A18-0057_Approved Documents_1539298137.pdf
75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspections: inspections@vailgov.com Fire - Construction Permit A18-0057 Issued: 10/11/2018 TOWN OF VAIL Property Information Address: 151 VAIL LN 11 ( 210108287011 ) Unit #: 11 Parcel Number: 210108287011 Legal Description: Subdivision: CHALETS AT THE LODGE AT VAIL Unit: 11 Contacts Contact Type: Applicant Full Name: R.J. Vik Address: PO Box 8849 77 Metcalf Road Avon, CO 81620 Phone: 9709499277 Contact Type: Property Owner Full Name: FB50 LLC SCOTT FEELEY Address: 1345 AVENUE OF THE AMERICAS FL 26 11 NEW YORK, NY 101050002 Phone: None Contractor Contractor Type: Electrical Company: Encore Electric Inc. State License #: 6146 Phone: 303-934-1234 Project Information Project Name: FB50 LLC 2018 Project Description: Relocate various fire alarm devices for Chalet 11 remodel Fees Paid Account #: 001-0000.31111.00 - Fire Alarm Permit Fee Fee Amount:$187.50 Account #: 001-0000.31123.00 - Fire Alarm Review Fee Fee Amount:$288.00 Total Paid:$475.50 Conditions Issued By: Town of Vail Fire and Emergency Services Department NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. PERMIT FEE RECEIPT Case # A18-0057 Date Printed: 09/17/2018 TOWN OF VAIL - FEES RECEIPT Permit Summary Case Number: A18-0057 Status: Created Permit Number: Date Started: 09/14/2018 Permit Type: Fire - Construction Permit Subcases Fire Alarm Lot Number: Tract B Property: 151 VAIL LN 11 (210108287011) Contacts Contact Type: Applicant Company Name: Encore Electric Full Name: R.J. Vik Address: PO Box 8849 77 Metcalf Road Avon, CO 81620 Email: rj.vik@encoreelectric.com Contact Type: Property Owner Full Name: FB50 LLC SCOTT FEELEY Address: 1345 AVENUE OF THE AMERICAS FL 26 11 NEW YORK, NY 101050002 Permit Fees Fee Information Account Amount Fire Alarm Permit Fee 001-0000.31111.00 $187.50 Fire Alarm Review Fee 001-0000.31123.00 $288.00 Payment Information Date Paid Payment Type Amount Fire Alarm Review Fee 09/17/2018 Credit Card $288.00 Paid By: - Notes: mc-robert vik Fire Alarm Permit Fee 09/17/2018 Credit Card $187.50 Paid By: - Notes: mc-robert vik FEE TOTAL $475.50 AMOUNT PAID $475.50 BALANCE DUE $0.00 09/17/2018 - 11:58:45 AM - Generated by: cgodfrey75 South Frontage Road West, Vail, Colorado 81657 1 / 1 Johnson Controls 14200 E. Exposition Ave. Aurora, Colorado 80012 www.simplexgrinnell.com Tele: (303) 355-0500 Fax: (303) 355-0615 Fire Alarm Product Data Submittal for: LODGE AT VAIL - CHALET #11 VAIL CHALET 11 151 VAIL LANE, BUILDING 5 VAIL, COLORADO VAIL, COLORADO Prepared for: VAIL CHALET 11 151 VAIL LANE, BUILDING 5 PROJECT: LODGE AT VAIL - CHALET #11 VAIL CHALET 11 PREPARED FOR: VAIL CHALET 11 TYPE: DESCRIPTION: 4098-9714 PHOTO SENSOR 4098-9733 HEAT SENSOR 4098-9792 SENSOR BASE 4098-9770 CO SENSOR BASE 4906-9104 STROBE MC WHITE CEILING 4906-9154 SPKR/STROBE MC WHITE CEILING Fax: (303) 355-0615 14200 E. Exposition Ave. Aurora, CO 80012 Sales: (303) 355-0500 Service: (303) 355-0500 Features TrueAlarm analog sensing provides: Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simplex® products: 4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details) 4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides: Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide: Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide: Fixed temperature sensing Rate-of-rise temperature sensing Utility temperature sensing Listed to UL 521 and ULC-S530 General features: Operation is for ceiling or wall mounting Listed to UL 268 and ULC-S529 Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted Designed for EMI compatibility Magnetic test feature is provided Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference: For isolator bases, refer to data sheet S4098-0025 For sounder bases, refer to data sheet S4098-0028 For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor’s present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor’s average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base’s LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base’s LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors – Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories S4098-0019-20 1/2015 ALARM Sensor Base Features Base mounted address selection: Address remains with its programmed location Accessible from front (DIP switch under sensor) General features: Automatic identification provides default sensitivity when substituting sensor types Integral red LED for power-on (pulsing), or alarm or trouble (steady on) Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test Sensor Bases 4098-9792, Standard Sensor Base 4098-9789, Sensor Base with wired connections for: 2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT): 4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC 4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required Supervised relay operation is programmable and can be manually operated from control panel Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Sensor Base Options 2098-9737, Remote or local mount supervised relay: DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay: SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay: Activates when base LED is on steady, indicating local alarm or trouble DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate: Required for surface or semi-flush mounting to 4” square electrical box and for surface mounting to 4” octagonal box Can be used for cosmetic retrofitting to existing 6-3/8” diameter base product 2098-9808, Remote red LED Alarm Indicator: Mounts on single gang box (shown in illustration to right) Description TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor’s output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. Mounting Reference Electrical Box Requirements: (boxes are by others) Without relay in the box: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With relay in the box : 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 4-7/8" (124 mm) 15/16" (24 mm) 6-3/8" (162 mm) 1/4" (6.4 mm) 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and 4" square flush box 2098-9737 Supervised Relay (mounts in base electrical box or remotely) 4098-9822 Relay(mounts in base electrical box) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. Relay Size: 2-1/2" X 1-1/2" X 1" (3.75 in 3) (64 mm X 38 mm X 25.4 mm) 4098-9860 Supervised Relay (mounts in base electrical box or remotely; 2-3/8" X 1-1/4" X 11/32" (1 in 3 ) (60.4 mm X 31.8 mm X 8.6 mm) Surface mount reference 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 1-1/2" (38 mm) minimum box depth 2 S4098-0019-20 1/2015 TrueAlarm Sensor Bases and Accessories TrueAlarm Sensors Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135° F (57.2° C) 60 ft x 60 ft (18.3 m) 20 ft x 20 ft (6.1 m) for fixed temperature only; RTI = Quick 50 ft x 50 ft (15.2 m) for fixed temperature with either rate-of-rise selection; RTI = Ultra Fast 155° F (68° C) 40 ft x 40 ft (12.2 m) Smoke Sensors: Photoelectric technology sensing 360° smoke entry for optimum response Built-in insect screens 4098-9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 2-1/8" (54 mm) LED status indicator 4-7/8" (124 mm) 4098-9714 Photoelectric Sensor with Base 4098-9733 Heat Sensor TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. 2-3/8" (60 mm) LED status indicator 4-7/8" (124 mm) 4098-9733 Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Application Reference Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-20 1/2015 TrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model Description Compatibility Mounting Requirements 4098-9792 Standard Sensor Base No options 4” octagonal or 4” square box, 1-1/2” min. depth; or single gang box, 2” min. depth 4098-9789 Sensor Base with connections for Remote LED Alarm Indicator or Unsupervised Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 4” octagonal or 4” square box Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. ** NOTE:4098-9791 and 4098-9780 are NOT compatiblewith the 2120 CDT 4098-9791** 4-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 2098-9737 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 4098-9780** 2-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 4098-9860 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay TrueAlarm Sensors Model Description Compatibility Mounting Requirements 4098-9714 Photoelectric Smoke Sensor Bases 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Refer to base requirements4098-9733 Heat Sensor TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base electrical box For use with 4098-9791 base Remote Mounting requires 4”octagonal or4”square box, 1-1/2”minimum depth Base Mounting requires 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring4098-9860 Supervised Relay, mounts remote or in base electrical box For use with 4098-9780 base 2098-9808 Remote Red LED Alarm Indicator on single gang stainless steel plate Bases 4098-9789, 4098-9791, and 4098-9780 Single gang box, 1-1/2” minimum depth 4098-9822 Unsupervised Relay, tracks base LED status; Note: Mounts only in base electrical box Bases 4098-9789, 4098-9791, and 4098-9780 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring 4098-9832 Adapter Plate Bases 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Required for surface or semi-flush mounted 4” square box and for surface mounted 4” octagonal box TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). Tyco Fire Protection Products · Westminster, MA · 01441-0001 · USA S4098-0019-20 1/2015 www.simplex-fire.com © 2015 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Operating Temperature Range 32° to 100° F (0° to 38° C) Operating Temperature Range with 4098-9733 Heat Sensor 32° to 122° F (0° to 50° C) with 4098-9714 Smoke Sensor 15° to 122° F (-9° to 50° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/min (0-1220 m/min) Housing Color Frost White 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 A, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TrueAlarm Analog Sensing Product Selection Chart Specifications Features TrueAlarm addressable CO sensor bases contain a carbon monoxide (CO) sensing module providing both CO toxic gas monitoring and enhanced fire detection: For use with 4007ES; and 4010ES or 4100ES fire alarm control panels with software revision 2.01.02 or higher For use with 4100U fire alarm control panels with software revision 12.05 or higher CO sensor bases support (and require) a TrueAlarm photoelectric, photo/heat or heat sensor (ordered separately) Model 4098-9770 provides standard features, model 4098-9771 also provides a piezoelectric sounder CO sensor bases are multi-point devices, consume only one IDNet address, and receive both communications and sensor power from the IDNet channel (the sounder base requires separate 24 VDC system power or NAC connection) Listed to UL 268, Smoke Detectors for Fire Alarm Signaling Systems and UL 2075, Gas and Vapor Detectors and Sensors; allowing systems to be listed to Standard 2034, Single and Multiple Station Carbon Monoxide Alarms Listed by ULC to CSA 6.19-01 Residential Carbon Monoxide Alarming Devices Three types of CO influenced operation are available; UL 2034 CO alarm detection; UL 2075 CO (OSHA) level monitoring for ventilation control; and multi-criteria fire sensor analysis with algorithms that combines optical and CO gas monitoring information Operation of a CO sensor base with a photoelectric or a photo/heat sensor allows: Independent sensor operation or selectable multi-sensor modes of False Alarm Reduction or Faster Detection False Alarm Reduction analyzes CO and photoelectric sensor information together to provide a sophisticated rejection of non-fire conditions normally troublesome as false alarms (steam, dust, aerosols, etc.) Faster Detection (increased sensitivity) algorithm analyzes CO and photoelectric sensor information to allow the presence of CO to implement an increased photoelectric sensitivity for high value locations (museums, electrical equipment rooms, etc.) Sounder base operation details: When connected to a panel NAC through the 4905-9835 Temporal Code Module, the sounder base can provide temporal code 3 (TC3) for fire, or temporal code 4 (TC4) for toxic carbon monoxide alarms 4905-9835 module may also be used to code other (non-fire) dedicated carbon monoxide notification appliances (refer to data sheet S4905-0006) Sounder can be manually activated from the panel Sounder operation is also listed to UL 464 as an audible notification appliance TrueAlarm CO Sensor Base with Sounder (shown with 4098-9754 Photo/Heat Sensor) Features (Continued) Panel operation summary: CO sensor data is stored and analyzed at the panel; a new CO Service Report provides easy information access (see sample on page 3) 4007ES, 4010ES, and 4100ES panels provide ten (10) year end of life status indication with CO sensor expiration notices occurring within 12 months and within 6 months, allowing service replacement planning 4100U panels provide five (5) year end of life status indication with the 12 and 6 month replacement notices Analog sensor information is digitally transmitted to the host control panel via IDNet communications for processing to evaluate and track status Carbon monoxide concentration in ppm (parts per million) is available for viewing from the panel user interface For OSHA compliant CO gas sensing, CO condition level may be programmed by concentration (must be above 30 ppm) 4100ES Audio Control Panels can provide a CO Relocation Message with Temporal Code 4 tone and Voice Evacuation (reference UCSET1393, see S4100-0034) General features: Sensors may be either wall or ceiling mounted Operation of a CO sensor base with heat sensor provides dual independent sensor operation New CO test mode allows functional testing of each sensor technology including the CO sensor Optional accessories include remote alarm LED, alarm relay, and mounting adapter plate Designed for EMI compatibility Provides magnetic test CO sensor element is easily replaced when end of service life is reached: Access to CO sensor replacement cartridge (CORC, 4098-9747) requires removal of interchangeable sensor head providing tamper monitoring (sensor removal causes a trouble condition) * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:330 for allowable values and/or conditions concerning material presented in this document. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Point Peripherals UL, ULC, CSFM Listed; TrueAlarm CO Sensor Bases for Smoke, Heat, and FM Approved* Photo/Heat Sensors using IDNet Communications S4098-0052-4 1/2015 CO Sensor Base Description Carbon monoxide (CO) is an odorless, colorless, tasteless gas produced by the incomplete combustion of heating fuels such as wood, coal, heating oil, and natural gas. CO is also a byproduct of many materials experiencing unintentional fire or even incipient fire conditions. Monitoring of CO levels can warn of physically harmful concentrations, however, sensing of CO levels below the harmful level can also provide improved understanding of incipient fire conditions when evaluated in combination with photoelectric fire sensor information from the same location. Simplex® CO sensor bases combine an electrolytic CO sensing module with a TrueAlarm analog sensor to provide a single multiple sensing assembly using one system address. The CO sensor can be enabled/disabled, used in LED/Switch modes and custom control, and can be made public for communication across a fire alarm Network. CO sensor operation is similar to other TrueAlarm sensors (photoelectric or heat). It provides current analog values, average analog value, “No Answer” troubles, “Wrong Device” troubles, over threshold, concentration in ppm, and monitors for the presence of the CO sensor. Base mounted address selection allows the address to remain with its location when the sensor is removed for service or type change. Address access is from the front, under the removable sensor. An integral red LED indicates power-on by pulsing, or alarm or trouble when steady on, and also provides test mode status (see page 3). Detailed status is available at the fire alarm control panel. CO Sensing, Detailed Operation Toxic Gas Sensing, UL 2034/UL 2075. For CO toxic gas detection, the bases provide toxic gas sensing to the UL 2034 and UL 2075 standards. Toxic gas sensing may be selected at the same time as any of the combined CO photo fire detection modes are selected. Toxic Gas Sensing, OSHA Compliant. For OSHA compliant gas sensing, the desired threshold level (above 30 ppm) is selected at the control panel as required for the application, typically for ventilation control. Refer to page 3 for additional OSHA CO monitoring information. Enhanced Fire Sensing. Each sensor provides an analog measurement digitally communicated to the control panel for analysis. At the panel, these analog values are used separately, or combined, to evaluate for conditions indicative of fire, incipient fire, excessive heat, and freeze warning. For fire, the addition of a CO sensor provides two new selectable modes of operation: Nuisance Alarm Reduction Mode and Faster Fire Detection. These two modes were developed using the results of extensive testing of actual fires performed under a wide variety of conditions. (Refer to page 4 for additional operation mode options.) Nuisance Alarm Reduction Mode allows the host control panel to combine photoelectric sensor input and CO sensor level input to reduce false alarms caused by non-fire conditions. Non-fire conditions can be steam from bathroom showers, particles from dusty environments, aerosols from personal care products, tobacco smoke, cooking smoke, or other similar conditions. CO Sensing, Detailed Operation (Continued) Nuisance Alarm Reduction Details. For applications of anticipated nuisance alarm conditions, photoelectric sensitivity is normally selected for 3.7%/ft smoke obscuration. However, the addition of CO sensing allows the host control panel to apply software verification similar to the timed alarm verification feature often used with conventional smoke detection. Faster Fire Detection. For applications where faster response to incipient or slow building fires is desired and environment appropriate, the Faster Fire Detection mode correlates the outputs of the CO sensor and the photoelectric sensor to provide increased sensitivity. This mode provides earlier detection compared to a standard sensitive photoelectric sensor setting, and also provides more false alarm reduction compared to using a sensitive setting in an area not normally considered appropriate. Faster Fire Detection Details. TrueAlarm photoelectric sensors can be selected to be as sensitive as 0.2%/ft obscuration for applications evaluated as appropriate to that level. However, if the environment is not suitable for that sensitivity level, the Faster Fire Detection mode allows the photoelectric sensor to be selected as a “standard” 2.5%/ft obscuration, but with the presence of a significant level of CO, the combination of CO and photo sensing input can allow an equivalent sensitivity approaching 0.5%/ft obscuration. The host control panel tracks two photoelectric sensitivities, the one selected for photoelectric operation only (typically 2.5%), and the CO correlation sensitivity that it adjusts depending on the amount of CO present. Control Panel Operations Smoke sensor features include: sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements, automatic individual sensor calibration checking to verify sensor integrity, automatic environmental compensation, available multi-stage alarm operation, display of sensitivity directly in percent per foot, monitoring of peak activity per sensor, alarm set point, and time of day or multi-stage alarm selection. Sensor Alarm and Trouble LED Indications. The sensor base LED pulses to indicate communications with the panel. If a sensor is in alarm, or has a trouble condition, the status is annunciated at the control panel and that base LED will turn on steady. During a system alarm, the panel will control LEDs such that a trouble indication will return to pulsing to help identify the sensors in alarm. Reported CO Sensor troubles are: Disabled, Almost Expired 12 Months, Almost Expired 6 Months, Expired (End of Life), Short, and Sensor Missing/Failed. Trouble Details. “Almost Expired” is similar to the “Almost Dirty” trouble for a photoelectric sensor. “Expired” trouble is similar to the “Dirty” trouble for a TrueAlarm photoelectric sensor. CO sensor technology does not support automatic sensitivity testing and drift compensation as is available with a photoelectric sensor. End of useful CO sensor life is based upon a set 10 year operational lifetime (5 years for 4100U panels), tracked by date code built into the CO sensor module electronics. Although the CO sensor will continue to function after the expired trouble is indicated, replacement is required to ensure proper detection accuracy. 2 S4098-0052-4 1/2015 Control Panel Operations (Continued) Panel Test Mode. To facilitate functional testing of the CO sensor, a new test mode is available in the host control panel. In this mode, the CO sensor, and installed heat or smoke sensor can be easily functionally tested. Panel Test Mode Details. When in the CO test mode, the internal multiple sensor analysis algorithms are disabled allowing each sensor to be quickly tested either individually or simultaneously, depending on the test equipment used. CO testing can be performed using a Solo Model 332 aerosol dispenser (or equal). (Testing is available through your local authorized Simplex product supplier.) The base LED will display steady ON when individual sensors are activated during test. Refer to the Application Reference section for more information. OSHA CO monitoring. For OSHA compliant gas sensing, control panel software supports custom programming based upon CO concentration levels. For example, turn on ventilation if the CO level is above X ppm and then turn off ventilation when the level drops below Y ppm (or select either value as a range if desired). This is separate from alarm set points. Multi-Point Allocation. 4007ES, 4010ES, and 4100ES control panels require only one (1) point at the host panel per CO sensor base. For 4100U control panels, the requirement is three (3) points at the host panel per CO sensor base with the 4098-9754 multi-sensor, and two (2) points for the other sensors. Depending on CO sensor base and sensor choice, up to seven (7) points can be made public to a connected Simplex Fire Alarm Network. Each CO sensor base uses a single address with “sub-points” layered underneath (such as 1-1-0, 1-1-1, 1-1-2, ….1-1-6). (Additional multi-point allocation detail is described in reference data sheet S4090-0011.) CO Sensor Base Power Requirements. Power for the standard CO sensor base is provided by IDNet communications. No additional wiring is required for upgrading of existing installed TrueAlarm sensor bases. CO sensor sounder bases do require system supplied separate 24 VDC (or NAC) wiring, the same as the standard sounder base. Accessories 2098-9808, Remote red LED Alarm Indicator mounts on a single gang box to provide status indications where the sensor location may not be readily visible. (See illustration to right.) 4098-9822, LED Annunciation Relay activates when base LED is on steady, indicating a local alarm or trouble. Contacts are DPDT, rated 2 A @ 30 VDC; 1/2 A @ 120 VAC for transient suppressed loads (requires external 24 VDC coil power). Application Reference Determine sensor locations after careful consideration of the physical layout and contents of the area to be protected. For fire alarm applications: Refer to NFPA 72, the National Fire Alarm and Signaling Code On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide. For detailed application information: Refer to 4098 Detectors, Sensors, and Bases Application Manual, Part Number 574-709. For toxic gas sensor placement and mounting: Refer to NFPA 720, Standard for the Installation of Carbon Monoxide (CO) Warning Equipment in Dwelling Units Per NFPA 720, Section 5.1 (2005 edition): 5.1.1 A carbon monoxide alarm or detector shall be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms. 5.1.2 Each alarm or detector shall be located on the wall, ceiling, or other location as specified in the installation instructions that accompany the unit. 3 S4098-0052-4 1/2015 Service Port Page 1 REPORT 6 : TrueAlarm CO Report 12:34:56am MON 06-JUN-14 Channel 1 (M1) Zone Name CUSTOM LABEL Current Value End of Life Date State M1-1-2 Conference Room 17 CO Toxic Gas 457PPM 30-MAY-24 PRI M1-2-2 Boiler Room CO Toxic Gas 0PPM 30-MAY-24 NOR TRUE ALARM CO REPORT COMPLETED Press RETURN for next Screen OR CTRL-X to abort ALARM TrueAlarm CO Service Reports TrueAlarm CO Service Reports (sample below) contain information on the CO sensors programmed in the panel displaying pertinent data such as current concentration value in ppm, End of Life date, and current state. This report allows determination of which sensors will require attention. (Sample shows 10 year life tracking with a 4007ES/4010ES/4100ES.) TrueAlarm CO Sensor Base Model Description 4098-9770 CO Base, Standard operation Select TrueAlarm sensor from list below4098-9771 CO Base with Sounder TrueAlarm Sensors, select one per CO Sensor Base Model Description 4098-9714 Photoelectric Smoke Sensor Refer to selection table below for available operation modes4098-9754 Multi-Sensor Photoelectric and Heat Sensing 4098-9733 Heat Sensor CO Base Replacement CO Cartridge and Accessories (ordered separately as required) Model Description 4098-9747 CO Replacement Cartridge (CORC) Solo 332 Aerosol Dispenser, suitable for larger diameter detectors; can be used for CO or smoke testing Solo C3 CO Aerosol Canister (case of 12) Model Description Mounting Requirements 4098-9832 Adapter Plate, required for surface mounted 4” electrical boxes Refer to page 6, mounting reference 2098-9808 Choose one if required Remote red LED Alarm Indicator on single gang stainless steel plate Single gang box, 1-1/2” minimum depth 4098-9822 Relay, tracks base LED status (unsupervised, to be mounted only in base electrical box) Mounts in base electrical box (requires 1-1/2” extension on 4” square or octagonal box) Sensor Choice M o d e Operational Mode Choices* ( = operation selected) False Alarm Reduction Faster Detection TrueSense Photo/Heat Photo Fire Heat Fire**Utility Temp.Ion Fire CO Toxic Gas† Photoelectric Smoke Sensor 4098-9714 1 — — — — — — option 2 — — option — — — option Photo/Heat Multi-Sensor 4098-9754 3 — — — option option — option 4 — — option option option — option 5 — option option option option Heat Sensor 4098-9733 6 — — — — option — option 7 — — — — option — option * NOTE: Duct detection modes are not applicable and are not available. Refer to the Multi-Point Allocation discussion on page 3 for panel point requirement information. ** Heat Fire Mode is 135° F or 155° F, fixed or rate-of-rise. † CO Toxic Gas operation is selectable as: Supervisory (which is NOT recommended if communicated off-site), Priority 2 (preferred if communicated off-site), or Utility. 4 S4098-0052-4 1/2015 CO Sensor Base Operation Options with Sensor Choice TrueAlarm Analog Sensing Product Selection Chart TrueAlarm Analog Sensor Features Sealed against rear air flow entry Electronics are EMI/RFI shielded Heat sensing: Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation Rated spacing distance between sensors: Fixed Temp. Setting UL& ULC Spacing FM Spacing, Either Fixed Temperature Setting 135° F (57.2° C) 60 ft x 60 ft (18.3 m) 20 ft x 20 ft (6.1 m) for fixed temperature only; RTI = Quick 50 ft x 50 ft (15.2 m) for fixed temperature with either rate-of-rise selection; RTI = Ultra Fast 155° F (68° C) 40 ft x 40 ft (12.2 m) Smoke Sensors: Photoelectric technology sensing 360° smoke entry for optimum response Built-in insect screens 4098-9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel. (For detailed application information about sensitivity selection, refer to Installation Instructions 574-709.) The sensor head design provides 360° smoke entry for optimum smoke response. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 6-7/16" (164 mm) 2-7/16" (62 mm) LED status indicator Thermistor guard (Multi-Sensor only) Output louvers on Sounder Base extend from front and side 2-5/16" (58 mm) CO sensor housing Dimension and Feature Reference, Photoelectric or Multi-Sensor on CO Sensor Base 4098-9754 Multi-Sensor TrueAlarm multi-sensors combines the performances of TrueAlarm photoelectric smoke sensing with TrueAlarm thermal sensing to provide both features in a single assembly. Each sensing element provides data for evaluation at the fire alarm control panel where the following four independent detection modes are evaluated: Fixed temperature heat detection Rate-of-rise heat detection TrueAlarm photoelectric smoke detection And TrueSense correlation detection TrueSense analysis correlates both thermal activity and smoke activity at a single multi-sensor location using an extensively tested covariance relationship. As a result, TrueSense detection improves response to conditions indicative of faster acting, hot flaming fires when compared to the response of either photoelectric smoke activity or thermal activity alone. 4098-9733 Heat Sensor TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to HVAC system problems. 2-9/16" (65 mm) 6-7/16" (164 mm) 4098-9733 Heat Sensor with CO Sensor Base (with CO Sensor Housing facing forward) WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. 5 S4098-0052-4 1/2015 1-1/8" (29 mm) (Photoelectric sensor shown for reference) LED status indicator 6-7/16" (164 mm) NOTES: 1. Review actual wire size, wire count, box type, and whether 4098-9822 relay is used before determining box size. 2. Mounting to flush mounted box also fits single gang handy box, 2-1/8" (51 mm) deep if wiring allows. (Not applicable if 4098-9822 relay is used.) 3. For surface mounted boxes, use 4" square box with single gang adapter plate (RACO No. 787 or equal, by others) or 4" octagonal box, both require 4098-9832 Adapter Plate. 4. When 4098-9822 relay is used, mount relay in electrical box and use 1-1/2" extension ring (by others) on 4" square or octagonal box of 1-1/2" or 2-1/8" depth as required. 5. Refer to sensor base Installation Instructions 574-707 for additional information. 6. Refer to CORC Replacement Instructions 579-791 for CO cartridge installation and replacement. 4098-9832 Adapter Plate, required for mounting to surface mounted boxes (mounts inverted) Electrical Box Requirements: (boxes are by others) Without relay: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With relay : 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring Surface mount reference 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 1-1/2" (38 mm) minimum box depth Note: Single gang adapter plate (RACO No. 787 or equal) is required when using 4" square box (by others)Relay size: 2-1/2" X 1-1/2" X 1" (64 mm X 38 mm X 25.4 mm), 3.75 cubic inches Optional 4098-9822 Relay (Mounts in base electrical box and requires additional volume, see notes below) 6-3/8" Dia. x 1/4" thick CO sensor assembly (CORC) shaded for reference 6 S4098-0052-4 1/2015 Installation Reference 7 S4098-0052-4 1/2015 General Operating Specifications Communications and Sensor Supervisory Power IDNet communications, 1 address per base Communications and Sounder Power Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical supplied from communications, no impact to alarm current LED Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Temperature Range 32° F to 100° F (0° C to 38° C) Operating Temperature Range with 4098-9733 32° F to 122° F (0° C to 50° C) with 4098-9714 or 4098-9754 15° F to 122° F (-9° C to 50° C) Humidity Range 15 to 95% RH CO Sensor Base Air Velocity Ratings per Sensor Photoelectric Sensor 4098-9714 and Multi-Sensor 4098-9754 Air velocity = 0-1000 ft/min (0-305 m/min) Housing Color Frost White Sounder Operation Sounder Voltage 18 to 32 VDC from steady external source or from NAC Alarm Current (Sounder On) 17 mA @ 24 VDC, 24 mA maximum @ 32 VDC Sounder Output 88 dBA minimum @ 10 ft (3 m) per UL Standard 464, Audible Signaling Appliance; UL Standard 268, Smoke Detectors for Fire Protective Signaling Systems and CSA 6.19-01 Sounder Power Supervision (Selectable) Supervised Select for continuous 24 VDC power, loss of power is communicated to panel Unsupervised Select when connected to NAC for sounder power, NAC provides supervision NAC Powered Operation When in alarm, will sound when NAC is in alarm, allowing synchronized pattern (Temporal or March Time, etc.) controlled by the NAC control Reference for CO Monitoring Requirements Reference for UL 2034 and CSA 6.19-01 Concentration Alarm Window Response Time 70 ±5 ppm 60 to 240 minutes 150 ±5 ppm 10 to 50 minutes 400 ±10 ppm 4 to 15 minutes False Alarm Resistance 30 ±3 ppm No Alarm for 30 days 70 ±5 ppm No Alarm for 60 minutes Additional UL 2034 CO Sensor Toxic Gas Monitoring Details 1. For CO levels above 40 ppm, the CO alarm level per sensor is determined by calculations performed at the panel based on the time integrated CO levels measured at the sensor. (Levels below 40 ppm are not tracked.) 2. While tracking levels above 40 ppm, if the concentration dips below 40 ppm for periods of time, the time to alarm is extended accordingly. UL 2075 Reference, Commercial OSHA Type Operation; Utility Point Mode With custom control at the fire alarm control panel, Utility Point operations can be performed at lower CO concentration levels than those of UL 2034 Example: Start ventilation after 5 minutes at 25 to 35 ppm and also alarm at a reading higher than that range, but lower than UL 2034 allows 4098-9822 Unsupervised Relay Option Externally Supplied Relay Voltage 18-32 VDC, steady source recommended (wires to remote LED leads) Alarm Current 13 mA from separate 24 VDC supply Contact Ratings, DPDT contacts for resistive/suppressed loads Power limited rating: 2 A @ 30 VDC Non-power limited rating: 1/2 A @ 120 VAC Relay Operation Tracks base LED status, relay is on with trouble or alarm at the base Specifications Product Data Sheet Product Data Sheet Temporal Code 4 Module S4905-0006 4100ES Control Panels with EPS Power Supplies S4100-0100 Standard Bases S4098-0019 4100ES Standard Control Panels S4100-0031 Isolator Bases S4098-0025 4100ES Audio Control Reference S4100-0034 Standard Sounder Base S4098-0028 4010ES Control Panels S4010-0004 TrueSense Multi-Sensor S4098-0024 4007ES Hybrid Control Panels S4007-0001 Tyco Fire Protection Products · Westminster, MA · 01441-0001 · USA S4098-0052-4 1/2015 www.simplex-fire.com © 2015 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are trademarks of the National Fire Protection Association (NFPA). Additional Information Reference Features Visible only (V/O) 24 VDC notification appliances with high output xenon strobe, available for wall or ceiling mount: Intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Operation is compatible with ADA requirements (refer to important installation information on page 3) Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit (NAC) Regulated circuit design ensures consistent flash output and provides controlled inrush current Rugged, high impact, flame retardant thermoplastic housings are available in red or white with clear lens Listed to UL 1971 and ULC S526 Strobes provide synchronized flash for use with: Simplex® fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync two-wire control 4009 IDNet NAC Extenders Separate strobe Synchronization Modules that are available for Class B or Class A operation Separate SmartSync Control Modules (SCMs) that provide Class B or Class A output from conventional NAC inputs Strobe housings provides flexible, easy, and convenient semi-flush or surface wall mounting: Rear of housing does not extend into box Wall mount strobes easily mount to single gang, double gang, or 4-inch square outlet box Ceiling mount strobes mount to single gang boxes Wall mount strobe features: Wiring terminals are accessible from the front of the housing providing easy access for installation, inspection, and testing Covers are available separately to convert housing color Optional adapters and wire guards: Wall mount strobe adapters are available to cover surface mounted electrical boxes and to adapt to Simplex 2975-9145 boxes UL listed red wire guards are available for wall or ceiling mount strobes* * Refer to page 2 for guard listing. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning material presented in this document. Refer to page 2 for listing status of wire guards. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Wall Mount Strobes Ceiling Mount Strobes Description Multi-Candela TrueAlert synchronized strobes provide convenient installation to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount strobe housings are a one-piece assembly (including lens) that mounts to a single or double gang, or 4” square standard electrical box. The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount strobes install using standard single gang electrical boxes. Color choice is determined by model number. Strobe Intensity Selection During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. Strobe Application Reference Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC) Acceptance* Non-Addressable, SmartSync Operation Compatible S4906-0001-5 11/2014 Synchronized Strobes Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. These multi-candela strobes are synchronized over a two-wire circuit when connected to compatible NACs, to compatible Synchronized Flash Modules, or to SmartSync Control Modules. SmartSync Two-Wire Control Some applications desire the audible notification appliances to be capable of being silenced before the alarm condition is reset (on-until-silenced) while the visible notification appliances are kept activated until the alarm condition is reset (on-until-reset). SmartSync operation mode provides this function using a single circuit (two-wire operation). SmartSync Control Sources SmartSync two-wire control is available from: 4006, 4007ES Hybrid, 4008, 4010, 4010ES, 4100ES, and 4100U Fire Alarm Control Panels (refer to individual product data sheets for more information) 4009 IDNet NAC Extenders (refer to data sheet S4009-0002) SmartSync Control Module (SCM) Model 4905-9938 (refer to data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination horn/strobe notification appliances. 2 S4906-0001-5 11/2014 Multi-Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color “FIRE” Lettering Description 4906-9101 Wall Red White Multi-candela strobe with intensity selectable as: 15, 30, 75, or 110 candela; synchronized flash rate; SmartSync two-wire control compatible 4906-9103 White Red 4906-9102 Ceiling Red White 4906-9104 White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2” (38 mm) deep surface mounted boxes 5-3/8” H x 5-1/4” W x 1-5/8” D (136 mm x 133 mm x 41 mm) Total depth with strobe = 4-3/8” (111 mm)4905-9940 White 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box (typically for retrofit, may be mounted vertical or horizontal) 8-5/16” x 5-3/4” x 0.060” Thick (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8" x 5-1/8" x 2-3/4" D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate; zinc plated; required for mounting to handy box; not needed when using 4905-9926 guard 4-7/8” x 3-1/8” x 0.060” D (124 mm x 79 mm x 1.5) Synchronization Modules (refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module; epoxy encapsulated with in/out 18 AWG (0.82 mm2) wire leads, rated for 2 A NAC, requires 5 mA for power 1-3/8” x 2-7/16” x 13/16” (35 mm x 62 mm x 20 mm)4905-9922 Class A 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4” (102 mm) square box 4” x 4-1/8” x 1-1/4” D (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white “FIRE” lettering For Wall mount strobes 5-1/8” H x 5” W x 1-1/2” D (130 mm x 127 mm x 38 mm)4905-9993 White cover with red “FIRE” lettering 4905-9961* Wall mount Red wire guard with mounting plate, compatible with semi-flush or surface mounted boxes 6-1/16” H x 6-1/16” W x 3-1/8” D (154 mm x 154 mm x 79 mm) 4905-9926* Ceiling mount 6-1/8” x 4-3/8” x 2-7/8” deep (156 mm x 111 mm x 73 mm) * UL listed by Space Age Electronics Inc. Product Selection 3 S4906-0001-5 11/2014 Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC; see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32° to 122° F (0° to 50° C) Humidity Range 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm2 to 3.31 mm2); two wires per terminal for in/out wiring Wall Mount Housing Dimensions (with lens) 5-1/8” H x 5” W x 2-3/4” D (130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 60 mA 94 mA 186 mA 252 mA Reference RMS Currents at other voltages 18 VDC 53 mA 84 mA 165 mA 224 mA 24 VDC 40 mA 63 mA 124 mA 168 mA Ceiling Mount Housing Dimensions (with lens) 4-3/4” L x 2-5/16” W x 2-5/8” D (121 mm x 75 mm x 67 mm) Maximum RMS Current Rating per Strobe Setting (see Note 2 below) 15 cd 30 cd 75 cd 110 cd 75 mA 125 mA 233 mA 316 mA Reference RMS Currents at other voltages 18 VDC 67 mA 111 mA 207 mA 281 mA 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. “Regulated 24 VDC” refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired. This voltage range is the absolute operating range. Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Removable cover (tool required) Mounting is compatible with single gang, double gang, and 4" (102 mm) square boxes, 1-1/2" (38 mm) deep, by others 2 1 Mounting Holes: 4" square (4) Single gang (2) Double gang (3) Wiring access hole Wiring terminals Transparent housing and lens assembly Strobe intensity viewing slot Intensity selection plug, accessible only from rear of housing; factory setting is 15 cd 110 75 30 15 IMPORTANT! WALL MOUNT INSTALLATION HEIGHT REFERENCE a NFPA 72 requires that the entire lens be not less than 80" and not greater than 96" above the finished floor Electrical box outline 80" (2.03 m) minimum Bottom of lens is either even with, or slightly above bottom of compatible boxes Installation Reference, Surface or Semi-Flush Wall Mounting Strobe Specifications Surface Mounting Reference with Optional Adapter Skirt and Optional Wire Guard 2975-9145 Box 4905-9931 Adapter Plate 4905-9961 Optional Wire Guard (shown here for reference only, can be used on other mounting options) 4905-9931 Adapter Plate 4" (102 mm) square box profile, 1-1/2" (38 mm) deep Surface mount conduit and box shown for reference Strobe Optional 4905-9961 Wire Guard Optional Surface Mount Adapter Skirt, 1-1/2" deep: 4905-9937, Red; 4905-9940, White (conduit knockouts are provided on all four sides)1107530154905-9910 Adapter Plate, required for surface mount with handy box unless using the 4905-9926 wire guard Handy box, 1-1/2" ( 38 mm) deep (RACO 650 or equal) or single gang box, 2-1/2" (64 mm) deep (RACO 519 or equal) supplied by others Also can be attached to boxes mounted to drop ceiling T-bar with clips (ERICO No. 512 or equal) Single gang box (Wiremold V5744S) 2-1/4" (57 mm) deep, supplied by others Ceiling mount strobe Optional 4905-9926 wire guard with mounting plate Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd Tyco Fire Protection Products · Westminster, MA · 01441-0001 · USA S4906-0001-5 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Ceiling Mount Strobe Installation Reference Features Speaker/visible (S/V) notification appliances with multi-tapped speaker and multi-tapped high intensity xenon strobe with synchronized flash: Rugged, high impact, flame retardant thermoplastic housings are available for wall or ceiling mount Operation is compatible with ADA requirements (refer to important wall mount installation information on page 4) Wall mount S/V features: Housings are available in red or white with clear lens with contrasting white or red “FIRE” lettering Covers are available separately to convert housing color Ceiling mount S/V features: Housing is white with clear lens Red “FIRE” lettering is printed on two sides Audible notification appliance (speaker): High quality voice and tone reproduction with taps for ¼, ½ , 1, or 2 W, at 25 or 70.7 VRMS Capacitor input for connection to supervised notification appliance circuits Speakers are wired separately from strobe wiring UL listed to Standard 1480 and ULC-S541* Compliant with NFPA 72, 520 Hz Low Frequency Signal Requirements for Sleeping Areas Visible notification appliance (strobe): 24 VDC xenon strobe; intensity is selectable as 15, 30, 75, or 110 candela with visible selection jumper secured behind strobe housing Strobes are activated from NACs selected to provide Simplex® strobe synchronization signals or from separate strobe Synchronization Modules that are available for Class B or Class A operation Regulated circuit design ensures consistent flash output and provides controlled inrush current UL listed to Standard 1971 and ULC-S526* Options for wall mounted S/Vs: Red or white adapters to cover surface mounted electrical boxes Red adapter for mounting to Simplex 2975-9145 boxes Red wire guard * See page 2 for additional listing details and wire guard listings. This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7320-0026:247 for allowable values and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Wall and Ceiling Mount S/Vs Description Multi-Candela TrueAlert S/Vs with speaker and synchronized strobe provide convenient installation to standard electrical boxes with extensions. The enclosure designs are both impact and vandal resistant and provide a convenient strobe intensity selection. Since each model can be selected for strobe intensity output, on-site model inventory is minimized and changes encountered during construction can be easily accommodated. Wall mount S/V housings are a one-piece assembly (including lens) that mounts to a 4” square electrical box with extension (see details on page 4). The cover can be quickly removed (a tool is required) and covers are available separately for color conversion. Ceiling mount S/Vs also install using 4” electrical boxes with an extension (see details on page 4). Strobe Intensity Selection During installation, a selection plug at the back of the housing determines the desired strobe intensity. An attached flag with black letters on a highly visible yellow background allows the selected intensity to be seen at the side of the strobe lens. TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Speaker MEA (NYC) Acceptance* and Multi-Candela Strobe; Non-Addressable S4906-0003-8 5/2014 Synchronized Strobes Multiple Strobes. When multiple strobes and their reflections can be seen from one location, synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of random flashing. The multi-candela strobes of these S/Vs are activated by NACs that provide the Simplex synchronization format. For additional information, refer to data sheet S4905-0003. Strobe Application Selection Proper selection of visible notification is dependent on occupancy, location, local codes, and proper applications of: the National Fire Alarm and Signaling Code (NFPA 72), ANSI A117.1; the appropriate model building code: BOCA, ICBO, or SBCCI; and the application guidelines of the Americans with Disabilities Act (ADA). 2 S4906-0003-8 5/2014 Wall Mount Multi-Candela S/Vs Model Housing Color “FIRE” Lettering Listings Description Housing Dimensions with Lens 4906-9151 Red White UL & ULC Multi-tapped Speaker with Multi-Candela Synchronized Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela 7 ¼ H x 5 W x 2 ⅝ D (184 mm x 127 mm x 67 mm)4906-9153 White Red Ceiling Mount Multi-Candela S/V Model Housing Color “FIRE” Lettering Listings Description Dimensions 4906-9154 White Red UL Multi-tapped Speaker with Multi-Candela Synchronized Strobe; strobe intensity selectable as: 15, 30, 75, or 110 candela Housing = 7 ½ (191 mm) diameter, ½ (13 mm) deep Strobe lens protrusion = 2 ⅝ (67 mm) above speaker housing Depth into box = 2 ¾ (70 mm)4906-9157 White Red ULC Wall Mount S/V Adapters Model Description Dimensions 4905-9946 Surface mount red adapter skirt Required when mounting to surface mounted electrical box, 4 square, 1 ½ deep with 1 ½ deep extension 7 ¾ H x 5 ⅜ W x 3 3®16 D (197 mm x 137 mm x 81 mm) depth with S/V = 5 ⅞ (149 mm) 4905-9947 Surface mount white adapter skirt 4905-9903 Adapter Plate, red, required to mount S/V on 2975-9145 8 5®16 " H x 5 ¾" W x 0.060 Thick (211 mm x 146 mm x 1.5 mm) 2975-9145 Mounting box, red, for surface or flush mount, requires adapter plate 4905-9903 (this box may be available for retrofit applications) 7 ⅞" H x 5 ⅛" W x 2 ¾" D (200 mm x 130 mm x 70 mm) Wall Mount S/V Replacement Covers Model Description Dimensions 4905-9996 Red S/V cover with white FIRE lettering 7 ¼ H x 5 W x 1 ⅜ D (184 mm x 127 mm x 35 mm) 4905-9997 White S/V cover with red FIRE lettering Synchronized Flash Control Modules Model Description Dimensions 4905-9914* Synchronized Flash Module, Class B operation Epoxy encapsulated with in/out 18 AWG (0.82 mm2) wire leads, rated for 2 A NAC, requires 5 mA for power 1 ⅜ W x 2 7 ®16 L x 13®16 H (35 mm x 62 mm x 20 mm)4905-9922* Synchronized Flash Module, Class A operation Wall Mount S/V Wire Guard Model Description Dimensions 4905-9998 Wire guard with mounting plate, red, compatible with surface and semi-flush boxes (UL listed by Space Age Electronics Inc.) 8 ⅜ H x 6 5®16 W x 3 ¼ D (213 mm x 154 mm x 79 mm) Ceiling Mount Tile Bridge Model Description Dimensions 2905-9946 Tile Bridge See diagram on page 4 * Refer to data sheet S4905-0003 for additional flash control module information Product Selection 3 S4906-0003-8 5/2014 Common Specifications Environmental 32° to 122° F (0° to 50° C); 10% to 93%, non-condensing at 100° F (38° C) Connections Terminal blocks for 18 AWG to 12 AWG (0.82 mm 2 to 3.31 mm 2); two wires per terminal for in/out wiring Speaker Specifications Input Voltage 25 or 70.7 VRMS, see Note 1 below Power Taps ¼, ½, 1, and 2 W Frequency Response Fire Alarm 400 to 4000 Hz General Signaling 125 to 12 kHz Speaker Output Ratings @ 10 ft (3 m) (see Note 1 below) Wattage Tap ¼ W ½ W 1 W 2 W UL Listed Models, Reverberant Chamber Test, per UL 1480 76 dBA 79 dBA 82 dBA 85 dBA Wall Mount Models 4906-9151 and 4906-9153, Anechoic Chamber Test, per ULC-S541 77 dBA 80 dBA 83 dBA 86 dBA* Ceiling Mount Model 4906-9157, per ULC-S541 25 VRMS Input 81.6 dBA 84.3 dBA 87.1 dBA* 89.7 dBA* 70.7 VRMS Input 80.9 dBA 84.1 dBA 87.3 dBA* 90.2 dBA* * NOTE: Select taps as indicated to satisfy the ULC fire alarm applications requirement of 85 dBA minimum Polar Dispersion Reference (per ULC-S541 Anechoic Chamber Testing) Attenuation Angle Attenuation Angle -3 dB +/- 30° off-axis -6 dB +/- 55° off-axis Strobe Specifications Rated Voltage Range Regulated 24 VDC; 16 VDC to 33 VDC, see Note 2 below Flash Rate and Synchronized NAC Loading 1 Hz; with up to 35 synchronized strobes maximum per NAC Wall Mount Housing Dimensions (with lens) 7 ¼ H x 5 W x 2 ⅝ D (184 mm x 127 mm x 67 mm) Maximum RMS Current Rating per Strobe Setting 15 cd 30 cd 75 cd 110 cd 60 mA 94 mA 186 mA 252 mA Reference RMS Currents at other voltages 18 VDC 53 mA 84 mA 165 mA 224 mA 24 VDC 40 mA 63 mA 124 mA 168 mA Ceiling Mount Housing Dimensions Speaker housing = 7 ½ (191 mm) diameter, ½ deep (13 mm); lens protrusion above speaker housing = 2 ⅝ (67 mm); depth into box = 2 ¾ (70 mm) Maximum RMS Current Rating per Strobe Setting 15 cd 30 cd 75 cd 110 cd 75 mA 125 mA 233 mA 316 mA Reference RMS Currents at other voltages 18 VDC 67 mA 111 mA 207 mA 281 mA 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. Speakers are for connection to conventional fire alarm audio circuits. Anechoic speaker output ratings are typically more representative of actual installed sound output. 2. The maximum RMS strobe current listed is the device nameplate rating. Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) 75 76 77 78 79 80 81 82 83 84 85 90 80 70 60 50 40 30 20 10 0 10 20 30 40 50 60 70 80 90 Angular Displacement (Degrees) on Horizontal AxisSound Pressure Level (dB) at 10 ft (3 m)2kHz 4kHz Speaker Directional Characteristics Reference S/V Specifications Standard Electrical Box MountingMounting to 2975-9145 Box 4905-9903 Adapter Plate 2975-9145 Box Transparent housing and lens assembly Wiring input terminals and speaker tap selection are accessible from rear Speaker assembly Strobe assembly Removable cover (tool required) 4" (102 mm) square box, 1-1/2" (38 mm) deep, with a 4" square box extension, 1-1/2" deep, by others Strobe intensity viewing slot Intensity selection plug, accessible only from rear of housing; factory setting is 15 cd 110 75 30151107530154" (102 mm) square, 1-1/2" (38 mm) deep box with 1-1/2" extension (by others) Wiring input terminals and speaker tap selection are accessible from rear of speaker housing Strobe intensity viewing slot Intensity selection plug, accessible only from rear of lens housing; factory setting is 15 cd 13-3/8" (340 mm) 1/4" diameter (6 mm) holes, 4 places 0.024" thick sheet metal, folded with 1/2" lip each side 3-3/4" (95 mm) square cutout, centered on plate 23-11/16" (602 mm) 6-11/16" (170 mm) 1/2" (13 mm) 2905-9946 Tile Bridge IMPORTANT ! INSTALLATION MOUNTING HEIGHT REFERENCE NFPA 72 requires that the entire lens be not less than 80" and not greater than 96" above the finished floor. 4" square box outline 4" (102 mm) 1-1/2" (38 mm)82" (2.1 m) minimum 78-1/2" (2 m) minimum 2975-9145 box outline CL 4" (102 mm) square box profile, 1-1/2" (38 mm) deep with 1-1/2" extension Surface mount conduit and box shown for reference S/V Optional 4905-9998 Wire Guard Surface mount adapter skirt, 3-3/16" (81 mm) deep, required for this mounting method: 4905-9946, Red; 4905-9947, White (conduit knockouts are provided on all four sides) Surface Mounting Reference Showing Optional Wire Guard TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association (NFPA). Tyco Fire Protection Products · Westminster, MA · 01441-0001 · USA S4906-0003-8 5/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. Wall Mount Installation Reference Ceiling Mount S/V Installation Reference and Tile Bridge Dimensions