do not include p kg.) DIMENSIONS(approximate) WEIGHT MODEL A UNION LESS WITH SIZE A BALL BLESSBALL C D E F G BALL BALL VALVES VALVES VALVES VALVES in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm lbs kg lbs. kg 3/4 20 11 1/4 286 12 1/2 318 7 178 1 1/2 38 3 76 31/2 89 3 76 15 381 5 2.3 7 3.2 1 25 12 1/4 311 13 7/8 353 7 178 1 1/2 38 3 76 3 1/2 89 3 76 17 3/4 451 8 3.6 12 5.4 1 1/2 40 17 1/8 435 19 1/8 486 10 9/16 268 2 51 3 1/2 89 4 1/2 114 4 1/2 114 22 3/4 578 16 7.3 22 10 2 50 18 1/4 460 20 508 10 9/16 268 2 51 3 1/2 89 4 1/2 114 4 1/2 114 25 1/8 638 16 7.3 28 12.7 *Size 1-1/4" Discontinued Zurn Industries,LLC I Wilkins Rev.E 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,Fax 805-238-5766 Date:8/17 In Canada I Zurn Industries Limited Document No.BF-950XL 3544 Nashua Drive,Mississauga,Ontario L4V 1L2 Ph.905-405-8272,Fax 905-405-1292 Product No.Mod eI950XL www.zurn.com Page 1 of 2 Flow Characteristics O Rated Flow(established by approval agencies) MODEL 950XL 3/4",1", 1 1/2" &2" (STANDARD&MET RIC) FLOW RATES(Us) y 15 1.26 2.52 3.8 5.0 15 3.2 6.3 9.5 12.6 15.8 a 0. 3/4"(20mm) 1" ('25"11) I 103 1 1/2"(40mm)cb Co 10 10 ��(50mm) 69 0 w w 5 5 �' 35 E _ co N co W 0 0 20 40 60 80 0 Cl" CC 0 50 100 150 200 250 a FLOW RATES(GPM) Typical Installation Capacity thru Schedule 40 Pipe Local codes shall govern installation requirements.Tobe Pipe size 5 ft/sec 7.5 ft/sec 10 ft/sec 15 ft/sec installed in accordance with the manufacturer's instructions 1/8" 1 1 2 3 and the latest edition of the Uniform Plumbing Code. Unless 1/4" 2 2 3 5 otherwise specified,the assembly shall be mounted at a mini- 3/8" 3 4 6 9 mum of 12" (305mm)and a maximum of 30"(762mm)above 1/2 5 7 9 14 adequate drains with sufficient side clearance for testing and 3/4" 8 12 17 25 maintenance.The installation shall be made so that no part of 1" 13 20 27 40 the unit can be submerged. 1 1/4" 23 35 47 70 1 1/2" 32 48 63 95 2" 52 78 105 167 PROTECTIVE ENCLOSURE ,,Q X90' —— s �:: i o��� 1 12" MIN. 12" MIN 30"MAX. 30"MAX 11. DIRECTION OF FLOW CD. `IN DIRECTION OF FLOW CD' OUT DOOR INSTALLATION INDOOR INSTALLATION Specifications The Double Check Valve Backflow Preventer shall be ASSE® Listed 1015 approved,and supplied with full port ball valves. The main body and access covers shall be bronze(ASTM B 584),the seat rings and all internal polymers shall be NSF®Listed NorylTM and the seat disc elastomers shall be silicone.The first and second checks shall be accessible for maintenance without removing the device from the line.The Double Check Valve Backflow Preventershall be a ZURN WILKINS Model 950XL. Zurn Industries,LLC I Wilkins 1747 Commerce Way,Paso Robles,CA U.S.A.93446 Ph.855-663-9876,Fax 805-238-5766 In Canada I Zurn Industries Limited 3544 Nashua Drive,Mississauga,Ontario L4V 1L2 Ph.905-405-8272,Fax 905-405-1292 www.zurn.com Page 2 of 2 RBVS POTTER UNIVERSAL BALL The Symbol of Protection VALVE SWITCH UL and cUL Listed,FM,CSFM App roved Dimensions: (in cludin gmoun tin g clamps) uo:I:It Large Clamps: 6"L x 5"W x 5.2"H 15,2 cm L x 12,7 cm W x 13,2 cm H •T. 1°1' s 4 Small Clamps: 6"L x 4"W x 5.2"H 15,2 cm L x 10,2 cm W x 13,2 cm H • Weight: With Large Clamps: 13.6 oz.(386,9 g.) With Small Clamps: 11.0 oz.(311,2 g.) e I Enclosure: Non-Corrosive Composite Material Environmental Limitations: • NEMA 4 rated en closure when proper electrical fittings are used.(1P67) • Temperature ran ge:-40°F to 150°F(-40°C to 65°C) • Not for use in hazardous locations Housing Cover Tamper: Activated by housingcover removal US Paten tNo.6,945,509 (Stock No. 1000035 only) Contact Ratings: SPDT Contacts: 10A at 125/250 VAC RBVS Stock No. 1000040(w/o Cover Tamper) 2A at 30 VDC RBVS-T Stock No. 1000035(w/Cover Tamper) SPDT Cover Tamper: 3A at 250 VAC General Installation On Lever Handle(See Fig.2) The Model RBVS is designed to mon itoithe fully open position of a ball valve 1. Select clamps an dclampin gbolts based upon pipe/valve size,see Table 1. in stalledin a sprin klersystem.The un itwill fit on most ball valves in stalledon 2. In sertrubber clamp grippers in to clamps,see Fig.2. back-fl ow-preventers an dalarm trim lin esof dry,alarm,and deluge sprinkler 3. Place one clamp on top of pipe/ball valve n ear the valve han dle an d valves.The switch operates if the ball valve handle is moved from the open insertclampingbolts through it. position.However,the switch does not track the position of the han dle or ball. 4. Place other clamp over clampin gbolts from ben eaththe in stallation an d When the ball valve han dleis in the open position,a spring-loaded switch button thread hex n utson to the clampin gbolts,but do n otfully tighten,(be sure will con tactthe valve handle.When the handleis moved from the open position, hex nuts seat properly in clamp hex recesses).(NOTE:Some in stallation s this switch button exten ds to the tripped position,an d the RBVS con tactschan ge may require one of the moun tin gbolts to be in sertedfrom the bottom of state,thereby openingor closing a circuit.A cover tamper switch is available and the brackets andthen trimmed to allow the extension bracket to clear. is activated by the removal of the RBVS housin gcover.If an attempt is made See Fig.4) to remove the RBVS by the removal of the moun tin gbrackets,the un itwill be 5. Attach extension bracket(if necessary to use for positioning)to top clamp set in tothe tripped mode by this action. using'/4-20 X'/4"Hex bolt an dwasher,but don otfully tighten. The RBVS can be moun ted to the hex portion of the ball valve or back-flow- 6. Attach"L"bracket(RBVS switch en closure is loosely attached to"L" preven teror to the adjoin in gpipe via two clamps.The RBVS is shipped with two bracket)to exten sion bracket usin g'/4-20 X 3/4"Hex bolt an dwasher,but sets of mountingclamps to accommodate various pipe andvalve sizes,refer to do surebly tighten. Table 1.An"L"shaped andoffset bracket for moun tin gthe switch enclosure and 7. Be sure ball valve is in the fully open position. an exten sionbracket add to the moun tin gl�exibility of the RBVS.See"Typical 8. Slide loosely assembled RBVS switch en closura position that permits the switch button to con tactthe valve han dle approximately 1" from its Moun tin gDiagram"an d"In stallatiomn dOperation"on followin gpage. in sideen d.See Fig. 1 for approximate location.Cut an dremove the plastic Testing coating from the ball valve handle to allow the RBVS switch button to The RBVS and its associated protective monitoring system should be tested con tact(and be activated by)the metal of the han dle. in accordan cewith applicable NFPA codes an d standards an d/orthe authority 9. Tighten clampin gscrews altern ately to an even tual30 in-lbs.(minimum) havin gjurisdiction(manufacturer recommen dsquarterly or more frequently). of torque. 10. Main tainposition of switch en closure over valve han dle an d secure bolt Fig.1 Internal Components that holds the exten sion bracket to the clamping assembly.It may be NORMALLY OPEN necessary to close valve to access this bolt. 11. Position"L"bracket so that it con tactsthe back edge of the valve han dle,an d NORMALLY CLOSED �, secure its bolt.It may be n ecessaryto close valve to access this bolt. COMMON ��rIM.:� • 12. With the actuator fullyretracted,position RBVS switch enclosure to kkb 1M.'` con tact the valve handle squarely,see Fig. 1. ""� �' 13. With RBVS switch en closure held squarely in contactwith valve handle, STRAIN RELIEF q Y 11111,50404 � � ® SWITCH BUTTON securely tighten the two tamper resistant screws on the backside of the IIrBLACKCOVER RED - N.O. `• ••• ,L' '�`I0 LOCATION TAMPER GRED — N.C, • �✓ ON HANDLE en closure. WHITE - COMM 14. Close andopen the valve to verify operation.The actuator should easily retract when the valve han dle is in the open position. 15. Fully open the valve. MOUNT SO 16. Remove the cover andwire main switch andtam tamper switch if applicable. SWITCH BUTTON \�� p pp IS APPROX. 1" FROM PLASTIC COATINGO REMOVED FROM Carefully route tamper switch wires through strain relief channefin switch HANDLE INSIDE END BALL VALVE HANDLE en closure Fully seat the wires in tothe bottom of the chann el See Fig.1. CONTACTIN CTH BUTTON 17. Replace RBVS switch en closure over an dsecurel tightencover screw. DWG #1086-1 AREA P Y g Potter Electric Sign alCompany,LLC•2081 Craig Road,St.Louis,MO,63146-4161 •Phone:800-325-3936/Canada 888-882-1833•www.pottersignal.com PRINTED IN USA MFG.#5401086-REV U PAGE 1 OF 2 5/08 P POTTER RBVS UNIVERSAL BALL ® The Symbol of Protection VALVE SWITCH Fig.2 Typical Mounting Diagram Table 1 Clamp Sizing 1: LENGTH Pipe Valve/Size Clamp Clamping Bolts SWITCH 1/2"to 3/4"(12,5 to 19mm) Small 10-32 x 2 1/2 --11 ENCLOSURE '.� 1"to 2"(25 to 50mm) Large 1/4-20 x 4" NIil "L" BRACKET ,7 it HEIGHT Switch Terminal Connections,Clamping Plate Terminal -=fipig r EXT, BRACKET 0 5 2"�a� '�' 7.7. 1ion ` (IF NECESSARY) —` ' �'o or r, 9 ��� A CAUTION O �� V�\\�0���� Anuninsulatedseptionofsin glecon ductor CLAMPS should notbeloo edaroundtheterminal �r� ■�.-s17%-.. od andserve as two se crate con nections,The pi 17 CLAMP . ro�too�' DWOO 923-3 wire must be severed,thereby providing GRIPPERS supervision of the con n ectionin the even t WIDTH 4" (SMALL) f that the wire becomes dislodged from DWG #1086-2 5" (LARGE) undertheterminal. Typical Electrical Connections LOCAL CIRCUIT TRANSFORMER OR BATTERY POWER STYLE D (CLASS A) SUPERVISED LOOP STYLE B (CLASS B) SUPERVISED CIRCUIT N.C. SIGNALING COM, COM, TO N,C, N,O, DEVICE N.C. N,C, UNIN,O. N.O. CONTTROL COM,• NO END-OF-LINE RESISTOR DWG. #1086-4 Tamper Switch Connections Fig.3 COVER TAMPER & RBVS CONNECTED COVER TAMPER & RBVS WIRED SWITCH ENCLOSURE TO THE SAME ZONE ON THE FACP TO SEPERATE ZONES COVER ` CM N•O•COM. D- TAMPER , OFFSET BRACKET COM, N.O. COM. •, / --°."'J FACP COVER EOLR N.C, TAMPER FACP EOLR FAC EOLR I �� N.O. S �y TaIDWG.x,086-5 NIS`Installation on Tee Handle(See Fig.3) '��= �'� `v 'L"BRACKET 1. Select clamps an dclampingbolts based upon pipe/valve size,see Table 1. ��f„�, GP -1 �I 2. In sertrubber clamp grippers into clamps,See Fig.3. 401,...0 V i„ 3. Place one clamp on top of pipe/ball valve n earthe valve han dlean d "MPS I in sert clampin gbolts through it. L - 4. Place other clamp over clampin gbolts from ben eaththe in stallation CLAMP GRIPPERS DWG X1086-3 an dthread hex n utson to the clampin gbolts,but do not fully tighten, (be sure hex nuts seat properly in clamp hex recesses). 5. Loosely attach "L” bracket to the "offset" bracket and "offset" bracket to the RBVS housing. Fig.4 6. Be sure ball valve is in the fully open position. it 7. Slide loosely assembled RBVS switch en closure to a position that RBVS ®� permits the switch button to con tactthe valve han dleapproximately l 1/2"from the end of the han dle.Cut an dremove the plastic coating I J I from the ball valve handle to allow the RBVS switch button to contact (an dbe activated by)the metal of the handle. I— (minimum) 0 8. Tighten clampingscrews alternately an d'/-20X 3/4"bolt to 30 in-lbs. of torque. SOME INSTALLATIONS MAY 9. With the valve handle fully open,slide the RBVS housing down CAUSE INTERFERENCE BETWEENMOUNTINGBOLTAND �_ _ untilthe switch operatesplus 1/8 inch.Tighten the screws holding1 p g OFFSET BRACKET.INSTALL BOLT A the RBVS to the"offset"bracket. FROM BOTTOM ANDTRIMAS��■ini ■ PIPE 10.Remove the RBVS switch en closure cover. NEEDED TO CORRECT.11. Close and open the valve to verify operation.The actuator should easily retract up when the valve handle is in the open position. 12.Fully open the valve. \/ 13.Wire main switch an dtamper switch(if applicable).Carefully route Irl tamper switch wires through strain relief chan n eln switch en closure. Dwca Ioa 6-6 Fully seat the wires into the bottom of the channel.See Fig. 1. 14. Replace RBVS switch en closurecover an dsecurely tighten cover screw. PRINTED IN USA MFG.#5401086-REV U PAGE 2 OF 2 5/08 NI BCO® wwwonbconcom AHEAD OF TH E FLOW ' 06/21/05 Class 125 Bronze Check Valves Dezincification Horizontal Swing• Regrinding Type • Y-Pattern • Resistant Renewable Seat and Disc 125 PSI/8.6 Bar Saturated Steam to 353°F/178°C - 200 PSI/13.8 Bar Non-Shock Cold Working Pressure CONFORMS TO MSS SP-80 MATERIALLIST T-413 PART SPECIFICATION Threaded 1. Bonnet Bronze ASTM B 62 2. Body Bronze ASTM B62 3. Hinge Pin Bronze ASTMB 140 Alloy C31400 or o B 134 Alloy C23000 0 4. Disc Hanger Bronze ASTMB 62 or © �� pd �ti 304 Stainless Steel Ye thru 3/4"sizes 4 ` � 5. Hanger Nut Bronze ASTMB 16 0 z►wa �dl 6. Disc Holder Bronze ASTMB 62 z' ���� 7. Seat Disc Water,Oil or Gas(Buna-N)(W) 1111 it `,`� Illlillllll B Steam(PTFE)(Y) Bronze ASTMB 62(B) Viton 8. Seat Disc Nut Bronze ASTMB16 or B 62 A 9. Hinge Pin Plug Bronze ASTMB 140 Alloy C32000(not shown) T-413-B *10. Seat Disc Washer ASTMB 98 Alloy C6550 0 NPTx NPT or ASTMB 103(not shown) *Sizes 3/4",1",1W/a",and we only. o AOV1 44 k rose DIMENSIONS-WEIGHTS-QUANTITIES - Q d►` •,, Dimensions 0 �IIIIiIIIII S43- ��II1III�I,I Size A B Master i In. mm. In. mm. In. mm. Lbs. Kg. Ctn.Qty. 1/4 8 2.13 54 1.63 41 0.50 0.23 50 I�Ii) 11111!11!11 3/8 10 2.13 54 1.63 41 0.47 0.22 50 N1010420.1 '/2 15 2.44 62 1.69 43 0.55 0.25 50 T-413-Y 3/4 20 2.94 75 1.88 48 0.90 0.41 50 NPT x NPT 1 25 3.56 90 2.31 59 1.46 0.66 30 1 Y4 32 4.19 106 2.69 68 2.17 0.99 20 1'/2 40 4.50 114 2.94 75 2.95 1.34 10 2 50 5.25 133 3.94 100 4.79 2.17 10 2Yz* 65 8.00 203 5.06 129 11.48 5.21 5 3* 80 9.25 235 6.25 159 17.53 7.96 4 NIBCO check valves may be installed in both horizontal and Ordering:T-413 normally furnished with Bronze Disc(T-413-B). vertical lines with upward flow or in any intermediate position. Available with PTFE Steam Disc(T-413-Y)or CWP Disc They will operate satisfactorily in a declining plane(no more (T-413-W)or 300°F67PSI steam Viton Disc(T-413-V). than 15°). *-Class 150(433)furnished for these sizes. Warning-Do Not Use For Reciprocating Air Compressor Service. ® NIBCO INC.WORLDHEADQUARTERS•1516 MIDDLEBURYST.•ELKHART,IN 46516-4740•USA•PH:1.80 0.234.0 227 TECHSERVICES PH:1.888,446.4226• FAX:1.888.336.4226•INTERNATIONALOFFICE PH:+1.574.295.3221•FAX:+1,574.295.3455 www.nibco.com SYSTEM �$ SENSOR`°' T-Tap WaterflowDetectors System SensorT-Tap Waterflow Detectors are designed forprimarysignalingin residential systemsand branch • line signalingin largersystems. Features Both the WFDTretard model and the WFDTNRnon-retard model fit •Sealed retard mechanism(Model WFDT) any tee that has a 1"NPT branch,including: 1",11/4",1'1"and 2"NPT threaded ferrous and brass tees;1",11/4",11"and 2"cop p ersweat •Visual switch activation(Model WFDT) tees;Tyco,Spears,Victaulic and NIBO brand 1"CPVCtees;and 11/" •Twelvedifferent flexible p lasticp addles p olybutylenetees. •Vertical or horizontal mount Design.The design of the WFDTand WFDTNRmakes them easy •Durable,tamper-resistant enclosure to install and simp leto maintain.Either can be mounted in the •Dual SPDTswitches in durable terminal block vertical or horizontal position.Twoconduit op eningsp ermiteasy •Sizes marked on flexible p lasticp addles attachment to the local alarm system.The retard mechanism(Model WFDTonly)and switch assemblies are field-replaceable. •100 percentsynchronization activates both alarm paneland local bell •Accommodates up to 12 AWG wire Features Twelve different flexible p lasticp addles fit 1",11/4",111`and 2"tees.Sizes are marked clearly on the paddles for ease of installation. Plastic paddles slip over the actuating lever and are securely fastened with one screw.The handy dep thgauge ensures the proper installation dep thand clearance of the detector to the tee. Construction.The W FDTand WFDTNRinclude a durable,tamp er- resistant enclosure and rugged switch assembly.The robust covers comp letelyenclose the electrical comp onentsto keep out dust and dirt.Imp rovedself-guiding security screwsand removal tools make the detectors resistant to tamp eringand simp lifyfield maintenance. Dual SPDTswitches are enclosed in a durable terminal block for added strength. Agency Listings U °i N � MEA LISTED approved APP® 5739 7770-1653:114 :3 F T-TapWaterflowDetectorSpecifications Architectural/Engineering Specifications Model shall be a WFDTorWFDTNRas manufactured by System Sensor.T-tapwaterflow detectors shall be installed on a tee that has a 1"NPT branch including: 1",11/4", "or 2"threaded ferrous or brass tee;1-2"cop p eisweattees;Tyco,Sp ears,Victaulic®and NIBCO brand 1"CPVC tees;or 11/2"polybutylene tee as designated on the drawings and/or as sp ecifiedherein.Detectors shall mount on any clear p ip ES anof the appropriate size,eithera vertical or horizontal run at least 6"from any fittings or valvesthat may change waterdirection,flow rate,or pip ediameteror no closerthan 24"from a valve or drain.Detectors shall have a sensitivityin the range of 4 to 10 gallons p erminuteand a static pressure rating of 250 p sae retard t-tapdetectorshall be a sealed mechanical p neumaticunit with visual indication of actuation.Theactuation mechanism shall include a polyethylene vane inserted through the teefitting and connected by a mechanical linkage to the delay mechanism.The non-retard t-tap detectorshall respond with no time delay to waterflow in the sp ecifieddirection and range.Outputs shall consist of dual SPDTswitches(Form C contacts).Twoconduit entrances(one of which is a knockouttyp e)forstandard fittings of commonly used electrical conduit shall be provided on thedetectorsA grounding provision is p rovidedAll detectors shall be listed by Underwriters Laboratories forindoor or outdoor use. Physical/Operating Specifications Static Pressure Rating 250 PSI OperatingTemperature Range 32°F to 120°F(0°C to 49°C) Maximum Surge 18 FPS Enclosure Rating UL indoor/outdoorrated TriggeringThreshold 4-10 GPM Coy erTamperSwitch UL models:op tionalP/N 546-7000 Bandwidth(Flow Rate) ULC/Canadian models:factoryinstalled Ov erallDimensions, WFDT:4.5"H x 3.75`W x 6.7"L Sery iceUse AutomaticSprinkler:NFPA 13 Installed (11.4cm H x 9.5cmW x 17cm L) One orTwoFamily Dwelling:NFPA 13D WFDTNR:3.75"H x 3.25"W x 4.25"L Residential Occupancies up to 4 Stories:NFPA 13R (9.5cm H x 8.2cmW x 10.8cm L) National FireAlarm Code:NFPA 72 Contact Ratings Two sets of SP DT(Form C) Shipping Weight WFDT:2.6 lbs.(1.2 kg.) 10.0 A @ 125/250 VAC WFDTNR:1.5 lbs.(0.7 kg.) 2.5A@24VDC CompatibleTee Threaded ferrous and brass tees,copper Warranty 3 years Fittings sweattees,CPVC tees,and polybutylene tees Conduit Entrances Twoopeningsfor'h"conduit. U.S.PatentNumbers 5,213,205 Electrical ConnectionsforWFDT Delay AdjustmentDial SSM24-X NOTE:COMMON AND B-NO DELAY UL-LISTED CONNECTIONS WILL CLOSE ADJUSTMENT COMPATIBLE SSV120-X WHEN VANE IS DEFLECTED,I.E., DIAL 7.ON DIAL IS App WHEN WATER IS NG.DUAL CP OWER PANEL APPLICATIONSWIT EP ERM BE CIOMBINED '�J�pV" DE1-P'Y VN SF'04/174„.%N MS' 24VDC OR ON A SINGLE DETECTOR. 0 120VAC - S I CONTACT RATINGS INITIATING+-SUGGESTED EOL 125/250 VAC 10 AMP S O LOOP RESISTOR 24VDC 2.5 AMP S SCHEMATIC OF c i OOO/ ' INDIVIDUAL c°M UO / 4) g dill SWITCH IN +U :Tj }I CONDITIONFLOW — o .T. 45 �.. A BiiO BfAI A • b SHOW WIREAS , �4�•SIIITOi 1 swag 2 `V. SHOWN FOR n.Na 15 SUP BREAK NOF AS rimi 3• cwrw CONNECTION.DO .7J•Y�•rd• NI NIIIIr ��• NOT ALLOW Iml:r.l I MOM EIMS _ STRIPPED WIRE 1 1 O• `°) ( M i(j) LEADS TO EXTEND J L NOTE:RETARD TIME MAY EXCEED 90 SECONDS.ADJUST BEYOND SWITCH AND VERIFY THAT TIME DOES NOT EXCEED 90 SECONDS. HOUSING.DO NOT NUMBER ON DIAL IS APPROXIMATE TIME DELAY IN 0• —,O HOUSING.OP S. SECONDS W ITHpN ACCURACY OF+I-SO%. Ordering Information ULC Model Description WFDT WFDTA Waterflow Detector,Fits 1",11/4",11 ",2"ferrous and brass threaded tees;1",11/",11/",2"cop p esweat tees;1"CPVCtees;and 11/2"polybutylene tees WFDTNR — Waterflow Detector,non-retard,fits same tees as Model WFDT Accessories Description A77-01-02 Rep lacementterminal block forWFDT A77-01-08 Rep lacementterminal block forWFDTNR A3008-00 Rep lacementetard mechanism PRK9 Rep lacementp addlekit-12 p addlesforWFDTand WFDTNR(seeWFDTforsizes) 546-7000 Covertamp erswitch kitforWFDT S07-66-02 Replacement tamp erscrews forcovers ofWFDTWFDTNR WFDW Replacement tamper-proof wrench forcover of WFDT,WFDTNR WFDN4 NEMA-4gasketkit C58-164-01 Rep lacemenenetal cover C58-195-01 Rep lacementp lasticcover(WFDTNR) *--Th_ Spears°is a registeredtrademark of the Sp earsManufacturing Comp anyVIctaulic°is a registered trademark oftheVictaulic Comp anyof America. SYSTEM 02010 System Sensor. 3825 Ohio Avenue•St.Charles,IL 60174 Pro ductspecificatiooNJbjecttochangewithoutnotice.Visitsystemsensor.com for ), SENSOR® Phone:800-SENSOR2•Fax:630-377-6495 curren5Jroductnformation,includingthelatestversionofthisdatasheet. A05-0195-014•7/10•#2450 EPS10-1 AND EPS10-2 *--_ SYSTEM Alarm Pressure Switches SENSOR® Models Available EPS10-1 One SPDT Switch EPS10 Series EPS10-2 Two SPDT Switches - - EPSA10-1 ULC/Canadian Version ._ . EPSA10-2 ULC/Canadian Version Replacement Parts ., Pressure Adjustment Wheel S07-66-02 Replacement Cover Screws = • WFDW Replacement Cover Wrench 546-8000 Cover Tamper Switch •41 'Lb' '. R • Product Overview Sensitivity adjustment wheel, System Sensor EPS10 Series switches are designed for use in wet, dry,deluge,and pre- no tools required action automatic sprinkler systems to indicate a discharge from a sprinkler.The EPS10-1 has a single SPDT switch while the EPS10-2 model contains two SPDT switches. Reinforced diaphram resists pressure spikes The EPS10 Series features field adjustable pressure sensitivity to provide an alarm Two conduit entrances provided responsebetween 4 and 20 psi.It is factory set to respond at 4—8 psi on rising pressure. The pressure adjustment wheel requires no special tools and does not NEMA 4 rated affect switch syn chron izationon the EPS 10-2. Engineering Specifications EPS10-1 (SPDT), EPS10-2 (2/SPDT) Model shall be an EPS10-1 or EPS10-2 pressure type waterflow switch as manufac- tured by System Sen sorof St.Charles,IL.They shall be installedon the sprinkler system with con n ection as shown on the drawings and/or as specified herein. Pressure switches shall be of the bellows-activated type. Switches shall have a maximum service pressure rating of 250 psi and shall be fac- tory adjusted to operate at a pressure of 4—8 psi.There shall be one(1) or two (2) SPDT contacts rated at 10.0 Amp @ 125/250 VAC and 2.5 Amp @ 6/12/24 VDC. The contractor shall furnish and in stall,where in dicated on the plan s,pressure switches according to appropriate NFPA standards.Switches shall be provided with a '/" NPT male pressure connection to be connectedto the alarm check valve of a "wet" sprinkler system, into the in termediate chamber of a"dry" system, or to a pre-action or deluge valve.They shall be activated by any flow of water equal to or in excess of the discharge from one sprinkler head. Switches shall provide 1 knock- out type and 1 open hole for ''/�" conduit fittin g attachment and a ground screw provision for electrical grounding. The switch en closure shall be weatherproof and carry a UL 4x/NEMA 4 rating when used with proper electrical fittingsand conduit.The cover shall incorporate MEATl�c UL tamper-resistant screws. approved ® ®' ® The unit shall be listed by Underwriters Laboratories,Inc.and approved by Factory sr .. " LISTED Mutual. Specifications Maximum Operating Pressure Switch Contact Ratings Enclosure 250 psi EPS10-1: One set SPDT (Form C) Rated UL 4x, NEMA 4 for indoor or outdoor use EPS10-2:Two sets SPDT(Form C) Differential10.0 A, Shipping Weight '/z HP @ 125/250 VAC Approximately 3 psi throughout range 2.5 A @ 6/12/24 VDC 1.2 lbs. (.54 Kg) Maximum Adjustment Pressure Range Dimensions Ser vice Use 4 to 20 psi5.12" H x 3.325"W x 4.250" L Automatic Sprinkler: NFPA 13 (13.0 cm x 8.4 cm x 10.8 cm) One or Two Family Dwelling: NFPA 13D Factory Setting Residential Occupancies up to 4 Stories: NFPA 13R Operates at rising pressure 4 to 8 psi Operating Temperature Range: National Fire Alarm Code: NFPA 72 Pressure Connection Indoor or outdoor use '/z" NPT male glass reinforced nylon -40°F to 160°F(-40°C to 71°C) Warranty 3 years Cover Tamper Switch UL Models: Optional P/N 546-8000 ULC Models: Factory Installed Presure Switch Basic Dimensons Electrical Connections for EPS1O-1 and EPS1O-2 4-1/4" MODEL EPS10-2 MODEL EPS10-1 GROUND .y SWITCHES AT 0 PSI DD j SWITCH AT 0 PSI B X B SCREW �, B COM X COM X I8 I. 0(GREEN SWITCH#2,\ HEX COM X A SW1 A SW2 N. __,igh► # ADJUSTMENT SWITCHES AT 4-8 PSI(HIGH TRIP PT.) i SCREW SWITCH AT 4-8 PSI(HIGH TRIP PT.) B B v .. /G 9, 2 JAN '•IInU IIO_'I a COM U COM v. X COM X 5-1/8" A X A SW1 A SW2 1.1.. MAIN ADJUSTMENT SWITCH 1 BOTH SWITCHES ACTIVATE SIMULTANEOUSLY LOCKING SCREW 1/2"NPT Typical Sprinkler Applications WIRE TO ALARM TO WIRE TO WIRE TO EPS10 INDICATING CIRCUIT SPRINKLER EPS10 ALARM ALARM OF FIRE ALARM SYSTEM INDICATING EPS10 INDICATING A • CONTROL PANELTO • OF FIRCIRCUIT E CIRCUIT SPRINKLER • OF FIRE ALARM TO ALARM WATER ALARM SPRINKLER CHECK MOTOR ALARM SYSTEM CONTROL PANEL CHECK SYSTEM WATER VALVE GONG CONTROL CHECK VALVEA MOTOR A all PANEL DRY VALVE WATER RMII ENG PIPE ME MOTOR RETARD RETARD VALVE GONG WATER LOCAL ALARM - WATER LOCAL ALARM WATER LOCAL ALARM OS&Y� BY-PASS SHUT OFF OS&Y: BY-PASS SHUT OFF OS&Y V BY-PASS SHUT OFF VALVE VALVE VALVE VALVE VALVE VALVE VALVE A VALVE VALVE WET SYSTEM WET SYSTEM DRY SYSTEM Ordering Information Replacement Parts Model Description Model I Description EPS10-1 Alarm Waterflow Pressure Switch,One SPDT,4-20 PSI S07-66-02 Replacement Tamper Screws for Cover of EPS EPS10-2 Alarm Water flow Pressure Switch, Two SPDT, 4-20 PSI WFDW Replacement Tamper Proof Wrench for Cover of EPS EPSA 10-1 ULC/Canadian Version 546-8000 Cover Tamper Switch for EPS Series EPSA10-2 ULC/Canadian Version System Sensor Sales and Service System Sensor Headquarters System Sensor in Canada System Sensor in China System Sensor in the Far East 3825 Ohio Avenue Ph:905.812.0767 Ph:+86.29.524.6253 Ph:+852.21919003 St.Charles,IL 60174 Fx:905.812.0771 Fx:+86.29.524.6259 Fx:+852.27366580 Ph:800-SENSOR2 Fx:630/377-6495 System Sensor in Europe System Sensor in Singapore System Sensor in Australia Documents On Demand: Ph:+44.1403.276500 Ph:+65.273.2230 Ph:+613.54.281.142 1-800-736-7672 x3 Fx:+44.1403.276501 Fx:+65.273.2610 Fx:+613.54.281.172 Web:www.systemsensor.com ©1999 System Sensor.The company reserves the right to change product specifications without notice. A05-176-06.7/99(5K)•#491 EPS40-1 AND EPS40-2 f SYSTEM Supervisory �� SENSOR® Pressure Switches Models Available EPS40-1 Low Pressure EPS40 Series Supervisory Switch - - EPS40-2 High/Low Pressure ._ . Supervisory Switches - EPSA40-1 ULC/Canadian Version EPSA40-2 ULC/Canadian Version Pressure Adjustment Wheel Replacement PartsNZ — - '. ' , S07-66-XX Replacement Cover Screws � - y WFDW Replacement Cover Wrench '1"N. I. 546-8000 Cover Tamper Switch ., • - - • Product Overview Sensitivity adjustment wheel, System Sensor EPS40 Series switches are designed for use in dry pipe systems or pres- no special tools required sure tanks and water pressure supplies of automatic water control valves.The EPS40-1 has a single SPDT switch while the EPS40-2 model contains two SPDT switches. Reinforced diaphram resists pressure spikes The EPS40 Series features field adjustable pressure sensitivity to provide an alarm responsebetween 10 and 100 psi.All models are factory set for use in a nominal40 Two conduit entrances provided psi system. The EPS40-1 is factory set to respond at 30 psi at decreasingpressure N EM A 4 rated while the EPS40-2 is factory set to respon d at 50 psi on risin gpressure and 30 psi at decreasingpressure. The pressure adjustment wheel requires no special tools and does not affect switch syn chron izationon the EPS40-2. Engineering Specifications EPS40-1 (SPDT), EPS40-2 (2/SPDT) Model shall be an EPS40-1 or EPS40-2 pressure type waterflow switch as manufac- tured by System Sen sorof St.Charles,IL.They shall be in stalledon the sprinkler system with connection as shown on the drawings and/or as specified herein. Pressure switches shall be of the bellows-activated type. Switches shall have a maximum service pressure rating of 250 psi and shall be adjustable from 10 - 100 psi.There shall be one(1)or two (2) SPDT contacts rated at 10.0 Amp @ 125/250 VAC and 2.5 Amp @ 6/12/24 VDC. The contractor shall furnish and in stall,where in dicated on the plan s,pressure switches accordin g to appropriate NFPA stan dards.Switches shall be provided with a ''/2" NPT male pressure connection to be con n ectedin to the air supply lineon the system side of any shut-off valve.Switches shall provide 1 knockout type and 1 open hole for '/2" conduit fittin g attachment and a ground screw provision for elec- trical groun ding. The switch en closure shall be weatherproof and carry a UL 4x/NEMA 4 ratin g when used with proper electrical fittin gs an d conduit.The cover shall in corporate tamper-resistant screws. ® 1? le ,;Ir;=-�.c The unit shall be listed by Underwriters Laboratories,Inc.,the California State Fire ME/1 Marshal,MEA, and approved by Factory Mutual. vl A approved LISTED Specifications Maximum Operating Pressure Switch Contact Ratings Enclosure 250 psi EPS40-1: One set SPDT (Form C) Rated UL 4x, NEMA 4 for indoor or outdoor use EPS40-2:Two sets SPDT(Form C) Differential 10.0 A, Shipping Weight '/z HP @ 125/250 VAC Approximately 3 psi @ 10 psi, 6 psi @ 100 psi 2.5 A @ 6/12/24 VDC 1.2 lbs. (.54 Kg) Maximum Adjustment Pressure Range Dimensions Ser vice Use 10 to 100 psi 5.12" H x 3.325"W x 4.250" L Automatic Sprinkler: NFPA 13 (13.0 cm x 8.4 cm x 10.8 cm) One or Two Family Dwelling: NFPA 13D Factory Setting Residential Occupancies up to 4 Stories: NFPA 13R EPS40-1 operates at decreasing pressure at 30 psi Operating Temperature Range: National Fire Alarm Code: NFPA 72 EPS40-2 operates at increasing pressure at 50 psi Indoor or outdoor use and decreasing pressure at 30 psi -40°F to 160°F(-40°C to 71°C) Warranty 3 years Pressure Connection Cover Tamper Switch '/s" NPT male UL Models: Optional P/N 546-8000 ULC Models: Factory Installed Presure Switch Basic Dimensons Electrical Connections for EPS40-1 and EPS40-2 4-1/4" MODELS EPS40.1 MODELS EPS40.2 AGROUND j SCREW 41 1 SWITCH AT40 P.S.I.(NORMAL) SWITCHES AT 30 P.S.I.(LOW TRIP PT.) 0(GREEN SWITCH#2 I. 6 HEX B� COM X COM X I I \ ADJUSTMENT CoA X A A m 0 SCREW SW1 SW2 ^ �� =�� �'/� SWITCH AT 30 P.S.I.(LOW TRIP PT.) SWITCHES AT 40 P.S.I.(NORMAL) 9, 2 J�Nluuli l.IInU l d B 5.1/8.. ��� COM X B B LOCKING 1.1.. WHELMAIN DJUSTMENT A COA SW1X COA SW2XSCREW SWITCH 1 SWITCHES AT 50 P.S.I.(HIGH TRIP PT.) 1/2"NPT B-.7. B-.7 COMAX CO X SW1 SW2 Typical Sprinkler Applications WIRE TO SUPERVISORY WIRE TO ALARM CIRCUIT OF FIRE ALARM INDICATING CIRCUIT EPS40 CONTROL PANEL EPS10 OF FIRE ALARM CONTROL PANEL T TSYO • SPRINKLER SYSTEM INSTALL CHECK CHECK • BLEEDER DRY VALVE VALVE ♦ VALVE FOR PIPE WATER TESTING VALVE MOTOR ►� GONG AIR LINE SHUT-OFF 0.11 ► VALVE WATER LOCAL ALARM OS&Y V BY-PASS SHUT OFF VALVE ♦ TEST VALVE VALVE DRY SYSTEM Ordering Information Replacement Parts Model Description Model I Description EPS40-1 Low Pressure Supervisory Switch,One SPDT, 10-100 PSI S07-66-XX Replacement Tamper Screws for Cover of EPS EPS40-2 High/Low Pressure Supervisory Switch,Two SPDT,10-100 PSI WFDW Replacement Tamper Proof Wrench for Cover of EPS EPSA40-1 ULC/Canadian Version 546-8000 Cover Tamper Switch for EPS Series EPSA40-2 ULC/Canadian Version System Sensor Sales and Service System Sensor Headquarters System Sensor in Canada System Sensor in China System Sensor in the Far East 3825 Ohio Avenue Ph:905.812.0767 Ph:+86.29.524.6253 Ph:+852.21919003 St.Charles,IL 60174 Fx:905.812.0771 Fx:+86.29.524.6259 Fx:+852.27366580 Ph:800-SENSOR2 Fx:630/377-6495 System Sensor in Europe System Sensor in Singapore System Sensor in Australia Documents On Demand: Ph:+44.1403.276500 Ph:+65.273.2230 Ph:+613.54.281.142 1-800-736-7672 x3 Fx:+44.1403.276501 Fx:+65.273.2610 Fx:+613.54.281.172 Web:www.systemsensor.com ©1999 System Sensor.The company reserves the right to change product specifications without notice. A05-177-05.11/99(5K)•#566 ao0ou � �p TES -AN Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve C US APPROVED 3A ' 114" 112" TEST I a pusri .i � _.. .• r,F I 1 • The AGF Manufacturing Inc. Model 1011A TESTANDRAIN matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system,with the added feature of an integral Model 7000 Pressure Relief Valve w ith drainage piping. • The Model 1011A comp lies with the requirements of NF PA-13 that stipulate a pressure relief valve be installed on all gridded systems and dow nstreamof all pressure reducing valves(see reverse). • The Model 1011A TESTANDRAIN is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses,and is 300 PSI rated. • Available in a full range of sizes from 3/4" to 2" NPT and BSPT, with all specifiable orifice sizes 3/4" (2.8K),7/16 (4.2K),1/2" (5.6K),17/32" (8.0K),5/8" (11.2K, ELO),3/4" (14.0K, ESFR),and K25 as required by NFPA 13, 2007 Edi- tion(see reverse). • The included UL/FM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. • Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-p iping outlet. • Ship ped w ith relief valve and bypass drain ports p lugged to expedite pressure testing the system. • A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. • Repair kits including (1) adapter gasket,(1) ball,(2)valve seats,(1) stem packing,and (1) stem washerare avail- ab le for all TESTANDRAIN valves.Valve and orifice size must be specified w hen ordering. NOTE:It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve. Standard relief valves are required to OPEN in a range of pressure between 90%and 105% of their rating.The valves are required to CLOSE at a pressure above 80%of that rating.The relief valve should be installed where it is easily accessible for main- tenance. Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational.A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. Reliability, Versatility, Code Compatibility TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. CS1011A 10/09 AP c ® us - TE AND D -,\u,/_-,10-4e-Y '-n,a A 1- APP® Model 1011A 300 PSI Bronze Ball Valve,Model 7000 Pressure Relief Valve Factory Rated at 175 PSI with other settings available DIMENSIONS MODEL 1O11A - FRONT VIEW Orifice Size Available: 3/8", 7A6", 1/2", 17/32", ELO(5/8")", ESFR(3/a")*, &K25"" A SIZE A B C D E F G H E -1 INLET Erimirm 79/16" 11/2" 23/16" 35/8" 33/8" 113/16" 49/16" 63/8" TO 1 F —O PR �I 3/a (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) DRAINH ill — it. ' 1 II 1„ 79/16 11/2" 23/16 35/8" 33/8" 113/16 49/16 63/8" G O �, (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) `' ,z•z5 _z_,11611 11/4 715/16 111/16 29/16 41/4" 35/8" 115/16 59/16 51/2 (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1 815/16" 113/16" 31/4" 51/16" 37/8" 25/8" 81/4" 107/8" MODEL 1O11A - PLAN VIEW 1/2 (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 815/16" 113/16" 31/4" 51/16" 37/8" 25/8" 81/4" 107/8" 4 A ► 2 (227 mm) (45 mm) (81.5 mm) 1 (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) Available on 11/4" to 2" size units only "`Available on 11/2" and 2" size units only1 J 1 1 °��I i Elmilp)III �I- THE MODEL 1O11A PROVIDES ALL OF THE FOLLOWING... IIIt :_. o /. From the 2007 Edition of NFPA13 Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. T Chapter 8.16.2.4.2 Drain connections,interior sectional or floor controlvalve(s)- &8.16.2.4.3 shall be providedwith a drain connection having a minimum size as show nm Table 8.16.2.4.2. MATERIALS Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling Handle:Steel the flow of the drain. Stem: Rod Brass ChapterA.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into Ball:C.P. Brass a drain capable of accepting full flow...using an approved sight Body:Bronze test connection containing a smooth borecorrosion-resistant Valve Seat:Imp regnated Teflo if orifice giving a flow equivalent to one sprinkler... Indicator Plate:Steel Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Relief Valve:Bronze Chapter 8.17.4.2.4 shall be permitted to be installed in any location...downstream Bypass Fittings: Brass of the waterflow alarm. Bypass Tubing:Nylobraid Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion-resistant orifice, APPROVALS to provide a flow equivalent to one sprinkler... UL and ULC Listed:(EX4019 Chapter 8.17.4.3.2 The trip test connection...w ith a shutoff valve and plug not less &EX4533) than 1", at least one of which shall be brass. FM Approved Chapter 7.1.2 -a gridded wet pipe system shall be providedwith a relief valve NYC-BSA No.720-87-SM set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure, whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than 1/2" in size shall be providedon the « 4, �1 * 4, �� discharge side of the pressure-reducing valve set to operate at a ***** pressure not exceeding 175 PSI. �, Chapter A.8.16.1.2.3 -consideration should be given to piping the discharge from the x��1� (pressure relief)valve MADE IN U.S.A. USA Patent # 4741361 and Other Patents Pending AGF Manufacturing Inc. Job Name: G 100 Quaker Lane,Malvern,PA 19355 Phone:610-240-4900 FFax:610-240-4906 Architect:Engineer: www.testandrain.com Contractor: Applications:Tube,Pipe&Fittings:Copper Tube Han dbook:Table 2c-Type M Tube COPPER . orcr + 4 INNOVATIONS y�1`in a OUR ONLINE E 7fi 4TAZ111FE A service of the Copper Development Association air I.Pi0 MIMIPr ena- 5ross frilliJgIrl•Pg Jill IliP I) i .• CONTACT IPti 8ITEMAP HELP MEE Home>Applications>Tube,Pipe&Fittings>Technical References>Copper Tube Copper Tu . HOME Handbook>Table of Contents> Index of Tables>Table 2c-Type M Tube Handbook . A•OUTCDA :i / Mission . . ,) ‘ r f , • Plumbing Site Menu Who We Are __ ,_ : ! r ;a �' 'I a Press Room _ �� I t CDA Offices Membership Copper Tube Handbook: Table of Contents provides Member Login Table 2c - Type M Tube a view of the full contents of this publication and the . APPLICATIONS Dimensions and Physical Characteristics of Copper Tube: links to go to specific Architecture TYPE M sections of this handbook. Automotive Electrical Nominal dimensions,inches Calculated values(based on nominal dimensions) The entire Co er Tube Building Wire pp Nominal Weight Handbook can be Energy Efficiency or Cross Weight of tube downloaded in pdf format[7 Power Quality standard sectional of tube & Contents of Tube, Pipe& Fittings size, area of only, water tube MB]. Fuel Gas inches bore, pounds pounds per linear ft Industrial Outside Inside Wall sq. per per • diameter diameter thickness inches linear ft. linear ft. Cu ft. Gal. Marine - - - • li Machined Products 3/8 .500 .450 .025 .159 .145 .214 .00110 .00826 ,, Telecommunications 1/2 .625 .569 .028 .254 .204 r .314 .00176 .0132 - E , Copper Compounds 3/4 .875 .811 .032 .517 .328 .551 .00359 .0269 ... \ \\ _ c I COPPER g 1 1.125 1.055 .035 .874 .465 .843 .00607 .0454 y ; NU11;.MiiCALMN , 10 Antimicrobial Copper 1-1/4 1.375 1.291 .042 1.31 .682 1.25 .00910 .0681 Alloy Surfaces 1-1/2 1.625 1.527 .049 1.83 .940 1.73 .0127 .0951 2 2.125 2.009 .058 3.17 1.46 2.83 .0220 .165 I Rl30UOo46RCES AMD # 2-1/2 2.625 2.495 .065 4.89 2.03 4.14 .0340 .254 Find Suppliers Of - Copper 3 3.125 2.981 .072 6.98 2.68 5.70 .0485 .363 CDA Tube, Pipe and Copper Data Center 3-1/2 3.625 3.459 .083 9.40 3.58 7.64 .0653 .488 Fittings Council members: Standards& 4 4.125 3.935 .095 12.2 4.66 9.83 .0847 .634 Properties Applications Directory 5 5.125 4.907 .109 18.9 6.66 14.8 .131 .982 Market Data 6 6.125 5.881 .122 27.2 8.92 20.7 .189 1.41 lff Publications List 8 8.125 7.785 .170 47.6 16.5 37.1 .331 2.47 A,I,rsCCPa v,._", .:iCr • Copper Topics 10 10.125 9.701 .212 73.9 25.6 57.5 .513 3.84 tMfIpSE . •DUCATMOM I 12 12.125 11.617 .254 106 36.7 82.5 .736 5.51 http://www.copper.org/applications/plumbing/techref/cth/tables/cth table2c.htm(1 of 2)2/17/2006 1:57:15 AM EPC Wrot & Cast Pressure Fittings Couplings WROT CAST WROT CAST 100 Coupling With Stop 101 Coupling Without Stop Copper to Copper A A-I EPC EPC cxc cxc = > Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/8 30944 50 1000 0.004 11/16 1/4 30948 50 1000 0.007 23/32 1/4 30896 50 1000 0.007 3/32 3/8 30950 50 1000 0.015 55/64 3/8 30898 50 1000 0.014 3/32 1/2 30952 100 1000 0.027 1 3/3 2 1/2 30900 100 1000 0.021 3/32 5/8 30954 25 500 0.041 121/64 5/8 30902 25 500 0.040 3/32 3/4 30956 50 500 0.056 1 19/3 2 3/4 30904 50 500 0.056 3/32 1 30960 25 250 0.121 1 29/3 2 7/8 30906 10 200 0.084 3/32 11/4 30962 20 200 0.149 2 1/3 2 1 30908 25 250 0.122 3/32 11/2 30964 10 100 0.213 217/64 11/4 30910 20 200 0.144 3/32 2 30966 5 50 0.391 249/64 11/2 30914 10 100 0.216 3/32 21/2 30968 5 50 0.616 3 1/3 2 2 30916 5 50 0.391 3/32 3 30970 5 40 0.912 3 13/3 2 21/2 30918 5 50 0.624 3/32 31/2 30972 1 16 1.352 3 29/3 2 3 30920 5 40 0.909 3/32 4 30974 2 16 1.878 4 13/3 2 31/2 30922 1 16 1.369 3/32 5 30976 1 6 3.365 51/2 4 30924 2 16 1.904 3/32 6 30978 1 6 5.262 63/8 5 30926 1 6 3.365 3/16 8 30980 1 1 12.941 81/4 6 30928 1 6 5.262 3/16 8 30930 1 1 12.941 1/8 WROT CAST WROT CAST 101-R Coupling With Stop 4701-R 100-RS Coupling With Roll Stop Copper to Copper Copper to Copper .1111. -if-- 1 ir ---- 1 A Pt~ 7 - impRE - CxC it_ C x C Nominal Size Part Box Master Approx. Dim. Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A In Inches Number Quantity Pack Net Wt. A 3/160D 30662 50 1000 0.002 1/16 1/4ODx3/160D 30668 50 1000 0.004 3/32 5/160D 30672 50 1000 0.006 1/16 5/16ODx1/40D 30674 50 1000 0.007 3/32 1/8 30666 50 1000 0.004 1/16 3/80Dx5/160D 30680 50 1000 0.008 3/32 1/4 30678 50 1000 0.007 3/32 1/4x1/8 30684 50 1000 0.008 5/32 3/8 30686 50 1000 0.014 3/32 3/8x 1/4 30688 50 1000 0.017 3/16 1/2 30694 100 1000 0.021 3/32 3/8x 1/8 30692 50 1000 0.019 1/4 5/8 30702 25 500 0.040 3/32 1/2 x 3/8 30696 50 1000 0.024 5/32 3/4 30712 50 500 0.056 3/32 1/2x1/4 30698 50 1000 0.025 1/4 7/8 30724 10 200 0.084 3/32 1/2 x 1/8 30700 50 1000 0.027 23/64 1 30730 25 250 0.122 3/32 5/8x 1/2 30704 25 500 0.035 5/32 11/4 30746 20 200 0.144 3/32 5/8x3/8 30706 25 500 0.033 7/32 1 1/2 30764 10 100 0.216 3/32 5/8x 1/4 30708 25 500 0.043 5/16 2 30782 5 50 0.391 3/32 3/4x5/8 30714 50 500 0.057 3/16 4 Elkhart Products Corporation **cast Bronze Only *Factory Option-consult factory for price and delivery information. Wrot& Cast Pressure Fittings EPC Couplings & Unions WROT CAST WROT CAST 101-R Coupling With Stop-cont. 4701-R 110 Eccentric Coupling Copper to Copper Copper to Copper Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A _ - A - 3/4x 1/2 30716 50 500 0.061 3/16 3/4x 3/8 30718 25 500 0.054 21/64 3/4x 1/4 30720 25 500 0.053 7/16 1 x 3/4 30734 25 250 0.098 13/32 C x C 1 x 5/8 3 073 6 25 250 0.102 3/8 1 x 1/2 30738 25 250 0.104 7/16 1 x 3/8 30740 25 250 0.098 1/2 Nominal Size Part Box Master Approx. Dim. 1 1/4 x 1 30748 10 100 0.152 5/16 In Inches Number Quantity Pack Net Wt. A 1 1/4 x 3/4 30752 10 100 0.134 15/32 1 1/4 x 1/2 30756 10 100 0.176 41/64 3/4x 1/2 31042 25 250 0.060 3/8 1 1/2 x 1 1/4 30766 10 100 0.220 11/32 1 x 3/4 31044 10 100 0.114 13/32 1 1/2 x 1 30768 10 100 0.220 7/16 1 1/4 x 1 31046 10 100 0.162 1/2 1 1/2 x 3/4 30772 10 100 0.218 21/32 1 1/4 x 3/4 31048 10 100 0.190 3/4 1 1/2 x 1/2 30776 10 100 0.219 25/32 2 x 1 1/2 30784 10 100 0.366 13/32 2 x 1 1/4 30786 10 100 0.393 21/32 2 x 1 30788 10 100 0.383 25/32 2 x 3/4 30790 10 100 0.408 1 WROT CAST 2x1/2 30792 10 100 0.420 11/8 102 Union 4733 21/2 x 2 30800 5 50 0.639 15/32 Copper to Copper 21/2 x 1 1/2 30802 5 50 0.666 7/8 21/2 x 1 1/4 30804 5 50 0.664 15/16 21/2 x 1 30806 5 50 0.691 1 1/8 1 A 3 x 21/2 30816 2 20 0.946 1/2 3 x 2 30818 2 20 0.991 13/16 /11; rill 3 x 1 1/2 30820 2 20 1.106 1 5/32 II :' i M-_1•1 **3 x 1 1/4 34710 - 40 1.345 - **3 x 1 34712 - 25 1.352 - `tt. 31/2 x 3 30832 1 16 1.426 1/2 C x C 4 x 31/2 30840 2 3 2 1.960 17/32 4 x 3 30842 2 3 2 1.940 7/8 4 x 21/2 30844 2 32 2.029 1 1/8 Nominal Size Part Box Master Approx. Dim. 4 x 2 30846 2 32 2.192 1 1/2 In Inches Number Quantity Pack Net Wt. A 5 x 4 30850 1 6 3.310 25/32 5 x 3 30852 1 6 3.199 1 3/16 1/4 33576 25 500 0.114 13/32 5 x 21/2 30854 1 6 3.115 1 7/16 3/8 33578 25 250 0.131 27/64 5 x 2 30856 1 6 2.932 1 11/16 **3/8 37933 50 500 0.147 - 6 x 5 30860 1 6 4.762 1/2 1/2 33580 25 250 0.113 1/2 6 x 4 30862 1 6 4.689 1 3/16 **1/2 37934 25 250 0.216 - 6 x 3 30864 1 6 4.749 1 11/16 **5/8 37936 25 250 0.308 - 6 x 21/2 30866 1 6 4.665 21/16 3/4 33582 20 200 0.261 21/32 6 x 2 30868 1 6 4.780 2 3/16 **3/4 37937 25 150 0.313 - 8 x 6 30872 1 110.957 1 1/8 1 33584 10 100 0.557 7/16 8 x 5 30873 1 1 11.546 1 5/8 1 1/4 33585 5 50 0.698 7/16 8 x 4 30874 1 1 11.696 21/4 1 1/2 33586 5 50 0.878 29/64 8 x 3 30876 1 112.800 211/16 2 33587 2 20 1.499 15/32 8 x 21/2 30878 1 1 13.770 31/16 **2 1/2 37947 - 10 3.250 - 8 x 2 30880 1 1 14.163 3 **3 37948 - 5 4.750 - **Cast Bronze Only *Factory Option-consult factory for price and delvery information. Elkhart Products Corporation 5 EPC Wrot & Cast Pressure Fittings Adapters WROT CAST WROT CAST 103 Female Adapter 4703 103-2 Female Street Adapter 4703-2 Copper to Female N.P.T. Fitting to Female N.P.T. A �Ay C) I 't.' l �"""" �I Eli FTG.x F -�wrr I EPC Ill � ! Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A C x F 1/4 30224 50 1000 0.030 29/32 3/8 30230 50 1000 0.049 11/16 1/2 30236 50 500 0.084 13/8 3/4 30242 25 250 0.143 111/16 Nominal Size Part Box Master Approx. Dim. 1 30248 20 200 0.214 1 3 1/3 2 In Inches Number Quantity Pack Net Wt. A 11/4 30254 10 100 0.324 2 5/3 2 1/8 30100 50 1000 0.029 7/16 11/2 30260 10 100 0.437 27/16 1/4 30110 50 1000 0.031 15/32 2 30266 5 50 0.641 2 19/3 2 3/8 30120 50 500 0.053 19/32 **21/2 34297 - 25 1.740 - 1/2 3 013 0 50 500 0.093 7/8 **3 34298 - 20 2.470 - 3/4 30150 25 250 0.143 23/32 1/2 x 3/8 30238 50 500 0.062 1 1/8 1 30160 20 200 0.226 3 1/3 2 1/2 x 1/4 30240 50 500 0.041 59/64 11/4 30170 10 100 0.369 1 3/3 2 **3/4x1/2 34284 25 225 0.147 - 1 1/2 30180 10 100 0.404 1 5/32 **1 x 3/4 34287 25 100 0.414 - 2 30190 5 50 0.667 1 1/4 ***1 x 1/2 34288 25 250 0.153 - 21/2 30200 2 20 1.228 11/2 **3 34252 - 12 2.400 - **4 34258 - 12 3.820 - **5 34259 - 6 8.250 - I WROT CAST **6 34263 - 4 12.000 1/8x1/4 30106 50 1000 0.033 1/2 104 Male Adapter 4704 1/4 x 1/2 30112 50 500 0.078 25/32 Copper to Male N.P.T. 1/4 x 3/8 30114 50 1000 0.043 21/32 1/4x1/8 30116 50 1000 0.024 11/32 r-A-1 3/8x3/4 30122 25 250 0.121 3/4 3/8x 1/2 30124 50 500 0.082 7/8 pm 3/8x 1/4 30126 50 1000 0.041 15/32 EPCq4p 1 EC4 **1/2 x 1 34212 25 150 0.300 - 1/2x3/4 30134 25 250 0.121 29/32 • C x M 1/2x3/8 30136 50 500 0.046 9/16 1/2 x 1/4 3 013 8 50 500 0.044 15/32 5/8x3/4 30142 25 250 0.143 1 Nominal Size Part Box Master Approx. Dim. 5/8x 1/2 30144 25 250 0.102 3/4 In Inches Number Quantity Pack Net Wt. A **3/4x 1 1/4 34218 10 50 0.515 - 3/4x 1 30154 20 200 0.218 1 7/32 *1/8 30280 50 1000 0.019 13/32 3/4x 1/2 30156 25 250 0.085 19/32 1/4 30290 50 1000 0.027 15/32 **3/4x3/8 34222 25 250 0.170 - 3/8 30300 50 500 0.041 7/8 **1 x 1 1/2 34224 10 40 0.720 - 1/2 30310 50 500 0.064 19/32 1 x 1 1/4 30164 10 100 0.299 1 7/32 3/4 30330 25 250 0.119 13/16 1 x3/4 30166 25 250 0.159 43/64 1 3 03 42 20 200 0.170 27/32 1 x 1/2 30168 10 100 0.239 11/16 1 1/4 30354 10 100 0.317 15/16 **1 1/4 x 2 34229 5 50 0.980 - 1 1/2 30368 10 100 0.462 7/8 1 1/4 x 1 1/2 30172 10 100 0.431 1 19/64 2 30378 5 50 0.675 3 1/3 2 11/4x1 30174 10 100 0.238 55/64 21/2 30388 4 40 1.267 1 21/3 2 **1 1/4 x 3/4 34233 - 100 0.290 - 3 30400 2 20 1.520 1 7/32 1 1/2 x 2 30182 5 50 0.678 1 7/16 4 30410 1 16 2.262 1 9/32 1 1/2 x 1 1/4 30184 10 100 0.388 7/8 **5 34374 - 5 8.600 - **1 1/2 x 1 34238 - 60 0.370 - **6 34377 - 4 10.730 - 2 x 1 1/2 30192 5 50 0.730 1 3/16 1/8 x 3/8 30282 50 1000 0.040 3/4 6 Elkhart Products Corporation **Cast Bronze Only *Factory Option-consult factory for price and delivery information. Wrot& Cast Pressure Fittings EPC Adapters& Elbows WROT CAST WROT CAST 104 Male Adapter-cont. 4704 104-2 Male Street Adapter-cont. 4704-2 Copper to Male N.P.T. Fitting to Male N.P.T. Nominal Size Part Box Master Approx. Dim. Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A In Inches Number Quantity Pack Net Wt. A 1/8 x 1/4 30284 50 1000 0.033 7/16 1 30452 20 200 0.232 2 5/32 1/4 x 1/2 30292 50 500 0.069 7/8 1 1/4 30460 10 100 0.444 21/2 1/4 x 3/8 30294 50 1000 0.060 63/64 1 1/2 30470 10 100 0.508 213/16 1/4 x 1/8 30296 50 1000 0.014 17/32 2 30480 5 50 0.749 213/16 3/8x 3/4 30302 25 250 0.143 1 11/32 **21/2 34417 - 25 1.550 - 3/8x 1/2 30304 50 500 0.072 15/16 **3 34422 - 20 2.280 - 3/8x 1/4 30306 50 1000 0.039 5/8 1/2 x 3/4 30438 25 250 0.153 - 1/2 x 1 30314 20 200 0.240 1 1/2 x 3/8 30440 50 500 0.045 - 1/2 x 3/4 30316 25 250 0.135 13/16 3/4x 1/2 30448 25 250 0.093 1 23/32 1/2 x 3/8 30318 50 500 0.053 47/64 1/2 x 1/4 30320 50 500 0.059 5/8 5/8x3/4 30324 25 250 0.129 11/8 5/8x 1/2 30326 25 500 0.075 11/16 **3/4x 1 1/2 34329 5 50 0.596 - WROT CAST **3/4x 1 1/4 34330 - 120 0.375 - 105-C 90° Street Elbow-Close Ruff 3/4x 1 30336 20 200 0.234 7/8 Fitting to Fitting 3/4x 1/2 30338 25 250 0.106 53/64 1 x 1 1/2 30344 10 100 0.544 1 29/32 A 1 x 1 1/4 30346 10 100 0.399 1 21/32 1 x 3/4 30348 25 250 0.206 1 3/32 1 x 1/2 30350 25 250 0.176 31/32 **1 1/4 x 2 34345 - 40 0.880 I 1 1/4 x 1 1/2 30358 10 100 0.523 1 45/64 1 1/4 x 1 30360 10 100 0.304 1 1/4 A 1 1/4 x 3/4 30362 10 100 0.273 1 FTG.x FTG. 1 1/2 x 2 30370 5 50 0.772 1 25/32 + 1 1/2 x 1 1/4 30372 10 100 0.386 1 27/64 1 1/2 x 1 30374 10 100 0.435 1 9/64 **2 x 21/2 34357 25 1.565 Nominal Size Part Box Master Approx. Dim. 2 x 1 1/2 30380 5 50 0.650 1 23/64 In Inches Number Quantity Pack Net Wt. A 2 x 1 1/4 30382 5 50 0.631 1 3/4 21/2 x 2 30390 5 50 0.931 1 9/64 1/8 31450 25 500 0.008 5/8 1/4 31452 25 500 0.013 27/32 3/8 31456 25 500 0.029 15/16 1/2 31460 25 500 0.044 11/32 5/8 31464 10 200 0.073 11/4 3/4 31468 25 250 0.086 113/32 WROT CAST 1 31472 10 100 0.166 121/32 104-2 Male Street Adapter 4704-2 1 1/4 31476 5 50 0.269 1 29/32 Fitting to Male N.P.T. A 111.11ki ' FTG.x M Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A 1/4 30424 50 1000 0.033 11/6 3/8 30430 50 1000 0.049 13/16 1/2 30436 50 500 0.074 17/16 3/4 30444 25 250 0.143 127/32 **Cast Bronze Only *Factory Option-consult factory for price and delivery information. Elkhart Products Corporation 7 EPC Wrot& Cast Pressure Fittings Elbows WROT CAST WROT CAST 105-L 90° Street Elbow-Long Turn 106-2 45° Street Elbow Fitting to Fitting Fitting to Copper S y . 411111.1.11 / 1r A y IA FTG.x FTG. FTG.x C 111. 13/1l -- -' Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B Nominal Size Part Box Master Approx. Dim. 1/4 31186 50 1000 0.013 15/64 41/64 In Inches Number Quantity Pack Net Wt. A 3/8 31190 50 1000 0.024 9/32 23/32 3/8 31896 25 500 0.033 13/16 1/2 31194 100 1000 0.035 5/16 25/32 1/2 31902 25 250 0.057 17/16 5/8 31198 25 250 0.059 5/16 1 3/4 31914 25 250 0.138 2 3/4 31202 50 500 0.076 13/32 13/16 1 31926 10 100 0.251 2 15/3 2 1 31206 25 250 0.134 7/16 17/16 11/4 3 193 2 5 50 0.381 229/32 11/4 31212 25 200 0.229 17/32 19/16 11/2 3 193 8 5 50 0.563 35/16 11/2 31216 20 160 0.343 19/32 13/4 2 31944 5 40 1.156 43/8 2 31220 10 80 0.625 11/16 2 3/3 2 21/2 31224 5 40 0.965 29/32 2 7/16 3 31228 3 24 1.470 1 211/16 WROT CAST *31/2 3 123 2 1 16 2.100 1 5/3 2 3 106 45° Elbow 4 3 123 6 1 8 3.340 1 9/3 2 31/2 Copper to Copper WROT CAST 107-C 90° Elbow-Close Ruff 4707 Copper to Copper NI I \.....--imEPC B• �Pc � II g i C x C A - A A --II CxC Thli_� Nominal Size Part Box Master Approx. Dim. Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A In Inches Number Quantity Pack Net Wt. A B 1/8 31082 50 1000 0.006 1/8 1/8 31260 50 1000 0.008 3/8 3/8 1/4 31086 50 1000 0.013 15/64 1/4 31262 50 1000 0.012 3/8 3/8 3/8 31090 50 1000 0.024 1/4 3/8 31266 50 1000 0.026 13/32 13/32 1/2 31096 100 1000 0.034 17/64 1/2 31272 100 1000 0.044 25/64 25/64 5/8 31102 25 250 0.056 5/16 5/8 31280 25 250 0.069 17/32 17/32 3/4 31106 50 500 0.076 3/8 3/4 31288 50 500 0.096 9/16 9/16 1 31120 25 250 0.137 13/32 1 31296 20 200 0.208 47/64 47/64 11/4 31128 25 200 0.229 33/64 11/4 3 13 06 25 200 0.259 15/16 15/16 11/2 31134 20 160 0.343 19/32 11/2 3 13 14 20 120 0.371 111/64 111/64 2 31140 10 80 0.625 25/32 2 3 13 22 10 80 0.805 129/64 129/64 21/2 31148 5 40 0.970 7/8 21/2 31330 5 40 1.180 1 21/3 2 1 21/3 2 3 31156 3 24 1.460 63/64 3 31338 3 24 1.920 161/64 161/64 31/2 31162 1 16 2.180 1 5/3 2 31/2 3 13 46 1 8 2.728 2 7/3 2 2 7/3 2 4 31168 1 8 3.800 1 11/64 4 3 13 52 1 8 4.557 2 17/3 2 2 17/3 2 5 31170 1 6 6.564 1 13/3 2 5 3 13 60 1 1 8.586 31/8 31/8 6 31172 1 1 11.200 111/16 6 3 13 68 1 1 15.200 313/16 313/16 8 31174 1 1 27.900 21/4 8 3 13 71 1 1 37.000 51/8 51/8 8 Elkhart Products Corporation **cast Bronze Only *Factory Option-consult factory for price and delivery information. Wrot& Cast Pressure Fittings EPC Elbows WROT CAST WROT CAST 107-C-2 90° Street Elbow-Close Ruff 107-L 90° Elbow-Long Turn-cont. Fitting to Copper Copper to Copper Nominal Size Part Box Master Approx. Dim. Dim. - A f In Inches Number Quantity Pack Net Wt. A B illii 1/2 31676 50 500 0.055 55/64 55/64 5/8 31684 25 250 0.087 11/16 11/16 ' , IN 3/4 31692 25 250 0.123 15/32 15/32 7/8 31702 10 100 0.210 1 15/3 2 1 15/3 2 g 1 31708 10 100 0.270 129/64 129/64 II FTG.x C 1 1/4 31720 10 80 0.381 1 7/8 1 7/8 1 1/2 31730 10 80 0.563 2 3/16 2 3/16 • - " 2 31740 5 3 0 1.156 3 3 21/2 31750 1 10 1.980 3 3/16 3 3/16 Nominal Size Part Box Master Approx. Dim. Dim. 3 31756 1 8 4. 20 51/84 58 15/4 7 In Inches Number Quantity Pack Net Wt. A B 31/2 31762 1 1 7.4800 5 / 5 /4 4 31770 1 1 7.400 5 7/88 7 5 7/8 1/8 31390 50 1000 0.006 3/8 49/64 1/4 31392 50 1000 0.012 3/8 3/4 3/8 31396 50 1000 0.027 13/32 15/16 WROT CAST 1/2 31400 100 1000 0.042 29/64 1 1/32 107-L-2 90° Street Elbow-Long Turn 5/8 31404 25 250 0.061 17/32 1 7/32 Fitting to Copper 3/4 31408 50 500 0.103 19/32 113/32 1 31412 20 200 0.195 21/32 121/32 11/4 31416 25 200 0.259 7/8 1 29/3 2 1 1/2 31420 20 120 0.392 1 11/64 2 3/8 q y 2 31424 10 80 0.805 1 29/64 2 27/32 21/2 31428 5 40 1.187 1 3/4 3 21/64 3 31432 3 24 1.960 2 3 25/32 31/2 31436 1 8 2.798 215/64 415/644 31440 1 8 4.460 219/32 413/16 CTG.xCT ( WROT CAST di 107-L 90° Elbow-Long Turn Copper to Copper Nominal Size Part Box Master Approx. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B -g _ 1/8 31790 50 1000 0.008 1/2 7/8 igie iiii 1/4 31792 50 1000 0.019 23/64 11/16 3/8 31796 50 500 0.032 23/32 1 7/3 2 t 1/2 31802 50 500 0.055 55/64 17/16l '"...-1ill 5/8 31810 25 250 0.087 11/16 127/32 q 3/4 31816 25 250 0.139 11/8 21/16 1 31830 10 100 0.269 1 13/32 2 9/16 1 1/4 31838 10 80 0.381 1 7/8 2 29/32 C x C 1 1/2 31844 10 80 0.563 2 3/16 3 5/16 2 31850 5 30 1.156 2 31/32 4 3/8 21/2 31856 1 10 1.963 3 3/16 4 23/32 3 31862 1 8 3.300 4 5/8 6 11/3 2 Nominal Size Part Box Master Approx. Dim. Dim. 31/2 31868 1 8 3.850 4 5 31/3 2 In Inches Number Quantity Pack Net Wt. A B 4 31874 1 1 5.890 4 29/64 6 23/32 3/160D 31662 50 1000 0.007 5/16 5/16 5/16 OD 31666 50 1000 0.013 9/16 9/16 1/8 31664 50 1000 0.083 1/2 1/2 1/4 31668 50 1000 0.019 3/4 3/4 3/8 31672 50 500 0.033 23/32 23/32 **Cast Bronze Only *Factory Option-consult factorytorprice and delivery information. Elkhart Products Corporation 9 Wrot& Cast Pressure Fittings EPC Elbows WROT CAST WROT CAST 107-MT 90° Elbow-Medium Turn 107-MT-2 90°Street Elbow-MediumTurn Copper to Copper Fitting to Copper EPC B r ( l y A L.- I l A I # li--1- f di c.c B -i- FTG.x C - Nominal Size Part Box Master Approx. Dim. Dim. _ + In Inches Number Quantity Pack Net Wt. A B 1/8 31510 50 1000 0.010 3/8 3/8 Nominal Size Part Box Master Approx. Dim. Dim. 1/4 31512 50 1000 0.016 3/8 3/8 In Inches Number Quantity Pack Net Wt. A B 3/8 31516 50 1000 0.043 1/2 1/2 1/2 31522 50 500 0.068 19/32 19/32 1/8 31560 50 1000 0.010 3/8 3/4 5/8 31530 25 250 0.109 7/8 7/8 1/4 31562 50 1000 0.017 3/8 3/4 3/4 31536 25 250 0.141 13/1613/16 3/8 31566 50 1000 0.044 1/2 15/16 1 31542 10 100 0.252 1 1 1/2 31572 50 500 0.066 19/32 13/16 5/8 31578 25 250 0.104 7/8 11/2 3/4 31584 25 250 0.146 13/16 15/8 WROT CAST 1 31590 10 100 0.271 11/16 21/32 107-CR 90°ReducerElbow-Close Ruff 4707 Copper to Copper .-A-. B #111 C X C WROT CAST Nominal Size Part Box Master Approx. Dim. Dim. 107-R 90°Reducer Elbow In Inches Number Quantity Pack Net Wt. A B Copper to Copper 3/8x 1/4 31268 50 1000 0.027 5/8 39/64 1/2 x 3/8 31274 50 500 0.041 43/64 5/8 B-, 1/2 x 1/4 31276 50 500 0.034 11/16 43/64 5/8x 1/2 31282 25 250 0.077 31/32 7/8 dfirti 3/4x 1/2 31290 50 500 0.085 5/8 15/32 1 x 3/4 31298 25 250 0.146 3/4 19/32Of T1 x 1/2 31300 25 250 0.129 1 1/8 7/8 1 1/4 x 1 31308 10 100 0.229 7/8 11/16 **1 1/4 x 3/4 35212 15 90 0.338 - - 11 FTG.x C **1 1/4 x 1/2 35214 20 120 0.280 - 111 - 1 1/2 x 1 1/4 31316 10 100 0.338 1 9/64 55/64 **1 1/2 x 1 35218 - 60 0.540 Nominal Size Part Box Master Approx. Dim. Dim. **1 1/2 x 3/4 35220 72 0.455 - - **1 1/2 x 1/2 35222 12 72 0.380 - - In Inches Number Quantity Pack Net Wt. A B 2 x 1 1/2 31324 5 40 0.602 1 1/2 1 13/64 3/8x 1/4 31674 50 1000 0.027 39/64 5/8 **2 x 1 1/4 35226 - 25 0.880 - - 1/2 x 3/8 31678 50 500 0.042 5/8 43/64 **2 x 1 35228 - 30 0.780 - - 5/8x 1/2 31686 25 250 0.077 7/8 31/32 **2 x 3/4 35229 - 30 0.660 - - 3/4x 3/8 31698 50 500 0.073 11/16 27/32 21/2x2 31332 5 40 1.128 1 7/8 1 1/2 3/4x 1/2 31696 50 500 0.086 7/8 7/8 3 x 21/2 31340 3 24 1.598 2 3/32 1 3/4 3/4x 5/8 31694 25 250 0.113 1 1/16 1 5/32 **3 x 2 35242 - 20 2.753 - - 1 x 3/4 31710 25 250 0.170 1 9/64 1 1/4 4 x 3 31354 1 8 3.313 211/16 2 1 1/2 x 1 31734 5 50 0.350 1 13/32 1 11/16 *5 x 4 31362 1 6 6.542 313/32 217/32 1 1/2 x 1 1/4 31732 5 50 0.480 2 21/4 *6x4 31370 1 6 8.091 3 7/8 217/32 2 x 1 1/2 31742 5 40 0.754 2 3/16 2 5/16 10 Elkhart Products Corporation "Cast eronzeOnly *Factory Option-consult factoryforpriceanddeliveryinfonnation. Wrot& Cast Pressure Fittings EPC Tees WROT CAST WROT CAST 111 Tee 4711 111 Tee-cont. 4711 Copper to Copper to Copper Copper to Copper to Copper Nominal Size Part Box Master Approx. Dim. Dim. Dim. - .. In Inches Number Quantity Pack Net Wt. A B C I. 1/2 x 3/8x 1/2 32716 50 500 0.063 3/8 17/32 11/32 1/2 x 3/8x 3/8 32718 50 500 0.064 5/16 1/2 13/32 Mk PONO: ' .10. c 1/2 x 1/4 x 1/2 32724 50 500 0.063 3/8 21/32 11/32 ■� 1/2 x 1/4 x 1/4 32728 50 500 0.064 9/32 5/8 13/32 5/8x5/8x3/4 32736 25 250 0.170 11/16 11/16 17/32 C x C x C AB 5/8 x 5/8 x 1/2 32738 25 250 0.107 27/64 27/64 1/2 5/8 x 5/8 x 3/8 32740 25 250 0.107 27/64 27/64 21/32 Nominal Size Part Box Master Approx. Dim. Dim. Dim. 5/8x 5/8x 1/4 32742 25 250 0.107 27/64 27/64 23/32 In Inches Number Quantity Pack Net Wt. A B C 5/8x 1/2 x 1/2 32748 25 250 0.107 27/64 5/8 1/2 3/4 x 3/4 x 1 32770 10 100 0.202 3/4 3/4 17/32 1/8 32606 50 1000 0.016 13/64 13/64 7/32 *3/4 x 3/4 x 5/8 32772 25 250 0.153 1/2 1/2 3/4 3/160D 32602 50 1000 0.009 3/16 3/16 3/16 3/4 x 3/4 x 1/2 32774 25 250 0.112 25/64 25/64 19/32 5/16 OD 32622 50 1000 0.020 7/32 7/32 9/32 3/4 x 3/4 x 3/8 32776 25 250 0.130 25/64 25/64 11/16 1/4 32640 50 1000 0.028 17/64 17/64 1/4 3/4 x 3/4 x 1/4 32778 25 250 0.135 25/64 25/64 3/4 3/8 32668 50 500 0.045 5/16 5/16 3/8 "3/4x 5/8 x 5/8 32786 25 250 0.150 1/2 11/16 3/4 1/2 32700 50 500 0.059 21/64 21/64 11/32 3/4 x 1/2 x 3/4 32790 25 250 0.144 1/2 25/32 17/32 5/8 32732 25 250 0.110 7/16 7/16 1/2 3/4x 1/2 x 1/2 32794 25 250 0.109 25/64 5/8 19/32 3/4 32768 25 250 0.144 1/2 1/2 17/32 "3/4 x 1/2 x 3/8 32796 25 250 0.137 25/64 5/8 11/16 1 32818 10 100 0.239 41/64 41/64 19/32 3/4 x 1/2 x 1/4 32798 25 250 0.140 25/64 5/8 3/4 1 1/4 32866 5 50 0.397 41/64 41/64 41/64 *3/4 x 3/8x 3/4 32802 25 250 0.159 1/2 29/32 17/32 1 1/2 32910 5 50 0.540 13/16 13/16 13/16 "3/4x 3/8x 3/8 32806 25 250 0.132 25/64 23/32 11/16 2 32970 5 40 1.082 1 1/16 1 1/16 1 15/64 1 x 1 x 1 1/2 32820 5 50 0.680 1 1/4 1 1/4 1 5/32 21/2 33030 1 10 1.967 121/32 1 21/32 1 11/16 1 x 1 x 1 1/4 32822 5 50 0.405 1 5/3 2 1 5/32 31/32 3 33124 1 10 2.632 1 7/8 1 7/8 1 11/16 1 x 1 x3/4 32824 10 100 0.220 1/2 1/2 5/8 31/2 33250 1 8 4.167 2 5/32 2 5/32 21/4 "1 x 1 x 5/8 32826 10 100 0.319 1/2 1/2 15/16 4 33258 1 8 5.210 2 13/3 2 2 13/3 2 2 9/16 1 x 1 x 1/2 32828 10 100 0.183 23/64 23/64 11/16 *5 33400 1 1 7.998 2 37/64 2 37/64 2 29/32 1 x 1 x 3/8 32830 10 100 0.183 23/64 23/64 13/16 *6 33420 1 1 12.613 31/8 31/8 311/16 1 x 3/4 x 1 32836 10 100 0.290 21/32 53/64 21/32 *8 33454 1 1 32.086 41/16 41/16 4 3/4 1 x 3/4 x 3/4 32838 10 100 0.220 1/2 11/16 5/8 1/4 x 1/4 x 1/8 OD 32614 50 1000 0.016 5/16 5/16 7/32 1 x 3/4 x 1/2 32842 10 100 0.183 23/64 9/16 11/16 1/4 x 1/4 x 1/4 OD 33492 50 1000 0.016 13/64 13/64 7/32 "1 x 3/4 x 3/8 32844 10 100 0.270 23/64 9/16 13/16 1/4 x 1/4 x 5/16 OD 32608 50 1000 0.020 17/64 17/64 9/32 1 x 1/2 x 1 32856 10 100 0.290 21/32 5/64 21/32 5/16 x 5/16 x 1/4 OD 32626 50 1000 0.020 7/32 7/32 11/32 1 x 1/2 x 3/4 32858 10 100 0.220 1/2 15/16 5/8 5/16 x 1/4 x 5/16 OD 32628 50 1000 0.020 7/32 11/32 9/32 1 x 1/2 x 1/2 32860 10 100 0.185 23/64 13/16 11/16 5/16 x 1/4 x 1/4 OD 32630 50 1000 0.020 7/32 11/32 11/32 1 1/4 x 1 1/4 x 2 32868 5 40 1.352 1 3/4 1 3/4 13/8 "3/8 x 3/8x 3/160D 32650 50 1000 0.028 17/64 17/64 7/16 1 1/4 x 1 1/4 x 1 1/2 32870 5 50 0.680 1 3/16 1 3/16 1 5/32 3/8x 1/4 x 5/16 OD 32658 50 1000 0.028 17/64 13/32 11/32 1 1/4 x 1 1/4 x 1 32872 5 50 0.348 17/32 17/32 25/32 1/8 x 1/8 x 1/4 32610 50 1000 0.028 13/32 13/32 1/4 1 1/4 x 1 1/4 x 3/4 32874 5 50 0.314 7/16 7/16 3/4 1/4 x 1/4 x 1/2 32642 50 500 0.063 21/32 21/32 11/32 1 1/4 x 1 1/4 x 1/2 32876 5 50 0.259 19/64 19/64 11/16 1/4 x 1/4 x 3/8 32644 50 500 0.045 15/32 15/32 3/8 1 1/4 x 1 x 1 1/4 32882 5 50 0.405 7/8 7/8 25/32 1/4 x 1/4 x 1/8 32648 50 1000 0.028 17/64 17/64 13/32 1 1/4 x 1 x 1 32884 5 50 0.391 3/4 3/4 25/32 1/4 x 1/8 x 1/4 32656 50 1000 0.028 17/64 13/32 1/4 1 1/4 x 1 x 3/4 32886 5 50 0.297 5/8 5/8 25/32 1/4 x 1/8 x 1/8 32664 50 1000 0.028 17/64 13/32 13/32 1 1/4 x 1 x 1/2 32888 5 50 0.267 1/2 1/2 25/32 3/8x 3/8x 1/2 32672 50 500 0.063 17/32 17/32 11/32 1 1/4 x 3/4x 1 1/4 32894 5 50 0.405 7/8 7/8 25/32 3/8x 3/8x 1/4 32674 50 500 0.045 5/16 5/16 15/32 1 1/4 x 3/4x 1 32896 5 50 0.391 3/4 3/4 25/32 3/8x 3/8x 1/8 32678 50 500 0.045 5/16 5/16 39/64 1 1/4 x 3/4 x 3/4 32898 5 50 0.297 5/8 5/8 25/32 3/8x 1/4 x 3/8 32684 50 500 0.045 5/16 15/32 3/8 1 1/4 x 3/4 x 1/2 32900 5 50 0.267 1/2 1/2 25/32 3/8x 1/4 x 1/4 32686 50 500 0.045 5/16 15/32 15/32 1 1/4 x 1/2 x 1 1/4 32904 5 50 0.405 7/8 7/8 25/32 *3/8x 1/4 x 1/8 32688 50 500 0.045 5/16 15/32 5/8 "*1 1/4 x 1/2 x 1 36780 12 72 0.470 - - 3/8x 1/8 x 3/8 32694 50 500 0.045 5/16 9/16 3/8 **1 1/2 x 1/2 x 1/2 36783 5 50 0.500 - - - 1/2 x 1/2 x 1 32702 10 100 0.290 15/16 15/16 3/4 1 1/2 x 1 1/2 x 2 32912 5 50 1.352 1 37/64 137/64 13/8 1/2 x 1/2 x 3/4 32704 25 250 0.118 33/64 33/64 15/32 1 1/2 x 1 1/2 x 1 1/4 32914 5 50 0.457 11/16 11/16 13/16 1/2 x 1/2 x 5/8 32706 50 500 0.110 21/32 21/32 1/2 1 1/2 x 1 1/2 x 1 32916 5 50 0.376 9/16 9/16 13/16 1/2 x 1/2 x 3/8 32708 50 500 0.064 5/16 5/16 13/32 1 1/2 x 1 1/2 x 3/4 32918 5 50 0.332 7/16 7/16 13/16 1/2 x 1/2 x 1/4 32710 50 500 0.064 9/32 9/32 13/32 1 1/2 x 1 1/2 x 1/2 32920 5 50 0.296 21/64 21/64 29/32 1/2 x 1/2 x 1/8 32712 50 500 0.064 9/32 9/32 1/2 1 1/2 x 1 1/4 x 1 1/2 32924 5 50 0.680 1 7/32 1 3/16 1 7/32 **Cast Bronze Oniy *Factory Option-consuit factory for price and delivery information. Elkhart Products Corporation 11 EPC Wrot & Cast Pressure Fittings Tees WROT CAST WROT CAST 111 Tee-cont. 4711 111 Tee-cont. 4711 Copper to Copper to Copper Copper to Copper to Copper Nominal Size Part Box Master Approx. Dim. Dim. Dim. Nominal Size Part Box Master Approx. Dim. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B C In Inches Number Quantity Pack Net Wt. A B C 1 1/2 x 1 1/4 x 1 1/4 32926 5 50 0.661 31/32 1 3/16 1 1/16 21/2 x 1 1/2 x 1 1/2 33066 1 10 1.460 1 3/16 219/64 1 19/32 1 1/2 x 1 1/4 x 1 32928 5 50 0.591 27/32 13/16 1 1/16 21/2 x 1 1/2 x 1 1/4 33068 1 10 1.341 1 2 3/16 1 39/64 1 1/2 x 1 1/4 x 3/4 32930 5 50 0.583 11/16 7/8 31/32 21/2 x 1 1/4 x 21/2 33076 1 10 1.961 1 21/32 2 31/32 1 11/16 1 1/2 x 1 1/4 x 1/2 32932 5 50 0.460 9/16 13/16 31/32 21/2 x 1 1/4 x 2 33078 1 10 1.673 17/16 2 45/64 1 11/16 1 1/2 x 1 x 1 1/2 32936 5 50 0.680 1 5/3 2 1 1/4 1 5/32 21/2 x 1 x 21/2 33092 1 10 1.961 1 21/32 3 7/32 1 11/16 1 1/2 x 1 x 1 1/4 32938 5 50 0.661 31/32 1 5/16 1 1/16 21/2 x 3/4 x 21/2 33108 1 10 1.961 1 21/32 3 7/16 1 11/16 1 1/2 x 1 x 1 32940 5 50 0.591 27/32 1 1/8 1 1/16 **21/2 x 1/2 x 21/2 36916 10 20 2.460 - - - 11/2x1 x3/4 32942 5 50 0.583 11/16 1 31/32 3x3x4 33126 1 8 6.396 321/32 3 21/3 2 29/16 1 1/2 x 1 x 1/2 32944 5 50 0.460 9/16 13/16 31/32 3 x 3 x 21/2 33128 1 10 2.351 1 11/16 1 11/16 1 31/32 1 1/2 x 3/4 x 1 1/2 32948 5 50 0.680 1 5/3 2 1 19/64 1 5/32 3 x 3 x 2 33130 1 10 2.270 1 7/16 1 7/16 1 31/32 1 1/2 x 3/4 x 1 1/4 32950 5 50 0.661 31/32 1 1/4 1 1/16 3 x 3 x 1 1/2 33132 1 10 2.024 1 3/16 1 3/16 1 29/32 1 1/2 x 3/4 x 1 32952 5 50 0.591 27/32 1 5/16 1 1/16 3 x 3 x 1 1/4 33134 1 10 1.939 31/32 31/32 1 59/64 1 1/2 x 3/4x 3/4 32954 5 50 0.583 11/64 1 1/32 31/32 3 x 3 x 1 33136 1 10 1.757 7/8 7/8 1 59/64 1 1/2 x 3/4 x 1/2 32956 5 50 0.460 9/16 15/16 31/32 3 x3 x3/4 33138 1 10 1.691 3/4 3/4 1 13/16 1 1/2 x 1/2 x 1 1/2 32960 5 50 0.680 1 5/32 131/64 1 5/32 3 x 3 x 1/2 33140 1 10 1.542 9/16 9/16 1 11/16 **1 1/2 x 1/2 x 1 1/4 36814 5 50 0.750 - - - 3 x 21/2 x 3 33144 1 10 2.744 17/8 2 5/8 1 7/8 **2x2x3 36825 - 8 3.110 - - - 3x21/2x21/2 33146 1 10 2.351 111/16 213/32131/32 2 x 2 x 21/2 32972 1 10 1.961 2 2 1 11/16 3 x 21/2 x 2 33148 1 10 2.270 1 7/16 21/8 1 31/32 2 x 2 x 11/2 32974 5 40 0.893 3/4 3/4 1 3/32 3 x 21/2 x 1 1/2 33150 1 10 2.024 1 3/16 1 7/8 1 29/32 2 x 2 x 11/4 32976 5 40 0.742 11/16 11/16 1 1/8 3 x 21/2 x 1 1/4 33152 1 10 1.939 31/32 1 3/4 1 59/64 2 x 2 x 1 32978 5 40 0.673 1/2 1/2 1 3/32 3 x 21/2 x 1 33154 1 10 1.757 7/8 1 5/8 1 59/64 2 x 2 x 3/4 32980 5 40 0.624 7/16 7/16 1 5/32 3 x21/2 x3/4 33156 1 10 1.691 3/4 1 17/32 1 13/16 2 x 2 x 1/2 32982 5 40 0.551 5/16 5/16 1 1/8 3 x 2 x3 33162 1 10 2.744 17/8 31/16 17/8 2x11/2x2 32984 5 40 1.352 13/8 137/64 13/8 3 x 2 x 21/2 33164 1 10 2.351 111/16 223/32131/32 2 x 1 1/2 x 1 1/2 32986 5 40 1.097 1 1/32 1 19/64 1 11/32 3 x 2 x2 33166 1 10 2.270 1 7/16 2 9/16 1 31/32 2 x 1 1/2 x 1 1/4 32988 5 40 1.013 31/32 13/16 13/8 3 x 2 x 1 1/2 33168 1 10 2.024 13/16 2 5/16 1 29/32 2 x 1 1/2 x 1 32990 5 40 1.023 13/16 1 1/16 1 5/16 *3 x 2 x 1 1/4 33170 1 10 1.939 31/32 2 3/16 1 59/64 2 x 1 1/2 x 3/4 32992 5 40 0.960 11/16 11/16 11/4 *3 x2 x1 33172 1 10 1.757 7/8 2 1 59/64 2 x 1 1/2 x 1/2 32994 5 40 0.850 5/8 15/16 1 1/4 3 x 1 1/2 x 3 33180 1 10 2.744 17/8 3 9/16 1 7/8 2 x 1 1/4 x 2 32998 5 40 1.352 1 3/8 1 25/3 2 13/8 *3 x 1 1/2 x 21/2 33182 1 10 2.351 1 11/16 3 5/16 1 31/3 2 2 x 1 1/4 x 1 1/2 33000 5 40 1.097 1 1/32 13/8 1 11/32 *3 x 1 1/2 x 2 33184 1 10 2.270 1 7/16 31/8 1 31/32 2 x 1 1/4 x 1 1/4 33002 5 40 1.013 31/32 13/16 13/8 3 x 1 1/2 x 1 1/2 33186 1 10 2.024 13/16 2 25/32 1 29/32 2 x 1 1/4 x 1 33004 5 40 1.023 13/16 1 9/32 1 5/16 *3 x 1 1/4 x 3 33196 1 10 2.744 17/8 3 23/32 1 7/8 2 x 1 1/4 x 3/4 33006 5 40 0.960 11/16 1 5/32 1 1/4 3 x 1 x 3 33214 1 10 2.744 17/8 3 29/32 1 7/8 2 x 1 1/4 x 1/2 33008 5 40 0.850 5/8 1 5/64 1 1/4 3 x 3/4 x 3 33232 1 10 2.744 17/8 41/32 1 7/8 2 x 1 x 2 33012 5 40 1.352 13/8 1 25/3 2 13/8 4x4x3 33262 1 8 5.714 2 1/3 2 2 1/3 2 21/2 **2 x 1x 11/2 36852 - 25 1.150 - - - 4 x 4 x 21/2 33264 1 8 5.361 1 25/32 1 25/3 2 2 19/3 2 2 x 1 x 1 33016 5 40 1.023 27/32 1 9/32 1 11/32 4 x 4 x2 33266 1 8 4.880 1 1/2 1 1/2 2 7/16 2 x 3/4 x 2 33020 5 40 1.352 1 3/8 1 3/4 13/8 4 x 4 x 11/2 33268 1 8 4.985 13/16 1 3/16 2 9/16 2 x 3/4 x 3/4 36862 - 50 0.890 - - - 4 x 4 x 11/4 33270 1 8 4.715 13/32 1 3/32 21/2 2 x 1/2 x 2 33024 5 40 1.352 1 3/8 1 7/8 13/8 4 x 4 x 1 33272 1 8 4.502 15/16 15/16 2 5/16 21/2x21/2x3 33032 1 10 2.744 25/8 25/8 17/8 4x4x3/4 33274 1 16 2.393 13/32 13/32 25/16 21/2 x 21/2 x 2 33034 1 10 1.673 17/16 1 7/16 1 11/16 4 x 4 x 1/2 33276 1 16 2.296 1/2 1/2 2 5/16 21/2 x 21/2 x 1 1/2 33 03 6 1 10 1.460 13/16 1 3/16 1 19/32 4 x 3 x4 33280 1 8 6.396 213/32 3 21/32 2 35/64 21/2 x 21/2 x 1 1/4 33038 1 10 1.341 1 1 139/64 4 x 3 x 3 33282 1 8 5.714 2 1/3 2 31/32 21/2 21/2 x 21/2 x 1 33040 1 10 1.356 7/8 7/8 15/8 4 x 3 x 21/2 33284 1 8 5.361 1 25/32 2 29/32 2 19/3 2 21/2 x 21/2 x 3/4 33042 1 10 1.258 3/4 3/4 131/64 4 x 3 x2 33286 1 8 4.880 1 1/2 2 23/32 2 7/16 21/2 x 21/2 x 1/2 33044 1 10 1.081 1/2 1/2 1 1/2 4 x 21/2 x 4 33300 1 8 6.396 213/32 41/16 2 35/64 21/2 x 2 x 21/2 33046 1 10 1.961 1 21/32 2 1 11/16 4 x 21/2 x 21/2 33304 1 8 5.361 1 25/32 3 5/16 2 19/3 2 21/2 x 2 x 2 33048 1 10 1.673 17/16 2 3/64 1 11/16 4 x 2 x4 33320 1 8 6.396 213/32 41/2 2 35/64 21/2 x 2 x 1 1/2 33050 1 10 1.460 13/16 13/4 1 19/32 4 x2 x2 33326 1 8 4.880 1 1/2 3 17/3 2 2 7/16 21/2 x 2 x 1 1/4 33052 1 10 1.341 1 1 11/16 139/64 4 x 1 1/2 x 4 33340 1 8 6.396 2 13/32 4 29/32 2 35/64 21/2 x 2 x 1 33054 1 10 1.356 7/8 1 9/16 15/8 4 x 1 x 4 33380 1 8 6.396 213/32 5 9/32 2 25/64 21/2 x 2 x 3/4 33056 1 10 1.258 3/4 13/8 131/64 *5 x 5 x 4 33404 1 6 6.950 2 7/64 2 7/64 215/16 21/2 x 2 x 1/2 33058 1 10 1.081 1/2 1 11/32 1 1/2 *5 x 5 x 3 33406 1 6 5.604 1 9/16 1 9/16 215/16 21/2 x 1 1/2 x 21/2 33062 1 10 1.961 1 21/32 2 21/32 1 11/16 *5 x 5 x 21/2 33408 1 6 5.511 1 13/32 1 13/32 215/16 21/2 x 1 1/2 x 2 33064 1 10 1.673 17/16 2 15/3 2 1 11/16 *5 x 5 x 2 33410 1 6 4.824 1 5/64 1 5/64 2 7/8 12 Elkhart Products Corporation **Cast Bronze Only *Factory Option-consult factory f or price and delivery Wrot& Cast Pressure Fittings EPC Tees& Plugs WROT CAST WROT CAST 111 Tee-cont. 4711 Baseboard Tee 4714-B Copper to Copper to Copper Copper to Female N.P.T.to Copper Nominal Size Part Box Master Approx. Dim. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B C -Ii�--:, *5x5x11/2 33412 1 6 4.479 27/32 27/32 27/8 *5x5x11/4 33414 1 6 4.276 3/4 3/4 27/8 *5x5x1 33416 1 6 4.050 21/32 21/32 27/8 - 1 } iii...„, *5x5x3/4 33418 1 6 3.841 5/8 5/8 27/8 - _ C *5 x 4 x 5 33398 1 1 10.087 2 37/64 41/8 29/32 *5x4x4 33399 1 1 8.101 21/8 329/64215/16 CxFxC -I A -B *6x 6 x 5 33424 1 1 11.580 2 45/64 2 45/64 3 7/16 *6x 6 x 4 33426 1 1 10.132 213/64 213/64 3 7/16 *6x 6 x 3 33428 1 1 8.093 1 11/16 1 11/16 3 7/16 Nominal Size Part Box Master Approx. Dim. Dim. Dim. *6x 6 x 21/2 33430 1 1 7.663 1 7/16 1 7/16 3 7/16 In Inches Number Quantity Pack Net Wt. A B C *6x6x2 33432 1 1 7.132 1 17/32 1 17/32 37/16 *6 x 6 x 1 1/2 33434 1 6 6.716 15/16 15/16 3 7/16 **1/2 x 1/8 x 1/2 37852 40 320 0.110 - - *6x 6 x 11/4 33436 1 6 6.454 13/16 13/16 3 7/16 **1/2 x 1/8 x 3/4 37850 20 160 0.170 - - - *6 x 6 x 1 33438 1 6 6.168 11/16 11/16 3 7/16 **3/4 x 1/8 x 3/4 37855 35 210 0.186 - - - *6 x 6 x 3/4 33440 1 6 5.885 5/8 5/8 3 7/16 "1 x 1/8 x 1 37857 15 90 0.300 - - - *6x 6 x 1/2 33441 1 6 5.668 11/32 11/32 311/32 **1 1/4 x 1/8 x 1 1/4 37858 - 45 0.501 - - - *6x4x6 33443 1 1 13.252 31/8 423/32311/16 *6 x 4 x 4 33446 1 1 10.103 213/64 43/16 37/16 *8x 8 x 6 33456 1 1 26.140 31/16 31/16 41/2 WROT CAST *8x8x5 33458 1 1 23.380 29/16 29/16 41/2 116 FittingEnd Plug *8x8x4 33460 1 1 20.706 21/16 21/16 49/16 *8x 8 x 3 33462 1 1 18.308 1 1/2 1 1/2 41/2 For Fitting *8x 8 x 21/2 33464 1 1 17.650 1 23/64 1 23/64 4 9/16 *8x 8 x 2 33466 1 1 17.199 1 1/16 1 1/16 41/2 *8x 6 x 6 33468 1 1 25.984 31/16 41/2 41/2 WROT CAST1117 111-2 Street Tee Copper to Fitting to Copper -1 A + Nominal Size Part Box Master Approx. Dim. L.._ In Inches Number Quantity Pack Net Wt. A *3/8 32020 50 1000 0.010 1/16 US -I I 1/2 32022 100 1000 0.016 3/32 -1 A -B I C 3/4 32026 50 500 0.036 1/8 C x FTG.x C 1 32028 25 250 0.059 5/32 Nominal Size Part Box Master Approx. Dim. Dim. Dim. In Inches Number Quantity Pack Net Wt. A B C 1/2 33506 50 500 0.069 3/8 1 1/3 2 3/8 3/4 33508 25 250 0.147 1/2 17/16 15/32 **Cast Bronze Only *Factory Option-consult factory forprice and delivery information. Elkhart Products Corporation 13 EPC Wrot & Cast Pressure Fittings Caps& Reducers WROT CAST WROT CAST 117 Tube Cap 4717 118 Fitting Reducer-cont. For Tube End Fitting to Copper Nominal Size Part Box Master Approx. Dim. In Inches Number Quantity Pack Net Wt. A , q 3/4x 3/8 32066 50 500 0.037 1 1/16 3/4x 1/4 32068 50 500 0.049 1 1/8 1 x 3/4 32072 25 250 0.092 1 3/16 '' 1 x 5/8 32074 25 250 0.089 1 7/32 1 x 1/2 32076 25 250 0.095 1 9/32 1 x 3/8 32078 25 250 0.088 1 3/8 1 1/4 x 1 32082 10 100 0.150 1 1/4 1 114x3/4 3 2084 10 100 0.118 1 11/3 2 Nominal Size Part Box Master Approx. Dim. 1 1/4 x 1/2 32086 10 100 0.169 1 15/32 In Inches Number Quantity Pack Net Wt. A 1 1/2 x 1 1/4 32090 10 100 0.206 1 19/64 1 1/2 x 1 32092 10 100 0.203 1 17/32 1/8 30620 50 1000 0.003 1/32 1 1/2 x 3/4 32094 10 100 0.200 1 11/16 1/4 30622 50 1000 0.005 1/16 1 1/2 x 1/2 32096 10 100 0.207 1 7/8 3/8 30624 50 1000 0.010 3/32 2x11/2 32102 10 100 0.374 111/16 1/2 30626 100 1000 0.016 5/64 2 x 1 1/4 32104 10 100 0.360 1 15/16 5/8 30628 25 500 0.030 1/8 2x1 32106 10 100 0.357 21/8 3/4 3 063 0 50 500 0.036 5/64 2x3/4 32108 10 100 0.403 2 11/3 2 1 30632 50 500 0.059 1/8 2 x 1/2 32110 10 100 0.426 2 7/16 1 1/4 30634 25 250 0.108 5/32 21/2 x 2 32114 5 50 0.643 1 15/16 11/2 3 063 6 20 200 0.159 5/32 21/2x11/2 32116 5 50 0.666 21/4 2 3 063 8 10 100 0.284 5/32 21/2x11/4 32118 5 50 0.628 25/16 21/2 30640 5 50 0.469 5/32 21/2x1 32120 5 50 0.655 2 17/3 2 3 30642 5 50 0.713 3/16 3x21/2 32126 2 20 0.893 2 3/3 2 31/2 30644 1 10 0.970 3/16 3x2 32128 2 20 0.948 233/64 4 30646 1 10 1.384 7/32 3x11/2 3 213 0 2 20 1.027 211/16 ""5 34647 - 5 5.484 - 3x11/4 32132 2 20 1.029 225/32 **6 34648 - 5 9.670 - 31/2x3 32136 1 10 1.336 21/4 31/2 x 21/2 32138 1 10 1.344 2 7/16 31/2 x 2 3 2140 1 10 1.3 80 2 51/64 4 x 31/2 3 2144 2 3 2 1.850 2 23/32 WROT CAST 4x3 32146 2 32 1.860 215/16 4 x 21/2 3 2148 2 3 2 1.929 3 7/3 2 118 Fitting Reducer 4x2 32150 2 32 2.003 3 17/3 2 Fitting to Copper 5 x 4 32154 1 6 3.240 3 11/3 2 5x3 32156 1 6 3.168 313/16 5 x 21/2 32158 1 6 3.084 4 9/64 r 5x2 32160 1 6 2.901 47/16 6 x 5 3 2164 1 6 4.642 3 7/8 6x4 32166 1 6 4.556 43/8 6 x 3 3 2168 1 6 4.388 4 23/32 6 x 21/2 32170 1 6 4.304 51/32 FTG.x C 6 x 2 32172 1 6 4.517 5 7/32 8 x 6 3 2176 1 1 10.643 5 7/3 2 Nominal Size Part Box Master Approx. Dim. 8x5 32178 1 1 11.379 523/32 In Inches Number Quantity Pack Net Wt. A 8 x 4 32180 1 1 11.244 6 3/32 8x3 32182 1 1 12.291 6 19/3 2 1/4 OD x 1/8 0D 3 2040 50 1000 0.004 33/64 1/4 x 1/8 32042 50 1000 0.007 1/2 3/8x 1/4 32044 50 1000 0.014 17/32 3/8x 1/8 32046 50 1000 0.016 5/8 1/2 x 3/8 32048 50 1000 0.025 23/32 1/2 x 1/4 32050 50 1000 0.022 47/64 5/8x 1/2 3 2054 25 500 0.03 3 25/32 5/8x 3/8 32056 25 500 0.029 29/32 5/8x 1/4 32058 25 500 0.038 15/16 3/4x 5/8 32062 50 500 0.052 15/16 3/4x 1/2 32064 50 500 0.058 1 14 Elkhart Products Corporation "`Cast Bronze Only *Factory Option-consult factory for price and delivery information. ® TO L CO www.toIco.corn a brand ofNIBCO' Revision 5/24/2001 Fig. 98 - Rod Stiffener Size Range—Secures 3/8"thru 7/8" hanger rod ` Material—Carbon Steel ,_ Function—Secures channel to hanger rod for vertical seismic bracing. ''::'::'::::0.- ___• _ Finish— Electro GalvanizedT Note—Available in HDG finish or Stainless Steel materials. Ai- Order By— Figure number Fig. 99 - All Thread Rod Cut to Length Size Range—Secures 3/8"thru 7/8" rod in Dimensions •Weights 1" increments l`l` � Rod Max. Rec. Load Lbs. Material—Carbon Steel l(l(`l ��� Size For ServiceTemps Maximum Temperature—750°F � 650°F 750°F Finish— Plain `�l(((( ii�r 3/8 610 540 ll(((l(� 1/2 1130 1010 Note—Available in Electro-Galvanized and l(t( � 5/8 1810 1610 HDG finish or Stainless Steel materials. l(l( 3/4 2710 2420 Order By— Figure number,rod diameter, rod (( 7/8 3770 3360 length and finish Fig. 100 - All Thread Rod Full Lengths Size Range—Secures 3/8"thru 7/8" rod in 10' lengths Material—Carbon Steel Maximum Temperature—750°F Finish— Plain Note—Available in Electro-Galvanized and HDG finish or Stainless Steel materials. Order By— Figure number,rod diameter and finish Dimensions • Weights Max Rec.Load Lbs. • Rod For ServiceTemps Approx. Size 650°F 750°F Wt./100 1/4 240 215 12 3/8 610 540 29 1/2 1130 1010 53 5/8 1810 1610 84 3/4 2710 2420 123 7/8 3770 3360 169 1 4960 4420 222 11/4 8000 7140 360 11/2 11630 10370 510 ® Office/Manufacturing Facility1375 Sampson Ave.-Corona,CA 92879•Ph: 951.737.5599•Fax: 951.737.0330 Customer Service•800.786.5266 www.tolco.com , .. • „.} o• A gllgilm :. i I i • Expanded Appr0Va •r _ r _ c UL us i LISTED APPROVED 1.0 inim Minimum BX P/N POIT UL Max Pipe UL Test Wood FM FM Max FM Test Wood ize in. Load T Pipe Size Load Thic kness,in. 8007957 GST 10 X CPVC 1-1/2 300 1.5 8020957 SWG 10 X CPVC 1-1/2 300 1.5 8008957 GST 20 X 2-1/2 850 1.5 X 4 1475 1.5 8068925 GST 20 SS X 2-1/2 850 1.5 8010957 GST 30 X 4 1500 1.5 X 4 1475 1.5 8009925 GST 25-380 X 4 1500 1.5 8022925 SWG 25-380 X 3-1/2 - 4* 1500 1.5 8021957 SWG 20 X 2-1/2 -3** 1250 1.5 8073925 SWG 20 SS X 2-1/2 1250 1.5 8139957 SH GST 20 X 3 1050 1.5 X 4 1475 1.5 8141957 SH GST 30 X 4 1500 1.5 X 4 1475 1.5 UL Max Pipe UL Test Minimum FM Max FM Test Minimum BX P/N STEEL UL Steel FM Steel Size,in. Load Thickness,in. Pipe Size Load Thic naee in 8038957 DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8037957 DSTR 1-1/2 X 4 1500 0.035 X 4 1475 0.1050 8039957 DSTR 516 X 4 1500 0.037 X 4 1475 0.1050 8045957 DST 516 X 4 1500 0.188 X 4 1475 0.1875 8046957 TEK 50 X 4 1500 0.250 X 4 1475 0.1875 8055957 SWDR 1 X 4 1500 0.037 X 4 1475 0.0600 8056957 SWDR 516 X 4 1500 0.037 X 4 1475 0.0600 8054957 SWDR 1-1/2 X 4 1500 0.037 X 4 1475 0.0600 8137957 SH DSTR 1 X 4 1500 0.035 X 4 1475 0.1050 8150922 XP 20 X 2 750 0.027 X 4 1475 0.1050 8153922 XP 35 X 3-1/2 1250 0.043 X 4 1475 0.1050 BX P/N CONCRETE FM FM Max FM Test Material Pipe Size Load 8059957 CST 20 X 4 1475 3000 PSI 8061957 SWC 20 X 4 1475 3000 PSI * SWG 25-380 Maximum pipe s ize in compos itewood joist allowed by UL is 3-1/2” SWG 25-380 Maximum pipe s ize in wood timber or joist allowed by UL is 4" ** SWG 20 Maximum pipe size in compos itewood joist allowed by UL is 2-1/2" ** SWG 20 Maximum pipes ize in wood timber or joist allowed by UL is 3" J UL and FM tests were performed in compliance with NFPA-13 Standards. �/� ' Fastening requirement:5 times weight of water filled schedule 40 pipe plus 250 pounds. II/ UL` Bull ex www.itwbuildex.com 800-284-5339 SSS26 0506 TWO-HOLE TUBESTRAP }?500,501,502 SERIES ITEM#SUBMITTED JOB NAME SPECIFICATION LOCATION Sioux Chief 500, 501 and 502 series tube strap shall be used where necessary to fasten or secure CTS tubing and IPS piping in residential ENGINEER or commercial applications. Mount to wood,metal studs or joists using CONTRACTOR nail or screw in both holes. Minimum recommended nail penetration PO# TAG is 3/4". Referto National or Local plum bing codes for pro perhanger spacing requirements. MATERIALS J#"44 500 series:Copper, CTS 501 series:Copper-plated steel,CTS 502 series:Galvanized steel, IP S,complies with MSS SP 58 Type 26 requirements 501-2 DIMENSIONS Item No. A B C D E F Gauge Load CTS (nominal) 500-2 0.500" 1.775" 1.270" 0.645" 0.630" 0.187" 26 9 lbs 500-3 0.500" 2.125" 1.600" 0.920" 0.905" 0.187" 26 13 lbs • 501-0 0.500" 1.635" 1.100" 0.380" 0.410" 0.187" 24 4.5 lbs 501-1 0.500" 1.835" 1.315" 0.500" 0.520" 0.187" 24 6 lbs • 501-2 0.500" 1.775" 1.270" 0.645" 0.630" 0.187" 24 9 lbs 501-3 0.500" 2.125" 1.600" 0.920" 0.905" 0.187" 24 13 lbs 501-4 0.750" 2.895" 2.185" 1.140" 1.145" 0.187" 22 24 lbs 502-2 501-5 0.750" 3.400" 2.635" 1.400" 1.385" 0.285" 22 33 lbs 501-6 0.750" 4.160" 3.105" 1.675" 1.640" 0.285" 22 40 lbs 501-7 0.750" 4.580" 3.590" 2.155" 2.155" 0.285" 22 60 lbs IPS (nominal) 502-0 0.625" 1.875" 1.385" 0.480" 0.540" 0.187" 22 4.5 lbs F 502-1 0.625" 2.270" 1.660" 0.630" 0.700" 0.187" 22 6 lbs ti 502-2 0.625" 2.270" 1.765" 0.840" 0.870" 0.187" 22 9 lbs E 502-3 0.625" 2.355" 1.850" 1.050" 1.130" 0.187" 22 13 lbs ® B 502-4 0.750" 2.940" 2.315" 1.315" 1.370" 0.250" 20 24 lbs � c 502-5 0.750" 3.672" 2.925" 1.660" 1.725" 0.250" 20 33 lbs f° 502-6 0.750" 3.922" 3.165" 1.890" 1.940" 0.250" 20 40 lbs 502-7 0.750" 5.015" 4.188" 2.375" 2.410" 0.270" 18 60 lbs 502-75 1.000" 5.720" 4.688" 2.875" 3.050" 0.312" 16 60 lbs 502-8 1.000" 6.578" 5.515" 3.500" 3.670" 0.312" 16 60 lbs 502-9 1.000" 7.718" 6.718" 4.500" 4.700" 0.312" 16 60 lbs Create Item Number 50A-B_ e.g.500-2:1h"copper tube strap MATERIAL A NOMINAL PIPE SIZE B ❑ 0=Copper/CTS ❑ 0=14"* ❑ 4 =1"* ❑ 75 =21/2"*1- ❑ 1 =Copper-plated steel/CTS ❑ 1 =3/8"* ❑ 5 =11//"* ❑ 8 =3"1- 0 "*t❑ 2 =Galvanized steel/IPS ❑ 2 =1/2" ❑ 6 =11h"* ❑ 9 =4"*t ❑ 3 =34" 1117 =2"* *Not available in copper 1-Not available in copper-plated steel Sioux Chief Sioux Chief Manufacturing Company I P: 1.800.821.3944 I F: 1.800.758.5950 I www.siouxchief.com 6-16 00) ToLcr o www.tolco.com a brand of NIBCO® Revision 3/1/2007 Fig. 200 - "Trimline"Adjustable Band Hanger 0 US LISTED Size Range— 1/2" thru 8" pipe Material— Carbon Steel, Mil. Galvanized to G90 specifications Function— Forfire sprinkler and other general piping c2, purposes. Knurled swivel nut design permits hangerwO 4,1;g0.t.fR . adjustment after installation. 4 i Features— -- , 0 • (1/2" thru 2") Flared edges ease installation for ' /" all pipe types and protect CP VC plastic pipe from I. abrasion. Captured design keeps adjusting nut / from separating with hanger. Hanger is easily s installed around pipe. • (21/2" thru 8") Spring tension on nut holds it A A securely in hanger before installation. Adjusting nut is easily removed. Approvals — Underwriters' Laboratories listed (1/2" thru 8") in the USA (UL)and Canada (cUL)forsteel and CPVC plastic pipe and Factory Mutual Engineering Approved (3/4"thru 8"). Conforms to Federal 1/2 THRU 2 INCH PIPE 2 1/2 THRU 8 INCH PIPE Specifications WW-H-171E, Type 10 and Manufacturers Standardization Society SP-69,Type 10. Maximum Temperature— 650°F ..m 0 Finish— Mil. Galvanized. For Stainless Steel : materi- : als, orderTOLCOT"' Fig.200WON. ...— Order By— Figure number and pipe size I " \ 1*\ -------F-----) ‘‘\"'----.1 Dimensions•Weights Pipe Rod Size Max. Rec. Approx. Size Inch Metric A B Load Lbs. Wt./100 1/2 3/8 8mm or 10mm 31/8 25/8 400 11 3/4 3/8 8mm or 10mm 31/8 21/2 400 11 1 3/8 8mm or 10mm 33/8 25/8 400 12 11/4 3/8 8mm or 10mm 33/4 27/8 400 13 11/2 3/8 8mm or 10mm 31/8 27/8 400 14 2 3/8 8mm or 10mm 41/2 3 400 15 21/2 3/8 10mm 55/8 41/8 600 27 3 3/8 10mm 57/8 4 600 29 31/2 3/8 10mm 73/8 51/4 600 34 4 3/8 10mm 73/8 5 1000 35 5 1/2 12mm 91/8 61/4 1250 66 6 1/2 12mm 101/8 63/4 1250 73 8 1/2 12mm 131/8 83/4 1250 136 OFFICE/MANUFACTURING FACILITY•1375 SAMPSON AVE.•CORONA,CA 92879•PH: 951.737.5599•FAX:951.737.0330 90 CUSTOMER SERVICE•800.786.5266 www.tolco.com