HomeMy WebLinkAboutA18-0060_approved documents_1538681615.pdf75 South Frontage Road West, Vail, CO 81657 Office: 970.479.2139 Inspections: inspections@vailgov.com Fire - Construction Permit A18-0060 Issued: 10/04/2018 TOWN OF VAIL Property Information Address: 200 VAIL RD ( 210108224999 ) Unit #: Parcel Number: 210108224999 Legal Description: Contacts Contact Type: Applicant Full Name: Greg Mikevich Address: 14200 exposition Ave Exposition Ave Aurora, CO 80012 Phone: 3038885535 Contact Type: Property Owner Full Name: Lodge Tower Common Area Address: CO Phone: None Contractor Contractor Type: General Company: Johnson Controls Security Solutions LLC State License #: Phone: 561-226-8210 Project Information Project Name: Lodge Tower Elevator Alarm 2018 Project Description: UPGRADE FIRE ALARM SYSTEM INTERFACE WITH ELEVATOR CONTROLS TO SUPPORT ELEVATOR MODERNIZATION Fees Paid Account #: 001-0000.31111.00 - Fire Alarm Permit Fee Fee Amount:$270.00 Account #: 001-0000.31123.00 - Fire Alarm Review Fee Fee Amount:$288.00 Total Paid:$558.00 Conditions Issued By: Town of Vail Fire and Emergency Services Department NOTICE: By issuance of this Permit the applicant agrees to comply to all Titles of the Town of Vail Code and all applicable State and Federal law. Failure to do so will void this Permit and the applicant shall forfeit all applicable fees. Johnson Controls 14200 E. Exposition Ave. Aurora, Colorado 80012 www.simplexgrinnell.com Tele: (303) 355-0500 Fax: (303) 355-0615 Prepared for: E.M.C.C. P.O Box 4555 Eagle, CO 81631 Fire Alarm Product Data Submittal for: Lodge Tower East Elevator Upgrade 200 Vail Road Vail, CO 81657 PROJECT: Lodge Tower East Elevator Upgrade PREPARED FOR: E.M.C.C. TYPE: DESCRIPTION: 4098-9714 PHOTO SENSOR 4098-9733 HEAT SENSOR 4098-9792 SENSOR BASE 4090-9002 RELAY IAM 2088-9021 ENCAPSULATED RELAY PAM-1 4090-9118 RLY IDNET 2 IAM W/T SENSE Fax: (303) 355-0615 14200 E. Exposition Ave. Aurora, CO 80012 Sales: (303) 355-0500 Service: (303) 355-0500 Features TrueAlarm analog sensing provides:  Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simplex® products:  4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details)  4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides:  Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection  Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity  Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot  Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide:  Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide:  Three fixed temperature sensing thresholds: 135° F, 155° F and 190° F  Rate-of-rise temperature sensing  Utility temperature sensing  Listed to UL 521 and ULC-S530 General features:  Operation is for ceiling or wall mounting  Listed to UL 268 and ULC-S529  Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted  Designed for EMI compatibility  Magnetic test feature is provided  Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference:  For isolator bases, refer to data sheet S4098-0025  For sounder bases, refer to data sheet S4098-0028  For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor’s present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor’s average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base’s LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base’s LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors – Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories S4098-0019-23 8/2017 ALARM Sensor Base Features Base mounted address selection:  Address remains with its programmed location  Accessible from front (DIP switch under sensor) General features:  Automatic identification provides default sensitivity when substituting sensor types  Integral red LED for power-on (pulsing), or alarm or trouble (steady on)  Locking anti-tamper design mounts on standard outlet box Magnetically operated functional test Sensor Bases 4098-9792, Standard Sensor Base 4098-9789, Sensor Base with wired connections for:  2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT):  4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC  4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required  Supervised relay operation is programmable and can be manually operated from control panel  Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Sensor Base Options 2098-9737, Remote or local mount supervised relay:  DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay:  SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay:  Activates when base LED is on steady, indicating local alarm or trouble  DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate:  Required for surface or semi-flush mounting to 4” square electrical box and for surface mounting to 4” octagonal box  Can be used for cosmetic retrofitting to existing 6-3/8” diameter base product 2098-9808, Remote red LED Alarm Indicator:  Mounts on single gang box (shown in illustration to right) Description TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor’s output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. Mounting Reference Electrical Box Requirements: (boxes are by others) Without relay in the box: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With relay in the box : 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 4-7/8" (124 mm) 15/16" (24 mm) 6-3/8" (162 mm) 1/4" (6.4 mm) 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and 4" square flush box 2098-9737 Supervised Relay (mounts in base electrical box or remotely) 4098-9822 Relay(mounts in base electrical box) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. Relay Size: 2-1/2" X 1-1/2" X 1" (3.75 in 3 ) (64 mm X 38 mm X 25.4 mm) 4098-9860 Supervised Relay (mounts in base electrical box or remotely; 2-3/8" X 1-1/4" X 11/32" (1 in 3 ) (60.4 mm X 31.8 mm X 8.6 mm) Surface mount reference 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 1-1/2" (38 mm) minimum box depth 2 S4098-0019-23 8/2017 TrueAlarm Sensor Bases and Accessories TrueAlarm Sensors Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors:  Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation  Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135° F / 190° F* (57.2° C / 88° C) 60 ft x 60 ft (18.3 m) 20 ft x 20 ft (6.1 m) for fixed temperature only; RTI = Quick 50 ft x 50 ft (15.2 m) for fixed temperature with either rate-of-rise selection; RTI = Ultra Fast 155° F (68° C) 40 ft x 40 ft (12.2 m) *Note: 190° F (88° C) ratings apply only to the 4098-9734 sensor. Smoke Sensors:  Photoelectric technology sensing  360° smoke entry for optimum response  Built-in insect screens 4098-9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 2-1/8" (54 mm) LED status indicator 4-7/8" (124 mm) 4098-9714 Photoelectric Sensor with Base 4098-9733 and 4098-9734 Heat Sensors TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). The 4098-9734 sensor provides an additional 190° F (88° C) set point. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. 2-3/8" (60 mm) LED status indicator 4-7/8" (124 mm) 4098-9733 Heat Sensor with Base 4098-9734 High Temperature Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Application Reference Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-23 8/2017 TrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model* Color Description Compatibility Mounting Requirements 4098-9792 White Standard Sensor Base No options 4” octagonal or 4” square box, 1-1/2” min. depth; or single gang box, 2” min. depth4098-9776 Black 4098-9789 White Sensor Base with connections for Remote LED Alarm Indicator or Unsupervised Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 4” octagonal or 4” square box Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. ** NOTE: 4098-9791 and 4098- 9780 are NOT compatible with the 2120 CDT 4098-9789 IND White 4098-9775 Black 4098-9791** White 4-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 2098-9737 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 4098-9780** White 2-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 4098-9860 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay TrueAlarm Sensors Model* Model* Description Compatibility Mounting Requirements 4098-9714 White Photoelectric Smoke Sensor Bases 4098-9775, 4098-9776, 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Refer to base requirements 4098-9714 IND 4098-9774 Black 4098-9733 White Heat Sensor 4098-9734 White High Temperature Heat Sensor TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base electrical box For use with 4098-9791 base Remote Mounting requires 4” octagonal or 4” square box, 1-1/2” minimum depth Base Mounting requires 4” octagonal box, 2- 1/8” deep with 1-1/2” extension ring4098-9860 Supervised Relay, mounts remote or in base electrical box For use with 4098-9780 base 2098-9808 Remote Red LED Alarm Indicator on single gang stainless steel plate Bases 4098-9789, 4098-9791, and 4098- 9780 Single gang box, 1-1/2” minimum depth 4098-9822 Unsupervised Relay, tracks base LED status; Note: Mounts only in base electrical box Bases 4098-9789, 4098-9791, and 4098- 9780 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring 4098-9832 Adapter Plate Bases 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Required for surface or semi-flush mounted 4” square box and for surface mounted 4” octagonal box * Note: Model numbers ending in IND are assembled in India. SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Westminster, MA • 01441-0001 • USA S4098-0019-23 8/2017 www.simplex-fire.com © 2017 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Operating Temperature Range 32° to 100° F (0° to 38° C) Operating Temperature Range with 4098-9733 Heat Sensor 32° to 122° F (0° to 50° C) with 4098-9714 Smoke Sensor 15° to 122° F (-9° to 50° C) With 4098-9734 Heat Sensor 32° to 150° F (0° to 66° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/min (0-1220 m/min) Housing Color Frost White or Black 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 A, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TrueAlarm Analog Sensing Product Selection Chart Specifications Features TrueAlarm analog sensing provides:  Digital transmission of analog sensor values via IDNet or MAPNET II two-wire communications For use with the following Simplex® products:  4007ES, 4010, 4010ES, 4100ES, and 4100U Series control panels; and 4008 Series control panels with reduced feature set (refer to data sheet S4008-0001 for details)  4020, 4100, and 4120 Series control panels, Universal Transponders, and 2120 TrueAlarm CDTs equipped for MAPNET II operation Fire alarm control panel provides:  Peak value logging allowing accurate analysis of each sensor for individual sensitivity selection  Sensitivity monitoring satisfying NFPA 72 sensitivity testing requirements; automatic individual sensor calibration check verifies sensor integrity  Automatic environmental compensation, multi-stage alarm operation, and display of sensitivity directly in percent per foot  Ability to display and print detailed sensor information in plain English language Photoelectric smoke sensors provide:  Seven levels of sensitivity from 0.2% to 3.7% (refer to additional information on page 3) Heat sensors provide:  Three fixed temperature sensing thresholds: 135° F, 155° F and 190° F  Rate-of-rise temperature sensing  Utility temperature sensing  Listed to UL 521 and ULC-S530 General features:  Operation is for ceiling or wall mounting  Listed to UL 268 and ULC-S529  Louvered smoke sensor design enhances smoke capture by directing flow to chamber; entrance areas are minimally visible when ceiling mounted  Designed for EMI compatibility  Magnetic test feature is provided  Different bases are available to support a supervised or unsupervised output relay, and/or a remote LED alarm indicator Additional base reference:  For isolator bases, refer to data sheet S4098-0025  For sounder bases, refer to data sheet S4098-0028  For photo/heat sensors, refer to data sheet S4098-0024 (single address) and S4098-0033 (dual address) * These products have been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listings 7272-0026:218, 7271-0026:231, 7270-0026:216, and 7300-0026:217 for allowable values and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable, contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4098-9714 TrueAlarm Photoelectric Sensor Mounted in Base Description Digital Communication of Analog Sensing. TrueAlarm analog sensors provide an analog measurement digitally communicated to the host control panel using Simplex addressable communications. At the control panel, the data is analyzed and an average value is determined and stored. An alarm or other abnormal condition is determined by comparing the sensor’s present value against its average value and time. Intelligent Data Evaluation. Monitoring each sensor’s average value provides a continuously shifting reference point. This software filtering process compensates for environmental factors (dust, dirt, etc.) and component aging, providing an accurate reference for evaluating new activity. With this filtering, there is a significant reduction in the probability of false or nuisance alarms caused by shifts in sensitivity, either up or down. Control Panel Selection. Peak activity per sensor is stored to assist in evaluating specific locations. The alarm set point for each TrueAlarm sensor is determined at the host control panel, selectable as more or less sensitive as the individual application requires. Timed/Multi-Stage Selection. Sensor alarm set points can be programmed for timed automatic sensitivity selection (such as more sensitive at night, less sensitive during day). Control panel programming can also provide multi-stage operation per sensor. For example, a 0.2% level may cause a warning to prompt investigation while a 2.5% level may initiate an alarm. Sensor Alarm and Trouble LED Indication. Each sensor base’s LED pulses to indicate communications with the panel. If the control panel determines a sensor is in alarm, or is dirty or has some other type of trouble, the details are annunciated at the control panel and that sensor base’s LED will be turned on steadily. During a system alarm, the control panel will control the LEDs such that an LED indicating a trouble will return to pulsing to help identify the alarmed sensors. TrueAlarm Analog Sensing UL, ULC, CSFM Listed; FM Approved; TrueAlarm Analog Sensors – Photoelectric MEA (NYC) Acceptance* and Heat; Standard Bases and Accessories S4098-0019-23 8/2017 ALARM Sensor Base Features Base mounted address selection:  Address remains with its programmed location  Accessible from front (DIP switch under sensor) General features:  Automatic identification provides default sensitivity when substituting sensor types  Integral red LED for power-on (pulsing), or alarm or trouble (steady on)  Locking anti-tamper design mounts on standard outlet box  Magnetically operated functional test Sensor Bases 4098-9792, Standard Sensor Base 4098-9789, Sensor Base with wired connections for:  2098-9808 Remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Supervised Relay Bases (not compatible with 2120 CDT):  4098-9791, 4-Wire Sensor Base, use with remote or locally mounted 2098-9737 relay, requires separate 24 VDC  4098-9780, 2-Wire Sensor Base, use with remote or locally mounted 4098-9860 relay, no separate power required  Supervised relay operation is programmable and can be manually operated from control panel  Includes wired connections for remote LED alarm indicator or 4098-9822 relay (relay is unsupervised and requires separate 24 VDC) Sensor Base Options 2098-9737, Remote or local mount supervised relay:  DPDT contacts for resistive/suppressed loads, power limited rating of 3 A @ 28 VDC; non-power limited rating of 3 A @ 120 VAC (requires external 24 VDC coil power) 4098-9860, Remote or local mount supervised relay:  SPDT dry contacts, power limited rating of 2 A @ 30 VDC, resistive; non-power limited rating of 0.5 A @ 125 VAC, resistive 4098-9822, LED Annunciation Relay:  Activates when base LED is on steady, indicating local alarm or trouble  DPDT contacts for resistive/suppressed loads, power limited rating of 2 A @ 28 VDC; non-power limited rating of 1/2 A @ 120 VAC, (requires external 24 VDC coil power) 4098-9832, Adapter plate:  Required for surface or semi-flush mounting to 4” square electrical box and for surface mounting to 4” octagonal box  Can be used for cosmetic retrofitting to existing 6-3/8” diameter base product 2098-9808, Remote red LED Alarm Indicator:  Mounts on single gang box (shown in illustration to right) Description TrueAlarm sensor bases contain integral addressable electronics that constantly monitor the status of the detachable photoelectric or heat sensors. Each sensor’s output is digitized and transmitted to the system fire alarm control panel every four seconds. Since TrueAlarm sensors use the same base, different sensor types can be easily interchanged to meet specific location requirements. This feature also allows intentional sensor substitution during building construction. When conditions are temporarily dusty, instead of covering the smoke sensors (causing them to be disabled), heat sensors may be installed without reprogramming the control panel. Although the control panel will indicate an incorrect sensor type, the heat sensor will operate at a default sensitivity providing heat detection for building protection at that location. Mounting Reference Electrical Box Requirements: (boxes are by others) Without relay in the box: 4" octagonal or 4" square, 1-1/2" deep; single gang, 2" deep With relay in the box : 4" octagonal or 4" square, 1-1/2" deep, with 1-1/2" extension ring TrueAlarm Bases 4098-9780, 4098-9789, 4098-9791, & 4098-9792 4-7/8" (124 mm) 15/16" (24 mm) 6-3/8" (162 mm) 1/4" (6.4 mm) 4098-9832 Adapter Plate, required for mounting to surface mounted boxes and 4" square flush box 2098-9737 Supervised Relay (mounts in base electrical box or remotely) 4098-9822 Relay(mounts in base electrical box) NOTE: Review total wire count, wire size, and accessories being wired to determine required box volume. Relay Size: 2-1/2" X 1-1/2" X 1" (3.75 in 3 ) (64 mm X 38 mm X 25.4 mm) 4098-9860 Supervised Relay (mounts in base electrical box or remotely; 2-3/8" X 1-1/4" X 11/32" (1 in 3 ) (60.4 mm X 31.8 mm X 8.6 mm) Surface mount reference 4" (102 mm) Square Box 4" (102 mm) Octagonal Box Flush mount reference, mount even with final surface, or with up to 1/4" (6.4 mm) maximum recess 1-1/2" (38 mm) minimum box depth 2 S4098-0019-23 8/2017 TrueAlarm Sensor Bases and Accessories TrueAlarm Sensors Features Sealed against rear air flow entry Interchangeable mounting EMI/RFI shielded electronics Heat sensors:  Selectable rate compensated, fixed temperature sensing with or without rate-of-rise operation  Rated spacing distance between sensors: Fixed Temp. Setting UL & ULC Spacing FM Spacing, Either Fixed Temperature Setting 135° F / 190° F* (57.2° C / 88° C) 60 ft x 60 ft (18.3 m) 20 ft x 20 ft (6.1 m) for fixed temperature only; RTI = Quick 50 ft x 50 ft (15.2 m) for fixed temperature with either rate-of-rise selection; RTI = Ultra Fast 155° F (68° C) 40 ft x 40 ft (12.2 m) *Note: 190° F (88° C) ratings apply only to the 4098-9734 sensor. Smoke Sensors:  Photoelectric technology sensing  360° smoke entry for optimum response  Built-in insect screens 4098-9714 Photoelectric Sensor TrueAlarm photoelectric sensors use a stable, pulsed infrared LED light source and a silicon photodiode receiver to provide consistent and accurate low power smoke sensing. Seven levels of sensitivity are available for each individual sensor, ranging from 0.2% to 3.7% per foot of smoke obscuration. Sensitivities of 0.2%, 0.5%, and 1% are for special applications in clean areas. Standard sensitivities are 1.5%, 2.0%, 2.5%, 3.0%, and 3.7%. Application type and sensitivity are selected and then monitored at the fire alarm control panel.* The sensor head design provides 360° smoke entry for optimum response to smoke from any direction. Due to its photoelectric operation, air velocity is not normally a factor, except for impact on area smoke flow. 2-1/8" (54 mm) LED status indicator 4-7/8" (124 mm) 4098-9714 Photoelectric Sensor with Base 4098-9733 and 4098-9734 Heat Sensors TrueAlarm heat sensors are self-restoring and provide rate compensated, fixed temperature sensing, selectable with or without rate-of-rise temperature sensing. Due to its small thermal mass, the sensor accurately and quickly measures the local temperature for analysis at the fire alarm control panel. Rate-of-rise temperature detection is selectable at the control panel for either 15° F (8.3° C) or 20° F (11.1° C) per minute. Fixed temperature sensing is independent of rate-of-rise sensing and programmable to operate at 135° F (57.2° C) or 155° F (68° C). The 4098-9734 sensor provides an additional 190° F (88° C) set point. In a slow developing fire, the temperature may not increase rapidly enough to operate the rate-of-rise feature. However, an alarm will be initiated when the temperature reaches its rated fixed temperature setting. TrueAlarm heat sensors can be programmed as a utility device to monitor for temperature extremes in the range from 32° F to 155° F (0° C to 68° C). This feature can provide freeze warnings or alert to HVAC system problems. Refer to specific panels for availability. 2-3/8" (60 mm) LED status indicator 4-7/8" (124 mm) 4098-9733 Heat Sensor with Base 4098-9734 High Temperature Heat Sensor with Base WARNING: In most fires, hazardous levels of smoke and toxic gas can build up before a heat detection device would initiate an alarm. In cases where Life Safety is a factor, the use of smoke detection is highly recommended. Application Reference Sensor locations should be determined only after careful consideration of the physical layout and contents of the area to be protected. Refer to NFPA 72, the National Fire Alarm and Signaling Code. On smooth ceilings, smoke sensor spacing of 30 ft (9.1 m) may be used as a guide.* * For detailed application information including sensitivity selection, refer to Installation Instructions 574-709. 3 S4098-0019-23 8/2017 TrueAlarm Sensor Bases (for use with Sensors 4098-9714 and 4098-9733) (Refer to Application Manual 574-709 and Installation Instructions 574-707 for additional information) Model* Color Description Compatibility Mounting Requirements 4098-9792 White Standard Sensor Base No options 4” octagonal or 4” square box, 1-1/2” min. depth; or single gang box, 2” min. depth4098-9776 Black 4098-9789 White Sensor Base with connections for Remote LED Alarm Indicator or Unsupervised Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 4” octagonal or 4” square box Note: Box depth requirements depend on total wire count and wire size, refer to accessories list below for reference. ** NOTE: 4098-9791 and 4098- 9780 are NOT compatible with the 2120 CDT 4098-9789 IND White 4098-9775 Black 4098-9791** White 4-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 2098-9737 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay 4098-9780** White 2-Wire Sensor Supervised Relay Base with connections for LED Indicator or Unsupervised Relay 4098-9860 Supervised Remote Relay 2098-9808 Remote Alarm Indicator or 4098-9822 Unsupervised Relay TrueAlarm Sensors Model* Model* Description Compatibility Mounting Requirements 4098-9714 White Photoelectric Smoke Sensor Bases 4098-9775, 4098-9776, 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Refer to base requirements 4098-9714 IND 4098-9774 Black 4098-9733 White Heat Sensor 4098-9734 White High Temperature Heat Sensor TrueAlarm Sensor/Base Accessories Model Description Compatibility Mounting Requirements 2098-9737 Supervised Relay, mounts remote or in base electrical box For use with 4098-9791 base Remote Mounting requires 4” octagonal or 4” square box, 1-1/2” minimum depth Base Mounting requires 4” octagonal box, 2- 1/8” deep with 1-1/2” extension ring4098-9860 Supervised Relay, mounts remote or in base electrical box For use with 4098-9780 base 2098-9808 Remote Red LED Alarm Indicator on single gang stainless steel plate Bases 4098-9789, 4098-9791, and 4098- 9780 Single gang box, 1-1/2” minimum depth 4098-9822 Unsupervised Relay, tracks base LED status; Note: Mounts only in base electrical box Bases 4098-9789, 4098-9791, and 4098- 9780 4” octagonal box, 2-1/8” deep with 1-1/2” extension ring 4098-9832 Adapter Plate Bases 4098-9792, 4098-9789, 4098-9791, and 4098-9780 Required for surface or semi-flush mounted 4” square box and for surface mounted 4” octagonal box * Note: Model numbers ending in IND are assembled in India. SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. NFPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association (NFPA). Westminster, MA • 01441-0001 • USA S4098-0019-23 8/2017 www.simplex-fire.com © 2017 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. General Operating Specifications Communications and Sensor Supervisory Power IDNet or MAPNET II communications, auto-selected, 1 address per base Communications Connections Screw terminals for in/out wiring, 18 to 14 AWG (0.82 mm2 to 2.08 mm2) Remote LED Alarm Indicator Current 1 mA typical, no impact to alarm current Remote LED Alarm Indicator and Relay Connections Color coded wire leads, 18 AWG (0.82 mm2 ) UL Listed Operating Temperature Range 32° to 100° F (0° to 38° C) Operating Temperature Range with 4098-9733 Heat Sensor 32° to 122° F (0° to 50° C) with 4098-9714 Smoke Sensor 15° to 122° F (-9° to 50° C) With 4098-9734 Heat Sensor 32° to 150° F (0° to 66° C) Storage Temperature Range 0° F to 140° F (-18° C to 60° C) Humidity Range 10 to 95% RH 4098-9714 Smoke Sensor Air Velocity Rating 0-4000 ft/min (0-1220 m/min) Housing Color Frost White or Black 4098-9791 Base With Supervised Remote Relay 2098-9737 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current 270 A, from 24 VDC supply Alarm Current with 2098-9737 Relay 28 mA, from 24 VDC supply 4098-9780 Base With Supervised Remote Relay 4098-9860 (see page 2 for contact ratings) Power Supplied from communications 4098-9822 Unsupervised Relay, Requirements for Bases 4098-9789. 4098-9791, and 4098-9780 (see page 2 for contact ratings) Externally Supplied Relay Coil Voltage 18-32 VDC (nominal 24 VDC) Supervisory Current Supplied from communications Alarm Current 13 mA from separate 24 VDC supply TrueAlarm Analog Sensing Product Selection Chart Specifications Features Individual Addressable Relay Module (Relay IAM):  IDNet addressable control for use with Simplex® fire alarm control panel models 4007ES, 4008, 4010, 4010ES, 4100ES, and 4100U  A single addressable point provides control and status tracking of a Form “C” contact  Low power latching relay design allows IDNet communications to supply both data and module power  Relay is set to OFF on initial power up and upon loss of IDNet communications Compact, sealed construction:  Enclosed design minimizes dust infiltration  Mounts in standard 4” (102 mm) square electrical box, optional adapter bracket is available to mount in a 4 11⁄16” (119 mm) square electrical box  Screw terminals for wiring connections  Visible LED flashes to indicate communications  Optional covers are available to allow LED to be viewed after installation UL listed to Standard 864 Description IDNet Relay IAMs allow fire alarm control panels to control a remotely located Form “C” contact using IDNet addressable communications for both data and module power. Typical applications would be for switching local power for control functions such as elevator capture, or control of HVAC components, pressurization fans, dampers, etc. Relay status is also communicated requiring only one device address. Product Selection Model Description 4090-9002 Relay IAM Optional Adapter and Trim Plates Model Description 4090-9813 Adapter plate to fit 4 11®16” (119 mm) square electrical box 4090-9801 For semi-flush mounted box Trim Plate, galvanized steel, with LED viewing window; includes mounting screws4090-9802 For surface mounted box * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:223 for allowable values and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. 4090-9002 IDNet Relay IAM Package (shown approximately 1/2 size) Specifications Communications IDNet communications, 1 address per device Relay IAM Power Supplied by IDNet communications Contact Ratings* (not rated for incandescent switching) Type Form C, SPDT Power-Limited 2 A @ 24 VDC, resistive from listed fire alarm supply1 A @ 24 VDC, inductive Nonpower-Limited 0.5 A @ 120 VAC, resistive * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120 VAC loads may require RC networks or varistors, depending on device type. Refer to the installation instructions for additional information. Wire Connections Screw terminals for in/out wiring, 18 to 14 AWG wire (0.82 to 2.08 mm2) IDNet Communications Wiring Reference Up to 2500 ft (762 m) from control panel Up to 10,000 ft (3048 m) total wiring distance (including T-Taps) Compatible with Simplex 2081-9044 Overvoltage Protectors Dimensions 4 ⅛” H x 4 ⅛” W x 1 ⅜” D (105 mm x 105 mm x 35 mm) Housing Material Black thermoplastic Mounting Plate Sheet metal, galvanized Temperature Range 32° to 120° F (0° to 49° C), intended for indoor operation Humidity Range Up to 93% RH at 100° F (38° C) Installation Instructions 574-184 Multi-Application Peripherals UL, ULC, CSFM Listed; FM Approved; IDNet Communicating Devices MEA (NYC) Acceptance* Model 4090-9002 Relay IAM S4090-0002-10 11/2014 TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Tyco Fire Protection Products · Westminster, MA · 01441-0001 · USA S4090-0002-10 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) 4090-9002 Relay IAM Address setting under resealable label Optional Trim Plates for Visible LED 4090-9802, Trim plate for surface mounted box 4090-9801, Trim plate for semi-flush mounted box Mounting Reference, Double Gang Blank Cover Plate 4-9/16" (116 mm) 4-9/16" (116 mm) 4-5/16" (109 mm) Light pipe for LED viewing 4-5/16" (109 mm) Relay IAM Mounting Information Features UL listed under Standard 864 as Control Unit Accessory (UOXX) Track mount package availability:  Single relay module or four relay module, with or without cover, with SPDT or DPDT contacts  LED indicates relay module status  Cover provide status LED viewing ports  Multiple coil voltage inputs, diode polarized for DC  Modules are track mounted with snap-apart feature design allowing the four relay module to be separated Single encapsulated SPDT relay package with color coded 18 AWG wire leads, available in two versions:  2088-9021 (PAM-1) Provides diode polarized multiple input voltage ability and LED indication  4098-9843 (PAM-SD) Provides a diode polarized 24 VDC coil with in/out wiring Description These multi-purpose control relays offer SPDT or DPDT, 10 A (or 7 A) contacts in a variety of mechanical packages. Models are available for coil operation by one of four input voltages allowing a single relay to be energized from a voltage source of 18-35 VDC or VAC, 120 VAC, or 230 VAC (not available with 4098-9843). Voltage selection is made by wiring to the appropriate input terminals or wire leads. Each relay model (except model 4098-9843) contains a red LED which indicates that the relay is energized. Mounting options are varied for application flexibility. Track mounted relays may be “snapped apart” from a standard four-module assembly and used independently if desired. Specifications Track Mount Relays, see page 2 for dimensions Coil Voltage 18-35 VAC/VDC, 120, or 230 VAC Coil Current SPDT models = 18 mA DPDT models = 40 mA Terminal Blocks Up to 14 AWG (2.08 mm2 ) Contact Ratings 10 A @ 120 VAC N.O. rated 1/6 HP, N.C. rated 1/8 HP 7A @ 28 VDC and @ 230 VAC Temperature Ratings UL Listed Range 32° F to 120° F (0° C to 49° C) Humidity 85% RH Non-condensing NC C NONC C NO NC C NONC C NO ON T1D2 + C1 0 18/24 115 230 R2 R1 NC C NONC C NO NC C NONC C NO ON T1D2 + C1 0 18/24 115 230 R2 R1 NC C NONC C NO NC C NONC C NO ON T1D2 + C1 0 18/24 115 230 R2 R1 NC C NONC C NO NC C NONC C NO ON T1D2 + C1 0 18/24 115 230 R2 R1 2088-9020, MR204/C, Four DPDT Relay Package with Enclosure (shown with cover removed) AP&C-PAM SD WHT BLU YEL RED ORG Encapsulated Relay Package (typical of 2088-9021, PAM-1 and 4098-9843, PAM-SD) Specifications Continued Encapsulated Relays, see page 2 for dimensions Connections 18 AWG (0.82 mm2 ) color-coded wire leads Relay 2088-9021 Contact Ratings 10 A @ 120 VAC, resistive Coil Ratings Voltage 18-35 VAC/VDC, 120, or 240 VAC Current 15 mA @ 24 VAC/VDC, & @ 120 or 230 VAC Relay 4098-9843 Coil Ratings 18-32 VDC input, polarized, 15 mA @ 24 VDC Contact Ratings 7 A at 0.35 p.f @ 28 VDC & 120 VAC 250 µA @ 5 VDC Temperature Ratings UL Listed Range 32° F to 120° F (0° C to 49° C) Humidity 100% RH, condensing * Listings are under Apollo America Inc. per model numbers shown on page 2. See CSFM Listing 7300-1004:0101 for allowable values and/or conditions concerning material presented in this document. System Accessories UL, CSFM Listed; Fire Alarm Control Relays, Track Mount and MEA (NYC) Acceptance* Encapsulated; Model 4098-9843 and 2088 Series S2088-0010-10 11/2014 Module Positions Reference Number Model Number Relay Type Packaging Dimensions One 2088-9007 MR-101/T SPDT Track mount, without cover 3-1/4” H x 2-1/8” W x 1-1/2” D (83 mm x 54 mm x 38 mm)2088-9009 MR-201/T DPDT 2088-9008 MR-101/C SPDT Track mount with cover 5-1/8” H x 3-1/8” W x 2-1/2” D (131 mm x 79 mm x 64 mm)2088-9010 MR-201/C DPDT Four 2088-9017 MR-104/T SPDT Track mount, without cover 3-1/4” H x 8-1/2” W x 1-1/2” D (83 mm x 216 mm x 38 mm)2088-9019 MR-204/T DPDT 2088-9018 MR-104/C SPDT Track mount with cover 5-1/8” H x 9-1/2” W x 2-1/2” D (131 mm x 241 mm x 64 mm)2088-9020 MR-204/C DPDT NA 2088-9021 PAM-1 SPDT Encapsulated, multi-voltage coil, color coded 18 AWG (0.82 mm2 ) wire leads, with coil status LED 1-1/2” H x 1” W x 7/8” D (38 mm x 25.4 mm x 22 mm) 4098-9843 PAM-SD Encapsulated, 24 VDC coil, color coded 18 AWG (0.82 mm2 ) wire leads (no LED) 1-1/2” H x 1-3/16” W x 13/16” D (38 mm x 30 mm x 21 mm) NC C NO Coil voltage (note polarity for DC) (-) (+) AC AC N V V V (18-35) VDC (18-35) VAC 120 VAC 230 VAC 0 18/24 115 230 SPDT contacts rated 10 A @ 120 VAC, resistive NC C NO (-) (+) AC AC N V V V (18-35) VDC (18-35) VAC 120 VAC 230 VAC 0 18/24 115 230 DPDT contacts rated 10 A @ 120 VAC, resistive NC C NO Terminal strip connections SPDT models Relay energized LED Coil voltage (note polarity for DC) Terminal strip connections DPDT models Tyco Fire Protection Products · Westminster, MA · 01441-0001 · USA S2088-0010-10 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Relay Selection Chart Track Mount Relay Wiring Reference Features Dual point operation provides a supervised multi-state input and a relay output in a single package using only one address:  Typical applications are for damper motor control with dual damper position feedback monitoring (open and closed)  For use with Simplex® 4007ES, 4010ES, 4100ES, or 4100U Fire Alarm Control Panels providing IDNet communications (4100U requires software revision 11 or higher) Input/Output details:  Input operation is “T-Sense” and provides supervised monitoring of normally open, dry contacts  Status conditions are Normal, Open Circuit (trouble condition), Current Limited (position input 1), and Short (position input 2)  Total wiring distance to supervised contacts is up to 500 ft (152 m); for indoor wiring applications  Low power latching relay design allows IDNet communications to supply both data and module power  Relay is set to OFF on initial power up and upon loss of IDNet communications  Form C relay output is rated 2 A @ 30 VDC, and 0.5 A @ 120 VAC (resistive ratings) Compact, sealed construction:  Enclosed design minimizes dust infiltration  Mounts in standard 4” square electrical box  Visible LED flashes to indicate communications  Screw terminals for wiring connections  Optional covers are available to allow LED to be viewed after installation UL Listed to Standard 864 Description Single Address Dual Point Module. The 4090-9118 Relay IAM with T-Sense allows a compatible Simplex fire alarm control panel IDNet communication channel to monitor two input contact closures with one point and control an output relay with the other point, both from a compact module requiring a single address. Module power is supplied from the IDNet communications channel eliminating the need for separate power wiring. Multi-Point Device Description. The input circuit and relay operation are controlled independently and may be disabled separately. Point association is determined at the host panel. At the host panel display, the device address is designated as a single hardware location (such as 1-1). The individual points are considered “sub-points” and are layered underneath (such as 1-1-1 and 1-1-2). 4090-9118 Relay IAM with T-Sense Input (shown approximately 1/2 size) T-Sensing Operation Supervised Input. The 4090-9118 Relay IAM with T-Sense has a supervised input that monitors for continuity to an end-of-line resistor and can differentiate between a short circuit contact closure and a current limited contact closure. Four State Operation. Normal is when all contacts are open and there is continuity to the end-of-line resistor; Open is when continuity does not exist to the end-of-line resistor, causing a Trouble condition; Short, indicates that a contact has closed that is directly connected to the input circuit; and Current Limited indicates that a contact has closed beyond a series connected current limiting resistor. This operation allows differentiation between two different contact types due to their wiring location, and reporting as a single IDNet addressable point to the fire alarm control panel. Typical Applications Efficient Package. For smoke control applications, this module provides an efficient package for fan damper control with position feedback. The monitor point can be connected to two separate status indicator switches allowing the host panel to track the fan damper status with respect to the requested fan control operation. General Applications. The monitor and control points can be applied for a variety of associated or independent operations. Flexible programming abilities at the host panel can provide the association logic required for a wide variety of fire or utility operations. * This product has been approved by the California State Fire Marshal (CSFM) pursuant to Section 13144.1 of the California Health and Safety Code. See CSFM Listing 7300-0026:311 for allowable values and/or conditions concerning material presented in this document. Accepted for use – City of New York Department of Buildings – MEA35-93E. Additional listings may be applicable; contact your local Simplex product supplier for the latest status. Listings and approvals under Simplex Time Recorder Co. are the property of Tyco Fire Protection Products. Multi-Point Peripherals UL, ULC, CSFM Listed; FM Approved; 4090-9118 Relay IAM (Individual MEA (NYC) Acceptance* Addressable Module) with T-Sense Input S4090-0007-6 11/2014 Model Description 4090-9118 Relay IAM with T-Sense Optional Adapter and Trim Plates Model Description 4090-9813 Adapter plate to fit 4 11⁄16” (119 mm) square electrical box 4090-9801 For semi-flush mounted box Trim Plate, galvanized steel, with LED viewing window; includes mounting screws4090-9802 For surface mounted box End-of-Line Resistor Harnesses (ordered separately as required) Model Reference No. Description 4081-9003 733-896 4.7 k, 1/2 W Use for current limited monitoring, refer to diagram below4081-9005 733-984 1.8 k, 1/2 W Common Circuit Status Modes Circuit Status Device Status Panel Display Normal Switches open Normal Open circuit Wiring discontinuity Trouble Damper Position Monitoring Status Modes Circuit Status Device Status Typical Panel Display Short Switch A closed Damper Closed Current Limited Switch B closed Damper Open Waterflow and Tamper Switch Monitoring Status Modes Circuit Status Device Status Panel Display Short Waterflow switch closed Fire Alarm Current Limited Tamper switch closed Supervisory IDNet communications from host control panel T-Sense Input 4090-9118 Relay IAM with T-Sense 1.8 k, 1/2 W + Maximum distance to contacts is 500 ft (152 m) (input is for indoor wiring only) IDNet Wiring Distances: 1. Up to 2500 ft (762 m) from host control panel. 2. Up to 10,000 ft (3048 m) total wiring distance, including "T" taps. NOTE: Refer to Installation Instructions 574-874 for detailed installation information. - + - Current limited contact Shorting contact To next device N.O. Com N.C. Output For Fire Alarm applications, locate loads within 3 ft (1 m) of contacts Power Limited Contact Ratings: 2 A @ 30 VDC, resistive loads 1 A @ 30 VDC, inductive loads Non-Power Limited Contact Ratings: 0.5 A @ 120 VAC, resistive loads 0.25 A @ 120 VAC, inductive loads (refer to specifications for additional information) 4.7 k /2 W End-of-line resistor 2 S4090-0007-6 11/2014 Product Selection T-Sense Input Operating Modes Wiring Reference 3 S4090-0007-6 11/2014 4" (102 mm) square box, 2-1/8" (54 mm) minimum depth, RACO 232 or equal (supplied by others) Double gang blank cover plate and mounting screws, for use when LED is not required to be externally viewed (supplied by others) 4090-9118 Relay IAM with "T" Sense Address setting under resealable label 4090-9802, Trim plate for surface mounted box 4090-9801, Trim plate for semi-flush mounted box Optional Trim Plates for Visible LED Mounting Reference, Double Gang Blank Cover Plate 4-9/16" (116 mm) 4-9/16" (116 mm) 4-5/16" (109 mm) Light pipe for LED viewing 4-5/16" (109 mm) Mounting Information Electrical Communications IDNet communications, one address Power Consumes one unit load, power supplied from a compatible IDNet communications channel Point Allocation Reference Point Type TRIAM I/O Point Usage per Panel 2; 1 for relay, 1 for input Public Points Usage up to 3; 1 for relay, 1 for input, 1 for trouble; for points mapped to the Fire Alarm Network Input Requirements Normally open dry contacts Up to 500 ft (152 m) total distance from Relay IAM For indoor wiring applications only Input Supervision Resistors Two required, refer to Installation Instructions 574-874 for additional information and wiring detail Wire Connections Screw terminals for input and output wiring, 18 to 14 AWG wire (0.82 mm2 to 2.08 mm2) Relay Contact Ratings* Form C (SPDT) (not rated for incandescent switching) Power-Limited 2 A @ 30 VDC, resistive from listed fire alarm supply1 A @ 30 VDC, inductive Nonpower-Limited 0.5 A @ 120 VAC, resistive 0.25 A @ 120 VAC, inductive * Provide circuit fusing and transient suppression as required per application. DC inductive loads can typically be diode suppressed; 120 VAC loads may require RC networks or varistors, depending on device type. Refer to Installation Instructions 574-874 for additional information. IDNet Wiring Distance Reference Up to 2500 ft (762 m) from the fire alarm control panel Up to 10,000 ft (3048 m) total Class B wiring distance including T-Taps Compatible with 2081-9044 Overvoltage Protectors Mechanical Dimensions 4-1/8” H x 4-1/8” W x 1-3/8” D (105 mm x 105 mm x 35 mm) Package Black thermoplastic housing on metal mounting plate Temperature 32° to 120° F (0° to 49° C) indoor operation only Humidity Range 10 to 90% RH at 90° F (32° C) Installation Instructions 574-874 Tyco Fire Protection Products · Westminster, MA · 01441-0001 · USA S4090-0007-6 11/2014 www.simplex-fire.com © 2014 Tyco Fire Protection Products. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice. TYCO, SIMPLEX, and the product names listed in this material are marks and/or registered marks. Unauthorized use is strictly prohibited. Specifications