HomeMy WebLinkAboutDRB18-0484_Approved Documents_1538512108.pdf Design ReviewBoard(DRB)
Department of Community Development
75 South Frontage Road West
TOWN OF VA 1 L ACTION FORM Vail,CO 81657
Tel: 970-479-2139
www.vailgov.com
Project Name: Garnet Mountain Investments Application Number: DR B18-0484
LLC 2018
Application Type: ExteriorAlteration Date Applied: 09/25/2018
Restoring the exteriorof the unit. We plan to redo all 8 decks on the property by
replacing all old/unsafe wood, adding more support and bringing the decks to
code by adding more balusters to reducethe space between them.There will be
no changes to the footprint or style of the deck.We also plan to repaint the body
of the household with the closest matchwe could find (SW Panda White)and the
Project Description: trim and decks with a new darkerbrown (SW French Roast).We will clean, prep
and caulk the house priorto the painting. The pavers along the parking area will
be put back in place and sealed as well. We also plan to mow and do some
minor trimming of the trees aroundthe house. The lights aroundthe house
currently do not matchwe would like to replace them all to matchwith a similar
lantern-style starry-night compliant light
CONTACTS
Contact Type: Applicant
Full Name: Garnet Mountain Investments LLC (Merrill Stillwell)
Address: 2199 ChamonixLn #5 Vail, CO 81657 Phone: 3035223771
Contact Type: Property Owner
Full Name: GARNET MOUNTAIN INVESTMENTS LLC
Address: Phone: None
Contact Type: Property Owner
Full Name: GARNET MOUNTAIN INVESTMENTS LLC
Address: Phone: None
Project Address: 5064 BLACKGORE DR A (209918218001 A) (209918218001)15064 BLACK
GORE DR B (209918218002 B) (209918218002)
Job Site Location: No
B
Legal Description: Subdivision: VAIL MEADOWS FILING 1 Lot: 4 Block: Data
Parcel Number: 209 918218002
BOARDS/STAFF ACTION
Motion By: Action: Staff Approved
Second By:
Vote: Date: 10/02/2018
Conditions:
- All exposed metal flashing, trim,flues,vents, and rooftop mechanical equipment shall be anodized, painted
(adjacentfacade/roofmaterial color or flat black), or capable of weathering so as to be non-reflective
pursuant to Section 14-10-5C, Building Materials and Design, Vail Town Code, prorto requesting final
inspections.
- Approval of this project shall lapse and become void one (1) year following the date of final approval, unless
a building permit is issued and construction is commenced and is diligently pursued toward completion.
- Design Review Board approval does not constitute a permit for building. Please consult with Town of Vail
building personnel priorto construction activities.
- Design Review Board approval shall not become valid for 20 days following the date of approval, pursuant
to the Vail Town Code, Chapter12-3-3 Appeals.
- No changes to these plans maybe made without the written consent of Town of Vail staff and/orthe
appropriate review committee(s).
Planner: Chris Neubecker
PLANNING FEE RECEIPT
TOWN OF VAIL Case # DRB18-0484
Date Printed: 10/02/2018
TOWN OF VAIL - FEES RECEIPT
Planning Summary
Type: Design Review Board(DRB) Submittal Date: 09/25/2018
Subcases: Exterior Alteration
Bond Expire D ate:
Restoring the exterior of the unit.We plan to redo all 8 decks on the property by replacing all
old/unsaf ewood, adding more support and bringing the decks to code by adding more balusters to
reduce the space between them.There will be no changes to the footprint or style of the deck.We also
plan to repaint the body of the household with the closest match we could find(SW Panda White)and
Description of Work: the trim and decks with a new darker brown(SW French Roast).We will clean, prep and caulk the
house prior to the painting.The pavers along the parking area will be put back in place and sealed as
well.We also plan to mow and do some minor trimming of the trees around the house. The lights
around the house currently do not match we would like to replace them all to match with a similar
lantern-style starry-night compliant light
Property Information
Address: 5064 BLACK GORE DR A(209918218001 A) Tax ID: 209918218001
Owner: GARNET MOUNTAIN INVESTMENTS LLC
Address: 5064 BLACK GORE DR B (209918218002 B) Tax ID: 209918218002
Owner: GARNET MOUNTAIN INVESTMENTS LLC
Contacts
Contact Type: Applicant
Company Name: Garnet Mountain Investments LLC
Full Name: Merrill Stillwell
Address: 2199 Chamonix Ln#5 Vail, CO 81657
Email: merrill.stillwell@gmail.com
Contact Type: Property Owner
Full Name: GARNET MOUNTAIN INVESTMENTS LLC
Address:
Contact Type: Property Owner
Full Name: GARNET MOUNTAIN INVESTMENTS LLC
Address:
Planning Fees
Fee Information Account Amount
DRB-Exterior Alteration 001-0000.31122.00 $20.00
Payment Information D ate Paid Payment Type Amount
DRB-Exterior Alteration 09/25/2018 Credit Card $20.00
Paid By:Web payment-Notes:Transaction ID:40960983274,auth code:68357P
FEE TOTAL $20.00
AMOUNT PAID $20.00
BALANCE DUE $0.00
75 South Frontage Road West,Vail,Colorado 81657 10/02/2018 -2:14:02 PM-Generated by:cgodfrey
1/ 1
Project:
PROGRESS Fixture Type:
LIGHTING
Location:
Contact:
CYLINDER Wall mounted • Wet location listed PROGRESS D
Specifications: P5641-31/30K
Description: Images:
The P5641 Series are ideal fora w idevariety of interiorand exteriorapplications including
residential and commercial.The Cylinders feature a 120V alternating current source and
eliminates the need fora traditional LFDdriver.This modular approach results in an encap-
sulated luminaire that unites performance,cost and safety benefits.
Construction:
Black(-31) (powdercoat)
111
Die cast and extruded aluminum construction
metal shade Dimensions:
Flicker-free dimming to 10%brightnessw ithmost ELV type dimmers
(See Dimming Notes)
Back plate covers a standard 4"hexagonal recessed outlet box Width: 6"
Mounting strap foroutlet box included Height:12"
6"ofwiresupplied „
Wet location listed w henused w ithP8798 lens cover(sold separately) Depth:8-7/8
H/CTR:4-1/2"
Performance:
Number of Modules 1
Input Power 29W
Input Voltage 120V
Input Frequency 60Hz
Lumens/LPW 1355/46 (LM-79)per module
CCT 3000K
CRI 90
Life 60,000(L70/TM-21)
EMI/RFI FCC Title 47,Part 15,Class B
Min.Start Temp -30°C
Max.Operating Temp 30°C
Warranty 5 year warranty
Labels cCSAus Wet location listed
Catalog number:
Base Finish Color Temp CRI
P5641 31 - Black / 30K-3000K Blank-90 CR I
For more information visit our website: www.progresslighting.com Progress Lighting•701 Millennium Boulevard•Greenville,SC 29607
PROGRESS
LIGHTING
CYLINDER Wall mounted • Wet location listed PROGRESS D
P5641-31/30K
Dimming Notes:
P5641 is designed to be compatiblew ithmany Electronic Low Voltage(ELV-Reverse Phase)controls.
The following is a partial list of know ncompatible dimmer controls:
Electronic Low Voltage ELV Reverse Phase Controls
Lutron Diva Series (Part Number DVELV-300P)
Lutron Nova T Series (Part Number NTELV-300)
Lutron Vierti Series (Part Number VTELV-600)
Lutron (Part Number MAELV-600)
Lutron (Part Number SPELV-600)
Leviton (Part Number AWRMG-EAW)
Leviton (Part Number 6615-P)
Digital type dimmers are not recommended.
Dimming capabilities w ill vary depending on the dimmer control,load,and circuit installation.
Alw aysreferto dimmer manufacturerinstructions or a controls specialist forspecific requirements.
Dimmer control brand names w hereidentified above are trade names or registered trademarks of each respective company.
For more information visit our website: www.progresslighting.com Progress Lighting•701 Millennium Boulevard•Greenville,SC 29607
PROGRESS
LIGHTING
CYLINDER wall mounted • Wet location listed PROGRESS D
Photometrics: P5641-31/30K
ELECTRICAL DATA P5641-31/30K
Input Voltage 120V
Input Frequency 60Hz
Input Current O.11A
Input Power 29W
Pow erFactor >0.90
THD <20%
EMI Filtering FCCTitle 47,Part 15,Class B
Operating Temperature -30°C to 30°C
Dimming Yes*
Over-voltage,over-current,short-circuit protected
*See Dimming Notes formore information
P5641-31/3oK
LED Light Engine:3000K go CRI ZONAL LUMEN SUMMARY
System Wattage:29.3 ZONE LUMENS %LUMINAIRE
Fixture delivered lumens:1342
Fixture Efficacy:46.2 0-30 564 41.6%
Spacing Criteria:1.1 o-4o 83o 61.2%
0-60 1183 87.2%
0-90 1355 ,oo.o%
90-180 0 o.o%
/� CANDELA 0-180 1355 ,00.o%
DISTRIBUTION
vo° DEG CANDELA
`` o
739
5°
5
5 743
160 ill 15 741 COEFFICIENTS OF UTILIZATION
60° 25 626 Zonal Cavity Method
435 423 %Effective Ceiling Cavity Reflectance
45 273 8o% I 70% I 50% I 30%
320 ,s• 55 151
101
o zo%Effective Floor Cavity Reflectance
65
° %Wall Reflectance
75
85 53 0
70 50 30 10 70 10 55 15 50 10
15
4e0 90 0 1 110 ,06 103 100 ,08 98 100 95 96 92
3 95 85 78 73 92 72 81 71 78 70
0° 15° 30° 5 82 70 62 57 8o 56 67 56 65 55
7 71 59 51 46 70 46 57 45 55 45
Test No.16.00021 19 63 51 43 38 61 38 49 38 48 38
Tested at 25°C Ambient in accordance to IESNA LM-79-2008 P5641-31/3oK Test No.16.0002,